Advantech Co TREK520 Computer User Manual

Advantech Co Ltd Computer

Users Manual

Download: Advantech Co TREK520 Computer User Manual
Mirror Download [FCC.gov]Advantech Co TREK520 Computer User Manual
Document ID2379003
Application IDTwBdwFIYzgm8vaxTeKrLFQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize113.36kB (1416994 bits)
Date Submitted2014-09-05 00:00:00
Date Available2014-09-05 00:00:00
Creation Date2017-10-21 08:52:33
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-21 08:52:33
Document Titleuntitled

User Manual
TREK-520
Computer
Copyright
The documentation and the software included with this product are copyrighted
2010 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd.
reserves the right to make improvements in the products described in this
manual at any time without notice. No part of this manual may be reproduced,
copied, translated or transmitted in any form or by any means without the prior
written permission of Advantech Co., Ltd. Information provided in this manual is
intended to be accurate and reliable. How- ever, Advantech Co., Ltd. assumes
no responsibility for its use, nor for any infringements of the rights of third
parties, which may result from its use.
Acknowledgements
Intel and Atom are trademarks of Intel Corporation. Microsoft Windows and
MS-DOS are registered trademarks of Microsoft Corp. All other product
names or trademarks are properties of their respective owners.
Product Warranty (2 years)
Advantech warrants to you, the original purchaser, that each of its products will
be free from defects in materials and workmanship for two years from the date
of purchase.
This warranty does not apply to any products which have been repaired or
altered by persons other than repair personnel authorized by Advantech, or
which have been subject to misuse, abuse, accident or improper installation.
Advantech assumes no liability under the terms of this warranty as a
consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing,
most of our customers never need to use our repair service. If an Advantech
product is defective, it will be repaired or replaced at no charge during the
warranty period. For out- of-warranty repairs, you will be billed according to the
cost of replacement materials, service time and freight. Please consult your
dealer for more details.
If you think you have a defective product, follow these steps:
1. Collect all the information about the problem encountered. (For example,
CPU speed, Advantech products used, other hardware and software used,
etc.) Note anything abnormal and list any onscreen messages you get
when the problem occurs.
2. Call your dealer and describe the problem. Please have your manual,
product, and any helpful information readily available.
3. If your product is diagnosed as defective, obtain an RMA (return
merchandise authorization) number from your dealer. This allows us to
process your return more quickly.
4. Carefully pack the defective product, a fully-completed Repair and
Replacement Order Card and a photocopy proof of purchase date (such as
your sales receipt) in a shippable container. A product returned without
proof of the purchase date is not eligible for warranty service.
5. Write the RMA number visibly on the outside of the package and ship it
prepaid to your dealer.
TREK-520 User Manual
ii
Declaration of Conformity
This product has passed the CE test for environmental specifications.
Test conditions for passing included the equipment being operated within
an industrial enclosure. In order to protect the product from being
damaged by ESD (Electrostatic Discharge) and EMI leakage, we
strongly recommend the use of CE-compliant industrial enclosure
products.
FCC Class B
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that
may cause undesired operation. “Complies with CANADA RSS-210
FCC Part 15.21 information for user
You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that
may cause undesired operation
Notes and Warnings to the User and Installer:
Caution:
This Installation Guide is intended for use by the professional wireless LAN
system installer.
The device cannot be sold retail, to the general public or by mail order. It must be
sold to dealers or have strict marketing control.
Warning: It is the responsibility of the professional installer to ensure that the
system is used exclusively for fixed, point-to-point
operations.
Warning: When using the device in the United States (or where FCC rules apply),
it is the responsibility of the professional installer
to ensure to control the output power not greater then the application.
Who Should Use this Guide:
Installation of this device should be accomplished only by a qualified wireless LAN
system installer who is: -Knowledgeable of the use, installation and configuration
procedures and associated networking components. -Knowledgeable of each
system component’s equipment User and Installation Guide. -Knowledgeable of
the
installation and configuration procedures for the site’s network infrastructure
system and wiring.
-Knowledgeable of the installation procedures, safety, and code requirements for
the site’s antenna, antenna mast, antenna cabling, and installation. We highly
recommend that the antenna installation be performed by a qualified antenna
installation Professional.
Users should not attempt to make such connections themselves, but should
contact the appropriate electrical inspection authority, or
electrician, as appropriate.
