AirWalk Communications AW96R19AF7 AW96R19AF7 MiniCell User Manual System Installation Manual

AirWalk Communications, Inc. AW96R19AF7 MiniCell System Installation Manual

System Installation Manual

Download: AirWalk Communications AW96R19AF7 AW96R19AF7  MiniCell User Manual System Installation Manual
Mirror Download [FCC.gov]AirWalk Communications AW96R19AF7 AW96R19AF7  MiniCell User Manual System Installation Manual
Document ID675000
Application IDMoOtCCC4WNs/LVxTnFn3HA==
Document DescriptionSystem Installation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize85.36kB (1067047 bits)
Date Submitted2006-06-29 00:00:00
Date Available2006-06-29 00:00:00
Creation Date2006-06-14 12:03:18
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2006-06-14 12:03:18
Document TitleMicrosoft Word - System Installation Manual-AW-10 PB-Mini_v1.1.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: cosborn

Installation & Maintenance Manual
AW-96 Mini-Cell
AW 10 Pilot Beacon
Version # 1.2
June 2006
Prepared By
AirWalk Communications, Inc.
1830 North Greenville Ave
Richardson, TX, 75081
Phone: (972) 638-9400
Fax: (972) 638-9401
www.airwalkcom.com
FOR USE BY TRAINED TECHNICIANS ONLY
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 1 of 56
6/14/2006
AW 96 Series System Installation Manual
Revision History
Version
0.1
1.0
1.1
1.2
Date
10/15/2005
11/23/2005
4/30/2006
6/14/2006
Person
CMO
CMO
CMO
CMO
Description
Draft Document
Released
Pictures corrected
Added regulatory compliance information
Revision Numbering Key
0.x
Work in Progress
1.0
Initial Document Approval
1.x
Revisions Following Initial Document Approval
2.0
Revisions Approval
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 2 of 56
6/14/2006
AW 96 Series System Installation Manual
Table of Contents
TABLE OF CONTENTS..................................................................................................................................3
INTRODUCTION.....................................................................................................................................5
1.1
PROPRIETARY INFORMATION NOTICE ..................................................................................................5
1.2
PURPOSE OF DOCUMENT ......................................................................................................................5
1.3
SCOPE ..................................................................................................................................................5
1.4
ORDER OF PRECEDENCE .......................................................................................................................5
1.5
TERMINOLOGY .....................................................................................................................................5
1.6
APPLICABLE DOCUMENTS ...........................................................................................................5
1.6.1
AirWalk Documents.....................................................................................................................5
1.6.2
Telecom Standards ......................................................................................................................6
1.6.3
Other Documents.........................................................................................................................6
AW-96 MINICELL / AW-10 PILOT BEACON MODEL STRUCTURE ...........................................7
2.1
2.2
2.3
1900 MHZ CONFIGURATIONS (PCS BAND)..........................................................................................7
800 MHZ CONFIGURATIONS ................................................................................................................8
450 MHZ (NMT BAND) CONFIGURATIONS ..........................................................................................9
AW 96 & AW 10 SAFETY AND COMPLIANCE INFORMATION ................................................10
3.1
STATEMENT OF INTENT .....................................................................................................................10
3.2
SAFETY PRECAUTIONS .......................................................................................................................10
3.3
MAINTENANCE INFORMATION ...........................................................................................................11
3.3.1
Cleaning ....................................................................................................................................11
3.3.2
Filter Maintenance ....................................................................................................................11
3.3.3
Fuse Replacement .....................................................................................................................11
3.3.4
Other Maintenance....................................................................................................................11
3.4
LABELING ..........................................................................................................................................12
3.4.1
Grounding .................................................................................................................................12
3.4.2
Label: Model Identification, FCC Identification, Power ..........................................................12
3.5
REGULATORY COMPLIANCE INFORMATION .......................................................................................13
3.5.1
Radio Interference (FCC 15.19 Statement)...............................................................................13
3.5.2
Unauthorized Modifications (FCC 15.21 Statement) ................................................................13
3.5.3
Digital Device Interference (FCC 15.105 Statement) ...............................................................13
3.5.4
RF Exposure (FCC MPC Compliance) .....................................................................................13
AW 96 / AW 10 SYSTEM INTRODUCTION......................................................................................14
4.1
OVERVIEW .........................................................................................................................................14
4.2
IP- BASE STATION (BS) SYSTEM DESCRIPTION .................................................................................14
4.3
HARDWARE CONFIGURATION ............................................................................................................15
4.3.1
Physical Description .................................................................................................................15
4.3.2
Typical Configurations..............................................................................................................15
4.3.3
Installation Photographs...........................................................................................................16
4.4
BLOCK DIAGRAM – AW 96 MINICELL / AW 10 PILOT BEACON ........................................................17
4.5
SYSTEM CAPACITIES AND SPECIFICATIONS ........................................................................................18
4.5.1
AW 96 Technical Specification..................................................................................................18
4.5.2
IP-BS Power Supply & Environment Technical Specification ..................................................19
AW 96 MINICELL / AW 10 PILOT BEACON COMPONENTS......................................................20
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 3 of 56
6/14/2006
AW 96 Series System Installation Manual
5.1
5.2
AW-96 / AW 10 MAIN UNIT ..............................................................................................................20
COMPONENT LED CONFIGURATION ..................................................................................................22
AW 96 / AW 10 INTERFACE CABLING ............................................................................................24
6.1
6.2
6.3
6.4
6.5
RF CABLING – AW 96 MINICELL ......................................................................................................24
RF CABLING – AW 10 PILOT BEACON ...............................................................................................24
ETHERNET/SERIAL CABLE WIRING (AW 96 / AW 10) .......................................................................25
ELECTRIC POWER CABLE WIRING (AW 96 / AW 10).........................................................................25
PHOTOGRAPH OF TYPICAL CABLE WIRING ........................................................................................26
FREQUENCY SETTING PROCEDURES ..........................................................................................27
7.1
BSM MANAGEMENT ..........................................................................................................................27
7.2
LOCAL FA SETTING ...........................................................................................................................27
7.2.1
MMI Connection .......................................................................................................................27
7.2.2
FA Change Procedure...............................................................................................................28
INSTALLATION PROCEDURES........................................................................................................30
8.1
INSTALLATION VERIFICATION ............................................................................................................30
8.1.1
Verify Customer Contact & Equipment location.......................................................................30
8.1.2
Uncrate and arrange for packing material disposal .................................................................31
8.1.3
Verify location of all Facility distribution points (main and intermediate)..............................31
8.2
AW-SERIES IP-RAN INSTALL PROCEDURES ...................................................................................32
8.2.1
Install AW-SERIES IP-RAN Cabinet.........................................................................................32
8.2.2
Verify All Internal System Connections.....................................................................................32
8.2.3
External System Connections ....................................................................................................33
8.2.4
Connect Power to Cabinet ........................................................................................................33
8.2.5
Connect Communications Facilities..........................................................................................33
8.2.6
Power-up procedure..................................................................................................................34
8.3
SYSTEM TEST .....................................................................................................................................34
8.3.1
PC to AW 96 cable ....................................................................................................................34
8.3.2
System Certification Tests .........................................................................................................35
8.3.3
Operation Tests .........................................................................................................................40
8.3.4
Operator Specific Tests .............................................................................................................41
8.4
SITE CLEAN UP AND CUSTOMER SIGNOFF ..........................................................................................41
8.4.1
Dispose of all packing material.................................................................................................41
8.4.2
Clean-up site. ............................................................................................................................41
8.4.3
Update Installation Checklist. ...................................................................................................41
8.4.4
Customer Signoff. ......................................................................................................................41
8.5
REQUIRED TOOLS AND SUPPLIES .......................................................................................................41
8.6
TROUBLESHOOTING PROCEDURES .....................................................................................................42
8.6.1
Before Calling for Assistance....................................................................................................42
8.6.2
When Calling for Assistance .....................................................................................................43
APPENDIX A - ACRONYMS................................................................................................................44
10
APPENDIX B - SITE PREPARATION CHECKLIST ...................................................................49
11
APPENDIX C - INSTALLATION CHECKLIST............................................................................52
12
APPENDIX D - CUSTOMER CERTIFICATION DOCUMENT ..................................................55
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 4 of 56
6/14/2006
AW 96 Series System Installation Manual
1 INTRODUCTION
1.1 Proprietary Information Notice
THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE
RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS
TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER
NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT
THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC.
1.2 Purpose of Document
The purpose of this document is to define the Installation, Maintenance and Safety
Compliance of AirWalk Communication’s, Inc. unique CDMA Radio Access Network
(RAN) system. The AirWalk RAN is a market ready, standards compliant, high channel
capacity, cost effective, modular and expandable wireless radio access network system.
Designed specifically for CDMA2000 networks, the Base Station Transceiver (BTS) and
Base Station Controller (BSC) are integrated into a single compact platform.
