AirWalk Communications AW96R19AF7 AW96R19AF7 MiniCell User Manual System Installation Manual

AirWalk Communications, Inc. AW96R19AF7 MiniCell System Installation Manual

System Installation Manual

___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 1 of 56  6/14/2006      Installation & Maintenance Manual -  AW-96 Mini-Cell -  AW 10 Pilot Beacon  Version # 1.2  June 2006   Prepared By AirWalk Communications, Inc. 1830 North Greenville Ave Richardson, TX, 75081 Phone: (972) 638-9400 Fax: (972) 638-9401 www.airwalkcom.com  FOR USE BY TRAINED TECHNICIANS ONLY
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 2 of 56  6/14/2006  Revision History Version  Date  Person  Description 0.1 10/15/2005 CMO Draft Document 1.0 11/23/2005 CMO Released 1.1 4/30/2006 CMO Pictures corrected 1.2  6/14/2006  CMO  Added regulatory compliance information                                                 Revision Numbering Key 0.x   Work in Progress 1.0   Initial Document Approval 1.x   Revisions Following Initial Document Approval 2.0   Revisions Approval
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 3 of 56  6/14/2006 Table of Contents TABLE OF CONTENTS..................................................................................................................................3 1 INTRODUCTION.....................................................................................................................................5 1.1 PROPRIETARY INFORMATION NOTICE ..................................................................................................5 1.2 PURPOSE OF DOCUMENT ......................................................................................................................5 1.3 SCOPE ..................................................................................................................................................5 1.4 ORDER OF PRECEDENCE.......................................................................................................................5 1.5 TERMINOLOGY.....................................................................................................................................5 1.6 APPLICABLE DOCUMENTS ...........................................................................................................5 1.6.1 AirWalk Documents.....................................................................................................................5 1.6.2 Telecom Standards......................................................................................................................6 1.6.3 Other Documents.........................................................................................................................6 2 AW-96 MINICELL / AW-10 PILOT BEACON MODEL STRUCTURE...........................................7 2.1 1900 MHZ CONFIGURATIONS (PCS BAND)..........................................................................................7 2.2 800 MHZ CONFIGURATIONS ................................................................................................................8 2.3 450 MHZ (NMT BAND) CONFIGURATIONS..........................................................................................9 3 AW 96 & AW 10 SAFETY AND COMPLIANCE INFORMATION ................................................10 3.1 STATEMENT OF INTENT .....................................................................................................................10 3.2 SAFETY PRECAUTIONS .......................................................................................................................10 3.3 MAINTENANCE INFORMATION ...........................................................................................................11 3.3.1 Cleaning ....................................................................................................................................11 3.3.2 Filter Maintenance....................................................................................................................11 3.3.3 Fuse Replacement .....................................................................................................................11 3.3.4 Other Maintenance....................................................................................................................11 3.4 LABELING ..........................................................................................................................................12 3.4.1 Grounding .................................................................................................................................12 3.4.2 Label: Model Identification, FCC Identification, Power ..........................................................12 3.5 REGULATORY COMPLIANCE INFORMATION .......................................................................................13 3.5.1 Radio Interference (FCC 15.19 Statement)...............................................................................13 3.5.2 Unauthorized Modifications (FCC 15.21 Statement)................................................................13 3.5.3 Digital Device Interference (FCC 15.105 Statement)...............................................................13 3.5.4 RF Exposure (FCC MPC Compliance).....................................................................................13 4 AW 96 / AW 10 SYSTEM INTRODUCTION......................................................................................14 4.1 OVERVIEW .........................................................................................................................................14 4.2 IP- BASE STATION (BS) SYSTEM DESCRIPTION .................................................................................14 4.3 HARDWARE CONFIGURATION ............................................................................................................15 4.3.1 Physical Description .................................................................................................................15 4.3.2 Typical Configurations..............................................................................................................15 4.3.3 Installation Photographs...........................................................................................................16 4.4 BLOCK DIAGRAM – AW 96 MINICELL / AW 10 PILOT BEACON ........................................................17 4.5 SYSTEM CAPACITIES AND SPECIFICATIONS........................................................................................18 4.5.1 AW 96 Technical Specification..................................................................................................18 4.5.2 IP-BS Power Supply & Environment Technical Specification ..................................................19 5 AW 96 MINICELL / AW 10 PILOT BEACON COMPONENTS......................................................20
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 4 of 56  6/14/2006 5.1 AW-96 / AW 10 MAIN UNIT..............................................................................................................20 5.2 COMPONENT LED CONFIGURATION ..................................................................................................22 6 AW 96 / AW 10 INTERFACE CABLING............................................................................................24 6.1 RF CABLING – AW 96 MINICELL ......................................................................................................24 6.2 RF CABLING – AW 10 PILOT BEACON...............................................................................................24 6.3 ETHERNET/SERIAL CABLE WIRING (AW 96 / AW 10) .......................................................................25 6.4 ELECTRIC POWER CABLE WIRING (AW 96 / AW 10).........................................................................25 6.5 PHOTOGRAPH OF TYPICAL CABLE WIRING........................................................................................26 7 FREQUENCY SETTING PROCEDURES ..........................................................................................27 7.1 BSM MANAGEMENT..........................................................................................................................27 7.2 LOCAL FA SETTING ...........................................................................................................................27 7.2.1 MMI Connection .......................................................................................................................27 7.2.2 FA Change Procedure...............................................................................................................28 8 INSTALLATION