Alvarion Technologies BMAX-BA36 BreezeMax 3.6 Broadband Wireless Access System User Manual BreezeMAX TDD BST System Manual
Alvarion Technologies Ltd. BreezeMax 3.6 Broadband Wireless Access System BreezeMAX TDD BST System Manual
user manual
BreezeMAX™ TDD Modular Base Station System Manual SW Version 4.5 January 2008 P/N Document History Document History Topic Description Version/Date Issued First Release New Product Manual SW Version 4.0.1, October 2006 Output power range of Control range of new 2.x GHz SW Version 4.0.2 2.x GHz AU-ODUs. Section 1.5.1, AU-ODU units (HC08 version December 2006 Section 2.1, Section 4.8.4.4 137) is 30 - 36 dBm. If diversity is used, all ODUs connected to the same AU-IDU must use the same HC08 version. Available AU-ODU units Added SW Version 4.0.2 Section 1.5.1, Section 1.5.10.1 AU-ODU-HP-2.3-Extended WCS December 2006 Optimal Uplink RSSI Updated range and default SW Version 4.0.2 Section 4.5.2.4.2 value. In version 4.0.2 this December 2006 Section 2.1.1.1 parameter is not updated in run-time (reset required) DL-UL Ratio Updated combinations of SW Version 4.0.2 Section 4.5.2.6.2, Sub-Channelizations, December 2006 Bandwidth, AU Service Type and Maximum Cell Radius for which certain DL-UL Ratios are not available Rate BPSK 3/4 removed Rate BPSK 3/4 is not available SW Version 4.0.2 Section 1.5.1, Section 4.9.5.3.4, in TDD systems (according to December 2006 Section 4.10.7.3.4 standard) ARQ Enable/Disable In the current release ARQ SW Version 4.0.2 Section 4.9.5.3.1.2 should not be enabled December 2006 AU Service Type New parameter SW Version 4.0.2 Section 4.9.5.3.5.2 SU MAC Parameters December 2006 Changed functionality Section 4.10.7.3.2 SU Phy Parameters Section 4.10.7.3.3 ii SW Version 4.0.2 December 2006 Changed functionality SW Version 4.0.2 December 2006 BreezeMAX Modular Base Station System Manual Document History Topic Description Version/Date Issued Best BST/AU Parameters Updated explanations. Added SW Version 4.0.2 Section 4.10.7.3.10 Best BST/AU ID and Best December 2006 BST/AU ID Mask (replace Base Station ID and Base Station ID Mask in the SU MAC menu that starting from this version will not be applicable for units operating in TDD/Advanced Si mode). Radio Parameters Updated explanations. Added SW Version 4.0.2 Section 4.10.7.3.11 Bandwidth (replace the December 2006 Bandwidth parameter in the SU Phy menu that starting from this version will not be applicable for units operating in TDD/Advanced Si mode). NPU Parameters Summary Updated to reflect all changes Section 4.12 SW Version 4.0.2 December 2006 High-Power PIU Added new PIU type SW Version 4.1 Section 1.2.6, Section 1.2.7, (High-Power PIU) April 2007 Power Cable for High-Power PIU Added instruction for cable for SW Version 4.1 Section 2.2.5.2 new PIU type April 2007 3.x GHz Antennas BS ANT 90V/3.3-3.7 removed SW Version 4.1 Section 1.5.3, Section 1.5.10.5 from list of optional antennas April 2007 Maximum number of Data Updated to 32 per direction SW Version 4.1 Section 1.5.10.2, Section 1.5.10.3, Section 2.2.3, Section 2.2.5, Section 4.5.1 April 2007 Connections per SU Section 1.5.9 ODU Operating Temperature Updated specifications of SW Version 4.1 Section 1.5.7 Operating Temperature: April 2007 AU-ODU-HP-2.3-WCS: -52°C to 55°C All other ODUs: -40°C to 55°C BreezeMAX Modular Base Station System Manual iii Document History Topic Description Version/Date Issued 3.3 GHz band New frequency band SW Version 4.1 Section 1.1, Section 1.5.1, April 2007 Section 4.8.5 IP address configuration Updated limitations SW Version 4.1 April 2007 Section 4.3, Section 4.5.4.2.2.1, Section 4.5.4.3.2.1, Section 4.6.3.1.1, Section 4.6.3.1.3, Section 4.6.3.2.1, Section 4.6.3.2.3, Section 4.6.3.3.3.1 Switching Mode New feature (IP CS Switching SW Version 4.1 Section 1.1, Section 4.5.2.3, Mode) April 2007 Optimal Uplink RSSI Reset is not required. Actual SW Version 4.1 Section 4.5.2.4.2, Section 4.9.5.1 range in the AU is -80 to -74 April 2007 Section 4.5.4, Section 4.6.3.5, Section 4.9.3.2, Section 4.9.5.1, Section 4.9.5.3.5.1, Section 4.10.1, Section 4.10.4.2, Section 4.10.7.1, Section 4.10.7.2.1, Section 4.10.7.3.2, Section 4.10.7.3.3, Section 4.10.7.3.5, dBm. DL-UL Ratio Updated limitations when SW Version 4.1 Section 4.5.2.6.2 sub-channelization is enabled April 2007 Synchronization menu Updated structure of the SW Version 4.1 Section 4.5.2.7 Monitor April 2007 Licenses Updated feature description SW Version 4.1 Section 4.5.5 (distinction between local and April 2007 permanent CPE licenses) Show License Log New feature SW Version 4.1 Section 4.5.5.4 Create Backup April 2007 New option: BS License File Section 4.6.2.5 SW Version 4.1 April 2007 SU License Updated (Unit type affected by SW Version 4.1 Section 4.10.7.3.9 license)) April 2007 ODU - Show Summary Updated (Tx Power changed to SW Version 4.1 Section 4.8.1 Configured Tx Power, April 2007 Associated to AU:Channel added) iv BreezeMAX Modular Base Station System Manual Document History Topic Description Version/Date Issued ODU - Show (for a selected ODU) Updated (Tx Power changed to SW Version 4.1 Section 4.8.2.1 Configured Tx Power, April 2007 Associated to AU:Channel and Actual Tx Power added) ARQ ARQ Enable/Disable and SW Version 4.1 Section 4.9.5.1, Section 4.9.5.3.1, counters applicable for ARQ April 2007 Section 4.9.5.3.4, Section 4.9.6.1 enabled transmissions has been removed (in TDD system ARQ is always disabled) AU Unit Control-Show Versions Updated (Configured AU/SU SW SW Version 4.1 Section 4.9.5.2.3.1 Files added) April 2007 Actual Maximum Cell Radius New read-only parameter SW Version 4.1 Section 4.9.5.3.1.2 April 2007 AU Multi-Channel - Show Summary Tx Power changed to Configured SW Version 4.1 Section 4.9.5.3.3.1 Tx Power April 2007 Diversity Mode New Fourth Order Diversity SW Version 4.1 Section 4.9.5.3.3.2 modes April 2007 Full Sub-Channelization (OFDMA) Updated description of the SW Version 4.1 support Multirate algorithm and its April 2007 Section 4.9.5.3.4, Section 4.5.2.4 parameters. Updated description of ATPC algorithm. AU Minimum Allocation Updated parameter’s name and SW Version 4.1 Section 4.9.5.3.5.2 options April 2007 AU Ports Counters Back-Panel changed to Back SW Version 4.1 Section 4.9.6.1 Plane April 2007 BER Test New feature SW Version 4.1 Section 4.9.6.2 Selected SU Show menu April 2007 Updated Section 4.10.7.1 Antennas Specifications SW Version 4.1 April 2007 Updated Sections 1.5.2, 1.5.3, 1.5.10.4, SW Version 4.1 July 2007 1.5.10.5 Replacing a PIU Section 2.2.12.4 BreezeMAX Modular Base Station System Manual New SW Version 4.1 July 2007 Document History Topic Description Version/Date Issued CT in BE QoS CT in BE QoS is not SW Version 4.1 Sections 4.11.4.7, 4.11.4.7.3, configurable (set to Short) July 2007 Ber Test BER Test feature is not SW Version 4.1 Section 4.9.6.2 supported in current version July 2007 RADIUS description Added detailed description of SW Version 4.1 Section 4.5.4 SU authentication process July 2007 Minimum Number of Sub-Channels Default updated to 1 Table 4-14, Table 4-19, Table 4-22, Table 4-23, Sections B.3.6.3, B.5.6.3 Section 4.9.5.3.4.3, SW Version 4.1 July 2007 Antennas Specifications All antennas complies with ETSI SW Version 4.1 Sections 1.5.2 1.5.3 EN 302 326-3 V1.2.1 July 2007 Sensitivity Updated SW Version 4.1 Section 1.5.1 July 2007 Forwarding Rule selection in Service Updated description: L2 SW Version 4.1 Profile Forwarding Rule can be used in July 2007 Section 4.11.4.4.7 a VoIP Service Profile, and vice versa Unicast Relaying Updated description: Applicable SW Version 4.1 Section 4.11.4.5.3 only for L2 Forwarding Rules. July 2007 Added defaults for VoIP and PPPoE Forwarding Rules. Broadcast Relaying Updated description: Applicable SW Version 4.1 Section 4.11.4.5.4 only for L2 Forwarding Rules. July 2007 Added defaults for VoIP and PPPoE Forwarding Rules. Unknown Forwarding Policy Updated description: Applicable SW Version 4.1 Section 4.11.4.5.5 only for L2 Forwarding Rules. July 2007 Added defaults for VoIP and PPPoE Forwarding Rules. VoIP Services Updated names: Voice Service SW Version 4.1 Type changed to VoIP Service July 2007 Type Deleting an SU from the database Update description: only SW Version 4.1 Section 4.10.7.6 disconnected SUs can be July 2007 deleted. vi BreezeMAX Modular Base Station System Manual Document History Topic Description Version/Date Issued Forwarding Rules functionality Updated description SW Version 4.1 Section 4.11.1.1 L2, PPPoE and VoIP Services July 2007 Updated descriptions functionality SW Version 4.1 July 2007 Section 4.11.1.2 NPU Parameters Summary Section 4.12 BreezeMAX Modular Base Station System Manual Updated to reflect all changes SW Version 4.1 July 2007 vii Legal Rights Legal Rights © Copyright 2007 Alvarion Ltd. All rights reserved. The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd. Alvarion Ltd. reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. Trade Names Alvarion®, BreezeCOM®, WALKair®, WALKnet®, BreezeNET®, BreezeACCESS®, BreezeMANAGE™, BreezeLINK®, BreezeCONFIG™, BreezeMAX™, AlvariSTAR™, AlvariCRAFT™, BreezeLITE™, MGW™, eMGW™ and/or other products and/or services referenced here in are either registered trademarks, trademarks or service marks of Alvarion Ltd. All other names are or may be the trademarks of their respective owners. Statement of Conditions The information contained in this manual is subject to change without notice. Alvarion Ltd. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual or equipment supplied with it. Warranties and Disclaimers All Alvarion Ltd. ("Alvarion") products purchased from Alvarion or through any of Alvarion's authorized resellers are subject to the following warranty and product liability terms and conditions. Exclusive Warranty (a) Alvarion warrants that the Product hardware it supplies and the tangible media on which any software is installed, under normal use and conditions, will be free from significant defects in materials and workmanship for a period of fourteen (14) months from the date of shipment of a given Product to Purchaser (the "Warranty Period"). Alvarion will, at its sole option and as Purchaser's sole remedy, repair or replace any defective Product in accordance with Alvarion' standard R&R procedure. (b) With respect to the Firmware, Alvarion warrants the correct functionality according to the attached documentation, for a period of fourteen (14) month from viii BreezeMAX Modular Base Station System Manual Legal Rights invoice date (the "Warranty Period")". During the Warranty Period, Alvarion may release to its Customers firmware updates, which include additional performance improvements and/or bug fixes, upon availability (the "Warranty"). Bug fixes, temporary patches and/or workarounds may be supplied as Firmware updates. Additional hardware, if required, to install or use Firmware updates must be purchased by the Customer. Alvarion will be obligated to support solely the two (2) most recent Software major releases. ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY PURCHASER'S OR ANY THIRD PERSON'S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR IMPROPER TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING OR OTHER HAZARD. Disclaimer (a) The Software is sold on an "AS IS" basis. Alvarion, its affiliates or its licensors MAKE NO WARRANTIES, WHATSOEVER, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING DOCUMENTATION. ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT WITH RESPECT TO THE SOFTWARE. UNITS OF PRODUCT (INCLUDING ALL THE SOFTWARE) DELIVERED TO PURCHASER HEREUNDER ARE NOT FAULT-TOLERANT AND ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE IN APPLICATIONS WHERE THE FAILURE, MALFUNCTION OR INACCURACY OF PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE ("HIGH RISK ACTIVITIES"). HIGH RISK ACTIVITIES MAY INCLUDE, BUT ARE NOT LIMITED TO, USE AS PART OF ON-LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR TRAFFIC CONTROL, LIFE SUPPORT MACHINES, WEAPONS SYSTEMS OR OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL HAZARD. ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES. (b) PURCHASER'S SOLE REMEDY FOR BREACH OF THE EXPRESS WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE PURCHASE PRICE AS SPECIFIED ABOVE, AT ALVARION'S OPTION. TO THE FULLEST EXTENT ALLOWED BY LAW, THE WARRANTIES AND REMEDIES SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER BreezeMAX Modular Base Station System Manual ix Legal Rights WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING BUT NOT LIMITED TO WARRANTIES, TERMS OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, NON-INFRINGEMENT, AND ACCURACY OF INFORMATION GENERATED. ALL OF WHICH ARE EXPRESSLY DISCLAIMED. ALVARION' WARRANTIES HEREIN RUN ONLY TO PURCHASER, AND ARE NOT EXTENDED TO ANY THIRD PARTIES. ALVARION NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. Limitation of Liability (a) ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY, FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF BUSINESS OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER ARISING UNDER BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. (b) TO THE EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY PURCHASER, NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID FOR THAT PRODUCT BY THAT PARTY (EXCEPT IN THE CASE OF A BREACH OF A PARTY'S CONFIDENTIALITY OBLIGATIONS). Radio Frequency Interference Statement The Subscriber Unit equipment has been tested and found to comply with the limits for a class B digital device, pursuant to ETSI EN 301 489-1 rules and Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment notwithstanding use in commercial, business and industrial environments. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. The Base Station equipment has been tested and found to comply with the limits for a class A digital device, pursuant to ETSI EN 301 489-1 rules and Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial, business BreezeMAX Modular Base Station System Manual Legal Rights and industrial environments. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user's own expense. FCC Radiation Hazard Warning Base Station - To comply with FCC RF exposure requirements in Section 1.1307 and 2.1091 of FCC Rules, the antenna used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 meter from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Indoor CPE - To comply with FCC RF exposure requirements in Section 1.1307and 2.1091 of FCC Rules, the antenna used for this transmitter must be kept at a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Outdoor CPE - To comply with FCC RF exposure requirements in Section 1.1307 and 2.1091 of FCC Rules, the antenna be used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 120 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. R&TTE Compliance Statement This equipment complies with the appropriate essential requirements of Article 3 of the R&TTE Directive 1999/5/EC. Safety Considerations - General For the following safety considerations, "Instrument" means the BreezeMAX units' components and their cables. Grounding Base Station chassis, Power Feeders and outdoor units are required to be bonded to protective grounding using the bonding stud or screw provided with each unit. BreezeMAX Modular Base Station System Manual xi Legal Rights Safety Considerations - DC Powered Equipment (BST & Power Feeder) CAUTION ATTENTION Risk of electric shock and energy hazard.Disconnecting one Power Interface Unit (PIU) disconnects only one PIU module. To isolate the Base Station completely, disconnect both PIUs Risque de décharge électrique et d'electrocution. La déconnection d'un seul module d'alimentation (PIU) n'isole pas complètement la Station de Base. Pour cela, il faut impérativement débrancher les deux modules d'alimentation (PIU). Restricted Access Area: The DC powered equipment should only be installed in a Restricted Access Area. Installation Codes: The equipment must be installed according to the latest edition of the country national electrical codes. For North America, equipment must be installed in accordance with the US National Electrical Code and the Canadian Electrical Code. Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 40A for the modular Base Station or 20A for the Power Feeder, must be incorporated in the building wiring. CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the grounding conductor at the equipment. See installation instructions. The equipment must be connected directly to the DC Supply System grounding electrode conductor. All equipment in the immediate vicinity must be grounded in the same way, and not be grounded elsewhere. The DC supply system is to be local, i.e. within the same premises as the equipment. There shall be no disconnect device between the grounded circuit conductor of the DC source (return) and the point of connection of the grounding electrode conductor. Lithium Battery The battery on the NPU card is not intended for replacement. xii BreezeMAX Modular Base Station System Manual Legal Rights Caution To avoid electrical shock, do not perform any servicing unless you are qualified to do so. Line Voltage Before connecting this instrument to the power line, make sure that the voltage of the power source matches the requirements of the instrument. Radio The instrument transmits radio energy during normal operation. To avoid possible harmful exposure to this energy, do not stand or work for extended periods of time in front of its antenna. The long-term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not been yet fully investigated. Outdoor Units and Antennas Installation and Grounding Ensure that outdoor units, antennas and supporting structures are properly installed to eliminate any physical hazard to either people or property. Make sure that the installation of the outdoor unit, antenna and cables is performed in accordance with all relevant national and local building and safety codes. Even where grounding is not mandatory according to applicable regulation and national codes, it is highly recommended to ensure that the outdoor unit and the antenna mast (when using external antenna) are grounded and suitable lightning protection devices are used so as to provide protection against voltage surges and static charges. In any event, Alvarion is not liable for any injury, damage or regulation violations associated with or caused by installation, grounding or lightning protection. Disposal of Electronic and Electrical Waste Disposal of Electronic and Electrical Waste Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product. BreezeMAX Modular Base Station System Manual xiii Legal Rights Important Notice This user manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information belonging to Alvarion Ltd. Such information is supplied solely for the purpose of assisting properly authorized users of the respective Alvarion products. No part of its contents may be used for any other purpose, disclosed to any person or firm or reproduced by any means, electronic and mechanical, without the express prior written permission of Alvarion Ltd. The text and graphics are for the purpose of illustration and reference only. The specifications on which they are based are subject to change without notice. The software described in this document is furnished under a license. The software may be used or copied only in accordance with the terms of that license. Information in this document is subject to change without notice. Corporate and individual names and data used in examples herein are fictitious unless otherwise noted. Alvarion Ltd. reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. The information contained herein is merely descriptive in nature, and does not constitute an offer for the sale of the product described herein. Any changes or modifications of equipment, including opening of the equipment not expressly approved by Alvarion Ltd. will void equipment warranty and any repair thereafter shall be charged for. It could also void the user's authority to operate the equipment. Some of the equipment provided by Alvarion and specified in this manual, is manufactured and warranted by third parties. All such equipment must be installed and handled in full compliance with the instructions provided by such manufacturers as attached to this manual or provided thereafter by Alvarion or the manufacturers. Non-compliance with such instructions may result in serious xiv BreezeMAX Modular Base Station System Manual Legal Rights damage and/or bodily harm and/or void the user's authority to operate the equipment and/or revoke the warranty provided by such manufacturer. BreezeMAX Modular Base Station System Manual xv About This Manual This manual describes the BreezeMAX TDD ("BreezeMAX") Base Station equipment, and details how to install, operate and manage the system components. This manual is intended for technicians responsible for installing, setting and operating the BreezeMAX Base Station equipment, and for system administrators responsible for managing the system. This manual contains the following chapters and appendices: Chapter 1 - System description: Describes the BreezeMAX system and its components. Chapter 2 - Installation: Describes how to install the Base Station system components. Chapter 3 - Commissioning: Describes how to configure basic parameters and validate units' operation. Chapter 4 - Operation and Administration: Describes how to use the Monitor application for configuring parameters, checking system status and monitoring performance. Appendix A - Software Upgrade: Describes how to load new software files using TFTP, and how to switch to a new software version in BreezeMAX units. Appendix B - Defining Service Profiles for Generic VoIP Gateways: Describes the principles of defining Service Profiles for 3rd party generic (non DRAP based) VoIP devices. Glossary: A listing of commonly used terms. Index Contents Chapter 1 - System Description 1.1 Introducing BreezeMAX................................................................................................ 2 1.2 Base Station Equipment ............................................................................................... 6 1.2.1 Base Station Chassis ........................................................................................... 6 1.2.2 Network Processing Unit (NPU)........................................................................... 6 1.2.3 Access Unit (AU-IDU) .......................................................................................... 7 1.2.4 AU-ODU-HP......................................................................................................... 8 1.2.5 Base Station Radio Configurations ...................................................................... 8 1.2.6 Power Feeder..................................................................................................... 10 1.2.7 Power Interface Unit (PIU) ................................................................................. 11 1.2.8 Power Supply Unit (PSU)................................................................................... 12 1.2.9 Air Ventilation Unit (AVU)................................................................................... 12 1.2.10 GPS.................................................................................................................... 12 1.3 Networking Equipment ............................................................................................... 14 1.3.1 DUET 6004 Access Gateway............................................................................. 14 1.4 Management Systems................................................................................................. 15 1.4.1 AlvariSTAR™ ..................................................................................................... 15 1.4.2 AlvariCRAFT™................................................................................................... 16 1.4.3 BreezeMAX Service Manager............................................................................ 17 1.5 Specifications .............................................................................................................. 18 1.5.1 Radio.................................................................................................................. 18 1.5.2 Base Station 2.X GHz Antennas (Optional) ....................................................... 20 1.5.3 Base Station 3.x GHz Antennas (Optional)........................................................ 21 Contents 1.5.4 AU-IDU to AU-ODU Communication.................................................................. 22 1.5.5 Data Communication (Ethernet Ports) ............................................................... 22 1.5.6 Configuration and Management......................................................................... 23 1.5.7 Environmental .................................................................................................... 23 1.5.8 Standards Compliance, General ........................................................................ 24 1.5.9 Services ............................................................................................................. 25 1.5.10 Physical and Electrical ....................................................................................... 26 Chapter 2 - Installation Guidelines 2.1 Installing the AU-ODU................................................................................................. 32 2.1.1 AU-ODU Installation Requirements ................................................................... 32 2.1.2 Guidelines for Positioning the AU-ODU ............................................................. 33 2.1.3 IF Cables............................................................................................................ 33 2.1.4 Pole Mounting the ODU ..................................................................................... 34 2.1.5 AU-ODU ............................................................................................................. 38 2.1.6 Connecting the Cables....................................................................................... 39 2.2 Installing the Base Station Equipment...................................................................... 41 2.2.1 BST Installation Requirements........................................................................... 41 2.2.2 BMAX-BST-SH Chassis Slot Assignments ........................................................ 42 2.2.3 Power Requirements.......................................................................................... 43 2.2.4 HOT SWAP Support .......................................................................................... 44 2.2.5 Power Interface Unit (PIU) ................................................................................. 44 2.2.6 Power Supply Unit (PSU)................................................................................... 48 2.2.7 Access Unit Indoor Module (AU-IDU) ................................................................ 51 2.2.8 Network Processing Unit (NPU)......................................................................... 53 2.2.9 Using the Hot Swap Injector/Ejector Handles .................................................... 55 2.2.10 Installing the Base Station Chassis and Modules .............................................. 57 xviii BreezeMAX Modular Base Station System Manual Contents 2.2.11 Air Ventilation Unit (AVU)................................................................................... 59 2.2.12 Replacing Base Station Components ................................................................ 59 2.3 Installing the ODU Power Feeder............................................................................... 63 2.3.1 Installation Requirements................................................................................... 63 2.3.2 The ODU Power Feeder .................................................................................... 64 2.3.3 Installing the ODU Power Feeder ...................................................................... 65 2.4 Installing the GPS Adapter ........................................................................................ 67 2.4.1 Installation Requirements................................................................................... 67 2.4.2 The GPS Adapter............................................................................................... 68 2.4.3 Installing the GPS Adapter................................................................................. 69 2.4.4 NPU to GPS Adapter Cable ............................................................................... 71 2.4.5 GPS Adapter to Outdoor GPS Receiver Cable.................................................. 72 Chapter 3 - Commissioning 3.1 Configuring Basic Parameters of Base Station........................................................ 74 3.1.1 NPU Parameters Required for Management ..................................................... 74 3.1.2 Base Station Configuration Parameters............................................................. 76 3.1.3 RADIUS Parameters .......................................................................................... 76 3.1.4 Radio Cluster ..................................................................................................... 77 3.1.5 ODU ................................................................................................................... 77 3.1.6 AU ...................................................................................................................... 78 3.1.7 SU ...................................................................................................................... 79 3.2 Operation Verification................................................................................................. 80 3.2.1 AU-ODU LEDs ................................................................................................... 80 3.2.2 Base Station LEDs ............................................................................................. 80 3.2.3 ODU Power Feeder LEDs.................................................................................. 84 3.2.4 GPS Adapter LEDs ............................................................................................ 84 BreezeMAX Modular Base Station System Manual xix Contents 3.2.5 Verifying the Ethernet Connection ..................................................................... 85 Chapter 4 - Operation and Administration 4.1 BreezeMAX System Management.............................................................................. 88 4.2 The Monitor Program .................................................................................................. 90 4.2.1 Accessing the Monitor Program ......................................................................... 90 4.2.2 Using the Monitor Program ................................................................................ 91 4.3 IP Addresses Configuration ....................................................................................... 94 4.4 The NPU's Main Menu ................................................................................................. 95 4.4.1 Base Station Menu............................................................................................. 95 4.4.2 NPU Menu.......................................................................................................... 95 4.4.3 Radio Cluster Menu ........................................................................................... 95 4.4.4 ODU Menu ......................................................................................................... 95 4.4.5 AU Menu ............................................................................................................ 96 4.4.6 SU Menu ............................................................................................................ 96 4.4.7 Services Menu ................................................................................................... 96 4.4.8 Exit ..................................................................................................................... 96 4.5 Base Station Menu ...................................................................................................... 97 4.5.1 Show .................................................................................................................. 97 4.5.2 Configuration...................................................................................................... 98 4.5.3 Alarms and Traps............................................................................................. 110 4.5.4 RADIUS............................................................................................................ 113 4.5.5 Licenses ........................................................................................................... 122 4.6 NPU Menu .................................................................................................................. 125 4.6.1 Show ................................................................................................................ 125 4.6.2 Unit Control ...................................................................................................... 127 4.6.3 Configuration.................................................................................................... 132 xx BreezeMAX Modular Base Station System Manual Contents 4.6.4 Performance Monitoring................................................................................... 139 4.7 Radio Cluster Menu................................................................................................... 143 4.7.1 Show Summary................................................................................................ 143 4.7.2 Select ............................................................................................................... 144 4.7.3 Add................................................................................................................... 144 4.7.4 Radio Cluster Parameters................................................................................ 144 4.8 ODU Menu .................................................................................................................. 146 4.8.1 Show Summary................................................................................................ 146 4.8.2 Select ............................................................................................................... 147 4.8.3 Add................................................................................................................... 148 4.8.4 ODU Parameters.............................................................................................. 148 4.8.5 Frequency Bands File and Frequency Bands Groups ..................................... 150 4.9 AU Menu.....................................................................................................................152 4.9.1 Show Summary................................................................................................ 152 4.9.2 Upgrading AU’s SW ......................................................................................... 154 4.9.3 SW Files in NPU .............................................................................................. 154 4.9.4 Select ............................................................................................................... 156 4.9.5 AU Slot # Menu ................................................................................................ 156 4.9.6 Performance Monitoring................................................................................... 170 4.10SU Menu .................................................................................................................... 172 4.10.1 Show Summary................................................................................................ 172 4.10.2 Show Summary by AU ..................................................................................... 175 4.10.3 Upgrading SU’s SW ......................................................................................... 175 4.10.4 SW Files in NPU .............................................................................................. 175 4.10.5 Select by Name................................................................................................ 177 4.10.6 Select by MAC Address ................................................................................... 177 BreezeMAX Modular Base Station System Manual xxi Contents 4.10.7 SU # Menu ....................................................................................................... 177 4.10.8 Add New SU..................................................................................................... 198 4.10.9 Clear All Configured SU SW Files.................................................................... 198 4.11Services Menu........................................................................................................... 199 4.11.1 Introduction to Services.................................................................................... 199 4.11.2 Introduction to Filtering Features ..................................................................... 207 4.11.3 Common Operations in Services Menu ........................................................... 208 4.11.4 The Services Menu .......................................................................................... 209 4.11.5 Defining Service Profiles .................................................................................. 235 4.11.6 Defining Local (Permanent) Services............................................................... 236 4.11.7 Defining RADIUS Based Services ................................................................... 236 4.11.8 Pre-configured Profiles..................................................................................... 237 4.12NPU Parameters Summary ...................................................................................... 243 A.1 Before you Start ........................................................................................................ 260 A.2 File Loading Procedure ............................................................................................ 261 A.3 Completing the Software Upgrade (Switching Versions)...................................... 263 B.1 Introduction ............................................................................................................... 266 B.1.1 Priority Marking ................................................................................................ 266 B.1.2 General Assumptions....................................................................................... 266 B.2 1 POTS Basic VoIP G.729 Service Profile ............................................................... 268 B.2.1 Service Characteristics .................................................................................... 268 B.2.2 RTP BW Calculation ........................................................................................ 268 B.2.3 RTCP BW Calculation...................................................................................... 268 B.2.4 QoS Profile....................................................................................................... 268 B.3 1 POTS Advanced VoIP G.729 Service Profile........................................................ 270 B.3.1 Service Characteristics .................................................................................... 270 xxii BreezeMAX Modular Base Station System Manual Contents B.3.2 Voice RTP BW Calculation .............................................................................. 270 B.3.3 Voice RTCP BW Calculation............................................................................ 270 B.3.4 T.38 14,400 Kbps Fax RTP BW Calculation .................................................... 270 B.3.5 FAX RTCP BW Calculation.............................................................................. 271 B.3.6 QoS Profiles ..................................................................................................... 271 B.4 1 POTS Basic VoIP G.711 Service Profile ............................................................... 272 B.4.1 Service Characteristics .................................................................................... 272 B.4.2 RTP BW Calculation ........................................................................................ 272 B.4.3 RTCP BW Calculation...................................................................................... 272 B.4.4 QoS Profile....................................................................................................... 272 B.5 1 POTS Advanced VoIP G.711 Service Profile........................................................ 274 B.5.1 Service Characteristics .................................................................................... 274 B.5.2 Voice RTP BW Calculation .............................................................................. 274 B.5.3 Voice RTCP BW Calculation............................................................................ 274 B.5.4 T.38 14,400 Kbps Fax RTP BW Calculation .................................................... 274 B.5.5 FAX RTCP BW Calculation.............................................................................. 275 B.5.6 QoS Profiles ..................................................................................................... 275 BreezeMAX Modular Base Station System Manual xxiii Figures Figure 1-1: BreezeMAX System Architecture................................................................................ 5 Figure 2-1: AU-ODU-HP Pole Installation Using Special Clamps ............................................... 36 Figure 2-2: AU-ODU-HP Pole Installation Using Metal Band...................................................... 37 Figure 2-3: Bottom Panel of the AU-ODU (except 2.3 GHz WCS).............................................. 38 Figure 2-4: Bottom Panel of the AU-ODU - 2.3 GHz WCS ......................................................... 38 Figure 2-5: BMAX-BST-SH Chassis Slot Assignments............................................................... 42 Figure 2-6: Regular (35A) PIU Module Front Panel .................................................................... 45 Figure 2-7: High-Power (58A) PIU Module Front Panel .............................................................. 46 Figure 2-8: PSU Module Front Panel .......................................................................................... 49 Figure 2-9: AU-IDU Module Front Panel ..................................................................................... 51 Figure 2-10: NPU Module Front Panel ........................................................................................ 53 Figure 2-11: AVU Drawer Front Panel ........................................................................................ 59 Figure 2-12: ODU Power Feeder Front Panel............................................................................. 64 Figure 2-13: ODU Power Feeder Rear Panel ............................................................................. 64 Figure 2-14: GPS Adapter Front Panel ....................................................................................... 68 Figure 2-15: GPS Adapter Rear Panel........................................................................................ 68 Figure 4-1: Base Station Chassis Slot Assignment..................................................................... 98 Figure 4-2: Filtering Functionality .............................................................................................. 207 Tables Table 1-1: Number of AU-IDUs, AU-ODUs and Power Feeders Required for Various Configurations with regular PIU(s) .............................................................................................................. 11 Table 1-2: Number of AU-IDUs, AU-ODUs and Power Feeders Required for Various Configurations with High-Power PIU(s) ...................................................................................................... 11 Table 1-3: PSU Requirements, Configurations with one NPU (excluding PSU redundancy) ..... 12 Table 1-4: Radio Specifications................................................................................................... 18 Table 1-5: Base Station 2.X GHz Antennas, Electrical Specifications ........................................ 20 Table 1-6: Base Station 3.x GHz Antennas, Electrical Specifications......................................... 21 Table 1-7: AU-IDU to AU-ODU Communication.......................................................................... 22 Table 1-8: Data Communication (Ethernet Ports) ....................................................................... 22 Table 1-9: Configuration and Management................................................................................. 23 Table 1-10: Environmental Specifications ................................................................................... 23 Table 1-11: Standards Compliance, General .............................................................................. 24 Table 1-12: Services ................................................................................................................... 25 Table 1-13: Mechanical Specifications, Base Station Equipment ............................................... 26 Table 1-14: Electrical Specifications, Base Station Equipment................................................... 27 Table 1-15: Connectors, Base Station Equipment ...................................................................... 28 Table 1-16: Base Station 2.X GHz Antennas, Mechanical Specifications................................... 29 Table 1-17: Base Station 3.x GHz Antennas, Mechanical Specifications ................................... 30 Table 2-1: IF Cables Requirements ............................................................................................ 34 Table 2-2: Maximum IF Cable Length (Double Shielded Cables) ............................................... 34 Table 2-3: AU-ODU LEDs ........................................................................................................... 39 Table 2-4: AU-ODU Connectors.................................................................................................. 39 Table 2-5: Power Requirements, Base Station Equipment ......................................................... 43 Tables Table 2-6: PIU LEDs ................................................................................................................... 47 Table 2-7: PSU Requirements, Configurations with one NPU (excluding PSU redundancy) ..... 49 Table 2-8: PSU LEDs .................................................................................................................. 50 Table 2-9: AU-IDU LEDs ............................................................................................................. 52 Table 2-10: NPU Connectors ...................................................................................................... 54 Table 2-11: NPU LEDs................................................................................................................ 54 Table 2-12: AVU LEDs ................................................................................................................ 59 Table 2-13: ODU Power Feeder Connectors .............................................................................. 64 Table 2-14: ODU Power Feeder LEDs........................................................................................ 65 Table 2-15: GPS Adapter Connectors......................................................................................... 68 Table 2-16: GPS Adapter LEDs .................................................................................................. 69 Table 2-17: NPU to GPS Adapter Cable Pin Out ........................................................................ 71 Table 2-18: GPS Adapter to Outdoor GPS Receiver Cable Pin Out........................................... 72 Table 3-1: Basic NPU Parameters .............................................................................................. 74 Table 3-2: AU-ODU-LEDs ........................................................................................................... 80 Table 3-3: AU-IDU LEDs ............................................................................................................. 81 Table 3-4: NPU LEDs.................................................................................................................. 82 Table 3-5: PIU LEDs ................................................................................................................... 83 Table 3-6: PSU LEDs .................................................................................................................. 83 Table 3-7: AVU LEDs .................................................................................................................. 83 Table 3-8: ODU Power Feeder LEDs.......................................................................................... 84 Table 3-9: GPS Adapter LEDs ....................................................................................................84 Table 4-1: COM Port Configuration............................................................................................. 90 Table 4-2: IP CS Switching Mode Functional Changes ............................................................ 100 Table 4-3: Default Passwords ................................................................................................... 128 Table 4-4: Frequency Bands ..................................................................................................... 150 xxviii BreezeMAX Modular Base Station System Manual Tables Table 4-5: Automatic Association of Channel 1 Upon First Power-Up...................................... 164 Table 4-6: Rates (Modulation Schemes and Coding) ............................................................... 168 Table 4-7: Scanning Intermediate Steps ................................................................................... 194 Table 4-8: Hybrid VLAN Mode .................................................................................................. 205 Table 4-9: Hybrid VLAN Mode .................................................................................................. 213 Table 4-10: Priority Marking Values .......................................................................................... 221 Table 4-11: Pre-Configured Data Service Profiles .................................................................... 238 Table 4-12: Pre-Configured Forwarding Rules for Data Service............................................... 239 Table 4-13: Pre-Configured Priority Classifiers for Data Services ............................................ 239 Table 4-14: Pre-Configured QoS Profiles for Data Services ..................................................... 240 Table 4-15: Pre-Configured VoIP Service Profiles (for DRAP-based Gateways) .................... 240 Table 4-16: Pre-Configured Service Profiles for Generic (non-DRAP) VoIP Services.............. 240 Table 4-17: Pre-Configured Forwarding Rule for VoIP Services............................................... 241 Table 4-18: Pre-Configured Priority Classifiers for Generic (non-DRAP) VoIP Service............ 241 Table 4-19: Pre-Configured BE and RT QoS Profile for VoIP Services .................................... 242 Table 4-20: Pre-Configured CG QoS Profile for Generic (non-DRAP) VoIP Services .............. 242 Table 4-21: Pre-Configured Forwarding Rule for Transparent Services ................................... 242 Table 4-22: Pre-Configured QoS Profile for Transparent Services ........................................... 242 Table 4-23: NPU Monitor Parameters Summary....................................................................... 243 BreezeMAX Modular Base Station System Manual xxix 1 Chapter 1 - System Description In This Chapter: “Introducing BreezeMAX” on page 2 “Base Station Equipment” on page 6 “Networking Equipment” on page 14 “Management Systems” on page 15 “Specifications” on page 18 Chapter 1 - System Description 1.1 Introducing BreezeMAX BreezeMAX TDD (BreezeMAX) is Alvarion's WiMAX compatible platform operating in Time Division Duplex (TDD) mode. It leverages Alvarion's market-leading knowledge of Broadband Wireless Access (BWA), industry leadership, proven field experience, and core technologies including many years of experience with OFDM technology. Built from the ground up based on the IEEE 802.16/ETSI HIPERMAN standards, BreezeMAX is designed specifically to meet the unique requirements of the wireless Metropolitan Area Network (MAN) environment and to deliver broadband access services to a wide range of customers, including residential, SOHO, SME and multi-tenant customers. Its Media Access Control (MAC) protocol was designed for point-to-multipoint broadband wireless access applications, providing a very efficient use of the wireless spectrum and supporting difficult user environments. The access and bandwidth allocation mechanisms accommodate hundreds of subscriber units per channel, with subscriber units that may support different services to multiple end users. The system uses OFDM radio technology, which is robust in adverse channel conditions and enables operation in non line of sight links. This allows easy installation and improves coverage, while maintaining a high level of spectral efficiency. n the uplink the system uses OFDMA-16, supporting N x Subscriber Units per Symbol (N=1 to 16). Modulation and coding can be adapted per burst, ever striving to achieve a balance between robustness and efficiency in accordance with prevailing link conditions. BreezeMAX supports a wide range of network services, including Internet access (via IP or PPPoE tunneling), VPNs and Voice over IP. Service recognition and multiple classifiers that can be used for generating various service profiles enable operators to offer differentiated SLAs with committed QoS for each service profile. The system supports also IP CS Switching Mode that is compatible with the infrastructure of next generation WiMAX systems, providing VPN/L2TP support using a DHCP proxy in the NPU . IP CS Switching Mode provides smooth upgrade to systems that fully support the IEEE 802.16e standard, with the same “Look and Feel” of service provisioning. BreezeMAX offers an innovative solution for a Self-Install CPE, including all the features, embedded capabilities and supplementary tools that support easy installation by a non-professional user and fully automated network-entry, authentication and services provisioning. The elements that enable and support the Self-Install solution include: System Description Introducing BreezeMAX 4-channel Access Unit and high-power radios at the Base Station 2nd or 4th order transmit diversity at the Base Station. 4th order receive diversity at the Base Station using Maximum Receive Ratio Combining (MRRC). Uplink sub-channels using OFDMA-16 for increased service efficiency and improved link budget. A high-power CPE with an integral antenna array, providing 360 degrees coverage with smart selection of Tx and Rx antennas. An optional wall/window mounted antenna to extend the coverage area. Automatic frequency scanning and best Access Unit/Base Station selection algorithms in the CPE. Enhanced Automatic Transmit Power Control (ATPC) and dynamic rate selection (multirate) optimized for multiple sub-channels in the uplink. Centralized CPE authentication and service provisioning using either a commercial RADIUS server or an entry level BreezeMAX Service Manager server available from Alvarion. Centralized Service Profiles distribution to ensure location-free service availability and fully controlled service provisioning. A suite of features and support tools to enable fast and simple installation according to various business models. The system operates in Time Division Duplex (TDD) and is currently available in the 2.3 GHz (WCS), 2.5 GHz (MMDS and MCS), 3.3 GHz and 3.5 GHz frequency bands. The actual operating frequencies used by the system can be configured according to applicable radio regulations, license conditions and specific deployment considerations. A BreezeMAX system comprises of the following: Customer Premise Equipment (CPE): BreezeMAX Subscriber Units and Alvarion's Voice/Networking Gateways. BreezeMAX Modular Base Station System Manual Chapter 1 - System Description Base Station (BST) Equipment: BreezeMAX Base Station equipment, including the modular Base Station, Outdoor Radio Units, GPS Receiver and other components. Networking Equipment: Standard switches/routers and other networking equipment, supporting connections to the backbone and/or Internet. Management Systems: SNMP-based Management, RADIUS server(s) and other Operation Support Systems. System Description Introducing BreezeMAX Figure 1-1: BreezeMAX System Architecture BreezeMAX Modular Base Station System Manual Chapter 1 - System Description 1.2 Base Station Equipment The Multi Carrier, High Power, Full Duplex Base Station provides all the functionality necessary to communicate with SUs and to connect to the backbone of the Service Provider. The Base Station comprises the following elements: 1.2.1 Base Station Chassis The Base Station equipment is based on an 8U high cPCI (compact Peripheral Component Interconnect) shelf designed for installation in a 19" or 21" (ETSI) rack. This chassis has a total of nine double Euro (6U high) slots and six single Euro (3U high) slots. All the modules are hot swappable, and high availability can be provided through multiple redundancy schemes. The six single Euro slots are intended for one or two redundant Power Interface Units (PIU) and up to four redundant Power Supply Units (PSUs). One of the double Euro slots is dedicated to the Network Processing Unit (NPU) module, supporting a central networking and management architecture. Another double Euro slot is reserved for an optional redundant NPU (NPU redundancy support is planned for a future release). The remaining seven double Euro slots are dedicated mainly for Access Unit (AU) indoor modules, thus enabling various future redundancy configurations. Additionally, the Base Station chassis contains an air convection and ventilation fan tray (AVU). 