Agrident AIR200 Proximity Reader User Manual AIRacc db e

AGRIDENT GmbH Proximity Reader AIRacc db e

Contents

User Manual 2

Download: Agrident AIR200 Proximity Reader User Manual AIRacc db e
Mirror Download [FCC.gov]Agrident AIR200 Proximity Reader User Manual AIRacc db e
Document ID681696
Application IDtf2nz+KRFbe/IdCBSXL2Pg==
Document DescriptionUser Manual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.67kB (458428 bits)
Date Submitted2006-07-17 00:00:00
Date Available2006-07-17 00:00:00
Creation Date2006-07-10 14:10:49
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2006-07-10 14:10:49
Document TitleMicrosoft Word - AIRacc db_e.doc
Document CreatorPScript5.dll Version 5.2
Document Author: busche

Agrident GmbH, Steinklippenstr. 10, D-30890 Barsinghausen
Phone +49 5105 520614 - Fax +49 5105 520616
AIR200
Installation
V10/07/06
AIR200
Installation
© Copyright 2006 by Agrident GmbH
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise, without prior written permission of Agrident GmbH.
Agrident reserves the right to make changes to any and all parts of this documentation without
obligation to notify any person or entity of such changes.
July 2006 BB/JK
Agrident GmbH
Steinklippenstr. 10
30890 Barsinghausen
Germany
Phone +49 51 05 520614
Fax +49 51 05 520616
E-Mail: mail@agrident.com
www.agrident.com
10.07.06
Page 2 of 11
AIR200
Installation
Contents
1.
Introduction.......................................................................................................... 4
2.
Specification ........................................................................................................ 4
3.
Installation ........................................................................................................... 4
3.1
Installation of the AIR200 reader .................................................................. 4
3.2
Installation of the AEA080 antenna .............................................................. 8
4.
Safety and care ................................................................................................... 9
5.
Warranty.............................................................................................................. 9
6.
FCC digital device limitations ............................................................................ 10
7.
CANADIAN RADIO EMISSIONS REQUIREMENTS ......................................... 10
8.
CE MARKING.................................................................................................... 10
10.07.06
Page 3 of 11
AIR200
Installation
1. Introduction
The ISO reader module AIR200 is designed as an integrated reader head for the handheld
computer Workabout PRO M/C by PSION TEKLOGIX. It combines the reading of ISO
transponders with the Windows CE software of the PSION®-workabout PRO. Together with the
external antenna AEA080 from Agrident, the reading of bolus or ear tags is much more
convenient. The AIR200 is compatible to ISO 11784/5. It reads HDX and FDX-B transponders
also as H4002 compatible transponders.
To install the AIR200 module in a Workabout PRO handheld, please follow the instructions
below.
2. Specification
Module:
Interface:
Coverage transponder:
Reading distance:
Dimension:
Weight:
Handheld:
External Antenna:
AIR200
AAB10 adapter board
HDX, FDX-B (ISO 11784/5), H4002
up to 150 mm with FDX-B transponder Ø 30 mm
up to 200 mm with HDX transponder Ø 30 mm
190 x 100 x 35 mm
appr. 140 g
PSION TEKLOGIX Workabout PRO M/C only
Agrident AEA080
3. Installation
3.1
Installation of the AIR200 reader
1.
TheAIR 200 mounting set consists of 2 screws
with washer and an adapter board with 4
screws.
10.07.06
2.
Remove the pen.
Page 4 of 11
AIR200
Installation
3.
Pull out the 4 screws on top
4.
5.
Push the SW1401 switch in position OFF.
6.
Remove the cover from the battery room by
unlocking the screws.
7.
Remove the battery.
8.
Put in the adapter board as shown above.
10.07.06
and the 6 screws on the back.
Page 5 of 11
AIR200
Installation
9.
10.
Fix the adapter board with the 4 added screws. Push the SW1401 switch in position ON,
again.
11.
12.
Now stick the AIR 200 reader to the Workabout and fix it with the 2 added washers and
PRO, as shown
screws.
13.
Fix the 4 screws on top.
10.07.06
14.
Mount the back plate with the 6 screws.
Page 6 of 11
AIR200
Installation
15.
Put in the battery and close the battery room
16.
by bolting the cover with the screws.
17.
Push the pen back in its holder.
18.
Keep the Workabout's head cover, in case that
you might need it.
Please follow the instructions of the protocol,
before you start a read.
10.07.06
Page 7 of 11
AIR200
3.2
Installation
Installation of the AEA080 antenna
1.
The stick antenna AEA080 can easily be fixed
to the reader by a so called Binder plug.
2.
Screw the silver cap off from the socket.
3.
Put the Binder plug of the stick antenna in the
socket of the AIR200 reader.
4.
Pay attention to the groove.
5.
