Ademco 8DLSL5011 Multi-Band Wireless Modem Module Cartridge User Manual Rev 7B

Honeywell International Inc. Multi-Band Wireless Modem Module Cartridge Users Manual Rev 7B

Users Manual Rev 7B

   Lyric-CDMA Installation Instructions   Lyric-CDMA  Communication Module Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/MyWebTech  General Information The Lyric-CDMA Communication Module allows the Lyric Smart Controller to communicate with the Central Station via the cellular radio network. NOTE: Before installing the communication module, remove power from the control or use the “Install Cell” mode described in the Replacing the Module section below.  Installing the Lyric-CDMA Module 1. Install the provided FCC/IC label (P/N 800-19688) on the control’s case back.  2. Remove bezel from right-hand side of control to expose the radio module slot To remove bezel, push upward.  3. Insert the module into the slot. Push firmly to mate the edge connector.  4. Replace the bezel.  5. Use AlarmNet Direct to enable the Lyric-CDMA module, configure alarm reporting and module supervision, and register the module.  Typical FCC/IC Label Location     Removing the Bezel    Installing the Lyric-CDMA Module  Replacing the Module In the event the module needs to be replaced, the Control must first be put in module replacement (“Install Cell”) mode to avoid causing a tamper alarm.  1. Select  the Install Cell button.    (Security – More – Tools – enter code – Test – Install Cell)  This mode deactivates tamper protection so the side bezel can be removed without causing an alarm.  2. Remove the side bezel. See diagram above.  3. Remove the screw that secures the module to the control.  4. Remove the communication module from its connection slot. 5. Insert the new module into the slot. Push firmly to mate the edge connector. Replace the securing screw.  6.  Replace the bezel.  7.  Use AlarmNet Direct to enable the Lyric-CDMA module, configure alarm reporting and module supervision, and register the module.   HONEYWELL PRELIMINARYPLEASE GO TO BOTTOM OF THE NEXT PAGE FOR FCC / IC AGENCY STATEMENTS.
Ê800-191807Š 800-19180  12/14  Rev. A 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2014 Honeywell International Inc. www.honeywell.com/security Electrical Specifications Voltage Input .. 5V (provided by the control panel) Current Idle ................ 15 mA, standby Average ........ 300mA, average transmit Peak 1.6A peak transmit, 25% duty cycle FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC CLASS B STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •If using an indoor antenna, have a quality outdoor antenna installed.•Reorient the receiving antenna until interference is reduced or eliminated.•Move the radio or television receiver away from the receiver/control.•Move the antenna leads away from any wire runs to the receiver/control.•Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.•Consult the dealer or an experienced radio/TV technician for help.INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation.  Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. RF Exposure Warning The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 7.8 in (20 cm) from all persons and must not be co-located or operated in conjunction with any other transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à  une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. IMPORTANT NOTE ABOUT EXTERNAL ANTENNAS If an external cellular radio antenna is used, the antenna may be installed or replaced ONLY by a professional installer. TO THE INSTALLER For the Lyric-CDMA, the external antenna must not exceed a maximum directional gain (including cable loss) of 9.3 dBi at 850 MHz and 8.2 dBi at 1900 MHz. SUPPORT & WARRANTY For the latest documentation and online support information, please go to: www.security.honeywell.com/hsc/resources/MyWebTech For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa. HONEYWELL PRELIMINARY

Navigation menu