AirWalk Communications AWFTRBU1 AW100 1900MHz 0.1mW User Manual
AirWalk Communications, Inc. AW100 1900MHz 0.1mW
User Manual
AW100 Series CDMA2000 1xRTT and 1xEV-DO IP Radio Access Network (IP-RAN) Installation and Maintenance Manual Version # 0.4 April, 2010 Prepared By AirWalk Communications, Inc. 1830 North Greenville Ave Richardson, TX, 75081 Phone: (972) 638-9400 Fax: (972) 638-9401 www.airwalkcom.com FOR USE BY TRAINED TECHNICIANS ONLY _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 1 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Revision History Version Date Person 0.1 0.2 0.3 0.4 07/24/2009 10/07/2009 12/2/12009 4/7/2010 R MacLennan N. Kafai N. Kafai A Cho Description Initial Draft Document for review Addition on Introduction Edited Specifications Edited Technical Specs Revision Numbering Key 0.x 1.0 1.x 2.0 Work in Progress Initial Document Approval Revisions Following Initial Document Approval Revisions Approval _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 2 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Table of Contents TABLE OF CONTENTS .................................................................................................................................. 3 INTRODUCTION ..................................................................................................................................... 5 1.1 1.2 1.3 1.4 1.5 1.6 PROPRIETARY INFORMATION NOTICE .................................................................................................. 5 PURPOSE OF DOCUMENT ...................................................................................................................... 5 SCOPE .................................................................................................................................................. 5 ORDER OF PRECEDENCE ....................................................................................................................... 5 TERMINOLOGY ..................................................................................................................................... 5 TELECOM STANDARDS ......................................................................................................................... 6 AW100 SAFETY AND COMPLIANCE INFORMATION .................................................................. 8 2.1 STATEMENT OF INTENT ........................................................................................................................ 8 2.2 SAFETY PRECAUTIONS ......................................................................................................................... 8 2.3 MAINTENANCE INFORMATION ............................................................................................................. 9 2.3.1 Cleaning ...................................................................................................................................... 9 2.3.2 Other Maintenance ...................................................................................................................... 9 2.4 LABELING ............................................................................................................................................ 9 2.4.1 Grounding ................................................................................................................................... 9 2.4.2 Label: Model Identification, FCC Identification, Power ............................................................ 9 2.5 REGULATORY COMPLIANCE INFORMATION ....................................................................................... 10 2.5.1 Radio Interference (FCC 15.19 Statement) ............................................................................... 10 2.5.2 Unauthorized Modifications (FCC 15.21 Statement) ................................................................ 10 2.5.3 Digital Device Interference (FCC 15.105 Statement) ............................................................... 10 2.5.4 RF Power Requirements ............................................................................................................ 10 AW100 SYSTEM INTRODUCTION .................................................................................................... 11 3.1 OVERVIEW ......................................................................................................................................... 11 3.2 AW100 NETWORK DIAGRAM ............................................................................................................ 13 3.3 HARDWARE CONFIGURATION ............................................................................................................ 15 3.3.1 Physical Description ................................................................................................................. 15 3.3.2 Typical Configurations .............................................................................................................. 15 3.3.3 Unit Photographs ...................................................................................................................... 16 3.4 SYSTEM CAPACITIES AND SPECIFICATIONS ........................................................................................ 17 3.4.1 AW-100 Technical Specifications .............................................................................................. 17 3.4.2 Radio Unit Technical Specification (Slim RU Series) ............................................................... 18 3.4.3 Power Supply and Environment Technical Specification .......................................................... 19 AW-100 COMPONENTS ....................................................................................................................... 20 4.1 AW-100 MAIN UNIT .......................................................................................................................... 20 4.2 RADIO UNIT (RU - SLIM RU SERIES) ................................................................................................. 21 4.3 OPTIONAL DC RPSU (DC POWER CONFIGURATIONS ONLY)............................................................. 22 4.4 COMPONENT LED CONFIGURATION .................................................................................................. 23 4.4.1 CCPB- (Call and Channel Processing Board) .......................................................................... 23 4.4.2 RU DC Power Distribution Unit (RPSU) [DC powered models only] ..................................... 24 4.4.3 Radio Units Front Panel Indicators (Slim RU Series) .............................................................. 25 AW-100 CABLING ................................................................................................................................. 26 5.1 5.2 5.3 POWER SUPPLY WIRING (AC / DC POWERED VERSIONS) .................................................................. 26 GROUNDING ....................................................................................................................................... 26 RF CABLING WITH RU ....................................................................................................................... 27 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 3 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 5.4 5.5 POWER SUPPLY WIRING (DC POWERED MODELS)............................................................................. 28 GPS ANTENNA CABLE WIRING.......................................................................................................... 30 FREQUENCY SETTING PROCEDURES .......................................................................................... 31 6.1 IBSM MANAGEMENT ......................................................................................................................... 31 6.2 LOCAL FA SETTING ........................................................................................................................... 31 6.2.1 MMI Connection ....................................................................................................................... 31 6.2.2 FA Change Procedure ............................................................................................................... 32 INSTALLATION PROCEDURES ........................................................................................................ 37 7.1 VERIFY CUSTOMER CONTACT AND EQUIPMENT LOCATION ............................................................... 37 7.1.1 Contact customer....................................................................................................................... 37 7.1.2 Locate and verify floor space .................................................................................................... 38 7.1.3 Uncrate and arrange for packing material disposal ................................................................. 38 7.1.4 Verify location of power distribution points .............................................................................. 38 7.1.5 Verify location of LAN facilities and connection points ............................................................ 39 7.1.6 Verify location of RF Antenna Systems, including GPS ............................................................ 39 7.1.7 Verify physical mounting racks are present and suitable .......................................................... 40 7.2 IP-RAN INSTALLATION PROCEDURES ............................................................................................... 41 7.2.1 IP-RAN System physical installation ......................................................................................... 41 7.2.2 Internal system cable connections ............................................................................................. 41 7.2.3 External system Connections..................................................................................................... 41 7.2.4 Power-up procedure .................................................................................................................. 