Aeon Labs FT111 In-Wall Dimmer, Nano Dimmer User Manual 15 FT111 A UserMan

Aeon Labs LLC. In-Wall Dimmer, Nano Dimmer 15 FT111 A UserMan

15_FT111-A UserMan

Download: Aeon Labs FT111 In-Wall Dimmer, Nano Dimmer User Manual 15 FT111 A UserMan
Mirror Download [FCC.gov]Aeon Labs FT111 In-Wall Dimmer, Nano Dimmer User Manual 15 FT111 A UserMan
Document ID3245742
Application IDRZJNGaaBlnezEuHZn2568g==
Document Description15_FT111-A UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize165.38kB (2067219 bits)
Date Submitted2017-01-04 00:00:00
Date Available2017-01-04 00:00:00
Creation Date2016-12-06 15:50:03
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2016-12-27 17:32:10
Document Title15_FT111-A UserMan
Document CreatorAdobe InDesign CS6 (Windows)

Fantem
In-wall Dimmer
Nano Dimmer
View the expanded manual:
http://aeotec.com/support
IMPORTANT!
This product has been fully tested and certified to
work with Z-Wave by the Z-Wave Alliance. It is
crafted using Z-Wave Plus, the latest device version
of Z-Wave. As such, if the product does not work
with your gateway, please be sure to check with your
gateway manufacturer that they have integrated this
device with their gateway for full operation.
1
Warning
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information
regarding the collection systems available.
Certifications (regional):
Z-Wave and Z-Wave Plus are
registered trademarks of Sigma
Designs and its subsidiaries in the
United States and other countries
FCC ID: XBAFT111
Aeotec by Aeon Labs Nano Dimmer.
Aeotec Nano Dimmer is a Z-Wave smart dimmer
device specifically used to enable Z-Wave command
and control (on/off/dim) of any in-wall switches.
It can report immediate wattage consumption or
kWh energy usage over a period of time. In the
event of power failure, non-volatile memory retains
all programmed information relating to the unit’s
operating status.
It can connect to 2 external manual switches to
control the load ON/OFF independently. Its surface
has a pin socket, which can be used for connecting
to the touch panel, so you can also use the touch
panel to control the Nano Dimmer.
The Nano Dimmer is also a security Z-Wave plus
device and supports Over The Air (OTA) feature for
the products firmware upgrade.
Version: 501011100001-AA
32
www.aeotec.com
2 Familiarize yourself with your Nano
Dimmer.
RF antenna
Touch panel connection port
RGB LED
Fastening screws
Action Button
to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a
circuit different from that to which the receiver
is connected.
Consul the dealer or an experienced radio/TV
technician for help.
UL NOTICE (For USA/Canada).
(Front)
(Back)
(Bottom)
Wire connection
port
1. Install only in a UL listed junction box sized
3×2×2.75 inch (75×50×70 mm) or larger,
minimum volume 14 in3 (230 cm3 ).
2. Use Copper Conductors Only.
3. “CAUTION – Risk of Electric Shock – More than
one disconnect switch may be required to deenergize the equipment before servicing”.
4. “WARNING - This device shall not be used in
combination with a wall switch controlling a
receptacle.”
31
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference,
and
2. This device must accept any interference received,
including interference that may cause undesired
operation. This equipment has been tested and
found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment generates,
uses and can radiate radio frequency energy
and, if not installed and used in accordance with
the instructions, may cause harmful interference
to radio communications. However, there is
no guarantee that interference will not occur in
a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment off and on, the user is encouraged
30
OUT
COM
S1
S2
Touch panel
Notes for the wire connection ports:
L – Power input for live
N – Power input for neutral
OUT – Output for load
COM – Common port for all External switches (S1
and S2)
S1 – External switch 1 control for load
S2 – External switch 2 control for load
Install the Nano Dimmer.
Important: A licensed electrician with knowledge
and understanding electrician systems and electrical
safety should complete the electrical installation.
