Ademco TH8320ZW01 TH8320ZW1000 Touchscreen Thermostat User Manual 69 2485EFS 03 TH8320ZW1000
Honeywell International Inc TH8320ZW1000 Touchscreen Thermostat 69 2485EFS 03 TH8320ZW1000
Ademco >
Users Manual
Operating Manual TH8320ZW1000 Touchscreen Thermostat 69-2485EFS-03 BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent damage to the thermostat, always press keys with your fingertip. ENGLISH This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate M29343 Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Read and save these instructions. ® U.S. Registered Trademark. US Patent No. 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576, and other patents pending. Copyright © 2011 Honeywell International Inc. All rights reserved. TH8320ZW1000 Table of contents About your new thermostat Appendices Thermostat features ............................... 2 Programming at a glance ....................... 3 Quick reference to controls .................... 4 Quick reference to status display .......... 5 In case of difficulty ............................... 18 Regulatory information ......................... 20 Limited warranty................................... 21 Clock setting .......................................... 6 Fan setting.............................................. 7 System setting ....................................... 8 This thermostat is ready to go! Your new thermostat is preprogrammed and ready to go. See page 3 to check settings. Programming & Operation Screen lock ............................................ 9 Screen cleaning.................................... 10 Battery replacement ............................. 11 Advanced functions ............................. 12 CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50˚F (10˚C). 69-2485EFS—03 ENGLISH Settings Operating Manual About your new thermostat Congratulations! You’ve just purchased the world’s most advanced, easy-to-use themostat. It has been designed to give you many years of reliable service and touchscreen climate control. ENGLISH Features • One-touchtempcontroloverridesprogramscheduleatanytime. • Precisecomfortcontrolkeepstemperaturewithin1°Fofthelevelyouset. • Change/checkremindersletyouknowwhentoserviceorreplacefiltersandother critical components. • Largetouchscreendisplaywithbacklightiseasytoread—eveninthedark. • Z-WavewirelesscontrolletsyouconnectthethermostattoaZ-Wavenetwork. 69-2485EFS—03 TH8320ZW1000 About This thermostat your new thermostat is ready to go! Your new thermostat is pre-programmed and ready to go. Just set the time and day. Then check the settings below and change if needed: 1. Set clock .......................................................................................................See page 6 3. Select system setting: Preset to Heat ......................................................See page 8 69-2485EFS—03 ENGLISH 2. Select fan setting: Preset to Auto..............................................................See page 7 Operating Manual Quick reference to controls Press day(s) to set program schedule Press to select fan operation (see page 7) MON TUE WED THU FRI SAT SUN ENGLISH Press to select system type (see page 8) Press to adjust temperature settings Press for more options (select models only) Press to set schedule SUN M32520A Press to override program schedule 69-2485EFS—03 Press to set clock (see page 6) Press to lock keypad for 30 seconds to clean screen (see page 10) TH8320ZW1000 Quick reference to status display Current day of week Current inside temperature Inside Set To 75 FAN AUTO System setting 70 Following Schedule SUN SYSTEM 8:10 HEAT Program schedule on (does not display when off) AM Recovery Current time SCHED HOLD CLOCK Adaptive Intelligent Recovery in effect SCREEN M32521 Other display messages: • Cool On: Cooling system is activated • Heat On: Heating system is activated • Aux Heat On: Auxiliary heating system is activated 69-2485EFS—03 ENGLISH Fan setting Temperature setting Operating Manual Clock setting Press CLOCK 6:01 SCHED To set the current time display, press CLOCK, then press s or t to adjust the time. Press and hold s or t to advance the time more quickly. WED AM HOLD CLOCK SCREEN MORE ENGLISH M32527 Adjust time, then press DONE Press DONE to save & exit (or press CANCEL to exit without changing the time). Note: The real-time clock should never require FAN AUTO 70 Inside Set To adjustment since it automatically updates for daylight savings time, and stores all date/time information. 70 Note: To change the current week day display, see page 13. WED 6:02 AM DONE CANCEL M32528 69-2485EFS—03 TH8320ZW1000 Fan setting Press FAN to select fan operation, then press DONE. Inside AUTO 70 SYSTEM HEAT SCHED • Auto: Fan runs only when the heating or cooling system is on. 70 • Circ: Fan runs randomly, about 35% of the time, including any run time with the heating or cooling system. Following Schedule WED 6:01 • On: Fan is always on. Set To AM HOLD CLOCK SCREEN M32529 Press FAN Note: If a fan schedule is programmed, “Auto” will run the fan schedule. You can press FAN to override the fan settings you’ve programmed for different time periods. If you select On or Circ, the setting you select will remain active until you press FAN again to select Auto (see page 19 for more information). 69-2485EFS—03 ENGLISH FAN Operating Manual System setting Press the SYSTEM button to select, then press DONE. Inside ENGLISH FAN AUTO SYSTEM 70 70 6:01 SCHED • Cool: Thermostat controls only the cooling system. Following Schedule WED HEAT • Heat: Thermostat controls only the heating system. Set To • Off: Heating and cooling systems are off. AM HOLD CLOCK SCREEN M32522 Press SYSTEM 69-2485EFS—03 • Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature. • Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat. TH8320ZW1000 About your Screen locknew thermostat To prevent tampering, the screen can be partially or fully locked. WED SCREEN LOCKED FAN AUTO Set To 70 Whenpartiallylocked,thescreendisplays SCREEN LOCKED for several seconds if a locked key is pressed. To unlock the screen, press any unlocked key while SCREEN LOCKED appears on the screen. Following Schedule HEAT 6:00 SCHED PM HOLD CLOCK SCREEN MORE M29357 Whenthescreenisfullylocked,nokeys function. To lock or unlock the screen, see advanced function 0670 on page 17. See advanced function 0670 (page 17) for screen lock options 69-2485EFS—03 ENGLISH SYSTEM 70 Inside Operating Manual About your Screen cleaning new thermostat Press SCREEN Press SCREEN to lock the screen for cleaning. The screen will remain locked for 30 seconds so you can clean the screen without changing any settings. WED 6:00 ENGLISH SCHED PM HOLD CLOCK SCREEN USAGE M32526 Screen lock timer (30 seconds) After 30 seconds, press DONE to resume normal operation, or press SCREEN again if you require more time for cleaning. Note: Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, then use the damp cloth to clean the screen. Use water or household glass cleaner. Avoid abrasive cleansers. M32523 69-2485EFS—03 10 TH8320ZW1000 Battery replacement Remove tab. M32429 11 69-2485EFS—03 ENGLISH The thermostat is shipped from the factory with the coin cell installed. To keep the battery from discharging during shipment and storage, the thermostat is shipped with a plastic tab inserted in the battery holder. This tab must be removed during installation. Simply pull the plastic tab out of the battery tray. Make sure that the battery tray is fully inserted into the thermostat. Operating Manual Advanced functions 2. Press and hold blank center key until the display changes. 1. Press SYSTEM. 6:01 SYSTEM SUN HEAT AM ENGLISH DONE CANCEL M32530 M32525 Function 3. Change settings as required (see pages 13-17). 0120 Setting 20 DONE M32531 4. Press DONE to exit & save changes. 