The target market and applications are in-building areas, corporations, corporate
campuses, enterprises, university campuses, large industrial plants, stadiums, airports,
shopping malls, blind spots, hot spots, rural areas, neighborhoods, and highways.
1.3 Scope
The scope of this document covers the description, environmental specifications,
equipment location, cabling, system installation and maintenance of the AirWalk RAN.
Specific models covered are identified in the section entitled “Model Information”.
1.4 Order of Precedence
This System Installation Manual will take precedence over any previous AirWalk System
Installation Manual or Document.
1.5 Terminology
See the section entitled: Appendix A - Acronyms
1.6 APPLICABLE DOCUMENTS
The following documents are applicable to the extent specified in this System Installation
Manual.
1.6.1 AirWalk Documents
•
IP- Base Station (BS) System Description.
•
IP- Base Station (BS) CPIB Block Diagram.
•
IP- Base Station (BS) GPSR Block Diagram.
•
IP- Base Station (BS) PCPM Block Diagram.
•
IP- Base Station (BS) XCVB Block Diagram.
•
AirWalk System Specification-11-13-2003-v1.0.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 5 of 56
6/14/2006
AW 96 Series System Installation Manual
•
System User Manual_022404.
•
System Installation Manual_030104.
1.6.2 Telecom Standards
•
TIA/EIA/IS-2000 Series Revision: C - Introduction to CDMA2000 Spread Spectrum
Systems, 05/00/02
•
Personal Station – Base Station Compatibility Requirements for1.8 to 2.0 GHz CDMA
PCS.
•
TIA/EIA-664 - Wireless Features Description, 12/00/00
•
TIA/EIA Interim Standard 95 Revision A - Mobile Station –Base Station Compatibility
Standard for Dual-Mode Wideband Spread Spectrum Cellular Systems, May 1995
•
TIA/EIA-95-B - Mobile Station-Base Station Compatibility Standard for Dual-Mode
Spread Spectrum Systems, October 31, 1998
•
MSC to BS Interface Inter-Operability Specification (IOS) IOS-4.2
•
IMT-2000 Specification, (indoor wireless propagation)
1.6.3 Other Documents
None Identified
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 6 of 56
6/14/2006
AW 96 Series System Installation Manual
2 AW-96 MiniCell / AW-10 Pilot Beacon Model Structure
2.1 1900 MHz Configurations (PCS Band)
AW96R19AJ7A01
AW96R1DAJ7A01
AW96R19AB3A01
AW96R19AJ3A01
AW96C19AJ3A01
AW96R1DAJ3A01
AW96C1DAJ3A01
AW10R19AF1A01
Assembly Part
Number
AW96R19AF7A01
Group
AW96R19AB7A01
High Level Model Structure Chart
(AW-96 Series 1900 MHz Band Configurations)
AW96R19AA1A01
This model chart covers all 1900 MHz (PCS band) configuration models. Not all models
are available in all markets. Clarify any model structure questions with Technical Support
Services or your Sales representative.
(Alt)
Name
Descripion
SUB0031
CDPB SUB00xx
Assy SUB00xx
CDPB
CDPB
CDPB
CPIB & PCPM 96 CE
CPIB & PCPM 32 CE (obsolete)
CPIB & PCPM PB Only
PBA0004
PBA0003
PBA0006
XCVB
XCVB
XCVB
1.9 GHz Dual Mode 1/50mW PCS
800 Dual Mode 1/50mW Cell Band
450 Dual Mode 1/50mW NMT (A/H)
XCVB
SUB0004
Assy
SUB00xx
SUB00xx
SUB00xx
XCVB
XCVB
XCVB
XCVB
2100 MHz 1mW (Japan Band)
1800 MHz 1mW (Korea Band)
1.9 GHz xmit ONLY (PB)
800 MHz Xmit ONLY (PB)
SUB00xx
RCPB
SUB00xx
Assy
RCPB
RCPB
5.0 Watt Internal PA Module 1.9 MHz
5.0 Watt Internal PA Module 800 MHz
SUB00xx
FEDB SUB00xx
FEDB
FEDB
MiniCell Internal Duplexer 1.9 GHz
MiniCell Internal Duplexer 800 MHz
SUB00xx
SUB00xx
Chassis SUB00xx
Assy SUB00xx
SUB00xx
Chassis
Chassis
Chassis
Chassis
Chassis
AW-96 Chassis - Onmi Internal PA
AW-96 Chassis - Onmi/1S
AW-96 Chassis - 2 Sector
AW-96 Chassis - 3 sector
AW-10 Chassis - Pilot Beacon
External Cable Kit - Omni RU
External Cable Kit - Sector RU - S1
External Cable Kit - Sector RU - S2
External Cable Kit - Sector RU - S3
Ext
Cable
Kits
CBK0005
CBK0006
CBK0007
CBK0008
Ext Cable
Ext Cable
Ext Cable
Ext Cable
Cord
SUB00xx
Pwr Cord Power Cord UL 16 Guage
(Alt)
RU
RU
RU
RU
Omni System - 1900 Band C/F
Omni System - 1900 Band A/B/D/E
Omni System - 800
Omni System - 450 NMT A Sub Band
RU Assy SUB00xx
SUB00xx
SUB0029
SUB00xx
SUB00xx
RU
RU
RU
RU
RU
Sector System - 1900 Band C/F
Sector System - 1900 Band A/B/D/E
Sector System - 800
Sector System - 450 NMT A Sub Bnd
Sector System - 2100 Japan
SUB00xx
SUB00xx
SUB0028
SUB00xx
Mount SUB00xx
Assy
Cabinet AW Cabinet Package 19" Short
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 7 of 56
6/14/2006
AW 96 Series System Installation Manual
2.2 800 MHz Configurations
AW96R80AJ7A01
AW96R80AB3A01
AW96R80AJ3A01
AW96C80AJ3A01
AW10R80AF1A01
Assembly Part
Number
AW96R80AF7A01
Group
AW96R80AB7A01
High Level Model Structure Chart
(AW-96 Series 800 MHz Band Configurations)
AW96R80AA1A01
This model chart covers all 800 MHz (conventional Cellular band) configuration models.
Not all models are available in all markets. Clarify any model structure questions with
Technical Support Services or your Sales representative.
(Alt)
Name
Descripion
SUB0031
CDPB SUB00xx
Assy SUB00xx
CDPB
CDPB
CDPB
CPIB & PCPM 96 CE
CPIB & PCPM 32 CE (obsolete)
CPIB & PCPM PB Only
PBA0004
PBA0003
PBA0006
XCVB
XCVB
XCVB
XCVB
XCVB
XCVB
XCVB
XCVB
1.9 GHz Dual Mode 1/50mW PCS
800 Dual Mode 1/50mW Cell Band
450 Dual Mode 1/50mW NMT (A/H)
2100 MHz 1mW (Japan Band)
1800 MHz 1mW (Korea Band)
1.9 GHz xmit ONLY (PB)
800 MHz Xmit ONLY (PB)
SUB00xx
RCPB
SUB00xx
Assy
RCPB
RCPB
5.0 Watt Internal PA Module 1.9 GHz
5.0 Watt Internal PA Module 800 GHz
SUB00xx
FEDB SUB00xx
FEDB
FEDB
MiniCell Internal Duplexer 1.9 GHz
MiniCell Internal Duplexer 800 MHz
SUB00xx
SUB00xx
Chassis SUB00xx
Assy SUB00xx
SUB00xx
Chassis
Chassis
Chassis
Chassis
Chassis
AW-96 Chassis - Onmi Internal PA
AW-96 Chassis - Onmi/1S
AW-96 Chassis - 2 Sector
AW-96 Chassis - 3 sector
AW-10 Chassis - Pilot Beacon
External Cable Kit - Omni RU
External Cable Kit - Sector RU - S1
External Cable Kit - Sector RU - S2
External Cable Kit - Sector RU - S3
XCVB
SUB0004
Assy
SUB00xx
SUB00xx
SUB00xx
Ext
Cable
Kits
CBK0005
CBK0006
CBK0007
CBK0008
Ext Cable
Ext Cable
Ext Cable
Ext Cable
Cord
SUB00xx
Pwr Cord Power Cord UL 16 Guage
RU
RU
RU
RU
Omni System - 1900 Band C/F
Omni System - 1900 Band A/B/D/E
Omni System - 800
Omni System - 450 NMT A Sub-Band
RU Assy SUB00xx
SUB00xx
SUB0029
SUB00xx
SUB00xx
RU
RU
RU
RU
RU
Sector System
Sector System
Sector System
Sector System
Sector System
(Alt)
SUB00xx
SUB00xx
SUB0028
SUB00xx
Mount SUB00xx
Assy
- 1900 Band C/F
- 1900 Band A/B/D/E
- 800
- 450 NMT A Sub Bnd
- 2100 Japan
Cabinet AW Cabinet Package 19" Short
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 8 of 56
6/14/2006
AW 96 Series System Installation Manual
2.3 450 MHz (NMT Band) Configurations
CDPB
CDPB
CDPB
CPIB & PCPM 96 CE
CPIB & PCPM 32 CE (obsolete)
CPIB & PCPM PB Only
PBA0004
PBA0003
PBA0006
XCVB
XCVB
XCVB
1.9 GHz Dual Mode 1/50mW PCS
800 Dual Mode 1/50mW Cell Band
450 Dual Mode 1/50mW NMT (A/H)
XCVB
SUB0004
Assy
SUB00xx
SUB00xx
SUB00xx
XCVB
XCVB
XCVB
XCVB
2100 MHz 1mW (Japan Band)
1800 MHz 1mW (Korea Band)
1.9 GHz xmit ONLY (PB)
800 MHz Xmit ONLY (PB)
SUB00xx
RCPB
SUB00xx
Assy
RCPB
RCPB
5.0 Watt Internal PA Module 1.9 GHz
5.0 Watt Internal PA Module 800 GHz
SUB00xx
FEDB SUB00xx
FEDB
FEDB
MiniCell Internal Duplexer 1.9 GHz
MiniCell Internal Duplexer 800 MHz
SUB00xx
SUB00xx
Chassis SUB00xx
Assy SUB00xx
SUB00xx
Chassis
Chassis
Chassis
Chassis
Chassis
AW-96 Chassis - Onmi Internal PA
AW-96 Chassis - Onmi/1S
AW-96 Chassis - 2 Sector
AW-96 Chassis - 3 sector
AW-10 Chassis - Pilot Beacon
External Cable Kit - Omni RU
External Cable Kit - Sector RU - S1
