Advanced Radiotech ARCFLEXECO Industrial radio remote control systems User Manual

Advanced Radiotech Corporation Industrial radio remote control systems

User manual

Download: Advanced Radiotech ARCFLEXECO Industrial radio remote control systems User Manual
Mirror Download [FCC.gov]Advanced Radiotech ARCFLEXECO Industrial radio remote control systems User Manual
Document ID2686111
Application IDSpoOAwc5+eOt3DjnvkCspQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize149.26kB (1865705 bits)
Date Submitted2015-07-21 00:00:00
Date Available2016-01-17 00:00:00
Creation Date2015-06-03 11:19:56
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2015-06-03 11:19:56
Document TitleMicrosoft Word - Flex ECO 12 Instruction Manual-20150603
Document CreatorPScript5.dll Version 5.2.2
Document Author: Christo

ECOSeries
Instruction Manual
Service Information
Your New Radio Remote Control System
Thank you for your purchase of ARC Flex ECO radio remote control system. Without a doubt, our
Flex ECO system is the ultimate solution for providing precise, undeterred, and safe control of your
material.
If your product ever needs modification or service, please contact our representative in your country
or at the following location:
World Headquarter:
Advanced Radiotech Corporation
288-1, Hsin Ya Road, Chien Chen District
Kaohsiung, Taiwan
Telephone:
+886 7 812 8112
Fax Number:
+886 7 812 8119
Website:
www.advanced-radiotech.com
E-mails:
info@advanced-radiotech.com
sales@advanced-radiotech.com
All rights reserved. This notice applies to all copyrighted materials included with this product, including,
but not limited to, this manual and software embodied within the product. This manual is intended for
the sole use of the person(s) to whom it was provided, and any unauthorized distribution of the
manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole
or in part by any means whatsoever without the expressed written permission of ARC.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 1 of 36
PRODUCT MANUAL SAFETY INFORMATION
Advanced Radiotech Corporation (ARC) offers a broad range of radio remote control product for
material handling applications. This manual has been prepared by ARC to provide information and
recommendations for the installation, use, operation and service of ARC’s material handling products
and systems (ARC Products). Anyone who uses, operates, maintains, services, installs or owns ARC
Products should know, understand, and follow the instructions and safety recommendations in this
manual for ARC Products.
The recommendations in this manual do not take precedence over any of the following requirements
relating to cranes, hoists lifting devices or other material handling equipment which use or include
ARC Products:

Instructions, manuals, and safety warnings of the manufacturers of the equipment where the
radio system is used.

Plant safety rules and procedures of the employers and the owners of facilities where the
ARC Products are being used.

Safety standards and practices for the industries in which ARC Products are used.
This manual does not include or address the specific instructions and safety warnings of these
manufacturers or any of the other requirements listed above. It is the responsibility of the owners,
users and operators of the ARC Products to know, understand and follow all of these requirements. It
is the responsibility of the employer to make its employees aware of all of the above listed
requirements and to make certain that all operators are properly trained. No one should use ARC
Products prior to becoming familiar with and being trained in these requirements and the
instructions and safety recommendations in this manual.
WARRANTY INFORMATION
For information on ARC’s product warranties, please contact ARC representative nearest to you or
visit www.advanced-radiotech.com.
FCC WARNINGS and CAUTIONS
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
RADIO FREQUENCY INTERFERENCE STATEMENT
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received, including interference that may cause undesired
operation.
FCC Caution: Any change or modification not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 2 of 36
Table of Contents
1.
2.
3.
4.
5.
6.
7.
8.
Introduction
Radio Controlled Safety
General System Information
3.1 Transmitter
3.1.1
External Illustration
3.1.2
Internal Illustration
3.2 Receiver
3.2.1
External Illustration
3.2.2
Internal Illustration
Function Settings
4.1 Transmitter
4.1.1
Enter Function Setting Mode
4.1.2
Channel Settings
4.1.3
Remote Pairing
4.1.4
Start Function Settings
4.1.5
Inactivity Timer Settings
4.1.6
Infrared Programming
4.1.7
Pushbutton Function Settings
4.2 Receiver
4.2.1
Channel Settings
4.2.2
Output Relay Configurations
4.2.3
Dipswitch Settings
4.2.4
Jumper Settings
4.2.5
Voltage Settings
4.2.6
Lights Indicator and Buzzer Installation
4.2.7
System Channels Table
Receiver Installation
5.1 Output Relay Contact Diagrams
5.2 Pre-installation Precautions
5.3 Step-By-Step Installation
Operating Procedures
6.1 General Operation
6.2 A/B Pushbutton Select Operation
6.3 A/B Rotary Select Operation
6.4 Pitch & Catch Operation
6.5 Changing Batteries
6.6 System Status Light Indications
General Specifications
EU Declaration of Conformity
Page
10
11
12
13
13
14
15
15
15
16
18
18
22
24
25
25
26
27
28
28
31
32
32
32
32
33
35
36
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 3 of 36
1. Introduction
The Flex ECO radio remote control systems are designed for control of industrial
equipment and machinery such as overhead traveling cranes, jib cranes, gantry cranes, tower
cranes, electric hoists, winches, monorails, conveyor belts, mining equipment, and other
material handling equipment where wireless control is preferred.
Each Flex ECO system consists of a transmitter handset and a receiver unit. Other
standard-equipped accessories include transmitter lanyard, belt clip, clear vinyl pouch,
pushbutton labels, output cable, and instruction manual.
List of notable features include:
62 user-programmable channels – advanced synthesized RF controls with 62 built-in
programmable channels.
Wireless remote pairing function – system pairing can be done easily and wirelessly.
Over one million unique ID codes (20bit) – each and every Flex ECO system has its own
unique ID codes and serial number, never repeats.
Advanced controls – the Flex ECO system utilizes advanced microprocessor controls with
32bit CRC and Hamming Code, which provide ultra fast, safe, precise, and error-free
encoding and decoding.
Dual-way communication – transmitter and receiver communicates with one another for safe,
precise and uninterrupted operation.
Reliable pushbuttons – the pushbuttons are rated for more than five million press cycles.
Low power consumption – requires only two “AA” Alkaline batteries for more than 150
hours of operation between replacements.
Ultra-durable nylon and fiberglass composite enclosures – highly resistance to breakage
and deformation even in the most abusive environments. The receiver enclosures and
output cables are UL94-V0 rated.
Fully sealed enclosures – the transmitter and receiver enclosures are IP66 rated.
Full compliance – all systems are fully complied with the FCC Part-15 Rules and European
Safety Standards.
Other optional accessories and features – transmitter magnet mount, transmitter waist belt,
2 and 3-position rotary select switch, transmitter rubber guards, miniature indicator lights
and buzzer, dual-crane tandem function, multi-crane random access function, and many
others.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 4 of 36
2. Radio Controlled Safety
WARNINGS and CAUTIONS
Throughout this document WARNING and CAUTION statements have been deliberately placed to highlight items
critical to the protection of personnel and equipment.
WARNING – A warning highlights an essential operating or maintenance procedure, practice, etc. which if
not strictly observed, could result in injury or death of personnel, or long term physical hazards.
Warnings are highlighted as shown below:
WARNING
CAUTION – A caution highlights an essential operating or maintenance procedure, practice, etc. which if
not strictly observed, could result in damage to, or destruction of equipment, or loss of functional
effectiveness. Cautions are highlighted as shown below:
CAUTION
WARNINGS and CAUTIONS SHOULD NEVER BE DISREGARDED.
The safety rules in this section are not intended to replace any rules or regulations of any applicable local, state,
or federal governing organizations. Always follow your local lockout and tagout procedure when maintaining any
radio equipment. The following information is intended to be used in conjunction with other rules or regulations
already in existence. It is important to read all of the safety information contained in this section before installing
or operating the Radio Control System.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 5 of 36
2.1 CRITICAL INSTALLATION CONSIDERATIONS
WARNING
PRIOR TO INSTALLATION AND OPERATION OF THIS EQUIPMENT, READ AND DEVELOP AN
UNDERSTANDING OF THE CONTENTS OF THIS MANUAL AND THE OPERATION MANUAL OF THE
EQUIPMENT OR DEVICE TO WHICH THIS EQUIPMENT WILL BE INTERFACED. FAILURE TO FOLLOW
THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
ALL EQUIPMENT MUST HAVE A MAINLINE CONTACTOR INSTALLED AND ALL TRACKED CRANES,
HOISTS, LIFTING DEVICES AND SIMILAR EQUIPMENT MUST HAVE A BRAKE INSTALLED. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
AN AUDIBLE AND/OR VISUAL WARNING MEANS MUST BE PROVIDED ON ALL REMOTE CONTROLLED
EQUIPMENT AS REQUIRED BY CODE, REGULATION, OR INDUSTRY STANDARD. THESE AUDIBLE
AND/OR VISUAL WARNING DEVICES MUST MEET ALL GOVERNMENTAL REQUIREMENTS. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
FOLLOW YOUR LOCAL LOCKOUT TAGOUT PROCEDURE BEFORE MAINTAINING ANY REMOTE
CONTROLLED EQUIPMENT. ALWAYS REMOVE ALL ELECTRICAL POWER FROM THE CRANE, HOIST,
LIFTING DEVICE OR SIMILAR EQUIPMENT BEFORE ATTEMPTING ANY INSTALLATION PROCEDURES.
DE-ENERGIZE AND TAGOUT ALL SOURCES OF ELECTRICAL POWER BEFORE TOUCH-TESTING ANY
EQUIPMENT. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.
THE DIRECT OUTPUTS OF THIS PRODUCT ARE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO
STATE SAFETY CRITICAL MAINTAINED FUNCTIONS, I.E., MAGNETS, VACUUM LIFTS, PUMPS,
EMERGENCY EQUIPMENT, ETC. A MECHANICALLY LOCKING INTERMEDIATE RELAY SYSTEM WITH
SEPARATE POWER CONSIDERATIONS MUST BE PROVIDED. FAILURE TO FOLLOW THIS WARNING
COULD RESULT IN SERIOUS INJURY OR DEATH OR DAMAGE TO EQUIPMENT.
2.2 GENERAL
Radio controlled material handling equipment operates in several directions. Cranes, hoists, lifting devices and
other material handling equipment can be large, and operate at high speeds. Quite frequently, the equipment is
operated in areas where people are working in close proximity to the material handling equipment. The operator
must exercise extreme caution at all times. Workers must constantly be alert to avoid accidents. The following
recommendations have been included to indicate how careful and thoughtful actions may prevent injuries,
damage to equipment, or even save a life.
2.3 PERSONS AUTHORIZED TO OPERATE RADIO
CONTROLLED CRANES
Only properly trained persons designated by management should be permitted to operate radio controlled
equipment.
Radio controlled cranes, hoists, lifting devices and other material handling equipment should not be operated by
any person who cannot read or understand signs, notices and operating instructions that pertain to the equipment.
Radio controlled equipment should not be operated by any person with insufficient eyesight or hearing or by any
person who may be suffering from a disorder or illness, is taking any medication that may cause loss of
equipment control, or is under the influence of alcohol or drugs.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 6 of 36
2.4 SAFETY INFORMATION AND RECOMMENDED TRAINING
FOR RADIO CONTROLLED EQUIPMENT OPERATORS
Anyone being trained to operate radio controlled equipment should possess as a minimum the following
knowledge and skills before using the radio controlled equipment.
The operator should:
 have knowledge of hazards pertaining to equipment operation
 have knowledge of safety rules for radio controlled equipment
 have the ability to judge distance of moving objects
 know how to properly test prior to operation
 be trained in the safe operation of the radio transmitter as it pertains to the crane, hoist, lifting device or
other material handling equipment being operated
 have knowledge of the use of equipment warning lights and alarms
 have knowledge of the proper storage space for a radio control transmitter when not in use
 be trained in transferring a radio control transmitter to another person
 be trained how and when to report unsafe or unusual operating conditions
 test the transmitter emergency stop and all warning devices prior to operation; testing should be done on
each shift, without a load
 be thoroughly trained and knowledgeable in proper and safe operation of the crane, hoist, lifting device, or
other material handling equipment that utilizes the radio control
 know how to keep the operator and other people clear of lifted loads and to avoid “pinch” points
 continuously watch and monitor status of lifted loads
 know and follow cable and hook inspection procedures
 know and follow the local lockout and tagout procedures when servicing radio controlled equipment
 know and follow all applicable operating and maintenance manuals, safety procedures, regulatory
requirements, and industry standards and codes
The operator shall not:

lift or move more than the rated load

operate the material handling equipment if the direction of travel or function engaged does not agree
with what is indicated on the controller

use the crane, hoist or lifting device to lift, support or transport people

lift or carry any loads over people

operate the crane, hoist or lifting device unless all persons, including the operator, are and remain clear
of the supported load and any potential pinch points

operate a crane, hoist or lifting device when the device is not centered over the load

operate a crane, hoist or lifting device if the chain or wire rope is not seated properly in the sprockets,
drum or sheave

operate any damaged or malfunctioning crane, hoist, lifting device or other material handling equipment
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 7 of 36

change any settings or controls without authorization and proper training

remove or obscure any warning or safety labels or tags

leave any load unattended while lifted

leave power on the radio controlled equipment when the equipment is not in operation

operate any material handling equipment using a damaged controller because the unit may be unsafe

operate manual motions with other than manual power

operate radio controlled equipment when low battery indicator is on
WARNING
THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER. IF ANY PRODUCT
PERFORMANCE OR SAFETY CONCERNS ARE OBSERVED, THE EQUIPMENT SHOULD IMMEDIATELY BE
TAKEN OUT OF SERVICE AND BE REPORTED TO THE SUPERVISOR. DAMAGED AND INOPERABLE
RADIO CONTROLLER EQUIPMENT SHOULD BE RETURNED TO MAGNETEK FOR EVALUATION AND
REPAIR. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.
2.5 TRANSMITTER UNIT
Transmitter switches should never be mechanically blocked ON or OFF. When not in use, the operator should
turn the transmitter OFF. A secure storage space should be provided for the transmitter unit, and the transmitter
unit should always be placed there when not in use. This precaution will help prevent unauthorized people from
operating the material handling equipment.
Spare transmitters should be stored in a secure storage space and only removed from the storage space after the
current transmitter in use has been turned OFF, taken out of the service area and secured.
2.6 PRE-OPERATION TEST
At the start of each work shift, or when a new operator takes control of the crane, operators should do, as
a minimum, the following steps before making lifts with any crane or hoist:
Test all warning devices.
Test all direction and speed controls.
Test the transmitter emergency stop.
2.7 BATTERIES
WARNING
KNOW AND FOLLOW PROPER BATTERY HANDLING, CHARGING AND DISPOSAL PROCEDURES.
IMPROPER BATTERY PROCEDURES CAN CAUSE BATTERIES TO EXPLODE OR DO OTHER SERIOUS
DAMAGE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 8 of 36
3. General System Information
3.1 Transmitter
3.1.1 External Illustration
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
STOP Button
START Button
Status LED Indicator
Pushbutton 1 (PB1)
Pushbutton 2 (PB2)
Pushbutton 3 (PB3)
Pushbutton 4 (PB4)
Pushbutton 5 (PB5)
Pushbutton 6 (PB6)
Pushbutton 7 (PB7)
11.
12.
13.
14.
15.
16.
17.
18.
19.
Pushbutton 8 (PB8)
Pushbutton 9 (PB9)
Pushbutton 10 (PB10)
Pushbutton 11 (PB11)
Pushbutton 12 (PB12)
A/B LED Indicators
Battery Cover Screw
System Information
Lanyard and Waist Belt
Attachment
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 9 of 36
3.1.2 Internal Illustration
1.
2.
3.
4.
RF/Encoder Board
Antenna
START Button
Infrared Sensors
5.
6.
7.
Function Dipswitch
Programming Port
Battery Contacts
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 10 of 36
3.2 Receiver
3.2.1 External Illustration
1.
2.
3.
4.
5.
6.
External Antenna Port (optional)
COM LED Indicator
Status LED Indicator
Power LED Indicator
Output Relay LED Indicators
Infrared Sensor
7.
8.
9.
10.
11.
Remote Pairing Button
System Information
Cord Grip
Mounting Bracket
Mounting Bracket Release
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 11 of 36
3.2.2 Internal Illustration
1.
2.
3.
4.
5.
RF/Decoder Board
INT/EXT Antenna Jumpers
Internal Antenna
Programming Port
Function Dipswitches
6.
7.
8.
9.
10.
Function Jumpers
Channel Dipswitch
AC Line Filter/Relay Board
Power Transformer
Voltage Selector
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 12 of 36
4. Function Settings
4.1 Transmitter
4.1.1 Enter Function Setting Mode
1) Press down the STOP button.
2) Open the battery cover.
3) Set dip position #10 to “1” or ON position.
4) Reset the STOP button (transmitter power on).
5) Entered Function Setting Mode.
6) Status LED displays firmware version.
4.1.2 Channel Settings
1) After entering the Function Setting Mode (refer to section
4.1.1 Enter Function Setting Mode).
2) Press and hold PB3 for up to 1 second to enter the
Channel Setting Mode (Status LED blinks orange).
3) Release PB3 (Status LED displays current channel). A
green blink represents the tens (+10) and a red blink
represents the units (+1). For example, 1 green blink
followed by 5 red blinks is channel 15.
4) Press PB1 to increment the units (+1) and PB2 to
increment the tens (+10). For example, press PB2 two
times and then PB1 four times is channel 24. When finished the transmitter Status
LED will display the newly selected channel.
5) Transfer the newly selected transmitter channel to the receiver by press and hold
PB3 for up to 10 seconds or until the Status LED turns off; the transferring process
is completed. Make sure the receiver power is turned on during the entire process.
Skip step 5 if changing receiver channel is not required or needed.
6) Exit Function Setting Mode by pressing down the STOP button and set the dip
position #10 back to “0” or OFF position.
7) Reset the STOP button and then press the START button to resume operation.
Note : When selecting a new channel make sure each button press do not exceed 3 seconds.
Important Note:
Step 5 illustrated above is strictly required if you are changing the entire system channel (both
transmitter and receiver). If you exit the Channel Setting Mode without pressing PB3 for up to
10 seconds to transfer the newly selected channel to the receiver then the system channel will
no longer match (new transmitter channel vs. old receiver channel). In this case you would
have to change the newly selected transmitter channel back to its previous setting by reentering
the Function Setting Mode and then press and hold PB1 and PB3 at the same time for up to 2