69-2485EFS—03 12 Press s / t to select function Press s / t to change setting TH8320ZW1000 Advanced functions Year setting (first two digits) Function 0120 Options: Press s / t to change the first two digits of the year: 20 = Year 20xx 21 = Year 21xx ENGLISH Year setting (second two digits) 0130 Options: Press s / t to change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) Month setting 0140 Options: Press s / t to change the current month: 1 - 12 (i.e., January - December) Date setting 0150 Options: Press s / t to change the current date: 1 - 31 Program schedule on/off 0160 Options: Press s / t to turn the program schedule on or off: 0 Non-programmable 4 Programmable 13 69-2485EFS—03 Operating Manual Advanced functions Restore Energy Saving Schedule Function 0165 Press s / t to restore the Energy Saving Schedule Options: 0 No 1 Yes ENGLISH Continuous Backlight 0280 Options: Press s / t to set the continuous backlight 0 No 1 Yes Temperature format (°F/°C) 0320 Options: Press s / t to set the temperature display format: 0 Fahrenheit 1 Celsius Daylight savings time on/off 0330 Options: The thermostat is pre-programmed to automatically adjust to daylight savings time. Press s / t to select an option: 0 Off:Noadjustmentfordaylightsavingstime 1 On:Auto-changetodaylightsavingstime(forareasthatdonotusethenew DST calendar) 69-2485EFS—03 14 TH8320ZW1000 Advanced functions Furnace Filter Change Reminder Function 0500 Options: Press s / t to set the filter-change reminder Off 10-day run time (about 1 month) 30-day run time (about 3 months) 60-day run time (about 6 months) 90-day run time (about 9 months) 120-day run time (about 1 year) 180-day run time (about 1.5 years) 270-day run time (about 2 years) 365-day run time (about 3 years) 30 calendar days 60 calendar days 90 calendar days 120 calendar days 180 calendar days 365 calendar days ENGLISH 0 10 11 12 13 14 UV Lamp Replacement Reminder 0520 Options: Press s / t to set the UV lamp replacement reminder 0 Off 1 365 days 2 730 days 15 69-2485EFS—03 Operating Manual Advanced functions Adaptive Intelligent Recovery 0530 Options: Press s / t to set Adaptive Intelligent Recovery 0 Off 1 On ENGLISH Program schedule periods 0540 Options: Press s / t to set the number of program periods: 2 Twoprogramperiods(Wake,Sleep) 4 Fourprogramperiods(Wake,Leave,Return,Sleep) Heat Energy Saving Setpoint 0615 Options: Press s / t to set the Heat energy savings setpoint 40-90°F 65 4.5-32°C18.5 Cool Energy Saving Setpoint 0616 Options: Press s / t to set the Cool energy savings setpoint 50-99°F 78 10-37°C 25.5 Clock format 69-2485EFS—03 16 TH8320ZW1000 Advanced functions Function 0640 Options: Press s / t to set the clock display format: 12 12-hour clock (i.e., “3:30 pm”) 24 24-hour clock (i.e., “15:30”) 0670 Options: Press s / t to choose a screen lock setting (see page 7): 0 Screen is unlocked (fully functional) 1 All functions locked except temperature controls and CANCEL key 2 Screen is fully locked Z-Wave Inclusion RF10 Options: Press s / t toconnecttoZ-Wavenetwork Exclude Include Share Z-Wave Node Information RF20 Options: Press s / t tosharetheZ-Wavenodeinformation 0 Idle 1 Send node 17 69-2485EFS—03 ENGLISH Screen lock Operating Manual In case of difficulty If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. ENGLISH Display is blank • Checkcircuitbreakerandresetifnecessary. • Makesurepowerswitchatheating&coolingsystemison. • Makesurefurnacedoorisclosedsecurely. No response to key presses (or temperature will not change) • Checktomakesurethethermostatisnotlocked(seepage17). Backlight is dim • IfthermostatisACpowered,adimdisplayisnormal.Thebacklight remains on at a low level, and brightens when a key is pressed. Thermostat shows the calendar screen (year, date, & month) when the power is restored • Thisindicatesthatthecoincellbatteryhasdrainedout.Replacethe coin cell battery immediately. 69-2485EFS—03 • Makesureheatingandcoolingtemperaturesaresettoacceptableranges: • Heat:40°to90°F(4.5°to32°C) • Cool:50°to99°F(10°to37°C) 18 TH8320ZW1000 In case of difficulty Heating or cooling system does not respond • PressSYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. • Checkcircuitbreakerandresetifnecessary. • Makesurepowerswitchatheating&coolingsystemison. • Makesurefurnacedoorisclosedsecurely. • If“Wait”isdisplayed,thecompressorprotectiontimerison.Wait 5 minutes for the system to restart safely, without damaging the compressor. • Thisisnormaloperation.Autoindicatesthethermostatisfollowingthe programmedfansetting.IfAutoandOnisshown,thefanisscheduled for“On”duringthisperiod(seepage7). 19 69-2485EFS—03 ENGLISH Display shows Fan Auto and On or Auto and Circ at the same time • PressSYSTEM to set system to Heat. Make sure the temperature is set higher than the Inside temperature. Operating Manual Regulatory Information FCC Compliance Statement (Part 15.19) (USA only).ThisdevicecomplieswithPart15oftheFCCRules.Operationissubject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only). Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. ENGLISH FCC Interference Statement (Part 15.105 (b)) (USA only). This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: •Reorientorrelocatethereceivingantenna. •Increasetheseparationbetweentheequipmentandreceiver. •Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. •Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Section 7.1.2 of RSS-GEN. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Section 7.1.3 of RSS-GEN.ThisDevicecomplieswithIndustryCanadaLicense-exemptRSSstandard(s).Operationissubjectto the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. 69-2485EFS—03 20 TH8320ZW1000 5-year limited warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’ssoleresponsibilityshallbetorepairorreplacetheproductwithinthetermsstatedabove.HONEYWELLSHALL OTBELIABLEFORANYLOSSORDAMAGEOFANYKIND,INCLUDINGANYINCIDENTALORCONSEQUENTIALDAMAGES RESULTING,DIRECTLYORINDIRECTLY,FROMANYBREACHOFANYWARRANTY,EXPRESSORIMPLIED,ORANYOTHER FAILUREOFTHISPRODUCT.Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,so this limitation may not apply to you. THISWARRANTYISTHEONLYEXPRESSWARRANTYHONEYWELLMAKESONTHISPRODUCT.THEDURATIONOFANY MPLIEDWARRANTIES,INCLUDINGTHEWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE, ISHEREBYLIMITEDTOTHEFIVE-YEARDURATIONOFTHISWARRANTY.Somestatesdonotallowlimitationsonhowlongan implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden alley,MN55422orcall1-800-468-1502.InCanada,writeRetailProductsON15-02H,HoneywellLimited/HoneywellLimitée,35 DynamicDrive,Toronto,OntarioM1V4Z9. 21 69-2485EFS—03 ENGLISH (ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. Z-WaveisaregisteredtrademarkofSigmaDesigns,Inc.and/oritssubsidiaries. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com HoneywellLimited-HoneywellLimitée 35 Dynamic Drive Toronto,OntarioM1V4Z9 ® U.S. Registered Trademark. US Patent No. 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576, and other patents pending. © 2011 Honeywell International Inc. 69-2485EFS—03 M.S. Rev. 05-11 Printed in U.S.A. Mode d’emploi TH8320ZW1000 Thermostatàécrantactile ATTENTION ! N’appuyez jamaissurlestouchesd’unécran tactile avec un instrument pointu tel qu’un stylo ou un crayon. Pour empêcher tout dommage au thermostat, appuyez toujours sur les touches du bout du doigt. M29343 Ce thermostat contient une pile au lithium qui pourrait contenir duperchlorate.Matériaucontenantduperchlorate—des consignesdemanipulationspécialespourraients'appliquer, prière de consulter www.dtsc.ca.gov/hazardouswaste/perchlorate FRANÇAIS Vous faut-il de l’aide ? Pour obtenir de l’assistance concernant ce produit, visitez http://yourhome.honeywell.com ou appelez gratuitement l’assistance client d’Honeywell au 1 800 468-1502 Lisez et sauvez ces instructions. ®U.S.Marquedéposée Brevets US N . 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576 et autres brevets en instance. Copyright©2011HoneywellInternationalInc.Tousdroitsréservés TH8320ZW1000 Table des matières À propos de votre nouveau thermostat Annexes Caractéristiquesduthermostat .................. 2 La programmation en bref .......................... 3 Aide-mémoiresurlescommandes ............. 4 Aide-mémoiresurl’affichage ...................... 5 Encasdedifficultés.................................. 18 Informationsréglementaires ..................... 20 Garantielimitée ......................................... 21 Réglages Réglagedel’horloge ................................... 6 Fonctionnement de la ventilation................ 7 Mode de fonctionnement............................ 8 Ce thermostat est prêt à fonctionner Programmation et fonctionnement Verrouillagedel’écran ................................ 9 Nettoyagedel’écran................................. 10 Changement des piles .............................. 11 Fonctionsévoluées ................................... 