1. This Transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
2. This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20 centimeters between the radiator and your body.
In the users manual of the end product, the end user has to be informed to keep at least
20cm separation with the antenna while this end product is installed and operated. The
end user has to be informed that the FCC radio-frequency exposure guidelines for an
uncontrolled environment can be satisfied. The end user has to also be informed that any
changes or modifications not expressly approved by the manufacturer could void the
user's authority to operate this equipment.
Technical Support and Assistance
1.
2.
Visit the Advantech web site at www.advantech.com/support for the
latest information about the product.
Contact the distributor, sales representative, or Advantech's customer
service center for technical support if you need additional assistance.
Please have the following information ready before you call:
– Product name and serial number
– Description of your peripheral attachments
– Description of your software (operating system, version, application
software, etc.)
– A complete description of the problem
– The exact wording of any error messages
Warnings, Cautions and Notes
Warning!
personal
Warnings indicate conditions, which if not observed, can cause
Injury!
Caution!
Cautions are included to help you avoid damaging hardware or
losing data. e.g.
There is a danger of a new battery exploding if it is incorrectly
installed. Do not attempt to recharge, force open, or heat the battery.
Replace the battery only with the same or equivalent type
recommended by the manufacturer. Discard used batteries according
to the manufacturer's instructions.
Note!
Notes provide optional additional information.
Document Feedback
To assist us in making improvements to this manual, we would welcome
comments and constructive criticism. Send all such in writing to:
support@advantech.com
Packing List
Before setting up, check that the items listed below are included, in good
condition. If any item does not accord with the table, please contact your dealer
immediately.
TREK-520 series Computing Box
Accessories for TREK-520
Warranty card
Power cord: DC power inlet cable
Videio in/CAN cable
“Drivers, Utilities and User Manual" CD-ROM
Safety Instructions
1.
2.
3.
Read these safety instructions carefully.
Keep this User Manual for later reference.
Disconnect this equipment from any AC outlet before cleaning. Use a
damp cloth. Do not use liquid or spray detergents for cleaning.
4. For plug-in equipment, the power outlet socket must be located near the
equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installation. Dropping it or
letting it fall may cause damage.
7. The openings on the enclosure are for air convection. Protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before
connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not place
anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the power
source to avoid damage by transient overvoltage.
12. Never pour any liquid into an opening. This may cause fire or electrical
shock.
13. Never open the equipment. For safety reasons, the equipment
should be opened only by qualified service personnel.
14. If one of the following situations arises, get the equipment checked by
service personnel:
15. The power cord or plug is damaged.
16. Liquid has penetrated into the equipment.
17. The equipment has been exposed to moisture.
18. The equipment does not work well, or you cannot get it to work according
to the user's manual.
19. The equipment has been dropped and damaged.
20. The equipment has obvious signs of breakage.
21. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE
STORAGE TEMPERATURE MAY GO BELOW -30° C (-22° F) OR ABOVE 70° C
(158° F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT
SHOULD BE IN A CONTROLLED ENVIRONMENT.
Operating temperature: 50° C
22. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT
TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED
BATTERIES ACCORDING TO THE MANUFACTURER'S
INSTRUCTIONS.
23. The sound pressure level at the operator's position according to IEC
704-1:1982
is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1.
Advantech disclaims all responsibility for the accuracy of any statements
contained herein.
Wichtige Sicherheishinweise
1.
2.
3.
Bitte lesen sie Sich diese Hinweise sorgfältig durch.
Heben Sie diese Anleitung für den späteren Gebrauch auf.
Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden
Sie Keine Flüssig-oder Aerosolreiniger. Am besten dient ein
angefeuchtetes Tuch zur Reinigung.
4. Die NetzanschluBsteckdose soll nahe dem Gerät angebracht und
leicht zugänglich sein.
5. Das Gerät ist vor Feuchtigkeit zu schützen.
6. Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein
Kippen oder Fallen könnte Verletzungen hervorrufen.
7. Die Belüftungsöffnungen dienen zur Luftzirkulation die das Gerät vor
überhit- zung schützt. Sorgen Sie dafür, daB diese Öffnungen nicht
abgedeckt werden.