42 7.2.5 Installation Completion ............................................................................................................. 43 7.3 INITIAL SYSTEM CONFIGURATION...................................................................................................... 43 7.3.1 Web Server Installation Tool Set-up.......................................................................................... 44 7.3.2 Web Server Connections ........................................................................................................... 44 7.3.3 IP-RAN Initial Configuration (default “booting mode”) .......................................................... 46 7.3.4 IP-RAN Re-Configuration (“running mode”) ........................................................................... 47 7.3.5 Additional Operation Tests ....................................................................................................... 48 7.4 SITE CLEANUP AND CUSTOMER SIGNOFF ........................................................................................... 48 7.5 RECOMMENDED INSTALLATION TOOLS AND SUPPLIES ...................................................................... 49 7.6 TROUBLESHOOTING PROCEDURES ..................................................................................................... 49 7.6.1 Before Calling for Assistance .................................................................................................... 49 7.6.2 When Calling for Assistance ..................................................................................................... 50 APPENDIX A - ACRONYMS................................................................................................................ 51 APPENDIX B - INSTALLATION CERTIFICATION DOCUMENT ............................................... 53 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 4 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 1 INTRODUCTION 1.1 Proprietary Information Notice THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC. 1.2 Purpose of Document The purpose of this document is to define the Installation, Maintenance and Safety Compliance of AirWalk Communications, Inc. unique CDMA IP Radio Access Network (IP- RAN), referred to herein as the AW100 product. The AirWalk AW100 series is available in two separate platforms: • AW100-1X which support CDMA - 1xRTT standard, which includes integrated Base Station Transceiver (BTS) and Base Station Controller (BSC) into a unique single compact enclosure. • AW100-DO which supports CDMA - 1xEVDO Rev. A standard which includes integrated Radio Node (RN) and Radio Network Controller (RNC) into a unique single compact enclosure. The target market and applications are in-building areas, corporations, corporate campuses, enterprises, university campuses, large industrial plants, stadiums, airports, shopping malls, blind spots, hot spots, rural areas, neighborhoods, and highways. 1.3 Scope The scope of this document covers the description, environmental specifications, equipment location, cabling, system installation and maintenance of the AirWalk AW-100. Specific models covered are identified in the section entitled “Model Information”. 1.4 Order of Precedence This System Installation Manual will take precedence over any previous AirWalk System Installation Manual or Document. 1.5 Terminology See the section entitled: Appendix A – Acronyms _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 5 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 1.6 Telecom Standards [1] 3GPP2 C.S0001 – 0006 Radio Interface Specifications for cdma2000 Spread Spectrum System [2] 3GPP2 X.S0013 – IMS/MMD Specifications [3] 3GPP2 A.S0013-C Interoperability Specification (IOS) for cdma2000 Access Network Interfaces – Part 3 Features [4] 3GPP2 A.S0014-C Interoperability Specification (IOS) for cdma2000 Access Network Interfaces – Part 4 (A1, A1p, A2 and A5 Interfaces) [5] 3GPP2 C.S0015 Short Message Service [6] RFC 3261 – Session Initiation Protocol [7] RFC 4566 – SDP: Session Description Protocol [8] RFC 3455 – Private Header (P-Header) Extensions to the Session Initiation Protocol for the 3rd-Generation Partnership Project (3GPP) [9] RFC 3325 – Private Extensions to the Session Initiation Protocol for Asserted Identity within Trusted Networks [10] RFC 3262 – Reliability of Provisional Responses in Session Initiation Protocol [11] RFC 3311 – The Session Initiation Protocol UPDATE Method [12] RFC 2976 – The SIP INFO Method [13] RFC 4028 – Session Timers in the Session Initiation Protocol [14] RFC 4306 – Internet Key Exchange (IKEv2) Protocol [15] TIA/EIA/IS-2000 Series Revision: C - Introduction to CDMA2000 Spread Spectrum Systems, 05/00/02 [16] Personal Station – Base Station Compatibility Requirements for 1.8 to 2.0 GHz CDMA PCS. [17] TIA/EIA-664 - Wireless Features Description, 12/00/00 [18] TIA/EIA Interim Standard 95 Revision A - Mobile Station –Base Station Compatibility Standard for Dual-Mode Wideband Spread Spectrum Cellular Systems, May 1995 [19] TIA/EIA-95-B - Mobile Station-Base Station Compatibility Standard for Dual-Mode Spread Spectrum Systems, October 31, 1998 [20] MSC to BS Interface Inter-Operability Specification (IOS) Sprint PCS IOS Document, v2.0a, December 4, 1997 [21] IMT-2000 Specification, (indoor wireless propagation) [22] RFC 3558 RTP Payload Format for Enhanced Variable Rate Codecs (EVRC) and Selectable Mode Vocoders (SMV), July 2003 [23] RFC 2833 RTP Payload for DTMF Digits, Telephony Tones and Telephony Signals, May 2000 [24] 3GPP2 A.S0013-C Interoperability Specification (IOS) for cdma2000 Access Network Interfaces – Part 1 Overview [25] 3GPP2 A.S0013-C Interoperability Specification (IOS) for cdma2000 Access Network Interfaces – Part 2 Transport [26] 3GPP2 A.S0013-C Interoperability Specification (IOS) for cdma2000 Access Network Interfaces – Part 7 (A10 and A11 Interfaces) [27] 3GPP2 C.S0002-D, Physical Layer Standard for cdma2000 Spread Spectrum Systems, March 2004 [28] 3GPP2 C.S0004-D, Signaling Link Access Control (LAC) Standard for cdma2000 Spread Spectrum Systems, Feb. 2004 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 6 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ [29] 3GPP2 C.20000.5-D, Upper Layer (Layer 3) Signaling Standard for cdma2000 Spread Spectrum Systems, March 2004 [30] IS-707-A-2, Data Service Options for Spread Spectrum Systems, March 2001 [31] TIA/EIA/IS-856-A, cdma2000 High Rate Packet Data Air Interface Specification, Mar 2004 [32] C.R1001-D, Administration of Parameter Value Assignments for cdma2000 Spread Spectrum Standards, Release B [33] RFC 1661, Point-to-Point Protocol, July 1994 [34] RFC 1662, PPP in HDLC-Like Framing, July 1994 [35] RFC 1701, Generic Routing Encapsulation (GRE) Protocol, Oct 1994 [36] RFC 1994, PPP Challenge Handshake Authentication Protocol (CHAP), August 1996 [37] 3GPP2 A.S0008-0 v3.0 (TIA-878-1 pub), “Interoperability Specification (IOS) for High Rate Packet Data (HRPD) Access Network Interfaces”, May 2003 [38] 3GPP2 A.S0007-A v2.0 (TIA-1878 pub), “Interoperability Specification (IOS) for High Rate Packet Data (HRPD) Access Network Interfaces – Rev A”, May 2003 [39] 3GPP2 C.S0024-A v1.0 (TIA-856-A), “cdma2000 High Rate Packet Data Air Interface Specification”, March 2004 [40] 3GPP2 C.S0032 v2.0, Recommended Minimum Performance Standards for cdma2000 High Rate Packet Data Access Networks, Jan. 2004 [41] 3GPP2 X.S0011-001-C v3.0, cdma2000 Wireless IP Network Standard, Oct. 2006 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 7 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 2 AW100 Safety and Compliance Information 2.1 Statement of Intent The AirWalk AW100 Series IP-RAN is intended for use in a CDMA cellular infrastructure radio access network. The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 2.2 Safety Precautions Power Sources Use only power sources that are within the specified limits as designated on the equipment labels. Use of power sources outside the specified limits is hazardous and may cause personal injury or property damage. Equipment Location Equipment should be located indoors or in a suitable protected environment such as an equipment enclosure. Use of unprotected equipment outdoors is hazardous and may cause personal injury or property damage. Grounding and Electrical Connections Electrical connections, including equipment grounding, should be made in accordance with the National Electric Code and any local regulations. Improper electrical connections are hazardous and may cause personal injury or property damage. Consult a licensed electrical installer if in doubt. DC powered units MUST be externally fused for proper protection. Hazardous Voltages Equipment may contain hazardous voltages. Only qualified service personnel should open the equipment for adjustments, repairs or replacements. Replacement Parts Damaged parts and protective devices such as fuses should only be replaced by components approved or recommended by AirWalk Communications. Replacement fuses must be of the same rating and type as the original for continued protection. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 8 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 2.3 Maintenance Information 2.3.1 Cleaning The AirWalk AW100 units are protected by a high performance paint which does not require normal maintenance. If paintwork is soiled, it can be cleaned using a damp cloth after AC power has been disconnected. Do not use liquids or spray cleaning substances on the unit, since property damage or personal injury may result. 2.3.2 Other Maintenance Any other required maintenance must be performed by suitable trained service personnel. Do not open covers or attempt to repair unit if not suitably trained. 