12 ATTENTION : RISQUE D’ENDOM-MAGER L’ÉQUIPEMENT. Pourévitertoutrisquededommageau compresseur, ne pas faire fonctionner laclimatisationlorsquelatempérature extérieureestinférieureà10°C(50°F). 69-2485EFS—03 FRANÇAIS Votre nouveau thermostat est préprogramméetprêtàfonctionner.La configuration se trouve à la page 3. Mode d’emploi À propos de du votre thermostat nouveau thermostat Félicitations!Vousvenezd’acheterlethermostatleplusperfectionnéetleplusfacile àutiliserdumonde.Ilestconçupourvousdonnerdenombreusesannéesdeservice fiableetunegrandefacilitédecommanded’ambianceparécrantactile. Caractéristiques FRANÇAIS • Annulationduprogrammeàtoutmomentparcommandedeclimatàunseul bouton. • Commandepréciseduclimatmaintenantlatempératureà1°Fduniveaufixé. • Rappelschanger/vérifierpermettantdesavoiràquelmomentréviserouremplacer lesfiltresouautresélémentsessentiels. • Grandaffichageàtouchestactilesrétro-éclairéfacileàlire,mêmedanslenoir. • LacommandesansfilZ-Wavevouspermetdeconnecterlethermostatàun réseauZ-Wave. 69-2485EFS—03 TH8320ZW1000 À propos Ce thermostat du thermostat est prêt à fonctionner Votrenouveauthermostatestpré-programméetprêtàfonctionner.Ilsuffitderégler l’heureetlejour.Vérifiezensuitelesréglagesci-dessousetmodifiez-lessibesoinest: 1. Réglage de l’horloge ................................................................................. Voir page 6 2. Sélection de la configuration du ventilateur : Pré-réglésurAuto ..... Voir page 7 3. Sélection du mode de fonctionnement : Pré-réglésurChauffage ..... Voir page 8 FRANÇAIS 69-2485EFS—03 Mode d’emploi À propos du thermostat Aide-mémoire des commandes Appuyezsurday(s)pourparamétrerleprogramme Appuyez pour sélectionnerla configuration du ventilateur (voir page 7) Appuyez pour modifier leréglagedela température MON FRANÇAIS Appuyez pour paramétrerle programme (voir page 8) Appuyez pour paramétrer le programme TUE WED THU FRI SAT SUN Appuyez pour avoir d’autrespossibilités (certains modèles haut de gamme seulement) SUN M32520A Appuyez pour annuler le programme 69-2485EFS—03 Appuyez pour réglerl’horloge (voir page 6) Appuyez pour verrouiller le pavénumériquependant30 secondes afin de nettoyer l’écran(voirpage10). TH8320ZW1000 À propos du thermostat Aide-mémoire de l’affichage d’état Températureintérieureactuelle Jour actuel de la semaine Réglagedelatempérature Programme en fonctionnement (ne s’affiche pas lorsqu’il n’est pas en fonctionnement) Réglageventilation Inside Réglagesystème AUTO 70 SCHED HOLD AM CLOCK FRANÇAIS 8:10 HEAT Adaptive Intelligent Recovery Following Schedule SUN SYSTEM Heure actuelle Set To 75 FAN Recovery SCREEN M32521 Autres messages affichés : • Cool On : l’installation de climatisation est en marche • Heat On : l’installation de chauffage est en marche • Aux Heat On :Lesystèmedechauffageauxiliaireestactivé 69-2485EFS—03 Mode d’emploi À proposde Réglage dul’horloge thermostat Pourréglerl’affichagedel’heureactuelle, appuyez sur CLOCK, puis sur s ou t pour modifier l’heure. Appuyez sur s ou t maintenant la pression pour avancer l’heure plus rapidement. Appuyez sur CLOCK WED 6:01 SCHED AM HOLD CLOCK SCREEN MORE M32527 Modifiez l’heure et appuyez sur DONE FRANÇAIS FAN AUTO 70 Inside Set To Remarque : l’horlogetempsréelnedevrait jamaisnécessiterderéglagepuisqu’elle est automatiquement mise à jour lors des changementsentreheured’étéetheured’hiver etmetenmémoiretouslesrenseignements concernant la date et l’heure. 70 WED 6:02 AM DONE Appuyez sur DONE pour sauvegarder et quitter (ou appuyez sur CANCEL pour quitter sans modifier l’heure). Remarque : Pour modifier l’affichage du jour de la semaine actuel, voir la page 13. CANCEL M32528 69-2485EFS—03 TH8320ZW1000 À proposdu Réglage dufonctionnement thermostat de la ventilation Appuyer sur le bouton FANpoursélectionnerle mode de fonctionnement du ventilateur, puis appuyer sur DONE : Inside FAN AUTO 70 SYSTEM HEAT 70 AM HOLD CLOCK Appuyez sur FAN REMARQUE : Si un horaireestprogrammé pour le ventilateur, le ventilateur fonctionnera selon cet horaire lorsqu’il est en mode « Auto ». SCREEN M32529 • Circ : Le ventilateur se met en marche de façonaléatoirependantenviron35%du temps, incluant le temps de fonctionnement lorsque le système de chauffage ou de climatisation est en marche. FRANÇAIS SCHED • Auto : Le ventilateur ne fonctionne que lorsque la chauffage ou la climatisation fonctionne. Following Schedule WED 6:01 • On : Le ventilateur est constamment en marche. Set To Pourdérogerauxréglagesprogramméspourleventilateur enfonctiondechacunedespériodes,appuyersurFAN. Si leventilateurestrégléàOn ou Circ,leréglagesélectionné restera en vigueur jusqu’à ce que l’utilisateur appuie de nouveau sur FANpoursélectionnerlemodedefonctionnement Auto,etreveniràl’horaireprogrammépourleventilateur(pour obtenir d’autres renseignements, aller à la page 19). 69-2485EFS—03 Mode d’emploi À propos du Sélection du thermostat mode de fonctionnement Appuyer sur la touche SYSTEM pour sélectionner,puisappuyersurDONE : Inside FAN AUTO SYSTEM 70 70 6:01 FRANÇAIS SCHED • Cool : Le thermostat ne commande que l’installation de climatisation. Following Schedule WED HEAT • Heat : Le thermostat ne commande que l’installation de chauffage. Set To • Off : Arrêt des installations de chauffage et de climatisation. AM HOLD CLOCK SCREEN M32522 Appuyez sur SYSTEM 69-2485EFS—03 • Auto :Lethermostatsélectionne automatiquement le chauffage ou la climatisation en fonction de la températureintérieure. • Em Heat : (uniquement pour les pompes à chaleur à chauffage auxiliaire) : Le thermostat commande le chauffage auxiliaire. TH8320ZW1000 À propos du de Verrouillage thermostat l’écran Pour empêcher toute modification intempestive, il est possible de verrouiller totalementoupartiellementl’écran. WED SCREEN LOCKED FAN AUTO SYSTEM 70 Inside Set To 70 Following Schedule HEAT 6:00 SCHED PM HOLD CLOCK SCREEN MORE VoirFonctionévoluée0670 (page 17) où figurent les choix screen lock Lorsquel’écranestentièrementverrouillé, aucune touche ne fonctionne. Pour verrouiller oudéverrouillerl’écran,voirfonctionévoluée 0670 à la page 17. 69-2485EFS—03 FRANÇAIS M29357 Lorsqu’ilestpartiellementverrouillé,l’écran affiche SCREEN LOCKED pendant plusieurs secondes si l’on appuie sur une touche verrouillée.Pourdéverrouillerl’écran,appuyez surn’importequelletouchenonverrouillée pendant que SCREEN LOCKED apparaît sur l’écran. Mode d’emploi À propos du Nettoyage dethermostat l’écran Appuyez sur SCREEN Appuyez sur SCREENpourverrouillerl’écran afindelenettoyer.L’écranresteraverrouillé pendant 30 secondes pour permettre de le nettoyersansmodifierlesréglages. WED 6:00 SCHED PM HOLD CLOCK SCREEN Minuteurdeverrouillaged’écran (30 secondes) USAGE M32526 Au bout de 30 secondes, appuyez sur DONE pour reprendre le fonctionnement normal ou appuyez sur SCREEN s’il faut davantage de temps pour nettoyer. FRANÇAIS Remarque : Nejamaispulvériseraucun liquide directement sur le thermostat. Pulvériserleliquidesuruntorchon,puisutiliser cetorchonpournettoyerl’écran.Utiliserde l’eau ou un produit de nettoyage pour du verre. Ne pas utiliser de produits abrasifs. M32523 69-2485EFS—03 10 TH8320ZW1000 Changement des piles Retirez l’onglet. M32429 11 69-2485EFS—03 FRANÇAIS Lethermostatestexpédiédel’usine aveclapileboutoninstallée.Une languetteenplastiqueestinsérée dans le support des piles pour empêcherquelapilenesedécharge durantl’expéditionetl’entreposage. Lalanguettedoitêtreretiréedurant l’installation. Il suffit de tirer sur la languettepourladégagerdusupport de pile. Assurez-vous que le support depileestcomplètementinsérédans le thermostat. Mode d’emploi Fonctions évoluées 1. Appuyez sur SYSTEM. 2. Appuyez sur la touche centrale vide et continuez à le faire jusqu’à ce que l’affichage change. 6:01 SYSTEM SUN HEAT AM DONE CANCEL M32530 M32525 Fonction FRANÇAIS 3. Modifiez les paramètres selon les besoins (voir pages 13 à 17). 0120 Réglage 20 DONE M32531 4. Appuyez sur DONE pour quitter et sauvegarder les modifications. 69-2485EFS—03 12 Appuyez sur st pour sélectionner fonction Appuyez sur st pour modifier le réglage TH8320ZW1000 Fonctions évoluées Programmation de l’année (deux premiers chiffres) Fonction 0120 Choix : Appuyez sur s / t pourmodifierlesdeuxpremierschiffresdel’année. 20 = Année20xx 21 = Année21xx Programmation de l’année (deux derniers chiffres) 0130 Choix : Appuyez sur s / t pourmodifierlesdeuxdernierschiffresdel’année. 