Ademco 8DLLRS500 Lyric Smart Peripheral - Siren User Manual Quick Install Guide
Honeywell International Inc. Lyric Smart Peripheral - Siren Quick Install Guide
Ademco >
Contents
- 1. Manual Information
- 2. Installation Manual
- 3. Quick Install Guide
Quick Install Guide
PLEASE GO TO THE LAST PAGE FOR FCC/IC AGENCY STATEMENTS LEDS and SOUNDERS / LEDS and SOUNDERS / LEDS and SOUNDERS / LEDS and SOUNDERS This wireless siren/strobe is intended for use with Honeywell controls that support SiX™ series devices. FC: This wireless siren/strobe is intended for use with Honeywell controls that support SiX™ series devices. SP This wireless siren/strobe is intended for use with Honeywell controls that support SiX™ series devices. PA: This wireless siren/strobe is intended for use with Honeywell controls that support SiX™ series devices. R/W SIREN G/W Sounder OPEN / OPEN / OPEN Status Power Up – Enrollment / Power Up – Enrollment / Power Up – Enrollment / Power Up – Enrollment Power Up – Device Power Up – Device Power Up – Device Power Up – Device NOTE: Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the controller’s instructions, System System System System FC: NOTE: Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the controller’s instructions, SP: NOTE: Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the controller’s instructions, 3 sec PA: NOTE: Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the controller’s instructions. 3 sec Enroll / Enroll / Enroll / Enroll enrolled / enrolled / enrolled/ enrolled is Disarmed / is Disarmed / is Disarmed / is Disarmed System is Armed / System is Armed / System is Armed / System is Armed Smoke or CO Alarm / Smoke or CO Alarm / Smoke or CO Alarm / Smoke or CO Alarm Burglary Alarm / Burglary Alarm / Burglary Alarm / Burglary Alarm Low Battery / Low Battery / Low Battery / Low Battery Tamper Activated / Tamper Activated / Tamper Activated / Tamper Activated Starts chirping after 7 days, continues until the batteries are replaced or die. / Starts chirping after 7 days, continues until the batteries are replaced or die / Starts chirping after 7 days, continues until the batteries are replaced or die / Starts chirping after 7 days, continues until the batteries are replaced or die NOTE: After enrolling and before mounting permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. FC: NOTE: After enrolling and before mounting permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. SP: NOTE: After enrolling and before mounting permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. PA: NOTE: After enrolling and before mounting permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. Mount / Mount / Mount / Mount Consult the Controller’s instructions to program the Siren Services: Siren Chime mode sound level; Tamper, and Temperature Sensing. FC: Consult the Controller’s instructions to program the Siren Services: Siren Chime mode sound level; Tamper, and Temperature Sensing. SP: Consult the Controller’s instructions to program the Siren Services: Siren Chime mode sound level; Tamper, and Temperature Sensing. PA: Consult the Controller’s instructions to program the Siren Services: Siren Chime mode sound level; Tamper, and Temperature Sensing. 35dB 55dB 85dB Factory default / Valeurs par défaut du fabricant / Defecto de fábrica / Padrão de fábrica Life Safety / Life Safety / Life Safety / Life Safety Program / Program / Program Approval Listings: Specifications: FCC / IC ETL Listed to UL985 / UL1023 cETL Listed to ULC-S545 & ULC/ORD-C1023 RoHS Range: 0’- 25’/ 0 – 7.6m; Selectable RF Frequency: 2.4GHz Batteries: 4 x 1.5V, AA Lithium; Honeywell 462 Tamper: Cover and Wall Operating Temperature: 32° – 122° F / 0° – 50° C (Agency Compliance 32° – 120° F / 0° – 49° C) Relative Humidity: 95% max. (Agency Compliance - 93% max.), non-condensing Dimensions: 3.78” Diameter x 1.14” Thick / 96 mm Diameter x 29mm Thick Product must be tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année / El producto debe ser probado al menos una vez al año / O produto deve ser testado pelo menos uma vez por ano 2014 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved www.honeywell.com/security BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries properly. Keep away from children. FC: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. SP: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. PA: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. Replace Battery / Replace Battery / Replace Battery Support / Support / Support / Support https://mywebtech.honeywell.com/ U.S. warranty / U.S. warranty / U.S. garantie / U.S. garantia www.honeywell.com/security/hsc/resources/wa MyWebTech Warranty FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception indésirable. RF Exposure Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Ê800-15964kŠ 800-15964 11/15 Rev B BETA2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Has XFA : No Language : EN-US XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Modify Date : 2015:08:21 15:21:40-04:00 Create Date : 2015:08:05 12:48:10-07:00 Metadata Date : 2015:08:21 15:21:40-04:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:728fa3e2-9880-4381-a937-603d0cb24524 Instance ID : uuid:dcb74f7d-a653-4a54-a48e-87549a991bfb Subject : 2 Format : application/pdf Creator : E727032 Producer : Adobe PDF Library 11.0 Source Modified : D:20150805194759 Company : Honeywell Page Layout : OneColumn Page Count : 2 Author : E727032EXIF Metadata provided by EXIF.tools