2.4 Labeling 2.4.1 Grounding Proper grounding is recommended to ensure good RF performance in addition to personnel safety. Antenna systems should also be suitably grounded for good RF performance. Grounding connection points on the chassis are located on the rear of the unit and are identified by this symbol: 2.4.2 Label: Model Identification, FCC Identification, Power The following illustrates the location of the FCC label that will be applied to the AW100 unit to provide model identification, FCC identification and rated power supply information. Some units are not equipped with FCC identification and therefore operation of these units in the US is not permitted. PWR 12VDC RUIF BSIF BSIF 10M EVEN GPS ANT TRX RXA RXB FCC ID Label Location Bottom Side of Unit Figure 2-1 AW100 Main Unit (Bottom - Rear View) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 9 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 2.5 Regulatory Compliance Information The FCC regulatory compliance information provided in this section is applicable only to models equipped with an FCC Identification Number (FCC ID). IP-RAN Base Station Model : AW100xxxxxxx FCC ID : R4Hxxxxxxxx S/N : 50.0 mm XX0000X DC IN: 12 VDC / 8A AirWalk Communications., Inc Contact: +1-972-638-9400 Made In U.S.A. 76.0 mm Figure 2-2 AW-100 FCC Label (SAMPLE) 2.5.1 Radio Interference (FCC 15.19 Statement) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2.5.2 Unauthorized Modifications (FCC 15.21 Statement) Persons or parties responsible for operation of this equipment are cautioned that any changes or modifications not expressly approved by AirWalk Communications Incorporated could void the user’s authority to operate this equipment. 2.5.3 Digital Device Interference (FCC 15.105 Statement) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 2.5.4 RF Power Requirements The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 10 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3 AW100 System Introduction 3.1 Overview This document describes the AW100 IP-RAN products developed by AirWalk Communications Inc. The AirWalk AW100 Series is compact, standards compliant, optimal channel capacity, cost effective, and reliable cellular access point designed to provide improved mobile coverage and capacity enhancements for the CDMA mobile operators. The AW100 is offered in two different platforms: • AW100-1X • This product is designed specifically for CDMA2000 1xRTT networks. The principal elements of the AW100-1X product are integrated BTS, BSC, and PCF functionality with the capability to connect to the core network via: • • IOS 5.X for connectivity to CDMA soft switch networks IOS to SIP messages for connectivity to IMS networks The following is a list of general characteristics: • • • • • • • • • • • • • • • • • • • • Supports both CDMA 1xRTT voice and data calls Supports 32CE and /or 64 CE (Up to 28 or 56 users) Supports CDMA 1xRTT data service transmission up to 144 kbps One carrier/ omni configuration Supports soft handoff, and hard handoff Offered in 0.1 mW or 200 mW transmit power Available with 0.1 mW platform to connect to high power LPA High sensitivity internal GPS system connected with an external antenna Integrated BTS/BSC/PCF functionality Compatible with IOS5.x or native IOS-SIP adaptation IPSec tunnel support ( for IOS-SIP Adapter only) Supports Integrated Base Station Management (IBSM) Supports 1900 MHz, 800 MHz, 450 (A) MHz bands 19 inch rack or cabinet mounting options AC or optional DC power supply systems Ethernet backhaul connections, compatible with most routers and multiplexers Remote O&M support through IP network Easy repair by replacement of modular units Improved reliability, and QoS Provides an ‘All-IP’ solution _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 11 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ • AW100-DO • This product is designed specifically for CDMA2000 1xEV-DO Rev. A networks. The principal elements of the AW100-DO product are integrated RN, RNC, and PCF functionality with the capability to interface to the core data network via IP10/100 Base T Ethernet to PDSN and AAA systems The following is a list of general characteristics: • Supports high speed packet data, fixed/portable/fully mobile use - “Always-On” experience • • • • • • • • • • • • • • • • • • • • 3.1 Mbps peak download speed 1.8 Mbps peak upload speed Based on Qualcomm CSM 6800, and supports IS-856A standard Integrated RN and RNC in one compact physical platform Supports up to 192 Channel Elements (CE) – for all configurations Available in 1 carrier / omni configuration Available with low power and high power LPA configurations 19 inch rack or cabinet mounting options AC or optional DC power supply systems Supports 450(A) MHz, 800 MHz, 1.9 GHz bands Supports hard and soft handoffs Provides low latency – similar to 1xRTT Supports QoS priority Backward compatibility and interoperability with legacy DO systems Ethernet backhaul connections, compatible with most routers and multiplexers Powerful OAM&P system – IP-based connectivity Easy repair by replacement of modular units Easy overlay with 1xRTT networks Works seamlessly with existing IP-based network infrastructure 100% end-to-end IP network – all IP Solution _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 12 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3.2 AW100 Network Diagram The following diagram is typical network architecture for AW100-1X using IOS5.x standard interfacing to a CDMA softswitch network. PSTN Media Gateway / CDMA Softswitch HLR AirWalk AW100‐1X IP Backhaul ISP IP Intranet Internet PDSN AirWalk Integrated Base Station Manager (iBSM) HA/AAA The following diagram is typical network architecture for AW100-1X using IOS to SIP adapter protocol interfacing to an IMS network. GMSC Convergence Server Macro 1xRTT RAN CDMA Service Layer (Subset) VM MMS MPC SMSC HLR IMS Core AirWalk AW100‐1X Broadband IP Sec PSTN IP Intranet Security Gateway (optional) PDSN HA/AAA AirWalk Integrated Base Station Manager (iBSM) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 13 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ The following diagram is typical network architecture for AW100-DO with connectivity to data core networks. AirWalk AW100‐DO IP Backhaul ISP IP Intranet Internet PDSN HA/AAA AirWalk Integrated Base Station Manager (iBSM) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 14 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3.3 Hardware Configuration The AW00 Series IP-RAN is a unique combination radio and controller in one physical platform that is differentiated from other systems. Other systems have separate radio and controller platforms which add to cost and complexity in order to support CDMA2000 networks. The main components are (depending on specific model): • AW100 (Main Unit) o CCPB - Call & Channel Processing Board In case of AW100-1X is referred to as CCPB-1X In case of AW100-DO is referred to as CCPB-DO • • Provides RN and RNC function FTRB - Femto Transceiver Board Provides BTS and BSC function Provides frequency up down function Offered in 1900 MHz, 800 MHz, 450 MHz frequency bands GTIB - GPS & Timing Interface Board Provides highly accurate position information PSU – Power Supply Unit • Sector RU - Remote RF Unit (Slim Series, for use with MacroCell applications) o HPAU - High Power Amplifier Unit • DC RPSU (DC powered configurations) o DC power distribution unit o Provided for optional DC powered RU system configurations only 3.3.1 Physical Description • Main Unit o Dimension (H x W x D): 1.75 x 12.25 x 9 (Inc), 4.45 x 31.12 x 22.86 (CM) o 19” EIA Rack x 1 Rack Unit o Weight: 4 Kg, [2 lbs] • Remote RF Unit [Slim RU Series] o Dimension (H x W x D): 3.5 x19 x 18 (Inc), 8.8 x 48.2 x 45.7 (CM) o 19” EIA Rack x 2 Rack Units o Weight: 13 kg [29 lbs] • DC RPSU [DC powered configurations] o Dimension (H x W x D):1.75 x 19 x 18 (Inc), 4.4 x 48.2 x 45.7 (CM) o 19” EIA Rack x 1 Rack Unit o Weight: 2 kg [4.4 lbs] 3.3.2 Typical Configurations The following shows typical component configurations for common applications. Macrocell Solution - Omni High Power Systems (20W) - AW100 Main Unit - 20W Slim Radio Unit (external RF power amplifier) - Optional DC RPSU for DC powered systems _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 15 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Minicell Solution - Omni Medium Power Systems (up to 4W) - AW-100 Main Unit - 4W Slim Radio Unit (external RF power amplifier) - Optional DC RPSU for DC powered systems Pico / Enterprise Solution - Omni Low Power Systems (up to 200mW) - AW100 Main Unit 3.3.3 Unit Photographs The following photographs (front views) show the rack mountable units for AW100 systems: Pico/ Enterprise Solution - One Carrier / Omni configuration with 200 mW transmit power Figure 3-2 AW100-1X Main Unit Mini / Macro Solution - One Carrier / Omni configuration with 4/20 W External RU Figure 3-3 AW100-DO with 20W Slim Radio Unit (RU- external RF power amplifier) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 16 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3.4 System Capacities and Specifications 3.4.1 AW-100 Technical Specifications AW100 Specifications 1xEV-DO Rev A 1xRTT Picocell: 200mW / 23dBm Transmit Power Microell: 4W / 36dB External RU Macrocell: 20W / 43dB External RU RADIO Air Interface CDMA2000, 1xEV-DO Rev. A CDMA2000, 1xRTT, IS-95 A/B Frequency Bands 450 MHz, 800MHz, 1900 MHz 450 MHz, 800MHz, 1900 MHz Up to 60 Picocell:200 mW Macrocell: 0.1 mW with 20W/4W external RU Up to 28 Picocell: 200 mW Macrocell: 0.1 mW with 20W/4W external RU Channel Elements 192 CEs per enclosure 32/64 CE per enclosure Configuration 1 carrier / 1 sector omni 1 carrier / 1 sector omni Soft/Hard Soft/Hard RN, RNC, PCF and O&M BTS, BSC, PCF and O&M IOS4.2 – 5.0 (CDMA Softswitch) 3GPP2/MMD/SIP ( IMS Network) Simultaneous Calls Transmit Power Handoff CONTROLLER Integrated Core Network Interface ------------------------- PDSN IP-10/100 Base T Ethernet – (A10, A11) IP-10/100 Base T Ethernet – (A10, A11) (AN) AAA+HA IP-10/100 Base T Ethernet – (A12) IP-10/100 Base T Ethernet – (A12) INTERFACES POWER AC 100 VAC ~240 VAC DC +12 VDC Consumption 60W Temperature Operating 0°C to 50°C (32°F to 122°F) Humidity ENVIRONMENTAL 5 to 95% non-condensing Cooling Dimensions HxWxD Forced air 1.75” x 12.25” x 9” 4.45 cm x 31.12 cm x 22.86 cm Rack Mount Installation HARDWARE Weight < 4 lbs; < 2 kg Cooling Forced air Type Indoor / outdoor with air conditioned enclosure FCC certified, UL Regulatory Mechanical Specification RF Input and Output Connector GPS Antenna