01 - 99 (c-à-d. 2001 - 2099) Programmation du mois Appuyez sur s / t pourmodifierlemoisactuellementaffiché. 1-12(c-à-d.Janvier-Décembre) FRANÇAIS 0140 Choix : Programmation de la date 0150 Choix : Appuyez sur s / t pour modifier le date. 1 - 31 Programmation marche/arrêt 0160 Choix : Appuyez sur s / t pour mettre la programmation en marche ou à l’arrêt. 0 N’est pas programmable 4 Programmable 13 69-2485EFS—03 Mode d’emploi Fonctions évoluées Restaurer le calendrier de réduction des dépenses énergétiques Fonction 0165 Choix : Appuyez sur s / t pourrestaurerleprogrammed’économied’énergie 0 Non 1 Oui Rétroéclairage continu 0280 Choix : Appuyez sur s / t pourréglerlerétroéclairagecontinu 0 Non 1 Oui Format de température (°F/°C) FRANÇAIS 0320 Choix : Appuyez sur s / t pour programmer le format de l’affichage : 0 Fahrenheit 1 Celsius Changement horaire été/hiver 0330 Choix : Lethermostatestpréprogrammépoureffectuerautomatiquementlechangement heured’été.Appuyezsurs / t pour selectionner : 0 Arrêt:pasderéglagepourchangementheured’été. 1 Marche : passageautomatiqueàl’heured’été/d’hiver(pourleszonesqui n’utilisentpaslenouveaucalendrieravecheured’été/d’hiver). 69-2485EFS—03 14 TH8320ZW1000 Fonctions évoluées Rappel de remplacement du filtre de la fournaise Fonction 0500 Choix : Appuyez sur s / t pourréglerlerappelderemplacementdufiltre Arrêt Duréedefonctionnementde10jours(environ1mois) Duréedefonctionnementde30jours(environ3mois) Duréedefonctionnementde60jours(environ6mois) Duréedefonctionnementde90jours(environ9mois) Duréedefonctionnementde120jours(environ1an) Duréedefonctionnementde180jours(environ1,5an) Duréedefonctionnementde270jours(environ2ans) Duréedefonctionnementde365jours(environ3ans) 30 jours civils 60 jours civils 90 jours civils 120 jours civils 180 jours civils 365 jours civils FRANÇAIS 1 2 3 4 5 6 7 8 10 11 12 13 14 Rappel de remplacement de la lampe UV 0520 Choix : Appuyez sur s / t to set the UV lamp replacement reminder 0 Arrêt 1 365 jours 2 730 jours 15 69-2485EFS—03 Mode d’emploi Fonctions évoluées Système de récupération intelligent adaptatif Fonction 0530 Choix : Appuyez sur s / t pourréglerlesystèmeAdaptiveIntelligentRecovery Arrêt Marche Plages du programme 0540 Choix : Appuyez sur s / t pour programmer le nombre de plages de programme. 2 Deuxplagesdeprogramme(Wake,Sleep) 4 Quatreplagesdeprogramme(Wake,Leave,Return,Sleep) Point de consigne économisateur d’énergie pour le chauffage FRANÇAIS 0615 Choix : Appuyez sur s / t pourréglerlepointdeconsignedechauffagepourl’économie d’énergie 40-90°F 65 4.5-32°C18.5 Point de consigne économisateur d’énergie pour le refroidissement 0616 Choix : Appuyez sur s / t pourréglerlepointdeconsignederefroidissementpour l’économied’énergie 50-99°F 78 10-37°C 25.5 69-2485EFS—03 16 TH8320ZW1000 Fonctions évoluées Format de l’horloge Fonction 0640 Choix : Appuyez sur s / t pour programmer le format d’affichage de l’horloge. 12 Horloge 12 heures (c.-à-d. 3:30 p.m.) 24 Horloge 24 heures (c.-à-d. 15:30 p.m.) Verrouillage de l’écran 0670 Choix : Appuyez sur s / t pourchoisirunparamètredeverrouillagedel’écran(voirlepage7). Inclusion Z-Wave RF10 Choix : Appuyez sur s / t pourétablirlaconnexionauréseauZ-Wave 0 Exclure 1 Inclure Partage de l’information des nœuds Z-Wave RF20 Choix : Appuyez sur s / t pourpartagerleréseauZ-Wave 0 Veille 1 Envoyer le noeud 17 69-2485EFS—03 FRANÇAIS 0 L’écranestnonverrouillé(entièrementfonctionnel) 1 Touteslesfonctionssontverrouilléessauflacommandedetempératureetla touche CANCEL 2 L’écranesttotalementverrouillé Mode d’emploi À propos En cas dedu difficultés thermostat Sivousrencontrezdesdifficultésavecvotrethermostat,veuillezessayerles suggestions ci-dessous. La plupart des problèmes se corrigent rapidement et facilement. FRANÇAIS L’affichage est vide • Vérifiezledisjoncteuretréenclenchez-le. • Vérifiezquelecommutateurd’alimentationdel’installationde chauffage ou de la climatisation est sur marche. • Vérifiezquelaportedelachaudièreestbienfermée. Rien ne se produit lorsqu’on appuie sur les touches ou la température ne change pas) • Vérifiezquelethermostatn’estpasverrouillé(voirpage17). • Vérifiezquelestempératuresdechauffageetdeclimatisationsont dans des fourchettes acceptables : • Heat:4,5°à32°C(40°à90°F). • Cool:10°à37°C(50°à99°F). Le rétroéclairage est sombre • Silethermostatestalimentéparpiles,unaffichagesombreest normal.Lerétroéclairageresteàunfaibleniveauets’illumine lorsqu’on appuie sur une touche. Le thermostat affiche l’écran calendrier (année, date et mois) lorsque l’alimentation est rétablie. • Celaindiquequelapileboutonestcomplètementàplat. Remplacez-laimmédiatement. 69-2485EFS—03 18 TH8320ZW1000 À propos En cas dedu difficultés thermostat Le chauffage ou la climatisation ne réagit pas. • AppuyezsurlatoucheSYSTEM pour mettre le système sur Chauffage.Vérifiezqueleréglagedetempératureestsupérieuràla températureintérieure. Les mots Fan Auto et On ou Auto et Circ sont affichés à l’écran en même temps • Ils’agitlàdumodedefonctionnementnormal.LemotAUTO signifiequelethermostatrespecteleréglageprogrammépourle ventilateur.SilesmotsAutoetOnsontaffichés,leventilateurest normalementenmarcheaucoursdecettepériode(voirlapage7). 19 69-2485EFS—03 FRANÇAIS • AppuyezsurlatoucheSYSTEM pour mettre le système sur Climatisation.Vérifiezqueleréglagedetempératureestinférieurà latempératureintérieure. • Vérifiezledisjoncteuretleréenclenchersinécessaire. • Vérifiezquelecommutateurd’alimentationdusystèmede chauffage et de climatisation est en marche. • Vérifiezquelaportedelachaudièreestbienfermée. • Si«Wait»estaffiché,leminuteurdeprotectionducompresseur estenmarche.Attendez5minutespourquelesystèmeredémarre entoutesécuritésansendommagerlecompresseur. Mode d’emploi Informations réglementaires Déclaration de conformité de la FCC (Partie 15.19) (États-Unis uniquement) Ce dispositif est conforme à la Partie 15 du règlement de la FCC. Le fonctionnement est soumis aux deux conditions suivantes :1)Cedispositifnedoitpascauserd’interférencesnuisibles,et;2)Cedispositifdoitacceptertouteslesinterférencesreçues,y compriscellespouvantcauserunfonctionnementnonsouhaité. Avertissement de la FCC (Partie 15.21) (États-Unis uniquement) Leschangementsetlesmodificationsnonexpressémentapprouvésparlapartieresponsabledelaconformitépeuventannuler l’autoritédel’utilisateuràutiliserl’équipement. FRANÇAIS Déclaration d’interférence de la FCC (Partie 15.105 (b)) (États-Unis uniquement) CetéquipementaététestéetestconformeauxlimitesdesdispositifsnumériquesdeClasseB,conformémentàlaPartie15 durèglementdelaFCC.Ceslimitessontconçuespourfourniruneprotectionraisonnablecontrelesinterférencesnuisibles dansuneinstallationrésidentielle.Cetéquipementgénère,utiliseetpeutémettredel’énergiederadiofréquence,ets’iln’est pasinstalléetutiliséconformémentauxinstructions,peutcauserdesinterférencesnuisiblesauxcommunicationsradio.Iln’y atoutefoisaucunegarantiequ’uneinterférencen’aurapaslieudansuneinstallationparticulière.Sicetéquipementcausedes interférencesnuisiblesàlaréceptionradioettélévision,cequipeutêtredéterminéenéteignantledispositifetenleremettant enmarche,ilestrecommandéàl’utilisateurdetenterdecorrigerl’interférenceparl’unedesmesuressuivantes: •Réorienteroudéplacerl’antenneréceptrice. •Augmenterlaséparationentrel’équipementetlerécepteur. •Brancherl’équipementdanslaprised’uncircuitdifférentdeceluiauquellerécepteurestconnecté. •Consulterledistributeurouuntechnicienradio/TVcompétentpourobtenirdel’aide. Section 7.1.3 de RSS-GEN. Lefonctionnementestsoumisàdeuxconditions:1)Cedispositifnedoitpascauserd’interférences,et;2)Cedispositifdoit acceptertouteslesinterférences,ycompriscellespouvantcauserunfonctionnementnonsouhaité. Section 7.1.2 de RSS-GEN. Conformémentàlalégislationd’IndustrieCanada,l’émetteurradioélectriquenepeutfonctionnerqu’avecuneantennedetype etdegainmaximum(oumoins)approuvéspourletransmetteurparIndustrieCanada.Pourréduirelepotentield’interférence radioélectriquepourd’autresutilisateurs,letyped’antenneetsongaindoiventêtrechoisispourquelapuissanceisotrope rayonnéeéquivalente(PIRE)soitlimitéeàcellejusterequisepourobtenirunebonnecommunication. 