Aleph America QT-001-00 Field Disturbance Sensor User Manual II QT Series US2

Aleph America Corporation Field Disturbance Sensor II QT Series US2

Contents

Users Manual

Quad-Tech Intrusion DetectorsQT Series Select an installation height between 7 ft. (2.1 m) and 8.5 ft. (2.6 m).  Optimum mounting height is 7.5 ft. (2.3m).  Avoid aiming the intrusion detectortowards windows, areas exposed to direct sunlight, and heating/cooling outlets.  For best performance, position the detector so its field of view isunobstructed, and the anticipated path of an intruder will cross the PIR beam pattern.Wire the detector to the control panel using 18 to 22 AWG conductor, standard non-shielded cable.  Avoid running alarm wiring parallel to AC wiring. Wiring knockouts and wire channel are provided in the rear cover for unobtrusive wiring.  Terminal block configuration is shown in Fig. 3, below.Prior to mounting the detector, configure jumper settings as required (see Fig. 2, below).Pulse Count: When Pulse Count jumper is covering both pins, PC is set at 2: two to three normal steps are required to trigger an alarm.  Parking thePC jumper on one pin (or removing jumper) sets PC to 4: four to five steps will trigger an alarm. LED Enable:  When Jumper is covering both pins, the Alarm LED is enabled.  The Alarm LED glows through the lookdown lens when an alarm issignaled at the Alarm Output terminals.  LED brightness automatically increases when light level in detection area is high.  As room light dims so doesthe LED brightness.  Parking the jumper on one pin (or removing jumper) disables the Alarm LED but has no effect on the alarm output.& SettingsInstallationDescription   Available with 40-foot and 60-foot protection patterns, QT Series intrusion detectors provide high quality PIR+microwave security at an outstanding value. Front RearWiring KnockoutsCorner Mount    KnockoutsWire ChannelCover Latch ScrewLookdown LensMounting KnockoutsWide Angle LensFig. 1:  Cover Component LayoutTerminal ConfigurationNC  CALARM TAMPERNC C-+Fig. 3:  Wiring ConfigurationFig. 2:  PCB LayoutCompliance Information: Separate the front and rear covers by first backing out the cover latch screw three to four full turns.  Then use a small screwdriver or similar tool to releasethe cover latch.  To remove the PCB, push the PCB latch away from the board while grasping a terminal block and pulling the PCB out of the cover.  Donot pull on the microwave module.  Refer to Figures 1 and 2, below.performance.Microwave Sensitivity Adj.Microwave Sensitivity: Microwave Sensitivity Adjustment is set to the fully clockwise position at the factory for maximum sensitivity (range).Turn the Microwave Sensitivity Adjustment (Fig. 2) counter-clockwise to reduce sensitivity.  Setting the adjustment to minimum (fully counter-clockwise)reduces sensitivity to approximately one-third of its maximum value.30% ~ 100%Microwaves can “see” through walls, so in some cases, such as installation in a small room, it may be desirable to reduce microwave sensitivity.AdjustmentsAleph’s unique “QT” signal processing evaluates PIR and microwave information while factoring in ambient temperature and light for superior “Quad-Tech”(Factory maskedfor Pet Immunity)(furniture, stairs...) may jeopardize the pet immunity feature of the detector.Pet Immunity:  For installations where pet immunity is needed, mounting height should be no lower than 7.5 ft. (2.3m).  Animal access above floor levelTo ensure Pet Immunity function, do not point detector towards stairways, furniture or room fixtures to which animals have access. Min. Max.FeaturesTableX X X XX X XXXQT-40  QT-40SL  QT-60  FeatureModel SwitchTamper LightSelectOn/OffLEDCountPulseImmunity60 lb. PetProtectionLightningXX X X XXSelectMax. input current: 15 mA; SL model 30 mASecurity Comp.Temp.XXXSL Front / SL Down: -- Included on Model QT-40SL -- These jumpers independently enable and disable the “Front” and “Down” Security Light (SL)functions.  SL Front controls a single white LED which shines through the front (wide angle) lens.  SL Down controls two white LEDs which shine throughthe lookdown lens.  When enabled, Security Light operates for at least 10 seconds when motion is detected and room light is dim.  Continued motionwill cause Security Light to remain on until approximately 10 seconds after motion ceases.Jumper SettingsLED EnableJumper installed on both pins = LED ENABLEDJumper removed = LED OFFPulse CountJumper installed on both pins = PC 2Jumper removed = PC 4TamperTerminal BlockTamper SwitchTamper Terminal BlockALARM TAMPERLED ENABLEPULSECOUNTAlarm LEDPCB latch-+SLFRONTSLDOWNSecurity Light Enable*Jumper installed on both pins = SL ENABLEDJumper removed = SL OFFMicrowave ModuleSL Front LED*SL Down LEDs**NOTE: SL features apply only to Model QT-40SLAlarm Output: NC, 19VDC - 100 mA maxTamper Output: NC, 30VDC - 500 mA maxInput Voltage: 10 to 16VDC, 12VDC nominalPowerAll wiring must be in accordancewith NEC, NFPA 70.Input