Connector AC Power Connector RNC/RNC/RN Ethernet Connectors RU Control and ENV Connectors SMA Female (Input/Output) TNC Female IEC From/To RU Phantom powered RJ-45 Ethernet Interface RJ-45 Serial Interface Table 3-1 AW100 Mechanical Specifications _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 17 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3.4.2 Radio Unit Technical Specification (Slim RU Series) Tx 1930 ~ 1950 MHz 1945 ~ 1970 MHz 1965 ~ 1990 MHz 869 ~ 894 MHz A/B/H Sub Bands available 43dBm, 20 Watt 53 ± 1.0dB 1.5: 1 43 ± 1.0dB Frequency Output Power Gain In/Out VSWR Coupling Value Attenuation Rx Freq. Range Spurious Emission @43dBm(20W)_1FA (Band Class 0,2,3,5,7,9) Spurious Emission @43dBm(20W)_1FA (Band Class 1,4,6,8) N American PCS (A/D) N American PCS (B/D/E) N American PCS (C/E/F) 800 MHz Cellular Band 450 MHz Band (incl NMT) CDMA Output: Isolator Included 100dBc Fc±750KHz -32dBc Min Fc±1.98MHz -48dBc Min Fc±2.75MHz -18dBm Min Fc±885KHz -42dBc Min Fc±1.98MHz -52dBc Min Fc±2.75MHz -18dBm Min Max Hold Marker RBW, VBW=30KHZ, BW=1MHz Max Hold Marker RBW, VBW=30KHZ, BW=1MHz Over Power 45 + 0.7dBm Over VSWR Protection Alarm 3:1 30~43dBm Over Temp. Protection Alarm @ 90o ± 2 o Base Plate Temperature Rx Frequency Gain Gain Flatness In/Out VSWR Attenuation Noise Figure Tx Freq. Range 1850 ~ 1870 MHz 1865 ~ 1890 MHz 1885 ~ 1910 MHz 824 ~ 849 MHz A/B/H available 24 ± 1.0dB 1.0dB max 1.5: 1 100dBc min 2.2dB max N American PCS (A/D) N American PCS (B/D/E) N American PCS (C/E/F) 800 MHz Cellular Band 450 MHz Band (incl NMT) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 18 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Mechanical Specification RF Input and Output Connector AC Power Connector RU Control Connector Weight SMA Female (Input) N Female (Output) IEC RJ-45 Serial Interface 13 kg (28.55 lbs.) 482mm(W) x 457mm(D) x 88mm(H) 19”(H) x 18”(D) x 3.5”(H) Dimensions ( W x H x D ) Per RU 2 Rack Units Table 3-2 Radio Unit Specifications (Slim RU Series) 3.4.3 Power Supply and Environment Technical Specification AC Input Power Supply For AC Powered Models Input Voltage: Input Frequency: AC Power Connector: AC 100Volts ~ 250Volts 50Hz ~ 60Hz IEC Dissipated Power For AC Powered Models AW100 Main Unit: Radio Unit (Slim RU) Maximum AW100 IP-BS 60 Watt Max (Efficiency 75%) 400 Watt Max (Efficiency 85%) 460 Watt Max (Main Unit & 1x Radio Unit) Table 3-3 AC Power Supply Specifications DC Input Power Supply For DC Powered Models (DC RPSU) Input Voltage: Fuse Rating: DC Power Connector (DC RPSU) DC 12 Volts ~ 30 Volts (float charge compatible) 50A Bolted Bus Bar; 2 hole lugs; ¼” holes; ¾” spacing (Use Blackburn CTL2-2516 or equivalent connector lug) Dissipated Power For DC Powered Models AW-100 Main Unit: Radio Unit (Slim RU) Maximum AW-100 IP-BS 60 Watt Max 270 Watt Max 330 Watt Max (Main Unit & 1x Radio Unit) Table 3-4 DC Power Supply Specifications (DC RPSU) Environment Specification Operating Temperature Storage Temperature Relative Humidity Noise Airborne Particle -0o ~ +50 o C -30 o ~ +60 o 5% ~ 95% - Non-condensing Less than 60dBA, distance 1.5m 0 ~ 90 ㎍/㎥ Table 3-5 Environment Specifications _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 19 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4 AW-100 Components 4.1 AW-100 Main Unit Figure 4-1 AW-100 Main Unit Photo (Front View) AW-IOO MMI PWR WAN STS INT IxRTT RESET Main +27Vdc IN Figure 4-2 AW-100 – Line Diagram (Front View) Figure 4-3 AW-100 Main Unit Photo (Back View) PWR 12VDC RUIF BSIF 10M EVEN GPS ANT TRX RXA RXB Figure 4-4 AW-100 – Line Diagram (Back View) (AC Version) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 20 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4.2 Radio Unit (RU - Slim RU Series) The Slim RU series Radio Unit provides high power macrocell capabilities for the omni site configurations. The Radio Unit functions include a 4W or 20W power amplifier (measured at the antenna port), RF filtering for Tx and Rx paths, a duplexer function system, and a power supply. All components are packaged in a compact two rack unit package. Figure 4-5 Radio Unit (RU – Slim RU Series) - Photo (Front View) Figure 4-6 Radio Unit (RU – Slim RU Series) - Photo (Rear View - AC Version) Figure 4-7 Radio Unit (RU – Slim RU Series) - Photo (Rear View – DC Version) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 21 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4.3 Optional DC RPSU (DC Power Configurations Only) DC powered Radio Unit (RU) systems are equipped with a separate DC power distribution unit which provides a single connection point for DC power source. Connections are provided for the 12v DC AW100 unit and the 27v DC Radio Unit. Front panel circuit breakers and voltage/current measurements are provided. The RPSU is also equipped with an alarm interface to deliver RPSU alarms to the RU system. Figure 4-8 RPSU DC Distribution Unit - Photo (Front View) Figure 4-9 RPSU DC Distribution Unit – Line Diagram Figure 4-10 RPSU DC Distribution Unit – Photo (Rear View) Figure 4-11 RPSU DC Distribution Unit – Line Diagram (Rear View) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 22 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4.4 Component LED Configuration 4.4.1 CCPB- (Call and Channel Processing Board) LED status indicators are provided on the AW100 IP-RAN. LED functions are described in the following pictures and tables. AW-IOO MMI PWR WAN STS INT IxRTT RESET Main +27Vdc IN PWR WAN STS INT RESET Figure 4-12 LED Highlight Name Color On Off PWR Green Power on WAN Green Power off Disconnect network Green STS INT Orange Green/Orange Orange Green Brink Note Connect network Lock GPS ANT cable status is OFF UNLOCK PLL lock Even_sec Table 4-1 AW100 Indicator Codes _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 23 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4.4.2 RU DC Power Distribution Unit (RPSU) [DC powered models only] The RU RPSU (DC Power Distribution Unit) is equipped with a digital voltmeter and digital ammeter as shown in Figure 4-13. Figure 4-13 RPSU DC Power Measurement Indicators (Front View) The following values are displayed on the front panel. AW100-DC Out (V) : Internal RU control unit voltage (nominally 12-14V) RUDC Out (V) : Main system DC voltage (nominally 27-28V) Main DC In (A) : Overall system current consumption (5-50A, load dependent) Circuit breakers are also provided for system protection. A master circuit breaker controls power to the complete IP-RAN unit. Individual circuit breakers are provided for protection of the main unit and RU amplifier system. Only DC powered models are equipped with the RPSU DC power distribution module. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 24 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4.4.3 Radio Units Front Panel Indicators (Slim RU Series) The Radio Unit is equipped with indicators for power, communication activities and alarms. The location of the RU front panel indicators is shown in Figure 4-14 (each RU). PWR FLT MST SLV Figure 4-14 Radio Unit Front Panel Diagram A description of Radio Unit Front Panel indicator functions is shown in Table 4-2. LED Color On Flash Off Note PWR Green Normal N/A No Power FLT Orange Fault N/A Normal MST Green N/A Comm No Comm Communications with AW100 SLV Green N/A Comm No Comm Communications with other RU AFEU power on indicator RU Alarm(s) detected Table 4-2 Radio Unit Front Panel Indicator Codes _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 25 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 5 AW-100 Cabling 5.1 Power Supply Wiring (AC / DC Powered Versions) AC Power Supply The majority of the AW-100 systems will be powered via the AC/DC power supply. Connect the AW-100 main unit and if applicable the optional Radio Unit system to suitable AC power sources as shown in Figure 5-1. Use only the AC / DC power supply and AC cables provided by AirWalk to ensure continued safe operation. AC/DC PWR 12VDC RUIF BSIF 10M EVEN TX/RX_A ANT RX_B ANT I D Setting TX TP RF TX I N RX_A TP RF RX_A OUT G PS AN T MasterSlave1 Slave2 MasterSlave1 Slave2 RX_B TP RF RX_B OUT I D Setting TRX RXA RXB Test PSU ALM RF TX I N TX TP RF RX_A OUT RX_A TP RF RX_B OUT RX_B TP TX/RX_A ANT RX_B ANT Figure 5-1 Power Supply Wiring (shown with optional RU) 5.2 Grounding Grounding of the AW-100 system to the local site grounding system is essential for both safety and proper RF performance. The grounding of the IP-RAN system should be integrated with the overall site grounding plan as designed by the site planning engineer. A “halo” perimeter grounding system is recommended for sites equipped with external antennas that are subject to possible lightning strikes. A ground strap is provided with each AW-100 system and each RU system to allow bonding to a ground bus bar or to a common rack grounding point. Each ground wire is installed on the AW-100 main unit and on the RU amplifier system as shown in Figure 52. Customer to provide and install (crimp to existing lug) ground cable (AWG 10-12) between system and the common ground. Other ground cabling or bus bars used in site installation must be suited to the purpose and meet any applicable local electrical codes. Ground connections should be tested for continuity after installation. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 26 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Common Rack Ground TOP VIEW Ground Points PWR 12VDC RUIF BSIF RUIF BSIF I D Setting POWER INPUT AREA 10M EVEN MasterSlave1 Slave2 G PS AN T TRX RXA RXB Test PSU ALM TX/RX_A ANT RF TX I N TX TP RF RX_A OUT RX_A TP RF RX_B OUT RX_B TP RX_B ANT Customer provided and installed ground cables Figure 5-2 Ground Wiring (shown with optional RU) 5.3 RF Cabling with RU The AW-100 transmitter output and diversity receiver inputs are connected to the Radio Units, which contain the duplexer, LNA (Low Noise pre-Amplifier) and HPA (High Power Amplifier) functions. Connect using RF jumper cables as shown in Figure 5-3. Communication between the AW100 and the RU is accomplished with the Master / Slave LAN cable (KDR45AE). This cable is connected from the AW100 RUIF port to the Master port on the RU as shown in Figure 5.3. Use only the cables supplied with the RU system for interconnection to the AW-100. Cables are labeled for ease of installation. See Figure 5-4 for RF cable specification. AirWalk provided cables PWR 12VDC RUIF BSIF 10M EVEN POWER INPUT AREA GPS ANT TRX RXA RXB ID Setting Master Slave1 Slave2 Test PSU ALM RF TX IN TX TP TX/RX_ A ANT To Antenna RF RX_ A OUT RX_A TP RF RX_ B OUT RX_B TP RX_B ANT Figure 5-3 Radio Unit RF Cabling Diagram It is important to ensure transmit and receive connections are made correctly to prevent damage or field operational problems such as: Damage due to transmitting into a receiver port Crossed over diversity receive ports _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 27 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ SS405 Coaxial Cable Figure 5-4 AW-100 to RU RF Cable Specification Connect the external transmission lines from the diversity antenna systems to the RU Antenna connections as shown in Figure 5-3. External connectors are “N-Type”. Transmission line (or jumpers to transmission line) type and length will impact the overall link budget calculations for the cell site. Be sure to include these losses in the RF system design calculations for coverage. 5.4 Power Supply Wiring (DC Powered Models) Applications that dictate only DC systems are to be used will require a separate DC Distribution Unit (RPSU) which provides DC power distribution and over current protection for connected equipment. The RPSU also provides voltage and current measurement meters on the front panel. The RPSU will support the AW-100 and the optional RU. The RPSU must also be grounded in a similar manner as the other system components. Connect the AW-100 main unit power interconnect cable between the main unit and the RPSU Power Supply as shown in Figure 5-5. Use only the cable supplied with the RU system for this purpose. Tighten connector captivating screws to prevent accidental disconnection. PWR 12VDC RUIF BSIF 10M EVEN I D Setting ON OFF TX/RX_A ANT TX TP RX_A TP Master Slave1 RF TX I N +27VDC GND RX_B TP AW100-2 Power + 12Vdc A1 A2 A3 Slave2 TRX Test RXA RXB PSU ALM TX/RX_A ANT RF TX I N TX TP RF RX_A OUT RX_A TP RF RX_B OUT RX_B TP N/C RF RX_A OUT Master Slave1 RX_B ANT G PS ANT Slave2 I D Setting RF RX_B OUT AW100-1 Power +12Vdc A1: +12vDC A2: G N D A3: N /C RU3S Power RU2S Power RU1S Power +27Vd A1 A2 A3 RX_B ANT 27V( + ) Alarm GND( -) A1: +27vDC A2: G N D A3: N /C Main +27Vdc I N DC Cables (AirWalk provided ) Figure 5-5 AW-100 and RU to RPSU Power Connections [DC models] _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 28 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Connect the RPSU main power bus to the external DC power supply system using the two-hole bolted connections as shown in Figure 5-6. Power lugs and connection bolts are NOT supplied with the AirWalk system Figure 5-6 External DC Bus Power Connections [DC models] The following practices are recommended for DC bus connections: Use suitable lugs (Blackburn CTL2-2516 or equivalent lug recommended) Use suitable gauge cables (#2/#4 gauge flexible stranded recommended) Tighten bolts firmly to prevent movement or arcing Use heat shrink tubing, or equivalent, to cover and protect connections Power source should be independently fused at the origin point IMPORTANT – Do not turn on power source until installation is fully completed. IMPORTANT – Extra care is required when working with high current DC power systems to avoid personal injury. Protect all DC connections to avoid accidental short circuits. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 29 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 5.5 GPS Antenna Cable Wiring The AW-100 utilizes a 5.0V GPS system. GPS antennas can be ordered as optional equipment or supplied by customer. Connect the external GPS antenna RF cable to the “SMA” GPS antenna port on the AW-100 unit as shown in Figure 5-7. The GPS antenna must be located outdoors in a position to see the general sky. The GPS antenna must see at least four GPS satellites in the sky to receive enough time information for proper system operation. PWR 12VDC RUIF BSIF 10M EVEN GPS ANT TRX RXA RXB Figure 5-7 GPS Antenna Connection _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 30 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 6 Frequency Setting Procedures This section provided to meet regulatory requirements in certain jurisdictions which require local frequency setting procedures. Normally frequency settings should be made only in the iBSM system which will subsequently download them to the base station. Refer to the iBSM manuals for configuration and operating instructions. 6.1 iBSM Management The AW-100 series base stations are normally managed by the centrally located iBSM (Integrated Base Station Manager) system which communicates with the AW-100 over an IP connection. The iBSM downloads system software and configuration information which includes the physical FA (Frequency Assignment) for each base station. The base station tunes to the correct frequency as defined by the BSM configuration files. Refer to the iBSM operations manual for instructions on base station remote configuration. 6.2 Local FA Setting It may be required to set the AW-100 series base station physical FA locally for specialized test purposes or when the iBSM connection is unavailable (for example during early RN installations). This can be done using the local MMI (Man Machine Interface) port and a local PC. The configuration data downloaded from the iBSM will override local settings when iBSM connections are established. 6.2.1 MMI Connection Connect the serial port of the PC to the “RN MMI” port on the AW-100 front panel. Use only the Serial MMI cable provided by AirWalk and the following port settings: • 115200 baud • 8 bit • No Parity • 1 stop bit • No flow control Figure 6-1 Serial MMI Cable Connection _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 31 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 6.2.2 FA Change Procedure The AW-100 is consists of two different family of IP-RAN. AW100- 1xRTT The following menu driven commands permit local changes of the FA. Step 1 At the prompt enter the following: > pn3383 // this will take you to the menu screen similar to below: ================= PN 3383 ==================== 1. Tx Test 2. Rx Test 3. ParameterSetup 4. Rf Gain Display 5. xcvrSetup 6. ampSetup 7. Normal Gain Display 8. MakeTestCall 9. callClear 10. Overhead Calibration Control 11. Test Phone Setup (678 4711709) 12. Handoff Test 13. Set RF Test 14. System Calibration 15. Display BTS Status 0. Exit -------------------------------------------------Select Number ===> Step 2 Enter the following: Select number => 5 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 32 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ // this will take you to the below menu screen. ================= XCVR SETUP ==================== 1. SET CHAN 2. SET TX ON 3. SET TX OFF -------------------------------------------------4. Show Channel 5. SHOW XCVR MODEL ID 6. SHOW XCVR STATUS 7. SHOW XCVR LEVEL 8. Show RSSI1 9. Show RSSI2 10. Show TSSI 11. Show RSSI1PWR 12. Show RSSI2PWR 13. Show TSSIPWR 14. Show XCVR Temperature 15. Show XCVR Version 16. Show XCVR Reset Reason 17. Show XCVR Cable Status 18. Show XCVR PLL LOCK 19. Show XCVR Power Status 0. Exit -------------------------------------------------Select Input Number =====> Step 3 Enter the following: Select Input Number => 1 // choosing 1 will take you to the below menu. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 33 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ ALPHA : xcvrChangeCh Num [001 ~ 1500] [1175] [/0:Exit]==> Step 4 From the above menu, type the new channel desired (CDMA channels from 1 to 1500) and 0 to exit. Only standard CDMA channel numbers within the designated band capability of the radio is accepted by the base station. PS) Step 5 CDMA Channel to CDMA Frequency Assignment Correspondence Transmit Frequency Band (MHz) Band CDMA Channel Number (Base Station) 1 ≤ N ≤ 799 880.02 ~ 893.37 (800MHz) 991 ≤ N ≤ 1023 869.04 ~ 870.00 0 ≤ N ≤ 1199 1930.00 ~ 1989.95 (1900MHz) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 34 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ AW100- 1xEV-DO The following menu driven commands permit local changes of the FA. Step 1 At the prompt enter the following: > mpt32a // this will take you to the menu screen similar to below: ================================================ 1. Transmitter Test 2. Receiver Test 3. Parameter Setup 4. RF Gain Display 5. XCVR Setup 6. Turn Debug Messages On 7. Turn Debug Messages Off 0. Exit ================================================ Select Number ===> Step 2 Enter the following Select Number ==> 5 // this will take you to the below menu screen. ===================== XCVR SETUP ==================== 1. Set Channel 2. Set TX On 3. Set TX Off 4. Set Att. Gain 5. Set Reset Reason ----------------------------------------------------6. Show Channel 7. Show XCVR Model ID 8. Show Att. Gain 9. Show RSSI1 _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 35 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 10. Show RSSI2 11. Show TSSI 12. Show RSSI1PWR 13. Show RSSI2PWR 14. Show TSSIPWR 15. Show XCVR Temperature 16. Show XCVR Reset Reason 17. Show XCVR Cable Status 18. Show XCVR PLL LOCK 19. Show XCVR Power Status 20. Show TX Status 0. Exit ===================================================== Step 3 Enter the following: Select Input Number => 1 // choosing 1 will take you to the below menu. ALPHA : xcvrChangeCh Num [001 ~ 1500] [1175] [/0:Exit]==> Step 4 From the above menu, type the new channel desired (CDMA channels from 1 to 1500) and 0 to exit. Only standard CDMA channel numbers within the designated band capability of the radio is accepted by the base station. PS) Step 5 CDMA Channel to CDMA Frequency Assignment Correspondence Transmit Frequency Band (MHz) Band CDMA Channel Number (Base Station) 1 ≤ N ≤ 799 880.02 ~ 893.37 (800MHz) 991 ≤ N ≤ 1023 869.04 ~ 870.00 0 ≤ N ≤ 1199 1930.00 ~ 1989.95 (1900MHz) _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 36 