Aeon Labs DSB45 WATER SENSOR User Manual water sensor englise manual

Aeon Labs LLC. WATER SENSOR water sensor englise manual

User Manual

View the expanded manual:http://aeot.ec/spprt/watersensorWater SensorMetalNonmetallicNonmetallicIron platesWaterAeotec by Aeon Labs Water SensorYour  Z-Wave  system  is  only  as  good  as  it  is  smart. Aeotec by  Aeon  Labs’  Water  Sensor  brings  it  a  new  level  of inte l l i g e n c e ,  one  that  is  suited  to  both  safety  and convenience.  Capable  of  detecting  either  the  presence  or absence of water to as little as 3% of an inch, each sensor is crafted into the smallest and most subtle of packages.Familiarise  yourself with your sensorIron plateWater Sensor ScrewAAA BatteryDouble-SidedMounting TapePackage Contents:Water Sensor                                       ×1Iron Plate                                              ×1                                Screw                                                    ×2AAA Battery                                          ×2Double-Sided Mounting Tape             ×2Quick StartYour  Aeotec  by  Aeon  Labs’  Water  Sensor  is  capable  of detecting  the  presence  or  absence  of  water.  Choosing  the scenario  you  want  will  help  you  determine  where  best  to place  your  sensor.  The  most  common  scenario  is  the detection  of  leaking  water  from  the  likes  of  a  hot  water system  or  an  air  conditioner.  In  other  instances  you  may wish  to  detect  when  the  level  of  water  in  a  tank  has decreased passed a certain level.ProbePrepare your Water SensorThe first step is to activate your Water Sensor1. Take out the back shell of Water Sensor  2. Remove the clear battery insulator by pulling it away from     the Water SensorWith the battery insulator removed,  your Water  Sensorpowered  and  activated.  It  is  now  time  prepare  to  install your Water Sensor.3. Choosing a position for the Water probeThe  following  tips  will  help  you  select  a  position  that  will optimise      the performance of your water probe.If  detecting  the  presence  of  water,  your  probe’s  two  prongs should sit flat against the surface where water will collect.WaterIf  detecting  the  absence  of  water,  your  probe’s  two  prongs should sit at the minimum water level you want.If  detecting  the  absence  of  water,  it’s  fine  to  submerge  your probe in water - it’s waterproof.Choosing a position for the Water SensorThe  following  tips  will  help  you  select  a  position  that  will optimise the performance of your Water Sensor.Your water  sensor is not waterproof or weatherproof, as such you  should  not  place it  in  any  area  where  it is  likely  to  get  wet. This  includes  not  placing  it  directly  underneath  objects  which you may be monitoring for leaks, such as water heaters.For  an  optimal  wireless  signal,  position  your  Water  Sensor  1 meter off of the ground. Additionally, for  an  optimal  wireless  signal  mount  your  Water Sensor with its longest side vertical.Will  have  an  optimal  wireless  signal  when  affixed  1  meter  or above your home's floor.Placed  within  30  meters  of  another  Z-Wave  device  that  is either a gateway or not powered by batteries.If  outdoors  should  be  protected  from  the  elements  -  such  as inside a recess or within a waterproof boxKeep DryInstallation your Water Probe Once  you've  selected  the  best  position  for  both  parts  of  your Water  Sensor  to  be  installed,  it's  time  to  affix  both  to  their respective surfaces.1. Affixing your water probe’s mounting plateThere  is  a  magnet  inside  the  water  probe,  if  you’ve  sure  the position where  your  water  probe  should install,  only  adsorption your water probe up to a metal.If you can’t find the metal to affixing your water probe. Use the Iron plates .1. installation your Water Sensor Your water sensor ’s mounting plate can be affixed using screws or double-sided tape. You  needn't worry  about which end  is the top or the bottom, they can be mounted with either end at the top - they're bidirectional.If  using  screws,  attach  your  water  sensor’s  mounting  plate using  the  screws.  If  either  surface  is  soft,  plasterboard  for instance, use the screw anchors.If mounting  your  water  sensor  indoors  in an  area  where itself won't  be  exposed  to  condensation  or  moisture  in  the  air,  it  is possible to use mounting tape to affix it to a wall. To begin, wipe the respective surface clean of any oil or dust. When the surface has  dried,  peel  one  side  of  the  tape  back  and  attach  it  to  the corresponding section on the rear of main mounting plate.Probe3Adding your Water Sensor to Z-Wave networkWith  your  mounting  plates prepared to  hold each component of your sensor, it’s time to add it to your Z-Wave network.On  the  rear  of  your  water  sensor,  remove  the  spacing  tab  to connect the batteries. Your water sensor’s LED will blink for 3 seconds.Press the Z-Wave button on your primary Z-Wave controller / gateway.  If  you’re  unsure  of  how  to  do  this,  refer  to  its  user manual.Press the Z-Wave button on your water sensor. If it has been successfully  added  to  your  Z-Wave  network,  its  LED  will1.2.3.
