Altinex Da1506Rt Users Manual 400 0016 004
DA1506RT to the manual b87f9c2b-943f-4b4a-a09b-f26c6d6dc287
2015-02-05
: Altinex Altinex-Da1506Rt-Users-Manual-507007 altinex-da1506rt-users-manual-507007 altinex pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER: 400-0016-004 DA1506RT 2-IN, 6-OUT VGA DISTRIBUTION AMPLIFIER USER’S GUIDE DISTRIBUTION AMPLIFIERS TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS................ 2 GENERAL..........................................................2 RACK-MOUNTING SAFETY GUIDELINES........2 HANDLING ........................................................2 CLEANING.........................................................2 FCC NOTICE .....................................................2 ABOUT YOUR DA1506RT ....................................... 3 TECHNICAL SPECIFICATIONS.............................. 3 PRODUCT DESCRIPTION ...................................... 4 APPLICATION DIAGRAMS...................................... 4 DIAGRAM 1: TYPICAL SETUP ..........................4 DIAGRAM 2: INTERNAL VIEW ..........................5 DIAGRAM 3: CONNECTOR PINOUTS ..............6 INSTALLING YOUR DA1506RT............................. 7 OPERATION ............................................................... 7 TROUBLESHOOTING GUIDE................................. 7 ALTINEX POLICIES .................................................. 7 LIMITED WARRANTY/RETURN POLICIES .......7 CONTACT INFORMATION ................................7 400-0016-004 1 DISTRIBUTION AMPLIFIERS PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your DA1506RT Distribution Amplifier. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your DA1506RT and to prevent fire and shock hazards. Please read them carefully and heed all warnings. Qualified ALTINEX service personnel or its authorized representatives must perform all service. The maximum operating ambient temperature for this unit is 35°C. • Distribute units evenly inside the rack. Hazardous conditions may be created by an uneven weight distribution. • Connect the unit to a properly rated circuit. • Reliable grounding should be maintained. • If the DA1506RT is not used for an extended period, disconnect the power cord. • Unplug the DA1506RT before cleaning. • Clean only with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean. 1.4 FCC NOTICE 1.2. RACK-MOUNTING SAFETY GUIDELINES • Do not pull any cables that are attached to the DA1506RT. 1.4 CLEANING 1.1 GENERAL • • • • 1.3 HANDLING • For best results, place the DA1506RT on a flat, level surface in a dry area away from dust and moisture. • To prevent fire or shock, do not expose this unit to water or moisture. Do not place the DA1506RT in direct sunlight, near heaters or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components. • Handle the DA1506RT carefully. Dropping or jarring can damage internal components. • Do not place heavy objects on top of the DA1506RT. If the DA1506RT is to be mounted to a table or wall, use only ALTINEX-made mounting accessories. • To turn off the main power, be sure to remove the power cord. The power outlet should be installed as near to the equipment as possible, and should be easily accessible. 400-0016-004 • 2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment. DISTRIBUTION AMPLIFIERS ABOUT YOUR DA1506RT 2 MECHANICAL DA1506RT 2-In, 6-Out Distribution Amplifier (DA) Material 1.75 in (44mm) Width (inches) 8.50 in (216mm) Depth (inches) 4.50 in (114mm) 2.0 lb (0.91 kg) T° Operating 10°C-35°C T° Maximum Humidity 50°C 90% non-condensing 40,000 hrs Table 2. DA1506RT Mechanical ELECTRICAL DA1506RT Input Video Signal Analog Signal Impedance 1.5 Vp-p max 75 ohms Input Sync Signal Horiz/Vert/Composite Sync Sync on Green Impedance TTL(+/-) -0.3V 10 kohms Output Video Signals Analog Signal Impedance 0 dB +/-0.5 dB 75 ohm Output Sync Signal 3 Horiz/Vert/Composite Sync Specifications are subject to change. See www.altinex.com for up-to-date information. Sync on Green Impedance DA1506RT Coupling TTL(+/-) -0.3 V 75 ohms DC Power 15-pin HD female (2) 15-pin HD female (6) VGA through UXGA, RGBHV, RGBS, RGsB, and RsGsBs External adapter (included) Total Power Table 3. DA1506RT Electrical Table 1. DA1506RT General 400-0016-004 Height (inches) MTBF (calculations) Though primarily designed for use with displays using 15-pin HD (VGA-type) connectors, the DA1506RT can pass RGBHV, RGBS, and RGsB format signals using adapter cables. The DA1506RT is great for desktop use, but can also be rack-mounted using optional ALTINEX hardware. Compatibility Gray Weight (pounds) The rear panel of the DA1506RT has 1 computer input