Aeon Labs ZW078 HEAVY DUTY SMART SWITCH GEN5 User Manual 501001000001 Heavy Duty Smart Switch AL001 AA 1
Aeon Labs LLC. HEAVY DUTY SMART SWITCH GEN5 501001000001 Heavy Duty Smart Switch AL001 AA 1
User Manual
Your Heavy Duty Smart Switch Important: A licensed electrician with knowledge and understanding electrician systems and electrical safety should complete the electrical installation. Status LED Heavy Duty Smart Switch Gen5 3. Preparing the wires you will be attaching to your Heavy Duty Smart Switch by stripping the wires to the necessary length. Add wire terminals to each wire. The wires please use the minimum AWG10 #, or AWG8#. Action Button Wire terminals View the digital manual: http://aeot.ec/spprt/heavyduty Action button: Used for Heavy Duty Smart Switch’s ZWave network inclusion and exclusion and to manually turn on/off; 4. Wire according to the following diagram, as shown in the figure, connect each live lines(L1,L2) from Air Break Switch to corresponding terminals that marked L1 and L2 on the Heavy Duty Smart Switch, if there is Neutral line and ‘GND’, please connect to the terminals which market ‘GND’ and ‘N’ on Heavy Duty Smart Switch, similarly wire the electric load with Heavy Duty Smart Switch. Then tighten screws to the wire terminals. Adding/Including/Pairing your Heavy Duty Smart Switch into a Z-Wave Network To add your Heavy Duty Smart Switch to your Z-Wave network with a Z-Stick, bring your Z-Stick near your Heavy Duty Smart Switch then press the button on the ZStick to begin the Z-Wave inclusion process. When your Heavy Duty Smart Switch is first powered on and it’s not a part of a Z-Wave network, its Status LED will blink. If it’s not blinking see the tip below. Press your switch’s Action button to connect it to the Z-Stick. If it’s successfully added to the network its Status LED will stop blinking or pulse steadily. If this fails, repeat the above steps. Tip: If the Status LED of your Heavy Duty Smart Switch does not blink when it’s first powered up, it means that your switch is already part of another Z-Wave network. To rectify this, first follow the subsequent Removing instructions before following the Adding/Including/Pairing steps above. Important: You must make sure the wire terminals connected firmly with each corresponding terminals on the Heavy Duty Smart Switch. Action Button Status LED: Indicates the switch’s status; Terminals: There are two groups of terminals. As marked of the silk print, AC Power be connected to main power, Load for electric load. N L2 Load L1 GND GND L2 Acpower L1 N Installation Important : Heavy Duty Smart Switch MUST wired behind an air break switch for safety and electric appliance protection . Before wiring, you must switch off the Air Break Switch and confirm the circuit power is down, if the Air Break Switch is out of sight, please lock it to ‘OFF’ position and tag it to prevent unexpected application of power: 1. Mount Heavy Duty Smart Switch on a wall as shown in following figure: Package Contents Heavy Duty Smart Switch .... ............... ...... 8AWG Wire terminal ................................ 10AWG Wire terminal .............................. Screws ................................................... Load Air Break Switch OR 5. Power on your Heavy Duty Smart Switch. At this stage you need to add it to your Z-Wave network. For instructions on how to do this, please refer to the following “Z- Wave Network Instructions” section. To add your Heavy Duty Smart Switch to your Z-Wave network with a Minimote, bring your Minimote to be within range of your Heavy Duty Smart Switch then press the remote button labelled “Include” on the Aeon Labs Minimote to begin the Z-Wave inclusion process. 6. Once added to your Z-Wave network, replace your Heavy Duty Smart Switch’s shell, and refasten to the shell. Your installation is now complete. x1 x8 x8 x2 Instruction Manual.................................... x1 Include Aeotec by Aeon Labs Heavy Duty Smart Switch Aeotec by Aeon Labs’ Heavy Duty Smart Switch is a Z-Wave switch controller that can also report the wattage energy usage and KWH usage of the device wired in to it. As part of its switching functionality, Heavy Duty Smart Switch can be controlled by other Z-Wave devices to turn loads on or off. It can bear up to 40 amps current of resister loads. It also act as a repeater, forwarding Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node. By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified device. 2. Loosen your switch’s lower screw to release its shell. Remove the shell to reveal the inner electronics. Z-Wave Network Instructions Heavy Duty Smart Switch must be paired(included) into a Z-Wave network before it can receive Z-Wave commands to turn on/off and report its energy usage. The Heavy Duty Smart Switch can only communicate to devices within its own Z-Wave network. Note: The LED on the Heavy Duty Smart Switch will blink if it is currently not operating within a Z-Wave network. Tip: Before including / excluding Heavy Duty Smart Switch from your Z-Wave network, it’s recommended that you turn off most of the appliances connected to it. This will help to prevent load damage. When your Heavy Duty Smart Switch is first powered on and it’s not a part of a Z-Wave network, its Status LED will blink. If it’s not blinking see the tip below. Press your switch’s Action button to connect it to the Z-Stick. If it’s successfully added to the network its Status LED will stop blinking or pulse steadily. If this fails, repeat the above steps. Tip: If the Status LED of your Heavy Duty Smart Switch does not blink when it’s first powered up, it means that your switch is already part of another Z-Wave network. To rectify this, first follow the subsequent Removing instructions before following the Adding/Including/Pairing steps above. To include the Aeon Labs Heavy Duty Smart Switch with other controllers, please consult the operation manual for these controllers on how to include Z-Wave products into an existing network. Removing your Heavy Duty Smart Switch From a Z-Wave Network You can remove your Heavy Duty Smart Switch from your Z-Wave network at any time. To do this you need use your main controller such as a Z-Stick or Minimote. If you are using a Z-Stick: If your Z-Stick is plugged into a gateway or a computer, unplug it. 1. Bring your Z-Stick near your Heavy Duty Smart Switch. 