Z-WaveWake UpAssociate your Water Sensor with other Z-Wave devicesIt's  possible  to  use  your  Aeotec  by  Aeon  Labs’s  Water Sensor  to  talk  to  more  than  just  your  gateway.  As  an example,  you  can  create  an  automation  activity  that  would activate a siren when water is detected.1.Set  gateway  sent Association  set  command,  and  Assign route command to Water Sensor.Then  press  and  hold  Z-Wave  button  of  Water  Sensor  3 seconds.  Water  Sensor  will  sent  wake  up  notification  to gateway.After gateway received the wake up notification, Gateway will sent preset commands to Water Sensor. Your Water Sensor is capable of directly controlling 5 other Z-Wave devices within your Z-Wave network. The following association  steps  are  performed  automatically  if  your primary Z-Wave controller / gateway is either a SUC (Static Update  Controller)  or  a SIS  (SUC  ID  Server).  When  this  is the case, you'll need to create automation activities directly through  your  controller  / gateway -  refer to  its  user  manual for further information.illuminate  for  10  minutes.  During  this  period  your  primary  Z-Wave controller / gateway is able to configure your sensor.Your sensor will then automatically exit setup mode at the end of 10 minutes. 4.2.3.Remove your Water Sensor from Z-Wave networkYour  sensor  can  be  removed  from  your  Z-Wave  network  at any  time.  You'll  need  to  use  the  main  controller  in  your  Z-Wave network  to do this. The following instructions tell you how  to  do  this  using  Aeotec  by  Aeon  Labs’s  Z-Stick  and Minimote  controllers.  If  you  are  using  other  products  as your main Z-Wave controller, please refer to the part of their respective manuals that tells you how remove devices from your network.If you are using a Z-StickIf  your  Z-Stick  is  plugged  into  a  gateway  or  a  computer, unplug it. Take your Z-Stick to your sensor. Press  the  Z-Wave  Button  on  your  Z-Stick  and  hold  for  3 seconds.Press the Z-Wave button on your sensor.If  your  sensor  has  been  successfully  removed  from  your network,  its  LED  will  blink  for  3  seconds.  If  the  removal was unsuccessful the light will be solid for 3 seconds after pressing your sensor's Inclusion button.Press  the  Z-Wave  Button  on  the  Z-Stick  again  to  take  it out of removal mode.1.2.3.4.5.6.If you are using a MinimoteTake your Minimote to your sensor.Press Remove button on your Minimote.Press the Z-Wave button on your sensor.If  your  sensor  has  been  successfully  removed  from  your network,  its  LED  will  blink  for  3  seconds.  If  the  removal was unsuccessful the light will be solid for 3 seconds after pressing your sensor's Inclusion button.Press  any  button  on  your  Minimote  to  take  it  out  of removal mode.1.2.3.4.5.4Send wake up notification4In  order  to  send  your  sensor  new  configuration  commands from  your  Z-Wave  controller  or  gateway,  it'll  need  to  be woken up.Remove  your  Water  Sensor  from  its  mounting  plate  by pressing down on the latch button and pulling it away from its mounting plate.Press  the  Wake-up  Button  3  times  quickly  on  the  rear  of your  sensor.  Your  sensor  will  now  remain  awake  for  10 minutes. When  done,  return  your  Water  Sensor  to  its  mounting plate. To do  this  align the  plate's  hitch  with  your  sensor's hitch  hole,  and  push  the  top  of  your  sensor  into  the mounting plate until the two parts click firmly together.1.2.3.Reset all your sensor’s configurations5Press  and  hold  the  Z-Wave  button  on  the  rear  of  your Water Sensor for 20 seconds.Your  Water  Sensor  will  reset  to  its  factory  default configuration.  