8. Beachten Sie beim. AnschluB an das Stromnetz die AnschluBwerte.
9. Verlegen Sie die NetzanschluBleitung so, daB niemand darüber fallen
kann. Es sollte auch nichts auf der Leitung abgestellt werden.
10. Alle Hinweise und Warnungen die sich am Geräten befinden sind zu
beachten.
11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es
vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine
Beschädigung vermieden.
12. Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder
Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw.
elektrischen Schlag aus- lösen.
13. Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen
Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.
14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu
trennen und von einer qualifizierten Servicestelle zu überprüfen:
15. Netzkabel oder Netzstecker sind beschädigt.
16. Flüssigkeit ist in das Gerät eingedrungen.
17. Das Gerät war Feuchtigkeit ausgesetzt.
18. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert
oder
Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen.
19. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.
20. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.
21. VOSICHT: Explisionsgefahr bei unsachgemaben Austausch der
Batterie.Ersatz nur durch densellben order einem vom Hersteller
empfohlene-mahnlichen Typ. Entsorgung gebrauchter Batterien navh
Angaben des Herstellers.
22. ACHTUNG: Es besteht die Explosionsgefahr, falls die Batterie auf nicht
fach- männische Weise gewechselt wird. Verfangen Sie die Batterie nur
gleicher oder entsprechender Type, wie vom Hersteller empfohlen.
Entsorgen Sie Batterien nach Anweisung des Herstellers.
23. Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000
beträgt
70dB(A) oder weiger.
Haft ungsausschluss: Die Bedienungsanleitungen wurden entsprechend
der IEC704-1 erstellt. Advantech lehnt jegliche Verantwortung für die
Richtigkeit der in diesem Zusammenhang getätigten Aussagen ab.
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the products
from damage.
To avoid electrical shock, always disconnect the power from your PC
chassis before you work on it. Don't touch any components on the CPU
card or other cards while the PC is on.
Disconnect power before making any configuration changes. The sudden
rush of power as you connect a jumper or install a card may damage
sensitive electronic components.
Warning!
1. Input voltage rated: 12-24 Vdc.
Transport: carry the unit with both hands and handle with care.
Maintenance: to properly maintain and clean the surfaces, use
only approved products or clean with a dry applicator.
4. CompactFlash: Turn off the power before inserting or removing
CompactFlash storage cards.
2.
3.
European Contact information:
Advantech Europe GmbH
Kolberger Straße 7
D-40599 Düsseldorf, Germany
Tel: 49-211-97477350
Fax: 49-211-97477300
Chapter
General Information This
chapter gives background
information on the TREK-520
Computing Box.
Sections include:
! Introduction
! General Specifications
! Dimensions
1.1
Introduction
The TREK-520 is a dedicated box computer for industrial, transport trucks,
buses and taxis. TREK-520 combined with variety of I/O connectors can be
connected to devices like OBD-II (see Ch3.3) or TPMS (Tire Pressure
Monitoring System) external modules via COM port. Dual display/dual audio
interfaces supporting different resolutions can deliver different applications to
different displays; eg: one application to a driver and another to a digital
signage application.
Built-in wireless communications (WWAN, WLAN, BT) enable TREK-520 to
send important driver/ location/cargo information back to the control center.
TREK-520 can also operate in extreme environments with features like a
wide working temperature range (-30 to 70 degrees). TREK-520 also uses a
special design to handle the critical issue of in power. Special power
protection (ISO7637-2/SAE J1455 Class A/ SAE J1113) and power
management software (Ignition on/off, delay on/off, low battery monitor)
prevent electrical noise and surges from impacting the system, guarding
against damage from transient power.
Rear-Side Connectors
1.2
General Specifications
Key features
z Supports Win CE 6.0 and Linux
z Automotive grade working temperature range (-30° C to 70° C)
z Rich I/O including CAN, RS-232, J1708, Line out, Mic in, USB, min USB Client
z Built-in communication modules, including GSM/GPRS/HSDPA/CDMA,
WLAN & Bluetooth
z GPS with AGPS and dead reckoning technology (speed line)
z Certifications: CE/FCC/e-mark, MIL-SD810F, ISO 7637-2, SAE J1455, SAE
J1113 regulations
z Ignition on/off delay; SW detectable/controllable for power management
1.2.1
General
Dimensions: (W x H x D): 190x134x45.5 mm.
Weight: 900 g.
Power supply:
– Input voltage: 12 ~ 24Vdc, support ignition cold crank
– Ignition on/off
– Low battery shut-down protection threshold (optional): When the
battery voltage level drops below 11V for more than 30 seconds,
TREK-520 will automatically shut down in order to prevent “deep
discharge” situations and TREK-520 can be re-activated only when the
voltage is > 11V.
– Power on delay: Default 2 seconds. When the TREK-520 is powered
on via ignition key, the system will delay 2 seconds to power on.
–
Power off delay: Default 5 seconds. When TREK-520 power is
controlled by ignition key and turns off by the key (ignition=off), the
TREK-520 will start the shut procedure after 5 seconds.
– Hard off delay: Default 30 seconds. When TREK-520 power is
controlled by ignition key and turns off by the key (ignition=off), the
TREK-520 will cut off the 5VSB power after 30 seconds. In this event
when the shutdown process is longer than 30 seconds, the power will
be shut down hard, turning off the TREK-520's power and 5VSB.
Note!
For more detail of function please refer to Chapter 4, Section
4.3.2 of this manual.
Power consumption: The maximum current consumption is about 32.4
watts. The power consumption is 12 watts in normal mode (with only XPE
running; no I/O device and modules connected to the TREK-520).
Front panel and back cover: IP65 Sealed; NEMA4 compliant
(Not including the I/O ports).
Enclosure: Ruggedized aluminum without ventilation holes.
1.2.2
Standard PC Functions
CPU: TI ARM Cortex-A8 AM3703 800MHz
System chipset:.
System memory: On board chip up to 1G
Serial ports: RS-232, smart Display, WLAN,GPS, WWAN, VIO, USB 2.0, Client
Universal serial bus (USB) port: Supports up to three USB2.0.
One from smart display port.
Bluetooth: One Class2 Bluetooth V2.1 + EDR module/ BT 3.0
Watchdog timer: 63-level timer intervals automatically generate system reset
when the system stops due to a program error. Jumper selection
and software enabled/disabled.
RTC Battery: 3.0 V @ 200 mA lithium battery.
Power management: Supports power saving modes including Normal
Standby/Suspend modes.
CAN bus
Audio controller:
Stereo sound:
Audio interface:
Optional modules: 12 channels GPS, quad-band GSM/GPRS, WLAN card
1.2.3
Touchscreen
Type: Analog Resistive
Light transmission: 80%
Controller: RS-232 interface
Power consumption: <5.5 V@ 20 mA
Durability: > 10 million depressions
Software driver: Supports Windows XP/XP Embedded, Win CE
1.2.4
Environment
High/low temperature: -30 ~ 70° C
Relative humidity: 10 ~ 95% @ 40° C (non-condensing)
Shock: 30 G peak acceleration (11 msec duration)
Certifications: CE, FCC, CCC, Emark, CB.
Vibration: 5 ~ 500 Hz SAE J1455 4.9.4.2, MIL-STD-810F 514.5
Dimensions
1.4
Figure 1.1 TREK-520 dimensions
Chapter 2
System Setup
This chapter details system setup
on TREK-550.
Sections include:
! A Quick Tour of the computer box
! Installation Procedures
! Running the BIOS Setup
Program
2.1
A Quick Tour of the TREK-520 Computing box.
Before starting to set up the Computing Box, take a moment to become familiar with the
locations and purposes of the controls, drives, connectors and ports, which are illustrated
in the figures below. When the Computer box is placed inside truck glove cabinet or under
the passenger’s seat next to the driver, its front appears as shown in Figure 2.1.
Figure 2.1. front view of TREK-520
Figure 2.2Rear view of
Figure 2.2. Rear view of TREK-520
2.3
Installing System Software
Recent releases of operating systems from major vendors include setup
programs which load automatically and guide users through the entire
process of operating system installation. The guidelines below help to
determine the steps necessary to install your operating system on the
computer hard drive.
Note!
Some distributors and system integrators may have already
pre- installed system software prior to shipment of your
Mounted
Computer.
The BIOS of the computer supports system boots-up directly from the drive
whenever it is connected using a USB interface.
Power on the computer, or reset the system by pressing the “Ctrl” + “Alt” + “Del”
keys simultaneously. The computer will automatically load the operating
system from the diskette .
When presented with the opening screen of a setup / installation program,
simply fol- low the onscreen instructions. The setup program guides users
through preparations of the hard drive, and installation of the operating system.
