Ademco 8DLLMD500 Lyric Smart Peripheral - Motion Detector User Manual Quick Install Manual

Honeywell International Inc. Lyric Smart Peripheral - Motion Detector Quick Install Manual

Quick Install Manual

Download: Ademco 8DLLMD500 Lyric Smart Peripheral - Motion Detector User Manual Quick Install Manual
Mirror Download [FCC.gov]Ademco 8DLLMD500 Lyric Smart Peripheral - Motion Detector User Manual Quick Install Manual
Document ID2728371
Application ID5s9C9FIZIPDFb6I7V9cqkQ==
Document DescriptionQuick Install Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize53.63kB (670314 bits)
Date Submitted2015-08-27 00:00:00
Date Available2016-02-21 00:00:00
Creation Date2015-08-05 12:33:09
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-08-18 16:00:28
Document TitleQuick Install Manual
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: E727032

PLEASE SEE BOTTOM OF PAGE FOR FCC/IC AGENCY STATEMENTS
This wireless passive infrared motion
sensor is intended for use with
Honeywell controls that support SiX™
series devices.
FC: This wireless passive infrared
motion sensor is intended for use
with Honeywell controls that support
SiX™ series devices.
SP: This wireless passive infrared
motion sensor is intended for use
with Honeywell controls that support
SiX™ series devices.
PA: This wireless passive infrared
motion sensor is intended for use
with Honeywell controls that support
SiX™ series devices.
Motion Sensor
Open /
Open / Open
Mounting Locations / Mounting Locations /
Mounting Locations / Mounting Locations
NOTE: After enrolling and before mounting permanently, conduct Go/No Go tests (see controller’s
instructions) to verify adequate signal strength. Adjust the device location and orientation as
necessary.
NOTE: Once enrolled, the sensor
cannot be used with another system
until it is removed from the current
controller. See the controller’s
instructions.
FC: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see
controller’s instructions) to verify adequate signal strength. Adjust the device location and
orientation as necessary.
FC: NOTE: Once enrolled, the sensor
cannot be used with another system
until it is removed from the current
controller. See the controller’s
instructions.
SP: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see
controller’s instructions) to verify adequate signal strength. Adjust the device location and
orientation as necessary.
PA: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see
controller’s instructions) to verify adequate signal strength. Adjust the device location and
orientation as necessary.
SP: NOTE: Once enrolled, the sensor
cannot be used with another system
until it is removed from the current
controller. See the controller’s
instructions.
PA: Once enrolled, the sensor cannot
be used with another system until it
is removed from the current
controller. See the controller’s
instructions.
Enroll / Enroll / Enroll / Enroll
Mounting Options / Mounting Options /
Mounting Options / Mounting Options
Walk Test / Walk Test / Walk Test / Wal
NOTE:
NOTE:
NOTE:
NOTE:
Before using Test Mode, the device must first be enrolled in the controller.
To enter Test Mode, the device must first be enrolled in the controller.
To enter Test Mode, the device must first be enrolled in the controller.
To enter Test Mode, the device must first be enrolled in the controller.
Replace Battery / Replace Battery /
Replace Battery / Replace Battery
NOTE:
NOTE:
NOTE:
NOTE:
Zones / Zones / Zonas / Zonas
18
Lower / Courtes /
Cercana/ Mais baixas
46
Intermediate /
Intermédiaires / Intermedia
/ Intermédias
36
Long / Longues / Largo
Alcance / Longo alcance
To conserve battery life, the sensor is active only when
To conserve battery life, the sensor is only active when
To conserve battery life, the sensor is only active when
To conserve battery life, the sensor is only active when
the system
the system
the system
the system
is armed.
is armed.
is armed.
is armed.
BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F
(100° C) or incinerate. Dispose of used batteries properly. Keep away from children.
FC:BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F
(100° C) or incinerate. Dispose of used batteries promptly. Keep away from children.
SP: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F
(100° C) or incinerate. Dispose of used batteries promptly. Keep away from children.
PA: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F
(100° C) or incinerate. Dispose of used batteries promptly. Keep away from children.
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
Detection Patterns / Detection Patterns /
Detection Patterns / Detection Patterns
Approval Listings:
FCC / IC
SIA-PIR-01
ETL Listed to UL639
cETL Listed to ULC S306-03
RoHS
Specifications:
Range: 40’ x 56’ / 12 m x 17 m
Wall Mounting Height: 7’ – 9’ (2.1 m – 2.7 m); Optimal 7’6” (2.3 m)
Battery: 1 x 3V, Lithium; Panasonic CR123A, Duracell DL 123A,
Duracell DL 123, Honeywell 466
RF Frequency: 2.4GHz
Tamper: Cover and Wall – reported separately to panel.
Operating Temperature: 32° – 122° F / 0° – 50° C (Agency
Compliance 32° – 120° F / 0° – 49° C)
Relative Humidity: 95% max. (Agency Compliance - 93% max.),
non-condensing
Dimensions: 4.13” H x 2.38” W x 1.61” D / 105 mm H x 60.4 mm W
x 41 mm D
Product must be tested at least once each year / Le fonctionnement du produit doit être
vérifié au moins une fois par année / El producto debe ser probado al menos una vez al
año / O produto deve ser testado pelo menos uma vez por ano
 2014 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved
www.honeywell.com/security
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the
equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement
est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit
accepter toute interférence reçue y compris les interférences causant une reception indésirable.
RF Exposure Warning – The antenna(s) used for this device must be installed to provide a separation distance of at
least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter except in accordance with FCC multi-transmitter product procedures.
Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une
distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS
USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Support / Support / Support / Support
https://mywebtech.honeywell.com/
U.S. warranty / U.S. warranty / U.S. garantie / U.S. garantia
www.honeywell.com/security/hsc/resources/wa
MyWebTech
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Warranty
Ê800-15963bŠ
800-15963 11/15 Rev B BETA2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : E727032
Create Date                     : 2015:08:05 12:33:09-07:00
Modify Date                     : 2015:08:18 16:00:28-04:00
Has XFA                         : No
Language                        : EN-US
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:08:18 16:00:28-04:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:d586f450-e362-43ee-9835-867337d7d3e5
Instance ID                     : uuid:5e1c2027-518c-418d-9ad6-f4c0ae378057
Subject                         : 2
Format                          : application/pdf
Creator                         : E727032
Producer                        : Adobe PDF Library 11.0
Source Modified                 : D:20150805193251
Company                         : Honeywell
Page Layout                     : OneColumn
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CFS8DLLMD500

Navigation menu