External Cable Kit - Sector RU - S2
External Cable Kit - Sector RU - S3
Ext
Cable
Kits
CBK0005
CBK0006
CBK0007
CBK0008
Ext Cable
Ext Cable
Ext Cable
Ext Cable
Cord
SUB00xx
Pwr Cord Power Cord UL 16 Guage
RU
RU
RU
RU
Omni System - 1900 Band C/F
Omni System - 1900 Band A/B/D/E
Omni System - 800
Omni System - 450 NMT A Sub-Band
RU Assy SUB00xx
SUB00xx
SUB0029
SUB00xx
SUB00xx
RU
RU
RU
RU
RU
Sector System - 1900 Band C/F
Sector System - 1900 Band A/B/D/E
Sector System - 800
Sector System - 450 NMT A Sub Bnd
Sector System - 2100 Japan
SUB00xx
SUB00xx
SUB0028
SUB00xx
Mount SUB00xx
Assy
AW96C45AJ3A01
SUB0031
CDPB SUB00xx
Assy SUB00xx
AW96R45AJ3A01
Descripion
AW96R45AB3A01
Name
AW96R45AJ7A01
Assembly Part
Number
AW96R45AF7A01
Group
AW96R45AB7A01
High Level Model Structure Chart
(AW-96 Series 450 MHz Band Configurations)
AW96R45AA1A01
This model chart covers 450 MHz (former NMT Nordic Mobile Telephone band)
configuration models. Not all models are available in all markets. Clarify any model
structure questions with Technical Support Services or your Sales representative.
Cabinet AW Cabinet Package 19" Short
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 9 of 56
6/14/2006
AW 96 Series System Installation Manual
3 AW 96 & AW 10 Safety And Compliance Information
3.1 Statement Of Intent
The AirWalk AW 96 / AW 10 RAN is intended for use in a CDMA cellular infrastructure
radio access network. The responsible body shall be made aware that, if the equipment
is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
3.2 Safety Precautions
1) Power Sources
Use only power sources that are within the specified limits as designated on the
equipment labels. Use of power sources outside the specified limits is hazardous and
may cause personal injury or property damage.
2) Equipment Location
Equipment should be located indoors or in a suitable protected environment such as an
equipment enclosure. Use of unprotected equipment outdoors is hazardous and may
cause personal injury or property damage.
3) Grounding And Electrical Connections
Electrical connections including equipment grounding should be made in accordance with
the National Electric Code and any local regulations. Improper electrical connections are
hazardous and may cause personal injury or property damage. Consult a licensed
electrical installer if in doubt.
4) Hazardous Voltages
Equipment may contain hazardous voltages. Only qualified service personnel should
open the equipment for adjustments, repairs or replacements.
5) Replacement Parts
Damaged parts and protective devices such as fuses should only be replaced by
components approved or recommended by AirWalk Communications. Replacement
fuses must be of the same rating and type as the original for continued protection.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 10 of 56
6/14/2006
AW 96 Series System Installation Manual
3.3 Maintenance Information
3.3.1 Cleaning
The AirWalk AW 96 / AW 10 units are protected by a high performance paint which does
not require normal maintenance. If paintwork is soiled, it can be cleaned using a damp
cloth after AC power has been disconnected. Do not use liquids or spray cleaning
substances on the unit since property damage or personal injury may result.
3.3.2 Filter Maintenance
The AW 96 / AW 10 Main Unit is equipped with a washable air filter located in a front
mounted drop down door.
This filter should be checked annually for dirt build-up and cleaned if required. Note more
frequent inspections may be needed in dusty environments.
Air Filter Located In
Drop Down Front Door
3.3.3 Fuse Replacement
The AW 96 Main Unit contains a 250 V 5A fuse located behind the AC connector cap as
shown in the diagram. Replace the fuse with the same type and ratings.
Removable
Fuse Cap
3.3.4 Other Maintenance
Any other required maintenance must be performed by suitable trained service personnel.
Do not open covers or attempt to repair unit if not suitably trained.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 11 of 56
6/14/2006
AW 96 Series System Installation Manual
3.4 Labeling
3.4.1 Grounding
Proper grounding is recommended to ensure good RF performance in addition to
personnel safety. Antenna systems should also be suitably grounded for good RF
performance.
Grounding connection points on the chassis are identified by this symbol:
3.4.2 Label: Model Identification, FCC Identification, Power
The following label is applied to the AW 96 unit to provide model identification, FCC
identification and rated power supply information (sample label shown).
1.0
15.0
IP-Base Station
Model : AW96R19AJ1A01 FCC ID : R4HAW96R19AJ1A01
S/N :
*ZF000096UA*
AC IN: 100-240 VAC 50/60Hz 6A/3A
Fuse: AC 250V 6A (20mm x 5mm)
AirWalk Communications., Inc Contact: +1-972-638-9400
50.0
Made In U.S.A.
76.0
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 12 of 56
6/14/2006
AW 96 Series System Installation Manual
3.5 Regulatory Compliance Information
The FCC regulatory compliance information provided in this section is applicable only to
models equipped with an FCC identification number (FCC ID).
3.5.1 Radio Interference (FCC 15.19 Statement)
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
3.5.2 Unauthorized Modifications (FCC 15.21 Statement)
Persons or parties responsible for operation of this equipment are cautioned that any
changes or modifications not expressly approved by AirWalk Communications
Incorporated could void the user’s authority to operate this equipment.
3.5.3 Digital Device Interference (FCC 15.105 Statement)
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications.
3.5.4 RF Exposure (FCC MPC Compliance)
In order to comply with FCC RF Exposure requirements, this device must be installed
and operated in such a way that a minimum separation distance of 20 cm is always
maintained between the antenna and all persons during normal operations.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 13 of 56
6/14/2006
AW 96 Series System Installation Manual
AW 96 / AW 10 System Introduction
4.1 Overview
The AirWalk AW 96 MiniCell / AW 10 Pilot Beacon (CDMA-2000 IP-Base Station) product
are unique in that both BTS and BSC functionality are combined in one compact platform.
This product is designed for efficiency and optimized to reduce the service providers
CAPEX, and OPEX and at the same time, it increases the number of users per assigned
spectrum.
It provides higher capacity in less space for today’s spectrum hungry data and multimedia applications.
The AW 96 system provides the following advantages:
•
Compact Omni system in a single package
•
Supports 2G (TIA/EIA-95, J-STD-008) and 3G-1X (CDMA2000) standards
•
Supports data service transmission of 1.2 kbps to 144 kbps (AW 96 MiniCell)
•
Provides 96 basic channel elements (AW 96 MiniCell)
•
Multi-Carrier (hopping) Pilot Beacon capability (AW 10 Pilot Beacon)
•
Easy repair and support
•
Provides an ‘All-IP’ solution
•
Provides an effective solution for enterprise networks and hot spots.
4.2 IP- Base Station (BS) System Description
The AW 96 IP-RAN (Internet Protocol Radio Access Network) is composed of two main
modules: The IP based BSC and the IP based BTS. When an AirWalk IP-RAN is
installed in an ‘ALL-IP’ network the integrated BTS is controlled by the integrated BSC,
and the integrated BSC is controlled by a SS (Soft Switch). Legacy Switching Systems
can also control the integrated BSC through standards based interfaces.
