Airspan Networks MMAX3605 Base station radio User Manual MacroMAXe Installation Guide

Airspan Networks Inc Base station radio MacroMAXe Installation Guide

Contents

Users manual

Download: Airspan Networks MMAX3605 Base station radio User Manual MacroMAXe Installation Guide
Mirror Download [FCC.gov]Airspan Networks MMAX3605 Base station radio User Manual MacroMAXe Installation Guide
Document ID1250804
Application ID8cBBlR92VyttRMu7xgWfZw==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize89.08kB (1113514 bits)
Date Submitted2010-02-15 00:00:00
Date Available2010-04-21 00:00:00
Creation Date2010-03-09 14:40:30
Producing SoftwareAcrobat Distiller 8.2.0 (Windows)
Document Lastmod2010-03-09 14:43:22
Document TitleMacroMAXe Installation Guide
Document CreatorAcrobat PDFMaker 8.1 for Word
Document Author: Meyer Falik

UGD-D00181 Rev E
MacroMAXe 3x05
Installation Guide
Software Release 9.0
MacroMAXe Installation Guide
Copyright
© Copyright by Airspan Networks Inc., 2010. All rights reserved worldwide.
The information contained within this document is proprietary and is subject to all relevant copyright,
patent and other laws protecting intellectual property, as well as any specific agreements protecting
Airspan Networks Inc. rights in the aforesaid information. Neither this document nor the information
contained herein may be published, reproduced or disclosed to third parties, in whole or in part,
without the express, prior, written permission of Airspan Networks Inc. In addition, any use of this
document or the information contained herein for the purposes other than those for which it is
disclosed is strictly forbidden.
Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in
equipment design or specifications.
Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no
responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third parties
which may be effected in any way by the use of thereof.
Any representation(s) in this document concerning performance of Airspan Networks Inc. product(s)
are for informational purposes only and are not warranties of future performance, either expressed or
implied. Airspan Networks Inc. standard limited warranty, stated in its sales contract or order
confirmation form, is the only warranty offered by Airspan Networks Inc. in relation thereto.
This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability
assumed in relation thereto unless specifically undertaken in Airspan Networks Inc. sales contract or
order confirmation. Information contained herein is periodically updated and changes will be
incorporated into subsequent editions. If you have encountered an error, please notify Airspan
Networks Inc. All specifications are subject to change without prior notice.
Product performance figures quoted within this document are indicative and for information purposes
only.
Page 2
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Table of Contents
Copyright ................................................................................................................................................. 2
Table of Contents .................................................................................................................................... 3
Summary of Figures ................................................................................................................................ 6
Summary of Tables ................................................................................................................................. 8
Warnings and Cautions ........................................................................................................................... 9
Human Exposure to Radio Frequencies ............................................................................................. 9
Radio Interference ............................................................................................................................... 9
Avoiding Radio Interference ................................................................................................................ 9
Modifications ....................................................................................................................................... 9
General................................................................................................................................................ 9
Safety .................................................................................................................................................. 9
Warning Symbols .............................................................................................................................. 10
Service Information ........................................................................................................................... 10
UL Information ................................................................................................................................... 11
Lightning Protection .......................................................................................................................... 11
DECLARATION OF CONFORMITY ..................................................................................................... 13
FCC Notice ............................................................................................................................................ 15
Federal Communication Commission Notice .................................................................................... 15
GPS Compliance ............................................................................................................................... 15
Maximum Output TX Power .................................................................................................................. 16
Antenna Types .................................................................................................................................. 16
About this Guide ............................................................................................................................ 17
1.1
Purpose ................................................................................................................................. 17
1.2
Intended Audience ................................................................................................................ 17
1.3
Conventions .......................................................................................................................... 17
1.4
Referenced Documentation .................................................................................................. 17
1.5
Organization of this Guide..................................................................................................... 17
Introduction.................................................................................................................................... 19
Page 3
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
2.1
MacroMAXe........................................................................................................................... 19
2.2
MacroMAXe Frequency Ranges ........................................................................................... 19
2.2.1
Getting Started .............................................................................................................................. 22
3.1
Workflow of Installation ......................................................................................................... 22
3.2
MacroMAXe Installation Checklist......................................................................................... 23
Verify Prerequisites ....................................................................................................................... 24
4.1
Verify Safety Requirements .................................................................................................. 24
4.1.1
4.2
Verify Installation Requirements ........................................................................................... 25
Verify the Tools ............................................................................................................. 25
4.2.2
Verify the Parts and Kits ................................................................................................ 25
4.2.3
Verify Components ........................................................................................................ 29
Install MacroMAXe ........................................................................................................................ 32
5.1
Pole mount configuration ...................................................................................................... 32
5.2
Wall mount configuration....................................................................................................... 33
5.3
Install MacroMAXe Antennas ................................................................................................ 35
5.3.1
Install Dual Slant Antenna ............................................................................................. 36
5.3.2
Install Quad Slant Antenna ........................................................................................... 37
5.3.3
Antenna Mounting Clamps for Dual and Quad Slant Antennae ................................... 37
Optional Mounting Antenna on MacroMAXe......................................................................... 39
5.4.1
Variable Tilt Antenna ..................................................................................................... 39
5.5
GPS Antenna Assembly........................................................................................................ 40
5.6
Install Junction Box (Optional) .............................................................................................. 42
5.6.1
Junction Box Installation ............................................................................................... 42
Connect and Manage Cables........................................................................................................ 45
6.1
Warning of Hazardous Voltages ................................................................................... 24
4.2.1
5.4
Architecture ................................................................................................................... 19
