REMOTE KEYPAD (KP-7)
z Identifying the parts:
1.
Tx LED
2.
ACTIVE LED
3.
10 Numeric keys
4.
“ + ” button – to send Emergency code
5.
S ” button – to send Status code
“○
6.
“
” button – press after PIN Code to Part Arm the system
7.
“
” button –press after PIN Code to Arm the system
8.
“
” button – press after PIN to Disarm the system
9.
“♪” button – to send Chime code
10.
Tamper Switch
z LED Indicator:
z ACTIVE LED (Green):
z When idle, both LED’s are off.
After any key press, the Green LED goes on for 5 seconds indicating that
KP-7 is active.
z However if the Green LED flashes during operation instead of being on steadily, this is an indication of a low
battery.
z The LED turns off after successful completion of a valid keystroke sequence, or when the pause in between
key stokes is longer than 5 seconds.

" When the Green LED turns off before a valid keystroke sequence is completed, the previous entered keys
are ignored.
z Tx LED (Red):
z On for 2 seconds when transmitting.
z In tampered condition, the Red LED will flash whenever KP-7 is used.
z Power:
KP-7 uses 3 “AAA” alkaline batteries as its power source.
domestic environment.
When KP-7 enters low battery status, a low battery signal will be sent out by KP-7 only after 20 regular signal
transmissions have been consecutively sent in low battery mode.
Its typical battery life is 5 years in a normal
z Supervision:
Upon inserting the batteries for the 1st time, the KP-7 will promptly send out a supervisory signal.
Thereafter, it continues to transmit supervisory signal periodically at intervals of 30 to 50 minutes.
Use of the keypad will re-start the time count 30 to 50 minutes for next supervisory signal.
z Power Saving Feature:
When idle, KP-7 is in “standby” mode and uses no power.
any key is pressed.
KP-7 AlarmForce
It will activate and “wake-up” for 5 seconds where
2007.3.23
z
After 5 seconds of key inactivity, the power goes off and it returns to Stand-by mode.
Upon completion of a command input, the power goes off and KP-7 returns to Stand-by mode.
z Tamper Protection:
KP-7 is protected against any attempt to open the lid or to detach KP-7 from its mounting surface.
In tampered condition, KP-7 will emit a beep every 30 seconds as warning to the user .
In tampered condition, the Red LED will flash whenever KP-7 is used.
z Mounting KP-7:
Break through the two or four knockouts where the plastic is thinner
Using the holes of the base as a template, drill holes in the surface
Insert the wall plugs if fixing into plaster or brick
Screw the base to the wall
Ensure that the tamper switch spring protruding through the back is fully depressed by the mounting surface.
Fix the lid with the screw and clips to the base
z Programming KP-7:
1. Remove the cover by loosening the fixing screw
2. Insert three “AAA” batteries
3. The Red LED indicator will flash briefly while components initialize and supervision code will be sent out.
z Functions Overview:
Dual Key Alarm Features:
„ Arm
¾
PIN code + “ARM”
„ Panic Alarm
¾
“1” + “3” simultaneously
„ Part Arm
¾
PIN code + “HOME”
„ Fire Alarm
¾
“4” + “6” simultaneously
„ Disarm
¾
PIN code + “OFF”
„ Emergency Alarm
¾
“7” + “9” simultaneously
„ Chime
¾
“♪ ”
„ Emergency
¾
“+”
„ Status
S”
¾
“○
This device complies with Part 15 of the FCC Rules and RSS-210 of Canada. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution :
To assure continued compliance, any changes or modifications not expressly approved by the party responsible for
KP-7 AlarmForce
2007.3.23
compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables
when connecting to computer or peripheral devices).
KP-7 AlarmForce
2007.3.23

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2007:04:03 12:49:22+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2007:04:03 12:49:22+08:00
Format                          : application/pdf
Title                           : Microsoft Word - KP-7 315M for Alarmforce 20070323.doc
Creator                         : Jessica
Document ID                     : uuid:9489d615-03d1-4f28-b41d-c5dfa3fa4338
Instance ID                     : uuid:4d8075d8-e7fb-4c91-bdbe-5457544683f8
Page Count                      : 3
Author                          : Jessica
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SJLKP7315

Navigation menu