PROCEDURES........................................................................................................30 8.1 INSTALLATION VERIFICATION............................................................................................................30 8.1.1 Verify Customer Contact & Equipment location.......................................................................30 8.1.2 Uncrate and arrange for packing material disposal.................................................................31 8.1.3 Verify location of all Facility distribution points  (main and intermediate)..............................31 8.2 AW-SERIES IP-RAN INSTALL PROCEDURES ...................................................................................32 8.2.1 Install AW-SERIES IP-RAN Cabinet.........................................................................................32 8.2.2 Verify All Internal System Connections.....................................................................................32 8.2.3 External System Connections ....................................................................................................33 8.2.4 Connect Power to Cabinet ........................................................................................................33 8.2.5 Connect Communications Facilities..........................................................................................33 8.2.6 Power-up procedure..................................................................................................................34 8.3 SYSTEM TEST.....................................................................................................................................34 8.3.1 PC to AW 96 cable ....................................................................................................................34 8.3.2 System Certification Tests .........................................................................................................35 8.3.3 Operation Tests .........................................................................................................................40 8.3.4 Operator Specific Tests .............................................................................................................41 8.4 SITE CLEAN UP AND CUSTOMER SIGNOFF ..........................................................................................41 8.4.1 Dispose of all packing material.................................................................................................41 8.4.2 Clean-up site. ............................................................................................................................41 8.4.3 Update Installation Checklist....................................................................................................41 8.4.4 Customer Signoff.......................................................................................................................41 8.5 REQUIRED TOOLS AND SUPPLIES .......................................................................................................41 8.6 TROUBLESHOOTING PROCEDURES .....................................................................................................42 8.6.1 Before Calling for Assistance....................................................................................................42 8.6.2 When Calling for Assistance .....................................................................................................43 9 APPENDIX A - ACRONYMS................................................................................................................44 10 APPENDIX B - SITE PREPARATION CHECKLIST ...................................................................49 11 APPENDIX C - INSTALLATION CHECKLIST............................................................................52 12 APPENDIX D - CUSTOMER CERTIFICATION DOCUMENT..................................................55
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 5 of 56  6/14/2006 1 INTRODUCTION 1.1  Proprietary Information Notice THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC. 1.2  Purpose of Document The purpose of this document is to define the Installation, Maintenance and Safety Compliance of AirWalk Communication’s, Inc. unique CDMA Radio Access Network (RAN) system. The AirWalk RAN is a market ready, standards compliant, high channel capacity, cost effective, modular and expandable wireless radio access network system. Designed specifically for CDMA2000 networks, the Base Station Transceiver (BTS) and Base Station Controller (BSC) are integrated into a single compact platform. The target market and applications are in-building areas, corporations, corporate campuses, enterprises, university campuses, large industrial plants, stadiums, airports, shopping malls, blind spots, hot spots, rural areas, neighborhoods, and highways. 1.3 Scope The scope of this document covers the description, environmental specifications, equipment location, cabling, system installation and maintenance of the AirWalk RAN. Specific models covered are identified in the section entitled “Model Information”. 1.4  Order of Precedence This System Installation Manual will take precedence over any previous AirWalk System Installation Manual or Document. 1.5 Terminology See the section entitled: Appendix A - Acronyms 1.6 APPLICABLE DOCUMENTS The following documents are applicable to the extent specified in this System Installation Manual. 1.6.1 AirWalk Documents •  IP- Base Station (BS) System Description. •  IP- Base Station (BS) CPIB Block Diagram. •  IP- Base Station (BS) GPSR Block Diagram. •  IP- Base Station (BS) PCPM Block Diagram. •  IP- Base Station (BS) XCVB Block Diagram. •  AirWalk System Specification-11-13-2003-v1.0.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 6 of 56  6/14/2006 • System User Manual_022404. •  System Installation Manual_030104. 1.6.2 Telecom Standards •  TIA/EIA/IS-2000 Series Revision: C - Introduction to CDMA2000 Spread Spectrum Systems, 05/00/02 •  Personal Station – Base Station Compatibility Requirements for1.8 to 2.0 GHz CDMA PCS. •  TIA/EIA-664 - Wireless Features Description, 12/00/00   •  TIA/EIA Interim Standard 95 Revision A - Mobile Station –Base Station Compatibility Standard for Dual-Mode Wideband Spread Spectrum Cellular Systems, May 1995 •  TIA/EIA-95-B - Mobile Station-Base Station Compatibility Standard for Dual-Mode Spread Spectrum Systems, October 31, 1998 •  MSC to BS Interface Inter-Operability Specification (IOS) IOS-4.2 •  IMT-2000 Specification, (indoor wireless propagation) 1.6.3 Other Documents None Identified
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 7 of 56  6/14/2006 2  AW-96 MiniCell / AW-10 Pilot Beacon Model Structure 2.1  1900 MHz Configurations (PCS Band) This model chart covers all 1900 MHz (PCS band) configuration models. Not all models are available in all markets. Clarify any model structure questions with Technical Support Services or your Sales representative. GroupAssembly  Part Number Name DescripionSUB0031 CDPB CPIB & PCPM 96 CE 1 1 1 1 1 1 1 1 1 (Alt)SUB00xx CDPB CPIB & PCPM 32 CE (obsolete) 1SUB00xx CDPB CPIB & PCPM PB Only 1PBA0004 XCVB1.9 GHz Dual Mode 1/50mW PCS 1111133333(Alt)PBA0003 XCVB 800 Dual Mode 1/50mW Cell BandPBA0006 XCVB 450 Dual Mode 1/50mW NMT (A/H)SUB0004 XCVB 2100 MHz 1mW (Japan Band)SUB00xx XCVB 1800 MHz 1mW (Korea Band)SUB00xx XCVB 1.9 GHz xmit ONLY (PB) 1SUB00xx XCVB 800 MHz Xmit ONLY (PB)SUB00xx RCPB 5.0 Watt Internal PA Module 1.9 MHz 1 1SUB00xx RCPB 5.0 Watt Internal PA Module 800 MHzSUB00xx FEDB MiniCell Internal Duplexer 1.9 GHz 1SUB00xx FEDB MiniCell Internal Duplexer 800 MHzSUB00xx Chassis AW-96 Chassis - Onmi Internal PA 1SUB00xx Chassis AW-96 Chassis - Onmi/1S 1 1 1 1SUB00xx Chassis AW-96 Chassis - 2 SectorSUB00xx Chassis AW-96 Chassis - 3 sector 1 1 1 1 1SUB00xx Chassis AW-10 Chassis - Pilot Beacon 1CBK0005 Ext Cable External Cable Kit - Omni RU 1 1CBK0006 Ext Cable External Cable Kit - Sector RU - S1 1 1 1 1CBK0007 Ext Cable External Cable Kit - Sector RU - S2 1 1 1 1CBK0008 Ext Cable External Cable Kit - Sector RU - S3 1 1 1 1Cord SUB00xx Pwr CordPower Cord UL 16 Guage 11111111111SUB00xx RU Omni System - 1900 Band C/F 1SUB00xx RU Omni System - 1900 Band A/B/D/E 1SUB0028 RU Omni System - 800SUB00xx RU Omni System - 450 NMT A Sub BandSUB00xx RU Sector System - 1900 Band C/F 1 1SUB00xx RU Sector System - 1900 Band A/B/D/E 1 1SUB0029 RU Sector System - 800SUB00xx RU Sector System - 450 NMT A Sub BndSUB00xx RU Sector System - 2100 JapanSUB00xx Cabinet AW Cabinet Package 19" Short 1 1XCVB AssyMount AssyRU AssyCDPB AssyAW96R19AA1A01AW96R19AB7A01Ext Cable KitsRCPB AssyFEDBChassis AssyHigh Level Model Structure Chart                            (AW-96 Series 1900 MHz Band Configurations)AW96C1DAJ3A01AW96R19AJ7A01AW96R19AB3A01AW96R19AJ3A01AW10R19AF1A01AW96R19AF7A01AW96R1DAJ7A01AW96R1DAJ3A01AW96C19AJ3A01