1. Shut off the main circuit breaker of your home for
safety during the installation and ensure the wires
are not short circuited during the installation which
will cause damage to the Nano Dimmer.
WITHIN THIRTY (30) DAYS FROM AEON LABS'
DELIVERY, OR THE DATE FIXED FOR DELIVERY IN
THE EVENT OF NONDELIVERY. THE INDEMNITY
AND WARRANTY IN ABOVE ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER INDEMNITIES
OR WARRANTIES, WHETHER EXPRESS OR
IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
FCC NOTICE (for USA)
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT.SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT.
Note: Your home’s main circuit breaker must support
the overload protection for safety.
STORE INDOORS WHEN NOT IN USE. SUITABLE
FOR DRY LOCATIONS. DO NOT IMMERSE
IN WATER. NOT FOR USE WHERE DIRECTLY
EXPOSED TO WATER.
29
DAMAGES FOR LOSS OF PROFITS, REVENUE,
OR USE INCURRED BYCUSTOMER, COMPANY
OR ANY THIRD PARTY, WHETHER IN AN ACTION
IN CONTRACT, OR TORT, OR OTHERWISE
EVENIF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. AEON LABS' LIABILITY AND
CUSTOMER'S EXCLUSIVE REMEDY FOR ANY
CAUSE OF ACTION ARISING IN CONNECTION
WITH THIS AGREEMENT OR THE SALE OR
USE OF THE PRODUCTS, WHETHER BASED
ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR
EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED
TO, AT AEON LABS' OPTION, REPLACEMENT
OF, OR REPAYMENT OF THE PURCHASE
PRICE FOR THAT PORTION OF PRODUCTS
WITHRESPECT TO WHICH DAMAGES ARE
CLAIMED. ALL CLAIMS OF ANY KIND ARISING
IN CONNECTION WITH THIS AGREEMENT OR
THE SALE OR USE OF PRODUCTS SHALL BE
DEEMED WAIVED UNLESS MADE IN WRITING
28
2. Preparing connection wires
14 AWG or 12 AWG power wires for Input/
Output.
18 AWG copper wires for external manual switch.
Use the wire stripper cut the metallic part of the
connection wire and make sure the length of the
metallic part is about 5mm.
0.27"
(5mm)
Cut wire if neccessary
Strip Gage (measure barehere)
Note: All connection wires need to be flexible cable.
Wiring diagram of 3-Wire system.
OUT COM S1
S2
Touch panel
Live
Neutral
Wiring diagram of 2-Wire system.
all demands, claims, actions, causes of action,
proceedings, suits, assessments, losses, damages,
liabilities, settlements, judgments, fines, penalties,
interest, costs and expenses (including fees and
disbursements of counsel) of every kind (i) based
upon personal injury or death or injury to property
to the extent any of the foregoing is proximately
caused either by a defective product (including strict
liability in tort) or by the negligent or willful acts or
omissions of Customer or its officers, employees,
subcontractors or agents, and/or (ii) arising from
or relating to any actual or alleged infringement or
misappropriation of any patent, trademark, mask
work, copyright, trade secret or any actual or alleged
violation of any other intellectual property rights
arising from or in connection with the products,
except to the extent that such infringement exists as
a result of Aeon Labs' manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE
FOR ANY INDIRECT, INCIDENTAL, PUNITIVE,
SPECIAL OR CONSEQUENTIAL DAMAGES, OR
27
damage, negligence, electrical power problems, or
modification to the Products or its components.
Aeon Labs does not authorize any person or party
to assume or create for it any other obligation or
liability in connection with the Products except as
set forth herein. Aeon Labs will pass on to Company
all manufacturers’ Material warranties to the extent
that they are transferable, but will not independently
warrant any Material. Company will assist Customer
with all warranty, repair, return and technical support
needs, Company must prepay shipping and
transportation charges for returned Products, and
insure the shipment or accept the risk of loss or
damage during such shipment and transportation.