Assemble Ethernet Connector .............................................................................................. 45
Set Power System ......................................................................................................................... 46
7.1
Page 4
Power Input - DC ................................................................................................................... 46
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Appendix A .................................................................................................................................... 47
8.1
Review Job Sheet ................................................................................................................. 47
Appendix C – Glossary of Terms .................................................................................................. 48
10
Appendix D – Installation Checklist ........................................................................................... 50
11
Appendix E ................................................................................................................................ 51
11.1
Revision History .................................................................................................................... 51
11.2
Contact Information ............................................................................................................... 51
Page 5
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Summary of Figures
Figure 1 - MacroMAXe Maximum Output TX Power ............................................................................ 16
Figure 2 – MacroMAXe Hardware Components ................................................................................... 20
Figure 3 – MacroMAXe Functional Components .................................................................................. 21
Figure 4 – Workflow of Installation ........................................................................................................ 22
Figure 5 – MacroMAXe Base Station Unit, Ethernet termination.......................................................... 29
Figure 6 – MacroMAXe Base Station Unit, RF ports ............................................................................ 30
Figure 7 – MacroMAXe Cable Assembly for GPS Antenna.................................................................. 30
Figure 8 - Lightning/Surge protector ..................................................................................................... 30
Figure 9 - Junction box with pole assembly .......................................................................................... 31
Figure 10 – Pole Mounted MacroMAXe Assembly ............................................................................... 32
Figure 11 – Pole Mounted MacroMAXe ................................................................................................ 33
Figure 12 – Wall Mounted MacroMAXe ................................................................................................ 34
Figure 13 – Wall Mounted MacroMAXe Wall Plate Details................................................................... 34
Figure 14 – MacroMAXe External Antenna Configuration .................................................................... 35
Figure 15 - MacroMAXe Antenna Dual Slant Mast Mount Configuration ............................................. 36
Figure 16 – MacroMAXe Antenna Quad Slant Mast Mount Configuration ........................................... 37
Figure 17 - Adjustable Mounting Kit, with Snaplock Stainless Steel Bands ......................................... 38
Figure 18 - Adjustable Mounting Kit, with ‘V’ Blocks ............................................................................. 39
Figure 19 - Variable tilt antenna ............................................................................................................ 40
Figure 20 - Antenna mounted on MacroMAXe ..................................................................................... 40
Figure 21 - GPS cable assembly prior to mounting .............................................................................. 41
Figure 22 - Attach GPS antenna to RG58 cable ................................................................................... 41
Figure 23 - GPS antenna assembled on bracket .................................................................................. 41
Figure 24 - Junction box with mounting brackets assembled ............................................................... 42
Figure 25 - mounting bracket (2 required) ............................................................................................ 42
Figure 26 - MacroMAXe assembly with optional junction box .............................................................. 44
Figure 27 – Ethernet connector cable termination ................................................................................ 45
Figure 28 – Ethernet environmental connector assembly .................................................................... 45
Page 6
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 29 – DC Power connector cable ................................................................................................ 46
Page 7
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Summary of Tables
Table 1 - Antenna Types - Technical .................................................................................................... 16
Table 2 - MacroMAXe frequency ranges .............................................................................................. 19
Table 3 – MacroMAXe installation tools................................................................................................ 25
Table 4 – MacroMAXe installation parts and kits .................................................................................. 26
Table 5 – MacroMAXe wall mount installation parts ............................................................................. 27
Table 6 – MacroMAXe pole mount installation parts ............................................................................ 27
Table 7 – MacroMAXe additional parts and kits ................................................................................... 27
Table 8 - Junction box (optional) ........................................................................................................... 29
Table 9 - DC Power input ...................................................................................................................... 46
Table 10 – Checklist for Procedure ....................................................................................................... 50
Page 8
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Warnings and Cautions
Human Exposure to Radio Frequencies
The MacroMAXe should be installed and operated from a minimum distance of 2.4 meters from your
body.
Radio Interference
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment on and off, the technician is encouraged to try to correct the interference by
performing one or more of the following measures:
¾
Re-orientate or relocate the receiving antenna
¾
Increase separation between the equipment and receiver
¾
Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected
Avoiding Radio Interference
¾
This transmitter must not be co-located or operating in conjunction with any antenna or
transmitter.
¾
Ensure a minimum of 1-meter separation between co-located BSRs.
Modifications
Any changes and modifications to this device that are not expressly approved by Airspan Networks
may void the user's authority to operate the equipment.
General
¾
Only qualified personnel should be allowed to install, replace, and service the equipment.
¾
The device cannot be sold retail, to the general public or by mail order. It must be sold to
dealers.
¾
Installation must be controlled.
¾
Installation must be performed by licensed professionals.
¾
Installation requires special training. The MacroMAXe radio and antenna should be
installed ONLY by experienced installation professionals who are familiar with local
building and safety codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may void Airspan's WiMAX product
warranty and may expose the end user or the service provider to legal and financial
liabilities. Airspan and its resellers or distributors are not liable for injury, damage or
violation of regulations associated with the installation of outdoor units or antennas.
Safety
1. Read this User Manual and follow all operating and safety instructions.
2. Keep all product information for future reference.
3. This product is supplied with a grounding power plug. Do not defeat this important safety
feature.
4. Warning: High voltages exist inside the product - do not remove the lid or base: No user
serviceable parts inside.
Page 9
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
5. CAUTION: DOUBLE POLE/NEUTRAL FUSING - Always replace the fuse with the correct
type and current rating.
6. Position the power cord to avoid possible damage; do not overload wall outlets.
7. Do not place this product on or near a direct heat source, and avoid placing objects on the
terminal.
8. Do not operate this device near water or in a wet location.
9. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the
power before cleaning.
10. Protect the terminal by disconnecting the power if not used for long periods.
11. Mount the terminal in a Telco rack on a stable horizontal surface.
12. The radio antenna units must not be located near power lines or other electrical power
circuits.
13. The radio transceiver must be properly grounded to protect against power surges and
accumulated static electricity. It is the user’s responsibility to install this device in accordance
with the local electrical codes: correct installation procedures for grounding of the transceiver
unit, mast, lead-in wire and discharge unit, location of discharge unit, size of grounding
conductors and connection requirements for grounding electrodes.
14. Installation of the transceiver must be contracted to a professional installer.
15. Disconnect Device. The socket outlet shall be installed near the equipment , easily
accessible and will act as the disconnect for the device.
16. When installed in the final configuration, the product must comply with the applicable Safety
Standards and regulatory requirements of the country in which it is installed. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.
Warning Symbols
The following symbols may be encountered during installation or troubleshooting. These warning
symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in
working with electrical equipment and radio transmitters. Familiarize yourself with standard safety
practices before continuing.
Electro-Magnetic Radiation
High Voltage
Service Information
Refer all repairs to qualified service personnel. Do not remove the covers or modify any part of
this device, as this will void the warranty.
Disconnect the power to this product and return it for service if the following conditions apply:
a. The terminal does not function after following the operating instructions outlined in
this manual.
b. Liquid has been spilled, a foreign object is inside, or the terminal has been exposed
to rain.
c.
Page 10
The product has been dropped or the housing is damaged.
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Locate the serial number of the terminal, antenna, and transceiver and record these on your
registration card for future reference. Use the space below to affix serial number stickers.
Also record the MAC address, located on the back of the terminal.
UL Information
- The equipment must be properly grounded according with NEC and other local safety code
requirements.
- Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected
to the grounding system of the building, as close to the point of cable entry as is practical.
Lightning Protection
WARNING: The following notes are general recommendations for the system. The wireless
equipment should be installed by a qualified professional installer and must follow local and national
codes for electrical grounding and safety. Failure to meet safety requirements and/or use of nonstandard practices and procedures could result in personal injury and damage to equipment. A direct
lightning strike may cause serious damage even if these guidelines are followed.
All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced current
from a near strike. Lightning protection and grounding practices in local and national electrical codes
serve to minimize equipment damage, service outages, and serious injury. Reasons for lightning
damage are summarized as:
- Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment.
- Lack of properly installed lightning protection equipment that can cause equipment failures from
lightning induced currents.
A lighting protection system provides a means by which the energy may enter earth without passing
through and damaging parts of a structure. A lightning protection system does not prevent lightning
from striking; it provides a means for controlling it and preventing damage by providing a low
resistance path for the discharge of energy to travel safely to ground. Improperly grounded
connections are also a source of noise that can cause sensitive equipment to malfunction.
A good tower grounding system disperses most of the surge energy from a tower strike away from the
building and equipment. The remaining energy on the RF cable shield and center conductor can be
directed safely to ground by using a lightning arrestor in series with the RF cable.
To limit the equipment damage due to a lightning strike, the following practices are recommended for
the wireless system:
- Provide direct grounding from the antenna mounting bracket, the radio and antenna and the
lightning arrestors to the same ground point at the base of the tower or a ground bus on the building.
Use the grounding screws on the antenna bracket and the radio and antenna for terminating the
ground wires. “Norway and Sweden: Grounding for unit considered on additional earth, not earth of
buildings”.
- Install one RF lightning protector between the radio and antenna in series with the RF cable.
- A lightning arrestor in series with the RF cable at the point of entry to the building.
- Laser Class I product use. Internal lasers comply with standards IEC 60 825-1, IEC 60 825-2, 21
CFR 1040.10, and CDRH.
- Install a lightning arrestor in series with the IF cable at the transceiver on the tower/mast.
Page 11
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
- The AC wall outlet ground must be connected to the same grounding system as the radio and
antenna lightning protectors.
Page 12
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
DECLARATION OF CONFORMITY
European Community, Switzerland, Norway, Iceland, and Liechtenstein
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC
English:
This equipment is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Deutsch:
Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden
Vorgaben der Richtlinie 1999/5/EU.
Dansk:
Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i
Directiv 1999/5/EF.
Español:
Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive
1999/5/EC.
Greek:
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ
ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
Français:
Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la
Directive 1999/5/EC.
Íslenska:
Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.
Italiano:
Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva
1999/5/EC.
Nederlands:
Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn
1999/5/EC.
Norsk:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EUdirectiv 1999/5/EC.
Português:
Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.
Suomalainen:
Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin
ehtojen mukainen.
Page 13
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Svenska:
Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta
bestämmelser i Direktiv 1999/5/EC.
Român:
Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei
1999/5/CE.
The Declaration of Conformity related to this product can be obtained
from product_management@Airspan.com
Page 14
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
FCC Notice
Federal Communication Commission Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his/her own expense.
Fixed and base stations transmitting a signal with an emission bandwidth greater than 1 MHz must
not exceed an ERP of 1000 watts/MHz and an antenna height of 305 m HAAT, except that antenna
heights greater than 305 m HAAT are permitted if power levels are reduced below 1000 watts/MHz
ERP.
GPS Compliance
The GPS is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC."
The GPS complies with the following EMC Common Regulatory Testing standards:
¾
EN55022: Radiated and Conducted Emissions
¾
CISPR 22: Class B
¾
EN 50081-1: Generic Emissions Class B
¾
EN 50082-1: Generic Immunity Class B
¾
EN 61000-4-2: Electrostatic Discharge Immunity
¾
EN 61000-4-3: Radiated RF EM Field Immunity Test
¾
EN 61000-4-4: Electrical Fast Transient/Burst Test
¾
EN 61000-4-6: Conducted Immunity
¾
EN 61000-4-8: Magnetic Field Immunity
Note: A GPS is required for synchronizing between TDD/FDD sectors.
Page 15
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Maximum Output TX Power
Figure 1 ‐ MacroMAXe Maximum Output TX Power
Caution: Do not set maximum output TX power to higher than local regulations.
Antenna Types
Table 1 ‐ Antenna Types ‐ Technical
Type
Frequency range
Gain
Manufacturer
Model number
+/-45° Polarized 90° Sector
Antenna - Quad Port Fixed Tilt
3.3 - 3.8 GHz
17.0 dBi
Alpha Wireless
AW3035
Manual Tilt Panel Antenna,
Dual Slant ± 45°
3.3 - 3.8 GHz
18.0 dBi
Argus
SSPX310M
Technologies Pty
Ltd.
9dBi Omni Directional
Antenna
3.3 - 3.8 GHz
9 dBi
MTI Wireless
Edge Ltd.