SS7 Network
SMSC
MultiMedia
Multi-Media
Internet
HLR
SG
Wireless
Core Network
MSC
BSC
Macro Network
PDSN
Softswitch
OAM
Core IP Network
Micro Network
MG
IP- RAN
IP- RAN
(BSC+
(BSC+ BTS)
BTS)
PSTN
Figure 4-1 Network Diagram
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 14 of 56
6/14/2006
AW 96 Series System Installation Manual
4.3 Hardware Configuration
The IP-BS is a unique modular and stackable combination BSC and BTS platform that is
differentiated from other systems. Other systems have separate BTS and BSC platforms
which adds to cost and complexity. The AirWalk RAN has a structure that combines and
arranges the BSC interface with one the BTS in a single package.
The main components are (depending on specific model):
•
AW-96 MiniCell
o CDPB (Common Digital Processing Board), consisting of:
ƒ CPIB (Channel Processor and IF Interface Board)
ƒ PCPM (Primary Call Processor Module)
ƒ GPSR (Global Positioning System Receiver)
o XCVB (RF Transceiver Board)
o PSA (Power Supply Assembly)
o RCPB (RF Power amplifer Board) 4 Watt CDMA Power Amplifier
o FEDB (Front End/Duplexer Board) Duplexer & Antenna Interface
•
AW-10 Pilot Beacon
o CDPB (Common Digital Processing Board), consisting of:
ƒ CPIB (Channel Processor and IF Interface Board) PB Only
ƒ PCPM (Primary Call Processor Module)
ƒ GPSR (Global Positioning System Receiver)
o XCVB-SP (RF Transceiver Board) Transmit Only configuration
o PSA (Power Supply Assembly)
o RCPB (RF Power amplifier Board) 4 Watt CDMA Power Amplifier
4.3.1 Physical Description
•
AW 96 MiniCell / AW 10 Pilot Beacon
o Dimension: Max. 482mm(W) x 457mm(D) x 178mm(H)
o 19” EIA Rack x 4 Rack Units
o Weight: 18 kg (3 Sector); 15 kg (Omni)
4.3.2 Typical Configurations
The following shows typical component configurations for common applications. Refer to
the model charts for the contents of specific model numbers.
Omni medium power (4 Watt) MiniCell base station
- AW 96 MiniCell self contained unit
Omni Macrocell Pilot Beacon System (4w PPS)
- AW 10 Pilot Beacon self contained unit
Omni Multi-Carrier Macrocell Pilot Beacon System (4w PPS, 3 carrier hopping)
- AW 10 Pilot Beacon self contained unit with Multi-Carrier software option
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 15 of 56
6/14/2006
AW 96 Series System Installation Manual
4.3.3 Installation Photographs
The following photographs show typical field installations for AW 96 MiniCell and AW 10
Pilot Beacon systems:
Figure 4-2 – Typical AW 96 MiniCell & AW 10 Pilot Beacon System
Figure 4-3 – Typical AW 96 MiniCell / AW 10 Pilot Beacon Rack Mounted
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 16 of 56
6/14/2006
AW 96 Series System Installation Manual
4.4 Block Diagram – AW 96 MiniCell / AW 10 Pilot Beacon
To
RCPB
PSA
GPSR
CPIB
RCPB
XCVB
IF I/F - α
(A/D & D/A)
Processor
(MPC8250)
FPGA
(Control
Logic)
HPAU
(4/8Watt)
UPCB
IF I/F - β
(A/D & D/A)
DPL
FEDB
DNCB
CSM5K
X3
Duplexer
IF I/F - γ
(A/D & D/A)
From/To
Antenna
PCPM
Processor
(MPC8260)
Memory Block
Gateway I/F
From/To
CA & WPM
Figure 4-6 AW 96 / AW 10 Hardware Structure
AW 10 Pilot Beacon Notes:
FEDB not provided on AW 10 models
AW 10 XCVB may not be equipped with diversity receiver
AW 10 CPIB may not be equipped with 3 CSM-5000 or receiver A/D & IF
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 17 of 56
6/14/2006
AW 96 Series System Installation Manual
4.5 System Capacities and Specifications
4.5.1 AW 96 Technical Specification
Item
Frequency Band
Capacity and
Specification
Up-Link: 1850 ~ 1910 MHz
Down-Link: 1930 ~ 1990 MHz
Up-Link: 824 ~ 849 MHz
Down-Link: 869 ~ 894 MHz
1FA/Omni
3FA Hopping Pilot Beacon
Channel Elements / IP-BS 96CE
Handoff
Softer H/O, soft H/O. Hard H/O
Diversity Receiver
2 branch with imbalance alarm
GPS
External GPS Antenna
Installation
Rack Mountable
Cooling
Forced Air
IP-Network Interface
10/100 Base-T Ethernet
Transmitter output power
4W Internal RU system
Antenna A (Tx/RxA)
RF Interface
Antenna B (RxB)
J-STD-008/IS-95-A/IS-95B
Common Air Interface (CAI)
/CDMA2000-1x
Channel bandwidth
1.25MHz
Less than 1% FER, when the
Receiving sensitivity
power is under -119dBm
FA
Remarks
North American PCS Band
800 MHz Cellular Band
Each AW 96 / AW 10 Unit
AW 96 MiniCell
AW 96 MiniCell
One per AW-96 / AW 10
4 Rack Units
Front To Rear Flow
Includes duplexer (MiniCell)
CDMA 2000 1x
AW 96 MiniCell
Mechanical Specification
RF Input and Output
Connector
AC Power Connector
Ethernet Signal Port
Connectors
Dimensions ( W x H x D )
Weight
SMA Female (Input/Output)
From/To Antenna System
IEC
RJ-45
482mm(W) x 457mm(D) x
178mm(H)
20 kg
4 Rack Units
AW 96 / AW 10
Table 4-1 – AW-96 MiniCell / AW 10 Pilot Beacon Specifications
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 18 of 56
6/14/2006
AW 96 Series System Installation Manual
4.5.2 IP-BS Power Supply & Environment Technical Specification
Input Power Supply
Input Voltage:
Input Frequency:
AC 100Volts ~ 250Volts
50Hz ~ 60Hz
Dissipated Power
AW-96 Main Unit:
350 Watt Max (Efficiency 75%)
Environment Specification
Operating Temperature
Storage Temperature
Relative Humidity
Noise
Airborne Particle
0o ~ +50 o
-30 o ~ +60 o
5% ~ 95% - Non-condensing
Less than 60dBA, distance 1.5m
0 ~ 90 ㎍/㎥
Table 4-3 - Power Supply & Environment Specifications
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 19 of 56
6/14/2006
AW 96 Series System Installation Manual
5 AW 96 MiniCell / AW 10 Pilot Beacon Components
5.1 AW-96 / AW 10 Main Unit
Figure 5-1 AW-96 Main Unit Photo (Front View)
RCPB
FEDB
XCVB
PSU
CDPB
Figure 5-2 AW-96 Main Unit Line Diagram (Front View)
FEDB: AW 96 MiniCell Only
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 20 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 5-3 AW-96 Main Unit Photo (Back View)
Figure 5-4 AW-96 – Line Diagram (Back View)
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 21 of 56
6/14/2006
AW 96 Series System Installation Manual
5.2 Component LED Configuration
CDPB: LED status indicators are provided on the AW-96 CDPB module. LED functions
are described in the following pictures and tables.
PWR
CDPB
FLT
BTS
MMI
CPIB
GPSR
BSC
MMI
RESET
CPIB
PCPM
PCPM
SCPM
SCPM
Figure 5-9 CDPB Panel Diagram
Figure 5-10 - CDPB Panel Photo
Name
Color
On
Off
Note
CPIB
GPSR
PCPM
SCPM
Green
Green
Green
Green
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Abnormal
CPIB
Orange
Abnormal
Normal
GPSR
Orange
Abnormal
Normal
PCPM
Orange
Abnormal
Normal
SCPM
Orange
Abnormal
Normal
CPIB power on/off indicator
GPSR power on/off indicator
PCPM power on/off indicator
SCPM power on/off indicator
Check function of CPU in CPIB
Board and ALARM
GPSR alarm on/off indicator
Check function of CPU in
PCPM Board and ALARM
Check function of CPU in
SCPM Board and ALARM
Table 5-1 – CDPB Indicator Codes
NOTE: AW-96 / AW 10 models are NOT normally equipped with an SCPM (Secondary
Call Processor Module), therefore these indicators are not used in most system
applications.
XCVB: The XCVB module is equipped with 2 indicators. LED functions are described in
the following pictures and tables.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 22 of 56
6/14/2006
AW 96 Series System Installation Manual
XCVB
PWR
FLT
Figure 5-11 - XCVB Panel Diagram
Figure 5-12 XCVB Panel Photo
Name
PWR
FLT
Color
On
Green
Orange
Off
Normal
Abnormal
Abnormal
Normal
Note
XCVB power on/off indicator
XCVB alarm on/off indicator
Table 5-2 - XCVB Indicator Code Key
RCPB: The RCPB module is equipped with 2 indicators. LED functions are described in
the following pictures and tables.