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 8 of 56  6/14/2006 2.2 800 MHz Configurations This model chart covers all 800 MHz (conventional Cellular band) configuration models. Not all models are available in all markets. Clarify any model structure questions with Technical Support Services or your Sales representative.  GroupAssembly  Part Number Name DescripionSUB0031 CDPB CPIB & PCPM 96 CE 1 1 1 1 1 1 (Alt)SUB00xx CDPB CPIB & PCPM 32 CE (obsolete) 1SUB00xx CDPB CPIB & PCPM PB Only 1PBA0004 XCVB 1.9 GHz Dual Mode 1/50mW PCSPBA0003 XCVB 800 Dual Mode 1/50mW Cell Band 1 1 1 1 3 3 3 (Alt)PBA0006 XCVB 450 Dual Mode 1/50mW NMT (A/H)XCVBSUB0004 XCVB 2100 MHz 1mW (Japan Band)SUB00xx XCVB 1800 MHz 1mW (Korea Band)SUB00xx XCVB 1.9 GHz xmit ONLY (PB)SUB00xx XCVB 800 MHz Xmit ONLY (PB) 1SUB00xx RCPB 5.0 Watt Internal PA Module 1.9 GHzSUB00xx RCPB 5.0 Watt Internal PA Module 800 GHz 1 1SUB00xx FEDB MiniCell Internal Duplexer 1.9 GHzSUB00xx FEDB MiniCell Internal Duplexer 800 MHz 1SUB00xx Chassis AW-96 Chassis - Onmi Internal PA 1SUB00xx Chassis AW-96 Chassis - Onmi/1S 1 1 1SUB00xx Chassis AW-96 Chassis - 2 SectorSUB00xx Chassis AW-96 Chassis - 3 sector 1 1 1SUB00xx Chassis AW-10 Chassis - Pilot Beacon 1CBK0005 Ext Cable External Cable Kit - Omni RU 1CBK0006 Ext Cable External Cable Kit - Sector RU - S1 1 1CBK0007 Ext Cable External Cable Kit - Sector RU - S2 1 1CBK0008 Ext Cable External Cable Kit - Sector RU - S3 1 1Cord SUB00xx Pwr Cord Power Cord UL 16 Guage 1 1 1 1 1 1 1 1SUB00xx RU Omni System - 1900 Band C/FSUB00xx RU Omni System - 1900 Band A/B/D/ESUB0028 RU Omni System - 800 1SUB00xx RU Omni System - 450 NMT A Sub-BandSUB00xx RU Sector System - 1900 Band C/FSUB00xx RU Sector System - 1900 Band A/B/D/ESUB0029 RU Sector System - 800 1 1SUB00xx RU Sector System - 450 NMT A Sub BndSUB00xx RU Sector System - 2100 JapanSUB00xx Cabinet AW Cabinet Package 19" Short 1XCVB AssyRCPB AssyChassis AssyFEDBCDPB AssyAW10R80AF1A01AW96R80AJ7A01AW96R80AB3A01AW96R80AJ3A01AW96C80AJ3A01High Level Model Structure Chart                            (AW-96 Series 800 MHz Band Configurations)AW96R80AA1A01AW96R80AB7A01AW96R80AF7A01Ext Cable KitsRU AssyMount Assy
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 9 of 56  6/14/2006 2.3  450 MHz (NMT Band) Configurations This model chart covers 450 MHz (former NMT Nordic Mobile Telephone band) configuration models. Not all models are available in all markets. Clarify any model structure questions with Technical Support Services or your Sales representative.  GroupAssembly  Part Number Name DescripionSUB0031 CDPB CPIB & PCPM 96 CE 1 1 1 1 1 1SUB00xx CDPB CPIB & PCPM 32 CE (obsolete) 1SUB00xx CDPB CPIB & PCPM PB OnlyPBA0004 XCVB 1.9 GHz Dual Mode 1/50mW PCSPBA0003 XCVB 800 Dual Mode 1/50mW Cell BandPBA0006 XCVB 450 Dual Mode 1/50mW NMT (A/H) 1 1 1 1 3 3 3SUB0004 XCVB 2100 MHz 1mW (Japan Band)SUB00xx XCVB 1800 MHz 1mW (Korea Band)SUB00xx XCVB 1.9 GHz xmit ONLY (PB)SUB00xx XCVB 800 MHz Xmit ONLY (PB)SUB00xx RCPB 5.0 Watt Internal PA Module 1.9 GHzSUB00xx RCPB 5.0 Watt Internal PA Module 800 GHzSUB00xx FEDB MiniCell Internal Duplexer 1.9 GHzSUB00xx FEDB MiniCell Internal Duplexer 800 MHzSUB00xx Chassis AW-96 Chassis - Onmi Internal PA 1SUB00xx Chassis AW-96 Chassis - Onmi/1S 1 1 1SUB00xx Chassis AW-96 Chassis - 2 SectorSUB00xx Chassis AW-96 Chassis - 3 sector 1 1 1SUB00xx Chassis AW-10 Chassis - Pilot BeaconCBK0005 Ext Cable External Cable Kit - Omni RU 1CBK0006 Ext Cable External Cable Kit - Sector RU - S1 1 1CBK0007 Ext Cable External Cable Kit - Sector RU - S2 1 1CBK0008 Ext Cable External Cable Kit - Sector RU - S3 1 1Cord SUB00xx Pwr Cord Power Cord UL 16 Guage 1 1 1 1 1 1 1SUB00xx RU Omni System - 1900 Band C/FSUB00xx RU Omni System - 1900 Band A/B/D/ESUB0028 RU Omni System - 800SUB00xx RU Omni System - 450 NMT A Sub-Band 1SUB00xx RU Sector System - 1900 Band C/FSUB00xx RU Sector System - 1900 Band A/B/D/ESUB0029 RU Sector System - 800SUB00xx RU Sector System - 450 NMT A Sub Bnd 1 1SUB00xx RU Sector System - 2100 JapanSUB00xx Cabinet AW Cabinet Package 19" Short 1XCVB AssyHigh Level Model Structure Chart                            (AW-96 Series 450 MHz Band Configurations)AW96R45AB3A01AW96R45AJ3A01AW96C45AJ3A01AW96R45AA1A01AW96R45AB7A01AW96R45AF7A01AW96R45AJ7A01Mount AssyExt Cable KitsRCPB AssyChassis AssyRU AssyFEDBCDPB Assy
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 10 of 56  6/14/2006 3  AW 96 & AW 10 Safety And Compliance Information 3.1  Statement Of Intent The AirWalk AW 96 / AW 10 RAN is intended for use in a CDMA cellular infrastructure radio access network. The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 3.2 Safety Precautions  1) Power Sources Use only power sources that are within the specified limits as designated on the equipment labels. Use of power sources outside the specified limits is hazardous and may cause personal injury or property damage. 2) Equipment Location Equipment should be located indoors or in a suitable protected environment such as an equipment enclosure. Use of unprotected equipment outdoors is hazardous and may cause personal injury or property damage. 3) Grounding And Electrical Connections Electrical connections including equipment grounding should be made in accordance with the National Electric Code and any local regulations. Improper electrical connections are hazardous and may cause personal injury or property damage. Consult a licensed electrical installer if in doubt.  4) Hazardous Voltages Equipment may contain hazardous voltages. Only qualified service personnel should open the equipment for adjustments, repairs or replacements. 5) Replacement Parts Damaged parts and protective devices such as fuses should only be replaced by components approved or recommended by AirWalk Communications. Replacement fuses must be of the same rating and type as the original for continued protection.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 11 of 56  6/14/2006 3.3 Maintenance Information 3.3.1 Cleaning The AirWalk AW 96 / AW 10 units are protected by a high performance paint which does not require normal maintenance.  If paintwork is soiled, it can be cleaned using a damp cloth after AC power has been disconnected. Do not use liquids or spray cleaning substances on the unit since property damage or personal injury may result. 3.3.2 Filter Maintenance The AW 96 / AW 10 Main Unit is equipped with a washable air filter located in a front mounted drop down door. This filter should be checked annually for dirt build-up and cleaned if required. Note more frequent inspections may be needed in dusty environments.        3.3.3 Fuse Replacement The AW 96 Main Unit contains a 250 V 5A fuse located behind the AC connector cap as shown in the diagram. Replace the fuse with the same type and ratings.        3.3.4 Other Maintenance Any other required maintenance must be performed by suitable trained service personnel. Do not open covers or attempt to repair unit if not suitably trained. RemovableFuse CapRemovableFuse Cap Air Filter Located InDrop Down Front DoorAir Filter Located InDrop Down Front Door
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 12 of 56  6/14/2006 3.4 Labeling 3.4.1 Grounding Proper grounding is recommended to ensure good RF performance in addition to personnel safety. Antenna systems should also be suitably grounded for good RF performance.  Grounding connection points on the chassis are identified by this symbol:   3.4.2  Label: Model Identification, FCC Identification, Power The following label is applied to the AW 96 unit to provide model identification, FCC identification and rated power supply information (sample label shown).                IP-Base StationModel : AW96R19AJ1A01    FCC ID : R4HAW96R19AJ1A01S/N :76.050.0AC IN: 100-240 VAC 50/60Hz 6A/3AFuse: AC 250V 6A (20mm x 5mm)AirWalk Communications., Inc  Contact: +1-972-638-9400*ZF000096UA*Made In U.S.A.IP-Base StationModel : AW96R19AJ1A01    FCC ID : R4HAW96R19AJ1A01S/N :76.050.0AC IN: 100-240 VAC 50/60Hz 6A/3AFuse: AC 250V 6A (20mm x 5mm)AirWalk Communications., Inc  Contact: +1-972-638-9400*ZF000096UA*Made In U.S.A. 1.0 15.0
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 13 of 56  6/14/2006 3.5 Regulatory Compliance Information The FCC regulatory compliance information provided in this section is applicable only to models equipped with an FCC identification number (FCC ID). 3.5.1 Radio Interference (FCC 15.19 Statement) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3.5.2 Unauthorized Modifications (FCC 15.21 Statement) Persons or parties responsible for operation of this equipment are cautioned that any changes or modifications not expressly approved by AirWalk Communications Incorporated could void the user’s authority to operate this equipment. 3.5.3  Digital Device Interference (FCC 15.105 Statement) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 3.5.4  RF Exposure (FCC MPC Compliance) In order to comply with FCC RF Exposure requirements, this device must be installed and operated in such a way that a minimum separation distance of 20 cm is always maintained between the antenna and all persons during normal operations.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 14 of 56  6/14/2006 4    AW 96 / AW 10 System Introduction 4.1 Overview The AirWalk AW 96 MiniCell / AW 10 Pilot Beacon (CDMA-2000 IP-Base Station) product are unique in that both BTS and BSC functionality are combined in one compact platform.  This product is designed for efficiency and optimized to reduce the service providers CAPEX, and OPEX and at the same time, it increases the number of users per assigned spectrum.  It provides higher capacity in less space for today’s spectrum hungry data and multi-media applications. The AW 96 system provides the following advantages: •  Compact Omni system in a single package •  Supports 2G (TIA/EIA-95, J-STD-008) and 3G-1X (CDMA2000) standards •  Supports data service transmission of 1.2 kbps to 144 kbps (AW 96 MiniCell)  •  Provides 96 basic channel elements (AW 96 MiniCell) •  Multi-Carrier (hopping) Pilot Beacon capability (AW 10 Pilot Beacon) •  Easy repair and support  •  Provides an ‘All-IP’ solution •  Provides an effective solution for enterprise networks and hot spots. 4.2  IP- Base Station (BS) System Description The AW 96 IP-RAN (Internet Protocol Radio Access Network) is composed of two main modules:  The IP based BSC and the IP based BTS.  When an AirWalk IP-RAN is installed in an ‘ALL-IP’ network the integrated BTS is controlled by the integrated BSC, and the integrated BSC is controlled by a SS (Soft Switch). Legacy Switching Systems can also control the integrated BSC through standards based interfaces.  WirelessCore NetworkSS7 NetworkSGCore IP  NetworkHLRSMSCMSCIP-RAN(BSC+ BTS)IP-RANPDSNMGMGOAMSoftswitchSoftswitchBSCMacro NetworkMacro NetworkMicro NetworkMicro NetworkMulti- MediaInternetMulti- MediaInternetPSTNWirelessCore NetworkSS7 NetworkSGCore IP  NetworkHLRSMSCMSCIP-RAN(BSC+ BTS)IP-RANPDSNMGMGOAMSoftswitchSoftswitchBSCMacro NetworkMacro NetworkMicro NetworkMicro NetworkMulti- MediaInternetMulti-MediaInternetPSTNPSTN Figure 4-1 Network Diagram
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 15 of 56  6/14/2006 4.3 Hardware Configuration The IP-BS is a unique modular and stackable combination BSC and BTS platform that is differentiated from other systems.  Other systems have separate BTS and BSC platforms which adds to cost and complexity. The AirWalk RAN has a structure that combines and arranges the BSC interface with one the BTS in a single package. The main components are (depending on specific model): • AW-96 MiniCell o  CDPB (Common Digital Processing Board), consisting of:   CPIB (Channel Processor and IF Interface Board)   PCPM (Primary Call Processor Module)   GPSR (Global Positioning System Receiver)  o  XCVB (RF Transceiver Board) o  PSA (Power Supply Assembly)  o  RCPB (RF Power amplifer Board) 4 Watt CDMA Power Amplifier o  FEDB (Front End/Duplexer Board) Duplexer & Antenna Interface •  AW-10 Pilot Beacon o  CDPB (Common Digital Processing Board), consisting of:   CPIB (Channel Processor and IF Interface Board) PB Only   PCPM (Primary Call Processor Module)   GPSR (Global Positioning System Receiver)  o  XCVB-SP (RF Transceiver Board) Transmit Only configuration o  PSA (Power Supply Assembly)  o  RCPB (RF Power amplifier Board) 4 Watt CDMA Power Amplifier   4.3.1 Physical Description  •  AW 96 MiniCell / AW 10 Pilot Beacon o  Dimension: Max. 482mm(W) x 457mm(D) x 178mm(H) o  19” EIA Rack x 4 Rack Units o  Weight: 18 kg (3 Sector); 15 kg (Omni)   4.3.2 Typical Configurations  The following shows typical component configurations for common applications. Refer to the model charts for the contents of specific model numbers.  Omni medium power (4 Watt) MiniCell base station -  AW 96 MiniCell self contained unit  Omni Macrocell Pilot Beacon System (4w PPS) -  AW 10 Pilot Beacon self contained unit  Omni Multi-Carrier Macrocell Pilot Beacon System (4w PPS, 3 carrier hopping) -  AW 10 Pilot Beacon self contained unit with Multi-Carrier software option
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 16 of 56  6/14/2006  4.3.3 Installation Photographs  The following photographs show typical field installations for AW 96 MiniCell and AW 10 Pilot Beacon systems:      Figure 4-2 – Typical AW 96 MiniCell & AW 10 Pilot Beacon System            Figure 4-3 – Typical AW 96 MiniCell / AW 10 Pilot Beacon Rack Mounted
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 17 of 56  6/14/2006 4.4  Block Diagram – AW 96 MiniCell / AW 10 Pilot Beacon                 Figure 4-6 AW 96 / AW 10 Hardware Structure   AW 10 Pilot Beacon Notes: -  FEDB not provided on AW 10 models -  AW 10 XCVB may not be equipped with diversity receiver -  AW 10 CPIB may not be equipped with 3 CSM-5000 or receiver A/D & IF  Processor(MPC8250)CSM5KX3FPGA(ControlLogic)IF I/F - α(A/D & D/A)IF I/F - β(A/D & D/A)IF I/F - γ(A/D & D/A)GPSRXCVBUPCBDNCBDPLPSAProcessor(MPC8260)Memory BlockGateway I/FCPIBPCPMFrom/ToCA &WPMHPAU(4/8Watt)From/ToAntennaRCPBDuplexerFEDBToRCPBProcessor(MPC8250)CSM5KX3FPGA(ControlLogic)IF I/F - α(A/D & D/A)IF I/F - β(A/D & D/A)IF I/F - γ(A/D & D/A)GPSRXCVBUPCBDNCBDPLPSAProcessor(MPC8260)Memory BlockGateway I/FCPIBPCPMFrom/ToCA &WPMHPAU(4/8Watt)From/ToAntennaRCPBDuplexerFEDBToRCPB
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 18 of 56  6/14/2006 4.5  System Capacities and Specifications 4.5.1  AW 96 Technical Specification Item  Capacity and Specification   Remarks   Up-Link: 1850 ~ 1910 MHz Down-Link: 1930 ~ 1990 MHz  North American PCS Band Up-Link: 824 ~ 849 MHz Down-Link: 869 ~ 894 MHz  800 MHz Cellular Band Frequency Band   FA  1FA/Omni 3FA Hopping Pilot Beacon  Each AW 96 / AW 10 Unit Channel Elements / IP-BS  96CE  AW 96 MiniCell Handoff  Softer H/O, soft H/O. Hard H/O   Diversity Receiver  2 branch with imbalance alarm  AW 96 MiniCell GPS  External GPS Antenna  One per AW-96 / AW 10 Installation  Rack Mountable   4 Rack Units Cooling  Forced Air  Front To Rear Flow IP-Network Interface  10/100 Base-T Ethernet   Transmitter output power  4W Internal RU system  Includes duplexer (MiniCell) RF Interface  Antenna A (Tx/RxA) Antenna B (RxB)  CDMA 2000 1x Common Air Interface (CAI)  J-STD-008/IS-95-A/IS-95B /CDMA2000-1x   Channel bandwidth  1.25MHz   Receiving sensitivity  Less than 1% FER, when the power is under -119dBm  AW 96 MiniCell     Mechanical Specification RF Input and Output Connector  SMA Female (Input/Output)  From/To Antenna System AC Power Connector  IEC   Ethernet Signal Port Connectors  RJ-45  Dimensions ( W x H x D )  482mm(W) x 457mm(D) x 178mm(H)  4 Rack Units Weight  20 kg  AW 96 / AW 10 Table 4-1 – AW-96 MiniCell / AW 10 Pilot Beacon Specifications
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 19 of 56  6/14/2006 4.5.2  IP-BS Power Supply & Environment Technical Specification Input Power Supply Input Voltage:  AC 100Volts ~ 250Volts Input Frequency:  50Hz ~ 60Hz Dissipated Power AW-96 Main Unit:  350 Watt Max (Efficiency 75%)   Environment Specification Operating Temperature  0o ~ +50 o Storage Temperature  -30 o ~ +60 o Relative Humidity   5% ~ 95% - Non-condensing Noise  Less than 60dBA, distance 1.5m Airborne Particle  0 ~ 90 ㎍/㎥   Table 4-3 - Power Supply & Environment Specifications
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 20 of 56  6/14/2006 5  AW 96 MiniCell / AW 10 Pilot Beacon Components 5.1  AW-96 / AW 10 Main Unit     Figure 5-1 AW-96 Main Unit Photo (Front View)          Figure 5-2 AW-96 Main Unit Line Diagram (Front View) FEDB: AW 96 MiniCell Only CDPBXCVBRCPBFEDBPSU
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 21 of 56  6/14/2006  Figure 5-3 AW-96 Main Unit Photo (Back View)   Figure 5-4 AW-96 – Line Diagram (Back View)
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 22 of 56  6/14/2006 5.2 Component LED Configuration CDPB: LED status indicators are provided on the AW-96 CDPB module. LED functions are described in the following pictures and tables.  CPIB  GPSRPCPMSCPMCDPB PWR  FLT  BTSMMI  BSCMMI RESETCPIB PCPM SCPM Figure 5-9 CDPB Panel Diagram  Figure 5-10 - CDPB Panel Photo  Name  Color  On  Off  Note 1 CPIB Green Normal Abnormal CPIB power on/off indicator 2  GPSR  Green  Normal  Abnormal  GPSR power on/off indicator 3  PCPM  Green  Normal  Abnormal  PCPM power on/off indicator 4  SCPM  Green  Normal  Abnormal  SCPM power on/off indicator 5 CPIB Orange Abnormal Normal Check function of CPU in CPIB Board and ALARM 6  GPSR  Orange  Abnormal Normal  GPSR alarm on/off indicator 7 PCPM Orange Abnormal Normal  Check function of CPU in PCPM Board and ALARM 8 SCPM Orange Abnormal Normal  Check function of CPU in SCPM Board and ALARM Table 5-1 – CDPB Indicator Codes NOTE: AW-96 / AW 10 models are NOT normally equipped with an SCPM (Secondary Call Processor Module), therefore these indicators are not used in most system applications.  XCVB: The XCVB module is equipped with 2 indicators. LED functions are described in the following pictures and tables.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 23 of 56  6/14/2006  XCVBPWR FLT  Figure 5-11 - XCVB Panel Diagram  Figure 5-12 XCVB Panel Photo  Name  Color  On  Off  Note 1  PWR  Green  Normal  Abnormal  XCVB power on/off indicator 2  FLT  Orange  Abnormal  Normal  XCVB alarm on/off indicator Table 5-2 - XCVB Indicator Code Key RCPB: The RCPB module is equipped with 2 indicators. LED functions are described in the following pictures and tables.   Figure 5-13 - RCPB Panel Diagram  Figure 5-14 RCPB Panel Photo  Name  Color  On  Off  Note 1  PWR  Green  Normal  Abnormal  RCPB power on/off indicator 2  ACT/FLT  Green  Normal  (power off)  RCPB alarms are clear 2  ACT/FLT  Orange  Abnormal  (power off)  RCPB alarm/fault Table 5-3 - RCPB Indicator Code Key RCPBACT/FLTPWRRCPBACT/FLTPWR
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 24 of 56  6/14/2006 6  AW 96 / AW 10 Interface Cabling  6.1  RF Cabling – AW 96 MiniCell The AW 96 MiniCell Antenna ports are connected to the external diversity antenna systems as shown in Figure 6.1 (cables not included). External connectors are SMA type. In a non-diversity application, connect the antenna system to the main antenna port. Note the internal duplexer function provides a duplexed TX/Rx connection at the main antenna port (marked Txα on some enclosures).  Antenna systems must include suitable protection against lightning and other hazards in accordance with conventional cell site installation practices.           Figure 6-1 AW 96 MiniCell RF Cabling Diagram 6.2  RF Cabling – AW 10 Pilot Beacon The AW 10 Pilot Beacon Antenna port is connected to the external antenna system as shown in Figure 6.2 (cables not included). External connector is SMA type. The AW 10 Pilot Beacon is not equipped with any receivers, therefore there is no duplexer requirement for normal operation. Note the main antenna port may be marked Txα on some enclosures.  Antenna systems must include suitable protection against lightning and other hazards in accordance with conventional cell site installation practices.   GPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)GPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)To MainAntenna To DiversityAntenna
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 25 of 56  6/14/2006       Figure 6-2 AW 10 Pilot Beacon RF Cabling Diagram  6.3  Ethernet/Serial Cable Wiring (AW 96 / AW 10) Connect the external Ethernet connections (cable not supplied) from the local Ethernet switch or hub at the cell site to the BTS and BSC Ethernet ports on the AW-96 /AW 10 as shown in Figure 6.3. Use category 5 Ethernet cable (or better) for best performance.  6.4  Electric Power Cable Wiring (AW 96 / AW 10) Connect AW-96 /AW 10 to suitable AC power sources as shown in Figure 6-3. Use only the AC power cables provided with AW 96 / AW 10 unit to ensure continued safe operation.            Figure 6-3 AW 96 / AW 10 Power & Ethernet Cabling  GPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)GPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)To LocalEthernetSwitch/HubACPowerGPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)GPSANTRF RXA(a) RF TX (a)RF TX(b)RF RXB(r) RF RXA(r) RF TX (r)T_EVENT_10MHzRU IF BSC IFENV IF BTS IFRF RXB(a)RF RXB(b) RF RXA(b)To MainAntenna
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 26 of 56  6/14/2006 6.5  Photograph Of Typical Cable Wiring Figure 6-4 shows the actual cabling found in a typical system installation.       Figure 6-4 – AW 96 MiniCell Field Installation Photograph
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 27 of 56  6/14/2006 7  Frequency Setting Procedures 7.1 BSM Management The AW-96 series base stations are normally managed by the centrally located BSM (Base Station Manager) system which communicates with the AW-96 over an IP connection. The BSM will download system software and configuration information which includes the physical FA (Frequency Assignment) for each base station. The base station will tune to the correct frequency as defined by the BSM configuration files. Refer to the BSM operations manual for instructions on base station remote configuration. 7.2  Local FA Setting It may required to set the AW-96 series base station physical FA (frequency assignment) locally for specialized test purposes or when the BSM connection is unavailable (for example during early BTS installations). This can be done using the local MMI (Man Machine Interface) port and a local PC.  The configuration data downloaded from the BSM will override local settings when BSM connections are established. Refer to the MMI instruction manual for further information on other commands. 7.2.1 MMI Connection Connect the serial port of the PC to the “BTS MMI” port on the AW-96 front panel. Use the cable described in section 8.3.1 and the following port settings: 9600 baud 8 bit No Parity 1 stop bit No flow control
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 28 of 56  6/14/2006  7.2.2  FA Change Procedure The following menu driven commands will permit local change of the FA.  Step 1 At the prompt enter the following: > pn3383          // this will take you to the menu screen which looks something like this:  =================  PN 3383  ====================      1. Tx Test      2. Rx Test      3. ParameterSetup      4. Rf Gain Display      5. xcvbSetup      6. ampSetup      7. Normal Gain Display      8. MakeTestCall      9. callClear     10. Overhead Calibration Control     11. Test Phone Setup (619 2221001)     12. Handoff Test      0. Exit  --------------------------------------------------      Select Number ===> Step 2 Enter the following: Select number => 5    // it will take you to the below menu screen.          =================  Xcvb Setup  ====================      1. Change Ch      2. Tx On      3. Tx Off
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 29 of 56  6/14/2006      4. Rx_Main_AGC ON      5. Rx_Main_AGC OFF      6. Rx_Sub_AGC ON      7. Rx_Sub_AGC OFF      8. Set RxMain ATT      9. Set RxSub ATT     10. Set Tx Att     11. Xcvb Status     12. showXcvrAttGain      0. Exit  --------------------------------------------------      Select Input Number =====> Step 3  Enter the following: Select Input Number => 1  // choosing 1 will take you to the below menu.  ALPHA : xcvrChangeCh Num [001 ~ 1500] [1175] [/0:Exit]==> Step 4 From the above menu, type the new channel desired (CDMA channels from 1 to 1500) and 0 to exit.  Note that for 3 sector base stations Step 3 must be repeated for each sector (alpha, beta, and gamma). Note that only standard CDMA channel numbers within the designated band capability of the radio will be accepted by the base station.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 30 of 56  6/14/2006 8 Installation Procedures This Section gives definitions and instructions for installing the AW-Series IP-RAN and for connecting it to the wireless carriers infrastructure.  It contains detailed definitions needed for completing site Installation Checklist (Appendix B). 8.1 Installation Verification Before installing the equipment, it is necessary to verify the following: 8.1.1  Verify Customer Contact & Equipment location 8.1.1.1 Contact Customer1 1)  Verify contact name check Site Preparation Planning Checklist Appendix B. 2)  Verify contact phone number. 3)  Introduce yourself to the Customer contact. 4)  Introduce Installation team (if more than one person on team). 5)  Verify that all current customer contacts are listed. a)  Verify that contacts can solve problems within a timely manner for: i) Power Connection(s), ii) T1 Connection(s), iii) LAN Connection(s), iv)  If not, have main customer contact provide names and method of contacting. 6)  Determine when contacts are available for help (e.g.; Time of day, day of week.). 7)  Obtain any site access or security requirements (e.g.: ID Badges, Card-keys, Keys, Access codes) required to access installation site. 8)  Indicate all changes on checklist. 8.1.1.2  Locate AW-SERIES IP-RAN Equipment.2 1) Determine where AW-SERIES IP-RAN is stored.  2)  Check for any visible shipment damage.                                                        1 NOTE: Make sure all changes are sent to the Installation Coordinator Immediately. 2 NOTE: If any visible damage contact the Installation Coordinator immediately.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 31 of 56  6/14/2006 8.1.1.3  Locate and verify floor space. 1)  Determine where the AW-SERIES IP-RAN is to be installed (Refer to site diagram in Appendix B). 2)  Verify that there is enough space to safely install it (Refer to site diagram in Appendix B). 8.1.2  Uncrate and arrange for packing material disposal 1)  Carefully unpack the AW-SERIES IP-RAN and related components from packing material. 2)  Check for any shipment damage.3 3)  Be certain that all components match system order.4 4)  Make arrangements with customer contact on where, when, and how to dispose of all AW-SERIES IP-RAN packing material. 8.1.3  Verify location of all Facility distribution points  (main and intermediate) 8.1.3.1 Power Check. 8.1.3.1.1 Power Location 1)  Locate the customer provided power connection. a)  There should be a –48VDC connection for DC powered models (if required). b)  There should be a 120 or 240 VAC connection for AC powered models (if required). 8.1.3.1.2 Verify Connector. 1)  An 8 AWG three wire stranded cable to connect to a WECO DC terminal block connector is required for –48VDC (if required). 2)  A 6ft (1.84m) e conductor type SJT cables with standard grounded connector is required for 110VAC connection (if required).                                                       3 NOTE: Note any damage on shipping report, and Installation Checklist. Contact the Installation Coordinator immediately 4 NOTE: If components do not match the system order, contact the Coordinator immediately.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 32 of 56  6/14/2006 8.1.3.1.3 Voltage  1)  Using a power meter check for correct voltage. a)  –48VDC range is 40VDC to 57VDC (if required). b)  120 VAC range is 90 VAC to 132 VAC (if required). c)  240 VAC range is 180 VAC to 264 VAC (if required). 8.1.3.1.4 Amps 1)  Check cables to determine if they will handle required Amps. a)  –48VDC should be able to support 27.9 Amps. b)  120 VAC should support 15 Amps, 240 VAC should support 7.5 Amps 8.1.3.1.5  LAN Facilities check. 1)  Location – Locate the customer provided LAN connections. 2)  Verify IP Address (Site Prep Checklist Appendix B). 3)  Verify Connector is an RJ45 (if not contact customer). 4)  Connect Laptop and Ping IP Address. 5)  Prepare a site IP addressable device diagram showing the IP address for each device at the base station site. This diagram is essential for any needed troubleshooting activities. 6)  Post the diagram at the site and return a copy to the customer’s maintenance center and a copy to the AirWalk customer service center: AirWalk Customer Service Centre 1830 North Greenville Ave., Richardson, Texas   75081   8.2  AW-SERIES IP-RAN Install Procedures 8.2.1  Install AW-SERIES IP-RAN Cabinet Move AW-SERIES IP-RAN to location. Secure AW-SERIES IP-RAN in designated location  (Bolt down or Secure Wheels if provided). 8.2.2   Verify All Internal System Connections To verify all internal connections refer to the Section and Figures in the following Table for proper cable installation. This section not applicable to AW 96 MiniCell / AW 10 Pilot Beacon products
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 33 of 56  6/14/2006 Section  Description  Reference  3 6.1  RF Cable - AW-96 RU   N/A   6.3  Ethernet Cable – AW-96 to RU  N/A   Table 7-1 - Internal System Cable Reference 8.2.3  External System Connections5 To install new internal connections refer to the Section and Figures in the following Table for proper cable installation. Section  Description  Reference  3 6.1  External Diversity Antenna System   Figure 6-2   6.2  Electrical Power Cable  Figure 6-3 Use AC power cables supplied with AW-96.   6.3  External BSC & BTS Ethernet Cable   Figure 6-4   6.4  External GPS Antenna Cable   Figure 6-5    Table 7-2 - External System Cable Reference 8.2.4  Connect Power to Cabinet Connect -48VDC to DC distribution panel (if applicable). Connect 120VAC or 240VAC to Rack AC distribution panel (if applicable). 8.2.5 Connect Communications Facilities Connect LAN Facilities to BSC Connect LAN Facilities to BTS.                                                       5 WARNING: Make sure all system power supplies are turned off. All breakers/Fuses are pulled on all main and intermediate panels. Then proceed with the Installation.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 34 of 56  6/14/2006 8.2.6 Power-up procedure67 8.2.6.1  Power-up Main cabinet. Make sure all appropriate LED’s are illuminated. 8.2.6.2  Complete any Configuration options. a)  Configure the AW-SERIES IP-RAN. i)  Outgoing and incoming channels. 8.3 System Test This section contains the system tests that should be completed to determine if AW-SERIES IP-RAN is operational. 8.3.1  PC to AW 96 cable A special cable is required to run the required certification tests. Connect a PC with the subject cable to run tests  BTSP1CONNECTOR DB9594837261RJ1RJ-451234567891012345678910BTSP1CONNECTOR DB9594837261RJ1RJ-451234567891012345678910Pin Configuration    DB9 RJ-45(Computer) (BTS)     5    3     3    5     2    7 Figure 7-1 - PC to AW 96 Cable Specifiaction                                                       6 Note: Once all connections are made, make sure to: Reset/install all breakers/fuses for all main and intermediate breaker/fuse box(s). Then proceed with the Installation. 7 Make sure all added cabling is tie-wrapped correctly
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 35 of 56  6/14/2006   Figure 7-2 - PC to AW 96 / AW 10 Cable Connection Diagram 8.3.2 System Certification Tests Start The AW-SERIES IP-RAN tests. This sequence of test cases is designed to certify the AW 96 IP-RAN installation. It is assumed the person running this checklist is familiar with the basics of configuring, running, stopping, and starting the AW 96 IP-RAN. 8.3.2.1  Test Case #1 - Image/PLD loading 8.3.2.1.1  Test Procedure #1 •  Command:   user: ipbs001 FTP password: ipbs001 • Command:    Edit: - P: display - C: edit 8.3.2.1.2  Expected Result of Case #1 Screen from PC using ftp Server is shown in Figure 7-3.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 36 of 56  6/14/2006  Figure 7-3 - Screen from PC Screen from WPM  Figure 7-4 - Screen from PC 8.3.2.2  Test Case #2 – System Check 8.3.2.2.1  Test Procedure #2 • Command: Version 8.3.2.2.2  Expected Result of Case #2
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 37 of 56  6/14/2006  Figure 7-5 - Version Command Screen 8.3.2.3  Test Case #3 – Tx check 8.3.2.3.1  Test Procedure #3 •  Command: txReason  •  Expected Result of Case #3  Figure 7-6 - Tx Check Screen 8.3.2.4  Test Case #4 – Output power 8.3.2.4.1  Test Procedure #4 – RF Check • Command: showRfGain 8.3.2.4.2  Expected Result of Case #4
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 38 of 56  6/14/2006  Figure 7-7 - RF Check Screen 8.3.2.5  Test Case #5 – GPS Check 8.3.2.5.1  Test Procedure #5 • Command: gpsStatus 8.3.2.5.2  Expected Result of Case #5  Figure 8-8 – GPS Status Check Screen  Figure 8-9 - GPS Alarm Check Screen
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 39 of 56  6/14/2006 8.3.2.6  Test Case #6 – BTS Alarm Check 8.3.2.6.1  Test Procedure #6 • Command: showAlarm 8.3.2.6.2  Expected Result of Case #6  Figure 8-10 - BTS Alarm Check Screen 8.3.2.7  Test Case #7 – System Reset 8.3.2.7.1  Test Procedure #7 • Command: btsReset/bscReset/allReset 8.3.2.7.2  Expected Result of Case #7 The system is RESET  8.3.2.8  Test Case #8 – PN Check 8.3.2.8.1  Test Procedure #8 •  Command: RcmCmd 1,1  8.3.2.8.2  Expected Result of Case #8
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 40 of 56  6/14/2006  Figure 8-11 - PN Check Screen 8.3.2.9  Test Case #9 – System Interface Check 8.3.2.9.1 Test Procedure • Command: Ping Send Ping Command to the Following system IP Addresses 1.  WPM (Wireless PBX Manager)  2.  PDSN (Packet Data Serving Node) 3.  CA (Call Agent) 4.  MG (Media Gateway) 5.  SG (Signal Gateway) 8.3.2.9.2  Expected Result of Case #X A successful PING command response from each system. 8.3.3 Operation Tests These test cases are designed to determine if AW 96 is ready for production testing. 8.3.3.1  Test Case #1 – Voice Calls 8.3.3.1.1 Test Procedure Test Call From MS #1 to MS #2. Test Call From MS #1 to Landline Phone #1. 8.3.3.1.2  Excepted Result of Case #1 1. 2nd MS Rings and call is answered
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 41 of 56  6/14/2006 2.  Landline phone Rings and call is answered.  8.3.3.2  Test Case #2 – Data Calls 8.3.3.2.1 Test Procedure 1.  A Test Data Call From MS #1 to MS #2. 2.  A Test Data Call From MS #2 to MS #1. 8.3.3.2.2  Excepted Result of Case #2 1.  A Data Session is established between MS #1 and MS #2. 2.  A Data Session is established between MS #2 and MS #1. 8.3.4 Operator Specific Tests These test cases are covered in a separate test plan document and are agreed to by the operator and AirWalk Communications, Inc. 8.4  Site Clean up and Customer Signoff 8.4.1  Dispose of all packing material. Make sure to dispose of all AW-SERIES IP-RAN packing material. 8.4.2 Clean-up site. Make sure not to leave anything but the installed AW-SERIES IP-RAN. (e.g., excess tie-wraps, bolts, etc). 8.4.3  Update Installation Checklist. Make sure all changes are notes on Installation Checklist. 8.4.4 Customer Signoff. Get Customer Signature on Certification Document Appendix D. 8.5  Required Tools and Supplies 1) Hand Tools a) Screwdriver set, b) Pliers set, c)  Nut Driver set, d) Cutter set, e) Punch Down Tool, f) Wire-wrap (Optional), g) RJ-45 Crimper.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 42 of 56  6/14/2006 2) Test Equipment. a)  Multi-Meter & Adapter kit, b) Cable Tester, c)  Protocol Analyzer & Adapter kit, d)  Telephone Test Set (Butt-set), e)  Set of Banjo adapters f)  Tone Generator & Inductive pick-up. 3) Supplies. a) RJ-45, b)  Cat 5 Cable, c) Tie-wraps. 8.6 Troubleshooting Procedures The AW-SERIES IP-RAN is designed to provide reliability and consistently high performance in all network environments. The installation procedure for the AW-SERIES IP-RAN is a straightforward and is discussed in these sections. Should problems develop during installation, this section is intended to help locate, identify and correct these types of problems. Please follow the suggestions listed below prior to contacting AirWalk Communications, Inc. or Carrier contacts. If you are unsure of the procedures described in this section, contact the Installation coordinator immediately. 8.6.1  Before Calling for Assistance 1)  If difficulty is encountered with a specific component of the AW-SERIES IP-RAN, refer back to the Installation Section for that component. 2)  Check the cables and connectors to ensure that they have been properly connected and the cables/wires have not been crimped or impaired in some way during installation. (About 90% of component problems can be attributed to wiring and connector problems). a) Check Cable, b) Check connector, c)  Check for solid connection, d)  Check with Carrier contact. 3)  Make sure that all power cord is properly attached to each AW-SERIES IP-RAN component. Be certain that all power cords are plugged into a functioning electrical outlet. Use the PWR LED’s to verify each unit is receiving power. a)  Check intermediate breakers or fuses. 4)  If the problem is isolated to something other than the AW-SERIES IP-RAN contact the appropriate Carrier contact.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 43 of 56  6/14/2006 5)  Verify whether or not the problem is corrected. If not, go to Step 6 below. If the problem is corrected, continue with installation. 6)  If the problem continues after completing Step 4 above, contact the AirWalk Communications, Inc. Installation Project manager, to determine the next course of action. 8.6.2  When Calling for Assistance Please be prepared to provide the following information. 1)  A complete description of the problem, including the following points: a)  The nature and duration of the problem;  b)  Situations when the problem occurs;  c)  The components involved in the problem;  d)  Any particular application that, when used, appears to create the problem; 2)  A record of changes that have been made to the AW-SERIES IP-RAN configuration prior to the occurrence of the problem. 3)  Any changes to system should all be noted.
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 44 of 56  6/14/2006 9  Appendix A - Acronyms Acronym  Description 2G  Second Generation in CDMA wireless network 3G  Third Generation in CDMA wireless network AC Alternating Current Access Channel A Reverse CDMA Channel used by mobile stations for communicating to the base station. The Access Channel is used for short signaling message exchanges, such as call originations, responses to pages and registrations. The Access Channel is a slotted random access channel. ACH Access Channel AD  Analog to Digital AFEU  Antenna Front End Unit AGC  Automatic Gain Control ANT Antenna AWGN  Additive White Gaussian Noise Base Station (BS) A fixed station used for communicating with mobile stations. Depending upon the context, the term base station may refer to a cell, a sector within a cell, an MSC, or other part of the wireless system. BCCM  BTS Call Control Module BHCA  Busy Hour Call Attempts BLK Blank BS Base Station BSAP  Base Station Application Part BSC Base Station Controller BSMAP  Base Station Management Application Part BTS  Base station Transceiver Subsystem CA Call Agent CAI  Common Air Interface CC Connection Confirm CCM  Channel Control Module in BTS CDMA  Code Division Multiple Access CEC  Channel Elements Control Block CED  Channel Elements Diagnostic Block CLAP  Composite Link Analysis Platform CPIB  BTS Channel and Call Processing Interface Board CPU  Central Processing Unit CR Connection Request CREF Connection Refused CSM5000  Cell Site Modulator 5000 (CDMA ASIC chip released by Qualcomm for cdma2000) DA  Digital to Analog DC Direct Current DCCH  Dedicated Control Channel DCLI  Data Link Connection Identifier DRS  Data Ready to Send DT Data Form
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 45 of 56  6/14/2006 Acronym  Description DTAP  Direct Transfer Application Part EMI Electro-Magnetic Interference ESN  Electronic Serial Number EVDO  Evolution Data Only EVDV  Evolution Data and Voice EVRC  Enhanced Variable Rate CODEC FA Frequency Assignment FCC Federal Communications Commission F-CCH  Forward Common Control Channel FCH Fundamental Channel F-DCCH  Forward Dedicated Control Channel FDCH  Forward Dedicated Signaling Logical Channel FER Frame Error Rate FM Fault Management FO Frame Offset Forward Traffic Channel One or more code channels used to transport user and signaling traffic from the base station to the mobile station.  FSCH  Forward Common Signaling Logical Channel GND Ground GPS  Global Positioning System GRE  Generic Routing Encapsulation HLR  Home Location Register HO Handoff HPAU  High Power Amplifier Unit IF Intermediate Frequency IMSI  International Mobile Subscriber Identity ING  Inter Network Gateway IOS Interoperability System IP Internet Protocol IPC  Inter Processor Communication LAC Link Access Control. Entity that provides assured mode or unassured mode delivery of information across the air interface between the mobile station and the base station. LPA  Linear Power Amplifier LTU Logical Transmission Unit One or more Type 3 or Type 5 MuxPDUs with a 16bit CRC. MAC Medium Access Control Entity that controls the access to and from Upper Layer Signaling, Data Services and Voice Services to Physical Layer resources. MAHHO  Mobile Assisted Hard Hand Off MCC  Main Call Control module in IP-BSC MG Media Gateway MIMO  Multi Input Multi Output MIN Mobile Identification Number MMC Man-Machine Command MMS  Multimedia Messaging Service MN Mobile Node
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 46 of 56  6/14/2006 Acronym  Description MS Mobile Station MSC  Mobile Switching Center MTBF  Mean Time between Failure MTTR  Mean Time to Repair NDSS  Network Directed System Selection NGN  Next Generation Networks NMS  Network Management System OAM  Operation, Administration, and Maintenance OCNS  Orthogonal channel Noise Simulator OS Operating System OTD  Orthogonal Transmit Diversity OUNS  Other User Noise Source PACA  Priority Access Channel Assignment Paging Channel A code channel in a Forward CDMA Channel used for transmission of control information and pages from a base station to a mobile station PBA  Printed Board Assembly PBX  Private Branch Exchange PCB  Printed Circuit Board PCF  Packet Control Function in IP-BSC PCH Paging Channel PCM Pulse Code Modulation PCPM  Primary BSC Call Processing Board PDSN  Packet Data Serving Node PDU  Protocol Data Unit. An atomic set of data, header information, and control information that are provided by a service user to a service provider. PER Packet Error Rate Physical Channel Radio transmission link Pilot Channel An un-modulated, direct-sequence spread spectrum signal transmitted by a CDMA base station or mobile station. A pilot channel provides a phase reference for coherent demodulation and may provide a means for signal strength comparisons between base stations for determining when to handoff. PLD  Program Loaded Data PN Pseudo Noise PSA  Power Supply Assembly PSTN  Public Switched Telephone Network QCELP  Qualcomm Code Excited Linear Prediction QOF Quasi-Orthogonal Function QOF  Quasi Orthogonal Function QoS  Quality of Service RAN  Radio Access network RC Radio Configuration RCC  Radio interface Call Control RDCH  Reverse Dedicated Signaling Logical Channel Reverse Traffic Channel A traffic channel on which data and signaling are transmitted from a mobile station to a base station. The Reverse Traffic Channel is composed of up to one Reverse Dedicated Control Channel, up to one Reverse Fundamental Channel, zero to two Reverse Supplemental Channels, and zero to seven Reverse
