Ademco RTU-L12 Access Control Terminal User Manual RTUL19

Honeywell International Inc Access Control Terminal RTUL19

manual

Download: Ademco RTU-L12 Access Control Terminal User Manual RTUL19
Mirror Download [FCC.gov]Ademco RTU-L12 Access Control Terminal User Manual RTUL19
Document ID596013
Application IDiB17ISAykiXpoAJlOnYDbQ==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.59kB (769859 bits)
Date Submitted2005-10-26 00:00:00
Date Available2005-10-26 00:00:00
Creation Date2005-10-20 15:47:54
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2005-10-20 15:48:19
Document TitleRTUL19
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: gmariotti

TKL12 (RTUL12)
Installation Manual
Tema1.0_L12_IM_1.1_EN
Pagina 1 di 1
CONTENTS
FCC NOTICE .............................................................................................. 3
Canadian Compliance Statement ........................................................ 3
1.1 Wall Set Up for the Cable Trays ......................................................... 4
1.2 Electrical Connections ........................................................................ 5
1.3 LONWORKS Data Cables ................................................................ 7
1.4 Mounting the Wall Bracket.................................................................. 8
1.5 LON, power and door wiring ............................................................. 10
1.5.1
LON Cable............................................................................ 10
1.5.2
Power Supply Cable +12VDC .............................................. 11
1.5.3
Input Cable 1 – Door Contact............................................... 12
1.5.4
Input Cable 2 – Push Button ................................................ 13
1.5.5
Output 1 – Door lock ............................................................ 14
1.5.6
Output 2 – Door status light.................................................. 15
1.6 Mounting the Device on the Wall Bracket......................................... 16
1.7 Identification Using the Service Pin .................................................. 17
1.8 Identification Using the Neuron ID .................................................... 18
2.1 TemaKey TKL12 (RTU-L12 code 1500159XX) .................................. 19
2.1.1
Supplied Parts ...................................................................... 20
2.1.2
Optional Parts....................................................................... 20
2.2 Recycling .......................................................................................... 21
Page 2
FCC NOTICE
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, these is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by tuning the equipment off and on, the
user is encouraged to try to correct the interference by one or more the
following measures:
-----
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: any modification or change not expressely approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
Canadian Compliance Statement
This Class B Digital apparatus meets all the requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe B respecte les exigences du Reglement
sur le material broilleur du Canada.
Page 3
P R E P A R A T IO N S
1.1 Wall Set Up for the Cable Trays
The cables must:
1) Protrude from the wall.
120 cm
2) Come out at 120cm from ground (see Figure 1) (advised).
cable tray
cables
Floor
Figure 1: Wall Set Up for the Cable Trays
Version: 1.1 EN
Page 4
1.2 Electrical Connections
The RTU is powered at low voltage (12VDC 160mA), preferably using a
power supply module with battery backup (RTU-Qxx), or using an ordinary
power supply having the same characteristics. The power cables must be
dimensioned as indicated in the table below. The maximum allowable voltage
drop on the power cable is 1V.
• Cable length(m) = 1V / (I[A] load x 2 x (res [Ohm/km] /1000))
AWG
Ext ensi on [ m] based on
Cabl e Type
mm2
ohm/ Km 160 [ mA] 320 [ mA]
12
3. 3
5. 7
548
274
14
8. 8
355
178
16
1. 3
14
223
112
18
0. 9
21
149
74
20
0. 6
34
92
46
22
0. 35
52
60
30
24
0. 2
85
37
18
l oad
The device is equipped with 2 non-removable cables of 3m length:
• Two-pole, twisted, unpolarized cable dedicated to the LON line
connection
- LON a
0,325 mm2 white
- LON b
0,325 mm2 orange
• Six-pole cable, providing the following signals:
- +12VDC
0,2 mm2 red
- GND
0,2 mm2 black
- INPUT 1 +
0,2 mm2 brown
- INPUT 2 +
0,2 mm2 orange
- OUT OC1
0,2 mm2 yellow
- OUT OC2
0,2 mm2 green
The signals must be connected using a shunt box with IP protection level
in conformance with the type of environment in which it is to be used:
- IP55 for moist environments
- Recessed box or IP31 at least for inside installations
