Altinex Da1506Rt Users Manual 400 0016 004

DA1506RT to the manual b87f9c2b-943f-4b4a-a09b-f26c6d6dc287

2015-02-05

: Altinex Altinex-Da1506Rt-Users-Manual-507007 altinex-da1506rt-users-manual-507007 altinex pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadAltinex Altinex-Da1506Rt-Users-Manual- 400-0016-004  Altinex-da1506rt-users-manual
Open PDF In BrowserView PDF
DISTRIBUTION AMPLIFIERS

MANUAL PART NUMBER: 400-0016-004

DA1506RT
2-IN, 6-OUT VGA
DISTRIBUTION AMPLIFIER
USER’S GUIDE

DISTRIBUTION AMPLIFIERS
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS................ 2
GENERAL..........................................................2
RACK-MOUNTING SAFETY GUIDELINES........2
HANDLING ........................................................2
CLEANING.........................................................2
FCC NOTICE .....................................................2
ABOUT YOUR DA1506RT ....................................... 3
TECHNICAL SPECIFICATIONS.............................. 3
PRODUCT DESCRIPTION ...................................... 4
APPLICATION DIAGRAMS...................................... 4
DIAGRAM 1: TYPICAL SETUP ..........................4
DIAGRAM 2: INTERNAL VIEW ..........................5
DIAGRAM 3: CONNECTOR PINOUTS ..............6
INSTALLING YOUR DA1506RT............................. 7
OPERATION ............................................................... 7
TROUBLESHOOTING GUIDE................................. 7
ALTINEX POLICIES .................................................. 7
LIMITED WARRANTY/RETURN POLICIES .......7
CONTACT INFORMATION ................................7

400-0016-004

1

DISTRIBUTION AMPLIFIERS
PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your
DA1506RT Distribution Amplifier. Keep this manual
handy for future reference. These safety
instructions are to ensure the long life of your
DA1506RT and to prevent fire and shock hazards.
Please read them carefully and heed all warnings.

Qualified ALTINEX service personnel or its
authorized representatives must perform all
service.

The maximum operating ambient temperature
for this unit is 35°C.

•

Distribute units evenly inside the rack.
Hazardous conditions may be created by an
uneven weight distribution.

•

Connect the unit to a properly rated circuit.

•

Reliable grounding should be maintained.

•

If the DA1506RT is not used for an extended
period, disconnect the power cord.

•

Unplug the DA1506RT before cleaning.

•

Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean
the unit. Do not open the unit to clean.

1.4 FCC NOTICE

1.2. RACK-MOUNTING SAFETY GUIDELINES
•

Do not pull any cables that are attached to the
DA1506RT.

1.4 CLEANING

1.1 GENERAL
•

•

•

•

1.3 HANDLING
•

For best results, place the DA1506RT on a flat,
level surface in a dry area away from dust and
moisture.

•

To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the
DA1506RT in direct sunlight, near heaters or
heat-radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam can
harm internal components.

•

Handle the DA1506RT carefully. Dropping or
jarring can damage internal components.

•

Do not place heavy objects on top of the
DA1506RT. If the DA1506RT is to be mounted
to a table or wall, use only ALTINEX-made
mounting accessories.

•

To turn off the main power, be sure to remove
the power cord. The power outlet should be
installed as near to the equipment as possible,
and should be easily accessible.

400-0016-004

•

2

This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.

DISTRIBUTION AMPLIFIERS
ABOUT YOUR DA1506RT

2

MECHANICAL

DA1506RT
2-In, 6-Out Distribution Amplifier (DA)

Material

1.75 in (44mm)

Width (inches)

8.50 in (216mm)

Depth (inches)

4.50 in (114mm)
2.0 lb (0.91 kg)

T° Operating

10°C-35°C

T° Maximum
Humidity

50°C
90% non-condensing
40,000 hrs

Table 2. DA1506RT Mechanical
ELECTRICAL

DA1506RT

Input Video Signal
Analog Signal
Impedance

1.5 Vp-p max
75 ohms

Input Sync Signal
Horiz/Vert/Composite Sync
Sync on Green
Impedance

TTL(+/-)
-0.3V
10 kohms

Output Video Signals
Analog Signal
Impedance

0 dB +/-0.5 dB
75 ohm

Output Sync Signal

3

Horiz/Vert/Composite Sync

Specifications are subject to change.
See www.altinex.com for up-to-date information.

Sync on Green
Impedance

DA1506RT

Coupling

TTL(+/-)
-0.3 V
75 ohms
DC

Power
15-pin HD female (2)
15-pin HD female (6)
VGA through UXGA,
RGBHV, RGBS,
RGsB, and RsGsBs

External adapter (included)
Total Power
Table 3. DA1506RT Electrical

Table 1. DA1506RT General

400-0016-004

Height (inches)

MTBF (calculations)

Though primarily designed for use with displays
using 15-pin HD (VGA-type) connectors, the
DA1506RT can pass RGBHV, RGBS, and RGsB
format signals using adapter cables. The
DA1506RT is great for desktop use, but can also
be rack-mounted using optional ALTINEX
hardware.