1.2.2 Network Processing Unit (NPU) The Network Processing Unit is the "heart" of the BreezeMAX Base Station. The NPU module serves as the central processing unit that manages the base station's components and the SUs served by it. It also aggregates the traffic from the AU modules and transfers it to the IP Backbone through a dedicated Gigabit/Fast Ethernet interface. The NPU main functions are: System Description Base Station Equipment Aggregate backbone Ethernet connectivity via a 100/1000 Base-T network interface. Traffic classification and connection establishment initiation. Policy based data switching. Service Level Agreements management. RADIUS NAS, enabling centralized SUs’ authentication and services authorization by RADIUS server(s). Centralized agent in the Base Station to manage all cell site's AUs and all registered SUs. Base Station overall operation control, including AU diagnostic and control, PSU monitoring, AVU management and redundancy support. Alarms management, including external alarm inputs and activation of external devices (future option). Synchronization, including GPS antenna interface, clock and IF reference generation and distribution to the Base Station modules as well as to other collocated Base Station chassis (future option). An SNMP agent incorporated into the NPU enables extensive In Band (IB) management of the Base Station and all its registered SUs. Out Of Band (OOB) management is supported through a dedicated 10/100 Base-T interface. A serial RS-232 port supports local configuration, monitoring and debugging. Two NPU modules can be used to provide a 1+1 redundancy scheme. The redundancy mechanism, to be supported in future releases, will be based on a Master <-> Slave principle, where the slave is in passive mode and is constantly updating all the learning tables and networking parameters of the master card. 1.2.3 Access Unit (AU-IDU) The double Euro AU-IDU module contains the WiMAX-ready MAC and modem and is responsible for the wireless network connection establishment and for bandwidth management. Each AU-IDU connects to the NPU via the back plane. In addition, each AU-IDU connects to all other AU slots via the back plane over a shared bus. BreezeMAX Modular Base Station System Manual Chapter 1 - System Description Each AU-IDU includes four channels using a common PHY and MAC that can connect to up to four outdoor radio units, according to the selected diversity mode (refer to Section 1.2.5 below for more details). The AU-IDU module connects to the AU-ODUs via Intermediate Frequency (IF) cables carrying full duplex data, control and management signals between the AU-IDU and the AU-ODU, as well as power (-48 VDC) and 64 MHz synchronization reference clock from the AU-IDU to the AU-ODU. The IF Tx and Rx frequencies are 240 MHz and 140 MHz, respectively. IDU-ODU service channel at 14 MHz serves for bi-directional control, status and management signaling. 1.2.4 AU-ODU-HP The AU-ODU-HP (High Power ODU) is a full duplex multi-carrier radio unit that connects to an external antenna. It is designed to provide high system gain and interference robustness utilizing high transmit power and low noise figure. 1.2.5 Base Station Radio Configurations The 4-Channel High-Power AU-IDUs support the following radio configurations: 1.2.5.1 Single Channel per AU, No Diversity This is the basic configuration, where each AU-IDU connects to one ODU, serving a single sector with a directional antenna. 1.2.5.2 Multiple Channels per AU, No Diversity Up to 4 channels per AU-IDU can be used to cover several sectors, where each channel connects to one ODU, with one ODU per sector. A single AU-IDU can cover a 360° cell. Where the coverage of the cell can be built from 3 sectors of 120° each with frequency reuse 1, or 4 sectors of 90° each with frequency reuse 1 (i.e. frequency per sector) or 1/2 (i.e. 2 frequencies for 4 sectors where each frequency is used for 2 opposite sectors). All ODUs served by the same AU-IDU share a common MAC and modem. Each ODU is managed separately. System Description Base Station Equipment The following figure describes the multi channel use to cover a cell of 360° with 4 sectors, using frequency reuse 1: The following figure describes the multi channel use to cover a cell of 360° with 4 sectors, using frequency reuse 1/2: 1.2.5.3 2nd Order Diversity Multiple channel configuration with second order diversity allows coverage of one sector with space diversity by a single AU-IDU and two ODUs connected to channels 1 and 2. The same frequency and transmit power are set for both ODUs. The two ODUs served by the same AU-IDU share a common MAC and modem. BreezeMAX Modular Base Station System Manual Chapter 1 - System Description 1.2.5.4 4th Order Diversity Multiple channel configuration with fourth order diversity allows a single sector coverage by a single AU-IDU with 4 ODUs. In each sector, both space and polarization diversities are implemented, using dual polarization slant antennas. The channels are paired: channels 1 and 2 form one pair, channels 3 and 4 form the second pair. The two ODUs connected to each pair are connected to the same dual polarization antenna. The same frequency and transmit power are set for all four ODUs. All ODUs served by the same AU-IDU share a common MAC and modem. 1.2.6 Power Feeder The Base station’s regular PIU can support a maximum current of 35 A (@-40.5 VDC). Using proper design considerations, up to eight AU-ODU-HP units can be powered directly from the Base Station (via the back panel and AU-IDUs). The High-Power PIU can support a maximum current of 58 A, enabling support of up to 20 AU-ODU-HP units. The ODU Power Feeder is used as an additional power source providing power (-48 VDC) to AU-ODU-HP High Power ODUs. It transfers transparently all signals between the AU-IDU and the ODU, while injecting DC power received from an external source. Each ODU Power Feeder unit can serve up to four High Power ODUs. Up to three ODU Power Feeder units can be installed in a 1U high Power Feeder panel. The following tables displays the number of ODUs and Power Feeder modules required for various radio configurations and different PIU types: 10 System Description Base Station Equipment Table 1-1: Number of AU-IDUs, AU-ODUs and Power Feeders Required for Various Configurations with regular PIU(s) Diversity Mode Number of Sectors (AU-IDUs) Number of ODUs Number of Power Feeders Second Order Diversity 12 12 16 24 Fourth Order Diversity Table 1-2: Number of AU-IDUs, AU-ODUs and Power Feeders Required for Various Configurations with High-Power PIU(s) Diversity Mode Number of Sectors (AU-IDUs) Number of ODUs Number of Power Feeders Second Order Diversity 12 12 16 24 Fourth Order Diversity 1.2.7 Power Interface Unit (PIU) The single Euro PIU module is the interface between the Base Station site's DC power source and the Base Station chassis PSUs and external AU ODUs, which receive power via the AU-IDUs. The PIU filters and stabilizes the Base Station input power and protects the system from power problems such as over voltage, surge pulses, reverse polarity connection and short circuits. It also filters high frequency interference (radiated emissions) and low frequency interference (conducted emissions) to the external power source. Each Base Station chassis contains two slots for an optional 1+1 PIU redundancy. One PIU is sufficient to support a fully populated chassis. Two PIU modules provide redundant power feeding (two input sources) while avoiding current flow between the two input sources. BreezeMAX Modular Base Station System Manual 11 Chapter 1 - System Description The regular PIU can support a total current of up to 35 A (@40.5 VDC), enabling support of a Base Station with up to 8 High-Power AU-ODUs (4 sectors using second order diversity). For configurations with a higher number of ODUs it is necessary to use Power Feeder(s). The High-Power PIU can support a total current of up to 58 A, enabling support of up to 20 High-Power AU-ODUs. For configurations with a higher number of ODUs (6 sectors with fourth order diversity) it is necessary to use a Power Feeder. 1.2.8 Power Supply Unit (PSU) The single Euro PSU module is a 48 VDC power supply unit. Each Base Station chassis can contain up to four PSU modules providing N+1 redundancy configurations. Table 1-3 displays the number of PSU modules (excluding redundant units) required for various Base Station configurations without NPU redundancy (one NPU): Table 1-3: PSU Requirements, Configurations with one NPU (excluding PSU redundancy) 1.2.9 Number of AU-IDUs Minimum Required Number of PSUs 1-2 3-4 5-6 Air Ventilation Unit (AVU) The 2U high AVU includes a 1U high integral chamber for inlet airflow and a 1U high fan tray with an internal alarm module. To support high availability Base Station, the fan tray includes 10 brush-less fans, where 9 fans are sufficient for cooling a fully loaded chassis. A failure in any of the fans is indicated by both the front panel LEDs and a trap that is sent to the management system. To further support high availability, the chassis may operate with the hot-swappable fan tray extracted from it for a period of time sufficient for replacing it (up 10 minutes). 1.2.10 GPS GPS is used to synchronize the air link frames of Intra-site and Inter-site located sectors to ensure that in all sectors the air frame will start at the same time, and 12 System Description Base Station Equipment that all sectors will switch from transmit (downlink) to receive (uplink) at the same time. This synchronization is necessary to prevent Intra-site and Inter-site sectors interference and saturation (assuming that all sectors are operating with the same frame size and with the same DL/UL ratio). The GPS clock required is 1PPS with accuracy of 10-11 and maximum jitter of 100ns. These GPS clock requirements can be reached by indoor or outdoor installed GPS unit when it is synchronized to at least 4 satellites. Two types of GPS Receivers are available from Alvarion: Indoor GPS Receiver (with an outdoor antenna) Outdoor GPS Receiver A GPS Adapter is required to provide the interface between the NPU and the GPS Receiver. 1.2.10.1 Indoor GPS Receiver The Indoor GPS Receiver comprises a GPS receiver integrated with a stable OCXO oscillator, within a unit designed for mounting in a standard 19 inch rack. An up to 50 meter coaxial cable connects it to an active antenna. The indoor installed GPS system is able to provide up to 40 hours of clock holdover with a maximal drift of 50 microseconds when the GPS system losses satellites synchronization. The Indoor GPS provides 1PPS at TTL levels and the control channel is driven by an RS-232 serial interface. The unit is powered directly from a -48 VDC power source. 1.2.10.2 Outdoor GPS Receiver The all-outdoor GPS Receiver is a pole mountable GPS receiver and antenna in a single environmentally protected enclosure. The Outdoor GPS Receiver is powered by a 12 VDC power source, supplied to it by the NPU via the GPS Adapter. The RS-422 interface allows installation at distances up to 100m. 1.2.10.3 GPS Adapter Unit The GPS Adapter connects the different GPS units to the NPU, adapting the different interfaces. Future versions may include an internal GPS module that will allow an all-in-one low-cost solution. A future optional addition of OCXO in the GPS Adapter box may provide an improved hold over solution when the GPS is not synchronized. The GPS Adapter is powered by 12 VDC supplied by the NPU. The GPS Adapter is installed in a 1U high panel (the same panel that is used for the ODU Power Feeders). BreezeMAX Modular Base Station System Manual 13 Chapter 1 - System Description 1.3 Networking Equipment The Base Station is connected to the backbone through standard data communication and telecommunication equipment. The NPU aggregates the traffic from all AUs, connecting to the backbone through a 100/1000 Base-T port. The point-to-point link from the Base Station to the backbone can be either wired or wireless. Alvarion offers the DUET 6004, a V5.2 to SIP Access Gateway connecting a Class 5 switch over V5.2 to its’ Voice Gateways. 1.3.1 DUET 6004 Access Gateway The DUET 6004 is a carrier-grade V5.2 to SIP gateway, connecting a Class 5 switch over V5.2 to Alvarion's SIP stand alone Voice Gateways (VG-1D1V and VF-1D2V) or Voice Gateway IDUs (IDU-1D1V and IDU-1D2V). A Local Exchange (LE) with the DUET 6004 support basic and advanced telephony services as CLASS services, IN services and others. The DUET can be either collocated with the BreezeMAX Base Station or installed at the LE premises concentrating the traffic of many Base Stations. The LE switch provides the call processing, billing and administrative functions, while the DUET provides the signaling translation and media conversion: Signaling Translation: converting the V5.2 signaling into SIP commands and vice versa. Media Conversion: converting media formats such as PCM to G.729A and others. It also provides additional media related services such as Echo Canceling and others. Outbound SIP Proxy: The DUET operates as outbound SIP proxy for the Voice Gateways. All outbound calls from the user agents are sent to the DUET. Note that the DUET does not support SIP-to-SIP calls and all calls are always passed to the switch via the V5.2 interface. Registration: Processing registration requests of the SIP Voice Gateways connected to the BreezeMAX CPE. The DUET complies with the V5.2 interface standard second edition and the SIP RFC 3261, "SIP: Session Initiation Protocol", making it a certified means to 14 System Description Management Systems provide telephony and advanced services over an IP network. It supports voice band data transmission of FAX G.3 (over G.711 or T.38), pay phone signaling (Tax and reverse polarity), CLI, as well as other services that are hook flash based (call waiting, hold, call forward, etc.). 1.4 Management Systems The end-to-end IP-based architecture of the system enables full management of all components, using standard management tools. An SNMP agent in the NPU implements standard and proprietary MIBs for remote setting of operational modes and parameters of the Base Station equipment as well as the Subscriber Units served by it. Security features incorporated in BreezeMAX units restrict the access for management purposes. In addition, the Ethernet WAN can be used to connect to other Operation Support Systems including servers, Customer Care systems and AAA (Authentication, Authorization and Admission) tools. 1.4.1 AlvariSTAR™ AlvariSTAR is a comprehensive Carrier-Class network management system for Alvarion's Broadband Wireless Access products-based Networks. AlvariSTAR is designed for today's most advanced Service Providers' Network Operation Centers (NOCs), providing the network Operation, Administration and Maintenance (OA&M) staff and managers with all the network surveillance, monitoring and configuration capabilities that they require in order to effectively manage the BWA network while keeping the resources and expenses at a minimum. AlvariSTAR is designed to offer the network's OA&M staff with a unified, scalable and distributable network management system. AlvariSTAR system uses a distributed client-server architecture, which provides the service provider with a robust, scalable and fully redundant network management system in which all single points of failure can be avoided. AlvariSTAR provides the following BWA network management functionality: Device Discovery Device Inventory Topology BreezeMAX Modular Base Station System Manual 15 Chapter 1 - System Description Fault Management Configuration Management Service Management Data Collection Performance Monitoring Device embedded software upgrade Security Management Northbound interface to other Network Management Systems. Embedded with the entire knowledge base of BWA network operations, AlvariSTAR is a unique state-of-the-art power multiplier in the hands of the service provider that enables the provisioning of satisfied customers. AlvariSTAR dramatically extends the abilities of the service provider to provide a rich portfolio of services and to support rapid customer base expansion. 1.4.2 AlvariCRAFT™ Alvarion's AlvariCRAFT is an SNMP (Simple Network Management Protocol) application designed for on-line management of BreezeMAX system components. This utility simplifies the installation and maintenance of small size installations by easily enabling the change of settings or firmware upgrade for one Base Station at a time, including the managed device's components and associated SUs. AlvariCRAFT allows accessing a wide array of monitoring and configuration options, including: Device Manager for the selected Base Station, including it's NPU, AUs and SUs Selected unit configuration modification Local Service Profiles verification and modification Local Service Provisioning Firmware upgrade for the NPU, AUs and SUs 16 System Description Management Systems On-line performance data monitoring Export of configuration details to a CSV file Support for Telnet cut-through to the Base Station and http cut-through to Gateways behind connected SUs. 1.4.3 BreezeMAX Service Manager BreezeMAX Service Manager provides centralized management of user authentication and authorization using the industry standard RADIUS protocol. The BreezeMAX Service Manager receives from the NPU (operating as a NAS) the authentication details (User Name and Password) upon network entry of a new CPE, and respond (if authentication if verified by matching details in the database) by sending properties of the Services that should be granted to the user. BreezeMAX Modular Base Station System Manual 17 Chapter 1 - System Description 1.5 Specifications 1.5.1 Radio Table 1-4: Radio Specifications Item Description Frequency Unit/Band Frequency (MHz) AU-ODU-HP-2.3 2300 - 2360 AU-ODU-HP-2.3-WCS 2305 - 2317, 2348 - 2360 (incliudes WCS filter) AU-ODU-HP-2.5A 2496 - 2602 AU-ODU-HP-2.5B 2590 - 2690 AU-ODU-HP-TDD-3.3a 3300-3355 AU-ODU-HP-TDD-3.3b 3345-3400 AU-ODU-HP-TDD-3.4a 3399.5 - 3455 AU-ODU-HP-TDD-3.4b 3445 - 3500 AU-ODU-HP-TDD-3.5a 3500 - 3555 AU-ODU-HP-TDD-3.5b 3545 - 3600 AU-ODU-TDD-3.6b 3650-3675 Operation Mode TDD Channel Bandwidth 3.5 MHz 5 MHz Central Frequency Resolution 0.125 MHz (actual configurable frequencies depend on the local radio regulations and allocated spectrum) Antenna Port (AU-ODU) N-Type, 50 Ohm Max. Input Power (at AU-ODU antenna port) -60 dBm before saturation, -8 dBm before damage Output Power (at AU-ODU antenna port) 2.x GHz: 36 dBm +/-1 dB maximum Power control range: 6 dB, in 1 dB steps 3.3 GHz 32 dBm +/-1 dB maximum Power control range: 10 dB, in 1 dB range 3.5 GHz 34 dBm +/-1 dB maximum Power control range: 10 dB, in 1 dB range 3.6 GHz 18 22 dBm +/-1 dB maximum System Description Specifications Table 1-4: Radio Specifications Item Description Modulation OFDM in the Downlink, OFDMA-16 in the Uplink (N x SUs per Symbol, N=1-16), BPSK, QPSK, QAM16, QAM64 FEC Convolutional Coding: 1/2, 2/3, 3/4 Typical Sensitivity (BER=1E-6) Modulation & Coding Minimum SNR (dB) Sensitivity (dBm) @ 3.5 MHz BW Sensitivity (dBm) @ 5 MHz BW BPSK 1/2 2.5 -98.5 -97 QPSK 1/2 5.9 -94.5 -93 QPSK 3/4 8.6 -91.5 -90 QAM16 1/2 11.4 -87.5 -86 QAM16 3/4 14.8 -84.5 -83 QAM64 2/3 20 -80.5 -79 QAM64 3/4 20.9 -78.5 -77 BreezeMAX Modular Base Station System Manual 19 Chapter 1 - System Description 1.5.2 Base Station 2.X GHz Antennas (Optional) Table 1-5: Base Station 2.X GHz Antennas, Electrical Specifications Item Description BS ANT 60/2.X V 16.5 dBi minimum in the 2.3-2.7 GHz band, 60°AZ x 7°EL sector antenna, vertical polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 90/2.X V 15.5 dBi minimum in the 2.3-2.7 GHz band, 90°AZ x 7°EL sector antenna, vertical polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 120/2.X V 14 dBi minimum in the 2.3-2.7 GHz band, 120°AZ x 7°EL sector antenna, vertical polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 65/2.X DP 2 x 17 dBi minimum in the 2.3-2.7 GHz band, 65°AZ x 7°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 90/2.X DP 2 x 15.5 dBi minimum in the 2.3-2.7 GHz band, 90°AZ x 8°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 120/2.X DP 2 x 13 dBi minimum in the 2.3-2.7 GHz band, 120°AZ x 8°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS 20 System Description Specifications 1.5.3 Base Station 3.x GHz Antennas (Optional) Table 1-6: Base Station 3.x GHz Antennas, Electrical Specifications Item Description BS ANT 60V/3.3-3.8 16.5 dBi minimum in the 3.3-3.8 GHz band, 60° AZ x 7° EL, vertical polarization, compliant with ESTI EN 302 326-3 V1.2.1 (2007-01). BS ANT 90V/3.3-3.8 14.5 dBi typical in the 3.3-3.8 GHz band, 90° AZ x 9° EL, vertical polarization, compliant with ESTI EN 302 326-3 V1.2.1 (2007-01) BS ANT 120V/3.3-3.8 13 dBi typical in the 3.3-3.7 GHz band, 120° AZ x 6.7° EL, vertical polarization, compliant with ESTI EN 302 326-3 V1.2.1 (2007-01). BS ANT 60/3.5H 16 dBi typical in the 3.4-3.6 GHz band, 60° AZ x 9° EL, horizontal polarization, compliant with EN 302 326-3 V1.2.1 (2007-01) BS ANT 90/3.5H 14 dBi typical in the 3.4-3.6 GHz band, 90° AZ x 8° EL, horizontal polarization, compliant with EN 302 326-3 V1.2.1 (2007-01) BS ANT 65/3.5 DP 2 x 16.5 dBi minimum in the 3.3-3.8 GHz band, 65°AZ x 7°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 90/3.5 DP 2 x 15.5 dBi minimum in the 3.3-3.8 GHz band, 90°AZ x 7°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS BS ANT 120/3.5DP 2 x 13 dBi minimum in the 3.3-3.8 GHz band, 120°AZ x 7°EL sector antenna, dual slant +/- 45° polarization, compliance with ETSI EN 302 326-3 V1.2.1 (2007-01) and RoHS Omni ANT 3.4-3.6 10 dBi typical in the 3.4-3.6 GHz band, 360° AZ x 9° EL, vertical polarization BreezeMAX Modular Base Station System Manual 21 Chapter 1 - System Description 1.5.4 AU-IDU to AU-ODU Communication Table 1-7: AU-IDU to AU-ODU Communication Item Description IF Frequency Tx: 240 MHz Rx: 140 MHz Ref Synchronization Frequency 64 MHz Bi-Directional Control Frequency 14 MHz IF cable Impedance 50 Ohm Maximum IF cable Attenuation 10 dB @ 240 MHz 7.5 dB @ 140 MHz 8 dB @ 64 MHz Minimum IF cable Shielding Effectiveness 90 dB in the 10-300 MHz band Maximum IF cable Return Loss 20 dB in the 10-300 MHz band Maximum IF cable DC Resistance 1.5 Ohm 1.5.5 Data Communication (Ethernet Ports) Table 1-8: Data Communication (Ethernet Ports) Item Description Standard Compliance IEEE 802.3 CSMA/CD Maximum Packet Size 1550 Bytes (including 4 CRC bytes and 4 VLAN tag bytes) Speed Data Port 100/1000 Mbps, Full Duplex Management Port 10/100 Mbps, Half/Full Duplex with Auto Negotiation 22 System Description Specifications 1.5.6 Configuration and Management Table 1-9: Configuration and Management Item Description Out Of Band (OOB) Management Telnet via Management port SNMP via Management port Monitor port In Band (IB) Management via Data Port SNMP Telnet SNMP Agents SNMP ver 1 client MIB II (RFC 1213), Private BreezeMAX MIBs Authentication and Authorization RADIUS Software upgrade Using TFTP Configuration upload/download Using TFTP 1.5.7 Environmental Table 1-10: Environmental Specifications Type Unit Details Operating temperature Outdoor units AU-ODU-HP-2.3-WCS: -52°C to 55°C All other ODUs: -40°C to 55°C Outdoor GPS Receiver: -40°C to 85°C Outdoor Antenna of Indoor GPS Receiver :-40°C to 70°C Operating humidity Indoor equipment 0°C to 40°C Outdoor units 5%-95% non condensing, Weather protected Indoor equipment 5%-95% non condensing BreezeMAX Modular Base Station System Manual 23 Chapter 1 - System Description 1.5.8 Standards Compliance, General Table 1-11: Standards Compliance, General Type Standard EMC ETSI EN 301 489-1/4 ETSI EN 300-385 EN 60950-1 Safety UL 60 950-1 Environmental ETS 300 019: Part 2-1 T 1.2 & part 2-2 T 2.3 for indoor & outdoor Part 2-3 T 3.2 for indoor Part 2-4 T 4.1E for outdoor ETSI EN 301 753 V.1.1.1 Radio ETSI EN 301 021 V.1.6.1 ETSI EN 302 326 FCC 04-135 FCC 27.53, FCC P.15, FCC P.90 24 System Description Specifications 1.5.9 Services Table 1-12: Services Item Description Max number of Services per BST 4,095 (one or several services may be defined per subscriber, one or more subscribers can be supported per SU) Max number of Service Profiles per BST 1,024 Max number of Forwarding Rules per BST 255 Max number of Priority Classifiers per BST 255 Max number of QoS Profiles per BST 255 Max number of Subscribers per BST 1,024 (applicable only for permanent SUs) Min number of data connections per Service 2 (1 uplink, 1 downlink) Max number of data connections per Service 8 (4 uplink, 4 downlink) Max number of data connections per SU 32 per direction Max number of data connections per AU 3999 - 3 x number of SUs (3 connections are reserved for each SU) Max number of SUs per AU 510 Max number of AUs per BST 7 (maximum 6 concurrently active AUs) Max number of MAC addresses in Bridging Table BST: 6,000 SU: 512 (Aging time is configurable. The default is 3 minutes for SU, 10 minutes for NPU) Max number of VLANs per Service 16 Max number of VLANs per SU 16 Max number of VLANs (VPL IDs) per BST 1,024 Max number of concurrent voice calls per Voice/L2 Service (with DRAP) 50 Max number of concurrent voice calls per AU (with DRAP) 300 BreezeMAX Modular Base Station System Manual 25 Chapter 1 - System Description 1.5.10 Physical and Electrical 1.5.10.1 Mechanical Specifications, Base station Equipment Table 1-13: Mechanical Specifications, Base Station Equipment Unit Dimensions (cm) Weight (kg) BST-SH 8U ETSI type shelf, 8U x 43.19 x 24 6.9 (excluding AVU) Regular PIU 3U x 5HP x 16 0.35 High-Power PIU 3U x 5HP x 16 0.45 PSU 3U x 8HP x 16 0.7 NPU 6U x 7HP x 16 0.7 AU-IDU-4CH 6U x 7HP x 16 0.6 AU-ODU-HP (except 2.3 GHz WCS models) 32.9 x 15.7 x 16.9.9 6.1 AU-ODU-HP (2.3 GHz WCS models) 32.9 x 15.7 x 20.9 8.6 AVU 2U x 84HP x 16 1.7 Power Feeder panel 1U ETSI type panel 0.14 Power Feeder Module 15.7 x 14.6 x 3.17 0.6 GPS Adapter 15.7 x 14.6 x 3.17 0.4 Outdoor GPS Receiver Tubular enclosure, 15.5 D x 12.7 H 0.363 Indoor GPS Receiver 1U x 30.8 x 21.3 1.4 * 1U=44.45 mm (1.75"), 1HP=5.08 mm (0.2") 26 System Description Specifications 1.5.10.2 Electrical Specifications, Base station Equipment Table 1-14: Electrical Specifications, Base Station Equipment Unit Details Power Source -40.5 to -60 VDC Regular PIU Power Consumption: 16W maximum (active PIU) Maximum Supplied Current: 35 A High-Power PIU Power Consumption: 35W maximum (active PIU) Maximum Supplied Current: 58 A PSU 200W maximum output power Efficiency: 80% minimum NPU 65W maximum, 44W typical, excluding power that may be required for GPS Adapter (1.2W maximum) and Outdoor GPS Receiver (6W maximum) AU-IDU 46W maximum, 39W typical AU-ODU-HP-2.x GHz Tx (DL) 89W maximum, 75W typical Rx (UL) 15W maximum, 9W typical Tx (DL) 90W maximum, 62W typical Rx (UL) 20W maximum, 14W typical AU-ODU-HP-3.x GHz AVU 24W maximum, 23W typical ODU Power Feeder Power Source: -40.5 to -60 VDC Power Dissipation: 2W per channel GPS Adapter 12 VDC from the NPU, 1.2W maximum Indoor GPS Receiver Power Source: -36 to -72 VDC Power Dissipation: 20W maximum, 12W typical Outdoor GPS Receiver 12 VDC from the NPU via the GPS Adapter, 6W maximum BreezeMAX Modular Base Station System Manual 27 Chapter 1 - System Description 1.5.10.3 Connectors, Base station Equipment Table 1-15: Connectors, Base Station Equipment Unit Connector Description Regular PIU -48V 3 pin/40A D-Type male. Amphenol P/N 717TWA3W3PHP2V4RRM6 (or equivalent) High-Power PIU -48V 5 pin/40A D-Type male. Harting P/N TB09693009044 (or equivalent) NPU DATA 100/1000Base-T (RJ-45) with 2 embedded LEDs. Cable connection to a PC: Crossed Cable connection to a hub: Straight MGMT 10/100Base-T (RJ-45) with 2 embedded LEDs. Cable connection to a PC: Crossed Cable connection to a hub: Straight GPS/SYNC IN 15-pin micro D-Type jack GPS/SYNC OUT 15-pin micro D-Type jack ALRM IN 9-pin micro D-Type jack ALRM OUT 9-pin micro D-Type jack MON 3-pin low profile jack AU-IDU ODU 1 - ODU 4 4 x TNC jack, lightning protected AU-ODU-HP IF TNC jack, lightning protected ANT N-Type jack, 50 Ohm, lightning protected ODU 1 -4 4 x TNC jack, lightning protected IDU 1-4 4 x TNC jack, lightning protected Power 3 pin/20A D-Type plug, Amphenol P/N BASE STATION INTERFACE 15-pin D-Type jack IDU GPS CMD 9-pin D-Type jack IDU GPS 1PPS IN BNC jack ODU GPS RJ-45 jack ODU Power Feeder GPS Adapter 28 System Description Specifications Table 1-15: Connectors, Base Station Equipment Unit Connector Description Indoor GPS Receiver POWER 4 pins power plug TIME OF DAY CHANNEL 9-pin D-Type jack COMMAND CHANNEL 9-pin D-Type jack 2.048MHz BNC jack 1PPS BNC jack ANTENNA TNC jack Outdoor GPS Receiver 1.5.10.4 12-pin round plug Base Station 2.X GHz Antennas, Mechanical Specifications Table 1-16: Base Station 2.X GHz Antennas, Mechanical Specifications Unit Description Dimensions (cm) Weight (kg) BS ANT 60/2.X V Downtilt Mounting Kit: 2" to 4.5" pole 109.3 x 21.3 x 12.4 5 maximum 109.3 x 21.3 x 12.2 5 maximum 109.3 x 20.5 x 11.9 5 maximum 100 x 12 x 5 2 maximum 100 x 12 x 5 2 maximum 100 x 17 x 9 5 maximum Connector: N-Type female BS ANT 90/2.X V Downtilt Mounting Kit: 2" to 4.5" pole Connector: N-Type female BS ANT 120/2.X V Downtilt Mounting Kit: 2" to 4.5" pole Connector: N-Type female BS ANT 65/2.X DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female BS ANT 90/2.X DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female BS ANT 120/2.X DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female BreezeMAX Modular Base Station System Manual 29 Chapter 1 - System Description 1.5.10.5 Base Station 3.x GHz Antennas, Mechanical Specifications Table 1-17: Base Station 3.x GHz Antennas, Mechanical Specifications Unit Description Dimensions (cm) Weight (kg) BS ANT 60V/3.3-3.8 Mounting kit: 2" to 4" pole 76.6 x 15 x 8.7 2.2 76.6 x 15 x 8.6 2.2 76.6 x 14.4 x 8.3 2.0 50 x 20 x 2.8 60 x 25 x 5.5 85.1 x 16 x 6.1 2 maximum 85.1 x 16 x 6.1 2 maximum 68.8 x 16 x 14.5 2 maximum 67.5 tubular, 8 diameter 0.29 Connector: N-Type female BS ANT 90V/3.3-3.8 Mounting kit: 2" to 4" pole Connector: N-Type female BS ANT 120V/3.3-3.8 Mounting kit: 0.75" to 2" pole Mechanical tilt: 0° to -30°. Connector: N-Type female BS ANT 60/3.5H Mounting kit: 2" to 4" pole Connector: N-Type female BS ANT 90/3.5H Mounting kit: 2" to 4" pole Connector: N-Type female BS ANT 65/3.5 DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female BS ANT 90/3.5 DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female BS ANT 120/3.5 DP Downtilt Mounting kit: 4 to 12 cm pole Connector: 2 x N-Type female Omni ANT 3.4-3.6 30 Mounting bracket: up to 50 mm pole. Connector: N-Type female System Description 2 Chapter 2 - Installation Guidelines In This Chapter: “Installing the AU-ODU” on page 32 “Installing the Base Station Equipment” on page 41 “Installing the ODU Power Feeder” on page 63 “Installing the GPS Adapter” on page 67 NOTE Refer to the BreezeMAX Base Station Installation Manual for more detailed instructions on installation of the Base Station and its components. Chapter 2 - Installation Guidelines 2.1 Installing the AU-ODU The following sections describe how to install the AU-ODU, including pole mounting the ODU and connecting the cables. For more detailed instructions, refer to the BreezeMAX TDD Base Station Installation & Maintenance Manual. NOTE In sectors with diversity (either second or fourth order diversity), new 2.x GHz AU-ODUs with HC08 revision 137 (HW ready for 10 MHz bandwidth), cannot be connected to the same AU-IDU together with older AU-ODUs with HC08 version 134. All AU-ODUs connected to the same AU-IDU must use the same HC08 version. 2.1.1 AU-ODU Installation Requirements 2.1.1.1 AU-ODU Packing List AU-ODU Pole mounting kit 2.1.1.2 Additional Installation Requirements The following items are also required to install the AU-ODU: IF cable with two TNC connectors* (see Section 2.1.3 for details on IF cable types and length). Antenna* and RF cable* for connecting the antenna to the AU-ODU. Grounding cable with an appropriate termination. Installation tools and materials, including appropriate means (e.g. a 1" to 4" pole) for installing the AU-ODU and antenna. An “H” kit for installation of up to 4 ODUs and 4 antennas that serve a single sector is optionally available*. NOTE Items marked with an asterisk (*) are available from Alvarion. 32 Installation Installing the AU-ODU 2.1.2 Guidelines for Positioning the AU-ODU This section provides key guidelines for selecting the optimal installation locations for the AU-ODU and its antenna. CAUTION ONLY experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities should install outdoor units and antennas. Failure to do so may void the BreezeMAX product warranty and may expose the end user or Service Provider to legal and financial liabilities. Alvarion and its resellers or distributors are not liable for injury, damage or regulation violations associated with the installation of Outdoor Units or antennas. Select the optimal locations for the equipment using the following guidelines: The ODU can be either pole or wall mounted. Its location should enable easy access to the unit for installation and testing. The higher the placement of the antenna, the better the achievable link quality. The antenna should be installed so as to provide coverage to all Subscriber Units within its service area. NOTE The recommended minimum distance between any two antennas in neighboring sectors is 0.5 meters. The minimum distance between any two antenna in the same sector (space diversity configuration) is 1.3 meters. The ODU should be installed as close as possible to the antenna. NOTE An “H” kit for installation of up to 4 ODUs and 4 antennas that serve a single sector is optionally available from Alvarion. Refer to the detailed BreezeMAX TDD Base Station Installation & Maintenance Manual for information on installing the “H” accessory. 2.1.3 IF Cables The AU-ODU is connected to the AU-IDU (or to the ODU Power Feeder) via an IF cable carrying both signals and power. The maximum permitted attenuation of the IF cable at applicable frequencies, its screening effectiveness and its BreezeMAX Modular Base Station System Manual 33 Chapter 2 - Installation Guidelines maximum permitted DC resistance (the sum of the DC resistance of the inner and outer conductors) are provided in the following table. Table 2-1: IF Cables Requirements Item Description Screening Effectiveness 90 dB minimum in the 10-300 MHz band. IF cable Impedance 50 Ohm Maximum IF cable Attenuation 10 dB @ 240 MHz 7.5 dB @ 140 MHz 8 dB @ 64 MHz Maximum IF cable DC Resistance 1.5 Ohm Maximum IF cable Return Loss 20 dB in the 10-300 MHz band To comply with the required screening effectiveness requirement, it is recommended to use double shielded cables. The following table provides details on maximum length for some popular cables. Table 2-2: Maximum IF Cable Length (Double Shielded Cables) 2.1.4 Cable Maximum Length for AU-ODU-HP LMR-195 30 meters LMR-240 60 meters LMR-400 150 meters Pole Mounting the ODU The ODU can be mounted on a 1" to 4" pole using one of the following options: Special clamps and threaded rods are supplied with each unit. There are two pairs of threaded holes on the back of the unit, enabling to use the clamps for mounting the unit on diverse pole diameters. The protrusions with grooves on the top backsides of the unit, and the protrusion on the bottom backside, enable the use of 9/16" wide metal bands (not included with the package) to secure the unit to a pole. 34 Installation Installing the AU-ODU NOTE Install the unit with the bottom panel, which includes the LEDs, facing downward. 2.1.4.1 Pole Mounting the AU-ODU-HP Using Clamps Figure 2-1 illustrates the method of mounting a High Power AU-ODU-HP on a pole, using the clamps and threaded rods. Figure 2-1: AU-ODU-HP Pole Installation Using Special Clamps NOTE There is a groove on one end of the threaded rod. Insert the threaded rods with the grooves pointing outward, as these grooves enable you to use a screwdriver to fasten the rods to the unit. BreezeMAX Modular Base Station System Manual 35 Chapter 2 - Installation Guidelines 2.1.4.2 Pole Mounting the AU-ODU-HP Using Metal Bands Figure 2-2 illustrates the method of mounting a High Power AU-ODU-HP on a pole, using metal bands. Figure 2-2: AU-ODU-HP Pole Installation Using Metal Band 36 Installation Installing the AU-ODU 2.1.5 AU-ODU Figure 2-3: Bottom Panel of the AU-ODU (except 2.3 GHz WCS) Figure 2-4: Bottom Panel of the AU-ODU - 2.3 GHz WCS BreezeMAX Modular Base Station System Manual 37 Chapter 2 - Installation Guidelines CAUTION Do not open the impermeability test screw - you may impair the sealing of the unit against moisture and humidity. Table 2-3: AU-ODU LEDs Name Description Functionality PWR Power indication Off - Power failure Green - Power to ODU is OK, internal 3.3 VDC power supply is OK. ALARM IDU-ODU communication and synthesizer status indication Off - IDU-ODU communication is OK, synthesizer is locked. Red - IDU-ODU communication failure or synthesizer is not locked ETH Not Used Table 2-4: AU-ODU Connectors Name Connector IF TNC jack Connection to the AU-IDU/ODU Power Feeder N-Type jack, 50 Ohm Connection to an external antenna Grounding screw Connection to ground (earth) ANT (GND) Functionality 2.1.6 Connecting the Cables 2.1.6.1 Connecting the Grounding Cable The Grounding screw (marked ) is located on the bottom panel of the outdoor unit. To connect the grounding cable: Connect one end of a grounding cable to the grounding screw and tighten the grounding screw firmly. Connect the other end of the grounding cable to a good ground (earth) connection. 38 Installation Installing the AU-ODU 2.1.6.2 Connecting the Antenna Cable To connect the RF cable: Connect one end of the coaxial RF cable to the RF connector (marked located on the bottom panel of the unit. Connect the other end of the RF cable to the antenna. The RF connectors should be properly sealed to protect against rain and moisture. 2.1.6.3 Connecting the IF Cable To connect the IF cable: Connect one end of the coaxial IF cable to the IF connector on the bottom panel of the unit. Verify that the length of the IF cable is sufficient to reach the AU-IDU/Power Feeder. See IF cable length limitation in Section 2.1.3. The IF cable connector should be properly sealed to protect against rain and moisture. Route the cable to the location selected for the indoor equipment. BreezeMAX Modular Base Station System Manual 39 Chapter 2 - Installation Guidelines 2.2 Installing the Base Station Equipment 2.2.1 BST Installation Requirements 2.2.1.1 Packing List Base Station Chassis: BMAX-BST-SH Base Station Chassis BMAX-BST-AVU Air Ventilation Unit (installed) Cables Tray kit BMAX-BST-PIU (1 or 2 per chassis) Power Interface Unit(s), or BMAX-4M-BST-PIU (1 or 2 per chassis) High-Power Interface Unit(s). A suitable DC power cable is supplied with each PIU. BMAX-BST-PSU (up to 4 per chassis) Power Supply Unit(s) BMAX-BST-TDD-NPU Network Processing Unit and Monitor cable BMAX-BST-AU-IDU-4CH (up to 6 per chassis) Access Unit Indoor Unit(s) 2.2.1.2 Additional Installation Requirements The following items are also required to install the BST: Ethernet cable (straight) for connecting the NPU to a Hub/Switch. NOTE The maximum length of the Ethernet cable is 100m when operating at 100 Mbps and 70m when operating at 1 Gbps. A grounding cable with appropriate terminations for connecting the chassis to the rack or another ground (earth) connection. For installation in a 21" ETSI rack: Two 21" ETSI rack adapters A portable PC for configuring parameters using the Monitor cable (supplied with the NPU) 40 Installation Installing the Base Station Equipment Other installation tools and materials 2.2.2 BMAX-BST-SH Chassis Slot Assignments The Base Station chassis comprises 6 3U high slots and 9 6U high slots, as shown in Figure 2-5. Cable Tray Air Ventillation Unit Figure 2-5: BMAX-BST-SH Chassis Slot Assignments The Cable Tray (the installation kit is supplied with the chassis) should be installed on the top of the chassis front to enable convenient routing of cables connecting to power source(s), outdoor unit(s) and other equipment. To enable power source and/or Power Interface Unit 1+1 redundancy, two PIU modules can be installed in the designated slots. If a single PIU module is used, it can be inserted into either one of the two available slots. The number of installed PSU modules depends on the specific configuration (number of AUs) and NPU redundancy scheme (refer to Table 2-7). If less than 4 PSU modules are used, they can be installed in any of the designated slots. The NPU should be installed in slot number 5 (slot numbers are marked on the Cable Guide). Slot 6 is reserved for a future redundant NPU. Slots 1-4 and 7-9 can hold up to six AU-IDU modules. Unused slots should remain covered until required. BreezeMAX Modular Base Station System Manual 41 Chapter 2 - Installation Guidelines 2.2.3 Power Requirements Use the following table to calculate worst-case power source requirements for the Base Station equipment: Table 2-5: Power Requirements, Base Station Equipment Unit Details Power Source -40.5 to -60 VDC Regular PIU Power Consumption: 16W maximum (active PIU) Maximum Supplied Current: 35 A High-Power PIU Power Consumption: 35W maximum (active PIU) Maximum Supplied Current: 58 A PSU 200W max output power Efficiency: 80% minimum NPU 65W maximum, excluding power required for GPS Adapter (1.2W maximum) and Outdoor GPS Receiver (6W maximum) AU-IDU-4CH 46W maximum AU-ODU-HP-2.x GHz (from PIU or Power Feeder) Tx (DL): 89W maximum AU-ODU-HP-3.x GHz (from PIU or Power Feeder) Tx (DL): 90W maximum AVU 24W maximum Power Feeder 2W per Channel GPS Adapter (from NPU) 1.2W maximum Indoor GPS Receiver (directly form power source) 20W maximum Outdoor GPS Receiver (from NPU via GPS Adapter) 6W maximum Rx (UL): 15W maximum Rx (UL): 20W maximum NOTE The PSU(s) do not supply power to the AU-ODUs. Up to 8 AU-ODUs can be powered directly from the power source via the regular PIU and the back plane. The new High-Power PIU can support up to 20 AU-ODUs. Additional AU-ODUs are powered from ODU Power Feeders. 42 Installation Installing the Base Station Equipment Example: A full 2.x GHz Base Station operating with DL-UL ratio of 60-40, with regular PIU(s), 6 AU-IDUs, 24 ODUs (8 ODUs are powered via the AU-IDUs, 16 ODUs are powered by 4 Power Feeders), a GPS Adapter and an Outdoor GPS Receiver. Power Consumption of the Base Station, including GPS Adapter and Outdoor GPS Receiver, excluding the ODUs: 16(PIU) + [65(NPU) + 1.2(GPS Adapter) +6(Outdoor GPS Receiver) +24(AVU) +6*46(IDU)] / 0.8(PSU Efficiency)=481W. Excluding the PIU(s), the total power that should be supplied by PSUs is 465W. Since each PSU can support a maximum of 200W, we need at least 3 PSUs. A fourth PSU will support a 3+1 redundancy. When calculating the power requirements associated with the ODUs, we should distinguish between the peak power consumption (maximum current) and the average power consumption (taking into account Tx/Rx ratio) that affect the requirements from a backup power source. For a 2.x GHz system, the peak power consumption of the 24 ODUs, including the power required for Power Feeders (20 channels), is 24*89 + 16*2 = 2168W. Thus, the total peak power of the system under worst conditions is 481 + 2168 = 2649W. The average power consumption of the 24 ODUs, assuming DL-UL (Tx/Rx) ratio of 60-40, is 24*(89*0.60 + 15*0.40) + 16*2 = 1459W. Thus, the average power consumption of the system under worst case conditions is 481 + 1459 = 1940W. 2.2.4 HOT SWAP Support The NPU, AU-IDU and PIU modules includes a blue HOT SWAP LED and a micro-switch in the injector/ejector handle to support hot-swap control. After releasing the ejector's button, the HOT SWAP LED should turn on, indicating that power to/from the back-panel is disconnected and the module can be removed safely. For more details refer to Section 2.2.9. 2.2.5 Power Interface Unit (PIU) The single Euro PIU module is the interface between the Base Station site's DC power source and the Base Station Chassis Power Supply Units and external ODUs, which receive power via the IDUs. The PIU filters and stabilizes the Base Station input power and protects the system from power problems such as over voltage, surge pulses, reverse polarity connection and short circuits. It also filters high frequency interference (radiated emissions) and low frequency interference (conducted emissions) to the external power source. Each Base Station chassis contains two slots for an optional 1+1 BreezeMAX Modular Base Station System Manual 43 Chapter 2 - Installation Guidelines PIU redundancy. One PIU is sufficient to support a fully populated chassis. Two PIU modules provide redundant power feeding (two input sources) while avoiding current flow between the two input sources. Figure 2-6: Regular (35A) PIU Module Front Panel 44 Installation Installing the Base Station Equipment Figure 2-7: High-Power (58A) PIU Module Front Panel NOTE The HOT SWAP blue LED does not exist in first generation PIUs. CAUTION When replacing a PIU, disconnect power from the PIU module before inserting/ejecting it to/from the chassis. If the PIU is with HOT SWAP LED, click on the handles and wait for the HOT SWAP LED to turn on before disconnecting the power. After power is disconnected,disconnect the power cable to avoid irreversible damage due to potential excessively high transient current. Connect power to the PIU only after it is fully inserted into the chassis. BreezeMAX Modular Base Station System Manual 45 Chapter 2 - Installation Guidelines Table 2-6: PIU LEDs PWR and MASTER/ACT LEDs PIU Status PWR MASTER/ ACT Off Off Chassis is not connected to power Red Off Power input is out of range or PIU card is damaged. Chassis is powered by the redundant PIU Red Green Power input is out of range or PIU card is damaged. Chassis is powered by the PIU Green Off Power to PIU is OK. PIU is in redundant mode and the chassis is powered from the other PIU Green Green Power to PIU is OK. The chassis is powered from the PIU. HOT SWAP LED Off: Power from the module to the chassis is not disconnected, the PIU is not ready for removal Blue: Power from the module to the chassis can be disconnected and the PIU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. 2.2.5.1 Preparing a Power Cable for the regular (35A) PIU A 2.5m DC power cable is supplied with each chassis. Additional DC cables can be ordered from Alvarion. If necessary, use the following instruction to prepare a DC cable. To prepare the power cable: Use a cable capable of supporting a current of at least 40A. Use a cable with 2 x 8AWG (or thicker) wires for the power plus an additional 8AWG to 20AWG ground wire. The matching power connector to be used is Amphenol D-type power P/N 177TWA/3W3/SP3Y with high power socket contacts P/N 17DM53744-1. Connect the cable to the power connector as follows: Pin 1 (RTN): Red (8 AWG min wire) Pin 2 (-48V): Black (8 AWG min wire) Pin 3 ( 46 ): Ground (shield) (8AWG-20AWG wire) Installation Installing the Base Station Equipment 2.2.5.2 Attach suitable terminal rings to the side that connects to the power source. Preparing a Power Cable for the High-Power (58A) PIU A 2.5m DC power cable is supplied with each chassis. Additional DC cables can be ordered from Alvarion. If necessary, use the following instruction to prepare a DC cable. To prepare the power cable: For a cable length up to 2.5m use a cable with 4 x 10AWG (or thicker) wires for the power plus and an additional 10AWG (or tghicker) ground wire. For a longer cable (up to 10m), use a cable with 4 x 8AWG (or thicker) wires for the power plus and an additional 10AWG (or tghicker) ground wire. The matching power connector to be used is D-SUB 5W5S Female with power pins 40A. Connect the cable to the power connector as follows: Pin 1 (RTN): Red (10/8 AWG min wire) Pin 2 (-48V): Black (10/8 AWG min wire) Pin 3 ( ): Ground (shield), Green/Yellow (10AWG min wire) Pin 4 (-48V): Black (10/8 AWG min wire) Pin 1 (RTN): Red (10/8 AWG min wire) Attach suitable terminal rings to the side that connects to the power source. CAUTION It is strongly recommended to always use the power cables available from Alvarion. Due to the high current that should be supported by the cable, good workmanship in preparing it is essential. 2.2.6 Power Supply Unit (PSU) The single Euro PSU module is a 48 VDC power supply unit. Each Base Station chassis can contain up to four PSU modules providing N+1 redundancy configurations. The following table displays the number of PSU modules (excluding redundant units) required for various Base Station configurations: BreezeMAX Modular Base Station System Manual 47 Chapter 2 - Installation Guidelines Table 2-7: PSU Requirements, Configurations with one NPU (excluding PSU redundancy) Number of AU-IDUs Minimum Required Number of PSUs 1-2 3-4 5 -6 NOTE The PSU(s) do not supply power to the AU-ODUs. Up to 6 AU-ODUs can be powered directly from the power source via the PIU and the back plane. Additional AU-ODUs are powered from ODU Power Feeders. Figure 2-8: PSU Module Front Panel 48 Installation Installing the Base Station Equipment Table 2-8: PSU LEDs LED Status Description PWR ALRM Off Off No power or fatal damage Off Red Power input is out of range or PSU is damaged or PSU is inhibited by NPU Green Off Power is OK and PSU operates properly BreezeMAX Modular Base Station System Manual 49 Chapter 2 - Installation Guidelines 2.2.7 Access Unit Indoor Module (AU-IDU) The double Euro Access Unit IDU module contains the wireless MAC and modem and is responsible for the wireless network connection establishment and for bandwidth management. Each AU-IDU includes four PHY channels that can connect to AU-ODUs. Figure 2-9: AU-IDU Module Front Panel 50 Installation Installing the Base Station Equipment Table 2-9: AU-IDU LEDs Name Description Functionality PWR Power indication Off - AU-IDU is not powered Red - AU-IDU power supply failed (low power) Green - AU-IDU power is OK ALRM Alarm indication Off - AU-IDU is OK Red - AU-IDU failure WLINK Wireless link status indication Off - No SU is associated Green - At least one SU is associated WACT IDU transmission indication Off - No IDU transmission Green - IDU transmission OK SP Spare Not Used IP IP activity indication Off - No downlink (AU to SU) IP activity Green (blinking) - Downlink (AU to SU) IP activity ODU1 - ODU4 PWR IDU to ODU Power Indication Off - No IDU to ODU power output Red - IDU to ODU power output failed Green - IDU to ODU power output OK ODU1 -ODU4 ALRM IDU to ODU communication status Off - IDU-ODU communication OK Red - IDU-ODU communication failure HOT SWAP IDU readiness for hot swap removal Off: Power to the module is not disconnected, the AU-IDU is not ready for removal Blue: Power to the module can be disconnected and the AU-IDU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. BreezeMAX Modular Base Station System Manual 51 Chapter 2 - Installation Guidelines 2.2.8 Network Processing Unit (NPU) The NPU module serves as the central processing unit that manages the base station's components and the SUs served by it. It also aggregates the traffic from the AU modules and transfers it to the IP backbone through a dedicated Gigabit/Fast Ethernet interface. Figure 2-10: NPU Module Front Panel 52 Installation Installing the Base Station Equipment Table 2-10: NPU Connectors Name Connector Functionality DATA 100/1000Base-T (RJ-45) with 2 embedded LEDs. Connection to the backbone. Cable connection to a hub/switch/router: Straight MGMT 10/100Base-T (RJ-45) with 2 embedded LEDs. Connection to OOB management. Cable connection to a PC: Crossed Cable connection to a hub/switch/router: Straight GPS/SYNC IN 15-pin micro D-Type jack Connection to a GPS Adapter (or, in the future, to another NPU) that supplies synchronization signals. GPS/SYNC OUT 15-pin micro D-Type jack Not used currently. Supply of synchronization signals to another unit ALRM-IN 9-pin micro D-Type jack Not used currently. Connections to external alarm indicators (3 alarm inputs, NC or NO) ALRM-OUT 9-pin micro D-Type jack Not used currently. Connections for activation of external devices (4 dry contact pairs) MON 3-pin low profile jack Access for debugging and configuration using the Monitor program Table 2-11: NPU LEDs Name Description Functionality PWR Power indication Off - NPU is not powered Red - NPU power failure Green - NPU power is OK ALRM NPU Alarm indication Off - NPU is OK Red - NPU failure BST ALRM Base Station chassis alarm indication Off - All Base Station modules are OK Red - Failure in one (or more) Base Station modules EXT ALRM External alarm indication Off - No alarms Red - Alarm received via the ALRM IN connector (not applicable in current release) MASTER Master/Slave operation indication Off - Secondary NPU (backup). Not supported in current release. Green - Primary NPU BreezeMAX Modular Base Station System Manual 53 Chapter 2 - Installation Guidelines Table 2-11: NPU LEDs Name Description Functionality GPS/SYNC GPS/IF clock synchronization functionality indication Off - GPS/IF clock synchronization is disabled Green - GPS/IF clock is synchronization enabled HOT SWAP NPU readiness for hot-swap removal Off: Power to the module is not disconnected, the NPU is not ready for removal Blue: Power to the module can be disconnected and the NPU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. 2.2.9 Using the Hot Swap Injector/Ejector Handles The Base Station modules include special handles for high-force insertion/extraction of modules. Each of the 6U high modules (NPU, AU-IDU) includes two such handles, whereas each of the 3U high-modules (PIU, PSU) includes a single handle at the bottom of the front panel. The bottom injector/ejector handle of the NPU and AU-IDU modules includes a micro-switch to support hot-swap control. Second generation PIU modules also support hot-swap, as indicated by the HOT SWAP blue LED. 2.2.9.1 Inserting Modules To insert a module with hot-swap support (NPU, AU-IDU, PIU): Firmly push in the module into its intended slot (slot 5 for the NPU, slot 1-4, 7-9 for AU-IDU). Press the handles up (the upper handle if available)/down (the lower handle) simultaneously until you hear the locking click and the red buttons are released. The blue HOT SWAP LED will briefly turn on (only in AU and NPU), indicating that the module is being powered up. CAUTION In a PIU with HOT SWAP LED, connect power to the PIU only after it is fully inserted into the chassis. Secure the module in place by closing the screws at the top and bottom of the front panel. 54 Installation Installing the Base Station Equipment NOTE If a module is fully inserted without properly locking the handles, it will become operational. However, in this state the hot-swap mechanism is not supported. A warning message (trap) will be sent. To insert a PSU or a PIU without HOT SWAP support: CAUTION In a PIU without HOT SWAP LED, disconnect power from the PIU module before inserting it to the chassis. Firmly push in the module into its intended slot. Press the handle down until you hear the locking click and the red button is released. 2.2.9.2 Secure the module in place by closing the screw at the top of the front panel. Ejecting Modules To eject a module with hot-swap support (NPU, AU-IDU, new PIU): Release the screws at the top and the bottom of the front panel. Press the handles' red button until the handles are unlocked. Wait until the blue HOT SWAP LED turns on, indicationg that the module has been disconnected and can be removed. CAUTION In a PIU with HOT SWAP LED, disconnect power from the PIU module only after it is taken out from the chassis (or after the HOT SWAP LED is turned on). Press the handles down (the upper handle)/up (the lower handle) until the module is unlocked, firmly hold the handles and take the module out of the chassis. To eject a PSU or a PIU without HOT SWAP support: BreezeMAX Modular Base Station System Manual 55 Chapter 2 - Installation Guidelines CAUTION In a PIU without HOT SWAP LED, disconnect power from the PIU module before ejecting it from the chassis. Before disconnecting the power cable from the PIU, the power source must be disconnected to avoid irreversible damage due to a potential excessively high transient current. Release the screw at the top of the front panel. Press the handle's red button until the handle is unlocked. Press the handle up until the module is unlocked, firmly hold the handle and take the module out of the chassis. 