RCPB
PWR ACT/FLT
Figure 5-13 - RCPB Panel Diagram
Figure 5-14 RCPB Panel Photo
Name
PWR
ACT/FLT
ACT/FLT
Color
Green
Green
Orange
On
Off
Note
Normal
Normal
Abnormal
Abnormal
(power off)
(power off)
RCPB power on/off indicator
RCPB alarms are clear
RCPB alarm/fault
Table 5-3 - RCPB Indicator Code Key
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 23 of 56
6/14/2006
AW 96 Series System Installation Manual
6 AW 96 / AW 10 Interface Cabling
6.1 RF Cabling – AW 96 MiniCell
The AW 96 MiniCell Antenna ports are connected to the external diversity antenna
systems as shown in Figure 6.1 (cables not included). External connectors are SMA type.
In a non-diversity application, connect the antenna system to the main antenna port. Note
the internal duplexer function provides a duplexed TX/Rx connection at the main antenna
port (marked Txα on some enclosures).
Antenna systems must include suitable protection against lightning and other hazards in
accordance with conventional cell site installation practices.
To Diversity
Antenna
GPSANT
T_EVEN RF RXB(a)
RF RXA(a) RF TX (a)
T_10MHz RF RXB(b)
RF RXA(b) RF TX(b)
RF RXB(r)
RF RXA(r) RF TX (r)
RU IF
BSC IF
ENV IF
BTS IF
To Main
Antenna
Figure 6-1 AW 96 MiniCell RF Cabling Diagram
6.2 RF Cabling – AW 10 Pilot Beacon
The AW 10 Pilot Beacon Antenna port is connected to the external antenna system as
shown in Figure 6.2 (cables not included). External connector is SMA type.
The AW 10 Pilot Beacon is not equipped with any receivers, therefore there is no
duplexer requirement for normal operation. Note the main antenna port may be marked
Txα on some enclosures.
Antenna systems must include suitable protection against lightning and other hazards in
accordance with conventional cell site installation practices.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 24 of 56
6/14/2006
AW 96 Series System Installation Manual
GPSANT
T_EVEN RF RXB(a)
RF RXA(a) RF TX (a)
T_10MHz RF RXB(b)
RF RXA(b) RF TX(b)
RF RXB(r)
RF RXA(r) RF TX (r)
RU IF
BSC IF
ENV IF
BTS IF
To Main
Antenna
Figure 6-2 AW 10 Pilot Beacon RF Cabling Diagram
6.3 Ethernet/Serial Cable Wiring (AW 96 / AW 10)
Connect the external Ethernet connections (cable not supplied) from the local Ethernet
switch or hub at the cell site to the BTS and BSC Ethernet ports on the AW-96 /AW 10 as
shown in Figure 6.3. Use category 5 Ethernet cable (or better) for best performance.
6.4 Electric Power Cable Wiring (AW 96 / AW 10)
Connect AW-96 /AW 10 to suitable AC power sources as shown in Figure 6-3. Use only
the AC power cables provided with AW 96 / AW 10 unit to ensure continued safe
operation.
GPSANT
T_EVEN RF RXB(a)
RF RXA(a) RF TX (a)
T_10MHz RF RXB(b)
RF RXA(b) RF TX(b)
RF RXB(r)
RF RXA(r) RF TX (r)
RU IF
BSC IF
ENV IF
BTS IF
To Local
Ethernet
Switch/Hub
AC
Power
Figure 6-3 AW 96 / AW 10 Power & Ethernet Cabling
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 25 of 56
6/14/2006
AW 96 Series System Installation Manual
6.5 Photograph Of Typical Cable Wiring
Figure 6-4 shows the actual cabling found in a typical system installation.
Figure 6-4 – AW 96 MiniCell Field Installation Photograph
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 26 of 56
6/14/2006
AW 96 Series System Installation Manual
7 Frequency Setting Procedures
7.1 BSM Management
The AW-96 series base stations are normally managed by the centrally located BSM
(Base Station Manager) system which communicates with the AW-96 over an IP
connection.
The BSM will download system software and configuration information which includes the
physical FA (Frequency Assignment) for each base station. The base station will tune to
the correct frequency as defined by the BSM configuration files.
Refer to the BSM operations manual for instructions on base station remote configuration.
7.2 Local FA Setting
It may required to set the AW-96 series base station physical FA (frequency assignment)
locally for specialized test purposes or when the BSM connection is unavailable (for
example during early BTS installations). This can be done using the local MMI (Man
Machine Interface) port and a local PC.
The configuration data downloaded from the BSM will override local settings when BSM
connections are established.
Refer to the MMI instruction manual for further information on other commands.
7.2.1 MMI Connection
Connect the serial port of the PC to the “BTS MMI” port on the AW-96 front panel. Use
the cable described in section 8.3.1 and the following port settings:
9600 baud
8 bit
No Parity
1 stop bit
No flow control
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 27 of 56
6/14/2006
AW 96 Series System Installation Manual
7.2.2 FA Change Procedure
The following menu driven commands will permit local change of the FA.
Step 1
At the prompt enter the following:
> pn3383
// this will take you to the menu screen which looks something like this:
================= PN 3383 ====================
1. Tx Test
2. Rx Test
3. ParameterSetup
4. Rf Gain Display
5. xcvbSetup
6. ampSetup
7. Normal Gain Display
8. MakeTestCall
9. callClear
10. Overhead Calibration Control
11. Test Phone Setup (619 2221001)
12. Handoff Test
0. Exit
-------------------------------------------------Select Number ===>
Step 2
Enter the following:
Select number => 5
// it will take you to the below menu screen.
================= Xcvb Setup ====================
1. Change Ch
2. Tx On
3. Tx Off
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 28 of 56
6/14/2006
AW 96 Series System Installation Manual
4. Rx_Main_AGC ON
5. Rx_Main_AGC OFF
6. Rx_Sub_AGC ON
7. Rx_Sub_AGC OFF
8. Set RxMain ATT
9. Set RxSub ATT
10. Set Tx Att
11. Xcvb Status
12. showXcvrAttGain
0. Exit
-------------------------------------------------Select Input Number =====>
Step 3
Enter the following:
Select Input Number => 1 // choosing 1 will take you to the below menu.
ALPHA : xcvrChangeCh Num [001 ~ 1500] [1175] [/0:Exit]==>
Step 4
From the above menu, type the new channel desired (CDMA channels from 1 to 1500)
and 0 to exit. Note that for 3 sector base stations Step 3 must be repeated for each
sector (alpha, beta, and gamma).
Note that only standard CDMA channel numbers within the designated band capability of
the radio will be accepted by the base station.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 29 of 56
6/14/2006
AW 96 Series System Installation Manual
8 Installation Procedures
This Section gives definitions and instructions for installing the AW-Series IP-RAN and for
connecting it to the wireless carriers infrastructure. It contains detailed definitions needed
for completing site Installation Checklist (Appendix B).
8.1 Installation Verification
Before installing the equipment, it is necessary to verify the following:
8.1.1 Verify Customer Contact & Equipment location
8.1.1.1 Contact Customer1
1) Verify contact name check Site Preparation Planning Checklist Appendix B.
2) Verify contact phone number.
3) Introduce yourself to the Customer contact.
4) Introduce Installation team (if more than one person on team).
5) Verify that all current customer contacts are listed.
a) Verify that contacts can solve problems within a timely manner for:
i) Power Connection(s),
ii) T1 Connection(s),
iii) LAN Connection(s),
iv) If not, have main customer contact provide names and method of
contacting.
6) Determine when contacts are available for help (e.g.; Time of day, day of week.).
7) Obtain any site access or security requirements (e.g.: ID Badges, Card-keys, Keys,
Access codes) required to access installation site.
8) Indicate all changes on checklist.
8.1.1.2 Locate AW-SERIES IP-RAN Equipment.2
1) Determine where AW-SERIES IP-RAN is stored.
2) Check for any visible shipment damage.
NOTE: Make sure all changes are sent to the Installation Coordinator Immediately.
NOTE: If any visible damage contact the Installation Coordinator immediately.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 30 of 56
6/14/2006
AW 96 Series System Installation Manual
8.1.1.3 Locate and verify floor space.
1) Determine where the AW-SERIES IP-RAN is to be installed (Refer to site diagram
in Appendix B).
2) Verify that there is enough space to safely install it (Refer to site diagram in
Appendix B).
8.1.2 Uncrate and arrange for packing material disposal
1) Carefully unpack the AW-SERIES IP-RAN and related components from packing
material.
2) Check for any shipment damage.3
3) Be certain that all components match system order.4
4) Make arrangements with customer contact on where, when, and how to dispose of
all AW-SERIES IP-RAN packing material.
