Ademco 8DL6HEAT Rate-Of-Rise Heat Detector User Manual

Honeywell International Inc. Rate-Of-Rise Heat Detector Users Manual

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

Contents

Users Manual

  SiXHEAT Wireless Rate-of-Rise Heat Detector / Détecteur de température thermovélocimétrique General Information The Honeywell SiXHEAT Rate-of-Rise Heat Detector is a wireless device used with controllers that support Honeywell’s SiX™ series devices.   The SiXHEAT combines a rate-of-rise sensor and a fixed temperature sensor in one device.  The rate-of-rise sensor detects a rapid rise in temperature and signals an alarm if the rise is 15F (8C) or more per minute.  Fires typically cause a rapid rise in temperature in the surrounding area.  The fixed temperature sensor will signal an alarm when the ambient temperature rises above 135F (57C). NOTES: • It is not recommended to install at a site where the ambient temperature exceeds 100F (38C). UL: Unit is for dry, indoor use only. • If the fixed temperature sensor activates, the detector must be replaced. • When the battery voltage drops below a threshold, a low battery signal is sent to the controller.  • The SiXHEAT includes a tamper switch.  If removed from it’s mounting base, a trouble signal is sent to the control panel. • Detectors should never be relocated without the advice or assistance of the alarm service company. • Replace the battery when the system reports a low battery condition. IMPORTANT! The SiXHEAT will be permanently damaged if stored, shipped, or installed in environments where the temperature exceeds 100F (38C).  If the metal disc is detached, the detector has exceeded 135F (57C) and must be replaced. Heat detectors should be used for property protection.  Reliance should not be placed solely on heat detectors for life safety.  When life safety is involved, smoke detectors MUST also be used. Detectors MUST NOT be painted. Information Générale Le détecteur de chaleur thermovélocimétrique SiXHEAT de Honeywell est un dispositif sans fil utilisé avec les systèmes qui supportent des dispositifs de la série SiXMC séries. Le SiXHEAT associe un capteur thermovélocimétrique et un capteur thermostatique dans la même unité.  Le capteur thermovélocimétrique détecte une élévation rapide de la température et signale une alarme si l’élévation est de 8C (15F) ou plus par minute.  Les feux causent habituellement une élévation rapide de la température autour d’eux.  Le capteur thermostatique signale une alarme quand la température ambiante s’élève au-dessus de 57C (135F).  NOTES: • Il n’est pas recommandé d’installer un détecteur de chaleur à un endroit où la température ambiante excède 38°C (100°F). • UL : L’unité doit être utilisée seulement à l’intérieur au sec. • Si le capteur thermostatique s’active, le détecteur doit être remplacé. • Lorsque la tension de la pile baisse sous un seuil, un signal de pile faible est transmis au panneau de commande.  • Le SiXHEAT est doté d’un interrupteur antisabotage.  Si le détecteur est séparé de sa plaque de montage, un signal de défectuosité est transmis au panneau de commande. • Les détecteurs ne devraient jamais être changés d’emplacement sans avoir préalablement obtenu l’avis ou l’assistance d’un représentant d’une entreprise de sécurité. • Quand le système signale une condition de pile faible, remplacez la pile. IMPORTANT : Le SiXHEAT sera endommagé de façon permanente s’il est entreposé, expédié ou installé à des endroits où la température est supérieure à 38°C (100°F).  Si le disque de métal est détaché,  le détecteur a dépassé 57°C (135°F) et doit être remplacé.  Des détecteurs de chaleur devraient être utilisés pour la protection des biens.  Pour la protection de la vie, la confiance ne devrait pas reposer uniquement sur les détecteurs de chaleur.  Quand la protection de la vie est en cause, des détecteurs de fumée DOIVENT aussi être utilisés. Les détecteurs NE DOIVENT PAS être peints.
 2 Enrolling / Enrôlement  For Lyric Controller 1. Set the Lyric Controller in Programming Mode and select SiX Programming: Security > Tools > [installer code] > Program > (scroll down) > SiX Programming  Follow the controller’s instructions. 2. Pull the battery tab to activate the SiXHEAT and begin the enrollment process. 3. The LED flashes (up to about 20 seconds*) during enrollment. • The device sends its unique MAC ID (Serial Number) and Services type to the controller.   • The controller registers the device and displays the sensor data on screen.  *NOTE:  Enrollment time varies depending on the  signal strength between the device and the  controller. When done, the LED is ON for 3  seconds and the control beeps to confirm  enrollment. 4. Select the device and press EDIT.  Assign the Zone Descriptor and set the Device Type (SMOKE). Verify the Service and Response Type and set the other options as desired. 5. To complete enrollment, select SAVE. The device can also be manually enrolled by entering the MAC ID (serial number) at the prompt. See the Controller’s Programming Guide for details. Follow instructions in the Controller’s programming guide to program the SiXHEAT zone attributes.  For Lyric Gateway  Use AlarmNet 360™ to enroll and program this sensor. NOTE: Once enrolled in a system, the SiXHEAT  cannot be used with another controller  until  it is removed from the current  controller.  See the Controller’s instructions for details. Pour Lyric Controller 1. Réglez Lyric Controller en mode de programmation et sélectionnez SiX Programming: Sécurité > Outils > [code installateeur] > Program > (défiler vers le bas) > Programmation SiX  Pour commencer l'enrôlement, suivez les instructions du panneau de commande. 2. Retirez la languette qui recouvre la pile pour activer le SiXHEAT et commencer la procédure d'enrôlement. (Ou, si la languette est déjà retirée, utilisez l'aimant.) 3. Durant l'enrôlement, la DEL clignote (jusqu'à 20 secondes*). • Le dispositif transmet au panneau de commande son ID MAC (numéro de série) et l'information pour les services.   • Le panneau de commande enregistre le dispositif et affiche les données du transmetteur sur l'écran.  *NOTE :  La durée de l'enrôlement varie selon la  puissance du signal entre le dispositif et  le panneau de commande. 4. Une fois terminé, la DEL demeure allumée durant 3 secondes et le panneau de commande émet 3 bips pour confirmer l'enrôlement. 5. Sélectionnez la zone et appuyez sur EDIT. Attribuez le descripteur de zone et définissez le type de périphérique (porte ou fenêtre). Vérifiez le type de service et de réponse et définissez les autres options selon vos besoins. 6. Déclenchez de nouveau le dispositif pour mettre fin à l'enrôlement et sélectionnez Enregistrer garder. Le dispositif peut également être enrôlé manuellement.  Pour les détails, reportez-vous au Guide de programmation du panneau de commande. Suivez les instructions du Guide de programmation du panneau de commande pour programmer les SiXHEAT.  Pour Lyric Gateway  Enrôlez et programmez le système au moyen d’AlarmNet 360MC. NOTE : Une fois enrôlé, le SiXHEAT ne peut pas être utilisé  avec un autre système avant d'avoir été supprimé du  panneau actuel. Reportez-vous aux instructions du  panneau.
Download:
Mirror Download [FCC.gov]
Document ID3697120
Application IDIJ4NQFVmFHMuBOCFMPgxPA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.65kB (570642 bits)
Date Submitted2017-12-28 00:00:00
Date Available2018-06-27 00:00:00
Creation Date2017-12-11 16:03:14
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-12-11 16:03:17
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 18 for Word
Document Author: E727032
FCC ID Filing: CFS8DL6HEAT

Navigation menu