The shunt box must be positioned within the perimeter controlled by the
access control system.
The repeater relays must be inserted inside the box for electrical locking
commands and the signal light.
Page 5
2-pole LON
cable
4 mm diameter
3 metri
7,20 cm
8,00 cm
15,60 cm
6,10 cm
6 pole
cable
5,3mm
diameter
Figure 2: Position and dimensions of the non-removable cables
3 meters
4,20 cm
RTUL12
Cable OUT 1
Cable OUT 2
Cable IN 2
Cable IN 1
Cable LON
Cable +12VDC
Shunt Box
Figure 3: Shunt Box
Page 6
1.3 LONWORKS Data Cables
• The LONWORKS1 data cables must be double twisted-pair cables
• In a free topology configuration, the overall length of the sections must not
exceed 500m
• In a bus configuration, the overall length of the sections must not exceed
2700m
• In the free topology configuration, the 50ohm terminator must be enabled
by inserting the appropriate jumper into the FTT10A plug-in on the CTUPLG06 board inside the TemaServer
• In a bus configuration, two terminators must be inserted at the two ends of
the bus (resistance of 100ohm 1% ½W)
• The LONWORKS1 data cables must be dimensioned according to the
indications in Table 1
Cable Type
Extension [m] based on cable capacitance
AWG
mm
Ohm/Km 50nF/Km 100nF/K 200nF/K 500nF/K 1uF/Km
12
3.3
5.7
2676
1892
1338
846
598
14
8.8
2153
1523
1077
681
482
16
1.3
14
1707
1207
854
540
382
18
0.9
21
1394
986
697
441
312
20
0.6
34
1096
775
548
346
245
22
0.35
52
886
626
443
280
198
24
0.2
85
693
490
346
219
155
Table 1: Length/Capacitance of LONWORKS1 Cables
• The FTT10A Echelon v1.2 User’s Guide suggests using the cables as
indicated in Table 2.
Make and Model
AW
Belden 85102
Belden 8471
Level IV (twisted pair,
solid, unshielded)
JY (St) 2x2x0,8 (4
solid wires, spiraltwisted, shielded)
TIA Cat5
16
16
22
Bus
Connection
Max Length
total [m]
2700
2700
1400
Free Topology
Connection Nodeto-Node Max
Length [m]
500
400
400
20
900
320
500
900
250
450
Table 2: Suggested LONWORKS Cables
Free Topology Connection
Max Length total
[m]
500
500
500
LONWORKS® is a trademark of the Echelon Corporation
Page 7
1.4 Mounting the Wall Bracket
Mount the bracket onto the wall as follows:
1. Placing the bracket against the wall and mark the proper positions of the
three holes, make the holes for the three bolts that will go into the wall to
hold the bracket and the bolt for the tamper switch (the bolts are included
in the installation kit)
2. Make sure that the cable tray matches with the hole for the passage of the
cables
3. Fix the plate and adjust the tamper screw.
Hole for Cables
Holes for wall
mounting
Reference for tamper
adjusting screw
Mark in the center (hole
diameter 4mm)
Figure 4: Wall Bracket: Front and Side View
Page 8
Adjust the
screw so that
is in line with
the bracket
surface
Figura 5: Tamper adjusting screw
Page 9
1.5 LON, power and door wiring
1.5.1 LON Cable
3 meters
6,10 cm
LON A
LON B
Note: connection
not polarized
Figure 6: LON (1) Cable Connection
Page 10
1.5.2 Power Supply Cable +12VDC
3 meters
6,10 cm
12VDC (red)
GND (black)
Figure 7: Power Supply Connection
Page 11
1.5.3 Input Cable 1 – Door Contact
Supervised input1 is for the door status control; resistors must be installed
at the door contacts.
Yellow
NC CONTACT
White
magnetic door contact
IN1 (brown)
GND (black)
Figure 8: Supervised Input 1 connection – Door Contact
Yellow resistor: 1210 Ohm 1%
White resistor: 392 Ohm 1%
Close contact resistance: 296 Ohm
Open contact resistance: 1210 Ohm
Max wires resistance: 25 Ohm
Page 12
1.5.4 Input Cable 2 – Push Button
Supervised input 2 is for the push button status; resistors must be installed
at the door push button contacts.
Yellow
NO CONTACT
White
button contact
IN2 (orange)
GND
Figure 9: Supervised Input 2 connection– Push button
Yellow resistor: 1210 Ohm 1%
White resistor: 392 Ohm 1%
Push button close resistance: 296 Ohm
Push button open resistance: 1210 Ohm (normality)
Max wires resistance: 25 Ohm
Note: in case the push button is unused the INPUT has to be
terminated with the Yellow resistor.
Page 13
1.5.5 Output 1 – Door lock
The open collector output 1 (I max = 100mA) is used for door lock.
An external DC relay must be installed in accordance with the following
limits:
• Max relay voltage = 28VDC
• Max relay current = 100mA
• Max Vce(sat at 100mA) = 1.2V
It is mandatory to use the 1N4004 (or equivalent) provided diode in
parallel to the coil of the relay.
VEXT_relè
Relay coil
diode 1N4004
OUT1
GND
NO
NC
Vdc / ac
Transient
suppressor
Electrolock coil
Vdc / ac
Inductive load with alternating current: not allowed
Figure 10: Output 1connection – Door Lock
Page 14
1.5.6 Output 2 – Door status light
The open collector output 2 (I max = 100mA) is used for signaling the
status of the door (gateway occupied / free).
