Altinex Da1506Rt Users Manual 400 0016 004

DA1506RT to the manual b87f9c2b-943f-4b4a-a09b-f26c6d6dc287

2015-02-05

: Altinex Altinex-Da1506Rt-Users-Manual-507007 altinex-da1506rt-users-manual-507007 altinex pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DISTRIBUTION AMPLIFIERS
MANUAL PART NUMBER: 400-0016-004
2-IN, 6-OUT VGA
DISTRIBUTION AMPLIFIER
USER’S GUIDE
DA1506RT
DISTRIBUTION AMPLIFIERS
400-0016-0041
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS................ 2
GENERAL..........................................................2
RACK-MOUNTING SAFETY GUIDELINES........2
HANDLING ........................................................2
CLEANING.........................................................2
FCC NOTICE .....................................................2
ABOUT YOUR DA1506RT ....................................... 3
TECHNICAL SPECIFICATIONS.............................. 3
PRODUCT DESCRIPTION ...................................... 4
APPLICATION DIAGRAMS...................................... 4
DIAGRAM 1: TYPICAL SETUP ..........................4
DIAGRAM 2: INTERNAL VIEW..........................5
DIAGRAM 3: CONNECTOR PINOUTS ..............6
INSTALLING YOUR DA1506RT............................. 7
OPERATION............................................................... 7
TROUBLESHOOTING GUIDE................................. 7
ALTINEX POLICIES .................................................. 7
LIMITED WARRANTY/RETURN POLICIES.......7
CONTACT INFORMATION ................................7
DISTRIBUTION AMPLIFIERS
400-0016-0042
PRECAUTIONS / SAFETY WARNINGS 1
Please read this manual carefully before using your
DA1506RT Distribution Amplifier. Keep this manual
handy for future reference. These safety
instructions are to ensure the long life of your
DA1506RT and to prevent fire and shock hazards.
Please read them carefully and heed all warnings.
1.1 GENERAL
Qualified ALTINEX service personnel or its
authorized representatives must perform all
service.
1.2. RACK-MOUNTING SAFETY GUIDELINES
The maximum operating ambient temperature
for this unit is 35°C.
Distribute units evenly inside the rack.
Hazardous conditions may be created by an
uneven weight distribution.
Connect the unit to a properly rated circuit.
Reliable grounding should be maintained.
1.3 HANDLING
For best results, place the DA1506RT on a flat,
level surface in a dry area away from dust and
moisture.
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the
DA1506RT in direct sunlight, near heaters or
heat-radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam can
harm internal components.
Handle the DA1506RT carefully. Dropping or
jarring can damage internal components.
Do not place heavy objects on top of the
DA1506RT. If the DA1506RT is to be mounted
to a table or wall, use only ALTINEX-made
mounting accessories.
To turn off the main power, be sure to remove
the power cord. The power outlet should be
installed as near to the equipment as possible,
and should be easily accessible.
Do not pull any cablesthat are attached to the
DA1506RT.
If the DA1506RT is not used for an extended
period, disconnect the power cord.
1.4 CLEANING
Unplug the DA1506RT before cleaning.
Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean
the unit. Do not open the unit to clean.
1.4 FCC NOTICE
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.
DISTRIBUTION AMPLIFIERS
400-0016-0043
ABOUT YOUR DA1506RT 2
DA1506RT
2-In, 6-Out Distribution Amplifier (DA)
The DA1506RT is a 2-In, 6-Out VGA through
UXGA distribution amplifier (DA). It is designed to
connect 1of 2computer video sources to as many
as 6 monitors, displays, and projectors.
The rear panel of the DA1506RT has 1 computer
input and 6 outputs, while the front panel has a
single input. If both the front and rear inputs have
valid video signals, the image from the front panel
will be displayed on the 6 outputs. Therear input
can be permanently connected for normal operation
and the front panel input can be saved for special
applications. For example, a desktop PC is
permanently connected to the rear panel along with
the display devices. The image from a second
source, like a laptop, may be connected to the front
panel and temporarily override the desktop’s
image. The DA1506DT will automatically switch to
the front panel’s image.