Omni Directional Base Station
Antenna
3.3-3.8 GHz
9.5 dBi
MARS Antennas & MA-WO36-10N
RF Systems Ltd.
8.5dBi Omni directional
Antenna
3.4-3.7GHz
8.5 dBi
MTI Wireless
Edge Ltd.
MT402009/N/A
10.5dBi Omni Directional
Antenna
3.3-3.8GHz
10.5 dBi
MTI Wireless
Edge Ltd.
MT-403017/N
Double Dual Slant - Base
Station Antenna - 65º
3.3 – 3.8 GHz
17.5 dBi
MTI Wireless
Edge Ltd.
MT 404081/ND
BLADE ANTENNA
3.6-4.0 GHz
2.0 dBi
EUROPEAN
SBA-3800ANTENNAS LTD. D1/1040
Page 16
Commercial in Confidence
MT-402005/N
UGD-D00181 Rev E
MacroMAXe Installation Guide
1 About this Guide
This section discusses the purpose, intended audience, conventions, referenced documentation and
organization for this guide.
1.1 Purpose
This guide provides the workflow and step-by-step procedures for Installing the MacroMAXe. These
procedures include:
¾
Verify Prerequisites
¾
Install the MacroMAXe
¾
Connect and Manage Cables
¾
Set Power System
1.2 Intended Audience
This guide is intended for persons who are responsible for Installing the MacroMAXe. These persons
should have a working knowledge of the WiMAX system.
1.3 Conventions
This document uses the following informational conventions.
Icon
Description
Checkpoint: Marks a point in the workflow where there may be an exit or branch
to some other procedure. At each Checkpoint the reason for an exit or branch is
given along with specific directions to locate the entry point in the other
procedure.
Reference: Gives a resource in the workflow that may be needed to complete a
procedure along with specific directions to use the resource.
Caution: Describes a possible risk and how to lessen or avoid the risk.
Advice: Provides a recommendation based on best practice.
Note: Provides useful information.
1.4 Referenced Documentation
¾
MacroMAXe Product Description
¾
Job Sheet
1.5 Organization of this Guide
This guide is organized into the following Sections:
Page 17
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Page 18
About this Guide
Introduction
Get Started
Verify Prerequisites
Install the MacroMAXe
Connect and Manage Cables
Set Power System
Appendixes [Sample Job Specification, Troubleshooting, Glossary of Terms, Installation
Checklist, Contact information and Revision history]
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
2 Introduction
This section provides a descriptive overview of the product and its place in the product suite.
2.1 MacroMAXe
MacroMAXe is a highly integrated macro-cell base station with all-in-one packaging of RF and baseband components. MacroMAXe includes integrated Quad receiver / Dual transmitter to support two
channel diversity and MIMO. It is available as an all outdoor solution for Mobile WiMAX applications
to minimize physical footprint and operator expense.
MacroMAXe is an outdoor radio that is mounted outside on a pole or wall. MacroMAXe is available in
numerous frequency bands and in numerous channels see: MacroMAXe Frequency Ranges.
MacroMAXe is managed by an SNMP-based network management system (Netspan) using standard
and proprietary MIBs. Basic management can be performed using any standard Web browser.
Note: For management refer to MacroMAXe Commissioning documentation.
2.2 MacroMAXe Frequency Ranges
The table below lists the frequency range of MacroMAXe variants currently available. This table will
grow as more variants become available.
Table 2 ‐ MacroMAXe frequency ranges
Band
Region Lower Frequency Upper Frequency Channel Bandwidth Duplex
3.6 GHz
Generic 3650 MHz
3675 MHz
¾
5MHz
¾
7MHz
¾
10MHz
TDD
2.2.1 Architecture
A highly flexible and scalable WiMAX Base Station, the MacroMAXe is capable of supporting Mobile
WiMAX profiles across multiple frequency bands.
Note: The following is for illustration only; actual layout may differ as
infrastructure is installation-specific.
Note: MacroMAXe must be properly grounded according with NEC and other
local safety code requirements.
Page 19
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 2 – MacroMAXe Hardware Components
Note: MacroMAXe can also be connected via a LAN Switch for greater Failsafe
protection.
Note: Illustration above is of single Ethernet cable for connection.
Note: Illustration above displays remote GPS antennae option.
The MacroMAXe is a fully integrated all outdoor base station sector that contains all RF, Baseband,
GPS Synchronization and 3-sector aggregation functionality. In one box it comprises the following
functional elements:
¾
Quad Receiver / Dual Transmitter
¾
SDR Card
¾
Ethernet Switch
¾
GPS
Page 20
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 3 – MacroMAXe Functional Components
Page 21
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
3 Getting Started
3.1 Workflow of Installation
The Workflow to install the MacroMAXe is shown in the following diagram:
Figure 4 – Workflow of Installation
Page 22
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
3.2 MacroMAXe Installation Checklist
Plan the installation of the MacroMAXe by using the Installation Checklist, which you can find as a
removable job aid in Appendix A for this guide.
Page 23
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
4 Verify Prerequisites
Prior to installing the MacroMAXe, verify the required safety, power, tools, parts and components.
Reference: Set up requirements for the installation are detailed in the Job Sheet.
To see the suggested contents of a Job Sheet for a site, see Appendix A for this
guide
4.1 Verify Safety Requirements
Read and follow all warning notices and instructions marked on the product or included in this manual.
When installed in the final configuration, the product must comply with the applicable Safety
Standards and regulatory requirements of the country in which it is installed. If necessary, consult
with the appropriate regulatory agencies and inspection authorities to ensure compliance.
Ascertain the radiation hazards when working in an environment close to other antennas and
Electromagnetic fields, e.g. working on towers with other microwave transmitters etc. and act
accordingly.
4.1.1 Warning of Hazardous Voltages
On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power.
Remove metal jewelry that could come into contact with AC power.
On DC sections, short circuiting the low voltage, low impedance circuits can cause severe arcing that
may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits.