When presented with an operating system command prompt, like, A:\>, then it
is nec- essary to partition and format the hard drive, and manually copy the
operating sys- tem files to it. Refer to the operating system user instructions
about partitioning and formatting the hard drive.
Note! The drivers and utilities used for the TREK-520 are subject to change without
notice. If in doubt, check Advantech's website or contact our
application engineers for the latest information regarding
drivers and utilities.
2.4
Programming Function Keys and GPIO/CAN BUS
The Mount Computer provides five function keys, GPIO and CAN bus as
shown in section 2.1. These functions must be activated with the correct
software, that’s why we provide an AP library for customers to design their own
software. Refer to Appendix C for more detail.
Chapter 3
Pin Assignments
This appendix explains pin
assignments on the TREK-520.
3.1 Front Side Connectors
3.2 Rear Side Connectors
Chapter 4
Software demo application setup
This appendix explains the
software demo application for
TREK-520.
Sections include:
! Introduction
! How to set up demo application
4.1
Introduction
To make the hardware easier to access for programmers, Advantech has
developed an demo program in order to let customer test the functions on
TREK-520. This document describes detailed information for each Advantech
demo program so that application developers can become more familiar with
using them.
For technical support, contact Advantech application engineers
worldwide. For news updates, visit our website:
www.advantech.com
4.1.1
Execute J1939 demo program
This section explains how to install the Advantech demo program in Windows
XP Pro / Embedded.
1. Execute the test program called “IMC_Demo”
Figure 4. 1
2. Click J1939: customer may connect directly to the truck; we use a
simulator board below to explain how J1939 protocol can be executed.
First, connect to the simulator board to TREK-520 CAN port and console
PC, once the simulator is powered on (connect to the truck), you can start
getting the data, just click [Read], you may get the data you need from the
simulator, click [Read], you may transfer the data to Console
Smulator vendor name:
21
www.advantech.com
Figure 4.2
Figure 4.3
TREK-520 User Manual
22
www.advantech.com
J1939 truck simulator
Figure 4.4
22
4.1.2
CAN Test
1. CAN: Console PC, install [PCAN_USB-to-CAN] test program, and use
USB to CAN fixture to connect to TREK-520 CAN port.
2. Execute PCAN-View USB→ Set Baud rate 250kBit/s→ Select
[Extended]→OK→ Transmit → New → ID(Hex) key in number → Data key
in any number→[Period] key in 100ms→Click [Extended Frame]→OK.
See below figure 4.
Figure 6. 11
Figure 4. 12
TREK-520 User Manual
23
www.advantech.com
22
Figure 4. 13
3. Then you may read the data of TREK-520 from Console PC, in the same
time, you may also press [Write Data] to write to Console PC. As for Filter
Message, it can filter out the message you don’t need, and keep the
message you need. See below Figure 4.
Figure 4. 14
24
www.advantech.com
4.2
RTC test
Execute “RTC test”
1. For RTC Time setting: You may set year, month, date, and time show as
below.
Figure 4.5
Figure 4.6
Figure 4. 7
Figure 4. 8
25
www.advantech.com
2.
RTC Alarm Setting: You may also set Alarm time; you may wake up the system
by the time you have set. Please refer to below figure 4.
Figure 6.9
4.3
Power Management
4.3.1 Power management Mechanism
Normal Power Management Flow
OFF_EVENT_DELAY
ON_DELAY
T1
T2
Ignition ON
T3
HARD_OFF_DELAY
T4
Ignition OFF
System ON
26
www.advantech.com
T5
System OFF
Send Power
Button Signal
Low Battery Protection
LOW _DELAY
System stays ON
LOW_HARD_DELAY
T8
T6
T7
System OFF
Low Battery is
Detected
Send Power
Button Signal
When the system is ON, and
(1) The battery voltage (DC input) is lower than LOW_THRESHOLD (at T6)
(2) and this situation lasts for LOW_DELAY,
, then the system will send Power Button signal to OS (at T7) to start the shutdown
process.
At this time (T7), the LOW_HARD_DELAY is starting to countdown.
Once LOW_HARD__DELAY is over, the system power is removed abruptly.
Before
T1
T1 ~ T2
T2
T2 ~ T3
T3
T3 ~ T4
T4
T4 ~ T5
T5
T1 The system stays off.
power is fed in, but Ignition is OFF.