Aeon Labs will ship the repaired or replacement
products to Company freight prepaid.Customer
and Company shall indemnify, defend, and hold
Aeon Labs and Aeon Labs' affiliates, shareholders,
directors, officers, employees, contractors,
agents and other representatives harmless from
26
N OUT COM S1
S2
Touch
panel
Live
Neutral
Note: The “N” terminal should be connected to the
“L” terminal when the Nano Dimmer is installed by
2-Wire system.
You may need to connect a small power load (E.g.
a LED light or a compact fluorescent lamp) to be
controlled. In this case, the Nano Dimmer may not
get enough power from the AC power supply, so a
bypass can be added to act as a dummy load to
keep your Nano Dimmer get enough power from
the power supply. It can also keep your light from
flickering when diming off the light.
OUT COM S1
S2
Touch
panel
Bypass
Live
Neutral
and the operating manual supplied. Warranty claims
must be made to the Company who you have
purchased from in writing within thirty (30) days of
the manifestation of a problem.
Aeon Labs' sole obligation under the foregoing
warranty is, at Aeon Labs' option, to repair, replace
or correct any such defect that was present at the
time of delivery, or to remove the Products and to
refund the purchase price to Company.
The Warranty Period begins on the date the
Products is delivered and continues for 12 months.
Any repairs under this warranty must be conducted
by an authorized Aeon Labs service representative
and under Aeon Labs' RMA policy. Any repairs
conducted by unauthorized persons shall void this
warranty.
Excluded from the warranty are problems
due to accidents, acts of God, civil or military
authority, civil disturbance, war, strikes, fires, other
catastrophes, misuse, misapplication, storage
25
subsequent to your products’ warranty, please get in
touch with our support team via http://aeotec.com/
support. The Company you bought this product
from has also guaranteed to assist you with any of
your support needs, and you can also contact them
for accordingly.
This guarantee made by the company who you
purchased the product from includes the transfer of
Aeon Labs’ full warranty to that Company. They’ve
guaranteed that they’ll be able to assist you, the
Customer, with all technical support and repair
needs on our behalf.
Aeon Labs warrants to the original purchaser of
Products, that is the Company who you have
purchased from, that for the Warranty Period (as
defined below), the Products will be free from
material defects in materials and workmanship.
The foregoing warranty is subject to the proper
installation, operation and maintenance of the
Products in accordance with installation instructions
24
or
OUT COM S1
S2
Touch
panel
Bypass
Live
Neutral
All above wiring diagrams show that the Nano
Dimmer uses 2-Way or momentary button switches
as the external manual switch.
The below diagram will show you that the Nano
Dimmer uses the SPDT (Single-Pole Double-Throw)
switches as the external manual switch.
Wiring diagram of SPDT as the external manual
switch.
N OUT COM S1 S2
Control ability
Touch panel
3-Way Switch (SPDT)
3-Way Switch (SPDT)
Live
Neutral
Since the S1 port and S2 port can be used to
control the load separately, you can choose to
connect the SPDT switches to the S1 or S2.
10
Model number: FT111-A/ZW111-A
Power input: AC 120V, 60Hz. Rated output: Max
1.2A.
Max standby power: <0.8W.
Power measurement accuracy: ±3W.
Operating temperature: 0℃ to 40℃ /32 ℉ to 104 ℉ .
Relative humidity: 8% to 80%.
Operating distance: Up to 492 feet/150 meters
outdoors.
Supported Loads:
Supported load types
With dimming
Incandescent bulbs, halogen bulbs
function (On/Off/ with or without electronic transformer,
dimmable LED bulbs, dimmable
Dim control)
compact fluorescent lamps.
Without dimming
function (On/Off
control)
Non-dimmable bulbs (Compact
fluorescent lamps with electronic
rectifier, fluorescent tube lamps with
electronic ballast, LED bulbs).
Warranty.
If you are in need of any technical support during or
23
mode.
2. Press the Action Button 2 times within 1 second
on the Nano Dimmer, the blue LED (secure
indication) will blink to indicate the Nano Dimmer
is entering into secure pairing mode.
3. If the Nano Dimmer has been successfully added
to your Z-Wave network, its RGB LED will be
solid. If the pairing was unsuccessful, the red
LED will be on for 2 seconds and then remain a
colourful gradient, repeat the instructions above
from step 1.