Follow the instructions of your Workabout PRO,
to start a read.
10.07.06
Page 8 of 11
AIR200
Installation
4. Safety and care
The manufacturer accepts no liability for damage resulting from improper use or use not
consistent with that described in these operating instructions.
• The AIR accessories contain no parts that can be repaired by the user. For this reason it
may only be repaired by authorised customer service personnel.
• In both operation and storage of the antenna please secure to comply with the environment
conditions specified in the technical data.
• Clean the AIR accessories only with a damp cloth. Use only water and any commercially
available cleaning agent.
Any modification to the AIR accessories will render the warranty null and void.
5. Warranty
The manufacturer of the AIR accessories will provide a warranty of
12 months
from the day the device is shipped and subject to the following conditions:
a. Without submission of proof of purchase no warranty can be given.
b. In the event that defects are detected the manufacturer is entitled to choose between up to
two attempts at repair or supplying a replacement device on one occasion. The warranty
period for the repaired item or for a replacement item is 3 months but will always extend to
the end of the original warranty period. No further claims can be entertained, especially
claims for compensation for consequential losses. This exclusion of liability does not apply to
claims made on the basis of the Product Liability Act.
c. Warranty claims cannot be entertained unless the Agrident system was installed properly
and used properly and for the purpose intended.
No warranty obligations exist in particular when:
1. Damage is attributable to improper use of the device, to a incorrect connection or incorrect
operator action;
2. The device was not cared for and maintained in accordance with the manufacturer's
recommendations and this is the cause of the damage;
3. The damage is due to any modification to the device;
4. The damage is due to force majeure, for example, lightning strike;
5. The damage is due to wear resulting from overstressing mechanical parts.
10.07.06
Page 9 of 11
AIR200
Installation
6. FCC digital device limitations
Radio and Television Interference
This equipment has been tested and found to comply with the limits for a digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case the user will be required to correct the interference
at his own expense.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
In order to maintain compliance with FCC regulations, shielded cables must be used with this
equipment. Operation with non-approved equipment or unshielded cables is likely to result in
interference to radio and television reception.
Caution! Changes or modifications not expressly approved by the manufacturer could void the
user’s authority to operate this equipment.
7. CANADIAN RADIO EMISSIONS REQUIREMENTS
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites
applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le
brouillage radioelectrique edicte par le ministere des Communications du Canada.
Industry Canada:
Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
This device has been designed to operate with the antennas listed below, and having a
maximum gain of 1.8 dB. Antennas not included in this list or having a gain greater than 1.8 dB
are strictly prohibited for use with this device. The required antenna impedance is 2.8 ohms.
- Stick Antenna AEA080
- Stick Antenna AEA120
To reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted
for successful communication.
8. CE MARKING
Hereby, Agrident BV declares that this equipment, if used according to the instructions, is in
compliance with the essential requirements and other relevant provisions of the RTTE Directive
1999/5/EC. For use in all countries of the EU.
10.07.06
Page 10 of 11
AIR200
Installation
To obtain a copy, contact Agrident BV and request the “Declaration of Conformity” document for
Multi-technology readers.
Agrident BV
mail@agrident.com
In case of alteration of the product, not agreed to by us, this declaration will lose its validity.
This symbol indicates proof of conformity to applicable European
Economic Community Council directives and harmonized standards
published in the official journal of the European Communities.
10.07.06
Page 11 of 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2006:07:10 14:10:49+02:00
Modify Date                     : 2006:07:10 14:10:49+02:00
Page Count                      : 11
Creation Date                   : 2006:07:10 12:10:49Z
Mod Date                        : 2006:07:10 12:10:49Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : busche
Metadata Date                   : 2006:07:10 12:10:49Z
Creator                         : busche
Title                           : Microsoft Word - AIRacc db_e.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QG2AIR200

Navigation menu