2.2.10 Installing the Base Station Chassis and Modules The indoor equipment should be installed as close as possible to the location where the IF cable(s) enters the building. The location of the indoor equipment should take into account its connection to the power source(s) and to the base station networking equipment. To install the Base Station chassis and modules: Attach the Cable Guide to the top panel of the chassis using the screws and washers supplied with the Cable Guide. Install the chassis in a 19" cabinet. For installation in a 21" cabinet, attach suitable ETSI rack adapters to the chassis. To provide a sufficient space for the Cable Guide and to allow air flow for preventing over-heating, leave a free space of at least 1U between the upper covers of the chassis and other units in the cabinet. Connect one end of a grounding cable to the ground terminal located on the rear panel of the chassis and firmly tighten the grounding screw. Connect the opposite end of the grounding cable to a ground connection or to the cabinet, if applicable. Carefully insert the modules into the relevant slots. Secure the modules in their intended locations (refer to Section 2.2.9.1 for instructions on modules' insertion). Place blank covers over all of the unused slots. Connect the DATA port of the NPU to the backbone data equipment (use a straight Ethernet cable to connect to a hub/switch/router). The maximum 56 Installation Installing the Base Station Equipment length of the Ethernet cable is 100m when operating at 100 Mbps and 70m when operating at 1 Gbps. If the MGMT port will be used for remote management, connect it to the appropriate data equipment (use a straight Ethernet cable to connect to a hub/switch/router). The maximum length of the Ethernet cable is 100m. Connect the DC power cable to the power jack of the PIU module. If a redundant PIU is installed, connect a DC power cable also to the second PIU module. Connect the power cord(s) to the -48 VDC power source(s), as follows. Connect the black wire to the 48 VDC contact of the power source. Connect the red wire to the + (Return) contact. Connect the ground wire to the ground. For AU-ODUs that connect directly to AU-IDUs: Connect the IF cable(s) (already connected at the other end to the AU-ODU(s)) to the proper channels (ODU 1 to ODU 4 connectors) of the applicable AU-IDU module(s). If only a single AU-ODU per AU-IDU is used, connect the IF cable(s) to the appropriate ODU-1 connector(s). To avoid transmissions at undesired frequencies, verify that the frequency and bandwidth parameters are properly configured before connecting the IF cables. For AU-ODU that are powered by a Power Feeder: Refer to Section 2.3.3. CAUTION A maximum of eight AU-ODU-HP units can be powered directly from the Base Station (via the ODU connectors of AU-IDUs) using regular (35A) PIU(s). High-Power (58A) PIU(s) can support up to 20 AU-ODU-HP units. Additional AU-ODU-HP units should be powered by ODU Power Feeder(s). BreezeMAX Modular Base Station System Manual 57 Chapter 2 - Installation Guidelines 2.2.11 Air Ventilation Unit (AVU) Figure 2-11: AVU Drawer Front Panel The 2U high, 84 HP wide AVU includes a 1U high integral chamber for inlet airflow and a 1U high fan tray with an internal alarm module. To support a high availability Base Station, the fan tray includes 10 brush-less fans, where 9 fans are sufficient for cooling a fully loaded chassis. To further support high availability, the chassis can operate with the hot-swappable fan tray extracted from it for a period of time sufficient for replacing it (up to 10 minutes). Table 2-12: AVU LEDs LED Status Description PWR ALRM Off Off No 5V power input Red Red 12V power failed Green Red One or more fans have failed Green Off AVU operates properly If the red ALRM LED is on while the PWR LED is green, it indicates a failure of at least one fan. Although the Base Station chassis may continue operating with one failed fan, it is recommended to replace the AVU as soon as possible. 2.2.12 Replacing Base Station Components 2.2.12.1 Replacing an AVU To replace an AVU drawer: Release the 4 screws securing the AVU to the chassis. Using the handle take out the faulty chassis. 58 Installation Installing the Base Station Equipment Insert a new AVU drawer and close the screws. The replacement should be completed in less than 10 minutes. 2.2.12.2 Replacing an NPU To minimize downtime and facilitate fast and easy NPU replacement, it is recommended to maintain an updated copy of the NPU configuration. Refer to Section 4.6.2.6 for details on preparing and uploading a backup file of the NPU configuration. Release the screws at the top and the bottom of the NPU's front panel. Press the handles' red button until the handles are unlocked. Wait until the blue HOT SWAP LED turns on, indicating that the module has been disconnected and can be removed. Press the handles down (the upper handle)/up (the lower handle) until the module is unlocked. Firmly hold the handles and take the module out of the chassis. Disconnect all IF cables connecting the AU-IDUs to the AU-ODUs. This is necessary as the initial configuration of the new NPU is most probably inappropriate. Firmly push the new NPU module into its intended slot (slot 5). Press the handles up (the upper handle)/down (the lower handle) simultaneously until you hear the locking click and the red buttons are released. The blue HOT SWAP LED will briefly turn on, indicating that the module is being powered up. Secure the module in place by closing the screws at the top and bottom of the front panel. Download the backup file using a DOS based TFTP. Use the command: tftp iput . The default IP address of the MGMT port is 10.0.0.1. 10 Use the monitor program to configure the IP parameters (IP address, Subnet Mask, Default Gateway Address) of the MGMT port. These parameters are not affected by the loaded file. 11 Reset the system. 12 Reconnect the IF cables. BreezeMAX Modular Base Station System Manual 59 Chapter 2 - Installation Guidelines 2.2.12.3 Replacing an AU-IDU Disconnect all IF cables connecting the AU-IDUs to AU-ODUs. Release the screws at the top and the bottom of the AU-IDU's front panel. Press the handles' red button until the handles are unlocked. Wait until the blue HOT SWAP LED turns on, indicating that the module has been disconnected and can be removed. Press the handles down (the upper handle)/up (the lower handle) until the module is unlocked. Firmly hold the handles and take the module out of the chassis. Firmly push the new AU module into its intended slot. Press the handles up (the upper handle)/down (the lower handle) simultaneously until you hear the locking click and the red buttons are released. The blue HOT SWAP LED will briefly turn on, indicating that the module is being powered up. Secure the module in place by closing the screws at the top and bottom of the front panel. Reconnect the IF cables. Make sure that each ODU is connected to the appropriate port on the AU. Wait until the AU reboot process is completed. This might take few minutes. 10 Reset the AU. (To perform the reset go to the main menu of the AU, select 2 Unit Control, than select 1 - Reset and confirm the reset. Alternatively, you can press the reset button on the front panel of the AU). 11 Go to the main menu of the AU and verify that the all the parameters and the SW Version are as expected. 12 Verify that the AU operates properly and that the SUs that should be served by it are connected with the AU. 2.2.12.4 Replacing a PIU Release the screws at the top and the bottom of the PIU's front panel. Press the handle’s red button until the handles are unlocked. In units with a HOT SWAP LED, Wait until the blue HOT SWAP LED turns on, indicating that the module has been disconnected and can be removed. 60 Disconnect the power cable from the PIU Installation Installing the Base Station Equipment Press the handle up until the module is unlocked. Firmly hold the handles and take the module out of the chassis. Firmly push the new PIU module into its intended slot. Press the handle down until you hear the locking click and the red buttons are released. Secure the module in place by closing the screws at the top and bottom of the front panel. Connect power to the PIU only after it is fully inserted into the chassis. BreezeMAX Modular Base Station System Manual 61 Chapter 2 - Installation Guidelines 2.3 Installing the ODU Power Feeder 2.3.1 Installation Requirements 2.3.1.1 Packing List A 19” panel (can hold up to three ODU Power Feeder modules). ODU Power Feeder module, including a DC power cable, four 0.5 meter IF cables and four screws. 2.3.1.2 Additional Installation Requirements A grounding cable with appropriate terminations for connecting the unit's ground terminal to the rack or to a ground connection. For installation in a 21" ETSI rack: two 21" ETSI rack adapters Other installation tools and materials 62 Installation Installing the ODU Power Feeder 2.3.2 The ODU Power Feeder The ODU Power Feeder is used to provide power (-48 VDC) to AU-ODU-HP High Power ODUs. It transfers transparently all signals between the AU-IDU and the ODU, while injecting DC power received from an external source. Each ODU Power Feeder unit can serve up to four High Power ODUs. Up to three ODU Power Feeder units can be installed in a 1U high Power Feeder panel. Figure 2-12: ODU Power Feeder Front Panel Figure 2-13: ODU Power Feeder Rear Panel Table 2-13: ODU Power Feeder Connectors Name Connector Functionality IDU 1 - 4 4 x TNC jacks Connection to ODU connectors of AU-IDUs ODU 1 - 4 4 x TNC jacks Connections to IF connectors of AU-ODU-HP units -48V 3-pin D-Type power jack Connection to DC power source Grounding Screw Connection to ground (earth) (GND) BreezeMAX Modular Base Station System Manual 63 Chapter 2 - Installation Guidelines Table 2-14: ODU Power Feeder LEDs Name Description Functionality PWR Input power indication Off - ODU Power Feeder is not powered Green - ODU Power Feeder power is OK ODU PWR 1 - 4 Output power indications Off - AU-ODU-HP is not connected Red - Power output problem (short or overload) Green - AU-ODU-HP is connected and powered 2.3.2.1 Preparing a Power Cable A 2.5m DC power cable is supplied with each ODU Power Feeder module. Additional DC cables can be ordered from Alvarion. If necessary, use the following instruction to prepare a DC cable. To prepare the power cable: Use a cable capable of supporting a current of at least 10A. Use a cable with 2 x 10AWG (or thicker) wires for the power plus an additional 10AWG to 20AWG ground wire. The matching power connector to be used is Amphenol D-type power P/N 177TWA/3W3/SP3Y with high power socket contacts P/N 17DM53744-1. Connect the cable to the power connector as follows: Pin 1 (RTN): Red (10 AWG min wire) Pin 2 (-48V): Black (10 AWG min wire) Pin 3 ( 2.3.3 ): Ground (shield) (10AWG-20AWG wire) Attach suitable terminal rings to the side that connects to the power source. Installing the ODU Power Feeder The ODU Power Feeder should be installed as close as possible to the location where the IF cable(s) enters the building. The location of the ODU Power Feeder should take into account its connection to the power source and to the Base Station equipment. 64 Installation Installing the ODU Power Feeder To install the ODU Power Feeder: The panel is supplied with blank covers. Release the nuts on the rear side of the panels to remove the blank cover(s) you want to replace with ODU Power Feeder module(s). Attach the ODU Power Feeder module(s) to the panel using the four screws supplied with each module. Place the panel with the ODU Power Feeder module(s) on a shelf/desk or install it in a 19" cabinet, next to the Base Station equipment. For installation in a 21" cabinet, attach suitable ETSI rack adapters to the chassis. Connect one end of a grounding cable to the grounding screw located on the rear panel of each ODU Power Feeder module and firmly tighten the grounding screw. Connect the opposite end of the grounding cable(s) to a ground (earth) connection or to the cabinet, if applicable. Connect the IDU connector(s) to the appropriate ODU connector(s) of the AU-IDU(s) using the short (0.5 meter) IF cables supplied with the module. Connect the power cord to the ODU Power Feeder’s DC socket, located on the rear panel. Connect the other end of the power cord to the -48 VDC power source. Connect the IF cable(s), that should already be connected at the other end to the AU-ODU-HP(s), to the appropriate ODU connector(s). To avoid transmissions at undesired frequencies, verify that the frequency and bandwidth parameters are properly configured before connecting the IF cables. BreezeMAX Modular Base Station System Manual 65 Chapter 2 - Installation Guidelines 2.4 Installing the GPS Adapter 2.4.1 Installation Requirements 2.4.1.1 Packing List A 19” panel (can hold also ODU Power Feeder modules). GPS Adapter module, including a 2m NPU to GPS Adapter cable and four screws. 2.4.1.2 Additional Installation Requirements A grounding cable with appropriate terminations for connecting the unit's ground terminal to the rack or to a ground connection. For installation in a 21" ETSI rack: two 21" ETSI rack adapters Other installation tools and materials 66 Installation Installing the GPS Adapter 2.4.2 The GPS Adapter The GPS Adapter connects the different GPS units to the NPU, adapting the different interfaces. Future versions may include an internal GPS module that will allow an all-in-one low-cost solution. A future optional addition of OCXO in the GPS Adapter box may provide an improved hold over solution when the GPS is not synchronized. The GPS Adapter is powered by 12 VDC supplied by the NPU. The GPS Adapter is installed in a 1U high panel (the same panel that is used for the ODU Power Feeders). Figure 2-14: GPS Adapter Front Panel Figure 2-15: GPS Adapter Rear Panel Table 2-15: GPS Adapter Connectors Name Connector Functionality BASE STATION INTERFACE 15 pin D-Type jack 1PPS and 16MHz synchronization signals (LVDS interface) to the NPU Power (12 VDC) from the NPU Serial control signals (RS-442 interface) from the NPU CMD 9 pin D-Type jack Serial control signals (RS-232 interface) to the Indoor GPS Receiver. 1PPS IN BNC jack 1PPS signal (TTL levels) from Indoor GPS Receiver BreezeMAX Modular Base Station System Manual 67 Chapter 2 - Installation Guidelines Table 2-15: GPS Adapter Connectors Name Connector Functionality ODU GPS RJ-45 jack 1PPS (RS-442 interface) from Outdoor GPS Receiver Serial control signals (RS-422 interface) to Outdoor GPS Receiver Power (12 VDC) to Outdoor GPS Receiver (GND) Grounding Screw Connection to ground (earth) Table 2-16: GPS Adapter LEDs Name Description Functionality PWR Input power indication Off - Power input failure Green - 12 VDC power supply from NPU is OK 1PPS 1PPS signal indication Blinking Green - 1PPS signal from GPS Receiver is detected Red - 1PPS signal is not detected Active GPS - ODU ODU GPS selection indication Green - indicates that the selected GPS Receiver: is ODU (Outdoor) Off - ODU GPS Receiver is not selected Active GPS - IDU IDU GPS selection indication Green - indicates that the selected GPS Receiver: is IDU (Indoor) Off - IDU GPS Receiver is not selected Active GPS - INT INT GPS selection indication Green - indicates that the selected GPS Receiver: is INT (Internal). Internal is not supported in current release. Off - INT GPS Receiver is not selected INT CLOCK Internal clock source indication Green - Internal 16MHz clock is ok (not supported in current release) Red - Internal clock is not available or clock failure 2.4.3 Installing the GPS Adapter To install the GPS Adapter: The GPS Adapter is installed on the 1U high panel that can be used also for installation of ODU Power Feeder modules. The panel is supplied with blank 68 Installation Installing the GPS Adapter covers. Release the nuts on the rear side of the panel to remove the blank cover you want to replace with the GPS Adapter. Attach the GPS Adapter module to the panel using the four screws supplied with it. Place the panel with the GPS Adapter (and optionally ODU Power Feeders) on a shelf/desk or install it in a 19" cabinet, next to the Base Station equipment. The distance from the Base Station equipment should allow connection of the 2 meters NPU to GPS Adapter cable. For installation in a 21" cabinet, attach suitable ETSI rack adapters to the panel. Connect one end of a grounding cable to the grounding screw located on the rear panel of the GPS Adapter and firmly tighten the grounding screw. Connect the opposite end of the grounding cable to a ground (earth) connection or to the cabinet, if applicable. Connect the NPU-to-GPS Adapter cable to the BASE STATION INTERFACE connector on the front panel of the GPS Adapter. Connect the other end of the cable to the GPS/SYNC IN connector of the NPU. Select the GPS Receiver to be used using the GPS SELECT miniature DIP switches: To use Outdoor GPS Receiver, move the ODU (left-most) switch to the ON (up) position. Make sure that the two other switches are in the OFF (down) position. To use Indoor GPS Receiver, move the IDU (middle) switch to the ON (up) position. Make sure that the two other switches are in the OFF (down) position. The INT (Internal) GPS Receiver option is not available in current release. Connect the applicable cable(s) to the selected GPS Receiver. NOTE Refer to the documentation supplied with the GPS Receiver for instructions on how to install and connect it. BreezeMAX Modular Base Station System Manual 69 Chapter 2 - Installation Guidelines 2.4.4 NPU to GPS Adapter Cable Table 2-17: NPU to GPS Adapter Cable Pin Out DB 15-pin Male (GPS Adapter) Micro 15-pin Female (NPU) Name Description IN_SENSE GPs Adapter Presence Indication EXT_16M_IN- 10 10 EXT_16M_IN+ External 16MHz clock from GPS Adapter, LVDS twisted pair (Not Used) NC Not Used 1PPS_IN+ 11 11 1PPS_IN- 1PPS signal from GPS Adapter, LVDS twisted pair, GPS_TX- 13 13 GPS_TX+ GPS_RX- 14 14 GPS_RX+ NC Not Used GND Ground GND Ground 12 12 NC Not Used 15 15 +12V 12 VDC to GPS Shell Shell Shield 70 Transmit communication channel from GPS, RS422 twisted pair Receive communication channel to GPS, RS422 twisted pair Installation Installing the GPS Adapter 2.4.5 GPS Adapter to Outdoor GPS Receiver Cable Table 2-18: GPS Adapter to Outdoor GPS Receiver Cable Pin Out 12-pin Bayonet (GPS Receiver) RJ 45 (GPS Adapter) Name Wire Color Description Power (12 VDC) Orange Twisted pair Ground Orange/White Receive- Blue Receive+ Blue/White Transmit- Brown Transmit+ Brown/White 11 1PPS+ Green/White 12 1PPS- Green NC Case BreezeMAX Modular Base Station System Manual RS422 twisted pair RS422 twisted pair RS422 twisted pair Shield 71 Chapter 2 - Installation Guidelines 72 Installation 3 Chapter 3 - Commissioning In This Chapter: “Configuring Basic Parameters of Base Station” on page 74 “Operation Verification” on page 80 Chapter 3 - Commissioning 3.1 Configuring Basic Parameters of Base Station 3.1.1 NPU Parameters Required for Management After completing the installation process, as described in the preceding chapter, some basic NPU parameters must be configured using the Monitor application via the MON port of the NPU. These parameters are necessary to enable remote management using SNMP or Telnet. If the NPU is in the default factory configuration, or if the IP parameters of either the Data or Management port are known, you may configure the parameters using Telnet. You may also use AlvariCRAFT, provided you know the IP parameters of one port and the Authorized Managers list in the NPU is either empty (default) or includes the IP address of the AlvariCRAFT station. Refer to Chapter 4 for information on how to access the Monitor application either via the MON port or via Telnet and how to use it. NOTE The default Installer password is "installer". Refer to the AlvariCRAFT User Manual for information on how to use it. The basic parameters are listed in Table 3-1. Refer to Chapter 4 for detailed information on the applicable parameters. Table 3-1: Basic NPU Parameters Management Option Parameters MGMT port Management Port IP address Management Port Subnet Mask Management Port Gateway Management Port Destination Subnet Management Port Destination Subnet Mask Management Port Management Traffic Enable/Disable 74 Commissioning Configuring Basic Parameters of Base Station Table 3-1: Basic NPU Parameters Management Option Parameters DATA port Data Port IP address Data Port Subnet Mask Data Port Gateway Data Port Management VLAN ID Data Port Management Traffic Enable/Disable Data Port Speed Authorized Managers (per manager) IP Address Send Traps Read Community Write Community The following are the guidelines for configuring the basic NPU parameters: All parameters of both ports should be configured. Otherwise, default values shall be used. If OOB management via a router connected to the Management port is used, the parameters should be configured to ensure different subnets for the Data port, the Management port (local OOB management) and the Management Port Destination. The Management Port Destination Subnet is the subnet behind a router connected to the Management port. NOTE It is highly recommended to use the Management port for local management only. Typically the port should be down (disconnected). CAUTION Do not configure the IP Address of the Management port to 0.0.0.0, as this will cause loss of management connectivity via the Data port. Authorized Manager(s) must be configured properly to enable remote management using AlvariSTAR (or another SNMP based application). BreezeMAX Modular Base Station System Manual 75 Chapter 3 - Commissioning NOTE If no Authorized Manager is defined in the device, it can be managed using SNMP by any station. If at least one Authorized Manager is defined, the device can be managed only by a station whose parameters match a defined Authorized Manager. After the basic NPU parameters have been configured, the Base Station can be managed remotely using either Telnet or SNMP-based management. To enable proper operation of the Base Station and all its components, the following parameters must also be configured: NOTE The following list includes only parameters that are mandatory for proper operation of the Base Station. Configuration of other parameters may be done either at the same time or later. 3.1.2 Base Station Configuration Parameters Switching Mode Operator ID Cell ID Duplex Mode (must be TDD) DL-UL Ratio External 1PPS Clock (must be enabled to support 1PPS from GPS) External 16MHz Clock (in this release must be disabled) Chain Number GPS Protocol Time Zone Offset From UTC 3.1.3 RADIUS Parameters 3.1.3.1 RADIUS General Parameters Shared Secret 76 Commissioning Configuring Basic Parameters of Base Station 3.1.3.2 RADIUS Authentication At least one Authentication server must be defined to enable RADIUS-based provisioning of services (in IP CS Switching Mode only one server can be defined). IP Address UDP Port Server Status (not applicable for units operating IP CS Switching Mode) 3.1.3.3 RADIUS Accounting At least one Accounting server must be defined to enable RADIUS-based accounting (in IP CS Switching Mode only one server can be defined). IP Address UDP Port Server Status (not applicable for units operating IP CS Switching Mode) 3.1.4 Radio Cluster Radio Cluster ID: Verify that all required Radio Cluster IDs are defined 3.1.5 ODU Define the necessary ODUs. For each ODU, configure the following: ODU ID Associated Radio Cluster Configured ODU Frequency Band Configured Tx Power Admin Status: Enable when completing the configuration process BreezeMAX Modular Base Station System Manual 77 Chapter 3 - Commissioning 3.1.6 AU 3.1.6.1 SW Files in NPU - Default SW File (Advanced Si) Name Action The following must be configured for each AU: 3.1.6.2 Unit Control - SW Versions Control 3.1.6.2.1 SW File Name Action 3.1.6.2.2 SU SW File Name Action 3.1.6.3 MAC Parameters Sector ID Maximum Cell Radius (km) 3.1.6.4 Phy Parameters Bandwidth 3.1.6.5 Multi Channel Parameters Diversity Mode The following parameters must be configured for each channel used if Diversity Mode is No Diversity. Otherwise, only Channel 1 needs to be configured: Associated ODU 78 Commissioning Configuring Basic Parameters of Base Station Downlink (Tx) Frequency (MHz) Admin Status: Enable when completing the configuration process 3.1.6.6 Multirate Parameters Uplink Basic Rate Minimum Number of Sub-Channels Downlink Basic Rate 3.1.6.7 Voice Parameters Maximum Number of Voice Calls (not applicable for IP CS Switching Mode) AU Minimum allocation 3.1.7 SU 3.1.7.1 SW Files in NPU - Default SW File (Advanced Si) Name Action BreezeMAX Modular Base Station System Manual 79 Chapter 3 - Commissioning 3.2 Operation Verification The following sections describe how to verify the correct functioning of the Outdoor Units, Indoor Units, Ethernet connection and data connectivity. 3.2.1 AU-ODU LEDs To verify the correct operation of the AU-ODU, examine the LED indicators located on the bottom panel of the outdoor unit. The following tables list the provided LEDs and their associated indications. NOTE Verifying the correct operation of the Outdoor Unit using the LEDs, as described below, is only possible after the configuration of basic parameters has been completed. Table 3-2: AU-ODU-LEDs Name Description Functionality PWR Power indication Off - Power failure Green - Power to ODU is OK, internal 3.3 VDC power supply is OK. ALARM IDU-ODU communication and synthesizer status indication Off - IDU-ODU communication is OK, synthesizer is locked. Red - IDU-ODU communication failure or synthesizer is not locked ETH Not Used 3.2.2 Base Station LEDs To verify the correct operation of the Base Station equipment, examine the LED indicators located on the front panels of the modules. The following tables list the LEDs of the Base Station modules and their associated indications. 80 Commissioning Operation Verification Table 3-3: AU-IDU LEDs Name Description Functionality PWR Power indication Off - AU-IDU is not powered Red - AU-IDU power supply failed (low power) Green - AU-IDU power is OK ALARM Alarm indication Off - AU-IDU is OK Red - AU-IDU failure WLINK Wireless link status indication Off - No SU is associated Green - At least one SU is associated WACT IDU transmission indication Off - No IDU transmission Green - IDU transmission OK SP Spare Not Used IP IP activity indication Off - No downlink (AU to SU) IP activity Green (blinking) - Downlink (AU to SU) IP activity ODU1 - ODU4 PWR IDU to ODU Power Indication Off - No IDU to ODU power output Red - IDU to ODU power output failed Green - IDU to ODU power output OK ODU1 - ODU4 ALRM IDU-ODU communication status Off - IDU-ODU communication OK Red - IDU-ODU communication failure HOT SWAP IDU readiness for hot swap removal Off: Power to the module is not disconnected, the AU-IDU is not ready for removal Blue: Power to the module can be disconnected and the AU-IDU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. BreezeMAX Modular Base Station System Manual 81 Chapter 3 - Commissioning Table 3-4: NPU LEDs Name Description Functionality PWR Power indication Off - NPU is not powered Red - NPU power failure Green - NPU power is ok ALRM NPU Alarm indication Off - NPU is OK Red - NPU failure BST ALRM Base Station chassis alarm indication Off - All Base Station modules are OK Red - Failure in one (or more) Base Station modules EXT ALRM External alarm indication Off - No alarm received via the AL IN connector Red - Alarm received via the AL IN connector MASTER GPS/SYNC Master/Slave (primary/secondary) operation indication Off - Secondary NPU (backup) GPS/IF clock synchronization functionality indication Off - GPS/IF clock synchronization is disabled Green - Primary NPU Green - GPS/IF clock synchronization is enabled HOT SWAP NPU readiness for hot-swap removal Off: Power to the module is not disconnected, the NPU is not ready for removal Blue: Power to the module can be disconnected and the NPU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. 82 Commissioning Operation Verification Table 3-5: PIU LEDs LED Status Description PWR MASTER Off Off Chassis is not connected to power Red Off Power is not connected or power input is out of range or PIU card is damaged. Chassis is powered by the redundant PIU Red Green Power input is out of range or PIU card damaged. Chassis is powered by the PIU Green Off Power to PIU is OK. PIU is in redundant mode and the chassis is powered from the other PIU Green Green Power to PIU is OK. The chassis is powered from the PIU HOT SWAP Off: Power from the module to the chassis is not disconnected, the PIU is not ready for removal Blue: Power from the module to the chassis can be disconnected and the PIU can be safely removed For instructions on using the HOT SWAP handles refer to Section 2.2.9. Table 3-6: PSU LEDs LED Status Description PWR ALRM Off Off No power or fatal damage Off Red Power input is out of range or PSU is damaged or PSU is inhibited by NPU Green Off Power is OK and PSU operates properly. Table 3-7: AVU LEDs LED Status Description PWR ALRM Off Off No 5V power input Red Red 12V power failed Green Red One or more fans have failed Green Off AVU operates properly BreezeMAX Modular Base Station System Manual 83 Chapter 3 - Commissioning 3.2.3 ODU Power Feeder LEDs To verify the correct operation of the ODU Power Feeder, examine the LED indicators located on the front panel of the unit. The following table lists the LEDs of the ODU Power Feeder and their associated indications. Table 3-8: ODU Power Feeder LEDs Name Description Functionality PWR Input power indication Off - ODU Power Feeder is not powered Green - ODU Power Feeder power is OK ODU PWR 1 - 4 Output power indications Off - AU-ODU-HP is not connected Red - Power output problem (short or overload) Green - AU-ODU-HP is connected and powered 3.2.4 GPS Adapter LEDs To verify the correct operation of the GPS Adapter, examine the LED indicators located on the front panel of the unit. The following table lists the LEDs of the GPS Adapter and their associated indications. Table 3-9: GPS Adapter LEDs Name Description Functionality PWR Input power indication Off - Power input failure Green - 12 VDC power supply from NPU is OK 1PPS 1PPS signal indication Blinking Green - 1PPS signal from GPS Receiver is detected Red - 11PPS signal is not detected Active GPS - ODU ODU GPS selection indication Green - indicates that the selected GPS Receiver: is ODU (Outdoor) Off - ODU GPS Receiver is not selected Active GPS - IDU IDU GPS selection indication Green - indicates that the selected GPS Receiver: is IDU (Indoor) Off - IDU GPS Receiver is not selected 84 Commissioning Operation Verification Table 3-9: GPS Adapter LEDs Name Description Functionality Active GPS - INT INT GPS selection indication Green - indicates that the selected GPS Receiver: is INT (Internal). Internal is not supported in current release. Off - INT GPS Receiver is not selected INT CLOCK Internal clock source indication Green - Internal 16MHz clock is ok (not supported in current release) Red - Internal clock is not available or clock failure 3.2.5 Verifying the Ethernet Connection After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity Indicator, which is the yellow LED embedded in the DATA port connector, is on. This indicates that the unit is connected to an Ethernet segment. The Ethernet Activity Indicator, which is the green embedded LED, should blink whenever the unit receives or transmits traffic on the DATA port. BreezeMAX Modular Base Station System Manual 85 4 Chapter 4 - Operation and Administration In This Chapter: “BreezeMAX System Management” on page 88 “The Monitor Program” on page 90 “The NPU's Main Menu” on page 95 “Base Station Menu” on page 97 “NPU Menu” on page 125 “Radio Cluster Menu” on page 143 “ODU Menu” on page 146 “AU Menu” on page 152 “SU Menu” on page 172 “Services Menu” on page 199 “NPU Parameters Summary” on page 243 Chapter 4 - Operation and Administration 4.1 BreezeMAX System Management All BreezeMAX system components associated with a Base Station are managed via the Base Station's NPU module. The other system components (AUs and SUs) are not accessed directly: each configuration change or status enquiry is sent to the NPU that communicates with other system components. NOTE The SU can also be managed directly from its Ethernet port using the Installer Monitor program or the built-in Web Server. These options are available to support the installation process and enable special tests and performance monitoring at the SU's site. The following management options are available: SNMP based management using AlvariSTAR (or another network management system customized to support management of BreezeMAX). Using Telnet to access the embedded Monitor application. Accessing the embedded Monitor application locally via the MON port. NOTE It is not possible to manage the Base Station via the wireless link (from the SU’s side). Two management access methods are available to support management using SNMP and/or Telnet: Out-Of-Band (OOB) management via the dedicated MGMT port. In-Band (IB) management via the DATA port. NOTE To enable remote management of devices behind the SU, including Voice and Networking Gateways, IP connecctivity with the managed device is needed. This is possible only via the Data port. Typically, BreezeMAX systems will be managed using AlvariSTAR or another SNMP based network management system. 88 Operation BreezeMAX System Management This chapter describes how to manage the system using the Monitor application. For information on managing the system using AlvariSTAR refer to the Applicable AlvariSTAR documentation. NOTE To enable remote management (using SNMP and/or Telnet), the parameters of the applicable port (MGMT and/or DATA) must first be configured via the MON port. For details on the applicable parameters refer to Section 4.5.3.1 (Management Port) and Section 4.5.3.2 (Data Port). BreezeMAX Modular Base Station System Manual 89 Chapter 4 - Operation and Administration 4.2 The Monitor Program 4.2.1 Accessing the Monitor Program To access the Monitor program via the MON connector: Use the Monitor cable to connect the MON connector of the NPU to the COM port of your ASCII ANSI terminal or PC. The COM port connector on the Monitor cable is a 9 pin D type plug. Run a terminal emulation program, such as HyperTerminal™. Set the communication parameters as shown in the following table: Table 4-1: COM Port Configuration Parameter Value Baud Rate 9600 Data Bits Stop Bits Parity None Flow Control Xon/Xoff Port Connected COM port The password prompt is displayed. Enter the password and press the Enter key to get to the Main menu. NOTE There are 3 access levels, as described in Section 4.2.2. The default password for each of the access levels is: 90 Access Level Default Password Administrator admin Installer installer Monitor monitor Operation The Monitor Program To access the Monitor program using Telnet: The PC used for accessing the Monitor program should be configured according to the parameters configured for the applicable port (MGMT or DATA port). If you connect directly to the MGMT or DATA port, use a crossed Ethernet cable. Run the Telnet program connecting to the IP address of the connected port. The Enter the password message is displayed. Enter the password and press the Enter key to get to the Main menu. NOTE Following three unsuccessful login attempts (using incorrect passwords), the monitor program is blocked for 10 minutes. If you forgot the Installer or Monitor password, the Administrator can login (with the Administrator password) and define a new password for Installer and/or Monitor access level. If you forgot the Administrator password, type "help" to receive a challenge string consisting of 24 characters. Contact Alvarion's Customer Service and provide the challenge string (after user identification) to receive a temporary password. You can use this password only once to enter the program. The password must be changed during the session to a different "permanent" password. The administrator should be notified of this new password. Five consecutive errors in entering the temporary password will invalidate it. In this case, repeat this procedure to receive a new challenge string for a new temporary password. 4.2.2 Using the Monitor Program This section describes the Monitor program structure and navigation rules. There are three access levels to the Monitor program. The available actions depend on the access level (password) used for accessing the program: Administrator: Read/Write permissions for all parameters. The default password is admin. Installer: Read-only permission for the Services menu, Read/Write permissions for all other options excluding the Change Password option. The default password is installer. Monitor: Read-only permissions for all parameters. The default password is monitor. BreezeMAX Modular Base Station System Manual 91 Chapter 4 - Operation and Administration Each menu or submenu specifies the unit type (BreezeMAX/NPU), the IP address of the port used for accessing the Monitor program (when using the MON port, there is no IP address), the running SW version and a description of the menu. Each menu or submenu displays a list of numbered options. To access an option, enter the number of the required option at the > prompt and press the Enter key. At any point in the program, you can use the Esc key to return to the previous menu (one level up) without applying any change. The first selectable item in most menus is the Show option, enabling to view the current configuration of the applicable parameters. For some menus some additional status information is displayed. For certain parameters, an updated value is applied only after reset or after entering a specific command. In these parameters, the configured value may differ from the actual value. If the configured value differs from the actual value both values will be displayed, where the first one is the configured value and the second is the actual value. For example: "Bandwidth (MHz): 5, 3.5" means that the configured bandwidth, to be applied after the next reset, is 5 MHz, and the current actual bandwidth is 3.5 MHz. For certain parameters the actual values may not be available (such as when pre-configuring an AU that is not yet installed). For these parameters a value of NA (Not Available) will be displayed. The Update/Add options will display all applicable parameters line by line, allowing to conveniently edit all of them. The current value is displayed for each parameter. To keep the current value - press Enter. To change it - enter a new value and press Enter. Press the Tab key for context sensitive help text (where applicable). If an erroneous value was entered - the reason of the error or help text will be displayed, and the parameter entry text will be displayed again. Many menus include a Select By option, enabling to get a sub-menu for a selected entity according to the selection criteria. If the Monitor program is not used for 10 minutes, the session will be automatically terminated. 92 Operation The Monitor Program Select the Exit option in the Main menu to exit the program and terminate the session. BreezeMAX Modular Base Station System Manual 93 Chapter 4 - Operation and Administration 4.3 IP Addresses Configuration The following IP addresses should not be used and will be rejected: 0.0.0.0 - 0.255.255.255 255.255.255.255 (Broadcast) 224.0.0.0 - 239.255.255.255 (Multicasts, RFC 3171 D) Note that the following IP addresses are reserved for specific applications: 10.0.0.0 - 10.255.255.255 (Private IP addresses, RFC 1918 A) 127.0.0.0 - 127.255.255.255 (Localhost Loopback Address, RFC 1700 A) 169.254.0.0 - 169.254.255.255 (Zeroconf / APIPA, RFC 3330 B) 172.16.0.0 - 172.31.255.255 (Private IP addresses, RFC 1918 B) 192.0.2.0 - 192.0.2.255 (Documentation and Examples, RFC 3330 C) 192.88.99.0 - 192.88.99.255 (IPv6 to IPv4 relay Anycast, RFC 3068 C) 192.168.0.0 - 192.168.255.255 (Private IP addresses, RFC 1918 C) 198.18.0.0 - 198.19.255.255 (Network Device Benchmark, RFC 2544 C) 240.0.0.0 - 255.255.255.255 (Reserved, RFC 1700 E) 94 Operation The NPU's Main Menu 4.4 The NPU's Main Menu The Main menu of the NPU Monitor program includes the following options: 1 - Base Station 2 - NPU 3 - Radio Cluster 4 - ODU 5 - AU 6 - SU 7 - Services X - Exit 4.4.1 Base Station Menu The Base Station menu enables to view general base station status information, to configure general base station parameters, and to view active alarms or traps log. For details refer to Section 4.5. 4.4.2 NPU Menu The NPU menu enables configuring the NPU's DATA and MGMT ports, defining authorized managers, managing the NPU's SW versions and viewing current status and configurations. For details refer to Section 4.6. 4.4.3 Radio Cluster Menu The Radio Cluster menu enables viewing the details of existing Radio Clusters, defining new Radio Clusters, updating the parameters of an existing Radio Cluster and deleting a Radio Cluster from the database. For details refer to Section 4.7. 4.4.4 ODU Menu The ODU menu enables viewing the status and configuration details of existing ODUs, configuring the parameters of new ODUs including pre-configuration of ODUs that are not yet installed, updating the parameters of existing ODUs and deleting ODUs from the database. For details refer to Section 4.8. BreezeMAX Modular Base Station System Manual 95 Chapter 4 - Operation and Administration 4.4.5 AU Menu The AU menu enables configuring the parameters of selected AUs, including pre-configuration of AUs that are not yet installed. It also enables managing AUs SW versions and viewing current status, configurations and performance information. For details refer to Section 4.9. 4.4.6 SU Menu The SU menu enables viewing summary information of all relevant SUs, configuring the parameters of a selected SU and defining new SUs. It also enables managing a selected SU's SW versions and viewing its current status, configuration and performance information. For details refer to Section 4.10. 4.4.7 Services Menu The Service menu enables viewing, updating and adding service profiles and subscribers, and allocating services to subscribers. It also enables viewing and updating filtering rules and the MAC Address Deny List. For details refer to Section 4.11. 4.4.8 Exit Select the Exit option (X) to exit the Monitor program and terminate the Telnet session. 96 Operation Base Station Menu 4.5 Base Station Menu The Base Station menu includes the following options: Show Configuration Alarms and Traps RADIUS Licenses 4.5.1 Show Select this option to view the current value/selected option of configurable parameters. Refer to Section 4.5.2 for more details on these parameters. In addition, some general status information is displayed, as follows: Configurable Parameters: Device Name Device Location ATPC Status Optimal Uplink RSSI (dBm) Operator ID Cell ID Duplex Mode DL-UL Ratio External 1 PPS Clock External 16 MHz Clock Status Information: Slots status, displaying for each slot (1-9) the following: BreezeMAX Modular Base Station System Manual 97 Chapter 4 - Operation and Administration ¾ Installed module type (or "Not Installed" for an empty slot) ¾ Operational status (OK/Fault) of an installed module Operational status (OK/Fault) of the AVU module PIU slots status, displaying for each PIU slot: ¾ Mode: Master, Redundant or Not Installed ¾ Status (OK/Fault) of an installed module ¾ Version (Normal/High Power) of an installed module PSU slots table, displaying the status of each slot: Not installed, OK or Fault. Licenses Status CPEs License Bank status Base Station License Status For details refer to Section 4.5.5. Figure 4-1: Base Station Chassis Slot Assignment 4.5.2 Configuration Select this option to view or configure the general Base Station parameters: “Device Name “Device Location 98 Operation Base Station Menu “Switching Mode “ATPC “Cell “Duplex “Synchronization 4.5.2.1 Device Name The Device Name parameter provides identification information for the Base Station equipment. The device name consists of up to 255 printable characters. The default Device Name is a null string (empty). 4.5.2.2 Device Location The Device Location parameter provides location information for the Base Station equipment. The location name consists of up to 255 printable characters. The default Device Location is a null string (empty). 4.5.2.3 Switching Mode The Switching Mode parameter defines the convergence sublayer (CS) used in the network infrastructure. Ethernet CS is applicable to the current generation of layer 2 based services. IP CS Switching Mode is compatible with the infrastructure of next generation WiMAX systems, providing VPN/L2TP support using a DHCP proxy in the NPU. IP CS Switching Mode provides smooth upgrade to systems that fully support the IEEE 802.16e standard, with the same “Look and Feel” of service provisioning. The operator will only have to replace his access equipment while keeping most of his network equipment unchanged. The default Switching Mode is Ethernet CS. A change in the Switching Mode is applied after resetting the NPU. BreezeMAX Modular Base Station System Manual 99 Chapter 4 - Operation and Administration The following table lists the functional changes that are applied after switching to IP CS Switching Mode. For more details on using the IP CS Switching Mode refer to the IP CS Implementation document. Table 4-2: IP CS Switching Mode Functional Changes Parameter Change Description ServicesGeneral The General Service parameters are not applicable for IP CS Switching Mode. The Working Mode is always Advanced Mode. ServicesSubscribers The Subscribers parameters are not applicable for IP CS Switching Mode. ServicesServices All previous Ethernet CS Switching Mode Services are deleted from the database. Services can only be accepted from AAA server, and are read-only. A Service includes the following configurable parameters: Service Name, Service Type, Service Profile Name, SU MAC Address, Service VPL ID (new parameter that defines the VLAN ID to be used in the network side of the NPU) and Admin Status. The following parameters, used in Ethernet Switching Mode Services, are not applicable for IP Switching Mode Services: Subscriber Name, VLAN List, Hybrid VLAN Mode, VLAN Classification Mode, Access VLAN. ServicesService Profiles All previous Ethernet CS Switching Mode Service Profiles are deleted from the database. There are two new Service Types in IP CS Switching Mode: IP CS Data and IP CS VoIP (the previous L2, PPPoE and VoIP Service Types used in Ethernet CS Switching Mode are not applicable for IP CS Switching Mode. Each Service Profile includes the following configurable parameters: Service Type (IP CS Data or IP CS VoIP), Service Profile Name, Priority Classifier. IP CS VoIP Service Profiles use the @@IP Mode VoIP@@ Forwarding Rule. The following configurable parameters, used in Ethernet Switching Mode Service Profiles, are not applicable for IP Switching Mode Service Profiles: VLAN Transparency Mode, VPL ID, Priority Marking Mode, Priority Marking Value, Forwarding Rule, Maximum Number of Voice Calls. 100 Operation Base Station Menu Table 4-2: IP CS Switching Mode Functional Changes Parameter Change Description ServicesForwarding Rules All previous Ethernet CS Switching Mode Forwarding Rules are deleted from the database. A single Forwarding Rule named @@IP Mode VoIP@@ is provided for IP CS VoIP Service Type. Certain parameters of this Forwarding Rule (except the Name and Service Type) can be updated. This Forwarding Rule cannot be deleted. It is not possible to define additional Forwarding Rules. The default values of the @@IP Mode VoIP@@ Forwarding Rule configurable parameters are: Unicast Relaying: Enabled Broadcast Relaying: Enabled Unknown forwarding Policy: Forward Multicast QoS Profile Name: @@IP Mode VoIP@@ ServicesPriority Classifiers All previous Ethernet CS Switching Mode Priority Classifiers are deleted from the database. The Priority type is not configurable, and it is always DSCP (802.1p prioritization is not available in IP CS Switching Mode). ServicesQoS Profiles All previous Ethernet CS Switching Mode QoS Profiles are deleted from the database. A single QoS Profile named @@IP Mode VoIP@@ is provided for IP CS VoIP Service Type. All parameters of this QoS Profile can be updated, and it can also be deleted from the database. Additional QoS Profiles can be defined. The default values of the @@IP Mode VoIP@@ QoS Profile configurable parameters are: Name: @@IP Mode VoIP@@ QoS Type: BE CT: Short (non-configurable) MIR (Kbps): 128 Pre-configured Profiles The pre-configured profiles are not available in IP CS Switching Mode. BreezeMAX Modular Base Station System Manual 101 Chapter 4 - Operation and Administration Table 4-2: IP CS Switching Mode Functional Changes Parameter Change Description Services-Filtering Rules, Interface Filtering and MAC Addresses Deny List All filtering related parameters are not applicable for IP CS Switching Mode. RADIUS All previous Ethernet CS Switching Mode Authentication and Accounting parameters are deleted from the database. In IP CS Switching Mode,only one Authentication Server and one Accounting Server can be defined. The configurable Server Status and read-only Activity Status parameters are not applicable. Typically, the IP Addresses of the Authentication/Accounting Server(s) should be set to the IP address of the Data Port Default Gateway that serves as a proxy for the AAA server(s). DRAP related parameters DRAP is not used in IP CS Switching Mode. Hence, the following configurable and read-only parameters/options are not applicable: In NPU menu: Voice (DRAP TTL Retries) In AU menu: Maximum Number of Voice Calls, Active Voice Calls In SU menu: Number of Gateways, Voice/Networking Gateways, SU IDU Type 4.5.2.4 Operation Mode (AU and SU) Not applicable for IP CS Switching Mode (Operation Mode is always Advanced Si) SU Status Not applicable for IP CS Switching Mode (SU Status is always Temporary). Add SU, Delete SU Not applicable for IP CS Switching Mode. Create Backup The Profiles and Services option and the Filtering option are not applicable for IP CS Switching Mode. SW Files in NPU (AU, SU) Default SW File (Standard) is not applicable for IP CS Switching Mode (for both AU and SU). SU MAC (Standard FDD) and Phy (Standard FDD) Parameters Not applicable for IP CS Switching Mode (Operation Mode is always Advanced Si). ATPC BreezeMAX employs an Automatic Transmit Power Control (ATPC) algorithm to dynamically adapt the transmit power of each SU so that it is received by the 102 Operation Base Station Menu AU-ODU at an optimal level. ATPC is required to minimize the interference caused by a strong signal of an SU from one sector to other SU units in another sector. The ATPC algorithm will cause the SU to transmit a power level that minimizes the interference to other SU units, while maintaining a sufficient receiving power level. The algorithm is managed by the AU and optimal values are calculated separately for each SU based on the actual level at which it is received by the AU-ODU. MAP messages transmitted to the SUs include information on the estimated power level change required to achieve optimal transmit power level. When several SUs transmit simultaneously each one increases the total level of noise. If a “strong” SU transmits simultaneously with a very “weak” SU, the noise induced by the “strong” one may cause the SNR of the “weak” SU to be too low. In order to avoid this, all SUs should not be too “strong” – their RSSI at the AU-ODU should be not be higher than a nominal RSSI (typically -74 dBm), defined by the Optimal Rx RSSI parameter. Changing the amount of subchannels may cause change in RSSI. In order to avoid this, reduction in amount of subchannels from 16 (full bandwidth) to 8, 4, 2 or 1, will be accompanied with a reduction of 3, 6, 9 or 12 dBm, respectively, in the SU’s Tx power (unless the RSSI of the SU is below the nominal RSSI level). The ATPC menu enables viewing/updating the following parameters for all AUs: 4.5.2.4.1 ATPC Enable/Disable The ATPC Enable/Disable parameter controls whether the ATPC algorithm will be used to determine current optimal transmit level for each SU served by the Base Station. The default is Enable. NOTE The ATPC algorithm should always be enabled. The option to disable it is available to support certain tests. After each reset, the Base Station boots with the ATPC enabled, disregarding its status before the device was reset. 4.5.2.4.2 Optimal Uplink RSSI The Optimal Uplink RSSI sets the target level at which all transmissions should be received by the AU-ODUs for optimal performance. The range is -90 to -60 (dBm). BreezeMAX Modular Base Station System Manual 103 Chapter 4 - Operation and Administration The default is -73 dBm. NOTE The actual range that can be accepted by AUs operating in TDD mode is -80 to -74 dBm. If a value higher than -74 dBm is configured at the Base Station level, the actual value in the AUs will be -74 dBm (hence the actual default at the AUs is -74 dBm). If a value lower than -80 dBm is configured at the Base Station level, the actual value in the AUs will be -80 dBm. You can see the actual value of the Optimal Uplink RSSI in the Show menu of each AU (if the configured value differs from the actual one, both will be shown, starting with the configured value). 4.5.2.5 Cell The Cell parameters provide a unique identifier for the Base Station, and they are common to all AUs in the Base Station. Updated Cell parameters are applied for each AU after resetting the AU (or after resetting the NPU, which causes reset of all AUs). The Cell menu enables viewing/updating the following parameters: 4.5.2.5.1 Operator ID A unique identifier of the network. The same Operator ID must be defined for all Base Stations in the network, and it should not be used by any Base Station belonging to another network in the same area. The Operator ID consists of 3 groups of up to three digits each, where the range for each group is 0 to 255. The default Operator ID is 186.190.0. Changes in the value configured for the Operator ID are applied only after reset. 4.5.2.5.2 Cell ID A unique identifier of Base Station. The same Cell ID should not be used by any other Base Station belonging to the network. The Cell ID consists of 2 groups of up to three digits each, where the range for each group is 0 to 255. The default Cell ID is 0.250. Changes in the value configured for the Cell ID are applied only after reset. 4.5.2.6 Duplex The Duplex parameters define the operation mode of the system. These parameters are applied after reset. The Duplex menu enables viewing/updating the following parameters: 4.5.2.6.1 Duplex Mode The operation mode of the system: TDD or FDD. 104 Operation Base Station Menu NOTE In systems that support only a single mode of operation, any attempt to change the Duplex Mode to a mode that is not supported will be rejected. If there is a mismatch between the configured value and the mode supported by the AUs, a suitable error message and trap will be sent and the system will not become operational until proper configuration is completed. The default is TDD. In the current release only TDD mode is supported, and the Duplex Mode should not be changed. A change in the configured Duplex Mode is applied only after reset. 4.5.2.6.2 DL-UL Ratio Applicable only when the Duplex Mode is set to TDD. Defines the ratio of transmit (Down Link) time to receive (Up Link) time, in percents. The available values are: 1: 65-35 2: 60-40 3: 55-45 4: 50-50 5: 45-55 6: 40-60 7: 35-65 When Sub-channelization is enabled (Minimum Number of Sub-Channels is other than 16), some DL-UL Ratios are not supported for certain combinations of Bandwidth, AU Minimum Allocation and Maximum Cell Radius: For 3.5 MHz bandwidth and AU Minimum Allocation of 5 Symbols, UL-DL Ratios of 65-35 and 60-40 are not supported, regardless of Maximum Cell Radius. UL-DL Ratio of 55-45 is not supported for Maximum Cell Radius of 30 km or higher. For 3.5 MHz bandwidth and VAU Minimum Allocation of 3 Symbols, UL-DL Ratio of 65-35 is not supported, regardless of Maximum Cell Radius. UL-DL Ratio of 60-40 is not supported for Maximum Cell Radius of 20 km or higher. UL-DL Ratio of 55-45 is not supported for Maximum Cell Radius of 50 km. BreezeMAX Modular Base Station System Manual 105 Chapter 4 - Operation and Administration For 5 MHz bandwidth and AU Minimum Allocation of 5 Symbols, UL-DL Ratio of 65-35 is not supported for Maximum Cell Radius of 40 KM or higher. These combination will be rejected by the device, and a suitable trap will be issued. For all other combinations of Bandwidth and AU Service Type, all DL-UL Ratios are supported for all values of Maximum Cell Radius. The default is 50-50 (%). A change in the configured DL-UL Ratio is applied only after reset. CAUTION The DL-UL Ratio of all Base Stations in the same coverage area (neighboring cells) must be set to the same value to ensure optimal performance and avoid uplink saturation. 