Ignition is ON and the ON_DELAY is starting to count down.
This duration is and it is ranged from 1 to 18000 seconds.
Once the ON_DELAY is over, the system will stay On or OFF, depending
on the BIOS setting “POWER-ON after Power Fail”.
If “POWER-ON after Power Fail” is set as ON, the system will be powered
ON.
If “POWER-ON after Power Fail” is set as OF, the system will stay OFF
and you could press the power button to turn on system.
The system is under normal operation.
At this time, the Ignition is OFF, and OFF_EVENT_DELAY is starting to
count down.
This duration is OFF_EVENT_DELAY and it is ranged from 1 to 18000
seconds.
When the OFF_EVENT_DELAY is over, the system will send a power
button signal to the OS and the user application should prepare the
shutdown process.
The HARD_OFF_DELAY is starting to count down.
This duration is HARD_OFF_DELAY and it is ranged from 1 to 18000
seconds.
When the HARD_OFF_DELAY is count to zero, the system power is
removed abruptly to avoid extra and abnormal power drain from battery.
This parameter is fixed with a value of 60 seconds.
www.advantech.com
After
T5
The system stays off.
27
LOW_DELAY is ranged from 1 to 3600 seconds.
LOW_HARD_ DELAY is fixed with a value of 60 seconds.
Note:
Q1: How is the low-battery event raised or canceled?
A1: The minimum value on LOW_DELAY parameter is 1 second. If the voltage remains
lower than the LOW_THRESHOLD in the duration of LOW_DELAY, the low-battery
event will be raised and immediately send a power button press signal to OS.
During the duration of LOW_DELAY, if the battery voltage is back to be higher than
LOW_THRESHOLD, the LOW_DELAY will be reset to predetermined value and stop
count down.
Therefore, the LOW_DELAY parameter acts as a filter to prevent incorrect
low-battery-event from happening.
4.3.2
Power Management demo program
A. Check the files.
Make sure that there are two components include in TREK-520 Power Management
Tool. One is “AdvXP_CAN.dll”, another one is “TREK-520 Power Manager.exe”.
B. Start up the program
Execute Power Management tool and you will see a message box shows “Connect
OK”.
Then Click OK button and you will see the main page as below.
28
www.advantech.com
4.3.3
Power Management Parameter settings
The parameters for power management on TREK-520 could be set by Demo program
(see the image below) or SDK/API.
Figure 4.9 power management demo utility
Figure 4.9 Off event delay
Off Event Delay – it means after 5 seconds delay from receiving of ignition OFF signal,
EC controller will send a shutdown event to make system start shutdown process
Figure 4.9 Hard Off delay
Hard off Delay – it means after 30 seconds from shutdown event, EC controller will
force power cut off at the same time.
29
www.advantech.com
Figure 4.9 On delay
On Delay – it means after 2 seconds from receiving of ignition ON signal, EC controller
will send a power-on event to make system start booting process.
Figure 4.9 Low delay
Low Delay – it means after 30 seconds delay from receiving of Battery Voltage LOW
signal, EC controller will send a shutdown event to make system start shutdown
process.
Figure 4.9 Low hard delay
Low Hard Delay – it means after 60 seconds from Low Voltage shutdown event, EC
controller will force power cut off at the same time
Figure 4.9 Battery voltage Threshold level setting
You could set the LOW battery voltage value by changing level 0 to 65. For example, if
you’re using 12V battery, and you set level as 50, it means the LOW battery voltage
value is 10.147 + 50 x 0.0146 = 10.877 V.
Checks which source you’re connecting. DC supply or 12V or 24V battery.
Figure 4.9 check 12 or 24 battery
Check the ignition signal and see if it’s ON or OFF.
30
www.advantech.com
C. Read current status
The buttons which indicates by red squares can READ the current status of the system.
31
www.advantech.com
Figure 4.9 Read the value
D. Set the value
The buttons which indicates by blue squares can SET the value you want to the
system.
32
www.advantech.com
Figure 4.9 Set value
Execute “Power management test”, the Battery Voltage Level has 12V and
24V, you may set from 0~65 levels, press “Get” to know the value you set.
Figure 4.10
1. Off Event Delay: You may set how many seconds you want system auto
shut down after ignition off.