seconds; this will reset the newly selected transmitter channel back to its previous setting. Or
perform section 4.1.3 Receiver-to-Transmitter Pairing process; this will transfer the receiver
channel to the transmitter. Then repeat the channel setting process if you would like to select a
new channel.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 13 of 36
4.1.3 Remote Pairing
A. Transmitter-to-Transmitter Pairing:
1) After entering the Function Setting Mode (refer to
section 4.1.1 Enter Function Setting Mode).
2) Press and hold both PB3 and PB4 for up to 1
second (Status LED blinks orange).
3) Release PB3 and PB4 (Status LED turns off).
4) Entered Remote Pairing Mode.
5) Output data (original transmitter) by press and hold
PB3 (Status LED blinks green).
6) Receive data (new transmitter) by press and hold
PB4 (Status LED blinks green).
7) When the Status LED (receiving data end) turns to constant green while both
pushbuttons are still pressed down the pairing is completed.
8) Exit Function Setting Mode by pressing down the STOP button and set the dip
position #10 back to “0” or OFF position.
9) Reset the STOP button and then press the START button to resume operation.
→
Output data – original transmitter
(press and hold PB3)
Receive data – new transmitter
(press and hold PB4)
B. Receiver-to-Transmitter Pairing:
JP8 Open Method: After entering the Remote Pairing Mode, output receiver data by press
and hold the Pairing button located on the receiver cover and receive data by press and hold
PB4 on the transmitter, both at the same time. When the transmitter Status LED turns to
constant green while both pushbuttons are still pressed down the pairing is completed.
→
Set JP8 to “Open”
→
Output data - receiver
(Press and hold the Pairing button)
Receiving data – transmitter
(Press and hold PB4)
JP8 Short Method (wireless pairing): After entering the Remote Pairing Mode, press PB1 on
the transmitter one time and then press and hold PB3 for up to 6 seconds. The Status LED blinks
green when PB3 is pressed. Release PB3 when Status LED turns off the pairing is completed.
Make sure the pairing process is executed within a distance of 10 meters from one another.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 14 of 36
4.1.4 Start Function Settings
When transmitter goes into sleep mode (MAIN relays deactivated) press the START button or
any pushbutton to wake up the system (MAIN relays reactivated).
1) After entering the Function Setting Mode (refer to
section 4.1.1 Enter Function Setting Mode).
2) Press PB4 for up to 1 second (Status LED orange).
3) Release PB4 (Status LED with 1 or 2 red blinks).
4) Entered Start Function Mode.
5) Press PB1 to toggle between “START” button and
“ANY” pushbutton reactivation.
* START button reactivation → 2 red blinks
* ANY pushbutton reactivation → 1 red blink.
6) Exit Function Setting Mode by pressing down the
STOP button and set the dip position #10 back to “0” or OFF position.
7) Reset the STOP button and then press the START button to resume operation.
Note : When selecting a new setting make sure each button press do not exceed 3 seconds.
4.1.5 Inactivity Timer Settings
Set how long the system enters the sleep mode after
transmitter inactivity (pushbutton not pressed).
1) Press down the STOP button.
2) Open the battery cover.
3) Set dip position #9 to “0” or OFF for 1 minute.
4) Set dip position #9 to “1” or ON for 3 minutes.
5) Please contact ARC representative if your
application requires a different timer value other
than 1 and 3 minutes.
4.1.6 Infrared Programming
Functions not listed in this manual can be programmed via
the infrared programmer unit, such as the system serial
number, system channel, transmitter output power,
Function output relay settings, etc… Please contact ARC
representative in your country for more details.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 15 of 36
4.1.7 Pushbutton Function Settings
4.1.7.1 Toggled Pushbutton with LED Indication – Standard Right/Left
Pushbutton Configuration
Set pushbutton toggled function (latching output relay) by configuring the 10-position
function dipswitch located inside the battery compartment. The “LED A” and “LED B”
shown inside the shaded boxes illustrates which LED on the transmitter will light up
when the designated pushbutton is pressed (PB11 & PB12).
DIP
PB9
PB10
PB11
PB12
0000011100
Normal
Normal
LED A
Normal
0000100000
Normal
Normal
Normal
LED B
0000100100
Normal
Normal
LED A
LED B
* PB9…PB12 → Pushbutton number.
* Normal → Normal momentary contact.
* LED A & LED B → Pushbutton toggled function with designated LED indication.
4.1.7.2 A/B Pushbutton Select with LED Indication – Standard Right/
Left Pushbutton Configuration
There are 4 different types of A/B selector sequence available. Choose one that is
most suitable for your application. Refer to section 5.1 output relay connections.
Type-A selector sequence : A → B
Type-B selector sequence : Off → A → B
Type-C selector sequence : A → B → A+B
Type-D selector sequence : Off → A → B → A+B
DIP
PB9
PB10
PB11
PB12
0001101000
Normal
Normal
A/1&2
Normal
0001101100
Normal
Normal
B/1&2
Normal
0001110000
Normal
Normal
C/1&2
Normal
0001110100
Normal
Normal
D/1&2
Normal
0001111000
Normal
Normal
Normal
A/1&2
0001111100
Normal
Normal
Normal
B/1&2
0010000000
Normal
Normal
Normal
C/1&2
0010000100
Normal
Normal
Normal
D/1&2
* PB9…PB12 → Pushbutton number.
* Normal → Normal momentary contact.
* A/1&2 ~ D/1&2 → A/B pushbutton select function with designated LED indication.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 16 of 36
4.1.7.3 Toggled Pushbutton with LED Indication – Inline Top/Bottom
Pushbutton Configuration
Set pushbutton toggled function (latching output relay) by configuring the 10-position
function dipswitch located inside the battery compartment. The “LED A” and “LED B”
shown inside the shaded box illustrates which LED on the transmitter will light up
when the designated pushbutton is pressed (PB11 & PB12). Refer to section 4.2.4
JP4/JP5 inline jumper settings.
DIP
PB9
PB10
PB11
PB12
1001101000
Normal
Normal
LED A
Normal
0000100000
Normal
Normal
Normal
LED B
1001101100
Normal
Normal
LED A
LED B
* PB9…PB12 → Pushbutton number.
* Normal → Normal momentary contact.
* LED A & LED B → Pushbutton toggled function with designated LED indication.
4.1.7.4 A/B Pushbutton Select with LED Indication – Inline Top/Bottom
Pushbutton Configuration