Contact AlephNoteAutomatic LED Brightness FeatureNippon Aleph Corporation-Security Products Headquarters-1-28-52, Komaoka, Tsurimi-kuYokohama-shi, Kanagawa-kenJAPAN, 230-0071Tel: +81 045-575-4290 / Fax: +81 045-580-1676E-mail: security@po.nippon-aleph.co.jpWEB: http://www.nippon-aleph.co.jpAleph America Corporation4700 Aircenter Cir, Reno, NV, 89502 USATel: 775 827 8000 / Fax: 775 827 8044E-mail: info@aleph-usa.comWEB: http://www.aleph-usa.comAleph Europe Ltd.1 Newton Close, Park Farm Industrial EstateWellingborough, Northamptonshire, NN8 6UWEnglandTel: 044 193 367 9600 / Fax: 044 193 340 1165E-mail: info@alepheurope.comWEB: http://www.alepheurope.comThe QT Series alarm LED  indicator includes an automatic brightness feature.  In order to allow for a less noticeable installation, LED brightness is reduced as the ambient light levelin the room drops.The LED can be fully disabled by removing the ALARM LED• This detector is designed to be incorporated into an  assume responsibility for theft or damage if the system  fails to operate.         Input Voltage2.4 seconds, retriggerable15 mA max. (SL model 30 mA), 11 mA quiescent (approx.)P/N 9-900-003-00  Rev.                   © 2009  Aleph America CorporationAll rights reservedAvailable accessoriesSpecificationsjumper.Note:  Dashed lines indicate typical microwave coverage.10 to 16 VDC, 12 VDC nominalDual ElementJumper selectable: PC2, PC425 - 45 secondsRed Alarm LED (Selectable On / Off)NC, solid state, 19 VDC, 100 mA, 13 ohms resistance typ.NC, dry contact, 30 VDC, 500 mA, 5 W max.7 to 8.5 ft  (2.1 to 2.6 m)14° to 131° F  (-10° to 55° C)95% humidity non-condensing4.8” H x 2.5” W x 1.7” D / 12.2cm x 6.4cm x 4.3cm3 oz / 85 gInput CurrentPyro TypePulse CountWarm-up TimeAlarm PeriodVisual IndicatorAlarm OutputTamper OutputMounting HeightOperating Temp.EnvironmentalWeightDimensionsMicrowave Freq.10.525 GHz, pulsedQT-40 & QT-40SL Main Lens:  40WAPET Wide AngleDetection PatternsSide ViewMid Range Long Range4.53.01.506.0 7.5 9.0 10.5 12.07.520 6.04.58.53.01.501.53.04.56.07.58.5m2528151050510152025280 5 10 15 20 25 30 35 40ft802.41.5 34.5 610.5 12.0000            Top ViewLookdown(Masked for PI)• 100PET  --  100 lb pet immune lens (for QT-40 & QT-40SL only)Unit does not power up.Input power polarity reversed .Apply proper input voltage.Correct wiring polarity.Alarm LED does not light.Incorrect sensor mounting height or aiming.Pulse count setting incorrect for protectionarea .Set LED jumper to “ EN ”Alter the mounting height or aim.Set pulse count jumper to suit  thedetection requirements.Alarm LED / Relay triggerswithout movement in theAnimal / rodents in protection area.Heating or a ir conditioning outlets insensor view.Pet access to furniture or room fixture inview of the detector (pet immune unit).Block access of animals / rodents.Re-aim sensor.Ensure that pets can not climb up ontofurniture / fixtures in protection area.An alarm is indicated at the LED Incorrect wiring at the alarm outputterminals.Lightning damage.Correct the wiring fault .Replace sensor.Alarm LED on constantly, no faultin protected area or wiring ..rosnesecalpeRTroubleshooting.DELDEL ABUnit continues to operate afterinput power has been discon-The wire to the “-” power input was  disconnected, the “+” is still connected.  The power is finding a return path  through the Alarm Output protection  device and alarm wiring.Disconnect wire from the “+” power  input.Maintenance• INSPECTION:  An inspection of this unit should be made periodically,• CLEANING:    Clean the external plastic parts of this unit with a soft,  • TESTING:        This unit should be tested routinely for proper operation.condition of the interior area and components. including, but not limited to all mounting, wiring, and the clean, cloth dampened with water. At a minimum, operation should be fully checked yearly. 40ft (12m) L  X  56ft (17m) WQT-60 Main Lens:  60STD0510152025303537510152025303537 0 5 10 15 20 25 30 35 40 45 50 55 600 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15 16.5 1810.597.564.531.501.534.567.5910.50 5 10 15 20 25 30 35 40 45 50 55 60080 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15 16.5 182.40mft60ft (18.3m) L  X  74ft (22.6m) WLookdownMid Range Long Rangemftftm7.5 95 10 15 20 25 30 35 40FCC/IC Statement:This equipment has been tested and found to comply withthe limits for a Class B digital device, pursuant to Part 15 andICES-003 of the FCC and Industry Canada Rules.  These limitsare designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not  installed and used inaccordance with the instructions, may cause harmful interference to radio communications.  However, there isno guarantee that interference will not occur in a particularinstallation.  If this equipment does cause harmfulinterference to radio or television reception,  which can bedetermined by turning the equipment off and on, the useris encouraged to try to correct the interference by one ormore of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and  receiver.• Connect the equipment into an outlet on a circuit   different from that to which the receiver is connected.• Consult the dealer or an experienced radio / TV  technician for help.The user should not modify or change this equipmentwithout written approval from ALEPH.Modification could void authority to use this equipment.FCC ID:  DNHQT-001-00IC:  QT00100-xxxxFCC/IC Information:Patent informationUS & international patents pendingTrouble Likely Causes Remedyprotection area .but not at the alarm output.No or low input power.Input power polarity reversed .nected.Defective unit.alarm system.  As it is part of a system, Aleph cannot

Navigation menu