4.5.2.7 Synchronization The Synchronization menu includes the following options: “Clock “Chain “GPS Info 4.5.2.7.1 Clock The Clock parameters define the source for the main clocks in the system. These parameters are applied after reset. The Clocks menu enables viewing/updating the following parameters: 4.5.2.7.1.1 External 1PPS Clock The 1PPS (Pulse Per Second) clock is used to determine the air-frame start time. Assuming that all systems use the same air-frame size and DL/UL Ratio, then, when the 1PPS clock is received from a GPS system, this mechanism ensures inter-site and intra-site synchronization among all sectors, preventing cross interference and saturation problems. When using the internal 1PPS clock (derived from the selected 16 MHz clock source), only intra-site synchronization among sectors can be achieved. The available options are Enable (use external 1PPS clock source) and Disable (use internal 1PPS clock source derived from the selected 16 MHz clock). The default is Enable. 106 Operation Base Station Menu 4.5.2.7.1.2 External 16 MHz Clock The 16 MHz clock source is used for generation of all main clocking signals in the system, including the internal 1PPS clock. Using an external, accurate 16 MHz clock source will enable better hold-over of the 1PPS clock upon temporary loss (or reduced reliability when receiving less than 4 satellites) of the external 1PPS clock. This will allow a longer time of continued operation before appearance of interferences due to clock drifts among Base Stations. The available options are Enable (use external 16 MHz clock source) and Disable (use internal 16 MHz clock source). The default is Disable In the current release, external 16 MHz clock from the GPS Adapter is not available. 4.5.2.7.2 Chain Future versions of BreezeMAX will enable chaining of co-located Base Stations to fully support intra-site synchronization. When two or more Base Stations are chained, all clocks and additional parameters required to ensure fully synchronized operation of all sectors are sent from the Master Base Station to other Base Stations. The Chain menu includes parameters that must be shared by all Base Stations belonging to the same chain, where most of them should be configured only in the Master Base Station (they will be read-only in other chained Base Stations). In the current release chaining is not supported yet and all Base Stations are configured as Master Base Stations. The Chain menu includes the following: 4.5.2.7.2.1 Chain Number In future releases, when chaining will be fully supported, the Chain Number will be used as a unique identifier of a chain. All Base Stations belonging to the same chain should be configured with the same Chain Number. The Chain Number can be used by a central management system to guarantee that certain limitations are met: in each chain, one, and only one Base Station should be defined as Master. Only one Base Station can be defined as Redundant (backup to the Master). The range is from 1 to 1500. The default is 0, indicating that a Chain Number is not configured yet. A valid Chain Number must be configured, and this number must be unique in the system to properly support future implementation of chaining. BreezeMAX Modular Base Station System Manual 107 Chapter 4 - Operation and Administration 4.5.2.7.2.2 GPS Supported This is a read-only parameter indicating whether the use of GPS is supported by the Base Station (through the Redundant CPLD in the NPU). The options are Supported or Not Supported. 4.5.2.7.2.3 GPS Protocol The GPS Protocol defines the communication protocol with the GPS receiver. The available options are None, Trimble (for Outdoor GPS Receiver) and Symmetricom (for Indoor GPS Receiver). The default is Trimble. 4.5.2.7.2.4 Time Zone Offset From UTC This is the offset of the local time from UTC (Coordinated Universal Time). The range is from -12:00 up to +13:00 in 30 minutes resolution. The format must be either -XX:YY or +XX:YY where YY is either 00 or 30. The default is +02:00. 4.5.2.7.2.5 Stop Tx After Hold Over Timeout For initial synchronization, a minimum of four satellites must be received properly (meeting certain criteria). Upon losing the 1PPS clock from the GPS, or if the received clock is not considered accurate enough because the number of received satellites dropped below the minimum (two satellites), the local 1PPS clock will be generated using the available 16 MHz clock. After a certain time (defined by the Hold Over Passed Timeout parameters described below), it is assumed that due to clock drifts there might be interferences among sectors belonging to the Base Station and sectors belonging to neighboring Base Stations). If the Stop Tx After Hold Over Timeout parameter is set to Enable, the Base Station will stop transmitting after this timeout (unless the number of properly received satellites has increased again to four or more), to prevent interferences to the sectors belonging to other Base Stations. If it is set to Disable, transmissions will continue indefinitely, at the expense of potential interferences to sectors belonging to other Base Stations. The default is Disable (Hold Over indefinitely). 4.5.2.7.2.6 Hold Over Passed Timeout (Min) This parameter defines the Hold Over timeout, after which there might be interferences to other sectors. When the Stop Tx After Hold Over Timeout is enabled, transmissions will stop after this timeout. When the Stop Tx After Hold Over Timeout is disabled, this timeout is used to generate a trap indicating that there might be interferences to neighboring sectors. 108 Operation Base Station Menu The range is from 0 to 2880 (minutes). The default is 30 (minutes). 4.5.2.7.3 GPS Info The GPS Info menu displays read-only information received from the GPS receiver (when available). Currently this information is available only from the Outdoor GPS Receiver. The displayed details include: Number Of Received Satellites: The number of satellites received by the GPS receiver. For proper operation at least four satellites should be received. Longitude: The longitude as calculated by the GPS receiver. The format is , where xx is the longitude in degrees, yy.yyy is in minutes (decimal format), and A is either N (North) or S (South). For example, 42 Deg 06.512 Min, N. Latitude: The latitude as calculated by the GPS receiver. The format is xx Deg yy.yyy Min, B, where xx is the latitude in degrees, yy.yyy is in minutes (decimal format), and B is either E (East) or W (West). For example, 024 Deg 25.290 Min, E. Altitude: The altitude in meters as calculated by the GPS receiver. For example: 00048,M Calculated Local Date and Time: The local date and time (using 24 hours clock) as calculated using the data received from the GPS receiver and taking into account the configured Time Zone Offset From UTC. The display format is: hh;mm;ss dd;mm;yyyy. For example: 13:04:23, 12/07/2006. Navigation Processor SW Version: The number and date of the Navigation Processor SW Version in the format 0xYY 0xZZ dd/mm/yyyy, where XX and YY are the Major and Minor SW Version Numbers in hexadecimal digits, respectively. For example: 0x1A 0x1F 11/3/2006 means that the Major SW Version Number is 1A (hex), the Minor SW Version Number is 1F (hex), and the SW Version release date is 11 March 2006. Signal Processor SW Version: The number and date of the Signal Processor SW Version in the format 0xYY 0xZZ dd/mm/yyyy, where XX and YY are the Major and Minor SW Version Numbers in hexadecimal digits, respectively. For example: 0x18 0x2B 11/3/2005 means that the Major SW Version Number is 18 (hex), the Minor SW Version Number is 2B (hex), and the SW Version release date is 11 March 2005. BreezeMAX Modular Base Station System Manual 109 Chapter 4 - Operation and Administration 4.5.3 Alarms and Traps The Alarms and Traps menu enables viewing the active alarms or the traps log, filtering the displayed traps and enabling/disabling traps. The available options are: Show Active Alarms Traps Display Filter Show Traps Log Trap Configuration 4.5.3.1 Show Active Alarms Select to view the currently active alarms. For more details on active alarms refer to the Traps and Alarms document. 4.5.3.2 Traps Display Filter Select to view/update the filtering criteria for the Traps Log display. The configurable filtering criteria are: 4.5.3.2.1 Minimum Severity The Minimum Severity parameter enables defining the minimum severity filter. Traps whose severity is below the defined severity will not be displayed. The options are Critical, Major, Minor, Warning and Info. The default is Info severity, which means that all the traps in the log will be displayed. 4.5.3.2.2 Days The Days parameter enables defining the period for which traps will be displayed. The available options are from 1 to 31 days. Only traps that occurred within the last N days, where N is the value selected for this parameter, will be displayed. The default is 31 days. 4.5.3.3 Show Traps Log Select to view the traps log. The traps will be displayed based on the filtering criteria defined by the Minimum Severity and Days parameters in the Traps 110 Operation Base Station Menu Display Filtering option, up to a maximum of the last 1000 traps. For more details refer to the Traps and Alarms document. 4.5.3.4 Trap Configuration The Trap Configuration menu enables viewing current parameters of all traps and updating the parameters of a selected trap. It also enables viewing traps with modified parameters (different from the default) and restoring the configuration of all modified traps to their default values. The available options are: Show Trap Status Admin Status Severity Suppression Interval 4.5.3.4.1 Show Traps Status Select this option to view a list of all traps and their parameters. For each trap, the following details are displayed: Trap ID Name Admin Status (the default Admin Status for all traps is Enabled) Default Severity Current Severity Suppression Interval (in seconds. The default Suppression Interval is 0, which means no suppression). 4.5.3.4.2 Admin Status The Admin Status menu enables viewing a list of all traps with Admin Status Disabled, updating the Admin Status of a selected trap and restoring the Admin Status of all traps to the default Enabled status. The Admin Status menu includes the following options: BreezeMAX Modular Base Station System Manual 111 Chapter 4 - Operation and Administration Show Disabled Traps List: Displays all traps with Admin Status Disabled (the default Admin Status for all traps is Enabled). Update: Enables modifying the Admin Status of a selected trap. Restore Defaults: Enables restoring the Admin Status of all traps to Enable. 4.5.3.4.3 Severity The Severity menu enables viewing a list of all traps with Severity that differs from the default severity, updating the Severity of a selected trap and restoring the Severities of all traps to the default severities. The Severity menu includes the following options: Show Traps with Modified Severity: Displays all traps with Severity that differs from the default severity. Update: Enables modifying the Severity of a selected trap. Restore Defaults: Enables restoring the Severities of all traps to the default severities. 4.5.3.4.4 Suppression Interval The Suppression Interval is the minimum time between consecutive transmissions of the same trap. This parameter can be used to prevent excessive retransmissions of the same trap. The Suppression Interval menu enables viewing a list of all traps with Suppression Interval that differs from the default suppression interval, updating the Suppression Interval of a selected trap and restoring the Suppression Intervals of all traps to the default value of 0 (no suppression). The Severity menu includes the following options: Show Traps with Modified Suppression Interval: Displays all traps with Suppression Interval that differs from the default suppression interval, which is 0 (no suppression). Update: Enables modifying the Suppression Interval of a selected trap. The available range is from 0 to 86,400 (seconds). 0 means no suppression. Restore Defaults: Enables restoring the Suppression Intervals of all traps to the default value (0). 112 Operation Base Station Menu 4.5.4 RADIUS Managing a large number of users creates the need for significant administrative support together with careful attention to security, authorization and accounting. The use of RADIUS (Remote Authentication Dial In User Service) enables operators to manage a single database of users, supporting authentication (verifying user name and password) as well as configuration information detailing the type of service to deliver to the user and the traffic that the user transmitted and received, for billing proposes. RADIUS is a protocol for carrying authentication, authorization, and configuration information between a Network Access Server (NAS), which desires to authenticate its links, and a shared Authentication server. A Network Access Server operates as a client of RADIUS. The client is responsible for passing user information to designated RADIUS server(s(, and then acting on the response. RADIUS servers are responsible for receiving user connection requests, authenticating the user, and then returning all configuration information necessary for the client to deliver service to the user. In BreezeMAX systems, a RADIUS NAS is implemented in each Base Station. Transactions between the client and RADIUS server are authenticated using Password Authentication Protocol (PAP) through encryption based on RSA Message Digest Algorithm MD5 and a Shared Secret, which is never sent over the network. The Access-Request is submitted to the RADIUS server via the network. If no response is returned within a length of time, the request is re-sent a number of times. Once the RADIUS server receives the request, it validates the sending client. A request from a client for which the RADIUS server does not have a shared secret must be silently discarded. If the client is valid, the RADIUS server consults a database of users to find the user whose User Name matches the request. The user entry in the database contains the User Password that must be verified. The SU authentication is a part of the network entry process: User Name and Password should be configured in the SU. All required Service Profiles and theitr components should be configured in the NPU (see “Defining Service Profiles” on page 235. The RADIUS Authentication server(s) should be configured with the relevant SU’s details (User Name and Password) and their corresponding services (see “Defining RADIUS Based Services” on page 236. BreezeMAX Modular Base Station System Manual 113 Chapter 4 - Operation and Administration When an SU attempt registering at the NPU, the NPU searches within its local database whether this is a Permanent SU (defined in the database by its MAC Address). If the NPU recognizes the SU as a Permanent one, it provides the Local (Permanent) Services as defined in the NPU's local database (see “Defining Local (Permanent) Services” on page 236. If the SU is not defined as Permanent in the NPU’s database, the NPU queries the RADIUS server for SU authentication and service provisioning. The RADIUS server searches for the corresponding Service defined for the SU (based on the User Name and Password). If it finds the applicable service(s) the RADIUS server replies to the NPU with the Service parameters (Service Profile Name, VLAN List, Access VLAN Configuration, VLAN Transparency Mode Option and VLAN Classification Mode). If the RADIUS server does not find matching SU’s credentials or defined service(s), it replies to the NPU with a reject message. According to the response from the RADIUS server, the NPU either authenticates the SU and provides the appropriate service(s) or rejects the SU. Part of the information sent from the RADIUS server can include the Authentication Time Out. Before the end of this time the NPU should re-authenticate the SU with the RADIUS server. This allows the operator to stop service for a customer even if the SU was not reset and the network entry process was not re-started. A RADIUS server can be used for authentication purposes only, for accounting purposes only, or for both authentication and accounting purposes. Up to two servers of each type can be defined. Each server of each type (Authentication/accounting) can be defined as either Primary or Secondary. Only one server of each type can be defined as Primary. If two servers of a certain type are defined, then upon first trial of an authentication/accounting transaction the NPU will attempt to communicate with the Primary server of the relevant type (provided the server’s Operation Status is Up). If it cannot communicate with the Primary server, it will attempt communicating with the other server (and vice versa). Upon succeeding to communicate with a certain server, this server is defined as Active (and the other one as Standby). As long as the NPU succeeds to communicate with an Active Authentication/Accounting server, it will continue using it for authentication/accounting transactions. 114 Operation Base Station Menu NOTE Upon switching to IP CS Switching Mode, all previous Ethernet CS Switching Mode Authentication and Accounting parameters are deleted from the database. Other changes that affect RADIUS configuration in IP CS Switching Mode include: a. Only one Authentication Server and one Accounting Server can be defined. The configurable Server Status and read-only Activity Status parameters are not applicable. b. Typically, the IP Addresses of the Authentication/Accounting Server(s) should be set to the IP address of the Data Port Default Gateway that serves as a proxy for the AAA server(s). The RADIUS menu includes three sub-menus: General Parameters Authentication Accounting 4.5.4.1 General Parameters The General Parameters menu enables viewing and modifying parameters that affect the communication with all RADIUS servers. These parameters include: Shared Secret Retry Interval (sec) Maximum Number of Retries Keep Alive Timeout (sec) 4.5.4.1.1 Shared Secret Shared Secret is the key used for encrypting the User name and Password transmitted to the RADIUS server(s). For security and control reasons, the Shared Secret option is available only for users with Administration access rights, using the Administrator Password to access the program. The Shared Secret cannot be changed using SNMP. For the same security reasons, the Shared Secret is displayed as a series of asterisks, and when defining it for the first time or updating it, the user is prompted to re-enter the new Shared Secret for confirmation. BreezeMAX Modular Base Station System Manual 115 Chapter 4 - Operation and Administration NOTE For security reasons, the Shared Secret does not change after performing the Set Factory Defaults operation. For the same reason, the Shared Secret cannot be configured using SNMP and it is not included in backup configuration files. Valid Shared Secret: Up to 16 printable characters, case sensitive. The default Shared Secret is null (Shared Secret must be defined). 4.5.4.1.2 Retry Interval (sec) The Retry Interval parameter defines the time in seconds to wait before retransmitting a RADIUS message if no response is received. The range is 1-5 (seconds). The default value is 5 (seconds). 4.5.4.1.3 Maximum Number of Retries The Maximum Number of Retries parameter defines the maximum number of retransmission attempts, before a decision is taken to revert to another server if configured, or give up. The range is 0-5 (retries). The default value is 3 (retries). 4.5.4.1.4 Keep Alive Timeout (sec) The NPU maintains a keep alive mechanism with all defined servers. The Keep Alive Timeout defines the time in seconds to wait before reaching a decision that a certain server is no longer available. The range is 60-180 (seconds). The default value is 60 (seconds). NOTE When the NPU sends keep alive message to the server, it uses it's own default User Name and User Password. These User Name and User Password must be configured in the users list (the same list used for the SUs) of the server, otherwise the server will response with a reject message. The default User Name of the NPU is: KeepAliveUserNameAndPassword. The default User Password of the NPU is: KeepAliveUserNameAndPassword The default User Name and User Password of the NPU are not configurable. 116 Operation Base Station Menu 4.5.4.2 Authentication The Authentication menu enables viewing the status and parameters of defined Authentication servers, adding a new server (up to a maximum of two), or deleting a server from the database. The parameters of an existing server cannot be updated: to modify the parameters of a server, it must first be deleted and then defined again through the Add Server option. The Authentication menu includes the following options: Show All Add Server Select Server 4.5.4.2.1 Show All Select this option to view the current status and parameters of all defined Authentication servers. For each defined Authentication server the following details are displayed: IP Address UDP Port Server Status: Primary or Secondary Operation Status: Up or Down (according to the keep alive mechanism) Activity Status: Active or Standby (indicates whether this is the server currently in use for authentication purposes) 4.5.4.2.2 Add Server Select this option to define a new Authentication server. Up to two Authentication servers can be defined. You will be prompted to configure the following parameters: 4.5.4.2.2.1 IP Address The IP address of the Authentication server. The default is null (IP address must be defined). Refer to the limitations described in “IP Addresses Configuration” on page 94. BreezeMAX Modular Base Station System Manual 117 Chapter 4 - Operation and Administration 4.5.4.2.2.2 UDP Port Specifies the UDP port number used by the RADIUS server for authentication transactions. Valid values: 1 to 65535. The default value is 1812 (RFC 2865 requirement). 4.5.4.2.2.3 Server Status Defines whether this server is Primary or Secondary. Each Authentication server can be defined as either Primary or Secondary. Only one Authentication server can be defined as Primary. 4.5.4.2.3 Select Server This option enables selecting an existing Authentication for viewing its status and parameters, deleting it from the database or viewing its Statistics counters. The selection is based on the server's IP address. The available options are: Show: Displays current status and parameters. For information on displayed details refer to Section 4.5.4.2.1), Delete: To delete the server from the database Statistics: To display or reset the Statistics Counters for this server. The Statistics Counters display traffic information according to the standard RFC 2618 "RADIUS Authentication Client MIB”, as follows: Round Trip Time: The time interval (in hundredths of a second) between the most recent Access-Reply/Access-Challenge and the Access-Request that matched it from this server. Access Requests: The number of RADIUS Access-Request packets sent to this server. This does not include retransmissions. Access Retransmissions: The number of RADIUS Access-Request packets retransmitted to this server. Access Accepts: The number of RADIUS Access-Accept packets (valid or invalid) received from this server. Access Rejects: The number of RADIUS Access-Reject packets (valid or invalid) received from this server. 118 Operation Base Station Menu Access Challenges: The number of RADIUS Access-Challenge packets (valid or invalid) received from this server. Malformed Access Responses: The number of malformed RADIUS Access-Response (Access-Accept, Access-Challenge or Access-Reject) packets received from this server. Malformed packets include packets with an invalid length. Bad authenticators or Signature attributes or unknown types are not included. Bad Authenticators: The number of RADIUS Access-Response packets containing invalid authenticators or Signature attributes received from this server. Pending Requests: The number of RADIUS Access-Request packets destined for this server that have not yet timed out or received a response. This counter is incremented when an Access-Request is sent and decremented due to receipt of an Access-Accept, Access-Reject or Access-Challenge, a timeout or retransmission. Timeouts: The number of authentication timeouts to this server. After a timeout the client may retry to the same server, send to a different server, or give up. A retry to the same server is counted as a retransmit as well as a timeout. A send to a different server is counted as a Request as well as a timeout. Unknown Types: The number of RADIUS packets of unknown type which were received from this server on the authentication port. Packets Dropped: The number of RADIUS packets of which were received from this server on the authentication port and dropped for any reason. 4.5.4.3 Accounting The Accounting menu enables viewing the status and parameters of defined Accounting servers, adding a new server (up to a maximum of two), or deleting a server from the database. The parameters of an existing server cannot be updated: to modify the parameters of a server, it must first be deleted and then defined again through the Add Server option. The Accounting menu includes the following options: Show All Add Server Select Server BreezeMAX Modular Base Station System Manual 119 Chapter 4 - Operation and Administration 4.5.4.3.1 Show All Select this option to view the current status and parameters of all defined Accounting servers. For each defined Accounting server the following details are displayed: IP Address UDP Port Server Status: Primary or Secondary Operation Status: Up or Down (according to the keep alive mechanism) Activity Status: Active or Standby (indicates whether this is the server currently in use for accounting purposes) 4.5.4.3.2 Add Server Select this option to define a new Accounting server. Up to two Accounting servers can be defined. You will be prompted to configure the following parameters: 4.5.4.3.2.1 IP Address The IP address of the Accounting server. The default is null (IP address must be defined). Refer to the limitations described in “IP Addresses Configuration” on page 94. 4.5.4.3.2.2 UDP Port Specifies the UDP port number used by the RADIUS server for accounting transactions. Valid values: 1 to 65535. The default value is 1813 (RFC 2866 requirement). 4.5.4.3.2.3 Server Status Defines whether this server is Primary or Secondary. Each Accounting server can be defined as either Primary or Secondary. Only one Accounting server can be defined as Primary. 4.5.4.3.3 Select Server This option enables selecting an existing Accounting for viewing its status and parameters, deleting it from the database or viewing its Statistics counters. The selection is based on the server's IP address. The available options are: 120 Operation Base Station Menu Show: Displays current status and parameters. For information on displayed details refer to Section 4.5.4.3.1), Delete: To delete the server from the database. Statistics: To display or reset the Statistics Counters for this server. The Statistics Counters display traffic information according to the standard RFC 2620 "RADIUS Accounting Client MIB”, as follows: Round Trip Time: The time interval (in hundredths of a second) between the most recent Accounting-Response and the Accounting-Request that matched it from this server. Requests: The number of RADIUS Accounting-Request packets sent to this server. This does not include retransmissions. Retransmissions: The number of RADIUS Accounting-Request packets retransmitted to this server. Retransmissions include retries where the Identifier and Acct-Delay have been updated, as well as those in which they remain the same. Response: The number of RADIUS packets received on the accounting port from this server. Malformed Responses: The number of malformed RADIUS Accounting-Response packets received from this server. Malformed packets include packets with an invalid length. Bad authenticators or unknown types are not included. Bad Authenticators: The number of RADIUS Accounting-Response packets containing invalid authenticators received from this server. Pending Requests: The number of RADIUS Accounting-Request packets sent to this server that have not yet timed out or received a response. This counter is incremented when an Accounting-Request is sent and decremented due to receipt of an Accounting-Response, a timeout or retransmission. Timeouts: The number of accounting timeouts to this server. After a timeout the client may retry the same server, send to a different server, or give up. A retry to the same server is counted as a retransmit as well as a timeout. A send to a different server is counted as an Accounting- Request as well as a timeout. Unknown Types: The number of RADIUS packets of unknown type which were received from this server on the accounting port. BreezeMAX Modular Base Station System Manual 121 Chapter 4 - Operation and Administration Packets Dropped: The number of RADIUS packets of which were received from this server on the accounting port and dropped for any reason. 4.5.5 Licenses The License feature enables managing the license(s) granted to CPEs with limited capabilities (“L model” CPEs) as well as the general Base Station licenses. In an “L model” CPE, the overall throughput (the aggregate downlink and uplink MIR in all services allocated to subscribers behind the CPE) is limited to 2 Mbps. The Network Service Provider may purchase from Alvarion a bank of CPE unlimited bandwidth licenses, and allocate licenses to selected L model CPEs on a need basis (refer to Section 4.10.7.3.9 for details on assigning a license to a selected CPE). Rather than granting licenses only to specific L model CPEs, the Network Service Provider may also purchase a Base Station unlimited bandwidth license to override the bandwidth limitations of all L model CPEs served by the Base Station. Note however, that such a license is local; once the CPE moves to another Base Station it does not retain to capability for unlimited bandwidth. On the other hand, once a CPE has been allocated with a specific license, this license is permanent and the CPE is no longer identified as an L model CPE. The various licenses (CPEs Unlimited Bandwidth Licenses Bank, Base Station Unlimited Bandwidth License for all CPEs) are supplied as files to be loaded to the Base Station using TFTP. A license file can be loaded only to the Base Station specified in the applicable order. The Licenses menu enables viewing the current status of CPEs and Base Station Licenses. The available options are: Show CPEs License Bank Status Show Base Station Licenses Show Temporary Grace Licenses Show Grace Licenses Show License Log Show License Inventory Table 4.5.5.1 Show CPEs License Bank Status Select this option to view the current status of the CPEs Licenses Bank (if available). The displayed information includes: 122 Operation Base Station Menu License ID: The relevant license type. In the current version only a BW (Band-Width) license type is available. License Value: The specific details of the relevant licenses. In the current version all BW licenses are Unlimited. License Count: The number of currently available licenses (balance). Each time a license is granted to a specific CPE, the License Count is decremented by one. 4.5.5.2 Show Base Station Licenses Select this option to view the current Base Station Licenses (if applicable). The displayed information includes the License ID and License Value for each applicable license. Currently, the applicable license that may be available is Unlimited Bandwidth for all CPEs (License ID = BW, License Value = Unlimited). 4.5.5.3 Show Temporary Grace Licenses and Show Grace Licenses The aggregate uplink and downlink MIR in all the services allocated to an L model CPE should not exceed 2 Mbps. If the aggregate MIR in the services assigned to such a CPE exceeds this limit, the Network Service Provider has a 30 days grace period. During the grace period the assigned services are provided to the CPE. At any time during the 30 days grace period the Network Service Operator can load to the CPE the required permanent license for unlimited bandwidth. If a license was not loaded during this grace period, the following will happen: During the first 3 days, defined as a temporary grace period, the Network Service Provider may change the services assigned to the CPE so that the aggregate MIR is no longer above 2 Mbps. The CPE will be removed from the list of Temporary Grace Licenses and will return to its previous status. After the 3 days temporary grace period, the CPE is moved to the Grace Licenses list. After expiry of the full 30 days grace period, the CPE is moved to a list of “Grace Period Expired” CPEs (even if during the grace period the services assigned to them were changed so that the aggregate MIR is no longer above 2 Mbps). A CPE that was moved to the Grace Period Expired list will remain in this list for 3 months. A CPE that is included in this list cannot be cannot be granted another grace period. Any attempt to assign to it a service that will bring the aggregate MIR to a value above 2 Mbps will be rejected. The Show Temporary Grace Licenses option displays a table that includes the MAC addresses of CPEs that are currently included in the Temporary Grace BreezeMAX Modular Base Station System Manual 123 Chapter 4 - Operation and Administration License list. For each CPE the displayed list includes also the License ID (only BW license is applicable in the current version) and the expiration date of the temporary grace period. The Show Grace Licenses option displays a table that includes the MAC addresses of CPEs that are currently included in the Grace License list. For each CPE the displayed list includes also the License ID (only BW license is applicable in the current version) and the expiry date of the grace period. In addition, the Status of each entry is displayed. The possible Status options are: Grace Activated Warning Issued (3 days before expiry date) License Expired Local permanent (SU received a Local license) Permanent (SU received a Permanent license) 4.5.5.4 Show License Log The License Log contains the results of all trials to load a license file to the unit. The details displayed for each loading trial include the Date, Time, Load Status (Success Failure), File Name and Description. The Description for a successful operation is “License Loaded Successfully”. For a failed operation, the Description provides the reason for the failure. 124 Operation NPU Menu 4.6 NPU Menu The NPU menu includes the following options: Show Unit Control Configuration Performance Monitoring Following is a detailed description of these options. 4.6.1 Show Select this option to view the current value/selected option of configurable parameters. Refer to Section 4.6.3 for more details on these parameters. In addition, some general status information is shown, as follows: General Status Information: Serial Number HW Version HW Configuration Description Redundant CPLD Version (the Redundant CPLD is necessary to enable GPS support) Temperature (Celsius) Cumulative Power On Time (hours): The cumulative power-on time of the NPU since first power-up. Management Port Parameters and Status: Management Port MAC Address Management Port IP Address Management Port Subnet Mask Management Port Gateway BreezeMAX Modular Base Station System Manual 125 Chapter 4 - Operation and Administration Management Port Dest Subnet Management Port Dest Subnet Mask Management Port Status (Up/Down) Management Port Management Traffic (Enabled/Disabled) Data Port Parameters and Status: Data Port MAC Address Data Port IP Address Data Port Subnet Mask Data Port Gateway Data Port Management VLAN Data Port Speed Data Port Status (Up/Down) Data Port Management Traffic (Enabled/Disabled) Authorized Managers (per manager) details: IP Address Send Traps Read Community Write Community Voice (not applicable for units operating in IP CS Switching Mode): DRAP TTL Retries Bridge: Bridge Aging Time SW Files and Versions: Main SW File Main SW Version 126 Operation NPU Menu Shadow SW File Shadow SW Version Running From: The currently running version (Main or Shadow) Boot SW Version Frequency Bands File Version 4.6.2 Unit Control The Unit Control menu of the NPU enables changing the access Passwords and the Monitor Inactivity Timeout, resetting the NPU, reverting the Base Station and the NPU to the factory default configuration, managing the SW versions of the module and creating backup files. The Unit Control menu includes the following options: Change Password Reset Set Factory Defaults SW Versions Control Create Backup Monitor Inactivity Timeout 4.6.2.1 Change Password For security and control reasons, the Change Password option is available only for users with Administration access rights. The Change Password option enables defining the passwords for each of the three different access levels: Administrator, Installer and Monitor. After changing the password for a selected access level, you will be prompted to re-enter the new password for confirmation. NOTE For security reasons, the passwords do not change after performing the Set Factory Defaults operation. For the same reason, the passwords cannot be managed using SNMP and are are not included in backup configuration files. Valid passwords: Up to 16 printable characters, case sensitive. BreezeMAX Modular Base Station System Manual 127 Chapter 4 - Operation and Administration The default passwords are: Table 4-3: Default Passwords 4.6.2.2 Access Level Default Password Administrator admin Installer installer Monitor monitor Reset Unit Select this option to reset the NPU. To avoid unintentional reset, you will be prompted to confirm the reset request. Changes to some of the configurable parameters are applied only after reset. Refer to Section 4.12 for information on which parameters are changeable in run time and which changes are applied only after reset. 4.6.2.3 Set Factory Defaults Select this option to set the Base Station and NPU parameters (excluding the access Passwords) to their factory default values. The parameters will revert to their default values after the next reset. CAUTION Setting the parameters of the NPU to their default values will disable remote management of the Base Station since this affects the IP and Ethernet parameters and will delete all Authorized Managers. Refer to Section 4.12 for information on the factory default values of these parameters. 4.6.2.4 SW Version Control The NPU can contain two SW versions: Main: Each time the NPU resets it will reboot using the version defined as Main. Shadow: Normally the Shadow version is the backup version. Each time a new SW File is downloaded to the NPU, it will be stored as a Shadow version, replacing the previous Shadow Version. The typical process of upgrading to a new SW version includes the following steps: 128 Operation NPU Menu Download the new SW File to the NPU. It will be stored as the Shadow version. Reset and run the module from its Shadow version. Note that at this stage, if a reset were to occur, the NPU will return to the previous Main version. If you want to continue using the new version, swap the Shadow and Main versions. The new version is now defined as Main, and will be used each time the module reboots. The previous version is defined now as Shadow. Each SW version includes two identifiers: SW File, which is the name of the downloaded SW file. This name does not necessarily include clear identification of the SW version number. SW Version, which provides the SW version number. The SW Version Control submenu includes the following options: Show versions Run from Shadow Set as Main 4.6.2.4.1 Show Versions Select this option to view the current available versions and the running version: Main SW File Main SW Version Shadow SW File Shadow SW Version Running From: Main or Shadow Boot SW Version Frequency Bands File Version BreezeMAX Modular Base Station System Manual 129 Chapter 4 - Operation and Administration 4.6.2.4.2 Run from Shadow Select the Run from Shadow option to reset the NPU and run the Shadow version after power up. To avoid unintentional actions you will be prompted to confirm the request. 4.6.2.4.3 Set as Main When the NPU is running the Shadow version (after selecting Reset and Run from Shadow), it will boot from the Main version after the next reset. Select the Set as Main option if you want to swap versions so that the running version will become the Main version and will be the version to be used after reset. To avoid unintentional actions you will be prompted to confirm the request. 4.6.2.5 Create Backup The Create Backup option enables creating backup files of the Base Station configuration. The backup file contains copies of all the applicable configuration files and databases in the system. The following backup file types can be created: Full: The entire Base Station configuration (excluding Passwords and basic IP parameters of the MGMT and DATA ports - IP Address, Subnet Mask and Default Gateway). Profiles: All the profiles associated with services (Service Profiles, Forwarding Rules, Priority Classifiers, QoS Profiles). Profiles and Services: All the profiles and configurations associated with service (General Service parameters, Subscribers, Services, Service Profiles, Forwarding Rules, Priority Classifiers, QoS Profiles). This option is not applicable for units operating in IP CS Switching Mode. Filtering: All the configurations of Filtering Rules, Interface Filtering and MAC Address Deny List. This option is not applicable for units operating in IP CS Switching Mode. Traps: The configuration parameters for all traps. BS License File: All license related information, including total, available and used licenses, CPEs with allocated licenses (local or permanent), CPEs with grace or temporary grace licenses and CPEs for which grace license expired. 130 Operation NPU Menu Upon selecting the backup type option, you will be requested to confirm the request. After confirmation, a message is displayed indicating that the backup file creation is in process. Upon successful completion of the process, a completion message will be displayed. If a backup file of the same type already exists in the NPU, you will be asked whether to overwrite the existing file. If there was an error in the process of creating a backup file, an error message will be displayed, specifying the reason. To upload/download the Backup File: After the backup file has been created, it can be uploaded using a DOS based TFTP Client application to a target directory. To upload the file, use the command: tftp -i get . The default file name is: Full: backup.res. Profiles: profiles.res Profiles and Services: profiles_srvcs.res Filtering: filtering.res Traps: Traps_Config.res BS License File: BSLicense_ .res The file is encrypted and cannot be edited. However, it can be downloaded to other NPU(s) using a DOS based TFTP Client application with the command: tftp-i put . The target NPU will decrypt the backup file, extract all the configuration files and databases and will store them, replacing existing files/databases. The NPU should be reset to apply the downloaded configuration. NOTE To avoid loss of connectivity behind a router, the basic IP parameters of the MGMT and DATA ports (IP Address, Subnet Mask, Default Gateway) are not changed when loading a Full backup file to the NPU. The values of these parameters configured in the target NPU before the loading process, are maintained. BreezeMAX Modular Base Station System Manual 131 Chapter 4 - Operation and Administration 4.6.2.6 Monitor Inactivity Timeout The Monitor Inactivity Timeout parameter determines the amount of inactive time following which the unit automatically exits the Monitor program. The time out duration can range from 0 to 60 minutes. 0 means no inactivity timeout. The default value is 10 minutes. 4.6.3 Configuration The NPU Configuration menu enables viewing and updating parameters that define the functionality of the MGMT and DATA ports, the properties of authorized management stations and bridging functionality. It also enables configuring per Telnet session the types of messages that will be displayed upon occurrence of various events. The following are the guidelines for configuring these parameters: All IP parameters of both ports should be configured. Otherwise, default values will be used. The Destination Subnet parameters of the MGMT port enable defining an additional subnet of stations that can manage the device when connected via a router to the MGMT port. If OOB management via a router connected to the MGMT port is used, the parameters should be configured to ensure different subnets for the Data port, the Management port and the Management Port Destination Subnet. NOTE It is highly recommended to use the Management port for local management only. Typically the port should be down (disconnected). Authorized Manager(s) must be configured properly to enable remote management using AlvariSTAR (or another SNMP based application). The Configuration menu includes the following options: Management Port Data Port Authorized Managers 132 Operation NPU Menu Bridge Voice (not applicable for units operating in IP CS Switching Mode) Debug Stream 4.6.3.1 Management Port Parameters These parameters define the IP parameters for the Management (MGMT) port connecting the base station to the backbone. NOTE It is highly recommended to use the Management port for local management only. Typically the port should be down (disconnected). The Ethernet interface of the Management port in the NPU operates using Auto Negotiation, enabling communication at either 10 Mbps or 100 Mbps, Full Duplex. 4.6.3.1.1 Management Port IP Address The IP address of the Management port. The default is 10.0.0.1. Refer to the limitations described in “IP Addresses Configuration” on page 94. 4.6.3.1.2 Management Port Subnet Mask The Subnet mask of the Management port. The default is 255.255.255.0. In a binary representation (32 bits) the string must comprise a series of contiguous binary '1's starting from the MSB, followed by a series of contiguous binary '0's. 0.0.0.0 (all zeros, meaning “nothing”) and 255.255.255.255 (all ones, meaning "this address only") are illegal and will be rejected. NOTE The local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters), must differ from the local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters) and from the subnet that is used as the Static Route for remote management via the Management port (defined by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters). 4.6.3.1.3 Management Port Gateway The Gateway IP address of the Management port. BreezeMAX Modular Base Station System Manual 133 Chapter 4 - Operation and Administration The default is 0.0.0.0 (meaning no default gateway). Refer to the limitations described in “IP Addresses Configuration” on page 94 (except to the default 0.0.0.0 address that is permitted as it means no gateway). 4.6.3.1.4 Management Port Dest Subnet and Management Port Dest Subnet Mask The Destination Subnet parameters define a Static Route, which is an IP subnet of stations that can manage the device when connected via a router to the Management port. The Static Route is applicable only when remote management is enabled for both the Management and Data ports (i.e., when both Management Port Management Traffic Enable/Disable and Data Port Management Traffic Enable/Disable parameters are set to Enable). The default is 0.0.0.0. for both parameters (meaning no Static Route). In a binary representation (32 bits) the subnet mask must comprise a series of contiguous binary '1's starting from the MSB, followed by a series of contiguous binary '0's. NOTE The Management Port Gateway, Destination Subnet and Destination Subnet Mask are grouped together. Exiting the configuration process (e.g. by pressing the Esc key) after configuring just the first one or two parameters in this group will discard the changes made. The subnet that is used as the Static Route for remote management via the Management port (defined by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters) must differ from the local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters) and from the local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters). 4.6.3.1.5 Management Port Management Traffic Enable/Disable The Management Port Management Traffic Enable/Disable parameter allows enabling/disabling remote management traffic via a router connected to the Management port. This parameter does not affect management traffic via the local subnet defined by the Management Port IP Address and Management Port Subnet Mask. If remote management for the Management port is disabled, then the unit can be managed by any PC on any of the following subnets (provided the PC is defined as an Authorized Manager): A The local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters). B The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters). 134 Operation NPU Menu C Any subnet reachable via the default Gateway of the Data port (if Data Port Gateway is defined). If remote management is enabled for both the Data Port and the Management port, then the unit can be managed by any PC on any of the following subnets (provided the PC is defined as an Authorized Manager): A The local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters). B The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters). C Any subnet reachable via the default Gateway of the Data port (if Data Port Gateway is defined). D The Static Route subnet (defined by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters) reachable via the Gateway of the Management port. NOTE To prevent the undesired situation where remote management traffic is unintentionally disabled in both the Management and Data ports, the Data Port Management Traffic Enable/Disable parameter will be automatically forced to Enabled upon disabling the Management Port Management Traffic, and vice versa. The Management Port Management Traffic Enable/Disable parameter is available only in the Monitor program. It is not available when using SNMP. 4.6.3.2 Data Port Parameters These parameters define the IP and Ethernet parameters for the Data (DATA) port connecting the base station to the backbone. 4.6.3.2.1 Data Port IP Address The IP address of the Data port. The default is 1.1.1.3. Refer to the limitations described in “IP Addresses Configuration” on page 94. 4.6.3.2.2 Data Port Subnet Mask The subnet mask of the Data port. The default is 255.255.255.0. In a binary representation (32 bits) the string must comprise a series of contiguous binary '1's starting from the MSB, followed by a series of contiguous binary '0's. 0.0.0.0 (all zeros, meaning “nothing”) and 255.255.255.255 (all ones, meaning "this address only") are illegal and will be rejected. BreezeMAX Modular Base Station System Manual 135 Chapter 4 - Operation and Administration NOTE The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters), must differ from the local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters) and from the subnet that is used as the Static Route for remote management via the Management port (defined by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters). 4.6.3.2.3 Data Port Gateway The IP address of the default Gateway for the Data port. The default is 0.0.0.0 (meaning no default gateway). Refer to the limitations described in “IP Addresses Configuration” on page 94 (except to the default 0.0.0.0 address that is permitted as it means no gateway). 4.6.3.2.4 Data Port Management VLAN This parameter defines the VLAN ID for management frames via the Data port. If a value from 0 to 4094 is configured for the Management VLAN ID, then the device will accept management frames only if their VLAN tag is the same as this value. Available values are 0-4094 or null (empty) for No VLAN. The default is null (No VLAN). CAUTION The Data Port Management VLAN is updated in run-time (without reset). 4.6.3.2.5 Data Port Speed The speed of the Data port's Ethernet interface that operates always in full duplex mode. Auto negotiation is not supported. The available options are 100 Mbps and 1 Gbps. The default speed is 100 Mbps. 4.6.3.2.6 Data Port Management Traffic Enable/Disable The Data Port Management Traffic Enable/Disable parameter allows enabling/disabling remote management traffic via a router connected to the DATA port. This parameter does not affect management traffic via the local subnet defined by the Data Port IP Address and Data Port Subnet Mask. If remote management for the Data port is disabled, then the unit can be managed by any PC on any of the following subnets (provided the PC is defined as an Authorized Manager): A The local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters). 136 Operation NPU Menu B The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters). C Any subnet reachable via the Gateway of the Management port (if defined). Note that in this case the Static Route (if defined) is ignored, and the defined Gateway becomes the default Gateway, enabling remote management by any PC reachable via the Gateway. If remote management is enabled for both the Data Port and the Management port, then the unit can be managed by any PC on any of the following subnets (provided the PC is defined as an Authorized Manager): A The local subnet of the Management port (defined by the Management Port IP Address and Management Port Subnet Mask parameters). B The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask parameters). C Any subnet reachable via the default Gateway of the Data port (if Data Port Gateway is defined). D The remote Static Route subnet (defined by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters) reachable via the Gateway of the Management port. NOTE To prevent the undesired situation where remote management traffic is unintentionally disabled in both the Management and Data ports, the Management Port Management Traffic Enable/Disable parameter will be automatically forced to Enabled upon disabling the Data Port Management Traffic, and vice versa. The Data Port Management Traffic Enable/Disable parameter is available only in the Monitor program. It is not available when using SNMP. 4.6.3.3 Authorized Managers The Authorized Managers submenu enables defining the properties of management stations that are allowed to manage the Base Station using SNMP, including all its components and the SUs associated with it. NOTE If no Authorized Manager is defined in the device, it can be managed using SNMP by any station, with the default Read (public) and Write (private) Communities. If at least one Authorized Manager is defined, the device can be managed only by a station whose parameters match a defined Authorized Manager. The Authorized Manager submenu includes the following options: BreezeMAX Modular Base Station System Manual 137 Chapter 4 - Operation and Administration 4.6.3.3.1 Show All Select this option to view the details of all currently defined authorized managers. 4.6.3.3.2 Select This option enables selecting an existing authorized manager for viewing or updating its properties or for deleting it from the database. The selection is based on the authorized manager's IP address. Refer to the following Add section for details on the configurable parameters. 4.6.3.3.3 Add Select this option to add a new authorized manager. Up to 10 Authorized Manager can be defined. The following parameters can be configured: 4.6.3.3.3.1 IP Address The IP address of the Authorized Manager. Refer to the limitations described in “IP Addresses Configuration” on page 94. 4.6.3.3.3.2 Send Traps The Send Traps parameters whether to enable or disable sending of traps to the Authorized Manager. 4.6.3.3.3.3 Read Community The SNMP Read Community to be used by the Authorized Manager. A null Read Community means that the read (get) operation can only be performed using the Write Community. Valid Community strings: Up to 23 printable characters, case sensitive. 4.6.3.3.3.4 Write Community The SNMP Write Community to be used by the Authorized Manager. A null Write Community means that the Authorized Manager has Read only access rights. Valid Community strings: Up to 23 printable characters, case sensitive. 4.6.3.4 Bridge The Bridge submenu enables configuring the Bridge Aging Time parameter, setting the aging time for all addresses in the Forwarding Data Base. The available values are from 1 to 1440 minutes, or 0 for no aging. The default is 10 minutes. 4.6.3.5 Voice The Voice submenu enables configuring the DRAP TTL Retries parameter. This parameter sets the limit of TTL retries for gateways that support the DRAP 138 Operation NPU Menu protocol before concluding that the gateway is no longer active and removing it from the database. The TTL retry time (the maximum time between two consecutive Allocation Requests) is 255 seconds. The Voice option is not applicable for units operating in IP CS Switching Mode. The range is from 1 to 100. The default is 4. NOTE During SW download to a gateway, which may take up to almost 15 minutes under worst conditions, the DRAP protocol is not active. If the gateway is removed from the database before SW download is completed, the download process will fail. During SW download, the DRAP TTL Retries parameter should be set to its default value of 4 (equivalent to 17 minutes). 4.6.3.6 Debug Stream The Debug Stream submenu enables configuring the types of messages that will be displayed during the Telnet session upon the occurrence of various events. These messages are typically used for investigating various problem situations, and many of them are meaningful only to Alvarion’s technicians. The DS Class Enable and DS Class Disable options can be used to enable or disable various classes of messages. The classes of messages that can be controlled include: ERR: Error messages that should not occur under regular conditions. SYS: Indication of important events and alarms. TRAP: Text messages displaying the information supplied by relevant traps. The default for all classes is Disable. NOTE Enabling the display of selected classes is applicable only for the current Telnet session. These parameters affect only the session and are not stored in the device. Upon starting a new session, or after reseting the unit, all classes are disabled. 4.6.4 Performance Monitoring The Performance Monitoring option enables to view and reset the NPU Ethernet Ports counters. The Performance Monitoring submenu includes the following options: Data Port BreezeMAX Modular Base Station System Manual 139 Chapter 4 - Operation and Administration Management Port All counters 4.6.4.1 Data Port Counters The Data Port option enables viewing or resetting the Data (DATA) port counters. The information displayed for each counter is the accumulated number since the last time the counters were reset. The counters are reset each time the NPU is reset, or upon activating the Reset Counters option. The Data Port counters include: Data Port Rx Counters Total Packets Received: The total number of packets received on the interface. Packets with errors are not counted. Management Packets Forwarded: The total number of management packets (packets whose destination is the NPU, and broadcasts) received on the Data port and forwarded to the NPU's internal management. Packets Forwarded to Slot 1: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 1. Packets Forwarded to Slot 2: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 2. Packets Forwarded to Slot 3: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 3. Packets Forwarded to Slot 4: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 4. Packets Forwarded to Slot 7: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 7. Packets Forwarded to Slot 8: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 8. Packets Forwarded to Slot 9: The total number of packets received from the Data port and forwarded by the NPU to AU Slot 9. Packets Discarded on Rx: Packets received from the Data port that were discarded due to switching and classification failures. Data Port Tx Counters 140 Operation NPU Menu Total Packet Transmitted: The total number of packets transmitted to the interface. Packets with errors are not counted. Management Packets Submitted: The total number of management packets submitted by the NPU. Packets Submitted from Slot 1: The total number of packets received by the NPU from the AU in Slot 1 and submitted to the Data port. Packets Submitted from Slot 2: The total number of packets received by the NPU from the AU in Slot 2 and submitted to the Data port. Packets Submitted from Slot 3: The total number of packets received by the NPU from the AU in Slot 3 and submitted to the Data port. Packets Submitted from Slot 4: The total number of packets received by the NPU from the AU in Slot 4 and submitted to the Data port. Packets Submitted from Slot 7: The total number of packets received by the NPU from the AU in Slot 7 and submitted to the Data port. Packets Submitted from Slot 8: The total number of packets received by the NPU from the AU in Slot 8 and submitted to the Data port. Packets Submitted from Slot 9: The total number of packets received by the NPU from the AU in Slot 9 and submitted to the Data port. Packets Discarded on Tx: Always 0. Currently packets are not discarded on Tx. 4.6.4.2 Management Port Counters The Management Port option enables viewing or resetting the Management (MGMT) port counters. The information displayed for each counter is the accumulated number since the last time the counters were reset. The counters are reset each time the NPU is reset, or upon activating the Reset Counters option. The Management Port counters include: Packets Received Packets Discarded on Rx Packets Transmitted Packets Discarded on Tx BreezeMAX Modular Base Station System Manual 141 Chapter 4 - Operation and Administration 4.6.4.3 All Counters The All Counters option enables viewing or resetting both the Data (DATA) port and Management (MGMT) port counters. 142 Operation Radio Cluster Menu 4.7 Radio Cluster Menu Radio Cluster is a logical entity used to describe and support management of the Base Station's elements associated with specific geographical sectors. A Radio Cluster represents one or several ODUs that serve (through their directional antennas) the same geographical sector. Up to a maximum of six Radio Clusters can be defined per Base Station, representing a cell coverage using 6 x 60° antennas. The Radio Cluster(s) must be defined prior to defining the relevant ODU(s), AU(s) and AU Channel(s). The Radio Cluster menu includes the following options: Show Summary Select Add 4.7.1 Show Summary Select this option to view the current status of all defined Radio Clusters. For each defined Radio Cluster, the display includes the following information: ID: Radio Cluster ID (1-6) Name: The string that is used as the descriptive name of the Radio Cluster. Location: The string that is used as the descriptive location of the Radio Cluster. Sector Heading: The direction (angle from the north) of the geographical sector. Sector Beam Width: The beam width of the antenna(s) used in the geographical sector. BreezeMAX Modular Base Station System Manual 143 Chapter 4 - Operation and Administration 4.7.2 Select Use this option and select an already defined Radio Cluster to open the Radio Cluster # menu that will enable managing and configuring the selected Radio Cluster. The selected Radio Cluster # menu includes the following options: Show: Select this option to view the current values defined for the selected Radio Cluster's parameters. Update: Select this option to update one or more of the selected Radio Cluster's parameters. For details on the configurable parameters Refer to Section 4.7.4. Delete: Select this option to delete the selected Radio Cluster from the database. 4.7.3 Add Select this option to define a new Radio Cluster. For details on the configurable parameters refer to Section 4.7.4. 4.7.4 Radio Cluster Parameters 4.7.4.1 Radio Cluster ID A number used to identify the Radio Cluster. The Radio Cluster ID is configurable only when adding a new Radio Cluster. The available values range from 1 to 6. 4.7.4.2 Name A string of up to 32 printable characters used as the descriptive name of the Radio Cluster. This is an optional descriptive parameter. The default is an empty string. 4.7.4.3 Location A string of up to 255 printable characters used to describe the location of the Radio Cluster. This is an optional descriptive parameter. 144 Operation Radio Cluster Menu 4.7.4.4 Sector Heading The direction of the geographical sector, defined in degrees from the north. This is an optional descriptive parameter. The values range is from 0 to 359 (degrees from north). The default value is 0 (degrees from north). 4.7.4.5 Sector Beam Width The beam width, in degrees, of the antenna(s) used in the geographical sector. This is an optional descriptive parameter. The values range is from 0 to 359 (degrees). The default value is 90 (degrees). BreezeMAX Modular Base Station System Manual 145 Chapter 4 - Operation and Administration 4.8 ODU Menu The ODU(s) must be defined prior to defining the relevant AU(s) and AU Channel(s). The ODU menu includes the following options: Show Summary Select Add 4.8.1 Show Summary Select this option to view the current status of all defined ODUs. For each defined ODU, the display includes the following information: ID: ODU ID (1-24) Associated Radio Cluster: The ID (1-6) defined for the associated Radio Cluster. Configured Tx Power: The defined Tx Power in dBm units. ODU Configured Band: The radio band configured for the ODU. Associated to AU:Channel: The details of associated AU Slot ID and Channel Number (if any) Admin Status: Enabled or Disabled. For details on the parameters refer to Section 4.8.4. Upon first power-up of the Base Station, 7 ODUs are defined automatically, with ODU IDs from 1 to 7. The parameters of these automatically created ODUs are: Associated Radio Cluster: NA Tx Power: 28 dBm 146 Operation ODU Menu ODU Configured Band: Not Defined Admin Status: Enabled 4.8.2 Select Use this option and select an already defined ODU to open the ODU # menu that will enable managing and configuring the selected ODU. The selected ODU # menu includes the following options: 4.8.2.1 Show Select this option to view the current value/selected option of applicable parameters. In addition, some general status information is displayed, as follows: ID Associated Radio Cluster Configured Tx Power ODU Configured Band Associated to AU:Channel (if any) Admin Status Oper Status (applicable only for an associated ODU) HC08 Version (applicable only for an associated ODU) CPLD Version (applicable only for an associated ODU) Card Serial Number (applicable only for an associated ODU) Temperature (Celsius) (applicable only for an associated ODU) HW Revision (applicable only for an associated ODU) HW Configuration Description (applicable only for an associated ODU) BreezeMAX Modular Base Station System Manual 147 Chapter 4 - Operation and Administration Max Tx Power: The maximum Tx Power supported by the ODU. This read-only parameter sets the upper limit for the Tx Power parameter (applicable only for an associated ODU). Actual Tx Power: The actual Tx power, that may differ from the Configured Tx Power: If the configured value is below the minimum supported by the ODU the actual power will be set to the minimum supported by the unit. If the configured value is above the maximum supported by the ODU, the power will be changed to the maximum value supported by the unit (applicable only for an associated ODU). 4.8.2.2 Update Select this option to update one or more of the selected ODU's parameters. For details on the configurable parameters refer to Section 4.8.4. 4.8.2.3 Delete Select this option to delete the selected ODU from the database. 4.8.3 Add Select this option to define a new ODU. For details on the configurable parameters refer to Section 4.8.4. 4.8.4 ODU Parameters 4.8.4.1 ODU ID A number used to identify the ODU. The ODU ID is configurable only when adding a new ODU. The available values range from 1 to 24. 4.8.4.2 Associated Radio Cluster The ID of the associated Radio Cluster. The available values range from 1 to 6. The value must be that of an already defined Radio Cluster. 4.8.4.3 Configured ODU Frequency Band The Configured ODU Frequency Band will be modified through the use of Frequency Bands Configuration file (see Section 4.8.5). 148 Operation ODU Menu The available values are the list numbers from the displayed list of available Frequency Bands. The Configured ODU Frequency Band can be updated only if the ODU is not associated with any AU Channel, or if the Admin Status of the associated AU Channel is Disabled. Compatibility between the Configured ODU Frequency Band and its actual band is verified by the AU upon trying to associate the ODU with a Channel. If the Configured ODU Frequency Band differs from the actual band supported by the ODU, a mismatch trap will be sent by the AU upon trying to associate it with a Channel and the association will be rejected. 4.8.4.4 Tx Power The Tx Power parameter defines the power level of the transmitted signal at the antenna port of the ODU. The range is from 13 to 50 dBm using a 0.25 dBm resolution. If the entered value is not compatible with the installed ODU, a trap will be issued. If the entered value is below the minimum supported by the ODU the actual power will be set to the minimum supported by the unit. If the entered value is above the maximum supported by the ODU, the power will be changed to the maximum value supported by the ODU. The actually supported range is: 3.5 GHz units: 24 to 34 dBm. 2.x GHz units with HC08 version 134: 25 to 36 dBm. 2.x GHz units with HC08 version 137 (new ODU, HW ready for 10 MHz bandwidth): 30 to 36 dBm. The default is 28 dBm (will be automatically changed to 30 in new 2.x GHz units with HC08 version 137). If the Diversity Mode is set to Fourth Order Diversity, the Tx Power of the ODUs associated with Channels 2-4 will be forced to the value configured for the ODU associated with Channel 1. If the Diversity Mode is set to Second Order Diversity, the Tx Power of the ODU associated with Channel 2 will be forced to the value configured for the ODU BreezeMAX Modular Base Station System Manual 149 Chapter 4 - Operation and Administration associated with Channel 1. Channels 3 and 4 are not used in Second Order Diversity Mode. NOTE In sectors with diversity (either second or fourth order diversity), new 2.x GHz AU-ODUs with HC08 revision 137 (HW ready for 10 MHz bandwidth), cannot be connected to the same AU-IDU together with older AU-ODUs with HC08 version 134. All AU-ODUs connected to the same AU-IDU must use the same HC08 version. 4.8.4.5 Admin Status The transmit on/off status of the ODU. The default option is Disabled. 4.8.5 Frequency Bands File and Frequency Bands Groups The Frequency Bands Configuration file defines the characteristics of each of the frequency bands supported by the system. These characteristics include: Lowest Downlink Frequency Highest Downlink Frequency Step (resolution) Default Frequency Group ID: In certain cases, an AU can be connected to ODUs using different Frequency Bands. The Group ID defines the Frequency Bands Group, which includes all the Frequency Bands that can be used by the same AU. An AU cannot be associated with two or more ODUs that use Frequency Bands belonging to different Groups. In the current release, the following Frequency Bands are supported: Table 4-4: Frequency Bands ID Frequency Band Group (ID) Downlink Frequency Range Resolution Default Frequency (MHz) 12 2.3 2.3GHz (5) 2300-2360 MHz 125 KHz 2307.5 13 2.5A 2.5GHz (6) 2496-2602 MHz 125 KHz 2592.5 14 2.5B 2.5GHz (6) 2590-2690 MHz 125 KHz 2592.5 150 Operation ODU Menu Table 4-4: Frequency Bands ID Frequency Band Group (ID) Downlink Frequency Range Resolution Default Frequency (MHz) 15 3.4a 3.5GHz TDD (7) 3399.5-3455 MHz 125 KHz 3446.75 16 3.4b 3.5GHz TDD (7) 3445-3500 MHz 125 KHz 3446.75 17 3.5a (TDD) 3.5GHz TDD (7) 3500-3555 MHz 125 KHz 3551.75 18 3.5b (TDD) 3.5GHz TDD (7) 3545-3600 MHz 125 KHz 3551.75 19 3.3a 3.3GHz TDD (8) 3300-3355 MHz 125 KHz 3350 20 3.3b 3.3GHz TDD (8) 3345-3400 MHz 125 KHz 3350 Note that the Frequency Bands File includes additional Frequency Bands for systems that support FDD Duplex Mode or for future/other TDD systems that are not applicable to the current release. This mechanism allows adding new frequency bands without modifying the software by simply loading a new Frequency Bands File when the supporting hardware becomes available. The file will be either a part of the NPU's software or loaded later to the NPU, using an updated file obtained from Alvarion. BreezeMAX Modular Base Station System Manual 151 Chapter 4 - Operation and Administration 4.9 AU Menu The AU menu includes the following options: Show Summary SW Files in NPU Select Following is a detailed description of these options. 4.9.1 Show Summary Select this option to view the current status of all AUs. For each applicable slot (1-4, 7-9), the display includes the following information: AU Slot ID Status: Installed/Not Installed Fault Status: Fault/No Faults/Disconnected Configured SW File Name: The name of the AU SW File that should be used to upgrade an AU after being installed as well as after each reset. Should be either None (an empty string) or one of the AU SW Files available in the NPU. This is the SW File defined in the SW Versions Control of the AU (see Section 4.9.5.2.3). Configured SW Version: The SW Version of the Configured SW File described above. Configured Action: The operation to be performed with the Configured SW File when the AU is installed, as well as after each reset: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. This is the Action defined in SW Versions Control menu of the AU (see Section 4.9.5.2.3). SW Download Status (only for an installed AU): The status of the last SW download operation (or None). 152 Operation AU Menu Configured SU SW File Name: The name of the SU software file that should be used to upgrade an SU upon network entry for all SUs in this sector. (Not applicable to any SU whose Configured SW File Name is other than None). Should be either one of the SU SW Files available in the NPU or an empty string for None. Configured SU SW Version: The SW Version of the Configured SU SW File described above. Configured SU Action: The operation to be performed with the Configured SU SW File after network entry: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. Maximum Number of Voice Calls: The maximum number of voice calls that can be supported by the AU (not applicable for units operating in IP CS Switching Mode). Active Voice Calls (only for an installed AU, not applicable for units operating in IP CS Switching Mode): The number of currently active voice calls handled by the AU. AU IDU Type (only for an installed AU): The type of the AU-IDU module. The options are: Two Channels Four Channels Two Channels -HP Four Channels-HP The HP suffix indicates the AU-IDU is capable of supporting higher currents (up to 3.5 Ampers) of -54 VDC power supply from the PIU (via the IF cable) to each ODU. In the current release all AU-IDUs are Four Channels-HP. Operation Mode (only for an installed AU, not applicable for units operating in IP CS Switching Mode): The air protocol used by the AU. The defined operation modes are Standard (used in first generation BreezeMAX FDD systems) and Advanced Si (used in the WiMAX compatible TDD systems supporting Self BreezeMAX Modular Base Station System Manual 153 Chapter 4 - Operation and Administration Install SUs). In the current release only Advanced Si Operation Mode is applicable. For more details on SW File/Version and Operation refer to Section 4.9.5.2.3. 4.9.2 Upgrading AU’s SW To facilitate efficient upgrade of AU’s SW, two upgrade levels are available: AU level, for upgrading a single AU, described in Section 4.9.5.2.3.2 Base Station level, for upgrading all AUs in the Base Station, as described in the following section. 4.9.3 SW Files in NPU Up to four AU SW files can be stored in the NPU. Any of the available files can be loaded by the NPU to a selected AU. When four AU files are stored in the NPU, a new file cannot be added until at least one of the existing files is deleted. A default SW File Name and Default Action can be defined. These are the SW File and associated Action that will be used for a new AU after being installed, as well as after each reset. This feature simplifies the upgrade process, by defining the SW File and Action for all AUs. Two different pairs of Default SW File Name and Default Action may be defined, to optionally support AUs using either Standard Operation Mode or Advanced Si (Advanced - Self Install) Operation Mode. These Default SW File Name and Default Action are applicable to all AUs in the Base Station using the specified Operation Mode. However, they are not applicable for any AU whose Configured SW File Name (see Section 4.9.1) is other than None. This menu enables viewing the current AU SW files stored in the NPU and deleting selected file(s). It also enables defining the Default SW File Name and Default Action for each Operation Mode, and deleting the Configured SW Files in all AUs. 4.9.3.1 Show Files Select this option to display the AU SW files currently stored in the NPU, the Default SW Files and Default Actions. For each available SW file, the file name and the version are shown. 4.9.3.2 Default SW File (Standard) Select this option to define the Name of the SW File to be used for upgrading an AU using Standard Operation Mode after installation as well as after each reset, 154 Operation AU Menu and the Action to be taken with this file. Not applicable for any AU whose Configured SW File Name is other than None (see “SW File” on page 160) The Default SW File (Standard) option not applicable for units operating in IP CS Switching Mode. The Default SW File (Standard) parameters are: 4.9.3.2.1 Name The Name of the SW File to be used for upgrading an AU using Standard Operation Mode after installation as well as after each reset. Should be one of the AU SW Files currently stored in the NPU, or None (null). 4.9.3.2.2 Action The operation to be performed with the Default SW File (Standard) when an AU using Standard Operation Mode is installed, as well as after each reset: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. Refer to Section 4.9.5.2.3.2.2 for more details on these Actions. 4.9.3.3 Default SW File (Advanced Si) Select this option to define the Name of the SW File to be used for upgrading an AU using Advanced Si Operation Mode after installation as well as after each reset, and the Action to be taken with this file. Not applicable for any AU whose Configured SW File Name is other than None (see “SW File” on page 160) The Default SW File (Advanced Si) parameters are: 4.9.3.3.1 Name The Name of the SW File to be used for upgrading an AU using Advanced Si Operation Mode after installation as well as after each reset. Should be one of the AU SW Files currently stored in the NPU, or None (null). 4.9.3.3.2 Action The operation to be performed with the Default SW File (Advanced Si) when an AU using Advanced Si Operation Mode is installed, as well as after each reset: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. Refer to Section 4.9.5.2.3.2.2 for more details on these Actions. 4.9.3.4 Delete a File Select this option and enter the name of an existing AU SW file to delete it from the NPU's memory. 4.9.3.5 Clear All Configured AU SW Files Select this option to clear (delete) the AU Configured SW File in all AUs. BreezeMAX Modular Base Station System Manual 155 Chapter 4 - Operation and Administration 4.9.4 Select Use this option and select a slot to access the AU Slot # menu that will enable managing and configuring the AU in the selected slot, or pre-configuring the AU that will be installed in the slot at a later time. The available AU slot IDs are 1-4, 7-9. 4.9.5 AU Slot # Menu The AU Slot # menu enables managing and configuring the AU in the selected slot, or pre-configuring the AU that will be installed in the slot at a later time. The AU Slot # menu includes the following options: Show Unit Control Configuration Performance Monitoring 4.9.5.1 Show Select this option to view the current value/selected option of applicable parameters. In addition, some general status information is shown, as follows: General Status and Operation Parameters: IDU Serial Number IDU IF Card HW Revision IDU IF Card HW Configuration IDU Boot Version IDU Main Card HW Revision IDU Main Card HW Configuration IDU Temperature (Celsius) IDU Type Operation Mode (Standard or Advanced Si. Not applicable for units operating in IP CS Switching Mode) 156 Operation AU Menu Cumulative Power On Time (hours): The cumulative power-on time of the IDU since first power-up. Diversity Mode Minimum Allocation SW Files and Versions: Configured SW File Name Configured SW Version Configured Action Configured SU SW File Name Configured SU SW Version Configured SU Action Main SW File Name Main SW Version Shadow SW File Name Shadow SW Version Running From (Main or Shadow) MAC Parameters: Base Station ID (Operator ID, Cell ID, Sector ID) Operator ID (as defined in the Base Station-Cell menu) Cell ID (as defined in the Base Station-Cell menu) Sector ID Maximum Cell Radius (km) Actual Maximum Cell Radius (km) Multirate Parameters: Multirate Enable/Disable Uplink Basic Rate BreezeMAX Modular Base Station System Manual 157 Chapter 4 - Operation and Administration Downlink Basic Rate Minimum Number of Sub-Channels ATPC Parameters (as defined in the Base Station-Cell menu): ATPC Enable/Disable Optimal Uplink RSSI (dBm) NOTE The Optimal Uplink RSSI is configured at the Base Station level for all AUs. The permitted range for configuration is from -90 to -60 dBm. The actual range that can be accepted by AUs operating in TDD mode is -80 to -74 dBm. If a value higher than -74 dBm is configured at the Base Station level, the actual value in the AUs will be -74 dBm (hence the actual default at the AUs is -74 dBm). If a value lower than -80 dBm is configured at the Base Station level, the actual value in the AUs will be -80 dBm. If the configured value differs from the actual one, both will be shown, starting with the configured value. Voice Parameters (not applicable for units operating in IP CS Switching Mode): Maximum Number of Voice Calls Active Voice Calls 4.9.5.2 Unit Control The AU Unit Control menu enables resetting the AU and managing the SW versions of the module. The Unit Control menu includes the following options: Reset Set Factory Defaults SW Version Control 4.9.5.2.1 Reset Unit Select this option to reset the unit. To avoid unintentional reset, you will be prompted to confirm the reset request. Changes to some of the configurable parameters are applied only after reset. Refer to Section 4.12 for information on which parameters are changeable in run time and which changes are applied only after reset. 158 Operation AU Menu 4.9.5.2.2 Set Factory Defaults Select this option to set the AU parameters to their factory default values. Refer to Section 4.12 for information on the factory default values of these parameters. The parameters will revert to their default values after the next reset. 4.9.5.2.3 SW Versions Control The AU can contain two SW versions: Main: Each time the AU resets it will reboot using the version defined as Main. Shadow: Normally, the Shadow version is the backup version. Each time a new SW File is downloaded to the AU, it will be stored as a Shadow version, replacing the previous Shadow Version. The process of upgrading to a new SW version is controlled by the NPU, and is performed using one of the AU SW files installed in the NPU. If the specified AU SW file does not exist in the AU, it will be downloaded to the AU and the requested operation will be executed, as described below. If it already exists in the AU, then actual loading is not necessary. The following options are available in the SW Version Control menu: 4.9.5.2.3.1 Show Versions Select this option to view the following information: Versions in AU: Main SW File Name Main SW Version Shadow SW File Name Shadow SW Version Running From: Main or Shadow Configured AU SW Files: The configured AU SW File Name, Version and Action. Configured SU SW Files: The configured SU SW File Name, Version and Action. Available Versions in NPU: The available AU SW file names and the SW version of each file. BreezeMAX Modular Base Station System Manual 159 Chapter 4 - Operation and Administration 4.9.5.2.3.2 SW File Select this option to define the Name of the SW File to be used for upgrading the AU after installation as well as after each reset, and the Action to be taken with this file: 4.9.5.2.3.2.1 Name The Name of the SW File to be used for upgrading the AU after installation as well as after each reset. Should be one of the AU SW Files currently stored in the NPU, or None (null). 4.9.5.2.3.2.2 Action The operation to be performed with the SW File when the AU is installed, as well as after each reset: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main: None: Select None to cancel a pending request for another operation (an operation will be executed only after the next reset). Download: Select this option to download the specified SW File to the Shadow memory of the AU. If the file already exists in the AU, no action will take place. Run from Shadow: Select this option to download the specified SW File from the NPU to the Shadow memory of the AU, reset the AU and reboot using the Shadow version. Note that because the process is controlled by the NPU, the AU will continue running from the Shadow version after reset. If the specified file already exists as the Shadow version (meaning that previously a Download operation was executed for this SW File), the only actual operation to take place will be to reset and run from Shadow. If the specified file already exists as the Main version, no action will take place. Set as Main: Select this option to download the SW File from the NPU to the Shadow memory of the AU, reset the AU and reboot using the Shadow version, and then swap the Main and Shadow SW Version, so that the running version (which was previously the Shadow version) will become the Main version, to be used after next reset. If the specified file already exists as the running version and it is defined as the Shadow version (meaning that previously a Download and Run from Shadow operation was executed for this SW File), the only actual operation to take place will be to swap the Main and Shadow versions. If it is already defined as the Main version, no action will take place. 160 Operation AU Menu 4.9.5.2.3.3 SU SW File Select this option to define the Name of the SW File to be used for upgrading the SUs served by this AU after network entry, and the Action to be taken with this file. Not applicable for any Permanent SU whose Configured SW File Name is other than None (see Section 4.10.7.2.4.2) The SU SW File parameters are: 4.9.5.2.3.3.1 Name The Name of the SW File to be used for upgrading the SUs served by this AU. Should be one of the AU SW Files currently stored in the NPU, or None (null). 4.9.5.2.3.3.2 Action The operation to be performed with the SU SW File: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. Refer to Section 4.10.7.2.4.2.2 for more details on these Actions. 4.9.5.2.3.4 Clear All Configured SU SW Files for this AU Select this option to clear (delete) the SU Configured SW File in all Permanent SUs served by this AU. 4.9.5.3 Configuration The AU Configuration menu enables viewing and updating the AU's parameters. It is important to note that changes to some parameters take effect only after reset. For these parameters, the applicable Show menus display the Current as well as the Configured value. The Configuration menu includes the following options: MAC Phy Multi Channel Multirate Voice Parameters 4.9.5.3.1 MAC Parameters The MAC menu enables viewing/updating the following parameters: BreezeMAX Modular Base Station System Manual 161 Chapter 4 - Operation and Administration 4.9.5.3.1.1 ID Parameters The Operator ID, Cell ID and Sector ID constitute together the Base Station ID, which is the unique identifier of the AU. An SU can be authenticated by the AU only if its defined parameters match the Base Station ID configured for the AU. The Operator ID and Cell ID are defined for the Base Station (see Section 4.5.2.5) and are used by all AUs in the Base Station. In the AU's MAC Parameters menu they are available only in the Show option. The Sector ID parameter consists of three digits in the range of 0 to 255. The default Sector ID is 206. Changes in Sector ID are applied only after reset. 4.9.5.3.1.2 Maximum Cell Radius The Maximum Cell Radius is used to adapt various timing parameters of the MAC to the time it takes a message to reach its destination. This time delay is dependent upon the distance between the originating and receiving units. The timing parameters should be adapted to the largest expected delay, which is determined from the distance from the AU of the farthest SU served by it. NOTE For Non-Line-Of-Sight (NLOS) links using refractions, the cell distance should be higher than the line-of-sight distance. Typically a 10% margin is a good estimate for the increase in distance due to the NLOS operation. The basic time element (symbol) used by a system operating in TDD mode is 68 microseconds for a bandwidth of 3.5 MHz and 50 microseconds for a bandwidth of 5 MHz. This symbol size is translated to a round trip delay of approximately 20 km for 3.5 MHz bandwidth and 15 km for 5 MHz bandwidth, or a cell radius of 10 km or 7.5 km, respectively. NOTE An SU located at a distance larger than the Maximum Cell Radius will be rejected during the network entry process. The values range for the Maximum Cell Radius is from 10 to 50 km for a bandwidth of 3.5 MHz, and 7 to 45 km for a bandwidth of 5 MHz (representing a maximum delay of 6 symbols). 162 Operation AU Menu NOTE The actual value that the system will use is a multiple of the the one-way delay for a single basic time element: N*10 km for a bandwidth of 3.5 MHz or N*7.5 km for a bandwidth of 5 MHz, where N is a an integer from 1 to 6. The value configured for the Maximum Cell Radius will be up-rounded to the nearest applicable value. The read-only Actual Maximum Cell Radius (km) parameter in the Show option is the actual value used by the AU, that may differ from the configured value. The default is 20 km. 4.9.5.3.2 Phy Parameters The Phy menu enables viewing/updating the Bandwidth parameter: 4.9.5.3.2.1 Bandwidth The frequency bandwidth used by the radio. A change in the Bandwidth parameter will take effect only after resetting the AU. The Admin Status of all Channels belonging to the same AU must be disabled to enable a configuration change in the Bandwidth parameter. The available options are: 1 - 1.75 MHz 2 - 3.5 MHz 3 - 5.0 MHz 4 - 7 MHz 5 - 10 MHz The current Bandwidth values applicable for systems operating in TDD Mode are 3.5 MHz and 5 MHz. The AU will reject any selection of a Bandwidth not supported by it. The default is 3.5 MHz. 4.9.5.3.3 Multi Channel Parameters Each AU can include up to 4 Channels with Channels IDs from 1 to 4, corresponding to up to 4 ODU connectors. Each ODU connector (channel) can be connected to an ODU. The Multi Channel menu includes the following options: Show Summary Diversity Mode Select BreezeMAX Modular Base Station System Manual 163 Chapter 4 - Operation and Administration Following is a description of these options: 4.9.5.3.3.1 Show Summary Select this option to view the following information for each Channel: Channel (1-4) Associated ODU Downlink (Tx) Frequency (MHz) Uplink (Rx) Frequency (MHz): Applicable only to Channels associated with a defined ODU. Computed using the rules defined in the Frequency Bands Configuration File. In TDD systems the Uplink Frequency is the same as the Downlink Frequency. Admin Status (Enabled/Disabled) Configured Tx Power: Applicable only to Channels associated with a defined ODU. The Tx Power in dBm configured in the ODU. Associated Radio Cluster: Applicable only to Channels associated with a defined ODU. The Associated Radio Cluster defined in the ODU. Upon first power-up of the Base Station, the channels are defined automatically, as follows: Associated ODU: Channel 1 of all AUs is automatically associated with an ODU: Table 4-5: Automatic Association of Channel 1 Upon First Power-Up 164 AU Slot ID ODU ID AU Slot 1 AU Slot 2 AU Slot 3 AU Slot 4 AU Slot 7 AU Slot 8 AU Slot 9 Operation AU Menu For all other Channels (2-4) the Associated ODU is NA. Downlink (Tx) Frequency (MHz): 3551.750 Admin Status: Enabled for Channel 1, Disabled for all other Channels (2-4). 4.9.5.3.3.2 Diversity Mode The Diversity Mode of the AU. For details on diversity modes refer to “Base Station Radio Configurations” on page 8. The available options are: 1 - No Diversity 2 - Second Order Diversity 3 - Fourth Order Diversity for NLOS 4 - Fourth Order Diversity for LOS and NLOS Each of the Fourth Order Diversity modes uses a different downlink diversity scheme optimally adapted to the different propagation conditions prevailing in the relevant deployment scenario. Fourth Order Diversity for NLOS should typically be used when all or most of the SUs operate in Non-Line-Of-Sight (NLOS) conditions (typical to CPE Si units). Fourth Order Diversity for LOS and NLOS mode will provide better overall performance in deployments where there are SUs operating in both Line-Of-Sight (LOS) conditions (expected for most CPE-PRO S units) and Non-Line-Of-Sight (NLOS) conditions. The default is No Diversity. NOTE A change in the Diversity Mode parameter takes effect immediately and automatically resets the AU. It also disables the Admin Status of all its channels when changing from No Diversity to Second Order/Fourthe Order Diversity and vice versa. When changing from Fourth Order Diversity to Second Order Diversity, it disables the Admin Status of Channels 3 and 4. 4.9.5.3.3.3 Select Use this option to select a Channel ID (1-4) to open the Channel # menu for viewing or updating the Channel's parameters. The configurable Channel parameters are: Associated ODU: An ODU ID (1-24) of an already defined ODU. Downlink (Tx) Frequency (MHz): The Tx frequency in MHz, which must be in accordance with the selected Bandwidth (see Section 4.9.5.3.2.1) and the rules BreezeMAX Modular Base Station System Manual 165 Chapter 4 - Operation and Administration defined in the Frequency Bands File for the frequency band selected as the Configured ODU Frequency Band of the associated ODU (see Section 4.8.4.3). The help text (displayed upon clicking the Tab key) reflects the limitations imposed by these rules. In addition, the following rules must be followed in No Diversity mode if more than one channel is used: After configuring the Downlink Frequency f1 for one of the AU's Channels, the Downlink Frequencies for other Channels of the same AU should be configured using increments of +/- 0.875 MHz from the defined frequency: f1 +/-(N*0.875). The Downlink Frequencies of all Channels of the same AU should belong to the same Frequency Bands Group (see Section 4.8.5). Admin Status: The Admin Status must be disabled to enable changes in the Configured ODU Frequency Band of an associated ODU. If the Configured ODU Frequency Band differs from the actual band supported by the ODU, a mismatch trap will be sent by the AU upon trying to associate it with a Channel and the association will be rejected. The Admin Status of all Channels belonging to the same AU must be disabled to enable a configuration change in the Bandwidth parameter. If the Diversity Mode is set to Fourth Order Diversity, the Downlink (Tx) Frequency and Admin Status of Channels 2-4 are not configurable: they are set automatically to the same values configured for Channel 1. The Tx Power of the ODUs associated with Channels 2-4 will be forced to the value configured for the ODU associated with Channel 1. If the Diversity Mode is set to Second Order Diversity, the Downlink (Tx) Frequency and Admin Status of Channel 2 are not configurable: they are set automatically to the same values configured for Channel 1. The Tx Power of the ODU associated with Channel 2 will be forced to the value configured for the ODU associated with Channel 1. Channels 3 and 4 are not used in Second Order Diversity Mode. The Show menu includes also the following read-only parameters: Tx Power: The Tx Power of the Associated ODU. If the actual value differs from the configured one, both values will be displayed (starting with the configured value). 166 Operation AU Menu Associated Radio Cluster: As configured in the Associated ODU. Uplink (Rx) Frequency: Computed from the configured Downlink (Tx) Frequency according to the Duplex Separation of the applicable Frequency Band. In TDD systems the Uplink (Tx) Frequency is the same as the Downlink (Tx) Frequency. ODU Frequency Band: The ODU Frequency Band. If there is a mismatch between the Configured ODU Frequency Band and its actual band, both values will be displayed. Operational Status 4.9.5.3.4 Multirate Parameters BreezeMAX employs a multirate algorithm to dynamically adapt the modulation scheme and Forward Error Correction (FEC) coding to actual link conditions. The algorithm is managed by the AU taking into account also information received from the served SUs. Optimal values are calculated separately for the uplink and downlink for each SU. MAP messages transmitted to the SUs include information on the uplink rate that should be used by each SU for its next transmission. The multirate algorithm optimizes the trade-off between capacity and error rate: In most deployments, most of the links use high order modulation most of the time, maximizing capacity. “Bad” links use lower order modulation, maximizing availability. The algorithm provides independent adaptation per SU, and it is performed independently for UL and DL, based on link quality information (Burst Error Rate, SNR). The algorithm provides dynamic adaptation - modulation can be changed on a per burst basis. UL transmission rate is determined by the AU, and DL transmission rate is determined by the SU. The multirate algorithm in the uplink adapts dynamically both the modulation and the number of sub-channels to be allocated to each SU. When the Multirate algorithm is disabled, communication with connected SUs will continue using the last uplink and downlink rates selected by the Multirate algorithm. The Set Rates option in the SU (see Section 4.10.7.3.4.2), which becomes available only when the Multirate algorithm is disabled in the AU, enables setting the Uplink Current Rate and the Downlink Current Rate to any of the values listed in Table 4-6. The multirate algorithm chooses dynamically between several rates. These are also the rates that can be configured for the Basic Rate parameters. BreezeMAX Modular Base Station System Manual 167 Chapter 4 - Operation and Administration Table 4-6: Rates (Modulation Schemes and Coding) No. Rate BPSK 1/2 BPSK 3/4 (not applicable for TDD systems) QPSK 1/2 QPSK 3/4 QAM16 1/2 QAM16 3/4 QAM64 2/3 QAM64 3/4 NOTE Rate 2 (BPSK 3/4) is not applicable to systems operating in TDD mode.. The Multirate menu enables viewing/updating the following parameters: 4.9.5.3.4.1 Multirate Enable/Disable The Multirate Enable/Disable parameter controls whether the multirate algorithm should be used to determine current optimal rates in both the uplinks and the downlinks. The default is Enable. NOTE The multirate algorithm should always be enabled. The option to disable it is available to enable using a fixed rate to support certain tests. After each reset, the AU boots with the multirate enabled, disregarding its status before the device was reset. 4.9.5.3.4.2 Uplink Basic Rate The Uplink Basic Rate is the minimum rate to be used by the Multirate algorithm in all uplinks. This is also the rate to be used by SUs for non-scheduled transmissions, such as during the contention period. The Uplink Basic Rate is also the initial rate to be used by the algorithm for each new SU that joins the cell when the Multirate algorithm is enabled. The default rate is the lowest rate BPSK 1/2 (rate 1). 168 Operation AU Menu 4.9.5.3.4.3 Minimum Number of Sub-Channels The system supports Sub-Channelization (OFDMA) in the uplink, providing two advantages: Ability to connect SUs with relatively poor link conditions: reducing the amount of uplink sub-channels from 16 (full bandwidth) to 8, 4, 2 or 1 sub-channels enables increasing the maximum transmit power of the SU by 3, 6, 9 or 12 dBm, respectively. Better utilization of uplink capacity, by enabling several SUs to share the bandwidth at the same time. The available options are 1, 2, 4, 8, and 16 (full bandwidth) sub-channels. A value of 16 means that sub-channelization is disabled. The default is 1 sub-channels (full OFDMA support). Changes in Minimum Number of Sub-channels are applied only after reset. 4.9.5.3.4.4 Downlink Basic Rate The Downlink Basic Rate is the minimum rate to be used by the Multirate algorithm in all downlinks. This is also the rate to be used for downlink broadcasts and multicasts. Multicasts and broadcasts are sent to multiple recipients with different link qualities. Therefore, it is preferable to use a relatively low rate for these transmissions, thus reducing the probability of errors and increasing the likelihood that all intended recipients will receive them properly. This is also the initial rate to be used by the algorithm for each new SU that joins the cell when the Multirate algorithm is enabled. The default rate is the lowest rate BPSK 1/2 (rate 1). 4.9.5.3.5 Voice Parameters 4.9.5.3.5.1 Maximum Number of Voice Calls The Maximum Number of Voice Calls parameter sets the upper limit of simultaneous voice calls that will be supported by the AU. This parameter is applicable only to DRAP based voice calls, and is not applicable for units operating in IP CS Switching Mode. The range is from 0 to 300 Voice Calls. The default is 50. 4.9.5.3.5.2 AU Minimum Allocation The AU Minimum Allocation parameter defines the minimum allocation of symbols in the uplink: 5 symbols for typical data only services, or 3 symbols for BreezeMAX Modular Base Station System Manual 169 Chapter 4 - Operation and Administration deployments with significant VoIP traffic. A minimum allocation of 3 symbols can provide a higher capacity for VoIP calls, with a reduced overall throughput for data services. The options are 5 Symbols (the default) or 3 Symbols. NOTE In most deployments with both VoIP and Data services it is recommended to use the default 5 Symbols minimum allocation. Consult with Alvarion’s experts whether to use 3 Symbols minimum allocation in certain sectors, according to the specific traffic that should be supported. AU Minimum Allocation can be changed only via the Monitor program (not available via SNMP). 4.9.6 Performance Monitoring The AU Performance Monitoring menu includes the following options: Ports Counters BER Test Burst Error Rate Counters 4.9.6.1 Ports Counters The Ports Counters option enables viewing or resetting the Back Plane and Wireless ports counters. The information displayed for each counter is the accumulated number since the last time the counters were reset. The counters are reset each time the AU is reset, or upon activating the Reset option. NOTE The Back-Panel port of the AU is the internal Ethernet port between the AU and the NPU. The counters describe the traffic at the Back Plane and Wireless ports, as follows: Back Plane Port Counters Data Bytes Received: The total number of data bytes received from the Back Plane (NPU). Management frames and frames with errors are not included. Data Bytes Discarded on Rx: The number of bytes in packets discarded due to communication errors between the AU and the NPU. 170 Operation AU Menu Data Bytes Transmitted: The total number of data bytes transmitted to the Back Plane (NPU). Management frames and frames with errors are not included. Data Bytes Discarded on Tx: This count is always 0 (No discards). Wireless Port Counters Data Bytes Received: The total number of data bytes received from the Wireless link. MAC management frames and frames with errors are not included. Data Bytes Discarded on Rx: The number of bytes in packets received from the Wireless link and discarded due to MAC protocol receive errors, such as duplicate sequence number, wrong sequence number etc. (not CRC errors). Data Bytes Transmitted: The total number of data bytes transmitted to the Wireless link. MAC Management frames and frames with errors are not included. Data Bytes Discarded on Tx: The number of bytes in packets discarded due to congestion in the wireless medium. 4.9.6.2 BER Test This feature is not supported by the current version. 4.9.6.3 Burst Error Rate Counters The Burst Error rate Counters option enables selecting a specific SU by its MAC address for viewing or resetting the Burst Error Rate counters for the applicable downlink. The information displayed for each rate in the uplink is the accumulated number since the last time the counters were reset. The downlink counters can be viewed in the applicable SU menu. For each rate the displayed information (for the uplink) includes: Total Burst Error Bursts Error Rate The counters are reset each time the AU is reset, or upon activating the Reset option. BreezeMAX Modular Base Station System Manual 171 Chapter 4 - Operation and Administration 4.10 SU Menu The SU menu includes the following options: Show Summary Show Summary by AU SW Files in NPU Select by Name Select by MAC Address Add (not applicable for devices operating in IP CS Switching Mode) Clear All Configured SU SW Files Following is a detailed description of these options. 4.10.1 Show Summary Select this option to view summary information and main details for all connected and pre-configured SUs. For each SU, the following information is displayed: MAC Address User Name SU Type: ¾ CPE (first generation CPE. Not applicable in TDD systems) ¾ CPE PRO ¾ CPR PRO-L ¾ CPE PRO2 ¾ CPE PRO2-L ¾ CPE SI ¾ CPE SI-L (not applicable in current release) 172 Operation SU Menu ¾ CPE SI2 ¾ CPE-SI2-L (not applicable in current release) CPE PRO, CPE PRO-L, CPE SI and CPE SI-L use first generation Intel's Pro/Wireless 5116 WiMAX chip. CPE PRO2, CPE PRO2-L, CPE SI2 and CPE SI2-L use second generation (IEEE 802.16e-ready) WiMAX chip. The “L” suffix indicates that the SU was supplied with limited capabilities (limited bandwidth). Connected AU Slot ID SUID (an ID allocated to each SU by the connected AU) Registration Status (In Service, Out Of Service) Configured SW File Name: The SW File configured in the NPU (together with the Configured Action). Configured SW Version: The SW Version of the SW File configured in the NPU. Configured Action: The operation to be performed with the Configured SW File when the SU is connected, as well as after each reset: Null (do not load), Load (load to Shadow), Run from Shadow or Set as Main. SW Download Status: The status of the last SW download operation (or None). SU Status (Permanent or Temporary). This parameter is not applicable for units operating in IP CS Switching Mode, where the Status is always Temporary. SU IDU Type: Normal (Basic Universal IDU) or IDU-NG-4D1W (not applicable for units operating in IP CS Switching Mode). Number of Gateways: The number of Alvarion Gateways connected to the SU (including IDU-NG-4D1W, if exists). Not applicable for units operating in IP CS Switching Mode Service Fault Status: OK or reason for denying services to the SU. The reason can be: Loop problem. A loop was detected on the Ethernet side of the SU. An rbNetworkingError Trap will be sent, and services to this SU will be denied until resetting the SU from the network (NPU) side (provided the problem no longer exists). The problem is detectable through periodical (every 5 seconds) transmissions to the Ethernet link of SNAP packets BreezeMAX Modular Base Station System Manual 173 Chapter 4 - Operation and Administration with "AA AA 03" in the header, and the destination MAC address is 00:10:E7:00:00:01. If the SU receives this packet from the Ethernet, it means that there is a loop and the SU will send an appropriate message to the NPU. NOTE Another loop avoidance mechanism that is transparent to the operator is performed by the NPU: The NPU scans packets received from the network (DATA port) and verifies that the SRC MAC in the received packet does not match any of the addresses in the NPU's bridging table. If there is a match it means that the source MAC address of the message received from the network side is identical to a MAC address of a device behind one of the SUs served by the Base Station. In case of a match, the NPU discards all packets designated to the device with this MAC address, until it's aging time expires. Duplicate SU Name: The SU Name (User Name) is already in use by another SU connected to the same Base Station. A Base Station cannot serve two SUs with the same User Name. Upon identifying an SU with an SU Name (User Name) that is identical to that of a previously registered SU, the new SU will be registered (to enable management), but will not receive any services. Its name in the NPU database will be changed to SU@ . The system administrator will be informed of the problem through the Fault Status parameter in any of the relevant Show menus (Fault Status 2) and through a trap message (rbSuDuplicateName trap). If the administrator decides that the SU is legitimate and should receive services, a new User Name must be configured in the SU. The SU will receive services only after configuring it with a User Name that is unique in the Base Station’s database. (see also Section 4.10.7.3.1.1). Summary Information Total Number of SUs: The total number of SUs in the database (including connected and pre-configured SUs) Total Connected SUs SUs Connected to AU Slot N, where N=1-4, 7-9. NOTE An SU that is defined as Temporary will be deleted from the database 20 minutes after being disconnected. 174 Operation SU Menu 4.10.2 Show Summary by AU Select this option to view the total number of SUs connected to a specific AU as well as main details on these SUs, as described in Section 4.10.1. You will be prompted to select the required AU Slot ID. 4.10.3 Upgrading SU’s SW To facilitate efficient upgrade of SU’s SW, three upgrade levels are available: SU level, for upgrading a single SU, described in Section 4.10.7.2.4.2. AU level, for upgrading all SUs served by a specific AU, as described in Section 4.9.5.2.3.3 Base Station level, for upgrading all SUs in the Base Station, as described in the following section. 4.10.4 SW Files in NPU Up to four SU SW files can be stored in the NPU. Any of the available files can be loaded by the NPU to a selected SU. When four SU files are stored in the NPU, a new file cannot be added until at least one of the existing files is deleted. Default SW File Names and Default Actions can be defined. These are the SW File and associated Action that will be used for an SU after network entry. This feature simplifies the upgrade process, by defining the SW File and Action for all SUs served by the Base Station. Two different pairs of Default SW File Name and Default Action may be defined, to optionally support SUs using either Standard Operation Mode or Advanced Si (Advanced - Self Install) Operation Mode. These Default SW File Names and Default Actions are applicable to all SUs in the Base Station using the specified Operation Mode. However, they are not applicable to any SU served by an AU in which the SU SW File (see Section 4.9.5.2.3.3) is other than None (null). They are also not applicable to any Permanent SU whose Configured SW File Name (see Section 4.10.7.2.4.2) is other than None (null). This menu enables viewing the current SU SW files stored in the NPU and deleting selected file(s). It also enables defining the Default SW File Name and Default Action for each Operation Mode. 4.10.4.1 Show Files Select this option to display the SU SW files currently stored in the NPU. For each available SW file, the file name and the version number are displayed. BreezeMAX Modular Base Station System Manual 175 Chapter 4 - Operation and Administration In addition, the Default SU SW File Name (if defined) and Default Action for each Operation Mode are also displayed. 4.10.4.2 Default SW File (Standard) Select this option to define the Name of the SW File to be used for upgrading an SU using Standard Operation Mode after network entry, and the Action to be taken with this file. Not applicable to any SU served by an AU in which the SU SW File (see Section 4.9.5.2.3.3) is other than None (null). They are also not applicable to any Permanent SU whose Configured SW File Name (see Section 4.10.7.2.4.2) is other than None (null). The Default SW File (Standard) option is not applicable for units operating in IP CS Switching Mode. The Default SW File (Standard) parameters are: 4.10.4.2.1 Name The Name of the SW File to be used for upgrading an SU using Standard Operation Mode after network entry. Should be one of the SU SW Files currently stored in the NPU, or None (null). 4.10.4.2.2 Action The operation to be performed with the Default SW File (Standard) after network entry of an SU using Standard Operation Mode: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main. Refer to Section 4.10.7.2.4.2.2 for more details on these Actions. 4.10.4.3 Default SW File (Advanced Si) Select this option to define the Name of the SW File to be used for upgrading an SU using Advanced Si Operation Mode after network entry, and the Action to be taken with this file. Not applicable to any SU served by an AU in which the SU SW File (see Section 4.9.5.2.3.3) is other than None (null). They are also not applicable to any Permanent SU whose Configured SW File Name (see Section 4.10.7.2.4.2) is other than None (null). The Default SW File (Advanced Si) parameters are: 4.10.4.3.1 Name The Name of the SW File to be used for upgrading an SU using Advanced Si Operation Mode after network entry. Should be one of the SU SW Files currently stored in the NPU, or None (null). 4.10.4.3.2 Action The operation to be performed with the Default SW File (Advanced Si) after network entry of an SU using Advanced Si Operation Mode: None (do not load), 176 Operation SU Menu Load (load to Shadow), Run from Shadow or Set as Main. Refer to Section 4.10.7.2.4.2.2 for more details on these Actions. 4.10.4.4 Delete a File Select this option and enter the name of an existing SU SW file to delete it from the NPU Flash memory. 