Its  LED  will  blink  for  3  seconds  to  let  you know it was reset successfully.1.2.Should  you  wish  to  reset  all  your  sensor's  configurations, you are able to reset it to its factory defaults.Your  water  sensor's  configurations  will  also  be  reset  to factory defaults if you remove it from your Z-Wave network.Technical specifications6Operating distance: Up to 100 feet / 30 meters indoors and 300 feet / 100 meters outdoors.Operating temperature: -35℃ to +60℃.Aeon  Labs  warrants  to  the  original  purchaser  of  Products that  for  the  Warranty  Period  (as  defined  below),  the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation,  operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer.  Warranty claims must be made by Customer in writing within thirty (30) days of the manifestation of a problem. Aeon Labs' sole obligation  under  the  foregoing  warranty  is,  at  Aeon  Labs' option, to repair, replace or correct any such defect that was present  at  the  time  of  delivery,  or  to  remove  the  Products and to refund the purchase price to Customer. Warranty 7The  "Warranty  Period"  begins  on  the  date  the  Products  is delivered and continues for 12 months. Any  repairs  under  this  warranty  must  be  conducted  by  an authorized  Aeon  Labs  service  representative  and  under Aeon  Labs'  RMA policy.  Any repairs conducted by unauthorized persons shall void this warranty.Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war, strikes,  fires,  other  catastrophes,  misuse,  misapplication, storage damage, negligence, electrical power problems, or modification to the Products or its components. Aeon  Labs  does  not  authorize  any  person  or  party  to assume  or  create  for  it  any  other  obligation  or  liability  in connection with the Products except as set forth herein. Aeon  Labs  will  pass  on  to  Customer  all  manufacturers' Material warranties to the extent that they are transferable, but will not independently warrant any Material.Customer must prepay shipping and transportation charges for  returned  Products,  and  insure  the  shipment  or  accept the  risk  of  loss  or  damage  during  such  shipment  and transportation.  Aeon  Labs  wi ll  ship  the  repaired  or replacement products to Customer freight prepaid.Customer shall indemnify, defend, and hold Aeon Labs and Aeon  Labs'  affiliates,  shareholders,  directors,  officers, employees,  contractors,  agents  and  other  representatives harmless  from  all  demands,  claims,  actions,  causes  of action, proceedings, suits, assessments, losses, damages, lia b il itie s ,  set tl emen t s,  ju d gmen t s,  fi n es,  p en alti e s, in te r es t,  c o st s  a nd  ex pe n s e s  ( in cl u di ng  fe es  a n d disbursements  of  counsel)  of  every  kind  (i)  based  upon personal  injury  or  death  or  injury  to  property  to  the  extent any  of  the  foregoing  is  proximately  caused  either  by  a defective  product  (including  strict  liability  in  tort)  or  by  the negligent  or  willful  acts  or  omissions  of  Customer  or  its officers,  employees,  subcontractors  or  agents,  and/or  (ii) arising from or relating to any actual or alleged infringement or  misappropriation  of  any  patent,  trademark,  mask  work, copyright,  trade  secret  or any actual  or alleged violation of any  other  