Note: Airspan products do not contain hazardous substances (as defined in UK
Control of Substances Hazardous to Health Regulations 1989 and the Dangerous
Substances Regulations 1990). At the end of any Airspan products life cycle, the
customer should consult with Airspan to ensure that the product is disposed of in
conformance with the relevant regulatory requirements.
Caution: Any modifications to this device not expressly authorized by the
manufacturer could void the users authority to operate this device.
Page 24
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
4.2 Verify Installation Requirements
4.2.1 Verify the Tools
Tool
Large Crosshead Screw driver Phillips # 3 or Pozidrive # 3
Small flat blade screwdriver
Medium flat blade screwdriver
13mm or 1/2 inch open ended spanner
10mm or 13/32 inch open ended spanner
Wire strippers
Wire cutters
Ring terminals crimp tool
RJ45 crimp tool
Table 3 – MacroMAXe installation tools
4.2.2 Verify the Parts and Kits
MacroMAXe Base Station parts
Consisting of
1 x MacroMAXe unit
Base station unit
3 x RJ45 Weatherproof Connector
Covers
Weatherproof connector covers for use with standard cat 5
RJ45 network connections.
1 x mains cable 14AWG x2 (ordered
separately)
30 meter lead with M17 3 pole plug
When distance from outdoor Power supply to Base Station is over 30 meters additional power cable
must be connected via a junction box (ordered separately) for total distance of up to 130 meters.
14AWG x2 (ordered separately) – up to 40 meters
12AWG x6 (ordered separately) – up to 100 meters
1 x Ethernet RJ45 environmental
shroud
LTW IP68 or Amphenol environmental connector
1 x Sunshield fixing kit (optional)
(ordered separately)
4 x M6 screws
4 x M6 plain washers
4 x M6 spring washers
Page 25
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
MacroMAXe Base Station parts
Consisting of
1 x MacroMAXe installation mount kit
(ordered separately)
8 x male-male threaded studs M8
24 x M8 plain washers
16 x M8 spring washers
8 x M8 nuts
1 x earth kit
1 x M6 screws
1 x M6 washers
1 x M6 spring washers
1 x M6 nut
1 x GPS antenna kit
(ordered separately)
1x GPS Antenna. An active GPS antenna which, by using the
appropriate mounting bracket, can be used with MacroMAXe
for network synchronization.
For mounting directly to the top of MacroMAXe, this GPS
Antenna should be used in conjunction with MacroMAXe GPS
Antenna Top Mounting Kit.
When mounting remotely from the base station units, this
antenna should be used in conjunction with the Remote GPS
Antenna Mounting Bracket & 5m or 16m GPS Cable RG58
TNC-TNC.
30cm or 16m Cable Assembly. 30cm or 16m RG58 cable.
Connects remote mounted GPS Antenna (GPS-ANT-1) to the
MacroMAXe via TNC connectors.
Table 4 – MacroMAXe installation parts and kits
Parts
Wall Plate
Top Hanger
Lower Hanger
Page 26
Images
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Parts
Images
GPS Antenna
mounting
bracket
Handle
Table 5 – MacroMAXe wall mount installation parts
Parts
Images
Note: Additional to Wall mounting
kit.
Top & Lower
Pole Strap
(x2) for 120 >
230 MM
Note: Additional to Wall mounting
kit.
Pole bracket
for 60 > 120
MM
Table 6 – MacroMAXe pole mount installation parts
Additional Common Accessories
(not provided by Airspan)
Spare RJ45 connectors
Cable ties
Ring terminal for earth strap. M5 / M6
Earth strap cable (4-6 mm) (yellow and green cable)
Weatherproof / Outdoor mains cable splice kit or
termination box.
Table 7 – MacroMAXe additional parts and kits
Optional Junction Box
Consisting of
1 x Junction box (ordered separately)
Junction box
Page 27
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Optional Junction Box
Consisting of
1 x PG11 Weatherproof gland (connector),
included with junction box
Weatherproof connector
1 x PG16 Weatherproof gland (connector) ),
included with junction box
Weatherproof connector
1 x PG29 Weatherproof gland (connector) ),
included with junction box
Weatherproof connector
Additional power cable
14AWG x2 (ordered separately) – up to 40
meters
12AWG x6 (ordered separately) – up to 100
meters
2x mounting bracket(s) for pole and wall
mounting
Bracket (x2)
2x pole bands (stainless steel), as required,
supplied.
60 – 80 mm (2 ¼”)
2x pole bands (stainless steel), as required,
supplied.
80 – 100 mm (3 1/2”)
Mounting screws – for mounting brackets to
junction box.
EJOT WN1412 – K50 x 12 – 4 supplied.
Wall mounting fasteners
Hole size = 7 mm (not supplied - customer
responsibility)
Page 28
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Optional Junction Box
Consisting of
Sufficient cable wires ties, as required
(not supplied - customer responsibility)
Table 8 ‐ Junction box (optional)
4.2.3 Verify Components
MacroMAXe is in an all outdoor enclosure that measures 52.7 cm in height, 34.7 cm in width, 15.6 cm
in depth and weighs about 17kg. The unit is shown below from the Ethernet termination and RF port
end views respectively.
Figure 5 – MacroMAXe Base Station Unit, Ethernet termination
Page 29
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 6 – MacroMAXe Base Station Unit, RF ports
RF Ports for antenna connections are N-Type Female connectors located on the top of the
MacroMAXe enclosure. Adjacent to these are SMA connectors used for RF monitoring purposes
during installation / maintenance. For normal operation, these are covered with a weatherproof cap.
A 80cm or 16 m RG58 cable connects a remote mounted GPS Antenna to the MacroMAXe by way of
TNC connectors. The cable assembly for the remote GPS antenna is shown below.
Figure 7 – MacroMAXe Cable Assembly for GPS Antenna
Figure 8 ‐ Lightning/Surge protector
Page 30
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
4.2.3.1
Junction Box (Optional)
The Junction box (optional) is an outdoor enclosure that measures 152 mm in height, 170 mm in
width and 95 mm in depth. The unit is shown below with the pole mounting bands assembled. The
Junction box is required when the distance from the outdoor Power supply to Base Station is over 30
meters for total distance of up to 130 meters.
