Ademco 8DL5817CB-2 Wireless Commercial / Household Transmitter User Manual K5623V2 RevA ii
Honeywell International Inc. Wireless Commercial / Household Transmitter K5623V2 RevA ii
Ademco >
manual
FCC STATEMENTS Preliminary K5623V2 10/07 Rev. A ADEMCO 5817CB LIMITED WARRANTY Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 2 Corporate Center Drive, Melville, NY, 11747, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to your local authorized Honeywell representative. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. This device complies with Part 15 of FCC rules and RSS 210 of IC. Operation is subject to the following two conditions: (1) this device may not cause harmful interference. (2) this device must accept any interference received, including interference that may cause undesired operation. Note: The user shall not make any changes or modifications to the equipment unless authorized by the Installation and Setup Guide or User Guide. Unauthorized changes or modifications could void the user's authority to operate the equipment. UL For dry, indoor use only. Do not install in air-handling spaces. 2 Corporate Center Drive, Suite 100 P.O. Box 9040 Melville, NY 11747 ÊK5623V2PŠ K5623V2 10/07 Rev. A (Preliminary) Copyright © 2007 Honeywell International Inc. www.security.honeywell.com WIRELESS COMMERCIAL/ HOUSEHOLD TRANSMITTER INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The 5817CB is a universal contact-monitoring transmitter that can be used with household and commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations, and remote duct detectors. Upon activation, it emits an RF signal to a control panel that sends a burglary or fire alarm to a central station. The 5817CB has three unique input loops (zones). The first loop (primary loop) is supervised and typically used for high-priority alarm reporting such as commercial fire or burglary. It requires a 470K ohm end-of-line resistor to be placed across the sensor. The second loop is the built-in, normally closed reed switch (used in conjunction with a magnet, as described below). The third loop is another normally closed household burglary loop. All three loops may be used. A fourth (automatically enrolled) loop contains two tamper switches to protect the 5817CB transmitter. A built-in cover tamper switch is activated when the cover is removed. A unit tamper switch is activated if the unit is separated from its mounting plate. PROGRAMMING The 5817CB has its own unique serial number permanently assigned during manufacture. You must "enroll" this transmitter serial number in the control panel at some point prior to its usage in the alarm system. Refer to the control panel's installation instructions for specific programming procedure. Note: During programming of the control panel, program the 5817CB transmitter as Input Type "RF" (i.e., supervised RF) (mandatory for UL installations). MOUNTING For proper orientation of the unit in relation to its wall mounting plate and the loop wiring, read all of this section before installing the unit. Signal strength may vary from location to location. Before mounting the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength from this location. When a satisfactory location is found, make note of the position of the unit on the wall, remove the battery and proceed with installation. The following mounting instructions assume that the unit will be mounted as shown in the Figures. The unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting plate or tamper switch hold-down (if used), is maintained. The 5817CB is supplied with a tamper switch hold-down tab (connected to the mounting plate as shown in Figure 1), for use when the wall mounting plate is not needed. Remove the tab with diagonal cutting pliers. The mounting plate, installed as described below, enables easy removal of the unit for servicing, should it become necessary. 1. Remove the transmitter's cover by inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit on the right side closest to the cover's decorative ribs and twisting. 2. Disengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the mounting plate release hole (see Figure 3) and pushing the locking tab out (see Figure 1). Slide the mounting plate downward along the case back. Note: For this application, the alignment guide strip along one edge of the mounting plate serves no function and may be broken away, if desired. 3. If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at one corner of the mounting plate (and/or case back). Surface wiring is discussed in Step 5 below). 4. Install the mounting plate, with its case-holding posts pointing up, in the location determined. Use two flat head dry-wall screws. Note: To ensure proper operation of the unit's back tamper (when it is separated from the mounting plate), the screws must be anchored to a wall stud or other solid wood material. If the mounting plate will not be used, make note of the location of the tamper switch hold-down as shown in Fig. 1 for the proper placing of the hold-down tab in Fig. 2. 5. If surface wiring is to be used, remove the knockout slot in the case back (located across from loop 3 terminal block). Surface wiring should enter through this knocked out space provided. Do not connect the wiring to the terminal block(s) yet. 6. 7. 8. 9. Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto the mounting plate's holding posts. The locking tab will click as the case back locks in place. To disengage the unit from an installed mounting plate, insert a small screwdriver into the mounting plate release hole, push down to retract the locking tab, and push upward on the unit to disengage from posts. If not using the mounting plate, it is necessary to remove the PC board from the case back. Slide a small flat bladed screwdriver between the case back and PC board near the board hold-down clip and carefully pry the board out. In the area that was previously marked for the location of the mounting plate, (step 4), install the hold-down tab with a 5/8” flat head dry-wall screw. The tab must be aligned with the corresponding slot in the case back as shown in Figure 2. The tab as well as the case back must be anchored to a wall stud or other solid wood material. To reinstall the PC board into the case back, position the board onto the two retaining studs on one side of the case back and snap the board into place. The hold-down tab must mate with the corresponding cutout in the case back after case back is installed. Reverse the procedure of the first three steps to complete reassembly of the unit. 10. Set the DIP switch (after the control panel has enrolled the transmitter's input IDs) for the desired primary loop characteristics, as described in the table below. PRIMARY LOOP OPTIONS TABLE DIP SWITCH POSITION SWITCH SETTING ON OFF Notes: REPEATING TRANSMISSION (every 4 sec.) UPON PRIMARY LOOP FAULT Use for high priority alarm, such as fire. SWITCH MUST ALWAYS BE IN THE SWITCH MUST ALWAYS BE IN THE SWITCH MUST ALWAYS BE IN THE ON SINGLE TRANSMISSION PER PRIMARY LOOP CHANGE-OFSTATE POSITION ON POSITION OFF POSITION a. In order for the control panel to enroll the transmitter, the DIP switches must be set to OFF – ON – ON – OFF (see Figure 3). b. The Auxiliary loops are not affected by the DIP switch settings. 2. Replace battery only with: Duracell DL123A, Panasonic CR123A, Ademco 466 or Varta CR123A. Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212°F (100°C), or incinerate. Dispose of used batteries promptly. Keep away from children. 3. To replace the cover, engage the hooks along the top edge and snap shut. SPECIFICATIONS Dimensions: 1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm) Battery: 3V Lithium (see BATTERY INSTALLATION/REPLACEMENT). UL Listings: Commercial Fire…….UL864 Household Fire………UL985 This is a CLASS B DEVICE Rev. Household Burg……..UL1023 Commercial Burg……UL365, UL609, UL1076, UL1610 TESTING Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. For testing procedures refer to the User Guide or Installation and Setup Guide for the system control panel. The installer should assume the responsibility of developing and offering a regular maintenance program to the user, as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to insure the system's operation at all times. FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE CONTROL PANEL'S INSTALLATION AND SETUP GUIDE FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED. MOUNTING PLATE HOLE TAMPER SWITCH HOLD DOWN If using one of the panel revisions shown in the following table, and programming the 5817CB as an Entry/Exit zone, you must enroll the tamper loop (loop 4) as a separate zone, programmed for 24hour response (e.g., Zone type 5 Trouble-by-day/Alarm-by-night). Model # FA1600C Vista-32FB Vista-128FB Vista-128B Note: HOLD-DOWN TAB UL REQUIREMENT 1. 2. Observe correct polarity and insert the battery provided into the battery holder (see Figure 3). Take care not to bend the antenna. EPROM P/N (WAVIS150FA-18) (WAVIS32FB-13) (WAVIS128FB-14) (WAVIS128B-13) For UL Commercial Burglary installations, this transmitter must be used in conjunction with the 5881ENHC RF Receiver. WIRING CONNECTIONS Connect the loop wiring to the unit's terminals before installing the battery (see Figure 3). Notes: a. Primary loop 1 is a supervised loop and must have an end-of-line (EOL) resistor (470K ohms, supplied) placed across the last sensor. Additionally, for Primary loop 1, a contact device may not be installed more than 20 feet from the transmitter. b. If loop 2 is not going to be used, the magnet is not necessary. c. If loop 3 is not going to be used, no connection is needed across its terminals. For UL household burglary and fire installations, the loop 3 contact device (if used) may not be more than 3 feet from the transmitter. CONCEALED WIRING ENTRY HOLE TAMPER SWITCH HOLD-DOWN TAB CASE HOLDING POSTS CASE BACK INSTALL IN LINE WITH CUT-OUT IN CASE BACK MOUNTING PLATE HOLE CONCEALED WIRING ENTRY HOLE LOCKING TAB MOUNTING HOLES (2) 5817CB-001-V1 5817CB-001-V0 Figure 1. Mounting Plate NOTE: For UL commercial and household fire installations, only one initiating device may be connected to this transmitter. For UL commercial burglary installations, multiple initiating devices may be used as long as the devices all serve the same function, such as door/window contacts, motion or glassbreak detectors. All initiating devices must be located within the same room. Figure 2. Case Back COVER HOLDING SLOTS (2) ANTENNA THE DIP SWITCHES MUST BE SET AS SHOWN DURING ENROLLMENT BY THE CONTROL ALIGN MAGNET WITH MARKS ON CASE (2 PLACES) WHITE AREA INDICATES SWITCH HANDLE ON ON OFF DIP SWITCH FOR PRIMARY LOOP OPTIONS (SEE SETTINGS TABLE) SHOWN SET FOR: 1. SINGLE TRANSMISSION NOTE: SW2 MUST BE ON SW3 MUST BE ON SW4 MUST BE OFF DIP SWITCH LOOP 2 REED SWITCH (AUX) BATTERY COVER TAMPER SWITCH – 1/2" MAX. MAGNET (OBTAIN SEPARATELY) LOOP 3 TERMINALS (AUX) SLOT FOR CONCEALED WIRING ACCESS N.C. CONTACT DEVICE COVER PRY-OFF POINT N.O. CONTACT DEVICE PRIMARY LOOP 1 TERMINALS MOUNTING PLATE RELEASE EOLR 470K ohms 5817CB-002-V1 BATTERY INSTALLATION/REPLACEMENT Figure 3. 5817CB Transmitter, Top Cover Removed 1. Remove the transmitter's cover as described in Mounting Step 1. -2- -3-
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:c2cf19b2-7134-4d50-93c1-3914d9a95ca1 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2007:10:30 16:28:49-04:00 Create Date : 2007:10:30 12:48:49Z Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2007:10:30 16:28:49-04:00 Document ID : uuid:654bde6e-7761-49d0-aa09-90a7f77370b0 Format : application/pdf Title : Microsoft Word - K5623V2_RevA_ii.doc Creator : E651080 Author : E651080EXIF Metadata provided by EXIF.tools