69-2485EFS—03 20 TH8320ZW1000 Garantie limitée de 5 ans Honeywell garantit ce produit, à l’exception des piles, contre tout vis de fabrication ou de matière dans des conditions d’utilisationetdeservicenormales,pendantuneduréedecinq(5)ansàcompterdeladated’achatparleconsommateur.Siàun momentquelconquependantladuréedelagarantie,leproduitestjugédéfectueuxoutombeenpanne,Honeywellleréparera ou le remplacera (au choix d’Honeywell). Sileproduitestdéfectueux, (i)retournez-leavecunreçuouuneautrepreuved’achataulieuoùvousl’avezacheté,ou (ii)appelezleserviceclientsd’Honeywellau1-800-468-1502.Leserviceclientdéciderasileproduitdoitêtrerenvoyéàl’adresse suivante : Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, ou si un produit de remplacementpeutvousêtreenvoyé. Cettegarantienecouvrepaslesfraisdedémontageouderéinstallation.Ellenes’appliquepassiHoneywellprouvequele défautouladéfaillanceprovientdedommagesquisesontproduitspendantqueleproduitétaitdanslapossessiond’un acquéreur. CETTEGARANTIEESTLASEULEGARANTIEEXPLICITEQUEFAITHONEYWELLSURCEPRODUIT.LADURÉEDETOUTES LESGARANTIESIMPLICITES,YCOMPRISCELLESDEQUALITÉMARCHANDEETD’ADAPTATIONÀUNUSAGEPARTICULIER ESTLIMITÉEPARLADURÉEDECINQANSDECETTEGARANTIE.Certainsétatsnepermettentpasdelimitessurladurée d’une garantie implicite, il se peut donc que les limites ci-dessus ne s’appliquent pas à vous. Cettegarantievousdonnedesdroitsspécifiquesfaceàlaloietvouspouvezenavoird’autres,variablesd’unétatàunautre. Sivousavezdesquestionsconcernantcettegarantie,écrivezàHoneywellCustomerRelations,1985DouglasDr,GoldenValley, MN55422ouappelez1-800-468-1502.AuCanada,écrivezàRetailProductsON15-02H,HoneywellLimited/HoneywellLimitée, 35DynamicDrive,Toronto,OntarioM1V4Z9. 21 69-2485EFS—03 FRANÇAIS Laresponsabilitéd’Honeywellselimiteàlaréparationouauremplacementduproduitdanslesconditionsénoncéescidessus. HONEYWELLNESAURAITÊTRETENURESPONSABLED’UNEPERTEOUDEDOMMAGESQUELSQU’ILSSOIENT,Y COMPRISLESDOMMAGESCONSÉCUTIFSOUACCESSOIRESPROVENANTDIRECTEMENTOUINDIRECTEMENTD’UNE INFRACTIONÀLAGARANTIEEXPLICITEOUIMPLICITEOUDETOUTEAUTREDÉFAILLANCEDECEPRODUIT.Certains étatsnepermettentpasl’exclusionoulalimitationdesdommagesaccessoiresousecondaires;cettelimitationpeutnepas s’appliquer à vous. Z-WaveestunemarquedecommercedéposéedeSigmaDesigns,Inc.et/oudesesfiliales. Solutions de régulation et d’automatisation Honeywell International Inc 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com HoneywellLimited-HoneywellLimitée 35, promenade Dynamic Toronto(Ontario)M1V4Z9 ®MarquedecommercedéposéeauxÉ.-U. Brevets US N0. 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576 et autres brevets en instance. © 2011 Honeywell International Inc. 69-2485EFS—03 M.S. Rev. 05-11 ImpriméauxÉtats-Unis Manual de Uso TH8320ZW1000 Termostato con pantalla activada por tacto ¡TENGA CUIDADO! Nunca utilice instrumentos con punta afilada, como un lápiz o bolígrafo para oprimir las teclas de la pantalla activada por tacto. Para evitar dañar el termostato, siempre oprima las teclas con la punta del dedo. M29343 Este termostato tiene una batería de litio que puede contener perclorato. Perclorato:puedesernecesariomanipularloconmétodos especiales. Visite www.dtsc.ca.gov/hazardouswaste/perchlorate. ¿Necesita ayuda? Para recibir asistencia con este producto visite http://yourhome.honeywell.com o llame gratis al Servicio de Atención al Cliente Honeywell al 1-800-468-1502 ESPAÑOL Lea y conserve estas instrucciones ® Marca registrada en EE.UU. Patente en EE.UU: Nº 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576 y otras patentes pendientes. Copyright © 2011 Honeywell International Inc. Todos los derechos reservados. TH8320ZW1000 Índice de contenidos Acerca de su nuevo termostato Apéndices Funciones del termostato ........................... 2 Programación a simple vista ...................... 3 Referencia rápida de los controles ............. 4 Referencia rápida de la pantalla ................. 5 En caso de dificultades ............................ 18 Información regulatoria ............................. 20 Garantía limitada ....................................... 21 Ajustes Ajuste del reloj ............................................ 6 Ajuste del ventilador ................................... 7 Ajuste del sistema....................................... 8 ¡Este termostato está listo para usar! El nuevo termostato viene preprogramado y listo para usar. Ver página 3 para verificar los ajustes. Programación y operación Bloqueo de pantalla .................................... 9 Limpieza de pantalla ................................. 10 Reemplazo de baterías ............................. 11 Funciones avanzadas ............................... 12 69-2485EFS—03 ESPAÑOL PRECAUCIÓN: PELIGRO DE DAÑO DEL EQUIPO. Para impedir un posible daño al compresor, no haga funcionar el sistema de refrigeración cuando la temperatura exteriorseainferiora50°F(10°C). Manual de Uso Acerca de su nuevo termostato ¡Felicitaciones! Usted acaba de comprar el termostato más avanzado y más fácil de usar en todo el mundo. Ha sido diseñado para brindarle muchos años de servicio confiable y control del clima con sólo tocar la pantalla. Funciones • Elcontroldetemp.deunsólotoqueanulaelcronogramaprogramadoen cualquier momento. • Precisocontroldecomodidadquemantienelatemperaturadentrodelrangode 1ºF del nivel que usted fije. • Recordatoriosparacambiar/controlarleavisancuandorevisaroreemplazarlos filtros y otros componentes cruciales. • Lapantallagrandesensiblealtactoconiluminaciónposterioresfácildeleer, incluso en la oscuridad. • ElcontrolinalámbricoZ-WavelepermiteconectareltermostatoaunaredZ-Wave. ESPAÑOL 69-2485EFS—03 TH8320ZW1000 Este termostato está listo para usar! El nuevo termostato viene preprogramado y listo para usar. Todo lo que tiene que hacer es ajustar la hora y el día. Luego verifique los siguientes ajustes y cámbielos si es necesario: 1. Ajuste la hora .............................................................................................Ver página 6 2. Seleccione el ajuste del ventilador: Predeterminado en Auto .............Ver página 7 3. Seleccione el ajuste del sistema: Predeterminado en Heat .................Ver página 8 ESPAÑOL 69-2485EFS—03 Manual de Uso Referencia rápida de los controles Oprimaeldíaolosdíasparaajustarelhorariodeprograma Oprimapara seleccionar el funcionamiento del ventilador (ver página 7) MON Presione este botón para configurar el cronograma (ver página 8) ESPAÑOL Oprimapara ajustar el cronograma del programa 69-2485EFS—03 TUE WED THU FRI SAT SUN Oprimapara ajustar la configuración de temperatura Oprimaparamás opciones (ciertos modelos únicamente) SUN M32520A Oprimapara anular el cronograma del programa Oprimapara ajustar el reloj (ver página 6) Oprimaparabloquearel teclado durante 30 segundos para limpiar la pantalla (ver página 10) TH8320ZW1000 Referencia rápida de la pantalla Día de la semana actual Temperatura interior actual Ajuste de temperatura Cronograma del programa activado (no aparece cuando está desactivado) Ajustes del ventilador Inside 75 FAN Ajustes del sistema AUTO SUN SYSTEM 8:10 HEAT SCHED HOLD AM CLOCK Set To 70 Adaptive Intelligent Recovery activado Following Schedule Recovery SCREEN Hora actual M32521 ESPAÑOL Otros mensajes de pantalla: • Cool On: el sistema de refrigeración está activado • Heat On: el sistema de calefacción está activado • Aux Heat On: el sistema de calefacción auxiliar está activado 69-2485EFS—03 Manual de Uso Ajuste del reloj OprimaCLOCK 6:01 SCHED Para ajustar la hora actual en pantalla, oprima CLOCK, luego oprima s o t para ajustar la hora. Mantenga oprimido s o t para avanzar la hora con más rapidez. WED AM HOLD CLOCK SCREEN MORE M32527 Ajuste la hora, luego oprima DONE FAN AUTO 70 Inside Set To Nota: el reloj de hora-real no debería requerir ajuste nunca ya que se actualiza automáticamente de acuerdo al horario de ahorro de energía diurno, y guarda toda la información de fecha/hora. 70 Nota: para cambiar el día actual de la semana en pantalla, ver página 13. WED ESPAÑOL 6:02 OprimaDONE para guardar y salir (u oprima CANCEL para salir sin cambiar la hora). AM DONE CANCEL M32528 69-2485EFS—03 TH8320ZW1000 Ajustes del ventilador OprimaFAN (ventilador) para seleccionar la función de ventilador; luego, oprima DONE (listo): Inside FAN AUTO 70 SYSTEM HEAT SCHED • Auto: el ventilador funciona sólo cuando el sistema de calefacción o de refrigeración está encendido. 