4.10.5 Select by Name Use this option to select an SU by name to access the SU # menu that will enable managing and configuring the selected SU, viewing its performance information or deleting it from the database. 4.10.6 Select by MAC Address Use this option to select an SU by its MAC address to access the SU # menu that will enable managing and configuring the selected SU, viewing its performance information or deleting it from the database. 4.10.7 SU # Menu The SU # menu enables managing and configuring the selected SU. The SU # menu includes the following options: Show Unit Control Configuration Performance Monitoring Show MAC Addresses Behind SU Delete (not applicable for units operating in IP CS Switching Mode) 4.10.7.1 Show Select this option to view the current value/selected option of applicable parameters. In addition, some general status information is displayed, as follows: Equipment and Registration Parameters: MAC Address BreezeMAX Modular Base Station System Manual 177 Chapter 4 - Operation and Administration MAC Address Control Number (a number computed from the MAC Address that can be used for verification purposes) User Name (SU Name) SU Type Operation Mode: Standard for first generation BreezeMAX system, or Advanced Si (Advanced Self Install) for WiMAX-compatible systems supporting Self Install SU. In the current release only Advanced Si mode is applicable. The Operation Mode parameter is not applicable for units operating in IP CS Switching Mode. Organization Name Address Country SU Status (Permanent or Temporary, not applicable for units operating in IP CS Switching Mode) Connected AU Slot ID SUID SU IDU Type (not applicable for units operating in IP CS Switching Mode) Number of Gateways (not applicable for units operating in IP CS Switching Mode) Service Fault Status Configured SW Details Configured SW File Name Configured SW Version Configured Action Uplink/Downlink Parameters Uplink RSSI (dBm) Uplink SNR (dB) Uplink Current Rate Downlink RSSI (dBm) 178 Operation SU Menu Downlink SNR (dB) Downlink Current Rate General HW Parameters Serial Number RF Card HW Revision Boot Version Cumulative Power On Time (hours): The cumulative power-on time of the SU since first power-up. Main Card HW Revision Main Card HW Configuration SW Versions information: Main SW File Name Main SW Version Shadow SW File Name Shadow SW Version Running From (Main or Shadow) MAC (Standard FDD) Parameters (Applicable only to 3.x GHz units. Not applicable for units operating in IP CS Switching Mode) Base Station ID Base Station Mask Phy (Standard FDD) Parameters (Applicable only to 3.x GHz units. Not applicable for units operating in IP CS Switching Mode) Bandwidth (MHz) Uplink (Tx) Frequency (MHz) ATPC Parameters ATPC Support BreezeMAX Modular Base Station System Manual 179 Chapter 4 - Operation and Administration TX Power (dBm) Estimated Distance from BS (meters). The accuracy is from several hundreds of meters for line-of-sight links to 1500 meters for non-line-of-sight links. Bridging Parameters Enable/Disable Limit on Number of Supported Devices Maximum Number of Supported Devices Bridge Aging Time (minutes) Si CPE Parameters Antenna Selection: The antenna configured locally in the Si CPE ¾ Internal (1 - 6) ¾ External ¾ Automatic Interface Type (Ethernet or USB) Smart Card Status (Installed/Not Installed/Fault) Frequency Scanning Parameters Bandwidth (MHz) Start Downlink (Rx) Frequency (MHz) End Downlink (Rx) Frequency (MHz) Scanning Main Step Scanning Intermediate Steps (Configured) Scanning Intermediate Steps (Configured) Discrete Frequencies (if exist) Best BST/AU Parameters Best BST/AU Support Preferred BST/AU ID 180 Operation SU Menu Preferred BST/AU ID Mask Selected BST/AU ID Selected Downlink (Rx) Frequency (MHz) BST/AU ID BST/AU ID Mask Best BST/AU Table (only if Best BST/AU Support is Enabled): includes details of all applicable BST/AUs: BST/AU ID, Downlink (Rx) Frequency, SNR (dB), Rx Antenna. 4.10.7.2 Unit Control The SU Unit Control menu enables defining the SU's status, resetting the SU and managing the SW versions of the unit. The Unit Control menu includes the following options: Status Reset Set Factory Defaults SW Version Control 4.10.7.2.1 SU Status The SU Status parameter enables defining the status of the SU, which determines the services it can receive. The available options are: 1 - Permanent 2 - Temporary NOTE An SU that is defined as Temporary will be deleted from the database when it is disconnected. The SU Status parameter is not applicable for units operating in IP CS Switching Mode (all SUs are Temporary). 4.10.7.2.2 Reset Unit Select this option to reset the unit. To avoid unintentional reset, you will be prompted to confirm the reset request. Changes to some of the configurable BreezeMAX Modular Base Station System Manual 181 Chapter 4 - Operation and Administration parameters are applied only after reset. Refer to Section 4.12 for information on which parameters are changeable in run time and which changes are applied only after reset. 4.10.7.2.3 Set Factory Defaults Select this option to set the SU parameters to their factory default values. Refer to Section 4.12 for information on the factory default values of these parameters. The parameters will revert to their default values after the next reset. 4.10.7.2.4 SW Versions Control (only for Permanent SUs) The SU can contain two SW versions: Main: Each time the SU resets it will reboot using the version defined as Main. Shadow: Normally the Shadow version is the backup version. Each time a new SW File is downloaded to the SU, it will be stored as a Shadow version, replacing the previous Shadow Version. The process of upgrading to a new SW version is controlled by the NPU, and is performed using one of the SU SW files installed in the NPU. If the specified SU SW file does not exist in the SU, it will be downloaded to the SU and the requested operation will be executed, as described below. If it already exists in the SU, then actual loading is not necessary. The following options are available in the SW Version Control menu: Show SW Versions SW File 4.10.7.2.4.1 Show SW Versions Select this option to view the following information: Configured SW (the version to be used upon network entry) Details: Configured SW File Name Configured SW Version Configured Action SW Versions in SU: Main SW File Name 182 Operation SU Menu Main SW Version Shadow SW File Name Shadow SW Version Running From: Main or Shadow Available Versions in NPU: The available SU SW File Names and the SW Version of each file. 4.10.7.2.4.2 SW File Select this option to define the Name of the SW File to be used for upgrading the SU after network, and the Action to be taken with this file: 4.10.7.2.4.2.1Name The Name of the SW File to be used for upgrading the SU after network entry. Should be one of the SU SW Files currently stored in the NPU, or None (null). 4.10.7.2.4.2.2Action The operation to be performed with the SW File after network entry of the SU: None (do not load), Load (load to Shadow), Run from Shadow or Set as Main: None: Select None to cancel a pending request for another operation (an operations will be executed only after the next reset). Download: Select this option to download a specified SW file from the NPU to the Shadow memory of the SU. If the specified file already exists in the SU, no action will take place. Run from Shadow: Select this option to download a specified SW file from the NPU to the Shadow memory of the SU, reset the SU and reboot using the Shadow version. Note that because the process is controlled by the NPU, the SU will continue running from the Shadow version after reset. If the specified file already exists as the Shadow version (meaning that previously a Download operation was executed for this file name), the only actual operation to take place will be to reset and run from Shadow. If the specified file is the current Main version, no action will take place. Set as Main: Select this option to download a specified SW file from the NPU to the Shadow memory of the SU, reset the SU and reboot using the Shadow BreezeMAX Modular Base Station System Manual 183 Chapter 4 - Operation and Administration version, and then swap the Main and Shadow SW Version, so that the running version (which was previously the Shadow version) will become the Main version, to be used after next reset. If the specified file already exists as the running version and it is defined as the Shadow version (meaning that previously a Download and Run from Shadow operation was executed for this file name), the only actual operation to take place will be to swap the Main and Shadow versions. If it is already defined as the Main version, no action will take place. 4.10.7.3 Configuration The SU Configuration menu enables viewing and updating the SU's parameters. The Configuration menu includes the following options: Registration MAC (Standard FDD) (applicable only for 3.x GHz SUs. Not applicable for units operating in IP CS Switching Mode) Phy (Standard FDD) (applicable only for 3.x GHz SUs. Not applicable for units operating in IP CS Switching Mode) Multirate and ATPC Voice/Networking Gateways (not applicable for units operating in IP CS Switching Mode) Ethernet Port Installer Password Bridging Parameters License Best BST/AU (Advanced Si) Radio Parameters (Advanced Si) 184 Operation SU Menu 4.10.7.3.1 Registration Parameters The SU Registration Parameters option in the NPU Monitor enables viewing the SU's Registration parameters. Registration parameters can be configured only locally at the SU (via the Ethernet/USB port). 4.10.7.3.1.1 User Name The User Name can only be configured locally in the SU (SU Name). The default User Name given to a new SU during the definition process (see Section 4.10.8) is SU@ . An SU that is added to the database is added as Permanent. When an SU that exists in the database as a Permanent SU is registered, it receives services based on its MAC address, and the default User Name is replaced by the name configured in the SU. A Base Station cannot serve two SUs with the same User Name. Upon identifying an SU with a User Name that is identical to that of a previously registered SU, the new SU will be registered (to enable management), but will not receive any services. Its name in the NPU database will be changed to SU@ . The system administrator will be informed of the problem through the Fault Status parameter in any of the relevant Show menus (Fault Status 2) and through a trap message (rbSuDuplicateName trap). If the administrator decides that the SU is legitimate and should receive services, a new User Name must be configured in the SU. The SU will receive services only after configuring it with a User Name that is unique in the Base Station’s database. 4.10.7.3.1.2 Organization Name The Organization Name configured in the SU. 4.10.7.3.1.3 Address The Address configured in the SU. 4.10.7.3.1.4 Country The Country name configured in the SU. 4.10.7.3.2 MAC (Standard FDD) Parameters The SU MAC menu enables viewing/updating the MAC parameters for Standard operation mode. These parameters do not affect the operation of the unit when using Advanced Si operation mode. These parameters are provided to support the Automatic Platform Detection mechanism of the dual-mode CPEs, allowing pre-configuration of the relevant parameters before switching the sector to operate in FDD mode using Standard operation mode. These parameters are applicable only to SUs in the 3.x GHz bands. This menu is not applicable to units in the 2.x GHz bands. The MAC (Standard FDD) Parameters are also not applicable for units operating in IP CS Switching Mode. BreezeMAX Modular Base Station System Manual 185 Chapter 4 - Operation and Administration 4.10.7.3.2.1 Base Station ID The Base Station ID is the identifier of the AU to which the SU can connect. An SU can be authenticated by an AU only if the Base Station ID and Base Station ID Mask configured in the SU match the Base Station ID configured for the AU. After power-up the SU will start searching for available AUs in the range defined by the Base Station ID and Base Station ID Mask, and will try to connect to the first found AU whose Base Station ID is in the defined range. A change in the Base Station ID and Base Station ID Mask will take effect only after resetting the SU. The Base Station ID consists of six groups of up to three digits each, where the range for each group is 0 to 255. The first three groups define the Operator ID, the next two groups define the Cell ID and the sixth group defines the Sector (AU) ID. A change in the Base Station ID is applied only after reset. 4.10.7.3.2.2 Base Station ID Mask The Base Station ID Mask, together with the Base station ID define the AU(s) that can synchronize with the SU. The Base Station ID Mask consists of 6 groups of up to 3 digits each, where the range of each group is 0 to 255. The first 3 groups form the mask for the Operator ID. The next 2 groups form the mask for the Cell ID, and the last group forms the mask for the Sector ID. A change in the Base Station ID Mask is applied only after reset. 4.10.7.3.3 Phy (Standard FDD) Parameters The SU Phy menu enables viewing/updating the Phy parameters for Standard operation mode. These parameters do not affect the operation of the unit when using Advanced Si operation mode. These parameters are provided to support the Automatic Platform Detection mechanism of the dual-mode CPEs, allowing pre-configuration of the relevant parameters before switching the sector to operate in FDD mode using Standard operation mode. These parameters are applicable only to SUs in the 3.x GHz bands. This menu is not applicable to units in the 2.x GHz bands. The MAC (Standard FDD) Parameters are also not applicable for units operating in IP CS Switching Mode. 4.10.7.3.3.1 Bandwidth (MHz) The frequency bandwidth used by the radio. A change in the Bandwidth parameter will take effect only after resetting the SU. The available options are: 1 - 1.75 MHz 186 Operation SU Menu 2 - 3.5 MHz 3 - 5 MHz 4 - 7 MHz 5 - 10 MHz A trial to configure a bandwidth that is not supported by the SU will be rejected. 4.10.7.3.3.2 Uplink (Tx) Frequency (MHz) The Uplink (Tx) Frequency is the frequency used in the uplink (from SU to AU). A change in the Uplink Frequency parameter will take effect only after resetting the SU. The available values depend on the HW of the SU and the configured Bandwidth for Standard operation mode. 4.10.7.3.4 Multirate and ATPC Parameters The Multirate and ATPC mechanism are controlled by the AU (except to the option to temporarily control them locally at the SU for testing purposes). The Show Multirate and ATPC Status and Parameters option enables viewing the current status of the applicable parameters. The Set Rates option can be used to set uplink and downlink rates per SU only when Multirate is disabled. 4.10.7.3.4.1 Show The Show option enables viewing the current status of the following parameters: Uplink RSSI (dBm) Uplink SNR (dB) Uplink Current Rate Downlink RSSI (dBm) Downlink SNR (dB) Downlink Current Rate ATPC Support Tx Power (dBm) BreezeMAX Modular Base Station System Manual 187 Chapter 4 - Operation and Administration 4.10.7.3.4.2 Set Rates The Set Rates option is available only when the Multirate algorithm is disabled in the AU (see Section 4.9.5.3.4), allowing to set the Uplink Current Rate and the Downlink Current Rate to any of the available values. The defaults are the last rates used by the Multirate algorithm before it was disabled. For SUs that join the cell when the Multirate algorithm is disabled, the defaults are the applicable Basic Rates. For the available Rate values, see Table 4-6. 4.10.7.3.5 Voice/Networking Gateways The Voice/Networking Gateways option enables viewing details on the Voice/Networking Gateways connected to the SU. This is applicable only for Alvarion's Gateways supporting the DRAP protocol. For each Gateway, the following details are provided: Gateway Type IP Address VLAN ID Number Of Active Calls (applicable only for Voice Gateways) The following gateways are currently available from Alvarion: IDU-NG-4D1W: A Networking Gateway that serves also as an SU IDU, supporting 4 data ports and 1 Wireless LAN port. VG-1D1V: A stand-alone (external) Voice Gateway, supporting 1 data port and 1 POTS port. VG-1D2V: A stand-alone (external) Voice Gateway, supporting 1 data port and 2 POTS ports. The Voice/Networking Gateways option is not applicable for units operating in IP CS Switching Mode. 4.10.7.3.6 Ethernet Port The Ethernet Port menu enables configuration of the Ethernet port operation mode (speed and duplex). 188 Operation SU Menu 4.10.7.3.6.1 Show The Show option enables viewing the configured and actual operation modes: Current Ethernet Port Auto Negotiation Current Ethernet Port Speed and Duplex Configured Ethernet Port Auto Negotiation Configured Ethernet Port Speed and Duplex (NA if Configured Ethernet Port Auto Negotiation is set to Enable) Ethernet Port Link Status (Up or Down) 4.10.7.3.6.2 Update Select the Update option to change the Ethernet Port parameters: Ethernet Port Auto Negotiation: Enable or Disable. Ethernet Port Speed and Duplex: Available only if the configured Ethernet Port Auto Negotiation is set to Disable. The available options are 10 Half, 10 Full, 100 Half and 100 Full. 4.10.7.3.7 Installer Password The Installer Password option enables viewing the current Installer Password and configuring a new password. The Installer Password is used for accessing the SU's Monitor (Installer) program locally, using Telnet via the SU's Ethernet port. The Installer Password consists of a string of up to 20 printable characters, case sensitive. 4.10.7.3.8 Bridging Parameters The Bridging Parameters menu enables setting a limit on the maximum number of Ethernet devices behind the SU and configuring the aging time for devices in the SU's bridging table. NOTE The SU’s Bridging parameters are available only in the NPU. They are not available locally in the SU. The Bridging parameters are: BreezeMAX Modular Base Station System Manual 189 Chapter 4 - Operation and Administration 4.10.7.3.8.1 Enable/Disable Limit on Number of Supported Devices If the Enable/Disable Limit on Number of Supported Devices parameter is set to Disable, the maximum number of supported devices is 512. The default is Disable. 4.10.7.3.8.2 Maximum Number of Supported Devices This parameter is applicable only when the Enable/Disable Limit on Number of Supported Devices parameter is set to Enable. The available range is from 1 to 512 devices. The default is 512. 4.10.7.3.8.3 Bridge Aging Time The Bridge Aging Time sets the aging time for all addresses in the SU's Forwarding Data Base. The available values are from 1 to 1440 minutes. The default is 3 minutes. 4.10.7.3.9 License The License menu is applicable only to L (Limited capabilities) model SU. It enables loading a new license to the SU (if a required license is available in the CPE Licenses Bank). In the current release where only a BW license is available, after such a license is loaded to an SU its’ Type will be updated and it will no long be identified as an L model unit: CPE PRO-L will be changed to CPE PRO, CPE PRO2-L will be changed to CPE PRO2. 4.10.7.3.10 Best BST/AU (Advanced Si) An SU that can communicate with more than one AU may become associated with the first AU it "finds", not necessarily the best choice in terms of quality of communication. Changes in Base Station deployment and subscriber density can accumulate to create substantial changes in SU performance. The quest for load sharing together with the desire to create best throughput conditions for the SU created the need for the Best BST/AU feature, to enable an SU to connect to the best AU in its neighborhood. When the Best BST/AU feature is enabled, the SU scans all AUs in a predefined range, in all frequencies (according to the frequencies defined in the Frequency Scanning menu as described in Section 4.10.7.3.11.2) and in all available antennas (according to the local definition in the SU, as indicated by the Antenna Selection parameter in the Show menu of the SU). Each of the AUs with which the SU can communicate (perform initial phase of network entry) is given a quality mark based on the quality of the signal at which it is received by the SU, for each 190 Operation SU Menu of the relevant antennas. At the end of the scanning period, the SU reaches a Best BST/AU decision according to the information gathered. The AU with the highest quality mark is selected as the Best BST/AU, and the SU will immediately try to associate with it using the relevant frequency and antenna. The range used for scanning is defined by the BST/AU ID and BST/AU ID Mask parameters of the SU. The initial range can be limited by defining a preferred range of BST/AU IDs, and selecting the best AU in the preferred range. If no AU is found in the preferred range, the SU will scan the entire range. The Best BST/AU Parameters menu includes the following options: 4.10.7.3.10.1Show The Show option enables viewing the following: Best BST/AU Support Preferred BST/AU ID Preferred BST/AU ID Mask Selected BST/AU ID Selected Downlink (Rx) Frequency Preferred BST/AU ID Preferred BST/AU ID Mask Best BST/AU Table, displaying for each AU with which the SU can communicate (including the selected AU) the following parameters: BST/AU ID Downlink (Rx) Frequency (MHz) SNR (dB) Rx Antenna 4.10.7.3.10.2Update The Update option enables configuration of the following parameters (changes in Best BST/AU parameters take effect only after reset): BreezeMAX Modular Base Station System Manual 191 Chapter 4 - Operation and Administration 4.10.7.3.10.2.1Best BST/AU Support The Best BST/AU Support parameter allows enabling of disabling the Best BST/AU feature in the SU .If the Best BST/AU Support feature is disabled, the SU will start scanning in the range defined by the BST/AU ID and BST/AU ID Mask and select the first found AU. 4.10.7.3.10.2.2Preferred BST/AU ID and Preferred BST/AU ID Mask These two parameters define the initial range for scanning in order to find the best AU. The SU will select the best AU within this range. If no AU is found within this range, the SU will continue searching in the entire range defined by the BST/AU ID and BST/AU ID Mask parameters. The Preferred BST/AU ID and Preferred BST/AU ID Mask consist of 6 groups of up to 3 digits each, where the range of each group is 0 to 255. The first 3 groups form the base address/mask for the Operator ID. The next 2 groups form the base address/mask for the Cell ID, and the last group forms the base address/mask for the Sector ID. The range defined by these two parameters must be within the range defined by the BST AU ID and BST AU ID Mask. 4.10.7.3.10.2.3 BST/AU ID and BST/AU ID Mask These two parameters define the overall range for scanning in order to find the best AU. The SU will initially scan the range defined by the Preferred BST/AU ID and Preferred BST/AU ID Mask (if applicable). If no AU is found within this range, the SU will continue searching in the entire range defined by the BST/AU ID and BST/AU ID Mask parameters. The BST/AU ID and BST/AU ID Mask consist of 6 groups of up to 3 digits each, where the range of each group is 0 to 255. The first 3 groups form the base address/mask for the Operator ID. The next 2 groups form the base address/mask for the Cell ID, and the last group forms the base address/mask for the Sector ID. 4.10.7.3.10.3Clear Select this option to clear the current Best AU Table. Typically this should be done prior to initiating a full scanning process (otherwise the SU will try first the AUs that are included in the current table). 4.10.7.3.11 Radio Parameters (Advanced Si) The Radio Parameters menu enables viewing and updated the bandwidth, frequency scanning and antenna parameters. The Radio Parameters menu includes the following options: Bandwidth 192 Operation SU Menu Frequency Scanning Discrete Frequencies Update Scanning Table Force Full scanning 4.10.7.3.11.1Bandwidth (MHz) The frequency bandwidth used by the radio. A change in the Bandwidth parameter will take effect only after resetting the SU. The available options are: 1 - 1.75 MHz 2 - 3.5 MHz 3 - 5 MHz 4 - 7 MHz 5 - 10 MHz A trial to configure a bandwidth that is not supported by the SU will be rejected. 4.10.7.3.11.2Frequency Scanning The list of frequencies that participate in the scanning process includes a set of frequencies belonging to the scanning range and/or a set of up to 10 discrete frequencies. The frequencies belonging to the scanning range are defined by Start Downlink (Rx) Frequency, End Downlink (Rx) Frequency, Main Step and Intermediate Steps. The set of frequencies to be scanned is defined as follows: The “Main Frequencies” are defined by the Start Frequency, End Frequency and Main Step, using the formula F(N) =Start Frequency + N*Main Step, with End Frequency as the upper limit: F(1) = Start Frequency + Main Step, F2 = Start Frequency + 2*Main Step.... . The Intermediate Steps can be used to define additional frequencies using a finer resolution. The Intermediate Steps includes a list of up to 8 entries represented by numbers from 1 to 8, or 0 (none) for no Intermediate Steps. The intermediate steps are defined as follows: BreezeMAX Modular Base Station System Manual 193 Chapter 4 - Operation and Administration Table 4-7: Scanning Intermediate Steps Number included Effect on scanned frequencies set None (0) Only “Main Frequencies” (Start Frequency + N*Main Step) as defined above are included in the set Start Frequency is iadded to the set of “Main Frequencies” All intermediate frequencies defined by “Main Frequency” + 125 KHz are added to the scanning set All intermediate frequencies defined by “Main Frequency” + 250 KHz are added to the scanning set All intermediate frequencies defined by “Main Frequency” + 375 KHz are added to the scanning set All intermediate frequencies defined by “Main Frequency” + 500 KHz are added to the scanning set All intermediate frequencies defined by “Main Frequency” + 625 KHz are added to the scanning set All intermediate frequencies defined by “Main Frequency” + 750 KHz are added to the scanning set For a bandwidth of 3.5 MHz: All intermediate frequencies defined by “Main Frequency” + 875 KHz are added to the scanning set For a bandwidth of 5 MHz: All intermediate frequencies defined by “Main Frequency” + 1250 KHz are added to the scanning set For example, the Intermediate Steps list 1,2,5 means that the scanned frequencies are: Start Frequency, Start Frequency + 125 KHz, Start Frequency + 500 KHz, Start Frequency +N*Main Step, Start Frequency +N*Main Step + 125 KHz, Start Frequency +N*Main Step + 500 KHz (N=1, 2,.... End Frequency is the upper limit for the scanned frequencies). The Frequency Scanning menu enables viewing and updating the scanning range parameters. It also enables viewing the current set of discrete frequencies (if exist) as defined in the SU. In the current release discrete frequencies can be defined/modified only locally at the SU. The Frequency Scanning menu includes the following options: 4.10.7.3.11.2.1Show The Show option enables viewing the following: Start Downlink (Rx) Frequency (MHz) 194 Operation SU Menu End Downlink (Rx) Frequency (MHz) Scanning Main Step Scanning Intermediate Steps (Configured) Scanning Intermediate Steps (Actual) 4.10.7.3.11.2.2Update The Update menu enables configuration of the following parameters (changes in Frequency Scanning parameters take effect only after reset): Start Downlink (Rx) Frequency (MHz): The lowest frequency in the range of frequencies to be scanned. The available values depend on the frequency range defined by the Frequency Bands belonging to the applicable Frequency Bands Group (see Section 4.8.5), and the configured Bandwidth. End Downlink (Rx) Frequency (MHz): The highest frequency in the range of frequencies to be scanned. The available values depend on the frequency range defined by the Frequency Bands belonging to the applicable Frequency Bands Group (see Section 4.8.5), and the configured Bandwidth. Scanning Main Step (KHz): The Main Scanning Step, used to define the set of “Main Frequencies” as described above. For a Bandwidth of 3.5 MHz, the range is from 125 KHz to 1750 KHz, in steps of 125 KHz. For a Bandwidth of 5 MHz, the range is from 125 KHz to 5000 KHz, in steps of 125 KHz. Scanning Intermediate Steps: The Intermediate Scanning Steps includes up to 8 entries of numbers between 1 to 8, or 0 for none, that define the intermediate frequencies to be scanned, as described above. The highest step (in KHz) defined by the Intermediate Scanning Steps must be smaller than the Scanning Main Step. BreezeMAX Modular Base Station System Manual 195 Chapter 4 - Operation and Administration 4.10.7.3.11.3Discrete Frequencies The Discrete Frequencies menu enables viewing and editing the list of discrete frequencies that will be included in the Frequency Scanning Table. The Discrete Frequencies menu includes the following options: Show: Select this option to view the current list of discrete frequencies (if any) Update List: Enter a list of up to 10 discrete frequencies, separated by commas (no space). This list will replace the current list of discrete frequencies. Add Frequency: Enter one frequency to be added to the current list of discrete frequencies. Delete Frequency: Enter one frequency to be removed from the current list of discrete frequencies. Delete All: Select this option to delete the entire list of discrete frequencies. 4.10.7.3.11.4Update Scanning Table Select this option to update the frequency scanning table in run time (without resetting the unit). 4.10.7.3.11.5Force Full Scanning Select this option to initiate a full scanning process. 4.10.7.4 Performance Monitoring The Performance Monitoring sub-menu provides the following options: Ports Counters Burst Error Rate Counters 4.10.7.4.1 SU Ports Counters The SU Ports Counters menu enables viewing or resetting the Ethernet and Wireless ports counters. The information displayed for each counter is the accumulated number since the last time the counters were reset. The counters are reset each time the SU is reset, or upon activating the Reset Counters option. The displayed counters include: Ethernet Port Counters 196 Operation SU Menu Data Bytes Received: The total number of data bytes received from the Ethernet link. Management frames and frames with errors are not included. Data Bytes Discarded on Rx: The number of bytes discarded when a packet received from the Ethernet port is not forwarded to the Wireless port due to bridging or classification considerations. Data Bytes Transmitted: The total number of data bytes transmitted to the Ethernet link. Management frames and frames with errors are not included. Data Bytes Discarded on Tx: The number of bytes discarded when a packet received from the Wireless port is not forwarded to the Ethernet port due to bridging or VLAN considerations. Wireless Port Counters Data Bytes Received: The total number of data bytes received from the Wireless link. Management frames and frames with errors are not included. Data Bytes Discarded on Rx: The number of bytes in packets received from the Wireless link and discarded due to MAC protocol receive errors, such as duplicate sequence number, wrong sequence number etc. (not CRC errors). Data Bytes Transmitted: The total number of data bytes transmitted to the Wireless link. MAC Management frames and frames with errors are not included. Data Bytes Discarded on Tx: The number of bytes in packets discarded 4.10.7.4.2 Burst Error Rate Counters In the downlink, each burst uses a single rate and may include data intended for several SUs. In the uplink, each burst is from a different SU (also using a single rate). The Burst Error rate Counters option enables viewing or resetting the Burst Error Rate counters. The information displayed for each rate in uplink and downlink is the accumulated number since the last time the counters were reset. For each direction (uplink/downlink) the displayed information includes the following statistics for each rate: Total Burst BreezeMAX Modular Base Station System Manual 197 Chapter 4 - Operation and Administration Error Bursts Error Rate The counters are reset each time the SU is reset, or upon activating the Reset option. 4.10.7.5 Show MAC Addresses Behind SU Select this option to view a list of the MAC Addresses of the devices behind the SU. If VLAN behind the SU is used, the VLAN ID used by each device is displayed next to its MAC Address. 4.10.7.6 Delete This option enables deleting the selected SU from the database. Only disconnected (Out of Service) SUs can be deleted. The Delete option is not applicable for units operating in IP CS Switching Mode. 4.10.8 Add New SU Select the Add New SU option to add a new SU to the database. The Add New SU sub-menu includes the following parameters: SU MAC Address SW File Name: The SW File to be used by the SU. Should be either a File Name known to exist in the SU or an SU SW File Name in the NPU. Operation: The action to be performed with the specified SW File after the SU connects to the AU (None, Download, Run from Shadow or Set as Main). A new SU that attempts to communicate with the base station when the base station operates in Advanced Mode will be registered only if its MAC address exists in the database. The Add option is not applicable for units operating in IP CS Switching Mode. 4.10.9 Clear All Configured SU SW Files Select this option to clear (delete) the Configured SW File in all Permanent SUs served by the Base Station. 198 Operation Services Menu 4.11 Services Menu 4.11.1 Introduction to Services NOTE This section is not applicable for units operating in IP CS Switching Mode. 4.11.1.1 Services, Subscribers and Service Profiles A Service is a virtual connection between a Subscriber's application and the Network Resource. The Network Resource could be Internet, Content Provider, Corporate Network, etc. The Services are implemented as IEEE 802.16 connections within the wireless domain. Each Service can include up to 4 uplink and 4 downlink connections. Implementation within the provider's backbone domain depends on the specific backbone network. A Subscriber is an entity that may be associated with any number of devices connected to any number of SUs. Each Service associates a certain Service Profile with Subscriber's device(s) behind a specific SU. NOTE The Subscriber entity is not applicable when Services are provisioned using a RADIUS server. The Service Profile's properties depend on the Service Type. All data Services have the following properties: VLAN ID based Classification: Each Service can be associated with up to 16 VLAN IDs, enabling creation of VLANs within the wireless domain and differentiation of services to different end-users behind the same SU based on VLAN ID classification. Quality of Service (QoS) and Priority based Classification: Up to 4 uplink and 4 downlink QoS profiles can be assigned to each Service. The data will be mapped onto these connections by either IEEE 802.1p or DSCP priority tags. This will lead to creation of the corresponding number of Uplink and Downlink connections supporting differentiated services to up to 4 applications based on either IEEE 802.1p or DSCP prioritization schemes. In cases where BreezeMAX Modular Base Station System Manual 199 Chapter 4 - Operation and Administration prioritization is not used, a single pair of uplink/downlink connections is created. Forwarding Rules: A Forwarding Rule is assigned to each Service, defining various features that define the handling of certain message types in the wireless domain. These features, that define the wireless broadcast domain for all Services that use the Forwarding Rule, include Unicast and Broadcast relaying, QoS Profile for Multicasts and Unknown Address Forwarding Policy. The available features depend on the Service Type. Aggregation: Several Services in the Wireless Domain may be aggregated into a single Virtual Private Link (VPL) in the backbone domain. Priority Marking: Ethernet frames transmitted to the backbone may be marked with a configurable priority (DSCP or IEEE 802.1p), enabling the upstream network to handle the traffic accordingly. Auto-configuration: The Ethernet Addresses of the Subscribers' PCs are automatically learnt just as in a standard Bridge. For each Ethernet Address it also learns the VLAN behind the SU it belongs to. Currently, the following Service types are supported: L2 (layer 2) Data Service PPPoE Data Service VoIP Service 4.11.1.2 Service Types 4.11.1.2.1 L2 Service L2 (Layer 2) service transports Layer 2 (Ethernet) frames between the subscriber's site and the Network Resource located behind the provider's backbone and/or between the subscriber's sites. L2 service is transparent to the layer 3 protocol: it can also be used for PPPoE traffic, and it support DRAP-based VoIP services. 4.11.1.2.2 PPPoE Service PPPoE (Point-to-Point Protocol over Ethernet) Access service provides connectivity between a PPPoE enabled devices at the subscriber's site and a PPPoE aware 200 Operation Services Menu Access Concentrator behind the Base Station. In a PPPoE Forwarding Rule, Unicast and Multicast Relaying are always disabled, packets with Unknown Address are always rejected. The frames are forwarded only between the Subscribers' PCs and the PPPoE Access Concentrator. Frames that are not PPPoE Ethertype are discarded. 4.11.1.2.3 VoIP Service The Voice over IP (VoIP) service provides telephony services through an external Voice Gateway connected to the Subscriber Unit's data port. The VoIP service is designed for Alvarion's Voice Gateways, using the proprietary DRAP signaling protocol to identify VoIP sessions and to verify optimal handling of these sessions. Upon provisioning of such a service, the system automatically handles Signaling and RTP connections establishment, including QoS issues. Appropriate connections are established to satisfy to actual demand, according to session status and required bandwidth. In a VoIP Forwarding Rule, Unicast and Multicast Relaying are always enabled, packets with Unknown Address are always forwarded. DRAP (Dynamic Resources Allocation Protocol) is a protocol between the Gateway (installed behind the Subscriber Unit) and the base station. The protocol provides an auto-discovery mechanism for the Gateway, so that no specific configuration is needed and the Gateway can automatically locate and register with the base station. The protocol uses a few simple messages enabling a Voice Gateway to request resources when calls are made, and the base station to dynamically allocate them. Using the DRAP solution has the following advantages: Maintain telephony toll quality over the wireless network - dynamically allocate Continuous Grant (CG) connections for active calls, maintaining the QoS and low jitter needed for toll-quality voice services. Bandwidth is allocated according to actual requirements of each call, taking into account the Codec’s type and sampling rate being used. Allocate CG bandwidth only for the duration of the call - the air resources are allocated and released according to the DRAP messages, which are based on the VoIP signaling. This dynamic allocation ensures efficient use of the air resources. Prevent callers from placing calls if a sector is overloaded - the operator can control and limit the maximum number of concurrent calls per wireless sector and per end user voice gateway. Thus, the operator has complete control of its network and the resources in it. BreezeMAX Modular Base Station System Manual 201 Chapter 4 - Operation and Administration Automatic support of Codec changing in a VoIP call - the DRAP messages update the BreezeMAX equipment on any Codec change or subsequent bandwidth allocation change during the call, hence the exact required bandwidth is always provided. This is essential in fax transmissions where the call might begin with one Codec and switch to another to accommodate the fax transmission. VoIP stack is always in synch with the wireless transport - as the DRAP is integrated into the VoIP stack all calls are terminated according to the VoIP standard. Even if no resources are available, the voice gateway receives an appropriate message from the BreezeMAX system and sends the required signaling message according to the VoIP standard used. 4.11.1.3 Supporting Generic (3rd Party) VoIP Services When using VoIP devices that do not support the DRAP protocol, the required service can be provided through a Data (L2) service with a CG QoS (see Section 4.11.4.7) that is defined in accordance with the estimated bandwidth required for the service. The required bandwidth depends on several parameters, such as codec type, sample rate and T.38 Fax Relay support. The service parameters depend also on the marking features of the VoIP equipment (the ability to use either DSCP or 802.1p to distinguish between RTP, RTCP and VoIP Signaling, and Data traffic). The system includes several pre-configured Service Profiles for commonly used VoIP applications. For details on the pre-configured profiles, refer to Section 4.11.8. For details on defining Service Profiles for generic VoIP devices, refer to Appendix B. 4.11.1.4 Authentication and Service Provisioning The Authentication and Service Provisioning process is affected by the Base Station’s Service Mode (Advanced or Quick) and by specific SU Status (Permanent or Temporary). A Permanent SU (an SU that is defined as such in the database) is provisioned with the “permanent” Service(s) defined for it in the database (if any). The Services are provisioned based on the SU’s MAC Address. A Temporary SU (not defined as Permanent in the database) will be authenticated and provisioned with the Service(s) defined for it by the RADIUS Authentication server. The authentication and service provisioning are based on the SU Name (User Name) and User Password. The SU will be added to the database as a Temporary SU. 202 Operation Services Menu If rejected by the RADIUS Authentication server (or RADIUS Authentication server is not available), then the service provisioning for a temporary SU depends on Service Mode: In Advanced Service Mode, the SU will be rejected (no services). In Quick Service Mode, the SU will be able to use default services based on the Default Service Profile(s), provided it uses the “quick” User Password “quickynikinyoky”. It is possible to define up to two Default Service Profiles: one for PPPoE services and one for L2 or VoIP services (note that L2 service can support also VoIP services). The SU will be added to the database as a Temporary SU. The quickynikinyoky User Password will be sent by the SU in the following cases: A quickynikinyoky is the User Password configured in the SU B A new SU with a null User Name and User Password: The SU will send its MAC Address as User Name with User Password quickynikinyoky. In this case, the SU may receive specific services from the RADIUS Authentication server based on these credentials. C Null (blank) User Password (non-null User Name) RADIUS Authorization and Accounting servers (may be implemented in the same server) are required for proper service provisioning. A Base Station will reject an SU if its name (User Name) is identical to that of another SU that is already served by the Base Station. However, several SUs connected to different Base Stations may be authenticated and provisioned with services by a RADIUS server even if they use the same User Name and User Password. The maximum number of duplicate SUs using the same User Name and User Password that may be authenticated by the Authentication server (Duplicate Sessions) is configured in the RADIUS Accounting server. The service provisioning information sent by the RADIUS Authentication server to the Base Station includes for each service (up to a maximum of 5 services per SU) the name of the Service Profile and VLAN parameters. In addition, the authentication message includes also the Session Timeout and Termination Action. If the Termination Action is Default, the Session (services to the SU) will be terminated. If the Termination Action is RADIUS-request, the Base Station will try to re-authenticate the user. If the service configuration in the Authentication server has been changed, the services provisioned to the SU (if re-authenticated) will be updated accordingly. BreezeMAX Modular Base Station System Manual 203 Chapter 4 - Operation and Administration 4.11.1.5 Using VLANs and VPLs VLANs can be used for creating within the BreezeMAX network virtual groups of multiple end-users (stations) belonging to the same organization (Subscriber). They may also be used to differentiate between different end-users (stations) connected to the same SU. In the backbone, VPL ID (Virtual Private Link ID) is used. VPL is a virtual connection between two points on the network, such as a base station and a service provider or corporate network, identified by the VPL ID, with functionality that is similar to VLAN ID (VLAN on the backbone network). Typically, it is used to separate between different traffic types (e.g. Data and VoIP), or traffic to/from different ISPs or different corporate networks. If the VPL ID is None (No VPL ID) and VLAN Transparency Mode is Off, frames arriving from the infrastructure side with a VLAN ID tag will be discarded. Tagged frames arriving from the wireless domain will be forwarded without a VLAN tag, unless 802.1p Priority Marking is used. If 802.1p Priority Marking is used, tagged frames will be forwarded with VPL ID = 0 and the defined Priority Marking Value. If the VPL ID is other than None (applicable only if VLAN Transparency Mode is Off), all untagged frames forwarded to the network will be tagged with the VPL ID. The VLAN ID in tagged frames arriving from the wireless network will be replaced by the VPL ID. The guidelines that should be followed when defining VPL ID are: Several Service Profiles may share the same VPL ID. However, the following rules must be met: Any number of L2 and/or VoIP Service Profiles may share the same VPL ID, provided they all use the same Forwarding Rule. Any number of PPPoE Service Profiles may share the same VPL ID, provided they all use the same Forwarding Rule. Any number of L2, VoIP and PPPoE Service Profiles may share the same VPL ID, provided that all L2/VoIP Service Profiles use the same Forwarding Rule A, and all PPPoE Service Profiles use the same Forwarding Rule B, where A and B are different. The VLAN Transparency Mode defines the method of transferring packets to the operator's upstream network. When set to On, data packets sent from the Base Station to the backbone will be transferred transparently. The VPL ID parameter is not applicable to Service Profiles with VLAN Transparency Mode On. 204 Operation Services Menu For tagged packets, the VPL ID will be their VLAN tag. For untagged packets, the VPL ID will be None. For packets received from the network, the forwarding decision will be according to the packet's VPL ID. If the VPL ID is unknown (either None or not included in the list of VPL IDs defined for any of the existing, non-transparent Service Profiles), the system will assume this is a transparent VLAN packet (if at least one transparent Service is defined) and transfer it with the original VLAN tag (or untagged if there is no VLAN tag). For transparent services, VLAN Classification Mode can be set to On to enable downlink classification based on both the MAC Address and VLAN ID, to support applications with multiple VLAN IDs per a single MAC address. All Services assigned to the same SU must be configured with the same VLAN Classification Mode (Either On or Off). If VLAN Classification Mode is On, only a single VLAN ID can be defined for the Service. This means that the allowed combinations are: Hybrid VLAN Mode is Off and the VLAN List includes a single VLAN ID. Hybrid VLAN Mode is On and the VLAN List is empty. For transparent services it is also possible to configure an Access VLAN to be used with untagged packets received on the Ethernet port of the SU. This parameter is applicable only for a transparent service with Hybrid Mode set to On, or a transparent service with Hybrid Mode set to Off and an empty VLAN list. A maximum of one Access VLAN can be defined per SU. Hybrid VLAN Mode of operation enables classification of both tagged and untagged packets or untagged packets only, according to the following rules: Table 4-8: Hybrid VLAN Mode Hybrid VLAN Mode VLAN List Forwarded Packets Off Exists Only packets tagged with a VLAN ID that exists in the VLAN List. VLAN List can include up to 16 entries. Empty All (both untagged and tagged with any VLAN ID) Exists Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List. VLAN List can include up to 15 entries. Empty Only untagged frames. On BreezeMAX Modular Base Station System Manual 205 Chapter 4 - Operation and Administration The guidelines that should be followed when defining VLAN IDs and related parameters are: A specific VLAN ID behind a certain SU can be associated only with a single Service of a certain Service Type. It is not possible to define two Services of the same Service Type for the same SU and VLAN ID. However, the same SU and VLAN ID can be associated with two Services of different Service Types, excluding the combination of L2 Service and VoIP Service. For each Service Type, a maximum of one Service that enables forwarding of untagged packets can be assigned to an SU. Forwarding of untagged packets is supported when either Hybrid VLAN Mode is On, or Hybrid VLAN Mode is Off and the VLAN List is empty. It is not possible to define for the same SU two Services of the same Service Type that enable forwarding of untagged packets. However, the same SU and untagged packets can be associated with two Services of different Service Types, excluding the combination of L2 Service and VoIP Service. The maximum total number of VLAN IDs behind the same SU is 16 (15 when there is a Service with Hybrid VLAN Mode On is assigned to the SU). The combination of VLAN Transparency Service On, Hybrid VLAN Mode Off and an empty VLAN List means that all packets are forwarded. This combination should be used only if the Service Provider can ensure that there will not be conflicts between VLAN IDs used by devices behind the SU and existing VPL IDs. To avoid conflicts, a transparent Service Profile cannot be assigned to a Service if the Service's VLAN ID list includes a VLAN ID that is equal to any of the already assigned VPL IDs. The combination VLAN Transparency Mode On, Hybrid VLAN Mode On and an empty VLAN List means that only untagged frames should be forwarded. Such a Service cannot be assigned if there is an assigned non-transparent Service with VPL ID = None. 206 Operation Services Menu 4.11.2 Introduction to Filtering Features NOTE The Filtering features are not applicable for units operating in IP CS Switching Mode. The Filtering features allow a network operator to control the traffic in the system by forwarding or discarding packets according to a set of rules based on multiple allow/deny criteria. This provides both improved network security and better utilization of the wireless medium. The filtering is done at the base station, controlling the traffic between the network and the wireless link. The filtering features enable: Filtering packets arriving from the network interface (From Network Filtering), using a set of either Layer 2 or Layer 3/Layer 4 Filtering Rules. Filtering packets arriving from the wireless link (From Wireless Filtering), using a set of either Layer 2 or Layer 3/Layer 4 Filtering Rules. Discarding packets to/from specific MAC addresses (MAC Address Deny List). This is applicable to MAC Addresses behind SUs. The following figure describes the filtering functionality. Figure 4-2: Filtering Functionality The filtering definition process includes the following steps: Defining list(s) of Filtering Rules. Each Filtering Rule defines a combination of values for certain packet fields. Filtering Rules can be of 2 types: Layer 2 BreezeMAX Modular Base Station System Manual 207 Chapter 4 - Operation and Administration Filtering Rules (using fields of the Ethernet frame) and Layer 3/Layer 4 Filtering Rules (using fields of the IP and/or UDP/TCP headers). Associating each Interface (From Network, From Wireless Link) with a set of either Layer 2 or Layer 3/Layer 4 filters from the relevant Filtering Rules lists, and defining the action to be taken upon receiving a packet that matches any of the selected Filtering Rules: Allow (forward) or Deny (discard). 4.11.3 Common Operations in Services Menu Except for the General submenu, all submenus available in the Services menu enable viewing, editing, deleting and adding applicable entities, such as Subscribers, Services, Service Profiles, etc. Some or all of the following options are available in all submenus of the Services menu: 4.11.3.1 Show All Select this option to see the current details of all entities in the applicable submenu (Subscribers, Services, etc.). 4.11.3.2 Show by This option enables selecting an entity by a specific identifier such as Name or MAC Address. Select this option and enter the appropriate parameter's value to access the menu for a selected entity. This will enable you to choose from the following options: Show: Select this option to view the details of the selected entity. Update: Select this option to edit the details of the selected entity. Delete: Select this option to remove the selected entity from the database. 4.11.3.3 Show List Select this option to view all defined entities in the applicable submenu sorted by the entity type ID (Subscriber ID, Service ID, etc.). The entity ID is an identifier attached automatically to each new entity. You can select a specific entity by its ID. This will open the Selected Entity menu with the Show, Update and Delete options described above. 208 Operation Services Menu 4.11.3.4 Select Select this option to select an entity by its Name. This will open the Selected Entity menu with the Show, Update and Delete options described above. 4.11.3.5 Add Select this option to add a new entity to the database. 4.11.4 The Services Menu The Services menu includes the following options: General (not applicable for units operating in IP CS Switching Mode) Subscribers (not applicable for units operating in IP CS Switching Mode) Services Service Profile Forwarding Rules Priority Classifiers QoS Profiles Filtering Rules (not applicable for units operating in IP CS Switching Mode) Interface Filtering (not applicable for units operating in IP CS Switching Mode) MAC Addresses Deny List (not applicable for units operating in IP CS Switching Mode) 4.11.4.1 General The General menu includes general service parameters. The General menu is not applicable for units operating in IP CS Switching Mode, where the Service Mode is Always Advanced. The General menu includes the following options: 4.11.4.1.1 Show Select this option to view the current values/options of the General parameters. BreezeMAX Modular Base Station System Manual 209 Chapter 4 - Operation and Administration 4.11.4.1.2 Update Select this option to update any of the General parameters. The General parameters are: 4.11.4.1.2.1 Service Mode The Service Mode of the Base Station. The available options are: 1 - Advanced 2 - Quick The default Service Mode is Quick (2). For more information on Service Modes refer to Section 4.11.1.4. 4.11.4.1.2.2 Default L2/VoIP Service Profile The default L2 or VoIP Service Profile to be used by temporary SUs in Quick Mode. Available profiles - any of the L2 or VoIP Service Profiles existing in the database. 4.11.4.1.2.3 Default PPPoE Service Profile The default PPPoE Service Profile to be used by temporary SUs in Quick Mode. Available profiles - any of the PPPoE Service Profiles existing in the database. 4.11.4.2 Subscribers The Subscribers menu enables defining new Subscribers, viewing or editing details of previously defined Subscribers and removing Subscribers from the database. The Subscriber entity is applicable only to Permanent Services (services that are defined in the NPU’s database and are provisioned to Permanent SUs). The Subscribers database in the NPU can hold up to 1024 Subscribers. The Subscriber menu is not applicable for units operating in IP CS Switching Mode The configurable Subscriber's parameters are: 4.11.4.2.1 Subscriber Name This is the name of the subscriber, which must be unique for the entire network. A Subscriber Name consists of up to 32 printable characters. 4.11.4.2.2 First Name An optional parameter for information purposes. 210 Operation Services Menu A First Name consists of up to 50 printable characters. 4.11.4.2.3 Last Name An optional parameter for information purposes. A Last Name consists of up to 50 printable characters. 4.11.4.2.4 Description An optional parameter for information purposes. A Description consists of up to 50 printable characters. 4.11.4.2.5 Admin Status The administrative status of the Subscriber can be either Enabled or Disabled. Select Disabled to disable all services to the Subscriber. 