There are 4 different types of A/B selector sequence available. Choose one that is
most suitable for your application. Refer to section 4.2.4 JP4/JP5 inline jumper
settings and section 5.1 output relay connections.
Type-A selector sequence : A → B
Type-B selector sequence : Off → A → B
Type-C selector sequence : A → B → A+B
Type-D selector sequence : Off → A → B → A+B
DIP
PB9
PB10
PB11
PB12
1010010000
Normal
Normal
A/1&2
Normal
1010010100
Normal
Normal
B/1&2
Normal
1010011000
Normal
Normal
C/1&2
Normal
1010011100
Normal
Normal
D/1&2
Normal
0001111000
Normal
Normal
Normal
A/1&2
0001111100
Normal
Normal
Normal
B/1&2
0010000000
Normal
Normal
Normal
C/1&2
0010000100
Normal
Normal
Normal
D/1&2
* PB9…PB12 → Pushbutton number.
* Normal → Normal momentary contact.
* A/1&2 ~ D/1&2 → A/B pushbutton select function with designated LED indication.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 17 of 36
4.2 Receiver
4.2.1 Channel Settings
Set the receiver channel by configuring the channel
dipswitch located on the RF/decoder board, only the first 6
dip positions are used for channel programming. The
system channels table on section 4.2.7 illustrates which
dipswitch setting corresponds to which channel. Once the
receiver channel is altered do make sure to change the
transmitter channel as well. The channel on both transmitter
and receiver must be identical in order for the system to
work (refer to section 4.1.2 Transmitter Channel Settings).
Example:
Top position → “1”
Bottom position → “0”
1 2 3 4 5 6 7 8
The above dipswitch setting “1 0 0 1 0 0” corresponds to “channel 36” in the system channels table
on section 4.2.7.
4.2.2 Output Relay Configurations
4.2.2.1 Output Relay Types
1.
2 output relays per motion – single speed only
Output relays with Forward (F) and Reverse (R) speed.
2.
3 output relays per motion – shared 2nd speed output relay
Output relays with Forward 1st speed (F1), Reverse 1st speed (R1) and
Forward/Reverse 2nd speed (F/R2). Forward and Reverse 2nd speed (F/R2)
shared the same output relay.
3.
4 output relays per motion – separate 1st and 2nd speed output relays
Output relays with Forward 1st speed (F1), Reverse 1st speed (R1), Forward
2nd speed (F2) and Reverse 2nd speed (R2). Forward and Reverse 2nd speed
with separate output relays.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 18 of 36
4.2.2.2 Output Relay Actions at 2nd Speed (Flex ECO 12X only)
1.
3 output relays configuration with Closed/Closed contact at 2nd speed
At 2nd speed, both 1st speed (F1 or R1) and 2nd speed (F/R2) output
relays are closed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1st speed pushbutton pressed
Forward 2nd speed pushbutton pressed
↓
↓
F1
R1
2.
F/R2
F1
R1
F/R2
4 output relays configuration with Opened/Closed contact at 2nd speed
At 2nd speed, only the 2nd speed (F2 or R2) output relay is closed. Refer to
section 4.2.3.1 on how to set to this function.
Forward 1st speed pushbutton pressed
Forward 2nd speed pushbutton pressed
↓
↓
F1
R1
3.
F2
R2
F1
R1
F2
R2
4 output relays configuration with Closed/Closed contact at 2nd speed
At 2nd speed, both 1st speed (F1 or R1) and 2nd speed (F2 or R2) output relays
are closed. Refer to section 4.2.3.1 on how to set to this function.
Forward 1st speed pushbutton pressed
Forward 2nd speed pushbutton pressed
↓
↓
F1
R1
F2
R2
F1
R1
F2
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 19 of 36
R2
4.2.2.3 START + AUX Function
After initiating the START function at transmitter startup the
same START button becomes an auxiliary function with
momentary contact connected through K25 Function output
relay. There are other types of auxiliary functions made
available for K25 and K26 Function output relays. Please
contact ARC representative if your application requires other
types of auxiliary function connected to these Function output
relays.
4.2.2.4 ON/OFF Pushbutton Function
The user can set any of the two adjacent pushbuttons on the
transmitter to behave like a mechanical ON & OFF rocker or
toggle switch. ON output relay closes when ON pushbutton
is pressed (OFF output relay opens) and OFF output relay
closes when OFF pushbutton is pressed (ON output relay
opens). Refer to section 4.2.3.1 on how to set to this
function.
4.2.2.5 Magnet ON/OFF Pushbutton Function
The user can set any of the two adjacent pushbuttons on the
transmitter to control industrial magnet left. Activate the
magnet by pressing the Magnet ON pushbutton. Deactivate
the magnet by first press and hold the Magnet ON
pushbutton and then press the Magnet OFF pushbutton.
Pressing the Magnet OFF pushbutton alone is unable to
deactivate the magnet. Refer to section 4.2.3.1 on how to
set to this function.
4.2.2.6 Brake Function (Flex ECO 12X only)
When the transmitter pushbutton is released from 2nd speed up to 1st speed, both 1st
and 2nd speed output relays will open for up to 1 second and then with 1st speed
output relay closed thereafter. Refer to section 4.2.3.1 on how to set to this function.
4.2.2.7 External Warning Function
The user can install an external warning device (rotating lights, horn, etc…) to the
K26 Function output relay (or to K30 Function output relay, refer to section 4.2.6)
located inside the receiver. The user can choose which pushbutton pair (or pairs)
triggers the external warning device when pressed. Refer to section 4.2.3.1 on how
to set to this function.
4.2.2.8 Momentary Contact
When pushbutton is released the corresponding output relay will open or deactivate.
This type of relay action is usually applies to external applications such as horn and
buzzer. Refer to section 4.2.3.2 on how to set to this function.
4.2.2.9 Toggled Contact
When pushbutton is released the corresponding output relay will maintained contact
or closure until next time the user presses the same pushbutton again. This type of
relay action is usually applies to external application such as lights. Refer to section
4.2.3.2 on how to set to this function.
4.2.2.10 Acceleration Function
This function allows the crane or equipment to travel beyond
2nd speed. For example, while the operator press and hold
the “UP” pushbutton at 2nd speed, pressing the ACCEL
pushbutton one time will trigger the 3rd speed, press the ACCEL
pushbutton again will revert back to the 2nd speed. Refer to
section 4.2.3.2 on how to set to this function.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 20 of 36
4.2.2.11 Auxiliary STOP Function