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 7 Installation Procedures This Section gives instructions for installing the AW100 Series IP-RAN and for connecting it to the wireless infrastructure. Always refer to the Cell Site Installation documents provided by the Project Engineer for the specific project. These instructions will include site specific installation requirements in addition to generic installation practices. Site specific installation instructions could also include special arrangements for power supplies, cabling, backhaul equipment connections and other specific requirements. Prior to installation, it is necessary to assign IP addresses and a permanent base station ID for each IP-RAN system installed. The IP address of the managing iBSM system is also required. This essential information is needed for site configuration prior to leaving the site. Once the IP-RAN ID, IP addresses and managing iBSM IP address are installed in the AW-100 Series IP-RAN base station, the base station can then establish a link to the iBSM and download the site specific configuration information in addition to any updated software loads. It is recommended that the central managing iBSM system be installed and each base station configuration exists in the iBSM prior to installation of the site. If this preparation is performed, then each installed base station will obtain a correct configuration immediately after installation and proper operation can be verified by the installer before leaving the site. If the managing iBSM is not present prior to installation, then the IP-RAN can be installed and will continuously attempt communication with the iBSM until found, and a configuration downloaded. This allows base stations to be installed prior to the installation of a central managing iBSM system installation if the project schedule requires early installation of the base stations. 7.1 Verify Customer Contact and Equipment location 7.1.1 Contact customer1 1) Verify customer and installer contact names for the installation. Contacts names should be provided for all persons or groups involve in site preparation or planning. 2) Verify a site specific installation plan is available and includes details on: a) Power connections b) Backhaul and LAN connections c) RF antenna system connections If not verifiable, have main customer contact provided names and method of contacting. 3) Ensure Installation team (if more than one person on team). NOTE: Make sure all changes are sent to the Installation Coordinator immediately. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 37 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 4) Determine when contacts are available for help (e.g.; Time of day, day of week.) for customer, installation teams and persons involved in the site planning. 5) Obtain any site access or security requirements (e.g.: ID Badges, Card-keys, Keys, Access codes) required to access installation site. 6) Locate the AirWalk IP-RAN equipment and any required support equipment. Arrange transportation of equipment to the site, if required. 7) Check for any visible shipment damage to the equipment prior to transportation or installation. If any damage is observed, then notify the carrier or responsible party to resolve any insurance inspection issues prior to handling or opening the packages. 7.1.2 Locate and verify floor space 1) Determine where the IP-RAN equipment is to be installed. Obtain and review site documentation including diagrams, floor plans and connection requirements before visiting the site. 2) Visit the site and verify that there is enough space to safely install the AirWalk units (refer to Site Preparation Checklist in Appendix B). 7.1.3 Uncrate and arrange for packing material disposal2 1) Carefully unpack the AW-100 and related components from packing material. 2) Check for any shipment damage.3 3) Be certain that all components match system order.4 4) Make arrangements for the disposal of all packing material discarded during installation. Some crating materials may require return to the manufacturer or warehouse for reuse and therefore suitable arrangements must be made. 7.1.4 Verify location of power distribution points 1) Locate the customer or site provided power connection points and verify adequacy. 2) AC powered models require a designated 120 VAC minimum 15A or 240 VAC minimum 7A outlet. No other equipment or receptacles should be connected to this outlet, other than low power accessories needed to support the IP-RAN operation such as an Ethernet switch. Use only the 6’ power cord supplied with the IP-RAN unit. NOTE: If any visible damage, contact the Installation Coordinator immediately. NOTE: Note any damage on the receivables receipt, and Installation Checklist. Contact the Installation Coordinator immediately. NOTE: If components do not match the system order, contact the Coordinator immediately. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 38 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3) +12 VDC Models require a rectified and filtered nominal 24V DC power source. Voltage can range from 22 VDC to 28 VDC to allow use with a float charged battery system. A designated 50A source with independent over current protection is required for each IP-RAN unit (fused or circuit breaker). No other equipment should be connected to the designated circuit breaker. 4) DC powered models require suitable cables with connector lugs to be supplied by the installer for connection to the DC power source. A #4 or a #2 AWG gauge fine stranded cable is recommended. Other gauges may be required depending on the calculated voltage drop. The recommended bolted bus bar connection is a Blackburn p/n CLT2-2516 or equivalent. Use the bolts supplied with the IP-RAN to connect to the bus bar. 5) Proper ground connections are essential for both safety and for proper RF performance. Racks must be equipped with either a grounded bus bar running the height of the rack, or a common bonding point with a dedicated ground cable connected to a common cell site ground system. Installation requires that both the IPRAN main unit and the RU amplifier system be connected to a common site ground using ground straps provided with the system. The site ground system must be independently tested and verified for low resistance to ground. 7.1.5 Verify location of LAN facilities and connection points 1) Locate the customer provided LAN connection points. This could be a dedicated Ethernet switch, or a set of Ethernet connection points on an IP transport system terminal. 2) The IP-RAN system requires one IP address for proper operation. RNC(BSC) and RN(BTS) are working by one. 3) All Ethernet connection should be made using RJ-45 connectors and Category 5 or 6 Ethernet cables capable of supporting 10/100BaseT operation. 4) The static IP Address setting for the IP-RAN will be done after power up using the web server tool (ref BSM Operations Manual). A site connection and IP addressing diagram should be prepared for each site and posted at the site after installation. 5) It is strongly recommended that a copy of local site IP routing and addressing diagrams be sent to AirWalk at the following address to support any remote diagnostics needed. Mail to: AirWalk Customer Service Centre 1830 North Greenville Ave., Richardson, Texas 75081 E-mail to: techsupport@airwalkcom.com 7.1.6 Verify location of RF Antenna Systems, including GPS 1) Locate the site antenna systems, transmission lines and interconnection jumpers. Follow the site interconnection diagrams provided by the RF Systems Engineer. It is essential both for proper system operation and for regulatory or licensing requirements that the antennas are connected to the correct sectors using the correct jumper cables. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 39 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 2) Any discrepancies or problems must be clarified and changes approved by the designated RF Systems Engineer prior to powering up any base station. 3) Locate the GPS antenna cables and verify the cable is equipped with a TNC connector for connection to the IP-RAN base station. Base station operation is still possible without a GPS connection; however, it will not be possible to implement soft handoff and related features. In cases where GPS is not provided, the base station will obtain local time from the BSM time server to ensure mobile handset display is correct. 7.1.7 Verify physical mounting racks are present and suitable 1) Rack mounted IP-RAN systems must be mounted in a suitable 19” EAI standard rack system that can support the weight of the IP-RAN and also provide adequate rear support for the power supply. Mounting height requirements are as follows: a) Main Unit 1 RU (Rack Units) [1 RU = 1.75” (44mm)] b) RU System 2 RU (Rack Units) [Omni RU System] c) DC RPSU 1 RU [DC models only] 2) The normal unit stacking lineup is (from bottom to top): RPSU; RU; Main Unit. Do not change this lineup since all the factory supplied cables are sized for this stack model. 3) It is MANDATORY that suitable rear support be provided at the bottom of the IP-RAN stack. a) In the case of 4 post racks, provide rear support using either a rear cross bar support, a shelf, or mounting brackets for the rear of the chassis. b) In the case of 2 post racks, provide a suitable heavy duty shelf capable of holding at least 100 lbs (45 kg). Other options include using a centre balanced shelf or installing a 4 post conversion kit with a support shelf. 4) Rack mounting screws are to be supplied by the installer as required. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 40 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 7.2 IP-RAN Installation Procedures 7.2.1 IP-RAN System physical installation 1) First, install any support shelves or brackets required to provide rear support. 2) Locate the correct holes and install the heaviest rack unit first, which will normally be the RU system. Installation normally requires at least two people to lift and locate the unit due to the heavy weight. Secure the RU system to the rack using appropriate rack mounting screws. Install a screw for each RU rack mounting hole to ensure enough physical support is provided. The RU is heavy; At least two people are required to lift and position the RU. 3) Install the RPSU (DC models only) below the RU system. Ensure the RPSU engages with the rear weight support mechanism (shelf or brackets). Secure the RPSU using suitable rack mounting screws. 