RY-ES
External Signaling Relay
- INSTALLATION & OPERATION INSTRUCTIONS The RY-ES is a relay used to activate an external signaling device when the door station calls in. It can be
used for call extension on the JP, JO, JK, JF, KB, AX, NIM, DB, and IE systems (excluding IE-8MD). The
relay connects to the chime output of the master station in place of the IER-2. The RY-ES relay will share
power with the master station.

1 NAMES & FUNCTIONS
Input of relay:
Red: Positive Power
Black: Negative Power
White: Activation wire
Blue: Activation wire

RY-ES

Output of relay:
2 Orange wires
N/O Dry contact closure

2 INSTALLATION
RY-ES

Mounting
bracket (2)

Wall mount the unit with the
supplied mounting hardware as
shown in the diagram to the left.
When making wire connections,
be sure not to short any wires
together. Use wire nuts or
another protective material to
isolate the connections.

Wood screw (2)
Screw (2)

RY-ES Instructions
Pg. 1

3 WIRING DIAGRAMS
JP System
JP-4MED
1A1

M(OUT)

1A2
2A1
2A2
3A1
3A2
4A1
4A2

+
-

Blue
White
Red
Black

S
S

A1
A2

A1
A2

DOOR

JO-1FD
Expansion Station
MASTER
STATION

Door

CALL EXT

L1
L1
L2
L2

JO System

PS-2420UL

+
-

CALL EXT

L
L

Orange

A1
A2

PS-1820UL
+
-

+
L
L

S
S

S
S
Blue
White
Red
Black

!
!

External Device
and Power

JO-1MD
Master Station

B1
B2

+
-

RY-ES

CALL EXT

A1
A2

DOOR

Door

Connect the RY-ES relay to either the JO-1MD master station or
the JO-1FD expansion station. Do not connect the same relay to
both stations.

RY-ES

Orange

External Device
and Power

JK & JF Systems

A1
A2

SUB OUT

A1
A2

JK-1MD/JK-1MED, JF-2MED
DOOR

Door

B1
B2

L
L

RY-ES Instructions
Pg. 2

CALL EXT

+
-

S
S

PS-1820UL
+
-

Blue
White
Red
Black

RY-ES

Orange

External Device
and Power

3 WIRING DIAGRAMS (cont)
KB System

KB-3MRD

Door

1A1
1A2

A1
A2

B1
B2
+
-

S
S

PS-2420UL
+
-

Blue
White
Red
Black

RY-ES

Orange

External Device
and Power

AX System
AX-DV

Cat5e

PS-2420UL
+

AX-8M/AX-8MV

Cat5e
PS-2420UL
+

Black
Red
White
Blue

RY-ES

Orange

External Device
and Power

RY-ES Instructions
Pg. 3

3 WIRING DIAGRAMS (cont)
NIM System
NI-BA
A
M
E
IS-PU-UL
+
-

NIM-20B
1
~
10
M
E
S1
S1
+
-

Connect the red and black wires of RY-ES to the M and E terminals of the NIM master
to power the relay. Do NOT connect to + and - of the NIM master.

Red
Black

RY-ES

White

External Device
and Power

Orange

Blue

DB System

IE System

DA-1DS

DB-1MD

D
E
L
L

D
E
B1
B2
B3
B4
BL+
BL15V

~

Org
Yel

~

PT-1211C

IE-1GD / IE-2AD

1
2

D1
E1
(D2)
(E2)
T
R
C
E

White
Blue
Red
Black

RY-ES

Orange

~
~
External Device
and Power

~ ~

IE Door

PT-1210N

+
-

White
Blue
Red
Black

RY-ES

Orange

External Device
and Power

The RY-ES will work with the IE-1GD, IE-2AD, and IE-1AD.
Connections for the IE-1GD and IE-2AD are shown above.
When using the IE-1AD, connect the white/blue wires of the
RY-ES to the white leads of the unit.
The RY-ES is NOT compatible with the IE-8MD.

4 SPECIFICATIONS
Power Source: 			
12-30V DC, 12-16V AC. Power supplied by master.
Current consumption:		
DC: Standby 10mA. Max 60mA
					
AC: Standby 15mA. Max 70mA
Contact rating:			
125V AC 1.0A
					30V DC 1.0A
Aiphone Corporation
www.aiphone.com
tech@aiphone.com
(800) 692-0200

RY-ES Instructions
Pg. 4
0316JD



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Instance ID                     : uuid:513c78ca-5d90-4f1e-be38-3533effa5efd
Original Document ID            : adobe:docid:indd:aacd6357-fba6-11de-9972-93d40c9f038d
Document ID                     : xmp.id:b416e51f-ae49-4248-9dfc-87e7a8130aa4
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:2aa3d38d-2abc-4d4c-8e3f-6aca70aad1b2
Derived From Document ID        : xmp.did:294B6132CDD0DF11ADFA9B061416B1F1
Derived From Original Document ID: adobe:docid:indd:aacd6357-fba6-11de-9972-93d40c9f038d
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:06:10 11:10:40-07:00
Create Date                     : 2016:06:10 11:10:40-07:00
Modify Date                     : 2016:06:10 11:10:41-07:00
Metadata Date                   : 2016:06:10 11:10:41-07:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu