Altai Technologies IX500 IX500 Indoor 2x2 802.11ac Wave 2 AP User Manual AX500 S Quick Setup Guide
Altai Technologies Limited IX500 Indoor 2x2 802.11ac Wave 2 AP AX500 S Quick Setup Guide
User Manual
Quick Setup Guide ALTAI IX500 Indoor 2x2 802.11ac Wave 2 AP _________________________________________________ Quick Setup Guide Version 1.0 Altai Technologies Ltd. All rights reserved Quick Setup Guide Introduction Thank you for purchasing the ALTAI IX500 product. This guide provides instructions to install the product and set it up as AP with minimal effort. Package Contents Ceiling Mount Base Ceiling Mount Base (15/16” T-Rail) (9/16” T-Rail) IX500 Main Unit Dry Wall Mount Kit - Anchors - Screws x2 x2 Back Cover Quick Setup Guide (For Indoor Installation) Optional Items Wall/Pole Mount Kit Mount Base Anchors (For Concrete Wall) Screws (For Concrete Wall) Cable Tie (For Pole) x1 x2 x2 x2 Back Cover (For Outdoor Installation) Altai Technologies Ltd. All rights reserved Quick Setup Guide Hardware Overview LED Indicator LED Indicator Power/Booting Off AP Powered Off Status Flashing Red AP Booting Up Solid Red AP Boot Up Finished and Ready for Service Solid Purple 1. AP Mode on but with no Client Association; OR 2.4G Radio Enabled Only 2. Station Mode on but not connected to Remote AP; OR (AP/Station/ 3. Repeater Mode on but not connected to Remote AP Repeater) Alternate Flashing Data Transmitting/Receiving Purple & Red 5G Radio Solid Yellow 1. AP Mode on but with no Client Association; OR Enabled Only 2. Station Mode on but not connected to Remote AP; OR (AP/Station/ 3. Repeater Mode on but not connected to Remote AP; OR Repeater/Bridge) 4. Bridge Mode on but not connected to Remote Peer Alternate Flashing Data Transmitting/Receiving Yellow & Red 2.4G and 5G Solid White Radios Enabled AP/Station/Repeater/Bridge Mode on but with no connection with Client/Remote AP/Remote Peer (AP/Station/ Alternate Flashing Repeater/Bridge) Purple, Yellow & Red Data Transmitting/Receiving Altai Technologies Ltd. All rights reserved Quick Setup Guide Ethernet Port, DC Power Jack and Reset Button Mount Ethernet Port Base Slot DC Power Reset Button Jack Ethernet Port: It is used to connect to power source (see the Power Options in the later section) and provides 10/100/1000 Mbps network interface for LAN connection. DC Power Jack: It is used to connect to DC power source of 12VDC/1A as another power option. Reset Button: It serves two functions: Reboot: Press and hold the Reset Button for 2-3 seconds until the red LED blinks once. Factory Reset: Press and hold the Reset Button for 5-8 seconds until the red LED blinks twice consecutively. Red LED Indicator Reboot 0s 1-2s Factory Reset 5-8s Altai Technologies Ltd. All rights reserved Quick Setup Guide Mounting Options Option 1: T-Rail Ceiling Mount (9/16” T-Rail OR 15/16” T-Rail) Select an appropriate ceiling mount base (9/16” or 15/16”) and slide the base into the slot of the AP. Insert an appropriately sized ceiling rail into one of the mount base slots first. Then turn the AP slightly so that the rail slips into another slot to lock the AP into place. Altai Technologies Ltd. All rights reserved Quick Setup Guide Option 2: Wall Mount (Concrete Wall) Determine where the AP is to be placed and mark location on the wall surface for the two mounting holes of the mount base. Use an appropriate drill bit to drill holes of 1/3” (8.1mm) diameter and 1” (26mm) deep. Screw the anchors into the holes and then insert the screws through the mount base to the anchors to attach the base to the wall. Slide the base into the slot of the AP. Altai Technologies Ltd. All rights reserved Quick Setup Guide Option 3: Pole Mount (For 1 inch to 3 inches of pole diameter) Thread the open end of the cable tie through the two slots of the mount base. Slide the base into the slot of the AP. Determine where the AP is to be placed. Tighten the cable tie to secure the base to the pole. Altai Technologies Ltd. All rights reserved Quick Setup Guide Setup Requirements and Preparation A computer with Web Browser: Google Chrome, Mozilla Firefox, or Microsoft Internet Explorer 8 (or above) Two Cat 5e/6 Ethernet cables 802af/at-compliant PoE switch (54Vdc/0.6A) AltaiCare account (Optional) for cloud AP management and user service Power Options and Cable Connection Instructions IX500 AP Ethernet Cable (PoE + Data) Ethernet Cable 802.3af/802.at – Compliant (Data) PoE Switch 1. Connect the IX500 Ethernet port to an 802.3af/802.at-compliant PoE switch with an Ethernet Cable. 2. Connect a computer to the switch. 