An external DC relay must be installed in accordance with the following
limits:
• Max relay voltage = 28VDC
• Max relay current = 100mA
• Max Vce(sat at 100mA) = 1.2V
It is mandatory to use the 1N4004 (or equivalent) provided diode in
parallel to the coil of the relay.
VEXT_relè
Relay coil
diode 1N4004
OUT2
GND
NO
NC
Vdc / ac
Transient
suppressor
Electrolock coil
Vdc / ac
Inductive load with alternating current: not allowed
Figure 11: Output 2 connection- door status light
Page 15
1.6 Mounting the Device on the Wall Bracket
Figure 12: Mounting
1) The RTUL12 is positioned atop the wall bracket protrusion
2) The back part is aligned with the wall by rotating
3) The RTUL12 is mounted onto the bracket using screws
Page 16
ACTIVATION
1.7 Identification Using the Service Pin
To identify the node, you can call the service pin using the relay-reed found
inside the device (see Figure 13). Use the following steps for this procedure:
1. Place a small magnet as indicated in Figure 13 to call the service pin. The
signal is linked to the yellow service LED (at the center), which will blink
throughout the operation.
2. The TemaServer will send a wink command in response to the service pin,
which lights the yellow LED and the buzzer three times. This allows you to
verify that communications are operational to and from the TemaServer.
3. Check to see that the service LED is off at the end of the operation.
Position of
magnet
The LED
goes
yellow
Figure 13: Calling the Service Pin Using a Magnet
Page 17
1.8 Identification Using the Neuron ID
The label with the neuron ID that comes with the kit must be applied by the
installer on the appropriate identification sheet. You also must indicate the
location of the terminal in the appropriate box (see example in Table 3).
Description of Location
Entrance to Offices, First Floor, Stairway E
Description of TemaServer
Panel2, Entrance, First Floor, Stairway E
RTUL19
Table 3: Example of Compiled Identification Sheet
Page 18
2 TECHNICAL DATA
2.1 TemaKey TKL12
(RTU-L12 code 1500159XX)
Parameter
Value
Power Supply
Weight
Dimensions
Degree of Protection
Operational
Temperature
Storage Temperature
Relative Humidity of
Storage
LED
Buzzer
Inputs
12VDC±15%
160mA
(2W)
0.3 kg
156 x 40 x 27 mm (see Figure 14)
IP55
-20 to 60 °C
Output OC 1
Output OC 2
Antenna proxy
LONWORKS®2
Connection
-20 to 70 °C
0 to 95 % without condensation
1 LED tricolor Red / Green / Yellow
2 supervised inputs with 4 statuses:
normal, alarm, cut, short
Electrical Locking Device Command
Vmax = 28VDC
I max = 100mA
Vce(sat) max = 1,2V
Lamp Command
Vmax = 28VDC
I max = 100mA
Vce(sat) max = 1,2V
13,56MHz for 14443A / B cards
Reading range: depending on technology of
card. Typical 4 cm
"Free Topology" type connected with
unshielded double twisted pair cable
FT3150 Smart Transceiver, 78Kbps
Directive EMC 89/336/EEC, 92/31/EEC,
Low Voltage Directive 72/23/EEC, 93/68/EEC:
EN60950 / EN55022-B / ETSI EN300-330 / EN55024
Conformance to Norms
FCC
FCC ID: HS9-RTU-L12
T h is d e v ice c o m p lie s w it h P a r t 15 o f th e F C C R u les .
O p e ra tio n is su b jec t t o th e f o llo w in g t w o co n d it io n s:
( 1) t h is d e v ic e m a y n o t ca u s e h a rm f u l in t er fe r e n c e , an d
( 2) t h is d e v ic e m u s t a c ce p t a n y in t er fe re n ce r ec e iv e d ,
in c lu d in g in t e rf er en c e th at m a y ca u s e u n d es ir ed o p era tio n .
LONWORKS® is a trademark of the Echelon Corporation
Page 19
2.1.1 Supplied Parts
KIT of resistances for
input balancing
Fisher bolts for wall
mounting
Fisher bolt for tamper
1N4004 Diode
2 White resistances
2 Yellow resistances
2 (S4 type) + screws
1 (S4 type) + screws
2.1.2 Optional Parts
TORX TX10 Screwdriver
Code 1500108AA
Page 20
2.2 Recycling
In application of directive 2002/96/EC regarding electrical and electronic waste devices, from 13 August 2005,
Honeywell engages, when requested by the customer, to the collection, treatment, recovery, and proper disposal of all
devices produced.
All users within the European Union are hereby informed of the requirement for the proper elimination of the product as
regulated by laws, rules, and local procedures.
Page 21
Figure 14: Temakey TKL12
Page 22

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2005:10:20 15:48:19+03:00
Create Date                     : 2005:10:20 15:47:54+02:00
Page Count                      : 22
Creation Date                   : 2005:10:20 13:47:54Z
Mod Date                        : 2005:10:20 13:47:54Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : gmariotti
Metadata Date                   : 2005:10:20 13:47:54Z
Creator                         : gmariotti
Title                           : RTUL19
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HS9-RTU-L12

Navigation menu