4) Install the IP-RAN main unit above the RU system. Secure the IP-RAN main unit using suitable rack mounting screws. 7.2.2 Internal system cable connections 1) Install the RU control interface cable between the IP-RAN main unit and RU.. 2) Install the optional IPC jumper cable on the IP-RAN front panel. 3) DC Models Only :Install the alarm interface cable between the RPSU and the RU 4) DC Models Only: Install the DC power cable between the RPSU and the RU amplifier chassis. 5) DC Models Only: Install the DC power cable between the RPSU and the IP-RAN main unit. 6) Install the RF cables between the IP-RAN main unit and the RU system as illustrated in this manual. Verify all RF cable connections are correct before proceeding. Use only cables provided with the IP-RAN system to ensure proper operation. 7.2.3 External system Connections5 1) Establish external grounding points and install ground strap connections from the IPRAN main unit and the RU amplifier system to the common site ground points (refer to Section 5.2 for grounding details). Rack should be equipped with ground bus bars or bonding points that are cabling to a common cell site ground system. 2) Connect the external Ethernet backhaul connections. Use category 5 or category 6 cable that is certified for use in 10/100 Ethernet systems. WARNING: Make sure all system power supplies are turned off. All breakers / fuses are pulled on all main and intermediate panels. Then proceed with the installation. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 41 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 3) Connect the external GPS antenna to the IP-RAN GPS antenna input. Use a suitable RF cable (RG-58 or equivalent) equipped with a TNC connector. 4) Connect the external RF antenna systems. Follow site specific cable installation drawings prepared by the RF system/planning engineer for cable type and routing. The IP-RAN unit is equipped with N-type RF connectors. Ensure the individual sector antenna systems are connected to the correct IP-RAN sector antenna connections. Incorrect sector connections may cause operational or coverage problems. 5) AC Models Only: Connect the AC line cords for the IP-RAN a dedicated AC power source. Only use the cables provided with the system for continued safe operation. 6) DC Models Only: Locate and verify the polarity of the DC power source cables. Slip a 4” length of heat shrink tubing over each DC cable. Connect the cable lugs to the RPSU DC power bus bars using the supplied connector lug bolts. Tighten the bolts firmly to ensure a solid electrical connection. The use of electrical contact grease is acceptable if desired. Slide the heat shrink tubing over the bus bar connection and use a heat gun to secure the connection. Short circuits in high current DC power systems can be dangerous. All exposed DC connections must be protected to prevent accidental short circuits. 7.2.4 Power-up procedure Verify all connections are correct prior to powering up base station. 1) AC Models Only a. Switch on the AC power source. b. Switch on the IP-RAN main unit power switch located on the rear panel power entry point. The switch is located adjacent to the DC PWR connection. 2) DC Models Only a. Switch on or engage the circuit breakers at the +12 VDC power source. b. Switch on the RPSU main circuit breaker located on the RPSU front panel. c. Use the RPSU voltmeter to verify the presence of +24/27 VDC power. d. Switch on the RPSU RU circuit breaker located on the RPSU front panel. Note the increase in current consumption on the RPSU current meter. e. Switch on the IP-RAN main unit (AW-100) circuit breaker located on the RPSU front panel. Note the increase in current consumption on the RPSU current meter. 3) The IP-RAN unit will automatically initiate the startup procedure. 4) Verify communication between the IP-RAN main unit and the RU amplifier system by observing the communications indicators (led MST) on the RU front panel. The indicators should on to indicate communication is occurring. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 42 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 5) Verify the Ethernet backhaul links are communicating by observing the activity indicators on the external Ethernet switch. The activity indicators are typically found on the front panel or adjacent to the connection point on Ethernet switches. The indicators should be flashing intermittently to indicate the presence of IP packet activity. 7.2.5 Installation Completion Completion of the installation requires that all cables be suitably routed and bundled for a neat appearance. All cables should be tie wrapped as needed to ensure cables will not move or be stressed in normal system operation. External cables should be labeled in accordance with the site specific installation drawings prepared by the site planning engineer. All garbage and installation materials, including wire clippings and tie wrap ends, must be removed from the site prior to completing the installation. 7.3 Initial System Configuration Each IP-RAN system requires configuration of key site specific information prior to operation to allow the system to communicate and contact the controlling iBSM system. One this initial information is configured the system will automatically download software and configuration information from the iBSM. No additional on-site configuration is required after this initial configuration is completed. The following items must be configured in the base station after installation using the Web Server installation support tool: - IP-RAN IP Address: Locally valid static IP address (allows IP communications) - IP-RAN Identity: Unique identifier associated with a iBSM site configuration - Host iBSM IP Address of RNC: IP address of the controlling iBSM (allows initial contact) Additional capabilities are provided in the Web Server Installation Tool to identify sub-net masks and net gateways, and the ability to select optional boot modes. The required IP addresses and base station identity for a particular site are normally set up in advance by the network control center engineers prior to site deployment. Ensure this information has been provided prior to installation configuration. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 43 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 7.3.1 Web Server Installation Tool Set-up The Web Server Installation Tool is built into the IP-RAN base station. Connection to the tool requires only a PC equipped with an Ethernet capability and a common browser such as Explorer. Connection from the PC to the base station is made over the local Ethernet connection at the cell site, usually via the local on site Ethernet switch (Figure 7-1). Refer to the Web Server Installation Tool document for complete instructions on configuring the PC and browser to access the web server tool. Abbreviated instructions are provided in the remainder of this section for users previously familiar with the Web Server Tool. Figure 7-1 Initial Configuration Using Local Web Server 7.3.2 Web Server Connections There are some rules that should be followed when making the parameter changes. Some of the parameters have to be used with a valid IP address format such as “xxx.xxx.xxx.xxx”, where xxx is a digit between 0 to 255. The parameters that are important for the configuration of the AW100 are Primary IP Address, Subnet Mask, Host IP Address, and Gateway. In addition BSID, Base Station ID, should be composed of number between 0 to 4095. The value of 5000 is a special _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 44 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ BSID number that will be used for the manufacturing default number. This number should be changed before the operation can begin. Use these default addresses to access the AW100 functions for the first time using the PC browser. Enter these IP addresses in the browser address bar to gain access to the AW100 functions. Once a base station has been configured, the default addresses are not longer valid. To gain access locally to a base station that has already been configured (running), use either the new IP address (the primary address) or a secondary IP address in the AW100 IP-RAN system. It depends up the BSID value. This secondary IP address is an alternate means to access the system from within the unit’s LAN. The secondary IP Address takes the following format: 172.3X.YYY.ZZZ X = 0 for 1xEV-DO systems X= 1 for 1xRTT systems. Internally, the dotted fields are represented by eight bits per field for a total 32 bits per address. YYY and ZZZ fields are derived from the BSID by shifting the 12 bit BSID that range from 0 to 4095 as mentioned above. To calculate the BSID into YYY.ZZZ, shift the BSID by 4 bits then add the final bits. The final two bits are 01 for RN. For example BSID = 4095 can be calculated as follow: Decimal 4095 = hex FFF = bin 1111 1111 1111 Then shift 4 to left then add 01 = 1111 1111 1111 0001 Calculate it back to Hex = FF F1 YYY.ZZZ becomes FF.F1 and this will come up with secondary IP Address. For the above example of 1xRTT with BSID 4095 will have secondary IP Address as follow: 172.31.255.241 where X = 1 since it is 1xRTT product with YYY=FF=255 and ZZZ = F1 = 241. For the factory default setting with BSID=5000, following are secondary IP address: For 1xRTT system: 172.31.255.251 For EVDO system: 172.30.255.251 You must know either the base station id or the current IP address to access the web server function when the base station is running. The Web Server function is also equipped with a security log in to prevent unauthorized access from the local IP network. The following default log-in parameters are used: Login ID: air Password: airairair _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 45 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 7.3.3 IP-RAN Initial Configuration (default “booting mode”) Connection the PC to the RN using either the default factory IP address (new systems), or the primary address or secondary address (systems already configured). The window shown in Figure 7-2 will appear in the browser: Figure 7-2 Web Server Login Screen Enter the default login id and password to gain access to the configuration screen, which looks similar to Figure 7-3. Figure 7-3 IP-RAN Configuration Screen (default “booting mode”) Enter the required information and click on “Submit and Reboot” to set the parameters. The system will present the screen as shown in Figure 7-4. At this point, the system sets the configuration parameter and then proceeds to reboot. During reboot, the iBSM contacts and downloads the full site configuration. The reboot process can be interrupted by clicking on “RECONNECT”. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 46 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Figure 7-4 IP-RAN Configuration Screen (default “booting mode”) 7.3.4 IP-RAN Re-Configuration (“running mode”) An IP-RAN equipped with an existing configuration can again be accessed via the Web Server tool to change parameters. The connection to the IP-RAN must be made using either the current primary IP address or the secondary address which is based on the base station id. After connection, the login screen will appear as shown in Figure 7-5, indicating “running mode”. Figure 7-5 IP-RAN Re-Configuration Screen (“running mode”) Enter the default login id and password to access the configuration screen: _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 47 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Figure 7-6 IP-RAN Configuration Screen (“running mode”) Configuration changes are entered using this screen and accepted by the IP-RAN by clicking on the “Submit” button. However, the new changes will NOT become effective until the IP-RAN unit is rebooted. This can be done by clicking on the “Reboot” button. Once the IP-RAN unit reboots, it will use the new configuration information to contact the controlling iBSM system to download software images and/or configurations, as required or defined in the “bootoptions” setting. 7.3.5 Additional Operation Tests Additional operational tests may be required by the RF system/planning engineer, the network control centre engineers, or others in order to complete the base site installation. Such tests could include: Power output measurement (PPS or PN3383) Alarm function testing Test calls using mobile handsets or data terminals Drive testing and RF coverage/performance measurement Refer to the individual test checklists for completion and recording of any additional installation test activities. 7.4 Site Cleanup and Customer Signoff The following activities must be undertaken prior to completion of the site installation: Disposal of all packing and installation materials, including wire clippings Replace all equipment, covers, doors and other site equipment _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 48 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Completion of the installation checklist Final approval by the relevant customer authority 7.5 Recommended Installation Tools and Supplies 1) Hand Tools: a) Screwdriver set b) Pliers set c) Nut Driver set d) Cutter set e) Punch Down tool, or wire-wrap tool (site dependent) f) RJ-45 crimper tool 2) Test Equipment: a) Multi-meter and adapter kit b) PC equipped with Ethernet card and browser c) RF test set (power measurement, or optionally a CDMA test set) d) RF adapters 3) Supplies: a) RJ-45 connectors b) Cat 5 or 6 Cable c) Cable tie-wraps d) Rack mounting screws and related rack hardware 7.6 Troubleshooting Procedures The AW-100 Series CDMA IP-RAN system is designed to provide reliable and consistent high performance in all network environments. The installation procedure described in this manual for the IP-RAN is quite straightforward and simple to implement. Should problems develop during installation, this section is intended to help locate, identify, and correct these types of problems. Please follow the suggestions listed in the following sections prior to contacting the AirWalk Customer Support Center. If you are unsure of the procedures described in this section, contact the installation coordinator immediately for clarification. 7.6.1 Before Calling for Assistance 1) If difficulty is encountered with a specific component of the IP-RAN, refer back to the Installation Section for that component. 2) Check the cables and connectors to ensure that they have been properly connected and the cables/wires have not been crimped or impaired in some way during installation. _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 49 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ As a rule, 90% of component problems can be attributed to wiring and connector problems). a) Check cable b) Check connector c) Check for solid connection d) Check with site specific installation documentation 3) Make sure that all power cords are properly attached to each IP-RAN component. Be certain that all power cords are plugged into a functioning electrical outlet. Use the PWR LED’s and the voltage meters to verify each unit is receiving power. Check intermediate breakers or fuses. 4) If the problem is isolated to something other than the IP-RAN, contact the appropriate parties responsible for that system. 5) Verify whether or not the problem is corrected. If not, go to Step 6 below. If the problem is corrected, continue with installation. 6) If the problem continues after completing Step 4 above, contact the Installation Project Manager to determine the next course of action. If the problem persists after review, then contact the AirWalk Customer Support Center for assistance. 7.6.2 When Calling for Assistance Please be prepared to provide the following information. 1) A complete description of the problem, including the following points: a) The nature and duration of the problem b) Situations when the problem occurs c) The components involved in the problem d) Any particular application that, when used, appears to create the problem 2) A record of changes that have been made to the IP-RAN configuration prior to the occurrence of the problem. 3) Any changes to the system should all be noted. AirWalk Customer Service Center 1830 North Greenville Ave., Richardson, Texas 75081 E-mail to: techsupport@airwalkcom.com _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 50 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ 8 Appendix A - Acronyms Acronym 2G 3G AAA BHCA BSC BTS CA CALEA CDMA CPE CPU CSM5000 DC DHCP EVDO EVRC FA FCC FM FO GPS HLR HO HSS iBSM IF IMSI I-CSCF IOS IP IKE IMS IPSec LAN MG MN MS MSC MTBF PCF PSTN QCELP QOF QOF QoS RAN Description Second Generation in CDMA wireless network Third Generation in CDMA wireless network Authentication, Authorizing, and Accounting Busy Hour Call Attempts Base Station Controller Base station Transceiver Subsystem Call Agent – Softswitch Communications Assistance for Law Enforcement Act Code Division Multiple Access Customer Premise Equipment Central Processing Unit Cell Site Modulator 5000 (CDMA ASIC chip released by Qualcomm for cdma2000) Direct Current Dynamic Host Control Protocol Evolution Data Only Enhanced Variable Rate CODEC Frequency Assignment Federal Communications Commission Fault Management Frame Offset Global Positioning System Home Location Register Handoff Home Subscriber Server Integrated Base Station Management Intermediate Frequency International Mobile Subscriber Identity Interrogating Call Session Control Function Interoperability System Internet Protocol Internet Key Exchange IP Multimedia Subsystem IP Security Local Area Network Media Gateway Mobile Node Mobile Station Mobile Switching Center Mean Time between Failure Packet Control Function in BSC Public Switched Telephone Network Qualcomm Code Excited Linear Prediction Quasi-Orthogonal Function Quasi Orthogonal Function Quality of Service Radio Access network _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 51 of 54 AW100 Series System Installation Manual ____________________________________________________________________________ Acronym Description RC RN RF RNC RPSU RTP RU SDU SMS SS SIP Radio Configuration Radio Node Radio Frequency Radio Network Controller Remote RF Power Supply Unit Real-Time Transport Protocol Remote RF Unit Selection and Distribution Unit Short Message Service Soft Switch Session Initiation Protocol S-CSCF Serving Call Session Control Function _____________________________________________________________________________ AirWalk Proprietary and Confidential Page 52 of 54 AW-100 Series System Installation Manual __________________________________________________________________________ 9 Appendix B - Installation Certification Document Date: ______________________________________________________ Subject: _________________________________________________ The subject AW-100 Series IP-RAN has been installed and proper system operation has been verified on this date. _______________________________________ Installation Team Representative __________________ Date _______________________________________ Authorized Carrier Representative __________________ Date ____________________________________________________________________________ AirWalk Proprietary and Confidential Page 53 of 54 7/28/2010 AW-100 Series System Installation Manual __________________________________________________________________________ This Page Marks the End of this Document ____________________________________________________________________________ AirWalk Proprietary and Confidential Page 54 of 54 7/28/2010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2010:07:28 17:07:31-05:00 Create Date : 2010:07:28 17:07:31-05:00 Format : application/pdf Title : Microsoft Word - System Installation Manual AW-100 v0 4-andrew.doc Creator : rmaclennan Producer : Acrobat Distiller 8.2.3 (Windows) Document ID : uuid:195e4b4f-0681-4429-b7e2-17bf54f9e6a6 Instance ID : uuid:675f8943-d16b-4983-b523-4965081d26ed Page Count : 54 Author : rmaclennanEXIF Metadata provided by EXIF.tools