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 47 of 56  6/14/2006 Acronym  Description Supplemental Code Channels. RF Radio Frequency RLC Release Complete RLP  Radio Link Protocol. Connection-oriented, negative-acknowledgement-based data delivery protocol. RLSD Released RP  Radio Network – PDSN RPSU  Remote RF Power Supply Unit RRCU  Remote RF Control Unit RRM  Radio Resource Management Block RRP Registration Reply Message RRQ Registration Request Message RSCH  Reverse Common Signaling Logical Channel RSSI  Received Signal Strength Indication RTP  Real-Time Transport Protocol RU  Remote RF Unit RUpd Registration Update Message SAP  Service Access Point Conceptual point at the interface between two adjacent layers where services are provided to the upper layer and data and protocol information is exchanged between layers. SAR  Segmentation and Reassembly SCCH Supplemental Code Channel SCCP  Signaling Connection Control Protocol SCH Supplemental Channel SDU  Selection and Distribution Unit SEU Sector Expansion Unit SIGTRAN  Signaling Transport processing module in IP-BSC Slotted Mode  An operation mode of the mobile station in which the mobile station monitors only selected slots on the Paging Channel SMS  Short Message Service SMV  Selectable Mode VOCODER SRBP  Signaling Radio Burst Protocol. An entity that provides connectionless protocol for Signaling messages. SRU Sector Reduction Unit SS Soft Switch STS Space Time Spreading Sync Channel A code channel in the Forward CDMA Channel which transports the synchronization message to the mobile station TCC  Traffic Channel Control Block TCE  Traffic Channel Element TCM  Traffic Control Module in BTS TCP  Transmission Control Protocol TOD  Time of Day TP  Traffic processing and Path Control module in IP-BSC TPTL  Transmit Power Tracking Loop UART  Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol
AW 96 Series System Installation Manual          ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 48 of 56  6/14/2006 Acronym  Description VSWR  Voltage Standing Wave Ratio XCV  Base Station Transceiver Control Block XCVR Transceiver Board
AW2100U System Installation Manual             __________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 49 of 56  6/14/2006 10 Appendix B - Site preparation checklist AW-Series IP-RAN Site Preparation Check List for:   {Customer Name}  ITEM #  Description Site Prep Guide Section # Date Complete Complete Information 1  Customer Contact & Equipment location  1   a. Main Contact Customer  1.1.1   b. Other Customer Contacts  1.1.2     1. Power contact  1.1.2     2. Communications Facilities Contact  1.1.2     3. LAN Facilities Contact  1.1.2     4. MSC Security Contact  1.1.2   c. Complete Customer Questions Appendix C  App. C  2  AirWalk Series IP-RAN Site Requirements  2.1   a. Space requirements  2.1.1   b. AirWalk Series IP-RAN placement Diagram  2.1.2   c. Installation Location for AirWalk Series IP-RAN Equipment  2.1.2.1  3  Complete Site Drawings Appendix B  App. B
AW2100U System Installation Manual             __________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 50 of 56  6/14/2006 ITEM #  Description Site Prep Guide Section # Date Complete Complete Information  Power requirements  2.1.3   a. Location     b. Voltage     c. Amps     d. Connector      Security  2.1.3   a. MSC Equipment Room security     b. MSC Equipment room access      Communications Facilities  2.1.3   a. Number of T1 circuits      Connector      Location      LAN Facilities  2.1.3   a. Location     b. Connector     c. Carrier Network IP Address     d. AirWalk Series IP-RAN Component IP Addresses      Other Information
AW2100U System Installation Manual             __________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 51 of 56  6/14/2006 ITEM #  Description Site Prep Guide Section # Date Complete Complete Information a. Heat dissipation     b. Environmental specifications  2.1.4   c. Ambient temperature and humidity  2.1.4.2  d. Dust density  2.1.4.4  e. Altitude  2.1.4.5  f. Air conditioning  2.1.4.6  g. Fire protection
AW2100U System Installation Manual             ____________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 52 of 56  6/14/2006 11  Appendix C - Installation Checklist AW-Series IP-RAN Site Installation Check List for:   {Customer Name} Address  Installer Name (s)  Customer Contact (s) {AW-SERIES IP-RAN Installation Address}     ITEM #  Description  Install Manual Section Date Complete Time  Customer Contact Initials Installer Initials 1  Verify Customer Contact & Equipment location  9.1.1         2 Contact Customer  9.1.1.1        3  Locate AW-SERIES IP-RAN Equipment 9.1.1.2     4  Locate and verify Floor Space  9.1.1.3         5  Uncrate and arrange for packing material disposal  9.1.2         6  Verify location of all distribution points (main and intermediate)  9.1.3         7 Power Check  9.1.3.1        8 Power Location  9.1.3.1.1        9 Verify Connector  9.1.3.1.2        10 Voltage  9.1.3.1.3        11 Amps  9.1.3.1.4        12  LAN Facilities check 9.1.3.1.5     13 Location  9.1.5.1.5        14  Verify IP Address  9.1.3.1.5         15 Verify Connector  9.1.3.1.5        16  Ping IP Address  9.1.3.1.5
AW2100U System Installation Manual             ____________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 53 of 56  6/14/2006 ITEM #  Description  Install Manual Section Date Complete Time  Customer Contact Initials Installer Initials 17  Prepare IP addressable device diagram  9.1.3.1.5         18  Post IP diagram at: i) site; ii) customer; iii) Airwalk Customer Service 9.1.3.1.5        19  Install AW-SERIES IP-RAN Cabinet  9.2.1         20  Move AW-SERIES IP-RAN to location  9.2.1         21  Secure AW-SERIES IP-RAN in designated location  9.2.1         22  Verify all internal System connections  9.2.2         23  External System Connections  9.2.3         MAKE SURE ALL SYSTEM POWER SUPPLIES ARE TURNED OFF BEFORE PROCEEDING! ! ! 24  Connect Power to Cabinet  9.2.4         25  Connect -48VDC to DC distribution panel (If applicable)  9.2.4         26  Connect 120-240 VAC to AC distribution panel (If applicable)  9.2.4         27 Connect Communications Facilities  9.2.5         28  Connect LAN Facilities to BSC  9.2.5         29  Connect LAN Facilities to BTS  9.2.5         30 Power-up procedure  9.2.6         31  Power-up Main cabinet/rack power, check LEDs  9.2.6.1         32  Complete any configuration options  9.2.6.2          System Certification Tests  9.3.2         33  Test Case #1 - Image/PLD loading  9.3.2.1         34  Test Case #2 – System Check  9.3.2.2         35  Test Case #3 – Tx check  9.3.2.3         36  Test Case #4 – Output power  9.3.2.4         37  Test Case #5 – GPS Check  9.3.2.5         38  Test Case #6 – BTS Alarm Check  9.3.2.6         39  Test Case #7 – System Reset  9.3.2.7         40  Test Case #8 – PN Check  9.3.2.8
AW2100U System Installation Manual             ____________________________________________________________________________________________________________________ AirWalk Proprietary and Confidential  Page 54 of 56  6/14/2006 ITEM #  Description  Install Manual Section Date Complete Time  Customer Contact Initials Installer Initials 41  Test Case #9 – System Interface Check  9.3.2.9          Operation Tests  9.3.3         42  Test Case #1 – Voice Calls  9.3.3.1         43  Test Case #2 – Data Calls  9.3.3.2         44  Operator Specific Tests (If Required)  8.3.4          Site Clean Up & Documentation           45  Dispose of all packing material  8.4.1         46 Clean-up site  8.4.2         47  Update Installation Checklist  8.4.3         48  Get Customer Signature on Certification Document  8.4.4
AW2100U System Installation Manual         ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 55 of 56  6/14/2006 12 Appendix D - Customer Certification Document    Date   Subject:   The subject AW-SERIES IP-RAN has been certified to be up and running today.   _______________________________________ __________________ AirWalk Communications, Inc. (Installation Team)    Date   _______________________________________ __________________ Authorized Carrier Representative        Date
AW2100U System Installation Manual         ___________________________________________________________________________ AirWalk Proprietary and Confidential  Page 56 of 56  6/14/2006       This Page Marks End Of Document

Navigation menu