Compatibility

Gray

Weight (pounds)

The rear panel of the DA1506RT has 1 computer
input and 6 outputs, while the front panel has a
single input. If both the front and rear inputs have
valid video signals, the image from the front panel
will be displayed on the 6 outputs. The rear input
can be permanently connected for normal operation
and the front panel input can be saved for special
applications. For example, a desktop PC is
permanently connected to the rear panel along with
the display devices. The image from a second
source, like a laptop, may be connected to the front
panel and temporarily override the desktop’s
image. The DA1506DT will automatically switch to
the front panel’s image.

FEATURES/
DESCRIPTION
GENERAL
Input Connectors
Output Connectors

0.1” Al

Finish

The DA1506RT is a 2-In, 6-Out VGA through
UXGA distribution amplifier (DA). It is designed to
connect 1 of 2 computer video sources to as many
as 6 monitors, displays, and projectors.

TECHNICAL SPECIFICATIONS

DA1506RT

3

9 VDC 500 mA
2.5W max.

DISTRIBUTION AMPLIFIERS
PRODUCT DESCRIPTION

4

FRONT VIEW

INPUT1

INPUT2
REAR VIEW

OUTPUTS 1-6
POWER

APPLICATION DIAGRAMS

5

DIAGRAM 1: TYPICAL SETUP

DA1506RT

400-0016-004

4

DISTRIBUTION AMPLIFIERS
DIAGRAM 2: INTERNAL VIEW

2-IN 6-OUT VGA-XGA DA

OUT 1
PLUG AND PLAY

AUTO SWITCH

OUT 2

FRONT

OUT 3

BACK

OUT 4

15-PIN HD

OUT 5
PLUG AND PLAY

OUT 6
SIGNAL
DETECT

POWER
9V, 0.5A

400-0016-004

POWER

PS

5

15-PIN HD

DISTRIBUTION AMPLIFIERS
DIAGRAM 3: CONNECTOR PINOUTS

INPUT CONNECTORS
Pin No.

OUTPUT CONNECTORS

PIN ASSIGNMENTS

Pin No.

PIN ASSIGNMENTS

1

Red

1

Red

2

Green

2

Green

3

Blue

3

Blue

4

Ground

4

No Connection

5

Ground

5

Ground

6

Ground

6

Ground

7

Ground

7

Ground

8

Ground

8

Ground

9

VESA +5V IN

9

+5V

10

Ground

10

Ground

11

Ground

11

No Connection

12

VESA SDA

12

No Connection

13

Horizontal Sync

13

Horizontal Sync

14

Vertical Sync

14

Vertical Sync

15

VESA SCL

15

No Connection

Table 4. The DA1506RT Input Pins

400-0016-004

Table 5. The DA1506RT Output Pins

6

DISTRIBUTION AMPLIFIERS
INSTALLING YOUR DA1506RT

6

TROUBLESHOOTING GUIDE

Step 1. Plug the power adapter into an AC
receptacle.

We have carefully tested and found no problems in
the supplied DA1506RT; however, we would like to
offer suggestions for the following:

Step 2. Connect the power to the unit. The power
indicator LEDs on the front and back
panels will turn on and red. This indicates
that the unit is operational.
Step 3. Connect a VGA-type cable from a
computer to Input 2 on the amplifier’s rear
panel. The LEDs will remain red, but the
images will be present on the output
connectors.
Step 4. Connect a VGA-type cable from another
PC or laptop to Input 1 on the amplifier’s
front panel. If there is a signal present on
Input 1, then the LEDs will turn green
indicating that Input 1’s image is the
image present on the output connectors.
Step 5. Connect the output connectors of the
amplifier to your display devices:
monitors, projectors, LCDs, etc.

•

Please make sure that the input amplitude of
analog signal is less than 1.5 Vp-p.

•

Please use the ALTINEX-supplied external
adapter (9V, 500mA).

•

Please make sure that proper quality of cables is
used. We recommend ALTINEX-made cables
for best results.

•

If a problem arises after continuous usage at
higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please make the necessary
adjustments for the DA1506RT to function safely
and properly.

ALTINEX POLICIES

Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street

7

Brea, CA 92821 USA

There are no adjustments necessary to operate the
unit. The DA1506RT will operate successfully as
long as cables are attached properly and other
technical specifications are followed.

TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: solutions@altinex.com

400-0016-004

9

9.1 LIMITED WARRANTY/RETURN POLICIES

Step 6. If the image is less than perfect, check all
of the connections. Poor quality cables
may often degrade the performance of the
product. Make sure that the cables used
are coaxial cables and that all pins are in
good condition.

OPERATION

8

7



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Page Count                      : 8
Page Mode                       : UseNone
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4e55ab91-096b-4dc5-8252-e8f138dac6c6
Creation Date--Text             : 20/10/2006 9:27:34
Producer                        : Amyuni Document Converter
Version                         : Version 2.11c - Licensed to Document Automation Developers
Modify Date                     : 2006:11:01 16:34:12-08:00
Metadata Date                   : 2006:11:01 16:34:12-08:00
Document ID                     : uuid:0e53098e-a557-4a32-93ed-5ade5e2aacd7
Format                          : application/pdf
Title                           : 400-0016-004.doc
Create Date                     : 20/10/2006 9:27:34
EXIF Metadata provided by EXIF.tools

Navigation menu