Reset your Nano Dimmer.
If at some stage, your primary controller is missing
or inoperable, you may wish to reset all of your
Nano Dimmer’s settings to their factory defaults.
To do this, press and hold the Action Button for 20
seconds and then release it. Your Nano Dimmer will
now be reset to its original settings, and the green
LED will be solid for 2 seconds and then remain the
colourful gradient status as a confirmation.
6 Technical specifications.
22
3. Install Nano Dimmer to the gang box.
a. Live/Hot wire connection: Connect the Live/Hot
wire to the “L” terminal on the Nano Dimmer.
b. Neutral wire connection: Connect the Neutral
wire to the “N” terminal on the Nano Dimmer.
c. Load wire connection: Connect the Load wire
to the “OUT” on the Nano Dimmer.
d. External/manual Switch connection: Connect
2 18AWG wires to the “S1” and “S2” on the
Nano Dimmer.
e. External/manual Switch connection: Connect
2 18AWG wires form the 2 terminals on the
External/manual Switch to the “COM” on the
Nano Dimmer.
OUT COM S1
S2
11
Note: The above physical connection diagram is for
3-Wire system, the below diagram would be for the
2-Wire system.
OUT COM S1
S2
In 2-Wire system, since the power input terminals
of Nano Dimmer just need to connect one power
wire, so the terminal of “N” on Nano Dimmer should
connect to the “L” on the Nano Dimmer.
4. Mounting the gang box.
a. Position all wires to provide room for the device.
Place the Nano Dimmer inside the gang box
towards the back of the box.
b. Position the antenna towards the back of the
12
operation manual for these control points for specific
instructions on monitoring the Nano Dimmer.
Security or Non-security feature of your Nano
Dimmer in Z-Wave network.
Including Nano Dimmer as a non-secure device:
If you want your Nano Dimmer as a non-secure
device in your Z-Wave network, press the Action
Button once on Nano Dimmer when you pair it to
your gateway. If inclusion is successful, the green
LED will be on for 2 seconds, and then return to a
solid indication. If inclusion is unsuccessful, the red
LED will be on for 2 seconds and then return to a
colourful gradient.
Including Nano Dimmer as a secure device:
In order to take full advantage of the Nano Dimmer,
you will want your Nano Dimmer as a security device
that uses encrypted messages to communicate in
your Z-wave network. A security enabled controller/
gateway (or Z-Wave Plus controller) is required.
1. Set your Z-Wave Plus controller into pairing
21
panel. When you have already connected it to the
Nano Dimmer, you will be possible to control the
Nano Dimmer through the Touch panel directly.
box, away from all other wiring.
c. Reinstall the Nano Dimmer to the gang box.
d. Reinstall the cover onto the gang box.
Monitoring Energy Consumption.
The Aeotec Nano Dimmer can report wattage
energy usage or kWh energy usage to a Z-Wave
control point when requested. If this function
is supported by the control points, the energy
consumption will be displayed in the user interface
of the control points. (The specific Z-Wave
commands supporting energy monitoring are the
Meter Command Class. Automatic reports are
sent to association group 1, which is setup via the
Association Command Class.) Please consult the
20
(3-Wire system)
(2-Wire system)
13
Note:
1). The gang box should be sized 3×2×2.75 inch/
75×50×70 mm or larger, minimum volume 14
in3 / 230cm3.
2). Use flexible copper conductors only.
3). If a Bypass installation is needed, the Bypass
should be in parallel with the bulb load, see
below:
Bypass
Warning: The main circuit breaker or fuse must
be shut off during the Bypass installation or bulb
change.
5. Restore Power.
Restore power at the main circuit breaker or fuse.
14
The Nano Dimmer can be controlled via 2-state
(flip/flop) external/manual switch, momentary push
button or the 3-way switch. To automatically detect
and set the mode to the appropriate type of manual
switch wired into Nano Dimmer, toggle the button
on the manual switch once and wait 2 seconds
for the Nano Dimmer to detect the type of manual
switch.