8.1.3 Verify location of all Facility distribution points
(main and intermediate)
8.1.3.1 Power Check.
8.1.3.1.1 Power Location
1) Locate the customer provided power connection.
a) There should be a –48VDC connection for DC powered models (if required).
b) There should be a 120 or 240 VAC connection for AC powered models (if
required).
8.1.3.1.2 Verify Connector.
1) An 8 AWG three wire stranded cable to connect to a WECO DC terminal block
connector is required for –48VDC (if required).
2) A 6ft (1.84m) e conductor type SJT cables with standard grounded connector is
required for 110VAC connection (if required).
NOTE: Note any damage on shipping report, and Installation Checklist. Contact
the Installation Coordinator immediately
NOTE: If components do not match the system order, contact the Coordinator
immediately.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 31 of 56
6/14/2006
AW 96 Series System Installation Manual
8.1.3.1.3 Voltage
1) Using a power meter check for correct voltage.
a) –48VDC range is 40VDC to 57VDC (if required).
b) 120 VAC range is 90 VAC to 132 VAC (if required).
c) 240 VAC range is 180 VAC to 264 VAC (if required).
8.1.3.1.4 Amps
1) Check cables to determine if they will handle required Amps.
a) –48VDC should be able to support 27.9 Amps.
b) 120 VAC should support 15 Amps, 240 VAC should support 7.5 Amps
8.1.3.1.5 LAN Facilities check.
1) Location – Locate the customer provided LAN connections.
2) Verify IP Address (Site Prep Checklist Appendix B).
3) Verify Connector is an RJ45 (if not contact customer).
4) Connect Laptop and Ping IP Address.
5) Prepare a site IP addressable device diagram showing the IP address for each
device at the base station site. This diagram is essential for any needed
troubleshooting activities.
6) Post the diagram at the site and return a copy to the customer’s maintenance center
and a copy to the AirWalk customer service center:
AirWalk Customer Service Centre
1830 North Greenville Ave.,
Richardson, Texas 75081
8.2 AW-SERIES IP-RAN Install Procedures
8.2.1 Install AW-SERIES IP-RAN Cabinet
Move AW-SERIES IP-RAN to location.
Secure AW-SERIES IP-RAN in designated location
(Bolt down or Secure Wheels if provided).
8.2.2
Verify All Internal System Connections
To verify all internal connections refer to the Section and Figures in the following Table
for proper cable installation. This section not applicable to AW 96 MiniCell / AW 10 Pilot
Beacon products
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 32 of 56
6/14/2006
AW 96 Series System Installation Manual
Section
6.1
6.3
Description
RF Cable - AW-96 RU
Ethernet Cable – AW-96 to RU
Reference
N/A
N/A
Table 7-1 - Internal System Cable Reference
8.2.3 External System Connections5
To install new internal connections refer to the Section and Figures in the following Table
for proper cable installation.
Section
Description
Reference
6.1
External Diversity Antenna System
Figure 6-2
Figure 6-3
6.2
Electrical Power Cable
Use AC power
cables supplied
with AW-96.
6.3
6.4
External BSC & BTS Ethernet Cable
External GPS Antenna Cable
Figure 6-4
Figure 6-5
Table 7-2 - External System Cable Reference
8.2.4 Connect Power to Cabinet
Connect -48VDC to DC distribution panel (if applicable).
Connect 120VAC or 240VAC to Rack AC distribution panel (if applicable).
8.2.5 Connect Communications Facilities
Connect LAN Facilities to BSC
Connect LAN Facilities to BTS.
WARNING: Make sure all system power supplies are turned off. All
breakers/Fuses are pulled on all main and intermediate panels. Then proceed with
the Installation.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 33 of 56
6/14/2006
AW 96 Series System Installation Manual
8.2.6 Power-up procedure67
8.2.6.1 Power-up Main cabinet.
Make sure all appropriate LED’s are illuminated.
8.2.6.2 Complete any Configuration options.
a) Configure the AW-SERIES IP-RAN.
i)
Outgoing and incoming channels.
8.3 System Test
This section contains the system tests that should be completed to determine if AWSERIES IP-RAN is operational.
8.3.1 PC to AW 96 cable
A special cable is required to run the required certification tests.
Connect a PC with the subject cable to run tests
RJ1
Pin Configuration
P1
RJ-45
10
10
BTS
DB9
(Computer)
RJ-45
(BTS)
CONNECTOR DB9
Figure 7-1 - PC to AW 96 Cable Specifiaction
Note: Once all connections are made, make sure to: Reset/install all breakers/fuses for
all main and intermediate breaker/fuse box(s). Then proceed with the Installation.
Make sure all added cabling is tie-wrapped correctly
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 34 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 7-2 - PC to AW 96 / AW 10 Cable Connection Diagram
8.3.2 System Certification Tests
Start The AW-SERIES IP-RAN tests.
This sequence of test cases is designed to certify the AW 96 IP-RAN installation.
It is assumed the person running this checklist is familiar with the basics of configuring,
running, stopping, and starting the AW 96 IP-RAN.
8.3.2.1 Test Case #1 - Image/PLD loading
8.3.2.1.1 Test Procedure #1
•
Command:
user: ipbs001
FTP password: ipbs001
•
Command:
Edit:
- P: display
- C: edit
8.3.2.1.2 Expected Result of Case #1
Screen from PC using ftp Server is shown in Figure 7-3.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 35 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 7-3 - Screen from PC Screen from WPM
Figure 7-4 - Screen from PC
8.3.2.2 Test Case #2 – System Check
8.3.2.2.1 Test Procedure #2
•
Command: Version
8.3.2.2.2 Expected Result of Case #2
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 36 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 7-5 - Version Command Screen
8.3.2.3 Test Case #3 – Tx check
8.3.2.3.1 Test Procedure #3
•
Command: txReason
•
Expected Result of Case #3
Figure 7-6 - Tx Check Screen
8.3.2.4 Test Case #4 – Output power
8.3.2.4.1 Test Procedure #4 – RF Check
•
Command: showRfGain
8.3.2.4.2 Expected Result of Case #4
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 37 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 7-7 - RF Check Screen
8.3.2.5 Test Case #5 – GPS Check
8.3.2.5.1 Test Procedure #5
•
Command: gpsStatus
8.3.2.5.2 Expected Result of Case #5
Figure 8-8 – GPS Status Check Screen
Figure 8-9 - GPS Alarm Check Screen
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 38 of 56
6/14/2006
AW 96 Series System Installation Manual
8.3.2.6 Test Case #6 – BTS Alarm Check
8.3.2.6.1 Test Procedure #6
•
Command: showAlarm
8.3.2.6.2 Expected Result of Case #6
Figure 8-10 - BTS Alarm Check Screen
8.3.2.7 Test Case #7 – System Reset
8.3.2.7.1 Test Procedure #7
•
Command: btsReset/bscReset/allReset
8.3.2.7.2 Expected Result of Case #7
The system is RESET
8.3.2.8 Test Case #8 – PN Check
8.3.2.8.1 Test Procedure #8
•
Command: RcmCmd 1,1
8.3.2.8.2 Expected Result of Case #8
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 39 of 56
6/14/2006
AW 96 Series System Installation Manual
Figure 8-11 - PN Check Screen
8.3.2.9 Test Case #9 – System Interface Check
8.3.2.9.1 Test Procedure
•
Command: Ping
Send Ping Command to the Following system IP Addresses
1. WPM (Wireless PBX Manager)
2. PDSN (Packet Data Serving Node)
3. CA (Call Agent)
4. MG (Media Gateway)
5. SG (Signal Gateway)
8.3.2.9.2 Expected Result of Case #X
A successful PING command response from each system.
8.3.3 Operation Tests
These test cases are designed to determine if AW 96 is ready for production testing.
8.3.3.1 Test Case #1 – Voice Calls
8.3.3.1.1 Test Procedure
Test Call From MS #1 to MS #2.
Test Call From MS #1 to Landline Phone #1.
8.3.3.1.2 Excepted Result of Case #1
1. 2nd MS Rings and call is answered
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 40 of 56
6/14/2006
AW 96 Series System Installation Manual
2. Landline phone Rings and call is answered.
8.3.3.2 Test Case #2 – Data Calls
8.3.3.2.1 Test Procedure
1. A Test Data Call From MS #1 to MS #2.
2. A Test Data Call From MS #2 to MS #1.
8.3.3.2.2 Excepted Result of Case #2
1. A Data Session is established between MS #1 and MS #2.
2. A Data Session is established between MS #2 and MS #1.
8.3.4 Operator Specific Tests
These test cases are covered in a separate test plan document and are agreed to by the
operator and AirWalk Communications, Inc.
8.4 Site Clean up and Customer Signoff
8.4.1 Dispose of all packing material.
Make sure to dispose of all AW-SERIES IP-RAN packing material.
8.4.2 Clean-up site.
Make sure not to leave anything but the installed AW-SERIES IP-RAN. (e.g., excess tiewraps, bolts, etc).