The auxiliary STOP function acts as a 2nd emergency stop
button. When pressed, the receiver MAIN relays are
deactivated (refer to section 4.2.3.2 on how to set to this
function). When set to this function the Start Function on
section 4.1.4 must set to “START” button reactivation.
4.2.2.12 Pitch & Catch Function
This function allows two operators controlling a crane, hoist or equipment from
opposite ends of the facility. When set to “Pitch & Catch” make sure the 2nd
transmitter is set to the next upper channel (channel X+1). For example, if the
original (1st) transmitter and receiver are set to channel 01 then the newly added 2nd
transmitter must set to channel 02 (all with same serial number). Furthermore, the
Channel dipswitch position #7 and #8 on the RF/decoding board in the receiver must
set to “10” for 2-channel scanning (scans channel 01 and 02). Refer to section
4.2.2.13 and 4.2.3.2 on how to set to this function.
4.2.2.13 Receiver Channel Scanning Function
(1)
→ “00” manufacture preset (channel X)
1 2 3 4 5 6 7 8
(2)
→ “01” scans 2 channels (channel X and channel X+1)
1 2 3 4 5 6 7 8
(3)
→ “10” scans 3 channels (channel X… channel X+2)
1 2 3 4 5 6 7 8
(4)
→ “11” scans 4 channels (channel X… channel X+3)
1 2 3 4 5 6 7 8
* Channel X → channel set on the Channel dipswitch
Example: If the first 6 dipswitch positions are set to channel 01 (000001), when set to 2-channel
scanning (type-2 above) the receiver will only scan channel 01 and 02.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 21 of 36
4.2.3 Dipswitch Settings
4.2.3.1 Interlocked Pushbutton Pair
Interlocked means the pushbutton pair
can not be activated at the same time,
as it will cancel each other out.
Interlocked settings are usually applied
to electric motors with forward/reverse
motion and On & Off switches. Each
dipswitch on the RF/decoder board
corresponds to a pushbutton pair.
Dip
Settings
00000000
00000010
00000100
00000110
00001100
Function Descriptions
Single speed
(F2, R2 and F/R2 relays not used)
Closed / Closed relay action at 2nd speed
(separate 2nd speed relay)
Closed / Closed relay action at 2nd speed
(shared 2nd speed relay)
Opened / Closed relay action at 2nd speed
(separate 2nd speed relay)
On (right button) & Off (left button)
# of Relays
Used
On + Start / Off + Start - For added safety, you must first
00010010
press and hold the START button and then press the
On or Off pushbutton to activate the output relay.
00001110
Magnet Left On & Off
00010100
FWD / REV toggled (latching)
00100000
Single speed + External Warning*
00100010
Closed / Closed relay action + External Warning*
00100100
Closed / Closed relay action + External Warning*
00100110
Opened / Closed relay action + External Warning*
01000010
Closed / Closed relay action + Brake
01000100
Closed / Closed relay action + Brake
01000110
Opened/ Closed relay action + Brake
01100010
Closed / Closed relay action + Brake + External Warning*
01100100
Closed / Closed relay action + Brake + External Warning*
01100110
Opened / Closed relay action + Brake + External Warning*
* External warning function requires installing an external warning device such as horn and lights
to K26 Function output relay, or to K30 Function relay using the in-house designed miniature
lights and buzzer illustrated on section 4.2.6.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 22 of 36
4.2.3.2 None-Interlocked Pushbutton Pair
Non-interlocked settings allow the pushbutton pair be used at the same time. Noninterlocked settings are usually applied to crane’s or equipment’s auxiliary functions
such as lights, horn or buzzer. Each dipswitch on the RF/decoder board
corresponds to a pushbutton pair. Only the first 7 dipswitch positions are used
(counting from left to right), the 8th dipswitch position (far right) is not used.
1 2 3 4 5 6 7 8
Dip
Function
Position
Code
#1
Dip Position
#2~#4 (left button)
#5~#7 (right button)
Function Description
000
Normal (momentary) contact
001
Toggled (latching) contact
010
Acceleration (3rd speed)
100
Normal + Start function - For added
safety, you must first press and hold the
START button and then press the
intended pushbutton to activate the
output relay.
110
Pitch & Catch
111
Auxiliary Stop
Example #1: Left button (set to function code A) / right button (set to function code B) → 1 000 001
Example #2: Left button (set to function code C) / right button (set to function code D) → 1 010 100
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 23 of 36
4.2.4 Jumper Settings
Jumper settings are applied to functions such as the Start
function, transmitter standard right/left or inline pushbutton
configurations, firmware version, system testing and remote
pairing function.
Jumper Settings
Function
JP3
(Opened)
Standard A/B selector sequence - Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Inserted)
Reversed logic A/B selector sequence - Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP4
(Opened)
JP5
(Opened)
Standard right/left pushbutton configuration.
JP4
(Inserted)
JP5
(Opened)
Inline top/bottom pushbutton configuration for PB1 to PB8.
JP4
(Opened)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB12.
JP4
(Inserted)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB4.
JP6
(Inserted)
System firmware version.
JP7
(Inserted)
For system testing only, receiver MAIN relays disabled.
JP8
(Blank)
Receiver-to-transmitter remote pairing.
(requiring pressing the PAIRING button on receiver)
JP8
(Inserted)
Receiver-to-transmitter remote pairing.
(do not require pressing the PAIRING button on receiver)
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 24 of 36
4.2.5 Voltage Settings
Prior to installation always check the voltage setting is correct for your application.
Position 1 → 110~120VAC
Position 2 → 220~240VAC
COM
FUSE # 110~120VAC 220~240VAC
F3 ~ F10
5.0A
5.0A
F1 ~ F2
0.5A
0.5A
4.2.6 Lights Indicator and Buzzer Installation
In-house designed miniature lights indicator and buzzer can be easily fitted onto the receiver
enclosure. The lights indicator or buzzer works simultaneously with the receiver MAIN relays
(manufacture preset). When receiver MAIN relays are activated the lights indicator or buzzer
is also activated, and vise versa. Make sure the lights indicator or the buzzer is connected to
the K30 Function output relay CN11 port located on the AC line filter/relay board inside the
receiver. Please contact ARC representative if you would like the lights indicator or the