Note: If – 48 volt DC can be verified and guaranteed the Junction box may not be
required. Contact customer support to determine.
Figure 9 ‐ Junction box with pole assembly
Page 31
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
5 Install MacroMAXe
Install the MacroMAXe base station by pole mount, wall mount, or single point. The MacroMAXe can
be deployed as a remote radio head (RRH) connected to a pair of single (usually vertically polarized)
or single dual independently mounted antennas via standard RF coaxial cables. Antennas are
positioned with up to 10 wavelengths horizontal separation to give optimal Downlink and Uplink MIMO
performance.
5.1 Pole mount configuration
The following image shows the pole mount assembly.
Figure 10 – Pole Mounted MacroMAXe Assembly
To mount the MacroMAXe in the pole mount configuration (for poles 120 > 230 mm), perform
the following steps:
1. Attach the two (2) PM-323 pole straps to the pole at the heights required to attach the
MacroMAXe.
2. Fasten the mounting brackets to the pole straps; position the tabbed strap lower on the pole
with the tab facing down.
3. Lift the enclosure and place the screws through the head clearance holes and position the
unit so that the top mounting holes retain the unit.
Caution: This unit weighs 17 kg, take care when lifting.
4. Screw the bottom two the M8 screws and washers into the two standoff fittings at the bottom
of the MacroMAXe enclosure.
5. Attach Base Station and loosely tighten all screws.
6. Tighten all fixing screws.
Page 32
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 11 – Pole Mounted MacroMAXe
To mount the MacroMAXe in the pole mount configuration (for poles 60 > 120 mm), perform
the following steps:
1. Attach the two (2) pole brackets (shown above) to the pole (with the threaded holes facing up)
at the heights required to attach the MacroMAXe.
2. Tighten upper pole bracket and hand tighten (loosely) the lower pole bracket for later
adjustment.
Caution: This unit weighs 17 kg, take care when lifting.
3. Lift and align the MacroMAXe unit and place the screws through the head clearance holes
and position the unit so that the top mounting holes retain the unit and loosely tighten all
screws.
4. Tighten all fixing screws.
5.2 Wall mount configuration
The following image shows the wall mount assembly.
Page 33
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 12 – Wall Mounted MacroMAXe
The following diagram depicts the Wall Plate Details.
Figure 13 – Wall Mounted MacroMAXe Wall Plate Details
To mount the MacroMAXe in the wall mount configuration, perform the following steps:
Page 34
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
1. Attach the Wall Plate to the wall at the height required to attach the MacroMAXe.
2. Fasten the Hangars to the rear side of the MacroMAXe enclosure, position the niched Hangar
so it is lower on the wall with the niche facing down.
3. Lift the enclosure and place the screws through the head clearance holes and position the
unit so that the top mounting holes retain the unit.
Caution: This unit weighs 17 kg, take care when lifting.
4. Screw the bottom two screws and washers into the two standoff fittings at the bottom of the
MacroMAXe enclosure.
5. Tighten all fixing screws.
5.3 Install MacroMAXe Antennas
Use this procedure to install a linear dual slant antenna for the MacroMAXe in the mast mount
configuration.
Figure 14 – MacroMAXe External Antenna Configuration
Note: Separate Antenna distance according to RF planning.
Page 35
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
5.3.1 Install Dual Slant Antenna
Figure 15 ‐ MacroMAXe Antenna Dual Slant Mast Mount Configuration
To mount the dual slant antenna for the MacroMAXe in the mast mount configuration, perform
the following steps:
1. Attach the Antenna brackets to the top and bottom of the radome.
2. Attach the tilt arm to the top bracket of the radome.
3. Fasten the ends of the adjustable pipe mounts to the top and bottom brackets of the radome.
4. Lift the radome and place the screws through the adjustable pipe mounts and position the
radome so that the top mounting holes retain the unit.
5. Screw the bottom two screws and washers into the two standoff fittings at the bottom of the
radome assembly.
6. Tighten all fixing screws.
7. Attach, connect and secure antenna RF cable between the antenna and the appropriate
MacroMAXe Antenna RF connection on the top of the unit.
Page 36
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
5.3.2 Install Quad Slant Antenna
Figure 16 – MacroMAXe Antenna Quad Slant Mast Mount Configuration
To mount the Quad slant antenna for the MacroMAXe in the mast mount configuration,
perform the following steps:
1. Attach the Antenna brackets to the top and bottom of the radome.
2. Attach to the top bracket of the radome.
3. Fasten the ends of the adjustable pipe mounts to the top and bottom brackets of the radome.
4. Lift the radome and place the screws through the adjustable pipe mounts and position the
radome so that the top mounting holes retain the unit.
5. Screw the bottom two screws and washers into the two standoff fittings at the bottom of the
radome assembly.
6. Tighten all fixing screws.
7. Attach, connect and secure antenna RF cable between the antenna and the appropriate
MacroMAXe Antenna RF connection on the top of the unit.
5.3.3 Antenna Mounting Clamps for Dual and Quad Slant Antennae
The following are some adjustable antenna mounting clamp options for both Dual and Quad Slant
antenna scenarios.
Page 37
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 17 ‐ Adjustable Mounting Kit, with Snaplock Stainless Steel Bands
Page 38
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 18 ‐ Adjustable Mounting Kit, with ‘V’ Blocks
5.4 Optional Mounting Antenna on MacroMAXe
Either Antenna shown can be mounted on the MacroMAXe unit or mast mounted.
Note: The sunshield kit is required for this type of assembly. Contact your
supplier to order.
5.4.1 Variable Tilt Antenna
There is a Variable Tilt Antenna available for mounting on the MacroMAXe. The antenna maybe
connected directly to the MacroMAXe with no need for physical tilting of the antenna.The Manual
Electric Tilt (MET) antenna has a rotating nut that adjusts a threaded rod which moves in and out
while displaying a tilt scale, as shown below.