8.4.3 Update Installation Checklist.
Make sure all changes are notes on Installation Checklist.
8.4.4 Customer Signoff.
Get Customer Signature on Certification Document Appendix D.
8.5 Required Tools and Supplies
1) Hand Tools
a) Screwdriver set,
b) Pliers set,
c) Nut Driver set,
d) Cutter set,
e) Punch Down Tool,
f)
Wire-wrap (Optional),
g) RJ-45 Crimper.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 41 of 56
6/14/2006
AW 96 Series System Installation Manual
2) Test Equipment.
a) Multi-Meter & Adapter kit,
b) Cable Tester,
c) Protocol Analyzer & Adapter kit,
d) Telephone Test Set (Butt-set),
e) Set of Banjo adapters
f)
Tone Generator & Inductive pick-up.
3) Supplies.
a) RJ-45,
b) Cat 5 Cable,
c) Tie-wraps.
8.6 Troubleshooting Procedures
The AW-SERIES IP-RAN is designed to provide reliability and consistently high
performance in all network environments. The installation procedure for the AW-SERIES
IP-RAN is a straightforward and is discussed in these sections.
Should problems develop during installation, this section is intended to help locate,
identify and correct these types of problems. Please follow the suggestions listed below
prior to contacting AirWalk Communications, Inc. or Carrier contacts. If you are unsure of
the procedures described in this section, contact the Installation coordinator immediately.
8.6.1 Before Calling for Assistance
1) If difficulty is encountered with a specific component of the AW-SERIES IP-RAN,
refer back to the Installation Section for that component.
2) Check the cables and connectors to ensure that they have been properly connected
and the cables/wires have not been crimped or impaired in some way during
installation. (About 90% of component problems can be attributed to wiring and
connector problems).
a) Check Cable,
b) Check connector,
c) Check for solid connection,
d) Check with Carrier contact.
3) Make sure that all power cord is properly attached to each AW-SERIES IP-RAN
component. Be certain that all power cords are plugged into a functioning electrical
outlet. Use the PWR LED’s to verify each unit is receiving power.
a) Check intermediate breakers or fuses.
4) If the problem is isolated to something other than the AW-SERIES IP-RAN contact
the appropriate Carrier contact.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 42 of 56
6/14/2006
AW 96 Series System Installation Manual
5) Verify whether or not the problem is corrected. If not, go to Step 6 below. If the
problem is corrected, continue with installation.
6) If the problem continues after completing Step 4 above, contact the AirWalk
Communications, Inc. Installation Project manager, to determine the next course of
action.
8.6.2 When Calling for Assistance
Please be prepared to provide the following information.
1) A complete description of the problem, including the following points:
a) The nature and duration of the problem;
b) Situations when the problem occurs;
c) The components involved in the problem;
d) Any particular application that, when used, appears to create the problem;
2) A record of changes that have been made to the AW-SERIES IP-RAN configuration
prior to the occurrence of the problem.
3) Any changes to system should all be noted.
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 43 of 56
6/14/2006
AW 96 Series System Installation Manual
9 Appendix A - Acronyms
Acronym
2G
3G
AC
Access
Channel
ACH
AD
AFEU
AGC
ANT
AWGN
Base Station
(BS)
BCCM
BHCA
BLK
BS
BSAP
BSC
BSMAP
BTS
CA
CAI
CC
CCM
CDMA
CEC
CED
CLAP
CPIB
CPU
CR
CREF
CSM5000
DA
DC
DCCH
DCLI
DRS
DT
Description
Second Generation in CDMA wireless network
Third Generation in CDMA wireless network
Alternating Current
A Reverse CDMA Channel used by mobile stations for communicating to the
base station. The Access Channel is used for short signaling message
exchanges, such as call originations, responses to pages and registrations. The
Access Channel is a slotted random access channel.
Access Channel
Analog to Digital
Antenna Front End Unit
Automatic Gain Control
Antenna
Additive White Gaussian Noise
A fixed station used for communicating with mobile stations. Depending upon
the context, the term base station may refer to a cell, a sector within a cell, an
MSC, or other part of the wireless system.
BTS Call Control Module
Busy Hour Call Attempts
Blank
Base Station
Base Station Application Part
Base Station Controller
Base Station Management Application Part
Base station Transceiver Subsystem
Call Agent
Common Air Interface
Connection Confirm
Channel Control Module in BTS
Code Division Multiple Access
Channel Elements Control Block
Channel Elements Diagnostic Block
Composite Link Analysis Platform
BTS Channel and Call Processing Interface Board
Central Processing Unit
Connection Request
Connection Refused
Cell Site Modulator 5000 (CDMA ASIC chip released by Qualcomm for
cdma2000)
Digital to Analog
Direct Current
Dedicated Control Channel
Data Link Connection Identifier
Data Ready to Send
Data Form
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 44 of 56
6/14/2006
AW 96 Series System Installation Manual
Acronym
DTAP
EMI
ESN
EVDO
EVDV
EVRC
FA
FCC
F-CCH
FCH
F-DCCH
FDCH
FER
FM
FO
Forward
Traffic
Channel
FSCH
GND
GPS
GRE
HLR
HO
HPAU
IF
IMSI
ING
IOS
IP
IPC
LAC
LPA
LTU
MAC
MAHHO
MCC
MG
MIMO
MIN
MMC
MMS
MN
Description
Direct Transfer Application Part
Electro-Magnetic Interference
Electronic Serial Number
Evolution Data Only
Evolution Data and Voice
Enhanced Variable Rate CODEC
Frequency Assignment
Federal Communications Commission
Forward Common Control Channel
Fundamental Channel
Forward Dedicated Control Channel
Forward Dedicated Signaling Logical Channel
Frame Error Rate
Fault Management
Frame Offset
One or more code channels used to transport user and signaling traffic from the
base station to the mobile station.
Forward Common Signaling Logical Channel
Ground
Global Positioning System
Generic Routing Encapsulation
Home Location Register
Handoff
High Power Amplifier Unit
Intermediate Frequency
International Mobile Subscriber Identity
Inter Network Gateway
Interoperability System
Internet Protocol
Inter Processor Communication
Link Access Control.
Entity that provides assured mode or unassured mode delivery of information
across the air interface between the mobile station and the base station.
Linear Power Amplifier
Logical Transmission Unit
One or more Type 3 or Type 5 MuxPDUs with a 16bit CRC.
Medium Access Control
Entity that controls the access to and from Upper Layer Signaling, Data Services
and Voice Services to Physical Layer resources.
Mobile Assisted Hard Hand Off
Main Call Control module in IP-BSC
Media Gateway
Multi Input Multi Output
Mobile Identification Number
Man-Machine Command
Multimedia Messaging Service
Mobile Node
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 45 of 56
6/14/2006
AW 96 Series System Installation Manual
Acronym
MS
MSC
MTBF
MTTR
NDSS
NGN
NMS
OAM
OCNS
OS
OTD
OUNS
PACA
Paging
Channel
PBA
PBX
PCB
PCF
PCH
PCM
PCPM
PDSN
PDU
PER
Physical
Channel
Pilot
Channel
PLD
PN
PSA
PSTN
QCELP
QOF
QOF
QoS
RAN
RC
RCC
RDCH
Reverse
Traffic
Channel
Description
Mobile Station
Mobile Switching Center
Mean Time between Failure
Mean Time to Repair
Network Directed System Selection
Next Generation Networks
Network Management System
Operation, Administration, and Maintenance
Orthogonal channel Noise Simulator
Operating System
Orthogonal Transmit Diversity
Other User Noise Source
Priority Access Channel Assignment
A code channel in a Forward CDMA Channel used for transmission of control
information and pages from a base station to a mobile station
Printed Board Assembly
Private Branch Exchange
Printed Circuit Board
Packet Control Function in IP-BSC
Paging Channel
Pulse Code Modulation
Primary BSC Call Processing Board
Packet Data Serving Node
Protocol Data Unit. An atomic set of data, header information, and control
information that are provided by a service user to a service provider.
Packet Error Rate
Radio transmission link
An un-modulated, direct-sequence spread spectrum signal transmitted by a
CDMA base station or mobile station. A pilot channel provides a phase
reference for coherent demodulation and may provide a means for signal
strength comparisons between base stations for determining when to handoff.