intellectual  property  rights  arising  from  or  in connection with the products, except to the extent that such infringement exists as a result of Aeon Labs' manufacturing processes.IN  NO  EVENT  SHALL  AEON  LABS  BE  LIABLE  FOR  ANY IN DI RE C T,  I N C ID EN TA L,  P U NI TI VE ,  S PE C IA L  O R CONSEQUENTIAL  DAMAGES,  OR  DAMAGES  FOR  LOSS OF  PRO F I TS ,  REVE N U E,  OR  US E  INCURR E D  B Y CUSTOMER  OR  ANY  THIRD  PARTY,  WHETHER  IN  AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED  OF  THE  POSSIBILITY  OF  SUCH  DAMAGES.   AEON  LABS'  LIABILITY  AND  CUSTOMER'S  EXCLUSIVE REMEDY  FOR  ANY  CAUSE  OF  ACTION  ARISING  IN CONNECTION  WITH  THIS  AGREEMENT  OR  THE  SALE OR  USE  OF  THE  PRODUCTS,  WHETHER  BASED  ON N E G L I G E N C E ,  S T R I C T  L I A B I L I T Y,   B R E A C H   O F WARRANTY,  BREACH  OF AGREEMENT,  OR  EQUITABLE PRINCIPLES,  IS  EXPRESSLY  LIMITED  TO,  AT  AEON LABS' OPTION, REPLACEMENT OF, OR  REPAYMENT OF THE  PUR C HASE  PRI C E  FO R  T HAT  P O RT IO N  OF PRODUCTS  WITH  RESPECT  TO  WHICH  DAMAGES  ARE CLAIMED.    ALL  CLAIMS  OF  ANY  KIND  ARISING  IN CONNECTION  WITH  THIS  AGREEMENT  OR  THE  SALE OR  USE  OF  PRODUCTS  SHALL  BE  DEEMED  WAIVED UNLESS  MADE  IN  WRITING  WITHIN  THIRTY  (30)  DAYS FROM  AEON  LABS'S  DELIVERY,  OR  THE  DATE  FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY. TH E  INDEMNIT Y  AND  WA RRANTY  IN  ABOVE  A RE EXCLUSIVE  AND  IN  LIEU  OF  ALL  OTHER  INDEMNITIES OR  WARRANTIES,  WHETHER  EXPRESS  OR  IMPLIED, I N C L U D I N G   T H E   I M P L I E D   W A R R A N T I E S  O F  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR PURPOSE.THE  MANUFACTURER  IS  NOT  RESPONSIBLE  FOR ANY  RADIO  OR  TV  INTERFERENCE  CAUSED BY U N A U T H O R I Z E D   M O D I F I C A T I O N S   T O   T H I S  EQUIPMENT.  SUCH  MODIFICATIONS COULD  VOID T H E  U S E R 'S  A U T H O R I T Y  T O  O P E R AT E  T H E EQUIPMENT.This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions:This device may not cause harmful interference.This  device  must  accept  any  interference  received, including  interference  that  may  cause  undesired operation. This equipment has  been tested and found to  comply  with  the  limits  for  a  Class  B  digital  device, pursuant to part 15 of the FCC Rules. These limits are designed  to  provide  reasonable  protection  against harmful  interference  in  a  residential  installation.  This equipment  generates,  uses  and  can  radiate  radio frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may  cause  harmful interference to radio communications. However, there is  no  guarantee  that  interference  will  not  occur  in  a particular  installation.  If  this  equipment  does  cause harmful  interference  to  radio  or  television  reception, which can be determined by turning the equipment off and  on,  the  user  is  encouraged  to  try  to  correct  the int e rfer e nc e  by  o ne  o r  mor e  of  t h e  fo l lo wing measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment  into  an  outlet  on  a  circuit   diffe r ent  f rom  t ha t  to  w hich  the  rec ei ver  i s connected.Consul  the  dealer  or  an  experienced  radio/TV technician for help.1.2.FCC NOTICE(for USA)Do  not  dispose  of  electrical  appliances  as  unsorted municipal waste, use separate collection facilities.Contact your local government for information regarding the collection systems available.WarningVersion:501004500001-AA www.aeotec.comCertifications (regional):

Navigation menu