Page 39
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 19 ‐ Variable tilt antenna
Figure 20 ‐ Antenna mounted on MacroMAXe
5.5 GPS Antenna Assembly
To mount the GPS antenna directly on the MacroMAXe:
1. Route the RG58 cable through the flat washer and the 2 nuts (supplied).
2. Position the RG58 cable below the mounting hole on the GPS antenna mounting bracket, as
shown below:
Page 40
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 21 ‐ GPS cable assembly prior to mounting
3. Hand-tighten the RG58 cable TNC (90°) connector to the mating connector on the GPS
antenna.
Figure 22 ‐ Attach GPS antenna to RG58 cable
4. Slide the flat washer up to the underside of the mounting bracket, then thread 1 nut onto the
GPS antenna threaded base and tightened.
5. The second nut is then secured and tightened against the first nut to create a clamp load
against the first nut, as shown below:
Figure 23 ‐ GPS antenna assembled on bracket
Page 41
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
5.6 Install Junction Box (Optional)
Note: Contact Airspan customer-service to determine whether junction box
installation is required. Installation may be required, depending on the distance
between the external power-supply and the BS, as well as the minimum voltage
supplied by the power-supply.
The Junction box (optional) can be pole-mounted or wall-mounted.
Warning: Mount the junction box in an orientation such that the cable ports
(located on the bottom) face downwards. This prevents rain water from
settling on the ports, and thereby, avoiding damage.
Figure 24 ‐ Junction box with mounting brackets assembled
For either mounting method, the mounting bracket provides mounting holes (displayed below):
Figure 25 ‐ mounting bracket (2 required)
5.6.1 Junction Box Installation
To install the junction box:
1. Prior to installation connect the 2 mounting brackets to the back of the junction box fastening
to the provided holes. The wall mounting hole orientation should be towards the outer edges
of the junction box.
2. Remove the junction box’s cover, leaving the rubber gasket in place.
3. Prepare the cables for connection by performing the following:
a. Strip about 25.4 mm (1 inch) of the outer jacket of the cable to expose the wires.
b. Using a wire-stripping tool, expose about 6.3 mm (0.25 inch) of each of the wires by
stripping the wires’ insulation.
Page 42
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
4. Determine which cable entry holes are to be used and remove the appropriate plug.
Cable Entry hole determination
Gland hole PG11 (M18) for cable terminating at MicroMAXe
Gland hole PG29 (M36) for cable 12AWG x6
Gland hole PG16 (M22) for cable 14AWG x2
Note: Save the rubber grommets from the plugs to be used on the weatherproof
glands (connectors).
5. Remove the nut on the weatherproof connector and slide the rubber grommet onto the
threaded shaft.
6. Set the weatherproof connector into the hole and from inside the box, thread the included nut
onto the shaft until tight.
7. Insert the exposed wires into the relevant screw-type terminal block (+ to + and – to –) and
then secure them in place by tightening the screw of each terminal.
8. Fasten the Junction box onto the pole or wall as required within the required distance of the
MacroMAXe enclosure.
9. Perform the same procedure (steps 3-7) with the cable terminating in the in the MacroMAXe
enclosure.
10. Open the connector clamp collar and feed about 101.6 mm (4 inches) of cable from the
MacroMAXe through it and into the box. Tighten the collar around the cable, forcing the seal
to compress around the cable.
11. Replace the cover by using the four (4) screws, ensuring the gasket (for weatherproofing) is
firmly in place on the rim of the cover.
Note: It is important to provide strain relief and drip loop for the cables. Create a
drip loop and strain relief using cable tie, to tie cable to pole, as displayed in the
figure below:
Page 43
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
Figure 26 ‐ MacroMAXe assembly with optional junction box
Page 44
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
6 Connect and Manage Cables
The Ethernet cable is connected to the MacroMAXe using a standard RJ45 connector protected by a
harsh environment protective casing.
Figure 27 – Ethernet connector cable termination
6.1 Assemble Ethernet Connector
1. Pass the Cat 5 cable through the seal, front connector, body and tail nut of the environmental
connector casing as shown above.
2. Paste the front seal on the collar of the connector body.
3. Terminate the Ethernet cable with an RJ45 connector plug.
4. Seat the RJ45 connector plug securely into the body cavity.
5. Tighten the tail nut on to the body forcing the seal to compress around the cable.
Figure 28 – Ethernet environmental connector assembly
Page 45
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
7 Set Power System
Hazardous voltage! Before working, ensure that the power is removed from the
power connection cables. When the system is powered on, do not touch the
power terminals.
7.1 Power Input - DC
Each unit is provided with a 3/10/30 meter 48 volt power cable terminated with a male connector at
one end and a female connector at the other.
Connection
Color
Neutral
(Cold)
Blue
Live (Hot)
Brown
Table 9 ‐ DC Power input
Caution: It is important that the power connector is attached at the correct end
(see illustration below) or damage to the connector/equipment will result.
Figure 29 – DC Power connector cable
Page 46
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
8 Appendix A
8.1 Review Job Sheet
The Job Sheet should include the following information:
¾
BS location and identity.
¾
Whether the system is required to be locked to a GPS timing reference.
¾
A BSID is required for each BS TRx. This should be in a format xxxxxx:xxxxxx where x is a
decimal digit.
¾
Network configuration information for the BS TRx.
Traffic Port: Not applicable.
IP Address: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
ƒ Netmask: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
ƒ Default Gateway: Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
ƒ Management VLAN: Specified as either Untagged or Tagged
ƒ Management VLAN Tag: Should only be set if Management VLAN is set to Tagged
ƒ Management IP Mode: Specified as Static IP Address or Obtain IP Address via DHCP
ƒ Ethernet Mode: Specified as Auto-negotiate or Fixed
ƒ Ethernet Rate: Need only be configured if Ethernet Mode is set to Fixed, specified as
10M or 100M.
ƒ Ethernet Duplex: Need only be configured if Ethernet Mode is set to Fixed, specified as
Full or Half.