4.11.4.3 Services There are two types of Services: A Permanent Service is defined locally in the database of the Base Station and it defines a Service to be provisioned to a Permanent SU. A Temporary Service can only be granted to a Temporary SU. Typically, Temporary Services are provided by a RADIUS Authentication Server. A Temporary Service may also be granted by the Base Station (based on the Default Service Profiles) when a RADIUS server is not available, or when the SU is rejected by the RADIUS server, provided the unit operates in Quick Service Mode and the SU uses the “quick” User Password “quickynikinyoky”. A Temporary Service is given a default name of # . A Temporary Service cannot be defined, deleted or edited locally using either the Monitor program or SNMP. The Services menu enables viewing all Services, defining new permanent Services, editing details of previously defined permanent Services and removing permanent Services from the database. NOTE The proper process of removing a Service is: 1. Disable the Service (set the Admin Status to Disable) 2. Delete the Service. If the Service is not disabled prior to being the deleted, VLAN ID included in the VLAN List of the deleted Service may still be used by other Services to the same SU that use the same Forwarding Rule as the deleted Service. BreezeMAX Modular Base Station System Manual 211 Chapter 4 - Operation and Administration The Services database in the NPU (Base Station) can hold up to 4095 Services. NOTE Note the following changes that are applicable for units operating in IP CS Switching Mode: Upon switching to IP CS Switching Mode, all previous Services are deleted from the database. Services can only be accepted from AAA server, and are read-only (the Update option is not applicable). A Service includes the following configurable parameters: Service Name, Service Profile Name, SU MAC Address, Service VPL ID (new parameter that defines the VLAN ID to be used in the network side of the NPU) and Admin Status. The following parameters are not applicable for IP Switching Mode Services: Subscriber Name, VLAN List, Hybrid VLAN Mode, VLAN Classification Mode, Access VLAN. The Services menu also enables viewing and resetting the Service counters. 4.11.4.3.1 Service Parameters The Service's parameters are: 4.11.4.3.1.1 Name A Service Name consists of up to 32 printable characters. A “temporary” Service is given a default name of # . 4.11.4.3.1.2 Subscriber Name The Subscriber to which the Service is allocated. The Subscriber Name must be that of a Subscriber that exists in the database. The Subscriber Name is not applicable to a “temporary” Service. 4.11.4.3.1.3 Service Profile Name The Service Profile to be used in the Service. The Service Profile Name must be that of a Service Profile that exists in the database. 4.11.4.3.1.4 SU MAC Address The MAC Address of the SU associated with the Service. The SU MAC Address must be that of a Permanent SU that exists in the database. The MAC Address can be changed (in Update option) only if the Admin status of the Service is set to Disabled. 4.11.4.3.1.5 VLAN List A list of VLAN IDs listing the VLAN IDs behind the SU associated with the applicable Subscriber. 212 Operation Services Menu The list includes VLAN IDs, each one in the range of 0 to 4094, separated by commas. Select null (empty string) for No VLAN. The VLAN List is not displayed in Show menus if the list is empty. When Hybrid VLAN Mode is Off, the VLAN List can include up to 16 VLAN IDs. When Hybrid VLAN Mode is On, the VLAN List can include up to 15 VLAN IDs (the 16th entry is reserved for No VLAN). The maximum total number of VLAN IDs behind a single SU is 16. (15 when there is a Service with Hybrid VLAN Mode On is assigned to the SU). Refer to Section 4.11.1.5 for guidelines regarding VLAN ID configuration. 4.11.4.3.1.6 Hybrid VLAN Mode Hybrid VLAN Mode of operation enables classification of both tagged and untagged packets or untagged packets only, according to the following rules: Table 4-9: Hybrid VLAN Mode Hybrid VLAN Mode VLAN List Forwarded Packets Off Exists Only packets tagged with a VLAN ID that exists in the VLAN List. VLAN List can include up to 16 entries. Empty All (both untagged and tagged with any VLAN ID) Exists Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List. VLAN List can include up to 15 entries. Empty Only untagged frames. On Note that for each Service Type, a maximum of one Service that enables forwarding of untagged packets can be assigned to an SU. Forwarding of untagged packets is supported when either Hybrid VLAN Mode is On, or Hybrid VLAN Mode is Off and the VLAN List is empty. It is not possible to define for the same SU two Services of the same Service Type that enable forwarding of untagged packets. However, the same SU and untagged packets can be associated with two Services of different Service Types, excluding the combination of L2 Service and VoIP Service. 4.11.4.3.1.7 VLAN Classification Mode The VLAN Classification feature enables using VLAN ID (in addition to destination MAC address) for classification of transparent service downlink traffic before transmission to the destination MAC address. The VLAN Classification feature supports applications where multiple VLANs are associated with a single MAC address, allowing to assign different services to different VLANs. BreezeMAX Modular Base Station System Manual 213 Chapter 4 - Operation and Administration VLAN Classification Mode can be set to On only if the following conditions are met: The VLAN Transparency Mode of the applicable Service Profile is set to On. A single VLAN ID is defined for the Service. This means that the allowed combinations are: Hybrid VLAN Mode is Off and the VLAN List includes a single VLAN ID. Hybrid VLAN Mode is On and the VLAN List is empty. All Services assigned to the same SU must be configured with the same VLAN Classification Mode (Either On or Off). 4.11.4.3.1.8 Access VLAN The Access VLAN parameter enables defining a VLAN ID to be used with untagged packets received on the Ethernet port of the SU. This parameter is applicable only for a transparent service (VLAN Transparency Mode is On) with Hybrid Mode set to On, or a transparent service with Hybrid Mode set to Off and an empty VLAN list. A tag with the defined Access VLAN will be added by the NPU to untagged packets in the uplink. The tag will be removed by the NPU from packets in the downlink. For a multicast connection, the NPU will send in addition to the VLAN list the single Access VLAN. The SU will be responsible to remove the Access VLAN if it is received on a multicast connection. A maximum of one Access VLAN can be defined per SU. The range is from 1 to 4094 or null for no Access VLAN. 4.11.4.3.1.9 Admin Status The administrative status of the Service can be either Enabled or Disabled. Select Disabled to disable the Service. 4.11.4.3.1.10Operation Status A read-only display of the operational status that is available in the Show menus only. Up means that the Service is currently in use. 4.11.4.3.2 Performance The Performance sub-menu enables viewing and resetting the connections' counters of the Service. For each connection in each direction the following information is displayed: Connection ID and direction 214 Operation Services Menu Connection Type: BE, NRT, RT or CG. QoS Profile Parameters: The values of the relevant QoS Profile's parameters. Bytes Submitted: The number of bytes submitted by upper layers to this connection. Bytes Transmitted: The number of bytes transmitted to the wireless port through this connection, including retransmissions. Bytes Retransmitted: The number of bytes retransmitted to the wireless port through this connection. Bytes Dropped: The number of bytes dropped from this connection due to congestion in the wireless link. (identical to Bytes Discarded). Bytes Discarded: The number of bytes discarded from this connection due to congestion in the wireless link. (identical to Bytes Dropped). Packets Submitted: The number of packets submitted by upper layers to this connection. Packets Transmitted: The number of packets transmitted to the wireless port through this connection, excluding retransmissions. Packets Dropped: The number of packets dropped from this connection due to congestion in the wireless link. (identical to Packets Discarded). Packets Discarded: The number of packets discarded from this connection due to congestion in the wireless link. (identical to Packets Dropped). Average Delay: The average packet delay in milliseconds, measured for this connection over the last 15 seconds. The value is updated every 15 seconds. Delay Variance: The variance (the standard deviation squared) of the packet delay, in milliseconds squared, measured for this connection over the last 15 seconds. The value is updated every 15 seconds. Maximum Delay: The maximum packet delay in milliseconds, measured for this connection over the last 15 seconds. The value is updated every 15 seconds. BreezeMAX Modular Base Station System Manual 215 Chapter 4 - Operation and Administration Data Loss Indicator (%): The percentage of dropped packets, out of the total demand, measured for this connection over the last 15 seconds. The value is updated every 15 seconds. DLI (%) = 100 * (Packets Dropped) / (Packets Submitted) CIR Utilization (%): The CIR utilization measured for an RT or NRT connection over the last 15 seconds. Not applicable for BE and CG connections. k = 100 x (the minimum between bytes transferred and CIR)/CIR is calculated for each 1 second interval. CIR Utilization equals the average of k over the last 15 seconds, and may vary from 0 to 100. The value is updated every 15 seconds. EIR Utilization (%): Excess Information Rate utilization measured for a BE or NRT connection over the last 15 seconds. Not applicable for RT and CG connections. k=100 x (bytes transferred-CIR)/(MIR-CIR) is calculated for each 1 second interval. In BE CIR = 0. The EIR Utilization equals the average of k over the last 15 seconds, and may range from 0 to 100. The value is updated every 15 seconds. Average Throughput (bits/s): The average throughput, in bits/second, measured for this connection over the last 15 seconds. The value is updated every 15 seconds. 4.11.4.4 Service Profiles Each Service Profile defines the properties of the defined service. Each Service Profile is associated with specific Forwarding Rule and Priority Classifier (Priority Classifiers are not applicable to VoIP Service Profiles). The Service Profile menu enables viewing all Service Profiles in the database, defining new Service Profiles, editing details of previously defined Service Profiles and removing Service Profiles from the database. 216 Operation Services Menu The Service Profiles database can hold up to 1024 Service Profiles. NOTE Note the following changes that are applicable for units operating in IP CS Switching Mode: Upon switching to IP CS Switching Mode, all previous Service Profiles are deleted from the database. There are two new Service Types in IP CS Switching Mode: IP CS Data and IP CS VoIP (the previous L2, PPPoE and VoIPService Types used in Ethernet CS Switching Mode are not applicable for IP CS Switching Mode. Each Service Profile includes the following configurable parameters: Service Type (IP CS Data or IP CS VoIP), Service Profile Name, Priority Classifier. IP CS VoIP Service Profiles use the @@IP Mode VoIP@@ Forwarding Rule (available only in relevant Show menus). The following configurable parameters are not applicable for IP Switching Mode Service Profiles: VLAN Transparency Mode, VPL ID, Priority Marking Mode, Priority Marking Value, Forwarding Rule, Maximum Number of Voice Calls.. The Service Profile's parameters are: 4.11.4.4.1 Service Profile Name A Service Profile Name consists of up to 32 printable characters. 4.11.4.4.2 Service Type The Service Type of the Service Profile. The Service Type parameter is configurable only when defining a new Service Profile (Add). It is not changeable. The currently available Service Type options are: 1 - L2 2 - PPPoE 3 - VoIP For more details refer to Section 4.11.1.2. 4.11.4.4.3 VLAN Transparency Mode The VLAN Transparency Mode defines the method of transferring packets to the operator's upstream network. When set to On, data packets sent from the Base Station to the backbone will be transferred transparently. The VPL ID parameter is not applicable to Service Profiles with VLAN Transparency Mode On. Also the Forwarding Rule selection parameter is not applicable to transparent Service Profiles. All transparent Service Profiles share a single pre-configured Forwarding Rule, and a pre-configured QoS Profile for multicasts. For details on these profiles refer to Table 4-21 and Table 4-22. The pre-configured Transparent Forwarding Rule can be modified but not deleted. BreezeMAX Modular Base Station System Manual 217 Chapter 4 - Operation and Administration For tagged packets, the VPL ID will be their VLAN tag. For untagged packets, the VPL ID will be None. For packets received from the network, the forwarding decision will be according to the packet's VPL ID. If the VPL ID is unknown (either None or not included in the list of VPL IDs defined for any of the existing, non-transparent Service Profiles), the system will assume this is a transparent VLAN packet (if at least one transparent Service is defined) and transfer it with the original VLAN tag (or untagged if there is no VLAN tag). NOTE The combination of VLAN Transparency Service On, Hybrid VLAN Mode Off and an empty VLAN List means that all packets are forwarded. This combination should be used only if the Service Provider can ensure that there will not be conflicts between VLAN IDs used by devices behind the SU and existing VPL IDs. When set to Off, data packets sent from the Base Station to the backbone will be transferred with a VLAN tag according to the VPL ID. The VLAN ID in tagged frames arriving from the wireless network will be replaced by the VPL ID. For packets received from the network, the forwarding decision will be according to the Forwarding Rule defined in the Service Profile with a matching VPL ID. To avoid conflicts, a transparent Service Profile cannot be assigned to a Service if the Service's VLAN ID list includes a VLAN ID that is equal to any of the already assigned VPL IDs. NOTE The combination VLAN Transparency Mode On, Hybrid VLAN Mode On and an empty VLAN List means that only untagged frames should be forwarded. Such a Service cannot be assigned if there is an assigned non-transparent Service with VPL ID = None. 4.11.4.4.4 VPL ID A Virtual Private Link ID to be used in the backbone behind the Base Station. The VPL ID parameter is applicable only to Service Profiles with VLAN Transparency Mode Off. To avoid conflicts, it is not allowed to define a VPL ID that is identical to any of the VLAN IDs in the already assigned transparent Services (Services using a Service Profile with VLAN Transparency Mode On). Several Service Profiles may share the same VPL ID. However, the following rules must be met: 218 Operation Services Menu Any number of L2 and/or VoIP Service Profiles may share the same VPL ID, provided they all use the same Forwarding Rule. Any number of PPPoE Service Profiles may share the same VPL ID, provided they all use the same Forwarding Rule. Any number of L2, VoIP and PPPoE Service Profiles may share the same VPL ID, provided that all L2/VoIP Service Profiles use the same Forwarding Rule A, and all PPPoE Service Profiles use the same Forwarding Rule B, where A and B are different. Available values are in the range of 0 to 4094 or null (empty string) for No VPL ID. A value of 4095 is displayed for No VPL ID. 4.11.4.4.5 Priority Marking Mode In some cases, the network operator may want to use the BreezeMAX system for marking QoS classes, in order to provide network-wide QoS and enable the upstream network to handle the traffic accordingly. Within the BreezeMAX system, frames can be classified to QoS classes using Priority Classifiers, based on either a DSCP header or 802,1p tag. This applies only in cases where an external networking device marks the applicable fields. BreezeMAX also enables marking data transmitted to the backbone network with either DSCP or 802.1p values, where the marking is done per Service Profile. This marking overrides marking performed by external devices behind the SU. Typically, Priority Marking by the NPU will be used in the following cases: The external networking equipment behind the SU does not use priority marking. The service provider does not trust the priority marking defined by the user's equipment. The service provider uses a priority marking type (DSCP or 802.1p) that differs from the one used by the user's networking equipment. The system supports three marking modes: Transparent Marking Mode (No Priority Marking): In this case, the system should forward the frames to the uplink network without any changes. If 802.1p classification is used at the SU, the frames will be transmitted to the operator's network according to the following rules: BreezeMAX Modular Base Station System Manual 219 Chapter 4 - Operation and Administration If VLAN Transparency Mode is Off, the frames will be forwarded with their original 802.1p value and the configured VPL ID. If no VPL ID is configured (VPL ID = Null), the 802.1p tags will not be forwarded. If VLAN Transparency Mode is On, the frames will be forwarded without any change (with the original 802.1p value and VLAN ID, if exists). For DSCP classification at the SU: If the VPL ID is configured (VLAN Transparency Mode Off), the NPU adds an 802.1Q header with the configured VPL ID and 802.1p=0. If VLAN Transparency Mode is On, The NPU adds a 802.1Q header with the original VLAN ID (if exists). Note that there may be a disparity between the DSCP values and the default 802.1p = 0 value. 802.1p Marking Mode: If VLAN Transparency Mode is Off, all frames are marked with the configured VPL ID and the 802.1p Marking Value. If no VPL ID is configured (VPL ID = None), the 802.1Q header will include a VLAN ID = 0. If VLAN Transparency Mode is On, all frames are marked with the original VLAN ID and the 802.1p Marking Value. NOTE If the Priority Marking Value is set to 0, untagged packets (without VLAN ID) will be forwarded without any change. This is applicable to transparent services and to to non-transparent services with no VPL ID. If 802.1p classification is used at the SU, the original 802.1p tags are replaced by the configured 802.1p Marking Value. If DSCP classification is used at the SU, an 802.1Q header is added, with the configured VPL ID (if VLAN Transparency Mode is Off) or the original VLAN ID (if VLAN Transparency Mode is On), and the 802.1p Marking Value. The original DSCP bits are kept. DSCP Marking Mode: All frames are marked with the configured DSCP Marking Values. If 802.1p classification is used at the SU, the frames will be transmitted to the operator's network according to the following rules: 220 Operation Services Menu If VLAN Transparency Mode is Off, the frames will be forwarded with their original 802.1p value and the configured VPL ID. If no VPL ID is configured (VPL ID = Null), the 802.1p tags will not be forwarded. If VLAN Transparency Mode is On, the frames will be forwarded without any change (with the original 802.1p value and VLAN ID, if exists). If DSCP classification is used at the SU, the original DSCP bits will be replaced by the configured DSCP Marking Value. NOTE PPPoE frames can be marked only with 802.1p. DSCP marking for PPPoE services is not supported. In L2 Services, many protocols may be carried over Ethernet. As BreezeMAX bridges all these protocols, there's no way to know what protocol type is encapsulated in Ethernet beforehand. Consequently, if DSCP Marking is configured for L2, the BreezeMAX system uses DSCP marking only for IP packets (e.g. Ethertype 0x0800). If 802.1p Marking is configured, it is used for all frames. 4.11.4.4.6 Priority Marking Value The Priority Marking Value enables definition of the marking value for data frames transmitted to the backbone, according to the configured Priority Marking Mode: Table 4-10: Priority Marking Values Priority Marking Mode Priority Marking Values Range Transparent Not Applicable 802.1p 0-7 DSCP 0 - 63 4.11.4.4.7 Forwarding Rule The Forwarding Rule to be used by the Service Profile. The Forwarding Rule parameter is not applicable to transparent Service Profiles (VLAN Transparency Mode On), as all transparent Service Profiles share the same pre-defined Forwarding Rule. The Forwarding Rule must be one of the names that exist in the database after being defined using the Forwarding Rule menu. The Service Type defined in the selected Forwarding Rule must match the one defined for the Service Profile. However, L2 Forwarding Rule can be used in a VoIP Service Profile, and vice versa. BreezeMAX Modular Base Station System Manual 221 Chapter 4 - Operation and Administration 4.11.4.4.8 Priority Classifier (L2 and PPPoE Service Type) The Priority Classifier to be used by the Service Profile. Not applicable for VoIP Services. The Priority Classifier must be one of the names that exist in the database, after being defined using the Priority Classifier menu. 4.11.4.4.9 Maximum Number of Voice Calls (L2 and VoIP Service Type) The Maximum Number of Voice Calls parameter sets the upper limit on the number of simultaneous VoIP calls that can be supported by the Service using the Service Profile. This parameter is applicable only for L2 and VoIP Service Profiles and calls made by devices that support DRAP. The available range is from 0 to 50 calls. NOTE To properly support Call Waiting, the Maximum Number of Voice Calls should be configured to a value that is twice the number of actual voice sessions that can be supported simultaneously. 4.11.4.4.10 Service Profile Class A read-only parameter (available only in Show menu). Currently the Class of all Service Profiles is Local. 4.11.4.5 Forwarding Rules The Forwarding Rule defines the features that affect forwarding and relaying of data. Data in L2 and VoIP services may be switched only between the Services that share the same Forwarding Rule. Data in PPPoE service can pass only between the subscriber and an Access Concentrator behind the Base Station. The Forwarding Rule menu enables viewing all Forwarding Rules in the database, defining new Forwarding Rules, editing details of previously defined Forwarding Rules and removing Forwarding Rules from the database. 222 Operation Services Menu The Forwarding Rules database can hold up to 255 Forwarding Rules. NOTE Note the following changes that are applicable for units operating in IP CS Switching Mode: Upon switching to IP CS Switching Mode, all previous Forwarding Rules are deleted from the database. A single Forwarding Rule named @@IP Mode VoIP@@ is provided for IP CS VoIP Service Type. Certain parameters of this Forwarding Rule (except the Name and Service Type) can be updated. This Forwarding Rule cannot be deleted. It is not possible to define additional Forwarding Rules. The default values of the @@IP Mode VoIP@@ Forwarding Rule configurable parameters are: Unicast Relaying: Enabled Broadcast Relaying: Enabled Unknown forwarding Policy: Forward Multicast QoS Profile Name: @@IP Mode VoIP@@ The Forwarding Rule's parameters are: 4.11.4.5.1 Forwarding Rule Name A Forwarding Rule Name consists of up to 32 printable characters. 4.11.4.5.2 Service Type The Service Type for which the Forwarding Rule is defined. The Service Type parameter is configurable only when defining a new Service Profile (Add). It is not changeable. The currently available Service Type options are: 1 - L2 2 - PPPoE 3 - VoIP For more details refer to Section 4.11.1.2. 4.11.4.5.3 Unicast Relaying (L2 Service Type) The Unicast Relaying parameter determines whether the AU performs unicast relaying. When the Unicast Relaying parameter is enabled, unicast packets originating from devices on the wireless link can be transmitted back to the wireless link devices. If disabled, these packets are not sent to the wireless link even if they are intended for devices on the wireless link. Unicast Relaying is applicable only to L2 Forwarding Rules. In all PPPoE Forwarding Rules it is set to Disable. In all VoIP Forwarding Rules it is set to Enable. BreezeMAX Modular Base Station System Manual 223 Chapter 4 - Operation and Administration 4.11.4.5.4 Broadcast Relaying (L2 Service Type) The Broadcast Relaying parameter determines whether the AU performs broadcast relaying. When the Broadcast Relaying parameter is enabled, broadcast packets originating from devices on the wireless link are transmitted by the AU back to the wireless link devices, as well as to the backbone. If disabled, these packets are sent only to the backbone and are not sent back to the wireless link. Broadcast Relaying is applicable only to L2 Forwarding Rules. In all PPPoE Forwarding Rules it is set to Disable. In all VoIP Forwarding Rules it is set to Enable. 4.11.4.5.5 Unknown Forwarding Policy (L2 Services Type) The Unknown Forwarding Policy parameter determines the mode of controlling the flow of information from the backbone to the wireless media. Select from the following options: 1 - Reject: The AU will transmit unicast packets only to those addresses that the AU knows to exist on the wireless link side. 2 - Forward: Enables the transmission of all packets, except unicast packets sent to addresses that the AU recognizes as being on its wired backbone side. Unknown Forwarding Policy is applicable only to L2 Forwarding Rules. In all PPPoE Forwarding Rules it is set to Reject. In all VoIP Forwarding Rules it is set to Forward. 4.11.4.5.6 Multicast QoS Profile The Multicast QoS Profile is the QoS Profile to be used for mulicast and broadcast messages. The QoS Profile must be one of the names that exist in the database after being defined using the QoS Profile menu. 4.11.4.5.7 Forwarding Rule Class A read-only parameter (available only in Show menu). Currently the Class of all Forwarding Rules is Local. 4.11.4.6 Priority Classifiers The Priority Classifier defines the QoS Profiles to be allocated to users/sessions differentiated by DSCP or 802.1p priority classifiers. Priority Classifiers are not applicable to VoIP Service Profiles. Each Priority Classifier can define up to 4 uplink and 4 downlink QoS profiles. 224 Operation Services Menu NOTE DSCP based Priority Classifiers are applicable only to IP or ARP traffic. It is not applicable to PPPoE and other Ethernet type traffic. If a Priority Classifier is not applicable for a certain traffic (e.g. DSCP based profile with PPPoE traffic or 802.1p based profile with traffic that do not use VLAN tags), no prioritization scheme will be in effect and quality of service will be determined by the first QoS Profile in the applicable lists. The Priority Classifier menu enables viewing all Priority Classifiers in the database, defining new Priority Classifiers, editing details of previously defined Priority Classifiers and removing Priority Classifiers from the database. The Priority Classifiers database can hold up to 255 Priority Classifiers. NOTE Note the following changes that are applicable for units operating in IP CS Switching Mode: Upon switching to IP CS Switching Mode, all previous Priority Classifiers are deleted from the database. The Priority Type is not configurable, and it is always DSCP (802.1p prioritization is not available in IP CS Switching Mode) The Priority Classifier's parameters are: 4.11.4.6.1 Priority Classifier Name A Priority Classifier Name consists of up to 32 printable characters. 4.11.4.6.2 Priority Type The prioritization mechanism used by the Priority Classifier. The available options are: 1 - DSCP 2 - 802.1p 4.11.4.6.3 Uplink Upper Priority Limits The Uplink Upper Priority Limits parameter enables to define up to four ranges, where each range may be assigned a different QoS Profile for uplink communication. The list includes up to 4 numbers separated by commas, where each number must be higher than its predecessor and the last number must be the highest available for the applicable priority type (7 for 802.1p, 63 for DSCP). Examples for acceptable lists: DSCP Priority: [10,30,50,63]; [21,42,63]; [20,63]; [63]. 802.1p Priority: [2,4,6,7]; [1,5,7]; [6,7]; [7]. BreezeMAX Modular Base Station System Manual 225 Chapter 4 - Operation and Administration A ranges list of 21,42,63 means that packets with a priority from 0 to 21 will be transmitted using the first QoS Profile defined in the Uplink QoS Profiles list (see below), packets with a priority from 22 to 42 will be transmitted using the second QoS Profile defined in the Uplink QoS Profiles list and packets with a priority higher than 42 (43 63) will be transmitted using the third Uplink QoS Profile. A ranges list that includes a single entry (63 for DSCP and 7 for 802.1p) means that priority based classification is not used. 4.11.4.6.4 Uplink QoS Profiles The Uplink QoS Profiles parameter enables to define up to four QoS Profiles, where each entry is the QoS Profile associated with the applicable entry in the Uplink Upper Priority Limits list. The list includes up to four QoS Profile Names, where each name must be one of the names that exist in the database after being defined using the QoS Profile menu. Each entry in the Uplink QoS Profiles list is associated with the applicable entry in the Uplink Priority Ranges list. 4.11.4.6.5 Downlink Upper Priority Limits The DownLink Upper Priority Limits list functionality is the same as that of the Uplink Upper Priority Limits list, except that the ranges are defined for downlink communication. 4.11.4.6.6 Downlink QoS Profiles The Downlink QoS Profiles list functionality is the same as that of the Uplink QoS Profiles list, except that the QoS Profiles are associated with the entries in the Downlink Upper Priority Limits list. 4.11.4.6.7 Priority Classifier Class A read-only parameter (available only in Show menu). Currently the Class of all Priority Classifiers is Local. 4.11.4.7 QoS Profiles The QoS Profile defines the Quality of Service parameters that are applicable when the QoS Profile is used. Different QoS Profile Types are available to support different service requirements: Real-Time (RT) service is designed to meet the needs of Real Time Variable Bit Rate like services characterized by requirements for guaranteed rate and delay such as streaming video or audio. These services are dynamic in nature, but offer periodic dedicated requests opportunities to meet real-time requirements. Because the Subscriber Unit issues explicit requests, the protocol overhead and latency is increased, but capacity is granted only according to the real 226 Operation Services Menu needs of the connection. QoS Profile parameters include Committed Information Rate (CIR) and Committed Time (CT). Non-Real-Time (NRT) service is very similar to the Real-Time polling service except that connections may utilize random access transmit opportunities for sending bandwidth requests. These Non Real Time Variable Bit Rate services, such as file transfer and Internet access with a minimum guaranteed rate, are characterized by requirement for a guaranteed rate, but can tolerate longer delays and are rather insensitive to jitter. QoS Profile parameters include Committed Information Rate (CIR), Committed Time (CT) and Maximum Information Rate (MIR) that limits the rate so that bandwidth intensive services will not expand to occupy the full bandwidth. Best Effort (BE) service is for services where neither throughput nor delay guarantees are provided. The Subscriber Unit sends requests for bandwidth in either random access slots or dedicated transmission opportunities. The occurrence of dedicated opportunities is subject to network load, and the Subscriber Unit cannot rely on their presence. Service parameters include Maximum Information Rate (MIR). Committed Time (CT) is set to a fixed value (Short) and cannot be configured. Continuous Grant (CG) service is tailored for carrying constant bit rate (CBR) real-time services characterized by fixed size data packets on a periodic basis such as VoIP or E1/T1. The Base Station schedules regularly, in a preemptive manner, grants of the size defined at connection setup, without an explicit request from the Subscriber Unit. This eliminates the overhead and latency of bandwidth requests in order to meet the delay and jitter requirements of the underlying service. Service parameters include Packet Size (unsolicited grant size) and Sampling Rate (grant interval). The priorities of allocating bandwidth to connections are in accordance with the QoS Type of the connections, in the following order: CG RT NRT BE For each of the RT, NRT and BE connection, there is a second level of priorities according to the Committed Time (CT), where connections with CT=Short gets the highest priority and connections with CT=Long gets the lowest priority. BreezeMAX Modular Base Station System Manual 227 Chapter 4 - Operation and Administration The QoS Profile menu enables viewing all QoS Profiles in the database, defining new QoS Profiles, editing details of previously defined QoS Profiles and removing QoS Profiles from the database. The QoS Profiles database can hold up to 255 QoS Profiles. NOTE Note the following changes that are applicable for units operating in IP CS Switching Mode: Upon switching to IP CS Switching Mode, all previous QoS Profiles are deleted from the database. A single QoS Profile named @@IP Mode VoIP@@ is provided for IP CS VoIP Service Type. All parameters of this QoS Profile can be updated, and it can also be deleted from the database. Additional QoS Profiles can be defined. The default values of the @@IP Mode VoIP@@ QoS Profile configurable parameters are: Name: @@IP Mode VoIP@@ QoS Type: BE MIR (Kbps): 128 The available QoS Profile parameters depend on the QoS Type. The QoS Profile's parameters are: 4.11.4.7.1 QoS Profile Name A QoS Profile Name consists of up to 32 printable characters. 4.11.4.7.2 QoS Type The QoS Type that defines the QoS parameters that are applicable to the service. The available options are: 1 - CG (Continuous Grant) 2 - RT (Real Time) 3 - NRT (Non real time) 4 - BE (Best Effort) 4.11.4.7.3 CT (RT and NRT QoS Types) The CT (Committed Time) parameter defines the time window over which the information rate is averaged to ensure compliance with the CIR or MIR parameter. It is used also to prioritize bandwidth allocation to connections, where for each QoS Type, connections with a shorter CT get higher priority. The available options are Short (50 mS), Medium (100 mS), and Long (200 mS). 228 Operation Services Menu 4.11.4.7.4 CIR (RT and NRT QoS Types) CIR is the information transfer rate that the system is committed to transfer under normal conditions. The rate is averaged over a minimum increment of time, which is defined by the CT parameter. The range is from 0 to 12,000 Kbps. 4.11.4.7.5 MIR (NRT and BE QoS Types) MIR is the maximum information rate that the system will allow for the connection. The rate is averaged over a minimum increment of time, which is defined by the CT parameter. The range is from 1 to 12,000 Kbps. MIR cannot be lower than CIR (applicable to NRT QoS type). 4.11.4.7.6 Packet Size (CG QoS Type) The Packet Size parameter defines the amount of data in bytes that is expected for each grant. The range is from 64 to 1550 (bytes). 4.11.4.7.7 Sample Interval (CG QoS Type) The Sample Interval parameter defines the time in milliseconds between two successive grants (inter arrival time). The range is from 5 to 100 (milliseconds). 4.11.4.7.8 QoS Profile Class A read-only parameter (available only in Show menu). Currently the Class of all QoS Profiles is Local. 4.11.4.8 Filtering Rules The Filtering Rules menu enables defining L2 Filtering Rules and L3/L4 Filtering Rules. The Filtering Rules option is not applicable for units operating in IP CS Switching Mode. 4.11.4.8.1 L2 Filtering Rules An L2 (Layer 2) Filtering Rule includes the MAC Address and Ethertype. A range of MAC Addresses can be defined for either the Source or Destination MAC Address field. It is possible to define "Any" for either the MAC Address or Ethertype field (but not for both fields). The L2 Filtering Rules menu enables defining new L2 Filtering Rule, viewing details of previously defined L2 Filtering Rules and removing L2 Filtering Rules BreezeMAX Modular Base Station System Manual 229 Chapter 4 - Operation and Administration from the database. It is not possible to edit the parameters of an existing L2 Filtering Rule. The database can hold up to 255 L2 Filtering Rules. The configurable L2 Filtering Rule parameters are: 4.11.4.8.1.1 Rule Name The name of the L2 Rule. The L2 Rule Name is a string of 1 to 32 printable characters. 4.11.4.8.1.2 MAC Address The base MAC Address that is used together with the MAC Address Mask to define a range of MAC addresses. A string of 6 octets (where each octet is represented by two hexadecimal numbers) separated by dashes ("-"). An empty entry means "Any". An "Any" MAC Address means that the filter is defined only by the Ethertype field. 4.11.4.8.1.3 MAC Address Mask The mask that is used together with the MAC Address to define a range of MAC addresses. A string of 6 octets (where each octet is represented by two hexadecimal numbers) separated by dashes ("-"). In a binary representation the string must comprise a series of contiguous binary '1's starting from the MSB, followed by a series of contiguous binary '0's (if the range includes more than a single address). The MAC Address Mask parameter is not applicable for an "Any" MAC Address. 4.11.4.8.1.4 MAC Address Direction The direction (Source or Destination) of the MAC Address. Indicates whether the range defined by the MAC Address and MAC Address Mask is for the Source MAC Address field or the Destination MAC Address field in the Ethernet frame. The MAC Address Direction parameter is not applicable to "Any" MAC Address. 4.11.4.8.1.5 Ethertype The Ethertype of the Ethernet frame. The Ethertype is defined by 4 hexadecimal digits. An empty entry means "Any" and is applicable only if a MAC Address range is defined (the combination of "Any" for both the MAC Address and Ethertype is not allowed). 4.11.4.8.2 L3/L4 Filtering Rules An L3/L4 (Layer 3/Layer 4) Filtering Rule includes the IP Address and Protocol. A range of IP Addresses can be defined for either the Source or Destination IP Address field. It is possible to define "Any" for either the IP Address or Protocol field (but not for both fields). If the specified Protocol is either TCP (6) or UDP (17), either the Source or Destination Port can be defined. It is also possible to define "Any" Port. The direction is applicable for both IP Address and Port. 230 Operation Services Menu The L3/L4 Filtering Rules menu enables defining new L3/L4 Filtering Rule, viewing details of previously defined L3/L4 Filtering Rules and removing L3/L4 Filtering Rules from the database. It is not possible to edit the parameters of an existing L3/L4 Filtering Rule. The database can hold up to 255 L3/L4 Filtering Rules. The configurable L3/L4 Filtering Rule parameters are: 4.11.4.8.2.1 Rule Name The name of the L3/L4 Rule. The L3/L4 Rule Name is a string of 1 to 32 printable characters. 4.11.4.8.2.2 IP Address The base IP Address that is used together with the IP Address Mask to define a range of IP addresses. A string of 4 decimal numbers (where each number is in the range from 1 to 255) separated by dashes ("-"). An empty entry means "Any". An "Any" IP Address means that the filter is defined only by the Protocol field (and optionally by the Port and Port Direction for UDP or TCP protocols). 4.11.4.8.2.3 IP Address Mask The mask that is used together with the IP Address to define a range of IP addresses. A string of 4 decimal numbers (where each number is in the range from 1 to 255) separated by dashes ("-"). In a binary representation, the string must comprise a series of contiguous binary '1's starting from the MSB, followed by a series of contiguous binary '0's (if the range includes more than a single address). The IP Address Mask parameter is not applicable to an "Any" IP Address. 4.11.4.8.2.4 IP Address Direction The direction (Source or Destination) of the IP Address. Indicates whether the range defined by the IP Address and IP Address Mask is for the Source IP Address field or the Destination IP Address field in the IP frame. The IP Address Direction parameter is not applicable to "Any" IP Address. 4.11.4.8.2.5 Protocol The protocol of the IP packet. The Protocol is defined by a decimal number from 0 to 254. An empty entry means "Any" and is applicable only if an IP Address range is defined (the combination of "Any" for both the IP Address and Protocol is not allowed). 4.11.4.8.2.6 Port The TDP/UCP port number, which is applicable only if the Protocol parameter is configured to a value of either 6 (TCP) or 17 (UDP). The Port is defined by a number in the range from 0 to 65534. An empty entry means "Any" port. BreezeMAX Modular Base Station System Manual 231 Chapter 4 - Operation and Administration 4.11.4.8.2.7 Port Direction The direction (Source or Destination) of the Port. Indicates whether the Port number is for the Source Port field or the Destination Port field in the IP frame. The Port Direction parameter is not applicable to "Any" Port. 4.11.4.9 Interface Filtering The Interface Filtering menu enables viewing and editing the filtering mechanisms to be used on frames received from the network (From Network Filtering) and from the wireless link (From Wireless Filtering). The Interface Filtering menu also enables viewing and resetting the Filtering Rules Counters, which display for each of the applicable rules the number of frames matching the rule, accumulated since the last reset. In addition, there is a Non Matching counter, displaying the number of frames that did not match any of the relevant rules. The counters will be reset also after changing the Active Rule Type or disabling the Admin Status. The Interface Filtering option is not applicable for units operating in IP CS Switching Mode. For each of the interfaces, the configurable parameters are: 4.11.4.9.1 L2 Filtering Rules List The L2 Filtering Rules List submenu enables viewing details on the L2 Filtering Rules assigned to the interface, adding Rules (from the L2 Filtering Rules lists) to the list of Rules assigned to the interface, and deleting one or all Rules from the list. It also enables viewing/resetting the counter for a selected Rule. The counter displays the number of frames matching the Rule, accumulated since the last reset. The counter will be reset also after changing the Active Rule Type or disabling the Admin Status. 4.11.4.9.2 L3/L4 Filtering Rules List The L3/L4 Filtering Rules List submenu enables viewing details on the L3/L4 Filtering Rules assigned to the interface, adding Rules (from the L3/L4 Filtering Rules lists) to the list of Rules assigned to the interface, and deleting one or all Rules from the list. It also enables viewing/resetting the counter for a selected Rule. The counter displays the number of frames matching the Rule, accumulated since the last reset. The counter will be reset also after changing the Active Rule Type or disabling the Admin Status. 4.11.4.9.3 Active Rule Type The Active Rule Type parameter defines which of the Filtering Rules List is used. The available options are Layer 2 and Layer 3/4. 232 Operation Services Menu The default option is Layer 2. 4.11.4.9.4 Admin Status The Admin Status parameter defines whether the filtering mechanism is enabled or disabled. The default option is Disabled. 4.11.4.9.5 Default Action The Default Action parameter defines the action to be taken for a frame matching any of the applicable Filtering Rules: Deny (discard) or Allow (forward). If the Default Action is Allow, all frames matching any of the applicable Filtering Rules will be forwarded, and all other frames will be discarded. If the Default Action is Deny, all frames matching any of the applicable Filtering Rules will be discarded, and all other frames will be forwarded. NOTE L3/L4 Filtering Rules are applicable only to IP packets. If the Default Action is Allow, non-IP packets will be forwarded although they do not match any of the applicable Forwarding Rules. The default option is Deny. The menu also enables viewing and resetting the Non Matching Counter, which displays the total number of frames that did not match any of the applicable Filtering Rules, accumulated since the last reset. The counter will be reset also after changing the Active Rule Type or disabling the Admin Status. NOTE Broadcasts and Management frames received from the network, whose destination is the NPU, are never filtered. ARP messages will be forwarded automatically if the following conditions are met: 1. Active Rule Type is L3/L4. 2. The L3/L4 Filtering Rules List includes at least one L4 Filtering Rule (a defined protocol). 3. The Default Action is Allow. This is applicable for both interfaces. BreezeMAX Modular Base Station System Manual 233 Chapter 4 - Operation and Administration 4.11.4.10 Filtering Examples Example 1: Block All Broadcasts Except ARP and PPPoE To block all broadcasts except ARP and PPPoE, define an L2 Filtering Rule that includes all other broadcasts. Typically this includes broadcasts with IP Ethertype. The parameters of this rule will be: MAC Address: FF-FF-FF-FF-FF-FF MAC Address Mask: FF-FF-FF-FF-FF-FF MAC Address Direction: Destination Ethertype: 800 Assuming the intention is to block this broadcast in both directions, this Filtering Rule should be included in the L2 Filtering Rules List of both the From Network Filtering and the From Wireless Filtering. In addition, for both Interfaces the following configuration should be defined: Active Rule Type: Layer 2 Admin Status: Enabled Default Action: Deny If broadcasts using other Ethertypes except IP, ARP and PPPoE are excepted, similar Layer 2 Filtering Rules should be defined for these Ethertypes (with the broadcast MAC Address), and these rules should be added to the applicable Layer 2 Filtering Rules Lists. Example 2: Block DHCP Server behind SU To prevent the use of a DHCP server behind an SU, define the following L3/L4 Filtering Rule: IP Address: Any (empty) Protocol: 17 (UDP) Port: 67 (the source port of the DHCP server) 234 Operation Services Menu Port Direction: Source This Filtering Rule should be included in the L3/L4 Filtering Rules List of the From Wireless Filtering. In addition, the following configuration should be defined for the From Wireless Filtering Interface: Active Rule Type: Layer 3/4 Admin Status: Enabled Default Action: Deny 4.11.4.11 MAC Addresses Deny List The MAC Addresses Deny List menu enables viewing and editing the MAC Addresses Deny List. This list is used to deny services to MAC Addresses behind SUs. Uplink frames whose source MAC address matches any of the entries in the list and downlink frames whose destination MAC address matches any of the entries in the list will be discarded. The MAC Addresses Deny List menu also enables viewing and resetting the MAC Addresses Deny List Counters, which display for each of the entries in the list the number of frames that were discarded because they match the entry, accumulated since the last reset. The MAC Addresses Deny List option is not applicable for units operating in IP CS Switching Mode. 4.11.5 Defining Service Profiles The process of defining completely new Service Profiles should be done "from bottom up", as each entity in the process is defined using one or more "lower level" entities. To define a new Service Profile "from scratch": Define the QoS profiles that should be available for the required Priority Classifier (Uplink/Downlink QoS Profiles) and for the required Forwarding Rule (Multicast QoS Profile). Define the Priority Classifier that should be available for the required Service Profile. All QoS Profiles required for the Uplink/Downlink QoS profiles list must be defined in advance. BreezeMAX Modular Base Station System Manual 235 Chapter 4 - Operation and Administration Define the Forwarding Rule that should be available for the required Service Profile. The QoS Profile required for the Multicast QoS Profile parameter must be defined in advance. Define the Service Profile. The required Priority Classifier and Forwarding Rule must be defined in advance. Once there are various QoS Profiles, Priority Classifiers and Forwarding Rules in the database, you can skip one or more of the steps 1 to 3. 4.11.6 Defining Local (Permanent) Services To define a new Service "from scratch": Verify that the necessary Service Profile(s) are available in the database. Define the relevant Subscriber. Verify that the applicable SU is defined. Use existing Subscriber Name, SU MAC Address and Service Profile Name to define the required Service. Once there are various Subscribers and SUs in the database, you can skip one or more of the steps 2 to 3. 4.11.7 Defining RADIUS Based Services Verify that the necessary Service Profiles are available in the database of the relevant Base Station(s). The Users List of the server must include the default User Name and Password of the NPU (both are KeepAliveUserNameAndPassword). The format of the each Service in the ID Filter in the RADIUS Authentication server(s) is n:v:h:a:c; The ID Filter may include up to 5 Services, separated by “;”: s1;s2;... n = Service Profile Name v= . v=<> is an empty VLAN list. h=ON or OFF, indicating the configured Hybrid VLAN Mode. a= , indicating the configured Access VLAN Mode, and the Access VLAN ID for Access VLAN ON. c=ON/OFF, indicating the configured VLAN Classification Mode. 236 Operation Services Menu Example 1: n=be_96:v=<2,4,5>:h=ON:a= :c=ON; Example 2: n=be_128:v=<22>:h=OFF:a= :c=OFF; 4.11.8 Pre-configured Profiles At manufacturing stage, each NPU is configured with a set of pre configured Profiles. Certain parameters of these Profiles may be modified to reflect specific implementation requirements. When the software version is upgraded, these pre-configured Profiles will not be installed again in the NPU. This is to prevent configuration problems from occurring if the modified Profiles differ from the factory loaded Profiles. Note that upon resetting to NPU to its default configuration (Set Factory Defaults), pre-configured Profiles that were modified are not affected. The pre-configured profiles are not available in IP CS Switching Mode. The pre-configured Service Profiles are: Internet Access L2 - for basic Internet Access service with Best Effort QoS, utilizing L2 Service Type. This is the recommended Default Service Profile for Quick Mode. Internet Access PPPoE - for basic Internet Access service with Best Effort QoS, utilizing PPPoE Service Type. Gold, Silver and Bronze Teleworking - for teleworking applications with different QoS requirements. The pre-configured Teleworking Services are asymmetric: DL Rate > UL Rate. Gold, Silver and Bronze LAN-to-LAN - for LAN-to LAN applications with different QoS requirements. The pre-configured LAN-to-LAN Services are symmetric: DL rate = UL rate. VoIP Service Profiles - for DRAP-based gateways. Two pre configured VoIP service Profiles are defined; VoIP 1V for gateways with a single POTS interface, and VoIP 2V for fully supporting gateways for 2 POTS interfaces. Service Profiles for Generic (non-DRAP) VoIP Devices: 1 POTS Basic VoIP G.729: 1 POTS, no Fax, G.729 codec with a 20 milliseconds sample interval, no priority marking. BreezeMAX Modular Base Station System Manual 237 Chapter 4 - Operation and Administration 1 POTS Advanced VoIP G.729: 1 POTS, T.38 Fax, G.729 codec with a 20 milliseconds sample interval, DSCP priority marking. 1 POTS Basic VoIP G.711: 1 POTS, no Fax, G.711 codec with a 20 milliseconds sample interval, no priority marking. 1 POTS Advanced VoIP G.711: 1 POTS, T.38 Fax, G.729 codec with a 20 milliseconds sample interval, DSCP priority marking. For more details on defining Service Profiles for Generic (3rd party) VoIP devices, refer to Appendix B. Except for the Basic PPPoE Internet Access pre-configured Service Profiles, all pre-configured Data Service Profiles use L2 Service Type to ensure transport of all L2 and L3 protocols. It is recommended to use the L2 Best Effort Internet Access pre configured Service Profile as the Default Data Service Profile in Quick Mode. The following tables provide details on the pre-configured Service Profiles, Forwarding Rules, Priority Classifiers and QoS Profiles. Table 4-11: Pre-Configured Data Service Profiles Name Service Type VPL ID* Forwarding Rule Priority Classifier Internet Access L2 L2 Null Internet Access L2 BE Asymmetric Internet Access PPPoE PPPoE 11 Internet Access PPPoE BE Asymmetric Gold Teleworking L2 12 Gold Teleworking Gold Asymmetric Silver Teleworking L2 13 Silver Teleworking Silver Asymmetric Bronze Teleworking L2 14 Bronze Teleworking Bronze Asymmetric Gold LAN-to-LAN L2 15 Gold LAN-to-LAN Gold Symmetric Silver LAN-to-LAN L2 16 Silver LAN-to-LAN Silver Symmetric Bronze LAN-to-LAN L2 17 Bronze LAN-to-LAN Bronze Symmetric In all pre-configured Data Service Profiles, the Priority Marking Mode is set to Transparent and the Maximum Number of Voice Calls is 0. * VPL IDs are assigned arbitrary values and should be configured in accordance with specific network implementation, taking into account the considerations described in Section 4.11.1.5. As Internet Access L2 is the recommended Default Data Service Profile, a VPL ID = None is used to ensure availability of basic data services in Quick Mode. 238 Operation Services Menu Table 4-12: Pre-Configured Forwarding Rules for Data Service Name Service Type Unicast relaying Broadcast Relaying Unknown forwarding Policy Multicast QoS Internet Access L2 L2 Disable Disable Forward BE 750 Internet Access PPPoE PPPoE Disable (hard coded) Disable (hard coded) Forward (hard coded) BE 750 Gold Teleworking L2 Disable Disable Forward NRT 1500/1750 Silver Teleworking L2 Disable Disable Forward NRT 1000/1150 Bronze Teleworking L2 Disable Disable Forward NRT 750/850 Gold LAN-to-LAN L2 Enable Enable Forward NRT 1500/1750 Silver LAN-to-LAN L2 Enable Enable Forward NRT 1000/1150 Bronze LAN-to-LAN L2 Enable Enable Forward NRT 750/850 Table 4-13: Pre-Configured Priority Classifiers for Data Services Name Type Uplink Priority Ranges Uplink QoS Profiles Downlink Priority Ranges Downlink QoS Profiles BE Asymmetric 802.1p BE 96 BE 750 Gold Asymmetric 802.1p NRT 128/192 NRT 1500/1750 Silver Asymmetric 802.1p NRT 96/128 NRT 1000/1150 Bronze Asymmetric 802.1p NRT 96/128 NRT 750/850 Gold Symmetric 802.1p NRT 1500/1750 NRT 1500/1750 Silver Symmetric 802.1p NRT 1000/1150 NRT 1000/1150 Bronze Symmetric 802.1p NRT 750/850 NRT 750/850 BreezeMAX Modular Base Station System Manual 239 Chapter 4 - Operation and Administration Table 4-14: Pre-Configured QoS Profiles for Data Services Name Type CIR (Kbps) MIR (Kbps) CT BE 96 Best Effort NA 96 Short* BE 750 Best Effort NA 750 Short* NRT 96/128 Non Real Time 96 128 Medium NRT 128/192 Non Real Time 128 192 Medium NRT 750/850 Non Real Time 750 850 Medium NRT 1000/1150 Non Real Time 1000 1150 Medium NRT 1500/1750 Non Real Time 1500 1750 Medium * Although Medium CT may be indicated for these BE QoS Profiles (legacy from previous versions), the actual CT is Short. Table 4-15: Pre-Configured VoIP Service Profiles (for DRAP-based Gateways) Name Service Type VPL ID* Priority Marking Mode Maximum Number of Voice Calls** Forwarding Rule VoIP 1V VoIP 18 Transparent VoIP VoIP 2V VoIP 18 Transparent VoIP * VPL IDs are assigned arbitrary values and should be configured in accordance with specific network implementation, taking into account the considerations described in Section 4.11.1.5. ** To properly support Call Waiting, an additional connection must be available. Thus, the Maximum Number of Voice Calls is twice the maximum expected number of actual voice sessions. Table 4-16: Pre-Configured Service Profiles for Generic (non-DRAP) VoIP Services Name Service Type VPL ID* Forwarding Rule Priority Classifier 1 POTS Basic VoIP G.729 L2 19 VoIP 1 POTS Basic VoIP G.729 1 POTS Advanced VoIP G.729 L2 19 VoIP 1 POTS Advanced VoIP G.729 1 POTS Basic VoIP G.711 L2 19 VoIP 1 POTS Basic VoIP G.711 1 POTS Advanced VoIP G.711 L2 19 VoIP 1 POTS Advanced VoIP G.711 240 Operation Services Menu In all pre-configured Service Profiles for generic VoIP services, the Priority Marking Mode is set to Transparent and the Maximum Number of Voice Calls is 0. * VPL IDs are assigned arbitrary values and should be configured in accordance with specific network implementation, taking into account the considerations described in Section 4.11.1.5. Table 4-17: Pre-Configured Forwarding Rule for VoIP Services Name Service Type Unicast Relaying Broadcast Relaying Unknown forwarding Policy Multicast QoS VoIP VoIP Enable (hard coded) Enable (hard coded) Forward (hard coded) BE 128 All pre-configured Service profiles for VoIP (DRAP-based VoIP Services and Generic (3rd party) VoIP Services share the same pre-configured Forwarding Rule, to enable direct communication between all users of VoIP Services, regardless of the gateway type and other possible differences in the Service Profiles. Table 4-18: Pre-Configured Priority Classifiers for Generic (non-DRAP) VoIP Service Name Type Uplink Priority Ranges Uplink QoS Profiles Downlink Priority Ranges Downlink QoS Profiles 1 POTS Basic VoIP G.729 DSCP 63 CG 47 63 CG 47 1 POTS Advanced VoIP G.729 DSCP BE 64 BE 64 26 RT 6 26 RT 6 63 CG 38 63 CG 38 1 POTS Basic VoIP G.711 DSCP 63 CG 108 63 CG 108 1 POTS Advanced VoIP G.711 DSCP BE 64 BE 64 26 RT 11 26 RT 11 63 CG 88 63 CG 88 BreezeMAX Modular Base Station System Manual 241 Chapter 4 - Operation and Administration Table 4-19: Pre-Configured BE and RT QoS Profile for VoIP Services Name Type CIR (Kbps) MIR (Kbps) CT BE 64 Best Effort NA 64 Short* BE 128 Best Effort NA 128 Short* RT 6 Real Time NA Short RT 11 Real Time 11 NA Short * Although Medium CT may be indicated for these BE QoS Profiles (legacy from previous versions), the actual CT is Short. Table 4-20: Pre-Configured CG QoS Profile for Generic (non-DRAP) VoIP Services Name Type Packet Size (Bytes) Sample Interval (msec) CG 38 Continuous Grant 94 20 CG 47 Continuous Grant 117 20 CG 88 Continuous Grant 218 20 CG 108 Continuous Grant 270 20 The following tables provide details on the pre-configured Profiles used for Transparent Services (VLAN Transparency Mode is ON): Table 4-21: Pre-Configured Forwarding Rule for Transparent Services Name Service Type Unicast Relaying Broadcast Relaying Unknown forwarding Policy Multicast QoS @@Transparent@@ L2 Enable Enable Forward @@Transparent@@ NOTE The name of the Transparent Forwarding Rule cannot be edited. Table 4-22: Pre-Configured QoS Profile for Transparent Services Name Type CIR (Kbps) MIR (Kbps) CT @@Transparent@@ Best Effort NA 128 Short* * Although Long CT may be indicated for this BE QoS Profile (legacy from previous versions), the actual CT is Short. 