You can also set the external switch mode through
Configuration Command Class.
Parameter 120 [1 byte dec] is the parameter that
will set one of the 3 different modes. If you set this
configuration to:
(0) Enter automatic identification mode
(1) Momentary push button mode
(2) 3-way switch mode
(3) 2-state switch mode
Touch panel control.
As you can see that the Nano Dimmer’s surface has
a pin port, this port is used to connect the Touch
19
Your Nano Dimmer can be removed from your
Z-Wave network at any time. You’ll need to use
your Z-Wave network’s main controller. To set your
Z-Wave controller/gateway into removal mode,
please refer to the respective section within your
controller instruction manual.
1. Set your Z-Wave controller into removal mode.
2. Press the Action Button on the Nano Dimmer or
toggle the external manual switch 2 times in fast
succession.
3. If the Nano Dimmer has been successfully
removed from your Z-Wave network, its RGB
LED will remain colourful gradient. If the removal
was unsuccessful, the RGB LED will still be solid
(following the state of the output load), repeat the
instructions above from step 1.
5 Advanced functions.
Changing mode on the External Switch/Button
Control.
18
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
When the Nano Dimmer is powered on, it will
automatically identify the connected load type and
then match it.
3 Quick start.
Adding your Nano Dimmer to a Z-Wave
network.
After your Nano Dimmer is installed and powered
on, you are now able to manually control the Nano
15
Dimmer to turn it On/Off/Dim directly via pressing
your Nano Dimmer’s Action Button, it is time to add
your Nano Dimmer to the Z-Wave network. To set
your Z-Wave gateway/controller into pairing mode,
please refer to the respective section within your
controller instruction manual.
1. Set your Z-Wave controller into pairing mode.
2. Press the Action Button on the Nano Dimmer or
toggle the external manual switch once, the green
LED (non-secure indication) will blink to indicate
the Nano Dimmer is entering into pairing mode.
3. If the Nano Dimmer has been successfully added
to your Z-Wave network, its RGB LED will be
solid. If the pairing was unsuccessful, the red
LED will be on for 2 seconds and then remain a
colourful gradient, repeat the instructions above
from step 1.
With your Nano Dimmer now working as a part of
your smart home, you’ll be able to configure it from
your home control software/phone application.
16
Please refer to your software’s user guide for further
instructions on configuring Nano Dimmer to your
needs.
The colour of RGB LED will change according to the
output load power level:
Version
LED indication
Output (W)
Green
[0W, 48W)
Yellow
[48W, 96W)
Red
[96W, 144W)
AU
Green
Yellow
[0W, 92W)
[92W, 184W)
Red
[184W, 276W)
EU
Green
Yellow
[0W, 92W)
[92W, 184W)
Red
[184W, 276W)
US
4 Removing Nano Dimmer from a
Z-Wave network.
17
FCC Part 15.19 Warning Statement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
FCC Part 15.21 Warning Statement
NOTE:
THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR
MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR
COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
FCC Part 15.105 Warning Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC's RF exposure guidelines, this equipment should be
installed and operated with a minimum distance of 20cm between the radiator and your body.
The antenna(s) used for this transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
This device complies with FCC Standard RF radiation exposure limits set forth for an
uncontrolled environment

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Create Date                     : 2016:12:06 15:50:03+08:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2016:12:27 17:32:10+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2016:12:27 17:32:10+08:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:1d049f6c-15b9-4830-bf36-899b668f0200
Original Document ID            : xmp.did:94D3F17082EDE41196219270117F2D13
Document ID                     : xmp.id:EAD2E28F88BBE611831BA2B5A76E66BA
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:E9D2E28F88BBE611831BA2B5A76E66BA
Derived From Document ID        : xmp.did:740CFD5AC1B2E61184C1F575951AF550
Derived From Original Document ID: xmp.did:94D3F17082EDE41196219270117F2D13
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:12:06 15:50:03+08:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 18
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBAFT111

Navigation menu