3. Make sure the LED indicator turns into a solid light for AP configuration. Altai Technologies Ltd. All rights reserved Quick Setup Guide 1. Change TCP/IP Setting on Your Computer For Windows 7 users, 1. Go to Control Panel, click Network and Sharing Center and then choose the adapter that you want to connect to IX500 unit. In this example, adapter “Local Area Connection” is in connection with IX500-S. Click it and then click Properties. 2. Under the Networking tab, click Internet Protocol Version 4 (TCP/IPv4) in the list box “This connection uses the following items”, and then click Properties. 3. Type in the following IP address and Subnet mask: IP address: 192.168.1.2 Subnet mask: 255.255.255.0 4. Click OK to close the Internet Protocol Version 4 (TCP/IP) Properties dialog box and click OK again to close the Local Area Connection Properties dialog box. Altai Technologies Ltd. All rights reserved Quick Setup Guide 2. Access to Web Interface 1. Open a web browser. Type 192.168.1.222 in the address bar and then hit Enter. 2. Login page will come up and you are required to enter username and password. By default, the credentials are: Username: admin Password: admin 3. Click Login. 10 Altai Technologies Ltd. All rights reserved Quick Setup Guide 3. Configure AP Mode (2.4G/5G) Network Scenario ISP Modem Gateway/Router IX500 (AP Mode) Internet 2.4G + 5G Modem Ethernet Ethernet Cable Cable Cable Coverage Go to Configuration > Wireless > Radio0(2.4G)/Radio1(5G) > General. Below screenshots show an example for 2.4G radio configuration only. Same procedures can be applied to 5G radio configuration. 1. Make sure the box of Enable Radio is checked. Select AP mode for the field of Radio Mode. Then click Submit. 2. Click WLAN and click More… in Detail of WLAN 0 to go to another page for SSID and security configuration. 11 Altai Technologies Ltd. All rights reserved Quick Setup Guide 3. Make sure WLAN is enabled by checking the box. Type in SSID to name the wireless network you want to broadcast and then click Submit. 4. Click the tab WLAN Security. Select WPA2-PSK from the drop down menu of Authentication Mode and select AES for Cipher Mode. Type in a password within 8~64 characters or numbers in Pass Phrase and click Submit. 5. Click Save & Apply at the top right corner to have all changes take effect. 6. Hook up the IX500 as shown in Network Scenario. The SSID should now be broadcast from IX500 and can be seen in the computer for wireless connection. 12 Altai Technologies Ltd. All rights reserved Quick Setup Guide 4. Connect with Cloud-Based Controller – AltaiCare Network Scenario: ISP Modem IX500_1 (AP) Local Gateway/ Router IX500_2 (AP) 1. You can manage your IX500 and set up hotspot service for the subscribers with AltaiCare, which is a cloud-based system. 2. Go to Configuration > Network > General. Select Switch Mode for Network Setting and make sure the IX500 can reach Internet and communicate with AltaiCare by inputting valid IP settings either via DHCP or with Static IP configuration. Google Public DNS Server can be considered, e.g. 8.8.8.8 or 8.8.4.4 if you are not sure about the ISP DNS’s Server IP. 13 Altai Technologies Ltd. All rights reserved Quick Setup Guide 3. Click Remote Mgmt and check the box of Enable Remote Management. Select AltaiCare as Management Type and Cloud as Connection Type. 4. Select Full Management if the device is running in AP Mode. For Station Mode, Bridge Mode and Repeater Mode, select Monitor Mode instead. 5. Click Submit and then Save & Apply at the top right corner to make all the changes take effect. 6. Follow AltaiCare Quick Start Guide and register the IX500 in the system for AP management and user service and admission control. 7. IX500 will appear as online in AltaiCare AP list if the connection is successful. 14 Altai Technologies Ltd. All rights reserved Quick Setup Guide Federal Communication Commission Interference Statement (FCC) – USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. European Conformity (CE) – EU This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. 15 Altai Technologies Ltd. All rights reserved Wong's International USA Corp. 2905 Stender Way, Ste. 52, Santa Clara, CA 95054, USA Contact person: Mr. Lawrence Tan Email: lawrence.tan@wihl.us.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Taylor Wan Create Date : 2018:08:15 14:27:32+08:00 Modify Date : 2018:10:05 17:02:58+08:00 Has XFA : No Language : zh-TW Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Creator : Taylor Wan Title : AX500-S Quick Setup Guide Creator Tool : Microsoft® Word 2010 Metadata Date : 2018:10:05 17:02:58+08:00 Producer : Microsoft® Word 2010 Document ID : uuid:a9e73f79-4c51-49df-a576-139f3933750d Instance ID : uuid:baea7611-8145-40bf-bec2-ae2f7bb6b714 Page Count : 16EXIF Metadata provided by EXIF.tools