70 Following Schedule WED 6:01 • On: el ventilador está siempre encendido. Set To AM HOLD CLOCK SCREEN M32529 OprimaFAN Puede presionar el botón FAN (ventilador) para anular las configuraciones del ventilador que ha programado para distintos períodos. Si selecciona On (encendido) o Circ (circulante), la configuración que ha seleccionado permanecerá activa hasta que presione FAN (ventilador) nuevamente para seleccionar Auto (automático) y regresar al cronograma del ventilador (vea la página 19 para obtener más información). 69-2485EFS—03 ESPAÑOL Nota: si se programa un cronograma del ventilador, el modo ‘Auto’ (automático) lo ejecutará. • Circ: el ventilador funciona de forma aleatoria, aproximadamente el 35% del tiempo, incluso en momentos en que el sistema de calefacción o de refrigeración estéfuncionando. Manual de Uso Ajustes del sistema OprimaelbotónSYSTEM (sistema) para realizar la selección; luego, oprima DONE (listo): Inside FAN AUTO SYSTEM 70 70 6:01 SCHED • Cool: el termostato controla sólo el sistema de refrigeración. Following Schedule WED HEAT • Heat: el termostato controla sólo el sistema de calefacción. Set To • Off: los sistemas de calefacción y refrigeración están apagados. AM HOLD CLOCK SCREEN M32522 OprimaSYSTEM • Auto: el termostato selecciona automáticamente la calefacción o refrigeración de acuerdo a la temperatura interior. ESPAÑOL • Em Heat: (sólo para bombas de calefacción con calefacción auxiliar). El termostato controla la calefacción de emergencia y la auxiliar. 69-2485EFS—03 TH8320ZW1000 Bloqueo de pantalla Para prevenir alteraciones no deseadas, la pantalla se puede bloquear parcial o totalmente. WED SCREEN LOCKED FAN AUTO SYSTEM 70 Inside Set To 70 Cuando está parcialmente bloqueada, la pantalla muestra el mensaje SCREEN LOCKED durante varios segundos si se oprime una tecla bloqueada. Para desbloquear la pantalla, oprimacualquierteclaquenoestébloqueada mientras SCREEN LOCKED aparece en pantalla. Following Schedule HEAT 6:00 SCHED PM HOLD CLOCK SCREEN MORE M29357 Vea la función avanzada 0670 (página 17) para las opciones de bloqueo de pantalla Cuando la pantalla está totalmente bloqueada, ninguna tecla funciona. Para desbloquear la pantalla, vea la función avanzada 0670 en la página 17. ESPAÑOL 69-2485EFS—03 Manual de Uso Limpieza de pantalla OprimaSCREEN OprimaSCREEN para bloquear la pantalla para limpiarla. La pantalla permanecerá bloqueada durante 30 segundos para que pueda limpiarla sin cambiar los ajustes. WED 6:00 SCHED PM HOLD CLOCK SCREEN USAGE M32526 Temporizador de bloqueo de pantalla (30 segundos) Despuésde30segundos,oprimaDONE para reanudar el funcionamiento normal, u oprima SCREEN nuevamente si necesita más tiempo para limpiar. Nota: No rocíe ningún líquido directamente sobre el termostato. Rocíe los líquidos en un paño, luego use el paño húmedo para limpiar la pantalla. Utilice agua o limpiavidrios doméstico.Eviteloslimpiadoresabrasivos. ESPAÑOL M32523 69-2485EFS—03 10 TH8320ZW1000 Reemplazo de baterías Retire la lengüeta. M32429 11 69-2485EFS—03 ESPAÑOL El termostato se envía con la batería tipo botón instalada en fábrica. Para evitar que la batería se descargue durante el envío y almacenaje, el termostato se envía con una lengüeta plástica insertada en el alojamiento de la batería. Esta lengüeta debe retirarse durante la instalación. Simplemente hale la lengüeta plástica para extraerla de la bandeja de la batería. Cerciórese dequelabandejadelabateríaesté completamente insertada en el termostato. Manual de Uso Funciones avanzadas 1. OprimaSYSTEM. 2. Mantenga oprimida la tecla vacía del centro hasta que cambie la pantalla. 6:01 SYSTEM SUN HEAT AM DONE CANCEL M32530 M32525 Función 3. Cambie los ajustes según sea necesario (ver páginas 13-17). Ajuste 0120 20 Oprimast para seleccionar la función Oprimast para cambiar los ajustes DONE ESPAÑOL 4. OprimaDONE para salir y guardar los ajustes. 69-2485EFS—03 12 M32531 TH8320ZW1000 Funciones avanzadas Ajuste de año (primeros dos dígitos) Función 0120 Oprimas / t para cambiar los primeros dos dígitos del año: Opciones: 20 = Año 20xx 21 = Año 21xx Ajuste de año (segundos dos dígitos) 0130 Opciones: Oprimas / t para cambiar los últimos dos dígitos del año: 01 - 99 (ej., 2001 - 2099) Ajuste de mes 0140 Opciones: Oprimas / t para cambiar el mes actual: 1 - 12 (ej., Enero - Diciembre) Ajuste de fecha 0150 Opciones: Oprimas / t para cambiar la fecha actual: 1 - 31 Cronograma de programas on/off Opciones: Oprima s / t para encender o apagar el cronograma de programas: No es programable Programable 13 69-2485EFS—03 ESPAÑOL 0160 Manual de Uso Funciones avanzadas Restituya la programación de ahorro de energía Función 0165 Presione s / t para restituir el cronograma de ahorro de energía Opciones: 0 No 1 Sí Iluminación posterior continua 0280 Opciones: Presione s / t para configurar la luz de fondo continua 0 No 1 Sí Formato de temperatura (°F/°C) 0320 Opciones: Oprimas / t para ajustar el formato devisualización de temperatura: 0 Fahrenheit 1 Centígrados Cronograma de ahorro de energía on/off 0330 ESPAÑOL Opciones: El termostato está preprogramado para ajustarse automáticamente al cronograma de ahorrodeenergíadiurno.Oprimas / t para seleccionar: 0 Off:Sinajusteparacronogramadeahorrodeenergíadiurno. 1 On:Cambio automático al horario de verano (para áreas que no utilizan el nuevo calendario DST). 69-2485EFS—03 14 TH8320ZW1000 Funciones avanzadas Recordatorio de cambio del filtro del equipo de calefacción Función 0500 Presione s / t para configurar la luz de fondo continua Opciones: 0 Desactivado 1 Tiempo de funcionamiento de 10 días (aproximadamente 1 mes) 2 Tiempo de funcionamiento de 30 días (aproximadamente 3 meses) 3 Tiempo de funcionamiento de 60 días (aproximadamente 6 months) 4 Tiempo de funcionamiento de 90 días (aproximadamente 9 months) 5 Tiempo de funcionamiento de 120 días (aproximadamente 1 año) 6 Tiempo de funcionamiento de 180 días (aproximadamente 1.5 años) 7 Tiempo de funcionamiento de 270-day días (aproximadamente 2 años) 8 Tiempo de funcionamiento de 365-day días (aproximadamente 3 años) 9 30 días calendario 10 60 días calendario 11 90 días calendario 12 120 días calendario 13 180 días calendario 14 365 días calendario Recordatorio de reemplazo de lámpara UV Presione s / t para configurar el recordatorio de reemplazo de la lámpara UV 0 Desactivado 1 365 días 2 730 días 15 69-2485EFS—03 ESPAÑOL 0520 Opciones: Manual de Uso Funciones avanzadas Sistema de recuperación inteligente adaptativo Función 0530 Presione s / t para configurar Adaptive Intelligent Recovery Opciones: 0 Desactivado 1 Activada Períodos de cronograma de programas 0540 Opciones: Oprima s / t para fijar la cantidad de períodos de programas: 2 Dosperíodosdeprograma(Wake,Sleep) 4 Cuatroperíodosdeprograma(Wake,Leave,Return,Sleep) Punto de referencia para ahorro de energía de calefacción 0615 Opciones: Presione s / t para configurar el punto de ajuste de ahorro de energía de calefacción 40-90°F 65 4.5-32°C18.5 Punto de referencia para ahorro de energía de refrigeración 0616 ESPAÑOL Opciones: Presione s / t para configurar el punto de ajuste de ahorro de energía de refrigeración 50-99°F 78 10-37°C 25.5 69-2485EFS—03 16 TH8320ZW1000 Funciones avanzadas Formato de reloj Función 0640 Oprima s / t para ajustar el formato de visualización del reloj: Opciones: 12 Horario de 12 horas (ej.: “3:30 PM”) 24 Horario de 24 horas (ej.: “15:30 PM”) Bloqueo de pantalla 0670 Opciones: Oprimas / t para elegir una opción de bloqueo de pantalla (ver p. 7): 0 Teclado desbloqueado (totalmente funcional) 1 Todas bloqueadas excepto los controles de temperatura y la tecla CANCEL 2 Pantalla totalmente bloqueada Inclusión Z-Wave RF10 Opciones: Presione s / t paraconectaralaredZ-Wave 0 Excluya 1 Incluya Comparta la información del nodo Z-Wave RF20 Presione s / t paracompartirlaredZ-Wave ESPAÑOL Opciones: Inactivo Enviar al nodo 17 69-2485EFS—03 Manual de Uso En caso de dificultades Si usted tiene dificultades con su termostato, pruebe las sugerencias que figuran a continuación. La mayoría de los problemas se pueden solucionar rápida y fácilmente. Pantalla en blanco No responde cuando se oprimen las teclas (o la temperatura no cambia) • Verifiqueeldisyuntoryreiniciesiesnecesario. • Asegúresedequeestéencendidoelinterruptordelsistemade calefacción y refrigeración. • Asegúresedequeestébiencerradalapuertadelaestufa. • Fíjesequeeltermostatonoestébloqueado(verpágina17). • Asegúresedequelastemperaturasdecalefacciónyrefrigeración se fijen en los rangos adecuados: • Heat:40°a90°F(4.5°a32°C). • Cool:50°a99°F(10°a37°C). ESPAÑOL La iluminación posterior es muy débil • SieltermostatosealimentaconCA,esnormalquelaluzdela pantallaseadébil.Lailuminaciónposteriorpermaneceenunnivel bajo y se intensifica cuando se oprime una tecla. El termostato muestra la pantalla del calendario (año, fecha y mes) cuando se restituye la electricidad • Estoindicaquelabateríatipobotónsehaagotado.Reemplacela batería tipo botón inmediatamente. 