2. On Delay: You may set how many seconds you want the system to auto
power on.
3. Low Delay: When the battery voltage is below certain value you set, it will
automatically shut down to prevent the system will consume the battery.
4.3.4
TREK-520 power consumption
OS: Windows Embedded Standard
Burn-in test V6.0
Idle Mode
w/o
TREK-303H
w/ TREK-303H
12V / 1.04A
www.advantech.com
Off mode (S5)
12V / 1.75mA
12V / 1.51A
*Doesn’t support S1, S3, S4
33
100% Burn-in Test
Mode
12V / 1.20A
12V / 1.94A
4.4
Dead reckoning
We will need a 3-axis accelerometer that our software can talk to.
We use this to characterize driver behavior such as hard
accelerations, braking, and cornering. This also can tell us other
significant information that can be used in accident reconstruction,
etc… This one of the crucial items that we asked for in our
specification and our customers’ expectations are making this a
definite must have in our system. We won’t be needing any dead
reckoning functionality at this point in time… this is something we
may want to include in the future but in order to get cost down we
have decided to forgo this at this time. Please confirm that we will
have access to this or another accelerometer.
4.5
G- sensor
We currently, we don’t have documents about G-sensor, but a code
example is ready for customer reference. This code example ONLY
introduces how to access the G-sensor under Windows XP/XPe, but
users must control the G-sensor and develop their SW application by
themselves. Therefore, customer can decide how to set the
sensitivity value when to trigger G-sensor to send signal to CPU and
to back end server through WWAN module. G-sensor is located on
the motherboard inside the TREK-520. Please refer the link
(http://www.analog.com/static/imported-files/data_sheets/ADXL345.
pdf) for the G-sensor datasheet.
34
www.advantech.com
Appendix
This appendix explains the
TREK-303 detailed information.
35
www.advantech.com
Appendix A Paired with TREK-303 Specifications
Table 1.1: TREK-303 Specifications
Definition
Detail Display
7” TFT LCD Max.
type:
resolution:
800 x 480
Colors:
262K
Dot size (mm)
0.0635 x 0.1905
Luminance:
500 cd/m2
Viewing Angle (R/L/B/T)
70° / 70°/ 60°/ 60°
Note!
1.
36
www.advantech.com
The Brightness control is adjusted by the auto light sensor
in the front panel as default; it is also defined by button on
the front panel by manual.
2. The color LCD display
TREK-303 Specification
TREK-303 demo SW application program
Figure 6. 17
37
www.advantech.com
1. Execute “Hot Key test” program Î
2. Brightness level: You may set panel’s brightness from level 0 ~10,
total 10 levels, when you finish setting the brightness level you want,
please click “Apply”. If you want to check the current brightness level of
TREK-303, please click “Get”.
3. Duty cycle: You may set every level’s brightness strength, total 10
levels, when you finish setting the brightness strength for each level,
please click “Apply”. If you want to check the current brightness
strength on certain level of TREK-303, please click “Get”.
4. Light sensor: When the sensor has detected the change of the
brightness in the environment, the value will change. The lowest level
of brightness, the lowest value it is presented. On the contrary, the
highest level of brightness, the highest value it is presented.
5. Hotkey: You may set the hotkey LED light brightness, the value is from
0 ~100.
6. Key Status: When you press Hot key, the status will change from 0 to
1.
7. Key function Definition: You may set the parameter to connect the
application program of the hot key.
38
www.advantech.com
www.advantech.com
Please verify specifications before quoting. This guide is intended for
reference purposes only.
All product specifications are subject to change without notice.
No part of this publication may be reproduced in any form or by any
means, electronic, photocopying, recording or otherwise, without prior
written permission of the publisher.
All brand and product names are trademarks or registered trademarks
of their respective companies.
© Advantech Co., Ltd. 2010
39
www.advantech.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract
Create Date                     : 2014:07:09 17:03:49+08:00
Modify Date                     : 2014:07:11 10:02:01+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Metadata Date                   : 2014:07:11 10:02:01+08:00
Document ID                     : uuid:ea426a19-3c33-43d1-9e2f-6b5c0248fd5a
Instance ID                     : uuid:b8948ce3-730d-4541-b1f6-034c9755c3d7
Format                          : application/pdf
Title                           : untitled
Page Count                      : 39
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M82-TREK520

Navigation menu