Though primarily designed for use with displays
using 15-pin HD (VGA-type) connectors, the
DA1506RT can pass RGBHV, RGBS, and RGsB
format signals using adapter cables. The
DA1506RT is great for desktop use, but can also
be rack-mounted using optional ALTINEX
hardware.
TECHNICAL SPECIFICATIONS 3
Specifications are subject to change.
See www.altinex.com for up-to-date information.
FEATURES/
DESCRIPTION DA1506RT
GENERAL
Input Connectors15-pin HD female (2)
Output Connectors 15-pin HD female (6)
Compatibility VGA through UXGA,
RGBHV, RGBS,
RGsB, and RsGsBs
Table 1. DA1506RT General
MECHANICALDA1506RT
Material 0.1” Al
Finish Gray
Height (inches) 1.75 in (44mm)
Width (inches) 8.50 in (216mm)
Depth (inches) 4.50 in (114mm)
Weight (pounds) 2.0 lb (0.91 kg)
T°Operating 10°C-35°C
T°Maximum 50°C
Humidity 90%non-condensing
MTBF (calculations) 40,000 hrs
Table 2. DA1506RT Mechanical
ELECTRICAL DA1506RT
Input Video Signal
Analog Signal 1.5 Vp-p max
Impedance 75 ohms
Input Sync Signal
Horiz/Vert/Composite Sync TTL(+/-)
Sync on Green -0.3V
Impedance 10 kohms
Output Video Signals
Analog Signal 0 dB +/-0.5 dB
Impedance 75 ohm
Output Sync Signal
Horiz/Vert/Composite Sync TTL(+/-)
Sync on Green -0.3 V
Impedance 75 ohms
Coupling DC
Power
External adapter (included) 9VDC 500 mA
Total Power 2.5W max.
Table 3. DA1506RT Electrical
DISTRIBUTION AMPLIFIERS
400-0016-0044
PRODUCT DESCRIPTION 4
APPLICATION DIAGRAMS 5
DIAGRAM 1: TYPICAL SETUP
INPUT2
POWER
INPUT1
OUTPUTS 1-6
REAR VIEW
FRONT VIEW
DA1506RT
DISTRIBUTION AMPLIFIERS
400-0016-0045
DIAGRAM 2: INTERNAL VIEW
15-PIN HD
PS
POWER
DETECT
SIGNAL
PLUG AND PLAY
PLUG AND PLAY
BACK
FRONT
AUTO SWITCH
15-PIN HD
OUT 4
OUT 6
OUT 5
OUT 3
OUT 2
OUT 1
2-IN 6-OUT VGA-XGA DA
POWER
9V, 0.5A
DISTRIBUTION AMPLIFIERS
400-0016-0046
DIAGRAM 3: CONNECTOR PINOUTS
INPUT CONNECTORS
Pin No. PIN ASSIGNMENTS
1Red
2Green
3Blue
4Ground
5Ground
6Ground
7Ground
8Ground
9VESA +5V IN
10 Ground
11 Ground
12 VESA SDA
13 Horizontal Sync
14 Vertical Sync
15 VESA SCL
Table 4. The DA1506RT Input Pins
OUTPUT CONNECTORS
Pin No. PIN ASSIGNMENTS
1Red
2Green
3Blue
4No Connection
5Ground
6Ground
7Ground
8Ground
9+5V
10 Ground
11 No Connection
12 No Connection
13 Horizontal Sync
14 Vertical Sync
15 No Connection
Table 5. The DA1506RT Output Pins
DISTRIBUTION AMPLIFIERS
400-0016-0047
INSTALLING YOUR DA1506RT 6
Step 1. Plug the power adapter into an AC
receptacle.
Step 2. Connect the power to the unit. The power
indicator LEDson the front and back
panelswill turn on and red. This indicates
that the unit is operational.
Step 3. Connect a VGA-type cable from a
computer to Input 2on the amplifier’s rear
panel. The LEDs will remain red, but the
images will be present on the output
connectors.
Step 4. Connect a VGA-type cable from another
PC or laptop to Input 1on the amplifier’s
front panel. If there is a signal present on
Input 1, then the LEDs will turn green
indicating that Input 1’s image is the
image present on the output connectors.
Step 5. Connect the output connectors of the
amplifier to your display devices:
monitors, projectors, LCDs, etc.
Step 6. If the image is less than perfect, check all
of the connections. Poor quality cables
may often degrade the performance of the
product. Make sure that the cables used
are coaxial cables and that all pins are in
good condition.
OPERATION 7
There are no adjustments necessary to operate the
unit. The DA1506RT will operate successfully as
long as cables are attached properly and other
technical specifications are followed.
TROUBLESHOOTING GUIDE 8
We have carefully tested and found no problems in
the supplied DA1506RT; however, we would like to
offer suggestions for the following:
Please make sure that the input amplitude of
analog signal is less than 1.5 Vp-p.
Please use the ALTINEX-supplied external
adapter (9V, 500mA).
Please make sure that proper quality of cables is
used. We recommend ALTINEX-made cables
for best results.
If a problem arises after continuous usage at
higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please make the necessary
adjustments for the DA1506RT to function safely
and properly.
ALTINEX POLICIES 9
9.1 LIMITED WARRANTY/RETURN POLICIES
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street
Brea, CA 92821 USA
TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: solutions@altinex.com

Navigation menu