69-2485EFS—03 18 TH8320ZW1000 En caso de dificultades No responde el sistema de calefacción o de refrigeración • OprimaSYSTEM para fijar en sistema en Calefacción. Asegúrese de que la temperatura de ajuste sea mayor que la temperatura interior. • OprimaSYSTEM para fijar en sistema en Refrigeración. Asegúrese de que la temperatura de ajuste sea menor que la temperatura interior. • Verifiqueeldisyuntoryreiniciesiesnecesario. • Asegúresedequeestéencendidoelinterruptordelsistemade calefacción y refrigeración. • Asegúresedequeestébiencerradalapuertadelaestufa. • Si“Wait”apareceenpantalla,eltemporizadordeproteccióndel compresor está funcionando. Aguarde 5 minutos a que el sistema se reinicie de modo seguro, sin dañar el compresor. • Estefuncionamientoesnormal.Auto(automático)indicaqueel termostato sigue la configuración programada del ventilador. Si estáenAuto(automático)yOn(encendido),yelventiladorqueda programadoenOnduranteesteperíodo(vealapágina7). 19 69-2485EFS—03 ESPAÑOL La pantalla muestra Fan Auto (ventilador automático) y On (encendido) o Auto (automático) y Circ. (circulante) al mismo tiempo Manual de Uso Información reguladora Declaración de conformidad con las regulaciones FCC (Sección 15.19) (solo en los EE. UU.) Este dispositivo cumple con la Sección 15 de las regulaciones FCC. El funcionamiento está sujeto a las dos condiciones siguientes: 1) Este dispositivo no debe causar interferencia perjudicial. 2) Este dispositivo deberá aceptar cualquier interferencia que se reciba, incluso la interferencia que pudiese causar el funcionamiento no deseado. Advertencia de la FCC (Sección 15.21) (solo en los EE. UU.) Los cambios o las modificaciones que no hayan sido expresamente aprobados por la parte responsable del cumplimiento de las regulaciones podrían anular la autoridad del usuario para hacer funcionar el equipo. Declaración de la FCC sobre interferencias (Sección 15.105 (b)) (solo en los EE. UU.) Este equipo fue probado y cumple con los límites de los dispositivos digitales clase B, conforme a la Sección 15 de las regulaciones FCC. Estos límites están diseñados para ofrecer una protección razonable contra la interferencia perjudicial en una instalación residencial. Este equipo genera usos y puede irradiar energía de frecuencia de radio y, si no se instala y se utiliza según las instrucciones, puede producir una interferencia perjudicial en la comunicación radial. Sin embargo, no se garantiza que no habrá interferencia en una instalación particular. Si este equipo produce una interferencia perjudicial en la recepción televisiva o radial, lo cual puede determinarse al apagar y encender el equipo, se recomienda que el usuario intente corregir la interferencia con una o más de las siguientes medidas: •Vuelvaaorientaryubicarlaantenareceptora. •Aumenteladistanciaentreelequipoyelreceptor. •Conecteelequipoauntomacorrienteenuncircuitodiferenteaaquelenelqueestáconectadoelreceptor. •Consulteconsudistribuidoroconuntécnicoexpertoenradio/televisiónpararecibirayuda. Sección 7.1.3 de RSS-GEN El funcionamiento está sujeto a las dos condiciones siguientes: 1) Este dispositivo no debe causar interferencia. 2) Este dispositivo deberá aceptar cualquier interferencia, incluso la interferencia que pudiese causar el funcionamiento no deseado del dispositivo. ESPAÑOL Sección 7.1.2 de RSS-GEN De acuerdo con las regulaciones de la industria de Canadá, este transmisor de radio puede funcionar únicamente utilizando un tipo de antena y una ganancia máxima (o inferior) aprobada para el transmisor por la industria de Canadá. Para disminuir la interferencia potencial del radio con otros usuarios, el tipo de antena y su ganancia deben ser elegidas de tal forma que la potencia isotrópa radiada equivalente (e.i.r.p.) no sea mayor de lo necesario para una comunicación eficaz. 69-2485EFS—03 20 TH8320ZW1000 Garantía limitada de 5 años Honeywell garantiza que, a excepción de la batería y en condiciones de uso y servicio normales, este producto no tendrá defectos de fabricación ni de materiales durante cinco (5) años a partir de la fecha de compra por parte del consumidor. Si durante ese período de garantía, el producto resulta defectuoso o tiene problemas de funcionamiento, Honeywell lo reparará o reemplazará (a criterio de Honeywell). Si el producto es defectuoso: (i)devuélvalo,acompañadodelafacturauotrapruebadecompraconfecha,allugardondeloadquirió;o (ii)llamealnumérodeatenciónalclientedeHoneywellal1-800-468-1502.Atenciónalclientedeterminarásielproductosedebe devolver a la siguiente dirección: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas, Dr. N. Golden Valley, MN 55422 o bien, si se le puede enviar un producto de reemplazo. Esta garantía no cubre los costos de remoción o reinstalación. Esta garantía no corresponde si Honeywell prueba que el defecto o mal funcionamiento ha sido ocasionado por daño producido mientras el producto estaba en manos de un consumidor. LaúnicaresponsabilidaddeHoneywellserárepararoreemplazarelproductoenelmarcodelostérminosprecedentemente mencionados.HONEYWELLNOSERÁRESPONSABLEPORNINGUNAPÉRDIDANIDAÑOSDENINGÚNTIPO,INCLUSO DAÑOSINCIDENTALESOCONSECUENTESQUERESULTEN,DIRECTAOINDIRECTAMENTEDELINCUMPLIMIENTODE CUALQUIERGARANTÍA,EXPRESAOIMPLÍCITA,ODENINGUNAOTRAFALLADEESTEPRODUCTO.Algunosestadosno admiten la exclusión o limitación de los daños incidentales o consecuentes, de manera que tal vez esta limitación no se aplique en su caso. ÉSTAESLAÚNICAGARANTÍAEXPRESADEHONEYWELLRESPECTODEESTEPRODUCTO.LADURACIÓNDELAS GARANTÍASIMPLÍCITAS,INCLUSOLADECOMERCIABILIDADYDEAPTITUDPARAUNUSOPARTICULAR,SELIMITAPOR ELLOALADURACIÓNDECINCOAÑOSDEESTAGARANTÍA.Algunosestadosnoadmitenlimitacionesencuantoaladuración de las garantías implícitas, de manera que tal vez la limitación precedente no se aplique en su caso. Esta garantía le otorga derechos legales específicos y puede gozar de otros derechos que varían de un estado al otro. 21 69-2485EFS—03 ESPAÑOL Si desea consultar acerca de esta garantía, escriba a Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 ollameal1-800-468-1502.EnCanadá,escribaaRetailProductsON15-02HHoneywellLimited/HoneywellLimitée,35Dynamic Drive,Toronto,OntarioM1V4Z9. Z-WaveesunamarcacomercialregistradadeSigmaDesigns,Inc.y/osussubsidiarias. Automatización y control desenlace Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com HoneywellLimited-HoneywellLimitée 35 Dynamic Drive Toronto,OntarioM1V4Z9 ® Marca registrada de los EE. UU. © 2011 Honeywell Internacional Inc. Patente en EE.UU: Nº 6,574,581, 6,975,958, 7,114,554, 7,346,467, 7,636,604, 7,693,582, 7,788,936, 7,845,576 y otras patentes pendientes. 69-2485EFS—03 M.S. Rev. 05-11 Impreso en EE. UU.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Author : Honeywell ECC Technical Communications Create Date : 2011:05:06 11:01:44-05:00 Modify Date : 2011:05:06 13:06:23-05:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2011:05:06 13:06:23-05:00 Creator Tool : Adobe InDesign CS5 (7.0) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 8677 bytes, use -b option to extract), (Binary data 9344 bytes, use -b option to extract) Instance ID : uuid:33dec076-284e-fa49-a19b-7afc9bc30049 Original Document ID : adobe:docid:indd:5f056a77-4554-11de-a416-cbee6f0ca5a6 Document ID : xmp.did:3E9C15B10D2068118A6D99B682E5C911 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:DFC24B710D2068118A6D99B682E5C911 Derived From Document ID : adobe:docid:indd:5f056a77-4554-11de-a416-cbee6f0ca5a6 Derived From Original Document ID: adobe:docid:indd:5f056a77-4554-11de-a416-cbee6f0ca5a6 