2. Press the Action Button on your Z-Stick. 3. Press the Action Button on your Heavy Duty Smart Switch. 4. I f y o u r H e a v y D u t y S m a r t S w i t c h h a s b e e n successfully removed from your network, its light will blink. If the removal was unsuccessful its light will not blink. 5. Press the Action Button on the Z-Stick to make it out of removal mode. If you are using a minimote: 1. Bring your Minimote near your Heavy Duty Smart Switch. 2. Press the Remove Button on your Minimote. 3. Press the Action Button on your Heavy Duty Smart Switch. 4. I f y o u r H e a v y D u t y S m a r t S w i t c h h a s b e e n successfully removed from your network, its light will blink. If the removal was unsuccessful its light will not blink. 5. Press any button on your Minimote to make it out of removing mode. Turn Your Heavy Duty Smart Switch On or Off Your Heavy Duty Smart Switch can be turned on or off through the use of Z-Wave commands built into Z- Wave certified controllers and gateways. The specific Z-Wave commands supporting this function are the Basic Command Class and Binary Switch Command Class. Please consult the operation manual for these controllers for specific instructions on controlling your Heavy Duty Smart Switch. Monitoring Power Consumption Your Aeon Labs Heavy Duty Smart Switch can report Watts energy usage or KWh energy usage to a Z-Wave gateway or controller. If this function is supported by the gateway/controller, the energy consumption will be displayed in its user interface. The specific Z-Wave commands supporting energy monitoring are the Meter Command Class and Multilevel Sensor Command Class. Automatic reports go to the only association group 1, which is setup via the Association Command Class. Please also consult the operation manual for these gateways/controllers for specific instructions on monitoring your Heavy Duty Smart Switch. Technical Specifications Model number: DSC10-ZWUS Waterproof: IP44 Power Consumption: 1W Ratings: 240VAC,50/60Hz(2Phases L1,L2) ; Maxim 9600 Watts 40A Resister; 240VAC 5HP AC Motor; RF range: 300ft/100m outdoor; Endurance of 10ms period peak current of 1440A Warranty Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as defined below), the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer. Warranty claims must be made by Customer in writing within thirty (30) days of the manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the purchase price to Customer. The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under Aeon Labs' RMA policy. Any repairs conducted by unauthorized persons shall void this warranty. Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse, misapplication, storage damage, negligence, electrical power problems, or modification to the Products or its components. Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein. Aeon Labs will pass on to Customer all manufacturers' Material warranties to the extent that they are transferable, but will not independently warrant any Material. Customer must prepay shipping and transportation charges for returned Products, and insure the shipment or accept the risk of loss or damage during such shipment and transportation. Aeon Labs will ship the repaired or replacement products to Customer freight prepaid. Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' affiliates, shareholders, directors, officers, employees, contractors, agents and other representatives harmless from all demands, claims, actions, causes of action, proceedings, suits, assessments, losses, damages, liabilities, settlements, judgments, fines, penalties, interest, costs and expenses (including fees and disbursements of counsel) of every kind (i) based upon personal injury or death or injury to property to the extent any of the foregoing is proximately caused either by a defective product (including strict liability in tort) or by the negligent or willful acts or omissions of Customer or its officers, employees, subcontractors or agents, and/or (ii) arising from or relating to any actual or alleged infringement or misappropriation of any patent, trademark, mask work, copyright, trade secret or any actual or alleged violation of any other intellectual property rights arising from or in connection with the products, except to the extent that such infringement exists as a result of Aeon Labs' manufacturing processes. IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, OR TORT, O R O T H E RW I S E E V E N I F A D V I S E D O F T H E POSSIBILITY OF SUCH DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER B A S E D O N N E G L I G E N C E , S T R I C T L I A B I L I T Y, BREACH OF WARRANTY, BREACH OF AGREEMENT, O R E Q U I TA B L E P R I N C I P L E S , I S E X P R E S S LY L I M I T E D T O , AT A E O N L A B S ' O P T I O N , REPLACEMENT OF, OR REPAYMENT OF THE P U R C H A S E P R I C E F O R T H AT P O R T I O N O F PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY. THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER I N D E M N I T I E S O R WA R R A N T I E S , W H E T H E R EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. FCCNOTICE (for USA) THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY U N A U T H O R I Z E D M O D I F I C AT I O N S T O T H I S EQUIPMENT. SUCH MODIFICATIONS COULD VOID T H E U S E R ' S A U T H O R I T Y TO O P E R AT E T H E EQUIPMENT. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consul the dealer or an experienced radio/TV technician for help. Warning Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. Certifications (regional) Version:501001000001-AA www.aeotec.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Administrator Title : 501001000001 Heavy Duty Smart Switch_AL001 AA-1 Create Date : 2014:02:11 14:26:03+08:00 Creator Tool : CorelDRAW Modify Date : 2014:04:28 11:32:28+08:00 Metadata Date : 2014:04:28 11:32:28+08:00 Producer : Corel PDF Engine Version 14.0.0.701 Document ID : uuid:06f1cca8-d2eb-4cbf-91c6-c1c5e7d31d7d Instance ID : uuid:0fae35b1-59c8-42d4-b31c-5c30df1ead6f Page Count : 2 Author : AdministratorEXIF Metadata provided by EXIF.tools