SNMP configuration information. This will allow events from the BS to arrive at the
specified Netspan server. This will include the following information:
ƒ
ƒ
¾
¾
Read Only Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under Server on Netspan left hand panel).
ƒ Read Write Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
ƒ SNMP Port Number: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
ƒ IP Address: This specifies Netspan IP address (found under Server Global
Configuration, which is under Server on Netspan left hand panel).
ƒ Community: Normally specified to the same value as for Read Only Community.
ƒ Port Number: Normally specified to a value of 9023.
Whether the Primary Master or the Secondary Master manages the GPS module.
¾
NTP configuration. This specifies a list of NTP servers.
ƒ
Page 47
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
9 Appendix C – Glossary of Terms
AAA
Authentication, Authorization and Accounting
AAS
Advanced Antenna System
AF
Application Function
ARQ
Automatic Repeat reQuest
ASN
Access Service Network
ASN GW
ASN Gateway
ATCA
Advanced Telecommunications Computing Architecture
BS
Base Station
BWA
Broadband Wireless Access
CHAP
Challenge Handshake Authentication Protocol
CPE
Customer Premises Equipment
CQI
Channel Quality Indicator
CSN
Connectivity Service Network
DSM
Digital Surface Model
DTM
Digital Terrain Model
EAP
Extensible Authentication Protocol
FA
Foreign Agent
FBSS
Fast Base Station Switching
FDD
Frequency Division Duplex
GUI
Graphical User Interface
HA
Home Agent
H-ARQ
Hybrid Automatic Repeat reQuest
HO
Handover/Handoff
IMS
IP Multimedia Subsystem
IP
Internet Protocol
IPsec
IP security
LR
Location Register
MAC
Media Access Control
MDH
Macro Diversity Handover
MIMO
Multiple Input Multiple Output
MIP
Mobile IP
MRC
Maximal Ratio Combining
MS
Mobile Station
NAP
Network Access Provider
NAS
Network Access Server
NLOS
Non Line of Sight
NSP
Network Service Provider
Page 48
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
NWG
Network Working Group
OBSAI
Open Base Station Standard Initiative
OFDMA
Orthogonal Frequency Division Multiplexing (Multiple Access)
PA
Paging Agent
PAAA
Proxy AAA
PC
Paging Controller
PF
Policy Function
PHY
PHYsical Layer
PMIP
Proxy MIP
PPP
Point-to-Point Protocol
RADIUS
Remote Authentication Dial In User Service
RRA
Radio Resource Agent
RRC
Radio Resource Controller
RRM
Radio Resource Management
SAS
Smart Antenna System
SDR
Software Defined Radio
SFA
Service Flow Authorization
SFM
Service Flow Management
SIM
Subscriber Identity Module
SIP
Session Initiation Protocol
SOFDMA
Scalable Orthogonal Frequency Division Multiplexing (Multiple Access)
STC
Space Time Coding
TDD
Time Division Duplex
VoIP
Voice over IP
X.509
ITU-T standard for PKI digital certificates
Page 49
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
10 Appendix D – Installation Checklist
The Checklist below gives the high-level steps in the Workflow for this procedure. Detach or print this
page to use as a job-aid for completing the actions this procedure requires.
Procedure
Actions
Outcome
1. Verify Prerequisites
Verify safety
requirements
All requirements are in
place for a successful
commissioning of
MacroMAXe.
Verify installation
requirements
2. Install MacroMAXe
Pole mount configuration
Wall mount configuration
Install MacroMAXe
antennas
3. Connect and manage
cables
Assemble Ethernet
connector or
Disassemble Ethernet
connector, then
Assemble LTW Ethernet
connector
4. Set power system
Power input
Power output
Table 10 – Checklist for Procedure
Page 50
Commercial in Confidence
UGD-D00181 Rev E
MacroMAXe Installation Guide
11 Appendix E
11.1 Revision History
Revision
Originator
Date
Description
Draft 1
D. Cann
2-2009
Initial document
Draft B
M. Falik
3-2009
Additional content &
template changes
Rev A
M. Falik
10-2009
Additional content
Rev B
M. Falik
10-2009
Corrected Graphics +
Additional content
Rev C
M. Falik
12-2009
Added Junction box
data
Rev D
M. Falik
12-2009
Additional content
Rev E
M. Falik
02-2010
Frequency ranges and
latest support
11.2 Contact Information
Customer Service Help-Desk for customer service emergency
Airspan Networks have introduced the Airspan Tracker application to enable prompt and efficient
Customer Support services.
If you do not have an Airspan Tracker account, please obtain login credentials by filling-in the form in
the main page www.airspan.com/Support Register New Account
Worldwide Headquarters:
Airspan Networks Inc.
777, Yamato Road, Suite 310,
Boca Raton, FL 33431, USA
Tel: +1 561 893 8670
www.airspan.com
Feedback:
To provide feedback on this document, please send comments to the following email
address: DocumentFeedback@airspan.com
Page 51
Commercial in Confidence
UGD-D00181 Rev E

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Producer                        : Acrobat Distiller 8.2.0 (Windows)
Creator Tool                    : Acrobat PDFMaker 8.1 for Word
Modify Date                     : 2010:03:09 14:43:22+02:00
Create Date                     : 2010:03:09 14:40:30+02:00
Metadata Date                   : 2010:03:09 14:43:22+02:00
Format                          : application/pdf
Creator                         : Meyer Falik
Title                           : MacroMAXe Installation Guide
Description                     : Airspan
Subject                         : SR 9.0 Rev E ZL special
Document ID                     : uuid:395a820e-3f7d-4a34-84e5-ad2c6fc19436
Instance ID                     : uuid:b63b5d63-412a-4ff6-968f-1614d4906b9d
Company                         : Airspan Networks
Page Count                      : 51
Page Layout                     : OneColumn
Author                          : Meyer Falik
Keywords                        : SR, 9.0, Rev, E, ZL, special
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PIDMMAX3605

Navigation menu