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:F0205F74072068118A6D99B682E5C911, xmp.iid:F1205F74072068118A6D99B682E5C911, xmp.iid:DEC24B710D2068118A6D99B682E5C911, xmp.iid:DFC24B710D2068118A6D99B682E5C911, xmp.iid:3E9C15B10D2068118A6D99B682E5C911, xmp.iid:8F4A4F740720681188C69939C7D86886, xmp.iid:87D13474072068118C14E1C2A5F693F8, xmp.iid:7E882A26082068118C14E1C2A5F693F8, xmp.iid:291F9AD8092068118C14E1C2A5F693F8, xmp.iid:267A05100B2068118C14E1C2A5F693F8, xmp.iid:F818D80B102068118C14E1C2A5F693F8, xmp.iid:E06EDA2C112068118C14E1C2A5F693F8, xmp.iid:FBD6345D142068118C14E1C2A5F693F8, xmp.iid:ECD4BCF6152068118C14E1C2A5F693F8, xmp.iid:44301D16192068118C14E1C2A5F693F8, xmp.iid:572B92E71C2068118C14E1C2A5F693F8, xmp.iid:D72F51BC1F2068118C14E1C2A5F693F8, xmp.iid:2233CF1D202068118C14E1C2A5F693F8, xmp.iid:2333CF1D202068118C14E1C2A5F693F8, xmp.iid:941A2D74072068118C14DF07077CD8D7, xmp.iid:5F5CD6EF0E2068118C14DF07077CD8D7, xmp.iid:9B625F540F2068118C14DF07077CD8D7, xmp.iid:F0B2DBA1102068118C14DF07077CD8D7, xmp.iid:655B5DF82B2068118C14DF07077CD8D7, xmp.iid:5D1FDEB53C2068118C14DF07077CD8D7, xmp.iid:98693674072068118C14957431990C5D, xmp.iid:D2D86974072068118C14CA8DD18F89BB, xmp.iid:D3E8F9B3082068118C14CA8DD18F89BB, xmp.iid:5BCBD8CE092068118C14CA8DD18F89BB, xmp.iid:32B5053E0A2068118C14CA8DD18F89BB, xmp.iid:38DF410E0C2068118C14CA8DD18F89BB, xmp.iid:D67D908C0C2068118C14CA8DD18F89BB, xmp.iid:5BD7D33E0D2068118C14CA8DD18F89BB, xmp.iid:5DD546A20D2068118C14CA8DD18F89BB, xmp.iid:4CD8DD340E2068118C14CA8DD18F89BB, xmp.iid:AC824B780F2068118C14CA8DD18F89BB, xmp.iid:B9FAED14102068118C14CA8DD18F89BB, xmp.iid:94C25692102068118C14CA8DD18F89BB, xmp.iid:4EE77892122068118C14CA8DD18F89BB, xmp.iid:6399D24F132068118C14CA8DD18F89BB, xmp.iid:28599E91142068118C14CA8DD18F89BB, xmp.iid:916243E5142068118C14CA8DD18F89BB, xmp.iid:C1D6241C152068118C14CA8DD18F89BB, xmp.iid:C2D6241C152068118C14CA8DD18F89BB, xmp.iid:5E275F682A2068118C14CA8DD18F89BB, xmp.iid:F5DFC4C20A2068118C1493D0956E7BC8, xmp.iid:FF8A3CBD322068118C14D2A2A92C7357, xmp.iid:F6A09E67332068118C14D2A2A92C7357, xmp.iid:ACE19FBD352068118C14D2A2A92C7357, xmp.iid:5BD98108362068118C14D2A2A92C7357, xmp.iid:E04106A9542268118C14D2A2A92C7357, xmp.iid:1B69BA40572268118C14D2A2A92C7357, xmp.iid:D2533631592268118C14D2A2A92C7357, xmp.iid:5CF700D35C2268118C14D2A2A92C7357, xmp.iid:647A77775E2268118C14D2A2A92C7357, xmp.iid:18A52E77612268118C14D2A2A92C7357, xmp.iid:27737812F735E011AD99E6B16ABDD913, xmp.iid:28737812F735E011AD99E6B16ABDD913, xmp.iid:9BF0E886F735E011AD99E6B16ABDD913, xmp.iid:7C6BB57CF835E011AD99E6B16ABDD913, xmp.iid:946C2B0AFA35E011AD99E6B16ABDD913, xmp.iid:2C9A67EFFC35E011AD99E6B16ABDD913, xmp.iid:17C9F4FCFC35E011AD99E6B16ABDD913, xmp.iid:18C9F4FCFC35E011AD99E6B16ABDD913, xmp.iid:3E32677D0436E011AD99E6B16ABDD913, xmp.iid:EE3853A10F39E011B5D28BF2D5C9CF31, xmp.iid:4EEB9B391139E011B5D28BF2D5C9CF31, xmp.iid:7BF16B701339E011B5D28BF2D5C9CF31, xmp.iid:367D22701439E011B5D28BF2D5C9CF31, xmp.iid:3A6C46F11539E011B5D28BF2D5C9CF31, xmp.iid:3EF1A8181739E011B5D28BF2D5C9CF31, xmp.iid:5CCEF3341839E011B5D28BF2D5C9CF31, xmp.iid:730F6B293F39E011BA798E446735E164, xmp.iid:5EE8857B3F39E011BA798E446735E164, xmp.iid:25F9AD364D39E011BA798E446735E164, xmp.iid:8F66177A4D39E011BA798E446735E164, xmp.iid:FFC5F0890B3AE01185DDA66A0E567151, xmp.iid:EEB572D50C3AE01185DDA66A0E567151, xmp.iid:830F4DEC0C3AE01185DDA66A0E567151, xmp.iid:BB09AEFC103AE011AAF5BE2EAA115897, xmp.iid:5CDA74D89E3AE0118C22942D684B6696, xmp.iid:E86DADD19F3AE0118C22942D684B6696, xmp.iid:B45B1067A63AE01191FAE9EC6380756D, xmp.iid:4D022906A73AE01191FAE9EC6380756D, xmp.iid:2D0A17E1A73AE011943DCE59ABE731E1, xmp.iid:2E0A17E1A73AE011943DCE59ABE731E1, xmp.iid:B7A76233A83AE01186A7F4CA51AE3464, xmp.iid:61792174072068118C14A2F881D1572E, xmp.iid:DE30D081082068118C14A2F881D1572E, xmp.iid:1B1BF6280D2068118C14A2F881D1572E, xmp.iid:7C3CAD150F2068118C14A2F881D1572E, xmp.iid:2027559C0F2068118C14A2F881D1572E, xmp.iid:9F71BEE0102068118C14A2F881D1572E, xmp.iid:BBBD861F152068118C14A2F881D1572E, xmp.iid:006A8FBE162068118C14A2F881D1572E, xmp.iid:12CF2218172068118C14A2F881D1572E, xmp.iid:12C5F56C172068118C14A2F881D1572E, xmp.iid:4DF5F6B0262068118C14A2F881D1572E, xmp.iid:92069B4F2A2068118C14A2F881D1572E, xmp.iid:EE71EEF81A2068118C14821FD48F42A1, xmp.iid:14C3BD251B2068118C14821FD48F42A1, xmp.iid:0D9BD2591B2068118C14821FD48F42A1, xmp.iid:AE749CE31B2068118C14821FD48F42A1, xmp.iid:0F66CAAE1C2068118C14821FD48F42A1, xmp.iid:100EFC421D2068118C14821FD48F42A1, xmp.iid:E5222674072068118C14ABAA97ACE043, xmp.iid:D69FBDB5072068118C14ABAA97ACE043, xmp.iid:D55F8561082068118C14ABAA97ACE043, xmp.iid:EAAEEFA13F2068118C14B8F9439AED2A, xmp.iid:E5560599402068118C14B8F9439AED2A, xmp.iid:0077820E412068118C14B8F9439AED2A, xmp.iid:66E64FC0412068118C14B8F9439AED2A, xmp.iid:0FFA38A8462068118C14B8F9439AED2A, xmp.iid:B05A46CF482068118C14B8F9439AED2A, xmp.iid:3129370C4A2068118C14B8F9439AED2A, xmp.iid:2BC02E74072068118083807F2AE95E83, xmp.iid:88EA380B082068118083807F2AE95E83, xmp.iid:99F00CD0082068118083807F2AE95E83, xmp.iid:163A93590B2068118083807F2AE95E83, xmp.iid:61DE2BE10B2068118083807F2AE95E83, xmp.iid:C44051420C2068118083807F2AE95E83, xmp.iid:D55D948D1F2068118C14EAE433F45401 History When : 2011:01:05 16:29:30-06:00, 2011:01:05 16:29:30-06:00, 2011:01:05 17:12:22-06:00, 2011:01:05 17:14:09-06:00, 2011:01:05 17:14:09-06:00, 2011:01:06 07:05:27-06:00, 2011:01:06 10:58:08-06:00, 2011:01:06 11:03:07-06:00, 2011:01:06 11:15:16-06:00, 2011:01:06 11:23:58-06:00, 2011:01:06 11:59:39-06:00, 2011:01:06 12:07:44-06:00, 2011:01:06 12:30:33-06:00, 2011:01:06 12:42-06:00, 2011:01:06 13:04:21-06:00, 2011:01:06 13:31:41-06:00, 2011:01:06 13:51:57-06:00, 2011:01:06 13:54:41-06:00, 2011:01:06 14:27:08-06:00, 2011:01:07 09:09:31-06:00, 2011:01:07 10:03:05-06:00, 2011:01:07 10:05:54-06:00, 2011:01:07 10:15:13-06:00, 2011:01:07 13:30:55-06:00, 2011:01:07 15:30:45-06:00, 2011:01:07 15:53:52-06:00, 2011:01:10 11:20:33-06:00, 2011:01:10 11:29:29-06:00, 2011:01:10 11:37:24-06:00, 2011:01:10 11:40:30-06:00, 2011:01:10 11:53:29-06:00, 2011:01:10 11:57:01-06:00, 2011:01:10 12:02-06:00, 2011:01:10 12:04:47-06:00, 2011:01:10 12:08:53-06:00, 2011:01:10 12:17:55-06:00, 2011:01:10 12:22:18-06:00, 2011:01:10 12:25:49-06:00, 2011:01:10 12:40:08-06:00, 2011:01:10 12:45:26-06:00, 2011:01:10 12:54:25-06:00, 2011:01:10 12:56:46-06:00, 2011:01:10 12:58:18-06:00, 2011:01:10 15:23:14-06:00, 2011:01:10 15:30:45-06:00, 2011:01:10 16:31:17-06:00, 2011:02:04 15:40:52-06:00, 2011:02:04 15:45:38-06:00, 2011:02:04 16:02:21-06:00, 2011:02:04 16:04:27-06:00, 2011:02:07 08:48:49-06:00, 2011:02:07 09:07:22-06:00, 2011:02:07 09:21:15-06:00, 2011:02:07 09:47:15-06:00, 2011:02:07 09:59-06:00, 2011:02:07 10:20:29-06:00, 2011:02:11 09:53:30-06:00, 2011:02:11 09:53:30-06:00, 2011:02:11 09:56:45-06:00, 2011:02:11 10:03:38-06:00, 2011:02:11 10:14:44-06:00, 2011:02:11 10:35:28-06:00, 2011:02:11 10:35:51-06:00, 2011:02:11 10:35:51-06:00, 2011:02:11 11:29:33-06:00, 2011:02:15 08:26:51-06:00, 2011:02:15 08:38:16-06:00, 2011:02:15 08:54:07-06:00, 2011:02:15 09:01:16-06:00, 2011:02:15 09:12:02-06:00, 2011:02:15 09:20:18-06:00, 2011:02:15 09:28:15-06:00, 2011:02:15 14:07:06-06:00, 2011:02:15 14:09:23-06:00, 2011:02:15 15:47:41-06:00, 2011:02:15 15:49:34-06:00, 2011:02:16 14:30:05-06:00, 2011:02:16 14:39:21-06:00, 2011:02:16 14:39:59-06:00, 2011:02:16 15:09:05-06:00, 2011:02:17 08:04:33-06:00, 2011:02:17 08:11:31-06:00, 2011:02:17 08:58:38-06:00, 2011:02:17 09:03:51-06:00, 2011:02:17 09:09:13-06:00, 2011:02:17 09:09:13-06:00, 2011:02:17 09:11:31-06:00, 2011:04:21 09:56:33-07:00, 2011:04:21 10:04:05-07:00, 2011:04:21 10:37:24-07:00, 2011:04:21 10:51:10-07:00, 2011:04:21 10:54:56-07:00, 2011:04:21 11:04-07:00, 2011:04:21 11:34:24-07:00, 2011:04:21 11:46-07:00, 2011:04:21 11:48:30-07:00, 2011:04:21 11:50:53-07:00, 2011:04:21 13:40:09-07:00, 2011:04:21 14:06:04-07:00, 2011:04:26 09:54:42-07:00, 2011:04:26 09:55:57-07:00, 2011:04:26 09:57:25-07:00, 2011:04:26 10:01:16-07:00, 2011:04:26 10:06:57-07:00, 2011:04:26 10:11:05-07:00, 2011:04:26 11:19:35-07:00, 2011:04:26 11:21:25-07:00, 2011:04:26 11:26:13-07:00, 2011:04:29 16:55:24-04:00, 2011:04:29 17:02:19-04:00, 2011:04:29 17:05:36-04:00, 2011:04:29 17:10:34-04:00, 2011:04:29 17:45:42-04:00, 2011:04:29 18:01:06-04:00, 2011:04:29 18:09:58-04:00, 2011:05:05 15:36:14-05:00, 2011:05:05 15:40:27-05:00, 2011:05:05 15:45:58-05:00, 2011:05:05 16:04:07-05:00, 2011:05:05 16:07:55-05:00, 2011:05:05 16:10:38-05:00, 2011:05:06 10:57:26-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Format : application/pdf Title : 69-2485EFS-03 - TH8320ZW1000 Creator : Honeywell ECC Technical Communications Startup Profile : Print Doc Change Count : 4249 Authors Position : Operating Manual Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 72EXIF Metadata provided by EXIF.tools