and 6 outputs, while the front panel has a single input. If both the front and rear inputs have valid video signals, the image from the front panel will be displayed on the 6 outputs. The rear input can be permanently connected for normal operation and the front panel input can be saved for special applications. For example, a desktop PC is permanently connected to the rear panel along with the display devices. The image from a second source, like a laptop, may be connected to the front panel and temporarily override the desktop’s image. The DA1506DT will automatically switch to the front panel’s image. FEATURES/ DESCRIPTION GENERAL Input Connectors Output Connectors 0.1” Al Finish The DA1506RT is a 2-In, 6-Out VGA through UXGA distribution amplifier (DA). It is designed to connect 1 of 2 computer video sources to as many as 6 monitors, displays, and projectors. TECHNICAL SPECIFICATIONS DA1506RT 3 9 VDC 500 mA 2.5W max. DISTRIBUTION AMPLIFIERS PRODUCT DESCRIPTION 4 FRONT VIEW INPUT1 INPUT2 REAR VIEW OUTPUTS 1-6 POWER APPLICATION DIAGRAMS 5 DIAGRAM 1: TYPICAL SETUP DA1506RT 400-0016-004 4 DISTRIBUTION AMPLIFIERS DIAGRAM 2: INTERNAL VIEW 2-IN 6-OUT VGA-XGA DA OUT 1 PLUG AND PLAY AUTO SWITCH OUT 2 FRONT OUT 3 BACK OUT 4 15-PIN HD OUT 5 PLUG AND PLAY OUT 6 SIGNAL DETECT POWER 9V, 0.5A 400-0016-004 POWER PS 5 15-PIN HD DISTRIBUTION AMPLIFIERS DIAGRAM 3: CONNECTOR PINOUTS INPUT CONNECTORS Pin No. OUTPUT CONNECTORS PIN ASSIGNMENTS Pin No. PIN ASSIGNMENTS 1 Red 1 Red 2 Green 2 Green 3 Blue 3 Blue 4 Ground 4 No Connection 5 Ground 5 Ground 6 Ground 6 Ground 7 Ground 7 Ground 8 Ground 8 Ground 9 VESA +5V IN 9 +5V 10 Ground 10 Ground 11 Ground 11 No Connection 12 VESA SDA 12 No Connection 13 Horizontal Sync 13 Horizontal Sync 14 Vertical Sync 14 Vertical Sync 15 VESA SCL 15 No Connection Table 4. The DA1506RT Input Pins 400-0016-004 Table 5. The DA1506RT Output Pins 6 DISTRIBUTION AMPLIFIERS INSTALLING YOUR DA1506RT 6 TROUBLESHOOTING GUIDE Step 1. Plug the power adapter into an AC receptacle. We have carefully tested and found no problems in the supplied DA1506RT; however, we would like to offer suggestions for the following: Step 2. Connect the power to the unit. The power indicator LEDs on the front and back panels will turn on and red. This indicates that the unit is operational. Step 3. Connect a VGA-type cable from a computer to Input 2 on the amplifier’s rear panel. The LEDs will remain red, but the images will be present on the output connectors. Step 4. Connect a VGA-type cable from another PC or laptop to Input 1 on the amplifier’s front panel. If there is a signal present on Input 1, then the LEDs will turn green indicating that Input 1’s image is the image present on the output connectors. Step 5. Connect the output connectors of the amplifier to your display devices: monitors, projectors, LCDs, etc. • Please make sure that the input amplitude of analog signal is less than 1.5 Vp-p. • Please use the ALTINEX-supplied external adapter (9V, 500mA). • Please make sure that proper quality of cables is used. We recommend ALTINEX-made cables for best results. • If a problem arises after continuous usage at higher voltage, higher temperature, higher humidity, or at other extreme environmental conditions, please make the necessary adjustments for the DA1506RT to function safely and properly. ALTINEX POLICIES Please see the ALTINEX website at www.altinex.com for details on warranty and return policies. 9.2 CONTACT INFORMATION ALTINEX, Inc. 592 Apollo Street 7 Brea, CA 92821 USA There are no adjustments necessary to operate the unit. The DA1506RT will operate successfully as long as cables are attached properly and other technical specifications are followed. TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com 400-0016-004 9 9.1 LIMITED WARRANTY/RETURN POLICIES Step 6. If the image is less than perfect, check all of the connections. Poor quality cables may often degrade the performance of the product. Make sure that the cables used are coaxial cables and that all pins are in good condition. OPERATION 8 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 8 Page Mode : UseNone Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:4e55ab91-096b-4dc5-8252-e8f138dac6c6 Creation Date--Text : 20/10/2006 9:27:34 Producer : Amyuni Document Converter Version : Version 2.11c - Licensed to Document Automation Developers Modify Date : 2006:11:01 16:34:12-08:00 Metadata Date : 2006:11:01 16:34:12-08:00 Document ID : uuid:0e53098e-a557-4a32-93ed-5ade5e2aacd7 Format : application/pdf Title : 400-0016-004.doc Create Date : 20/10/2006 9:27:34EXIF Metadata provided by EXIF.tools