buzzer work differently than described above.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 25 of 36
4.2.7 System Channels Table
Dipswitch
Channel
Setting
Frequency
Dipswitch
Setting
32
433.825MHZ
100000
000010
33
433.850MHZ
100001
433.100MHZ
000011
34
433.875MHZ
100010
04
433.125MHZ
000100
35
433.900MHZ
100011
05
433.150MHZ
000101
36
433.925MHZ
100100
06
433.175MHZ
000110
37
433.950MHZ
100101
07
433.200MHZ
000111
38
433.975MHZ
100110
08
433.225MHZ
001000
39
434.000MHZ
100111
09
433.250MHZ
001001
40
434.025MHZ
101000
10
433.275MHZ
001010
41
434.050MHZ
101001
11
433.300MHZ
001011
42
434.075MHZ
101010
12
433.325MHZ
001100
43
434.100MHZ
101011
13
433.350MHZ
001101
44
434.125MHZ
101100
14
433.375MHZ
001110
45
434.150MHZ
101101
15
433.400MHZ
001111
46
434.175MHZ
101110
16
433.425MHZ
010000
47
434.200MHZ
101111
17
433.450MHZ
010001
48
434.225MHZ
110000
18
433.475MHZ
010010
49
434.250MHZ
110001
19
433.500MHZ
010011
50
434.275MHZ
110010
20
433.525MHZ
010100
51
434.300MHZ
110011
21
433.550MHZ
010101
52
434.325MHZ
110100
22
433.575MHZ
010110
53
434.350MHZ
110101
23
433.600MHZ
010111
54
434.375MHZ
110110
24
433.625MHZ
011000
55
434.400MHZ
110111
25
433.650MHZ
011001
56
434.425MHZ
111000
26
433.675MHZ
011010
57
434.450MHZ
111001
27
433.700MHZ
011011
58
434.475MHZ
111010
28
433.725MHZ
011100
59
434.500MHZ
111011
29
433.750MHZ
011101
60
434.525MHZ
111100
30
433.775MHZ
011110
61
434.550MHZ
111101
31
433.800MHZ
011111
62
434.575MHZ
111110
Channel
Frequency
01
433.050MHZ
000001
02
433.075MHZ
03
5. Receiver Installation
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 26 of 36
5.1 Output Relay Contact Diagrams
Flex ECO 12S (single speed model)
Flex ECO 12X (dual speed model)
* For 9~36VDC power supply, wire #1 corresponds to the negative charge (-) and wire #3 corresponds
to the positive charge (+), wire #2 is GROUND.
* If PB11 (or PB12) is set to A/B pushbutton select or A/B rotary switch select function, output A connects
to K21 (or K22), output B connects to K23 (or K24). Refer to section 4.1.7.2 on how to set to this
function.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 27 of 36
5.2 Pre-installation Precautions
1. Make sure the transmitter and receiver are with identical serial number and channel.
2. Make sure the receiver is not set to the same channel as any other systems in use in the
surrounding area.
3. Make sure the crane or equipment is working properly prior to installation.
4. Make sure the power source to the receiver is set correctly.
5. Switch off the main power source to the crane or equipment prior to installation.
5.3 Step-By-Step Installation
Mounting Bracket Type 1
Mounting Bracket Type 2
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 28 of 36
1. For best reception the location of the receiver should be visible
to the operator at all time.
2. The location selected should not be exposed to high levels of
electric noise. Mounting the receiver next to an unshielded
variable frequency drive may cause radio interference. Always
locate the receiver as far away from variable frequency drive
and electric motor as possible.
3. Ensure the selected location has adequate space to
accommodate the receiver. If an external antenna is used, to
avoid the possibility of antenna damage always locate the
receiver where the antenna is free from any obstacles.
4. When installing an external antenna make sure the SMA jack
located on the RF/decoder board inside the receiver is
connected and jumper set to “EXT” position.
432 mm
Control
Panel
5. For better reception, make sure the receiver is in an upright position.
6. Drill four holes for mounting bracket type 1 and two holes for mounting bracket type 2
on the control panel, wall or location where the receiver is to be installed.
7. Make sure the screws, bolts or shock absorbers are tightened after installation (not
provided with the system).
Mounting Bracket Type 1
Mounting Bracket Type 2
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 29 of 36
8. Slide down the receiver along the guided track to secure the receiver to the mounting
bracket.
9. Remove the receiver by pressing down the bracket release and pull the receiver
upward until it clears the guided track.
Install
Mounting Bracket Type 1
Mounting Bracket Type 2
Remove
Mounting Bracket Type 1
Mounting Bracket Type 2
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 30 of 36
6. Operating Procedures
6.1 General Operation
a.
Reset the STOP button located on the top left hand
corner of the transmitter by rotating it clockwise or
counter clockwise, the button will pop up. Transmitter is
powered on when the STOP button is elevated.
b.
After turning on the transmitter power, check the Status LED on the transmitter for
any sign of system irregularities (refer to section 6.6.1 Transmitter Status
Indications). If the transmitter is in good working order the Status LED will blink
green for up to 2 seconds at startup (no faults detected).
c.
Press the START button for up to 1 second to activate the
receiver MAIN relays. The same START button becomes an
auxiliary function thereafter (refer to section 4.2.2.3 START +
AUX Function). Then press any pushbutton on the
transmitter to begin operation. Pressing any pushbutton
prior to initiating the START command at startup will result in
no signals transmitted (Status LED blinks orange).
d.
In case of an emergency, press down the STOP button to disconnect the receiver
MAIN relays and as well as the transmitter power. To resume operation, rotate the
STOP button clockwise or counter-clockwise, it will pop up. Then press the START
button for up to 1 second to reconnect the receiver MAIN relays. For safety,
pressing the START button is strictly required every time when the transmitter is
turned on or after every STOP button reset.
e.
After 1 minute or 3 minutes of inactivity (pushbutton not pressed) the receiver MAIN
relays are temporarily disconnected (refer to section 4.1.5 Inactivity Timer Settings).
Press any pushbutton or the START button to resume operation (refer to section
4.1.4 Start Function Settings). The receiver MAIN relays are also temporarily
disconnected when the system encounters strong radio interference, dead spots, low
battery condition, and system out of operating range.
f.
Turn off the transmitter power by pressing down the STOP button, it will disconnect
the transmitter power and the receiver MAIN relays altogether.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 31 of 36
