Ademco TH8732WF01 TH8732WF User Manual

Honeywell International Inc TH8732WF

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

User Manual

Lyric™ ThermostatJob Name Engineer Mechanical Contractor Contractor’s P.O. No. Representative Notes Model(s)                       Qty.TH8732WF5018            TH8732WF5034            Approval Service Tag No. SUBMITTAL SHEETAPPLICATIONThe Lyric Thermostat is a Wi-Fi enabled comfort system designed to be easy to use as well as maximizes home comfort.  Lyric provides control of single stage and multi stage conventional and heat pump heating and cooling systems.  The thermostat controls up to 2 heat / 2 cool conventional systems and up to 3 heat / 2 cool heat pump systems.   The thermostat also controls humidication, dehumidication or ventilation through the Lyric App.•  Automatically maintains comfort by considering temperature, humidity and weather•  Control from anywhere by smartphone or tablet •  No complex menus. One-touch buttons save you time•  Smart alerts remind you of lter changes and warn you of extreme indoor conditions•  Weather information to help plan your daySPECIFICATIONSIncludes:Lyric Wi-Fi thermostatLyric App for Android or iOSAAA Lithium battery, wall plate, wall cover and mounting screwsRequirements:802.11 b/g/n home wireless routerAndroid or iOS smartphone, tablet or deviceModels:TH8732WF5018TH8732WF5034Terminal Designations:U1B, U1A, C, L, G, K, Y, Y2, W (O/B), W2 (Aux/E), R, RcElectrical Ratings: Terminal Voltage (50/60 Hz)Max. Current RatingW - O/B (heating) 18 to 30 VAC 1.00AW2 - Aux/E (heating) 18 to 30 VAC 0.60AY (cooling) 18 to 30 VAC 1.00AY2 (cooling) 18 to 30 VAC 0.60AK18 to 30 VAC 1.00AG (fan) 18 to 30 VAC 0.50AL (output) 18 to 30 VAC 1.00AU1B, U1A 18 to 30 VAC 0.10 APower Consumption:Full brightness = 3.0 VAWi-Fi Communication: 2.4GHz rangeTemperature Setting Range:Heating: 40 to 90 °F (4.5 to 32 °C)Cooling: 50 to 99 °F (10 to 37 °C)Temperature Sensor Accuracy: ± 1.5 °F at 70 °F (0.75 °C at 21.0 °C)Humidication Setting Range: 10% to 60% RHDehumidication Setting Range: 40% to 80% RHHumidity Display Range: 0% to 99%Humidity Sensor Accuracy: ± 5% RH from 30% to 50% RH at 75 °F (24 °C)Cool Indication: Displays the snowake icon   in cooling mode.Heat Indication: Displays the sun icon   in heating mode.Mounting Means:Thermostat: The thermostat is mounted via a wall plate. The wall plate is mounted directly on the wall in the living space, using mounting screws provided. The thermostat is then snapped directly onto the wall plate. Trim Ring (Optional): The wall plate is rst attached to the trim ring. The trim ring and wall plate are then mounted directly on the wall in the living space, using mounting screws and anchors provided.33-00031EFS-01
Automation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422customer.honeywell.com® U.S. Registered Trademark© 2014 Honeywell International Inc.33-00031EFS—01     M.S.   04-14Printed in United StatesProduct Part Number Operating Ambient Temperature Operating Relative HumidityShipping Temperature Physical Dimensions in mm (Height x Width x Depth) Color(s)ThermostatTH8732WF5018 32 to 120 °F(0 to 48.9 °C) 5% to 90%Non-Condensing-20 to 120 °F(-28.9 to 48.9 °C) 96.5 x 96.5 x 22.49 WhiteTH8732WF5034 32 to 120 °F(0 to 48.9 °C) 5% to 95%Non-Condensing-20 to 120 °F(-28.9 to 48.9 °C) 96.5 x 96.5 x 22.49 WhiteREGULATOR INFORMATIONFCC Compliance Statement (Part 15.19) (USA only)This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:1.  This device may not cause harmful interference, and2.  This device must accept any interference received, including interference that may cause undesired operation.FCC Warning (Part 15.21) (USA only)Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.FCC Interference Statement (Part 15.105 (b))  (USA only)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.ThermostatsTo comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.Section 7.1.2 of RSS-GENUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Section 7.1.3 of RSS-GENOperation is subject to the following two conditions:1.  This device may not cause interference, and2.  This device must accept any interference, including interference that may cause undesired operation of the device.
Download:
Mirror Download [FCC.gov]
Document ID2256066
Application ID98gDx2tYMHwPlI2b6ENvIA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.28kB (128546 bits)
Date Submitted2014-04-30 00:00:00
Date Available2014-06-10 00:00:00
Creation Date2014-04-29 15:37:28
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2014-04-29 15:59:37
Document Title33-00031EFS—01 - Prestige IAQ and Prestige 2.0 Thermostats
Document CreatorAdobe InDesign CC (Windows)
Document Author: Honeywell ECC Technical Communications
FCC ID Filing: HS9-TH8732WF01

Navigation menu