Program Loaded Data
Pseudo Noise
Power Supply Assembly
Public Switched Telephone Network
Qualcomm Code Excited Linear Prediction
Quasi-Orthogonal Function
Quasi Orthogonal Function
Quality of Service
Radio Access network
Radio Configuration
Radio interface Call Control
Reverse Dedicated Signaling Logical Channel
A traffic channel on which data and signaling are transmitted from a mobile
station to a base station. The Reverse Traffic Channel is composed of up to one
Reverse Dedicated Control Channel, up to one Reverse Fundamental Channel,
zero to two Reverse Supplemental Channels, and zero to seven Reverse
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 46 of 56
6/14/2006
AW 96 Series System Installation Manual
Acronym
RF
RLC
RLP
RLSD
RP
RPSU
RRCU
RRM
RRP
RRQ
RSCH
RSSI
RTP
RU
RUpd
SAP
SAR
SCCH
SCCP
SCH
SDU
SEU
SIGTRAN
Slotted Mode
SMS
SMV
SRBP
SRU
SS
STS
Sync
Channel
TCC
TCE
TCM
TCP
TOD
TP
TPTL
UART
UDP
Description
Supplemental Code Channels.
Radio Frequency
Release Complete
Radio Link Protocol. Connection-oriented, negative-acknowledgement-based
data delivery protocol.
Released
Radio Network – PDSN
Remote RF Power Supply Unit
Remote RF Control Unit
Radio Resource Management Block
Registration Reply Message
Registration Request Message
Reverse Common Signaling Logical Channel
Received Signal Strength Indication
Real-Time Transport Protocol
Remote RF Unit
Registration Update Message
Service Access Point
Conceptual point at the interface between two adjacent layers where services
are provided to the upper layer and data and protocol information is exchanged
between layers.
Segmentation and Reassembly
Supplemental Code Channel
Signaling Connection Control Protocol
Supplemental Channel
Selection and Distribution Unit
Sector Expansion Unit
Signaling Transport processing module in IP-BSC
An operation mode of the mobile station in which the mobile station monitors
only selected slots on the Paging Channel
Short Message Service
Selectable Mode VOCODER
Signaling Radio Burst Protocol. An entity that provides connectionless protocol
for Signaling messages.
Sector Reduction Unit
Soft Switch
Space Time Spreading
A code channel in the Forward CDMA Channel which transports the
synchronization message to the mobile station
Traffic Channel Control Block
Traffic Channel Element
Traffic Control Module in BTS
Transmission Control Protocol
Time of Day
Traffic processing and Path Control module in IP-BSC
Transmit Power Tracking Loop
Universal Asynchronous Receiver/Transmitter
User Datagram Protocol
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 47 of 56
6/14/2006
AW 96 Series System Installation Manual
Acronym
VSWR
XCV
XCVR
Description
Voltage Standing Wave Ratio
Base Station Transceiver Control Block
Transceiver Board
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 48 of 56
6/14/2006
AW2100U System Installation Manual
10 Appendix B - Site preparation checklist
AW-Series IP-RAN Site Preparation Check List for:
Site
Prep
Date
Com
Guide
Complete plete
Section
ITEM # Description
Customer Contact & Equipment location
a. Main Contact Customer
1.1.1
b. Other Customer Contacts
1.1.2
1. Power contact
1.1.2
2. Communications Facilities Contact
1.1.2
3. LAN Facilities Contact
1.1.2
4. MSC Security Contact
1.1.2
App. C
AirWalk Series IP-RAN Site Requirements
2.1
a. Space requirements
2.1.1
b. AirWalk Series IP-RAN placement Diagram
2.1.2
c. Installation Location for AirWalk Series IP-RAN Equipment
Complete Site Drawings Appendix B
Information
c. Complete Customer Questions Appendix C
{Customer Name}
2.1.2.1
App. B
__________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 49 of 56
6/14/2006
AW2100U System Installation Manual
ITEM # Description
Power requirements
Site
Prep
Date
Com
Guide
Complete plete
Section
Information
2.1.3
a. Location
b. Voltage
c. Amps
d. Connector
Security
2.1.3
a. MSC Equipment Room security
b. MSC Equipment room access
Communications Facilities
2.1.3
a. Number of T1 circuits
Connector
Location
LAN Facilities
2.1.3
a. Location
b. Connector
c. Carrier Network IP Address
d. AirWalk Series IP-RAN Component IP Addresses
Other Information
__________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 50 of 56
6/14/2006
AW2100U System Installation Manual
ITEM # Description
Site
Prep
Date
Com
Guide
Complete plete
Section
Information
a. Heat dissipation
b. Environmental specifications
2.1.4
c. Ambient temperature and humidity
2.1.4.2
d. Dust density
2.1.4.4
e. Altitude
2.1.4.5
f. Air conditioning
2.1.4.6
g. Fire protection
__________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 51 of 56
6/14/2006
AW2100U System Installation Manual
11
Appendix C - Installation Checklist
AW-Series IP-RAN Site Installation Check List for:
Address
{Customer Name}
Installer Name (s)
Customer Contact (s)
{AW-SERIES IP-RAN Installation Address}
ITEM
10
11
12
13
14
15
16
Install
Date
Manual
Complete
Section
Description
Verify Customer Contact & Equipment location
Contact Customer
Locate AW-SERIES IP-RAN Equipment
Locate and verify Floor Space
Uncrate and arrange for packing material disposal
Verify location of all distribution points (main and intermediate)
Power Check
Power Location
Verify Connector
Voltage
Amps
LAN Facilities check
Location
Verify IP Address
Verify Connector
Ping IP Address
Time
Customer
Installer
Contact
Initials
Initials
9.1.1
9.1.1.1
9.1.1.2
9.1.1.3
9.1.2
9.1.3
9.1.3.1
9.1.3.1.1
9.1.3.1.2
9.1.3.1.3
9.1.3.1.4
9.1.3.1.5
9.1.5.1.5
9.1.3.1.5
9.1.3.1.5
9.1.3.1.5
____________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 52 of 56
6/14/2006
AW2100U System Installation Manual
ITEM
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Install
Date
Manual
Complete
Section
Description
Time
Customer
Installer
Contact
Initials
Initials
Prepare IP addressable device diagram
9.1.3.1.5
Post IP diagram at: i) site; ii) customer; iii) Airwalk Customer Service
9.1.3.1.5
Install AW-SERIES IP-RAN Cabinet
9.2.1
Move AW-SERIES IP-RAN to location
9.2.1
Secure AW-SERIES IP-RAN in designated location
9.2.1
Verify all internal System connections
9.2.2
External System Connections
9.2.3
MAKE SURE ALL SYSTEM POWER SUPPLIES ARE TURNED OFF BEFORE PROCEEDING! ! !
Connect Power to Cabinet
9.2.4
Connect -48VDC to DC distribution panel (If applicable)
9.2.4
Connect 120-240 VAC to AC distribution panel (If applicable)
9.2.4
Connect Communications Facilities
9.2.5
Connect LAN Facilities to BSC
9.2.5
Connect LAN Facilities to BTS
9.2.5
Power-up procedure
9.2.6
Power-up Main cabinet/rack power, check LEDs
9.2.6.1
Complete any configuration options
9.2.6.2
System Certification Tests
9.3.2
Test Case #1 - Image/PLD loading
9.3.2.1
Test Case #2 – System Check
9.3.2.2
Test Case #3 – Tx check
9.3.2.3
Test Case #4 – Output power
9.3.2.4
Test Case #5 – GPS Check
9.3.2.5
Test Case #6 – BTS Alarm Check
9.3.2.6
Test Case #7 – System Reset
9.3.2.7
Test Case #8 – PN Check
9.3.2.8
____________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 53 of 56
6/14/2006
AW2100U System Installation Manual
ITEM
41
42
43
44
45
46
47
48
Install
Date
Manual
Complete
Section
Description
Test Case #9 – System Interface Check
Operation Tests
Test Case #1 – Voice Calls
Test Case #2 – Data Calls
Operator Specific Tests (If Required)
Site Clean Up & Documentation
Dispose of all packing material
Clean-up site
Update Installation Checklist
Get Customer Signature on Certification Document
Time
Customer
Installer
Contact
Initials
Initials
9.3.2.9
9.3.3
9.3.3.1
9.3.3.2
8.3.4
8.4.1
8.4.2
8.4.3
8.4.4
____________________________________________________________________________________________________________________
AirWalk Proprietary and Confidential
Page 54 of 56
6/14/2006
AW2100U System Installation Manual
12 Appendix D - Customer Certification Document
Date
Subject:
The subject AW-SERIES IP-RAN has been certified to be up and running today.
_______________________________________
AirWalk Communications, Inc. (Installation Team)
_______________________________________
Authorized Carrier Representative
__________________
Date
__________________
Date
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 55 of 56
6/14/2006
AW2100U System Installation Manual
This Page Marks End Of Document
___________________________________________________________________________
AirWalk Proprietary and Confidential
Page 56 of 56
6/14/2006

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 56
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:f2eeea65-af92-4236-951f-6d19d25cf620
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Create Date                     : 2006:06:14 12:03:18-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:06:14 12:03:18-05:00
Document ID                     : uuid:70b894bc-2325-432b-bb75-740299556dc8
Format                          : application/pdf
Creator                         : cosborn
Title                           : Microsoft Word - System Installation Manual-AW-10 PB-Mini_v1.1.doc
Author                          : cosborn
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R4HAW96R19AF7