6.2 A/B Pushbutton Select Operation
Press the “A/B” pushbutton repeatedly toggles between output
relay A, B and A+B respectively. There are 4 different types of
Select A/B sequence available (refer to section 4.1.7.2).
Standard – Output relay A activated at A position, output relay
B activated at B position, both output relays activated at A+B
position.
Reversed logic - Output relay A activated at B position,
output relay B activated at A position, both output relays deactivated
at A+B position. Refer to section 4.2.4 JP3 jumper settings.
6.3 A/B Rotary Select Operation
Standard - Rotate to A position activates output relay A, rotate
to B position activates output relay B, rotate to A+B position
activates both output relays.
Reversed logic - Rotate to A position activates output relay B,
rotate to B position activates output relay A, rotate to A+B
position deactivates both output relays. Refer to section 4.2.4
JP3 jumper setting.
6.4 Pitch & Catch Operation
Press the “PITCH” pushbutton for up to 2 seconds to release
control of the receiver. Press the START button for up to 1
second to gain control of the receiver. The 2nd operator is
unable to take control of the receiver unless the 1st operator
presses the “PITCH” pushbutton. Refer to section 4.2.2.12
and section 4.2.3.2 on how to set to this function.
6.5 Changing Batteries
Changing transmitter batteries (“AA”
alkaline battery x 2) by unscrewing the
battery cover located on the backside of
the transmitter. During battery installation
make sure the batteries are installed
correctly, with “+” to “+” charge and “–” to
“–” charge. Also make sure the screw is
tightened after battery installation to avoid
water, moisture, dirt, grease, and other
liquid penetration.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 32 of 36
6.6 System Status Light Indications
6.6.1 Transmitter Status Indications
Type
Display Type
Indication
Constant red
Voltage below 1.9V at initial power on.
Transmitter power and receiver MAIN
relays shuts off.
Voltage below 1.8V during operation.
Transmitter power and receiver MAIN
relays shuts off.
1 red blink followed by a
2-second pause
Voltage below 1.85V during operation.
Change batteries suggested.
2 red blinks followed by a
2-second pause
Defective or jammed pushbutton detected
at initial power on.
No light displayed
When defective pushbutton condition
occurs (2 red blinks, type 3 above), find
out which pushbutton is defective by
pressing all of them one at a time. If the
pushbutton is in good working order when
pressed, the Status LED is off. If the Status
LED maintained 2 red blinks then
the pushbutton is defective.
3 red blinks followed by a
2-second pause
EEPROM error.
4 red blinks followed by a
2-second pause
Transmitter is unable to lock onto the
assigned channel.
Constant green for up to
2 seconds
Transmitter power on with no faults detected.
Blinking green
Transmission in progress.
Blinking orange
Pressing any pushbutton prior to initiating
the START command at power on.
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 33 of 36
6.6.2 Receiver Status Indications
Type
Display Type (Green & Red)
Indication
Fast green blinks
Decoding in process
Slow green blinks
Decoding on standby
Two red blinks
Receiver MAIN relays jammed or defective
Fast red blinks
Incorrect transmitter serial number
Constant red
Receiver low voltage
No light displayed
Decoding processors defective
6.6.3 Receiver Power Indications
Type
Display Type (Red)
Indication
On
Power to receiver
Off
No power to receiver
6.6.4 Receiver COM Indications
Type
Display Type (Red)
Indication
On
Power to relay Board
Off
No power to relay board
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 34 of 36
7. General Specifications
Frequency Range
433 ~ 434 MHz
Number of Channels
62 channels
Channel Spacing
25 KHz
Modulation
Digital Frequency Modulation based
on Manchester Code, 20bit address,
32bit CRC and Hamming Code.
Encoder & Decoder
Microprocessor-controlled
Transmitting Range
>100 Meters (300 feet)
Hamming Distance
>6
Frequency Control
Synthesized PLL
Receiver Type
Frequency Auto Scanning
Receiver Sensitivity
-116dBm
Spurious Emission
-50dB
Antenna Impedance
50 ohms
Responding Time
40 Milliseconds (average)
Transmitting Power
1.0mW
Enclosure Type
NEMA-4X
Enclosure Rating
IP66
Output Contact Rating
250V @ 8 Amps
Transmitter Operating Voltage
DC 3.0V
Receiver Power Consumption
7.0 ~ 22.0VA
Available Receiver Voltages
110~120VAC
220~240VAC
Operating Temperature
-25℃ ~ 50℃
Transmitter Dimension
233mm (L) x 69mm (W) x 35mm (H)
Receiver Dimension
260mm (L) x 204mm (W) x 84mm (H)
Transmitter Weight
245g (8.6oz)
Receiver Weight
1.85kg (4.0lb)
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 35 of 36
EU Declaration of Conformity
(EMC, R&TTE, SAFETY & MACHINERY)
For the following equipment:
Product
Multiple Listee Model No.
Manufacturer’s Name
Manufacturer’s Address
Flex ECO Series Radio Remote Control System
Flex ECO 4S/4X, ECO 8S/8X, ECO 12S/12X
Advanced Radiotech Corporation
1F, 288-1, Hsin Ya Road, Chien Chen District,
Kaohsiung, Taiwan
We herby declare, that all major safety requirements, concerning the CE Mark Directive
2006/42/EC and Low Voltage Directive 2006/95/EC, Electromagnetic Compatibility
Directives 2004/108/EC, R&TTE Directive 1999/5/EC are fulfilled, as laid out in the
guideline set down by the member states of the EEC Commission.
The standards relevant for the evaluation of the electrical safety requirements are
as follow:
EMC
R&TTE
SAFETY
MACHINERY
EN 301 489-1 + EN 301 489-3
EN 300 220-1 V2.3.1 + EN 300 220-2 V2.3.1
EN 60950:2006+A1+A11+A12
EN 60204-32:2008, EN 13557:2003+A1:2008
EN ISO 13849-1:2008 (PL=d), EN 60529 (IP66)
SGS
SGS
SGS
SGS
Test reports issued by:
EMC
R&TTE
SAFETY
MACHINERY
Person responsible for marking this declaration:
Tom Jou / President
Name and signature of authorized person
Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 36 of 36

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Christo
Create Date                     : 2015:06:03 11:19:56+08:00
Modify Date                     : 2015:06:03 11:19:56+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - Flex ECO 12 Instruction Manual-20150603
Creator                         : Christo
Document ID                     : uuid:ba7c1b38-8207-4d43-9b89-d14219dce090
Instance ID                     : uuid:f06dbd08-d6c7-4658-bbde-8bc007c997fb
Page Count                      : 37
EXIF Metadata provided by EXIF.tools