242 Operation NPU Parameters Summary 4.12 NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Base Station Configuration Parameters Device Name Up to 255 printable characters Null Yes Device Location Up to 255 printable characters Null Yes Switching Mode 1 - Ethernet CS Ethernet CS No Enable Yes 2 - IP CS ATPC Enable/Disable 1 - Disable 2 - Enable Disable is temporary until next reset of the NPU or AUs Optimal Uplink RSSI (dBm) -90 to -60 (-80 to -74 at the AUs) -73 (-74 at the AUs) Yes Operator ID X.X.X 186.190.0 No 0.250 No TDD No 50-50 (%) No Enable No X: 0-255 Cell ID X.X X: 0-255 Duplex Mode FDD, TDD Only TDD spplicable to current version) DL-UL Ratio 1: 65-35 (%) 2: 60-40 (%) 3: 55-45 (%) 4: 50-50 (%) 5: 45-55 (%) 6: 40-60 (%) 7: 35-65 (%) (See Section 4.5.2.6.2 for limitations) External 1PPS Clock 1 - Disable 2 - Enable BreezeMAX Modular Base Station System Manual 243 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated External 16MHz Clock 1 - Disable Disable No 2 - Enable Chain Chain Number 1 - 1500 0 (not defined yet-must be defined) No GPS Protocol 0 - None Timble No 1 - Trimble 2 - Symmetricom Time Zone Offset From UTC -12:00 to +13:00 +02:00 Yes Stop Tx After Hold Over Timeout 1 - Disable Disable Yes Hold Over Passed Timeout 0 - 2880 (minutes) 30 (minutes) Yes 1 - Critical Info Yes 2 - Enable Base Station Alarms and Traps Traps Display Filter-Minimum Severity 2 - Major 3 - Minor 4 - Warning 5 - Info Traps Display Filter-Days 1 - 31 days 31 days Yes Traps Configuration-Admin Status 1 - Disable Enable Yes Trap Configuration-Severity 1 - Critical Depends on trap Yes 0 (no suppression) Yes 2 - Enable 2 - Major 3 - Minor 4 - Warning 5 - Info Trap Configuration-Suppression Interval 0 - 86,400 (seconds). 0 means no suppression RADIUS General Parameters 244 Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Shared Secret Up to 16 printable characters, case sensitive. Available only via Monitor. null (must be defined) Yes Retry Interval (sec) 1-5 (seconds) 5 (seconds) Yes Maximum Number of Retries 0-5 Yes Keep Alive Timeout (sec) 60-180 (seconds) 60 (seconds) Yes RADIUS Authentication (up to two servers) IP Address IP address null Yes UDP Port 1-65535 1812 Yes Server Status 1 - Primary Yes 2 - Secondary (Only one server can be Primary) RADIUS Accounting (up to two servers) IP Address IP address null Yes UDP Port 1-65535 1813 Yes Server Status 1 - Primary Yes 2 - Secondary (Only one server can be Primary) NPU Parameters Administrator Password Up to 16 printable characters, case sensitive admin Yes Installer Password Up to 16 printable characters, case sensitive installer Yes Monitor Password Up to 16 printable characters, case sensitive monitor Yes Monitor Inactivity Timeout 0 - 60 minutes 10 minutes Yes (0 means no timeout) Management Port Parameters Management Port IP Address IP address 10.0.0.1 No Management Port Subnet Mask IP address 255.255.255.0 No Management Port Gateway IP address 0.0.0.0 No Management Port Destination Subnet IP address 0.0.0.0 No BreezeMAX Modular Base Station System Manual 245 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Management Port Destination Subnet Mask IP address 0.0.0.0 No Management Port Management Traffic Enable/Disable 1 - Disable Enable Yes 2 - Enable Data Port Parameters Data Port IP Address IP address 1.1.1.3 No Data Port Subnet Mask IP address 255.255.255.0 No Data Port Gateway IP address 0.0.0.0 No Data Port Management VLAN 0-4094 or Null for No VLAN Null Yes Data Port Speed 1 - 100 Mbps 100 Mbps No Enable Yes 2 - 1 Gbps Data Port Management Traffic Enable/Disable 1 - Disable 2 - Enable Authorized Managers Authorized Manager IP Address IP address NA Yes Authorized Manager Send Traps 1 - Disable NA Yes Authorized Manager Read Community Up to 23 printable characters, case sensitive NA Yes Authorized Manager Write Community Up to 23 printable characters, case sensitive NA Yes 1 - 1440 minutes or 0 for no aging 10 minutes Yes 1 - 100 Yes 2 - Enable Bridge Bridge Aging Time Voice DRAP TTL Retries Radio Cluster Parameters Radio Cluster ID 1-6 Name Up to 32 printable characters Null Yes Location 0 to 255 printable characters Null Yes Sector Heading 0 - 359 (degrees) Yes Sector Beam Width 0 - 359 (degrees) 90 Yes 246 Yes Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated ODU Parameters ODU ID 1 - 24 Yes Associated Radio Cluster 1-6 Yes (must be a defined Radio cluster ID) Configured ODU Frequency Band According to loaded Frequency Bands file 0 (Not Defined) Yes Tx Power (dBm) 13 - 50 (dBm, in increments of 0.25) 28 Yes Disable Yes Actual range depends on ODU Type: 3.5 GHz units: 24 to 34 dBm. 2.x GHz units with HC08 version 134: 25 to 36 dBm. 2.x GHz units with HC08 version 137: 30 to 36 dBm. Admin Status 1 - Disable 2 - Enable AU - SW Files in NPU - Default SW File (Standard) Not applicable for current release. Name A name of an AU SW File that exist in the NPU Yes Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main AU - SW Files in NPU - Default SW File (Advanced Si) Name A name of an AU SW File that exist in the NPU Yes Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main AU - Unit Control - SW Versions Control SW File: Name A name of an AU SW File that exist in the NPU BreezeMAX Modular Base Station System Manual Yes 247 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range SW File: Action 0 - None Default Run-Time Updated Yes 1 - Load 2 - Run from Shadow 3 - Set as Main SU SW File: Name A name of an SU SW File that exist in the NPU Yes SU SW File: Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main AU MAC Parameters Sector ID 0-255 206 No ARQ Enable/Disable 1 - Disable Disable No 20 km No 3.5 No No Diversity Yes (Causes automatic reset) 2 - Enable (should not be used in version 4.0.2) Maximum Cell Radius (km) Bandwidth 3.5 MHz: 10 -50 km Bandwidth 5 MHz: 7 - 45 km AU Phy Parameters Bandwidth (MHz) 1 - 1.75 2 - 3.5 3-5 4-7 5 - 10 Only values supported by the AU will be accepted AU Multi Channel Parameters Diversity Mode 1 - No Diversity 2 - Second Order Diversity 3 - Fourth Order Diversity for NLOS 4 - Fourth Order Diversity for LOS and NLOS 248 Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Channel ID 1-4 Associated ODU 1 - 24 (must be a defined ODU ID) No Downlink (Tx) Frequency (MHz) According to the Configured ODU Frequency Band and AU Bandwidth No Admin Status 1 - Disable Disable No Enable Yes BPSK 1/2 Yes 2 - Enable AU Multirate Parameters Multirate Enable/Disable 1 - Disable 2 - Enable Disable is temporary until next reset Uplink Basic Rate 1 - BPSK 1/2 2 - BPSK 3/4 (not applicable for TDD) 3 - QPSK 1/2 4 - QPSK 3/4 5 - QAM16 1/2 6 - QAM16 3/4 7 - QAM64 2/3 8 - QAM64 3/4 Minimum Number of Sub-Channels 1, 2, 4, 8, 16 No Downlink Basic Rate 1 - BPSK 1/2 BPSK 1/2 Yes 2 - BPSK 3/4 (not applicable for TDD) 3 - QPSK 1/2 4 - QPSK 3/4 5 - QAM16 1/2 6 - QAM16 3/4 7 - QAM64 2/3 8 - QAM64 3/4 AU Voice Parameters BreezeMAX Modular Base Station System Manual 249 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Maximum Number of Voice Calls 0 - 300 50 Yes AU Minimum Allocation 1 - 5 Symbols 5 Symbols No 2 - 3 Symbols Available only via Monitor. SU - SW Files in NPU - Default SW File (Standard) Not applicable for current release. Name A name of an SU SW File that exist in the NPU Yes Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main SU - SW Files in NPU - Default SW File (Advanced Si) Name A name of an SU SW File that exist in the NPU Yes Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main SU - Unit Control Parameters SU Status 1 - Permanent Permanent Yes 2 - Temporary SW File: Name A name of an SU SW File that exist in the NPU Yes SW File: Action 0 - None Yes 1 - Load 2 - Run from Shadow 3 - Set as Main SU Registration Parameters Name Read-only (User Name) NA Organization Name Read-only NA 250 Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Address Read-only NA Country Read-only NA SU MAC (Standard FDD) Parameters Base Station ID X.X.X.X.X.X No X: 0 - 255 Base Station ID Mask X.X.X.X.X.X No X: 0 - 255 SU Phy (Standard FDD) Parameters Bandwidth (MHz) 1 - 1.75 No 2 - 3.5 3-5 4-7 5 - 10 Only values supported by the SU will be accepted Uplink (Tx) Frequency (MHz) Depends on the SU’s HW and the configured Bandwidth. No SU Multirate and ATPC Parameters Uplink Rate Applicable only if Multirate in AU is disabled: New SU: Uplink Basic Rate. 1 - BPSK 1/2 Connected SU: Last used rate. 2 - BPSK 3/4 (not applicable for TDD) Yes 3 - QPSK 1/2 4 - QPSK 3/4 5 - QAM16 1/2 6 - QAM16 3/4 7 - QAM64 2/3 8 - QAM64 3/4 BreezeMAX Modular Base Station System Manual 251 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Downlink Rate Applicable only if Multirate in AU is disabled: New SU: Downlink Basic Rate. Yes 1 - BPSK 1/2 2 - BPSK 3/4 (not applicable for TDD) Connected SU: Last used rate. 3 - QPSK 1/2 4 - QPSK 3/4 5 - QAM16 1/2 6 - QAM16 3/4 7 - QAM64 2/3 8 - QAM64 3/4 SU Ethernet Port Parameters Ethernet Port Auto Negotiation 1 - Disable No 2 - Enable Ethernet Port Speed and Duplex Available only if Ethernet Port Auto Negotiation is set to Disable No 1 - 10 Mbps Half Duplex 2 - 10 Mbps Full duplex 3 - 100 Mbps Half Duplex 4 - 100 Mbps Full Duplex SU Password Password Up to 20 printable characters, case sensitive Yes SU Bridging Parameters Enable/Disable Limit on Number of Supported Devices 1 - Disable Disable Yes Maximum Number of Supported Devices 1 - 512 512 Yes Bridge Aging Time 1 - 1440 minutes 3 minutes Yes 2 - Enable SU Best BST/AU Parameters (Advanced Si) Best BST/AU Support 1 - Disable No 2 - Enable 252 Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Preferred BST/AU ID X.X.X.X.X.X Default Run-Time Updated No X: 0 - 255 Preferred BST/AU ID Mask X.X.X.X.X.X No X: 0 - 255 BST/AU ID X.X.X.X.X.X No X: 0 - 255 BST/AU ID Mask X.X.X.X.X.X No X: 0 - 255 SU Radio Parameters (Advanced Si) Bandwidth (MHz) 1 - 1.75 No 2 - 3.5 3-5 4-7 5 - 10 Only values supported by the SU will be accepted Start Downlink (Rx) Frequency (MHz) Depends on Frequency Bands Group available for the AU, and the Bandwidth. No End Downlink (Rx) Frequency (MHz) Depends on Frequency Bands Group available for the AU, and the Bandwidth. No Scanning Main Step (KHz) Bandwidth 3.5 MHz: 125 to 1750 in steps of 125 No Bandwidth 5 MHz: 125 to 5000 in steps of 125 Scanning Intermediate Steps Up to 8 numbers (1-8) separated by commas, or 0 (none) No Services - General Parameters Service Mode 1 - Advanced Quick Yes 2 - Quick Default L2/VoIP Service Profile Name of an existing L2 or VoIP Service Profile, or None. Internet Access L2 Yes Default PPPoE Service Profile Name of an existing PPPoE Service Profile, or None. None Yes BreezeMAX Modular Base Station System Manual 253 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Services - Subscribers Parameters Subscriber Name Up to 32 printable characters. Must be unique in the network. Yes First Name Up to 50 printable characters. Yes Last Name Up to 50 printable characters. Yes Description Up to 50 printable characters. Yes Admin Status 1 - Disabled Yes 2 - Enabled Services - Services Parameters Service Name Up to 32 printable characters. Yes Subscriber Name A Subscriber Name (up to 32 printable characters) that exists in the database Yes SU MAC Address MAC Address of an SU that exists in the database Yes Service Profile Name A Service Profile Name (up to 32 printable characters) that exists in the database Yes VLAN List A list of different numbers separated by commas where each entry is from 1 to 4094. Null is for No VLAN. Yes Up to 16 entries when Hybrid VLAN Mode is Off. Up to 15 entries when Hybrid VLAN Mode is On. Hybrid VLAN Mode 1 - Off Yes 2 - On VLAN Classification Mode 1 - Off Yes 2 - On Access VLAN 1-4094 Yes Admin Status 1 - Disabled Yes 2 - Enabled Services - Service Profiles Parameters Service Profile Name 254 Up to 32 printable characters. Yes Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Service Type Applicable only for new Service Profiles (Add): Default Run-Time Updated Yes 1 - L2 2 - PPPoE 3 - VoIP VLAN Transparency Mode 1 - Off Yes 2 - On VPL ID 0 - 4094 or null for No VPL ID. Yes Priority Marking Mode 1 - Transparent Yes 2 - 802.1p 3 - DSCP Priority Marking Value 802.1p: 0 - 7 Yes DSCP: 0 - 63 Forwarding Rule A Forwarding Rule Name (up to 32 printable characters) that exists in the database Yes Priority Classifier A Priority Classifier Name (up to 32 printable characters) that exists in the database Yes Maximum Number of Voice Calls 0 - 50 Yes Services - Forwarding Rule Parameters Forwarding Rule Name Up to 32 printable characters Yes Service Type Applicable only for new Service Profiles (Add): Yes 1 - L2 2 - PPPoE Unicast Relaying Applicable only for L2 Service type: Yes 1 - Disabled 2 - Enabled BreezeMAX Modular Base Station System Manual 255 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Broadcast Relaying Applicable only for L2 Service type: Default Run-Time Updated Yes 1 - Disabled 2 - Enabled Unknown Forwarding Policy Applicable only for L2 Service type: Yes 1 - Reject 2 - Forward Multicast QoS Profile A QoS Profile Name (up to 32 printable characters) that exists in the database Yes Services - Priority Classifiers Parameters Priority Classifier Name Up to 32 printable characters Yes Priority Type 1 - DSCP Yes 2 - 802.1p Uplink Priority Ranges Up to 4 numbers separated by commas, where each number must be higher than its predecessor and the last number must be the highest available for the applicable priority type (7 for 802.1p, 63 for DSCP). Yes Uplink QoS Profiles Up to four QoS Profile Names separated by commas, where each name (up to 32 printable characters) is a name of a QoS Profile that exists in the database. The number of entries in the list must be identical to number of entries in Uplink Priority Ranges list. Yes Downlink Priority Ranges Up to 4 numbers separated by commas, where each number must be higher than its predecessor and the last number must be the highest available for the applicable priority type (7 for 802.1p, 63 for DSCP). Yes Downlink QoS Profiles Up to four QoS Profile Names separated by commas, where each name (up to 32 printable characters) is a name of a QoS Profile that exists in the database. The number of entries in the list must be identical to number of entries in Downlink Priority Ranges list. Yes Services - QoS Profiles Parameters 256 Operation NPU Parameters Summary Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated QoS Profile Name Up to 32 printable characters Yes QoS Type 2 - RT Yes 3 - NRT 4 - BE CT Applicable to RT and NRT: Yes 1 - Short 2 - Medium 3 - Long CIR (Kbps) Applicable to RT and NRT: Yes 0 - 12,000 MIR (Kbps) Applicable to NRT and BE: Yes 1 - 12,000. MIR cannot be lower than CIR (NRT) Packet Size (Bytes) Applicable to CG Yes 64 - 1550 (Bytes) Sample Interval (msec) Applicable to CG Yes 5 - 100 (milliseconds) L2 Filtering Rules Parameters L2 Filtering Rule Name Up to 32 printable characters Yes MAC Address MAC address or null for Any Yes MAC Address Mask MAC address Yes MAC Address Direction 1 - Source Yes 2 - Destination Ethertype 4 hexadecimal digits or null for Any Yes L3/L4 Filtering Rules Parameters L3/L4 Filtering Rule Name Up to 32 printable characters Yes IP Address IP address or null for Any Yes IP Address Mask IP address Yes IP Address Direction 1 - Source Yes 2 - Destination BreezeMAX Modular Base Station System Manual 257 Chapter 4 - Operation and Administration Table 4-23: NPU Monitor Parameters Summary Parameter Range Default Run-Time Updated Protocol 0-254 or null for Any Yes Port 0-65534 or null for Any Yes Port Direction 1 - Source Yes 2 - Destination From Wireless Filtering/From Network Filtering Parameters L2 Filtering Rules List - Add L2 Filtering Rule ID Yes L3/L4 Filtering Rules List - Add L3/L4 Filtering Rule ID Yes Active Filtering Rule Type 1 - Layer 2 Layer 2 Yes Disabled Yes Deny Yes 2 - Layer 3/4 Admin Status 1 - Disabled 2 - Enabled Default Action 1 - Deny 2 - Allow MAC Address Deny List Add MAC address (of a device behind SU) 258 Yes Operation A Appendix A - Software Upgrade In This Appendix: “Before you Start” on page 260 “File Loading Procedure” on page 261 “Completing the Software Upgrade (Switching Versions)” on page 263 NOTE Note that AU running SW Version 4.0.2 cannot communicate with SUs running SW Version 4.1, and vice versa, because the air protocol has been changed. To verify proper migration of sectors running SW Version 4.0.2 to SW Version 4.1, refer to the document tytled “Migration from Ver. 4.0.2 to Ver. 4.1 Firmware Upgrade Procedure”. Appendix A - Software Upgrade A.1 Before you Start NOTE This section describes software upgrades using the Monitor program. The upgrade procedure can also be performed using AlvariSTAR or AlvariCRAFT. For instructions on using AlvariSTAR or AlvariCRAFT for software upgrade, refer to relevant section in the AlvariSTAR or AlvariCRAFT User Manual. Loading of new SW files to the unit's FLASH memory can be performed by a simple loading procedure using a TFTP application. Upgrade packages can be obtained from the Technical Support section of Alvarion's web site, http://www.alvarion.com/. Before performing an upgrade procedure, be sure you have the most recent instructions, and that the correct SW files are available in your computer. If you are loading new SU/AU SW files, verify that no more than three SU/AU SW files exist in the NPU. If there are four SU/AU SW files in the unit, one of them must be deleted before loading a new SU/AU SW file. To view the current SU/AU SW files in NPU: Select SU/AU > SW Files in NPU > Show Files. To delete an SU/AU SW file from NPU: Select SU/AU > SW Files in NPU > Delete a File and enter the name of the file to be deleted. 260 BreezeMAX Modular Base Station System Manual File Loading Procedure A.2 File Loading Procedure To load software files: Verify that you have IP connectivity from your computer to the NPU (either the MGMT or the DATA port). To verify the connection, ping the unit's IP address and verify that PING replies are being received. To perform the upgrade, use a DOS TFTP utility with the following syntax: tftp -i hostaddress put sourcefile where -i stands for binary mode and hostaddress is the IP address of the unit to be upgraded (NPU). The put command instructs the PC client to send a file to the hostaddress. sourcefile is the name of the SW file in the PC Client. For example, to load the file npu_4_1_1_4 to the NPU whose IP address is 172.17.31.215, use the following command: tftp -i 172.17.31.215 put npu_4_1_1_4 NOTE It is recommended to upgrade all system elements with the latest software version. Nevertheless, it is possible to upgrade each unit separately and independently. Following a successful completion of the file loading process, the Transfer successful DOS message is displayed. The unit decompresses the loaded file and checks the integrity of the new version. The new version replaces the previous shadow version only after verification. If verification tests fail, the loaded version will be rejected. The unit will reject a file if either the file name or the version number matches the current Main versions. Check that the loaded versions exist in the unit: To view the current NPU SW Versions in the unit: Select Unit Control > SW Versions Control > Show Versions. BreezeMAX Modular Base Station System Manual 261 Appendix A - Software Upgrade To view the current NPU SW Versions in the unit: Select SU/AU > SW Files in NPU > Show Files. 262 BreezeMAX Modular Base Station System Manual Completing the Software Upgrade (Switching Versions) A.3 Completing the Software Upgrade (Switching Versions) After verifying successful upload of all software files, set the new version as the main version in each one of the upgraded system elements: SU(s): Select the SU that should be upgraded. Select Unit Control > SW Versions Control > Set as Main, and enter the new SU SW Version. The unit will reset automatically and will use the new version after power-up. Repeat the process for all SUs that should be upgraded. AU(s): Select the AU that should be upgraded. Select Unit Control > SW Versions Control > Set as Main, and enter the new AU SW Version. The unit will reset automatically. After power-up, the unit will use the new version. Repeat the process for all AUs that should be upgraded. NPU: Select Unit Control > SW Versions Control > Run from Shadow. The system will reset automatically. After power-up, the NPU will run from the new version, that at this stage is still marked as the Shadow Version. To switch versions, select Unit Control > SW Versions Control > Set as Main. BreezeMAX Modular Base Station System Manual 263 B Appendix B - Defining Service Profiles for Generic VoIP Gateways In This Appendix: “Introduction” on page B-266 “1 POTS Basic VoIP G.729 Service Profile” on page B-268 “1 POTS Advanced VoIP G.729 Service Profile” on page B-270 “1 POTS Basic VoIP G.711 Service Profile” on page B-272 “1 POTS Advanced VoIP G.711 Service Profile” on page B-274 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.1 Introduction This section describes the method used for defining the pre-configured Service Profiles for Generic (3rd party) VoIP devices that do not use the DRAP protocol. The same principles can be used for modifying the pre-configured profiles or creating new ones for VoIP services that have different characteristics. B.1.1 Priority Marking We distinguish between two types of Service Profiles for Generic VoIP devices: Marking is not used: This scenario is applicable when the VoIP device behind the SU does not support either DSCP or 802.1p marking to distinguish between different VoIP related traffic types, or when such marking is not used for any reason. The implication is that a single Continuous Grant connection should be used for all VoIP traffic. Marking is used: This scenario is applicable when the VoIP device is capable of marking the different VoIP related traffic types. The assumption is that 3 different priority marks are used: One for RTP traffic, the second for RTCP and VoIP Signaling, and a third one for Data (Device Management). B.1.2 General Assumptions Protocol Header: 18 bytes for Ethernet L2 header (including 4 bytes for VLAN), plus 40 bytes of IP/UDP/RTP headers. A total of 58 bytes. RTCP bandwidth: RFC 3556, Session Description Protocol (SDP) Bandwidth Modifiers for RTP Control Protocol (RTCP) Bandwidth, states that normally, the amount of bandwidth allocated to RTCP in an RTP session is 5% of the session bandwidth. To be on the safe side allocate 10% of the RTP bandwidth to RTCP. VoIP Signaling: Cisco states that its IP Phones generate approximately 150 bps signaling traffic (without L2 overhead). To be on the safe side assume 2 Kbps of VoIP Signaling traffic for each POTS interface. Fax: Fax services are assumed to be based on T.38 Fax Relay. Protocol Header is assumed to be 58 bytes (same as for RTP). Data: Data traffic may include ARP, DHCP, TFTP, SNMP, HTTP and other management protocols. The recommended default bandwidth value is up to 64 266 BreezeMAX Modular Base Station System Manual Introduction Kbps if a Best Effort connection is used for this traffic. If a Continuous Grant service is used for all VoIP related traffic, a lower bandwidth will be allocated to Data traffic. Note that the use of bandwidth consuming protocols when an active call is present should be avoided. BreezeMAX Modular Base Station System Manual 267 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.2 1 POTS Basic VoIP G.729 Service Profile B.2.1 Service Characteristics G.729 codec, 20msec sample interval 1 POTS No Fax Priority marking behind the SU is not used: All VoIP related traffic is classified onto a single Continuous Grant (CG) connection. Multiple media streams to support Call-Waiting: If the traffic exceeds the BW allocated to the CG connection, the SU may request to double the allocated BW. B.2.2 RTP BW Calculation The required bandwidth for a G.729 call (8 Kbps codec bit rate) with RTP and 20 bytes of voice payload is: Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 20 bytes) = 78 bytes Total packet size (bits) = (78 bytes) * 8 bits per byte = 624 bits PPS (Packets Per Second) = (8 Kbps codec bit rate) / (160 bits) = 50 pps Note: 160 bits = 20 bytes (voice payload) * 8 bits per byte Bandwidth per call = Total packet size (624 bits) * 50 pps = 31.2 Kbps B.2.3 RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 31.2 Kbps is 3.12 Kbps. B.2.4 QoS Profile The calculated bandwidth required for RTP traffic is 31.2 Kbps. To accommodate for other traffic types, such as RTCP (up to 3.1 Kbps), Voice Signaling (up to 2 Kbps) and Data (Device Management), we allocate to it a total bandwidth of 31.2 x 1.5=46.8 Kbps (equivalent to a Packet Size of 936 bits, or 117 bytes). The SU may 268 BreezeMAX Modular Base Station System Manual 1 POTS Basic VoIP G.729 Service Profile request twice this BW so it will be allocated with up to approximately 94 Kbps. This is assumed to be sufficient for all traffic scenarios, including Call Waiting. Thus, the CG 47 QoS Profile parameters are: Packet Size: 117 bytes Sample Interval: 20 msec BreezeMAX Modular Base Station System Manual 269 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.3 1 POTS Advanced VoIP G.729 Service Profile B.3.1 Service Characteristics G.729 codec, 20msec sample interval 1 POTS T.38 Fax DSCP priority marking behind the SU is used, with the following values: 63: RTP traffic 26: RTCP and VoIP traffic 0: Data traffic Single media stream to support Call-Waiting B.3.2 Voice RTP BW Calculation The required bandwidth for a G.729 call (8 Kbps codec bit rate) with RTP and 20 bytes of voice payload is: Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 20 bytes) = 78 bytes Total packet size (bits) = (78 bytes) * 8 bits per byte = 624 bits PPS (Packets Per Second) = (8 Kbps codec bit rate) / (160 bits) = 50 pps Note: 160 bits = 20 bytes (voice payload) * 8 bits per byte Bandwidth per call = Total packet size (624 bits) * 50 pps = 31.2 Kbps B.3.3 Voice RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 31.2 Kbps is 3.12 Kbps. B.3.4 T.38 14,400 Kbps Fax RTP BW Calculation The required bandwidth with a 20 msec sample interval is as follows: 270 BreezeMAX Modular Base Station System Manual 1 POTS Advanced VoIP G.729 Service Profile Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 36 bytes) = 94 bytes Total packet size (bits) = (94bytes) * 8 bits per byte = 752 bits PPS = (14.4 Kbps bit rate) / (288 bits) = 50 pps Note: 288 bits = 36 bytes (voice payload) * 8 bits per byte Bandwidth per call = total packet size (752bits) * 50 pps = 37.6 Kbps Since Fax BW is higher than Voice BW, the Fax BW requirement mandates the CG connection's attributes. This is true for all G.729 and G.723 codecs. B.3.5 FAX RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 37.6 Kbps is 3.76 Kbps. B.3.6 QoS Profiles B.3.6.1 CG QoS for RTP Traffic The calculated bandwidth required for RTP traffic is 37.6 Kbps (equivalent to a Packet Size of 752 bits, or 94 bytes). Thus, the CG 38 QoS Profile parameters are: Packet Size: 117 bytes Sample Interval: 20 msec B.3.6.2 RT QoS for RTCP and VoIP Signaling The required bandwidth is 5.76 Kbps (3.76 Kbps for Fax RTCP plus 2 Kbps for VoIP Signaling). We round it up to 6 Kbps. Thus, the required RT 6 QoS Profile parameters are: CIR: 6 Kbps CT: Short B.3.6.3 BE QoS for Data As stated, the recommended QoS Profile for Data is BE 64, with the following parameters: MIR: 64 Kbps CT: Short BreezeMAX Modular Base Station System Manual 271 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.4 1 POTS Basic VoIP G.711 Service Profile B.4.1 Service Characteristics G.711 codec, 20msec sample interval 1 POTS No Fax Priority marking behind the SU is not used: All VoIP related traffic is classified onto a single Continuous Grant (CG) connection. Multiple media streams to support Call-Waiting: If the traffic exceeds the BW allocated to the CG connection, the SU may request to double the allocated BW. B.4.2 RTP BW Calculation The required bandwidth for a G.711 call (64 Kbps codec bit rate) with RTP and 160 bytes of voice payload is: Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 160 bytes) = 218 bytes Total packet size (bits) = (218 bytes) * 8 bits per byte = 1744 bits PPS = (64 Kbps codec bit rate) / (1280 bits) = 50 pps Note: 1280 bits = 160 bytes (voice payload) * 8 bits per byte Bandwidth per call = total packet size (1744 bits) * 50 pps = 87.2Kbps B.4.3 RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 87.2 Kbps is 8.72 Kbps. B.4.4 QoS Profile The calculated bandwidth required for RTP traffic is approximately 88 Kbps. To accommodate for other traffic types, such as RTCP (up to 8.7 Kbps), Voice Signaling (up to 2 Kbps) and Data (Device Management), we allocate to it a total bandwidth of 108 Kbps (equivalent to a Packet Size of 2160 bits, or 270 bytes). The SU may request twice this BW so it will be allocated with up to approximately 272 BreezeMAX Modular Base Station System Manual 1 POTS Basic VoIP G.711 Service Profile 216 Kbps. This is assumed to be sufficient for all traffic scenarios, including Call Waiting. Thus, the CG 108 QoS Profile parameters are: Packet Size: 270 bytes Sample Interval: 20 msec BreezeMAX Modular Base Station System Manual 273 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.5 1 POTS Advanced VoIP G.711 Service Profile B.5.1 Service Characteristics G.729 codec, 20msec sample interval 1 POTS T.38 Fax DSCP priority marking behind the SU is used, with the following values: 63: RTP traffic 26: RTCP and VoIP traffic 0: Data traffic Single media stream to support Call-Waiting B.5.2 Voice RTP BW Calculation The required bandwidth for a G.711 call (64 Kbps codec bit rate) with RTP and 160 bytes of voice payload is: Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 160 bytes) = 218 bytes Total packet size (bits) = (218 bytes) * 8 bits per byte = 1744 bits PPS = (64 Kbps codec bit rate) / (1280 bits) = 50 pps Note: 1280 bits = 160 bytes (voice payload) * 8 bits per byte Bandwidth per call = total packet size (1744 bits) * 50 pps = 87.2Kbps B.5.3 Voice RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 87.2 Kbps is 8.72 Kbps. B.5.4 T.38 14,400 Kbps Fax RTP BW Calculation The required bandwidth with a 20 msec sample interval is as follows: 274 BreezeMAX Modular Base Station System Manual 1 POTS Advanced VoIP G.711 Service Profile Total packet size (bytes) = (Ethernet of 18 bytes) + (IP/UDP/RTP header of 40 bytes) + (voice payload of 36 bytes) = 94 bytes Total packet size (bits) = (94bytes) * 8 bits per byte = 752 bits PPS = (14.4 Kbps bit rate) / (288 bits) = 50 pps Note: 288 bits = 36 bytes (voice payload) * 8 bits per byte Bandwidth per call = total packet size (752bits) * 50 pps = 37.6 Kbps As Fax BW is lower than Voice BW, the Voice BW requirement mandates the CG connection's attributes. This is true for all G.711 codecs. B.5.5 FAX RTCP BW Calculation RTCP BW is 10% of RTP: 10% of 37.6 Kbps is 3.76 Kbps. B.5.6 QoS Profiles B.5.6.1 CG QoS for RTP Traffic The calculated bandwidth required for RTP traffic is 87.2 Kbps (equivalent to a Packet Size of 1744 bits, or 218 bytes). Thus, the CG 88 QoS Profile parameters are: Packet Size: 218 bytes Sample Interval: 20 msec B.5.6.2 RT QoS for RTCP and VoIP Signaling The required bandwidth is 10.72 Kbps (8.72 Kbps for Voice RTCP plus 2 Kbps for VoIP Signaling). We round it up to 611 Kbps. Thus, the required RT 11 QoS Profile parameters are: CIR: 11 Kbps CT: Short BreezeMAX Modular Base Station System Manual 275 Appendix B - Defining Service Profiles for Generic VoIP Gateways B.5.6.3 BE QoS for Data As stated, the recommended QoS Profile for Data is BE 64, with the following parameters: MIR: 64 Kbps CT: Short 276 BreezeMAX Modular Base Station System Manual Glossary AAA Authentication, Authorization, and Accounting (Pronounced "triple a."). A system (or several systems) that controls what resources users have access to, and keeps track of the activity of users over the network. ANSI American National Standards Institute. A voluntary organization composed of corporate, government, and other members that coordinates standards-related activities, approves U.S. national standards, and develops positions for the United States in international standards organizations. ARP Address Resolution Protocol. Internet protocol used to map an IP address to a MAC address. Defined in RFC 826. ARQ Automatic Repeat reQuest. A communication technique in which the receiving device detects errors and requests retransmissions. ASCII American Standard Code for Information Interchange. A code for representing English characters as numbers, with each letter assigned a number from 0 to 127. ATM Asynchronous Transfer Mode. A network technology that dynamically allocates bandwidth. ATM uses fixed-size data packets and a fixed channel between two points for data transfer. ATM was designed to support multiple services such as voice, graphics, data, and full-motion video. It allows service providers to dynamically assign bandwidth to individual customers. ATPC Automatic Transmit Power Control AU Access Unit AVU Air Ventilation Unit BE Best effort. A service where neither throughput nor delay guarantees are provided. The subscriber unit sends requests for bandwidth in either random access slots or dedicated transmission opportunities. The occurrence of dedicated opportunities is subject to network load, and the subscriber unit cannot rely on their presence. Service parameters include Committed Time (CT) and Maximum Information Rate (MIR). Glossary BER Bit Error Rate. In a digital transmission, BER is the percentage of bits with errors divided by the total number of bits that have been transmitted, received or processed over a given time period. BPSK Binary Phase-Shift Keying. A data transfer technique. BPSK transmits data using two phase modulation signals, one phase representing a binary one, and the other representing a binary zero. The signal is divided into bits; their status is determined by the preceding wave. If the wave changes, for example, the signal is reversed. BST Base Station BW Bandwidth BWA Broadband Wireless Access CBR Constant Bit-Rate CG Continuous Grant. Also known as Unsolicited Grant Services (UGS), is tailored for carrying constant bit- rate (CBR) real-time services characterized by fixed size data packets on a periodic basis such as VoIP or E1/T1. Service parameters include unsolicited grant size (packet size) and normal grant interval (sample interval). CIR Committed Information Rate. The rate (in bits per second) at which a network guarantees to transfer information under normal conditions, averaged over a minimum increment of time. cPCI Compact Peripheral Component Interface. a new standard for computer backplane architecture and peripheral integration, defined and developed by the peripheral component interconnect (PCI) industrial computers manufacturers group (PICMG). Designed to provide rugged, high-density systems. CPE Customer Premise Equipment. Communications equipment that resides on the customer's premises. CPLD Complex Programmable Logic Device CRC Cyclical Redundancy Check. A common technique for detecting data transmission errors, in which the frame recipient calculates a remainder by dividing frame contents by a prime binary divisor and compares the calculated remainder to a value stored in the frame by the sending equipment. CS Convergence Sublayer. Particular protocols that are responsible for gathering and formatting higher layer information so it can be processed by the lower layers. 278 BreezeMAX Modular Base Station System Manual Glossary CSMA/CD Carrier Sense Multiple Access with Collision Detection. Media-access mechanisms wherein devices ready to transmit data first check the channel for a carrier. If no carrier is sensed for a specific period of time, a device can transmit. If two devices transmit at once, a collision occurs and is detected by all colliding devices. This collision subsequently delays retransmissions from those devices for some random length of time. Ethernet and IEEE 802.3 use CSMA/CD access. CT Committed Time. The time interval used for measuring average information transfer rates. DHCP Dynamic Host Configuration Protocol. A protocol for dynamically assigning IP addresses from a pre-defined list to nodes on a network. Using DHCP to manage IP addresses simplifies client configuration and efficiently utilizes IP addresses. DIP Switch A group of subminiature switches mounted in a Dual Inline Package compatible with standard integrated-circuit sockets. DL Down Link DOS Disk Operating System DRAP Dynamic Resources Allocation Protocol DSCP Differentiated Service Code Point, AKA DiffServ: An alternate use for the ToS byte in IP packets. Six bits of this byte are being reallocated for use as the DSCP field where each DSCP specifies a particular per-hop behavior that is applied to the packet. DiffServ See DSCP DLI Data Loss Indicator EIR Excess Information Rate. Specifies the excess rate (above the committed rate) of information that can be available to a user. The EIR is used by the traffic policing mechanism to prevent users from sending excess traffic to the network. (EIR = MIR-CIR). EIRP Equavalent Isotropic Radiated Power. The apparent power transmitted towards the receiver, if it is assumed that the signal is radiated equally in all directions. The EIRP is equal to the power (in dBm) at the antenna port, plus the power gained from the directivity of the antenna (in dBi). BreezeMAX Modular Base Station System Manual 279 Glossary EMC Electro-Magnetic Compatibility. The capability of equipment or systems to be used in their intended environment within designed efficiency levels without causing or receiving degradation due to unintentional EMI (Electro Magnetic Interference). EMC generally encompasses all of the electromagnetic disciplines. ETSI European Telecommunications Standards Institute. A non-profit organization producing voluntary telecommunications standards used throughout Europe, some of which have been adopted by the EC as the technical base for Directives or Regulations. FCC Federal Communications Commission. A U.S. government agency that supervises, licenses, and controls electronic and electromagnetic transmission standards. FDD Frequency Division Duplex. Full duplex operation by using a pair of frequencies, one for transmission and one for reception. FEC Forward Error Correction. A method of communicating data that can corrects errors in transmission on the receiving end. Prior to transmission, the data is put through a predetermined algorithm that adds extra bits specifically for error correction to any character or code block. If the transmission is received in error, the correction bits are used to check and repair the data. FFT Fast Fourier Transform. An algorithm for converting data from the time domain to the frequency domain; often used in signal processing. FTP File Transfer Protocol. A protocol for exchanging files over the Internet. FTP uses the Internet's TCP/IP protocols to enable data transfer. G.711 A 64 Kbps PCM voice-coding technique. Described in the ITU-T standard in its G-series recommendations. G.723.1 A compression technique that can be used for compressing speech or audio signal components at a very low bit rate as part of the H.324 family of standards. This codec has two bit rates associated with it: 5.3 and 6.3 Kbps. The higher bit rate provides a somewhat higher quality of sound. The lower bit rate provides system designers with additional flexibility. Described in the ITU-T standard in its G-series recommendations. 280 BreezeMAX Modular Base Station System Manual Glossary G.729 A compression technique where voice is coded into 8 Kbps streams. There are two variations of this standard (G.729 and G.729 Annex A) that differ mainly in computational complexity; both provide speech quality similar to 32-kbps ADPCM. Described in the ITU-T standard in its G-series recommendations. GPS Global Positioning System. A system that uses satellites, receivers and software to allow users to determine their precise geographic position. H.323 A protocol suite defined by ITU-T for voice transmission over internet (Voice over IP or VoIP). In addition to voice applications, H.323 provides mechanisms for video communication and data collaboration, in combination with the ITU-T T.120 series standards. IB In-Band IDU Indoor Unit IEEE Institute of Electrical and Electronics Engineers. IEEE (pronounced I-triple-E) is an organization composed of engineers, scientists, and students. The IEEE is best known for developing standards for the computer and electronics industry. In particular, the IEEE 802 standards for local-area networks are widely followed. IEEE 802.11b The IEEE 802.11b (also referred to as 802.11 High Rate or Wi-Fi). An extension to 802.11 standard for wireless Ethernet networks, that applies to wireless LANS and provides 11 Mbps transmission (with a fallback to 5.5, 2 and 1 Mbps) in the 2.4 GHz band. IEEE 802.11g An extension to 802.11 standard for wireless Ethernet networks, that applies to wireless LANs and provides 20+ Mbps in the 2.4 GHz band. IEEE 802.16 Also known as WIMAX. A group of broadband wireless communications standards for metropolitan area networks (MANs) developed by a working group of the IEEE. IEEE 802.16e 802.16e, also known as 802.16-2005, is an IEEE standard addressing mobility of wireless broadband (WiMax). IEEE 802.16e is sometimes called Mobile WiMAX, after the WiMAX forum for interoperability. 802.16e, based on an existing WiMAX standard 802.16a, adds WiMAX mobility in the 2-to-6 GHz-licensed bands. 802.16e allows for fixed wireless and mobile Non Line of Sight (NLOS) applications primarily by enhancing the OFDMA (Orthogonal Frequency Division Multiple Access). BreezeMAX Modular Base Station System Manual 281 Glossary IEEE 802.1p A QoS method - A three-bit value that can be placed inside an 802.1Q frame tag. IEEE 802.1Q The IEEE 802.1Q standard defines the operation of VLAN Bridges that permit the definition, operation and administration of Virtual LAN topologies within a Bridged LAN infrastructure. The 802.1Q specification establishes a standard method for inserting VLAN membership information into Ethernet frames. A tag field containing VLAN (and/or 802.1p priority) information can be inserted into an Ethernet frame, carrying VLAN membership information. IEEE 802.3 A Local Area Network protocol suite commonly known as Ethernet. Ethernet uses Carrier Sense Multiple Access bus with Collision Detection CSMA/CD. This method allows users to share the network cable. However, only one station can use the cable at a time. A variety of physical medium dependent protocols are supported. IETF Internet Engineering Task Force. One of the task forces of the IAB (Internet Architecture Board), formally called the Internet Activities Board, which is the technical body that oversees the development of the Internet suite of protocols (commonly referred to as "TCP/IP").The IETF is responsible for solving short-term engineering needs of the Internet. IF Intermediate Frequency. Radio communications systems modulate a carrier frequency with a baseband signal in order to achieve radio transmission. In many cases, the carrier is not modulated directly. Instead, a lower IF signal is modulated and processed. At a later circuit stage, the IF signal is converted up to the transmission frequency band. IP Internet Protocol. The standard that defines how data is transmitted over the Internet. IP bundles data, including e-mail, faxes, voice calls and messages, and other types, into "packets", in order to transmit it over public and private networks. IPsec Security Architecture for IP Network. IP Control Protocol (IPCP) and IPv6 Control Protocol IPsec provides security services at the IP layer by enabling a system to select required security protocols, determine the algorithm(s) to use for the service(s), and put in place any cryptographic keys required to provide the requested services. IPsec can be used to protect one or more "paths" between a pair of hosts, between a pair of security gateways, or between a security gateway and a host. ISP Internet Service Provider 282 BreezeMAX Modular Base Station System Manual Glossary ITU-T International Telecommunication Union - Telecommunications. An intergovernmental organization through which public and private organizations develop telecommunications. The ITU was founded in 1865 and became a United Nations agency in 1947. It is responsible for adopting international treaties, regulations and standards governing telecommunications. The standardization functions were formerly performed by a group within the ITU called CCITT, but after a 1992 reorganization the CCITT no longer exists as a separate entity. L2TP Layer 2 Tunneling Protocol. An extension to the PPP protocol that enables ISPs to operate Virtual Private Networks (VPNs). L2TP merges the best features of two other tunneling protocols: PPTP from Microsoft and L2F from Cisco Systems. Like PPTP, L2TP requires that the ISP's routers support the protocol. LAN Local area Network. A computer network limited to a small geographical area, such as a single building. The network typically links PCs as well as shared resources such as printers. LED Light Emitting Diode. LOS Line Of Sight. A condition where a signal travels over the air directly from a wireless transmitter to a wireless receiver without passing an obstruction. LVDS Low Voltage Differential Signaling. A low noise, low power, low amplitude method for high-speed (gigabits per second) data transmission over copper wire. MAC Media Access Control. The lower of the two sub-layers of the data link layer defined by the IEEE. The MAC sub-layer handles access to shared media, such as whether token passing or contention will be used. MAC Address Standardized data link layer address that is required for every port or device that connects to a LAN. Other devices in the network use these addresses to locate specific ports in the network and to create and update routing tables and data structures. MAC addresses are 6bytes long and are controlled by the IEEE. MAN Metropolitan Area Network. A data network designed for a town or city. In terms of geographic breadth, MANs are larger than local-area networks (LANs), but smaller than wide-area networks (WANs). BreezeMAX Modular Base Station System Manual 283 Glossary MCS Multipoint Communications Systems. Applications licensed at 2500 MHz in Canada. A wide variety of applications are possible, including one-way and two-way transmission and a diversity of distribution capacities. MD5 A Message-Digest algorithm developed by RSA Laboratories used for creating unforgeable digital signatures. MD5 produces an 128-bit (16 byte) message digest. Most existing software applications that handle certificates only support MD5. MIB Management Information Base. A database of objects that can be monitored by a network management system. SNMP uses standardized MIB formats that allow any SNMP tools to monitor any device defined by a MIB. MIR Maximum Information Rate. Specifies the maximum rate of information that can be available to a user. The MIR is used by the traffic policing mechanism to prevent users from sending excess traffic to the network. MMDS Multichannel Multipoint Distribution Service. MMDS is a licensed wireless service that has the capability to provide broadband access. MMDS operates in several parts of the 2 GHz spectrum. MRRC Maximum Receive Ratio Combining. NA Not Available or Not Applicable NAS Network Access Server. A Network Access Server operates as a client of RADIUS. The client is responsible for passing user information to designated RADIUS server(s(, and then acting on the response. NAT Network Address Translation. Basic Network Address Translation (Basic NAT) is a method by which IP addresses are mapped from one group to another, transparent to end users. Network Address Port Translation, or NAPT is a method by which many network addresses and their TCP/UDP ports are translated into a single network address and its TCP/UDP ports. Together, these two operations, referred to as traditional NAT, provide a mechanism to connect a realm with private addresses to an external realm with globally unique registered addresses. NIC Network Interface Card. An expansion board you insert into a computer (or a built-in component) that enables the computer to connect to a network. Most NICs are designed for a particular type of network, protocol, and media, although some can serve multiple networks. 284 BreezeMAX Modular Base Station System Manual Glossary NIU Network Interface Unit NLOS Non Line Of Sight. A condition where a signal from a wireless transmitter passes several obstructions before arriving at a wireless receiver. The signal may be reflected, refracted, diffracted, absorbed or scattered. These create multiple signals that will arrive at a receiver at different times, from different paths, and with different strength. Consequently, wireless systems developed for NLOS environment have to incorporate a number of techniques to overcome this problem and that make the systems more complex than those for LOS. But NLOS capable systems simplify network planning and site acquisition. NMS Network Management System. A system responsible for managing at least part of a network. An NMS is generally a reasonably powerful and well-equipped computer, such as an engineering workstation. NMSs communicate with agents to help keep track of network statistics and resources. NOC Network Operations Center. The physical space from which a typically large telecommunications network is managed, monitored and supervised. NPU Network Processing Unit NRT Non Real Time. is very similar to the Real-Time polling service except that connections may utilize random access transmit opportunities for sending bandwidth requests. These Non Real Time Variable Bit Rate (NRT-VBR) services, such as file transfer and Internet access with a minimum guaranteed rate, are characterized by requirement for a guaranteed rate, but can tolerate longer delays and are rather insensitive to jitter. Service parameters include CIR, Committed Time (CT), and MIR that limit the rate as otherwise bandwidth intensive services may expand to occupy full bandwidth. OA&M Operation, Administration & Maintenance. Provides the facilities and the personnel required to manage a network. ODU Outdoor Unit OFDM Orthogonal Frequency Division Multiplexing: A method for multiplexing signals, which divides the available bandwidth into a series of frequencies known as tones. Orthogonal tones do not interfere with each other when the peak of one tone corresponds with the null. The rapid switching, frequency-hopping technique is intended to allow more robust data service. BreezeMAX Modular Base Station System Manual 285 Glossary OFDMA Orthogonal Frequency Division Multiple Access. It’s a logical extension of OFDM and a modulation/multiple access technique. OFDMA divides a signal into sub-channels (i.e. groups of carriers), with each sub-channel (or several sub-channels) being allocated to a different subscriber. OOB Out-Of-Band PAP Password Authentication Protocol. A means of authenticating passwords which is defined in RFC 1334. PAP uses a two-way handshaking procedure. The validity of the password is checked at login. PER Packet Error Rate. In a digital transmission, PER is the percentage of packets with errors divided by the total number of packets that have been transmitted, received or processed over a given time period. PHY PHYsical Layer. The physical, or lowest, layer of the OSI Network Model. In a wireless network, the PHY defines parameters such as data rates, modulation method, signaling parameters, transmitter/receiver synchronization, etc. Within an actual radio implementation, the PHY corresponds to the radio front end and baseband signal processing sections. PIU Power Interface Unit POTS Plain Old Telephone System. A basic analog telephone equipment. PSU Power Supply Unit PPPoE Point-to-Point Protocol over Ethernet. PPPoE relies on two widely accepted standards: PPP and Ethernet. PPPoE is a specification for connecting the users on an Ethernet to the Internet through a common broadband medium, such as a single DSL line, wireless device or cable modem. All the users over the Ethernet share a common connection, so the Ethernet principles supporting multiple users in a LAN combines with the principles of PPP, which apply to serial connections. QAM Quadrature Amplitude Modulation. A technique used in wireless applications to double the available bandwidth by combining two amplitude-modulated signals. The two combined signals differ in phase by 90 degrees; this technique doubles the bandwidth by combining the two signals at the source before transmission, transmitting digital data at a rate of 4 bits per signal change. 286 BreezeMAX Modular Base Station System Manual Glossary QoS Quality of Service. Measure of performance for a transmission system that reflects its transmission quality and service availability. QPSK Quadrature Phase Shift Keying. A data transfer technique used in coaxial cable networks that sends data using modulating signals. Four different phases represent data, with each signal's information determined by the signal before it. For example, if a phase stays the same from one signal to the other, the information has not changed. RADIUS Remote Authentication Dial-In User Service, an authentication and accounting system used by many Internet Service Providers (ISPs). When you connect to the system you must enter your username and password. This information is passed to a RADIUS server, which checks that the information is correct, and then authorizes access to the system. RF Radio frequency. An AC signal of high enough frequency to be used for wireless communications. RFC Request For Comments. The name of the result and the process for creating a standard on the Internet. New standards are proposed and published on the Internet, as a Request For Comments. The proposal is reviewed by the Internet Engineering Task Force. RoHS Restriction of the use of certain Hazardous Substances in electrical and electronic equipment, reference EC Directive 2002/95/EC of 27 January 2003. RS-232 A serial interface published by the EIA (Electronic Industries Association) for asynchronous data communication over distances up to a few hundred feet. Characterized by a single-ended (not differential) physical layer, it uses one signal wire for transmission, another for reception, and a common wire (ground), plus some timing and control signals. RS-422 RS-422 is a serial interface standard in which data is sent in a differential pair (two wires, or twisted pair cable), which allows greater distances and higher data rates than non-differential serial schemes such as RS-232. BreezeMAX Modular Base Station System Manual 287 Glossary RSA A public-key encryption technology developed by RSA Data Security, Inc. The acronym stands for Rivest, Shamir, and Adelman, the inventors of the technique. The RSA algorithm is based on the fact that there is no efficient way to factor very large numbers. Deducing an RSA key, therefore, requires an extraordinary amount of computer processing power and time. The RSA algorithm has become the de facto standard for industrial-strength encryption, especially for data sent over the Internet. RSSI Received Signal Strength Indicator. A signal or circuit that indicates the strength of the incoming (received) signal in a receiver. R&TTE Radio & Telecommunications Terminal Equipment. The R&TTE Directive 1999/5/EC governs the marketing and use of R&TTE equipment. With the exception of a few categories of equipment, the Directive covers all equipment, which uses the radio frequency spectrum. It also covers all terminal equipment attached to public telecommunication networks. RT Real Time. Real Time service is designed to meet the needs of Real Time Variable Bit Rate (RT-VBR) like services characterized by requirements for guaranteed rate and delay such as streaming video or audio. These services are dynamic in nature, but offer periodic dedicated requests opportunities to meet real-time requirements. Because the subscriber equipment issues explicit requests, the protocol overhead and latency is increased, but capacity is granted only according to the real needs of the connection. Service parameters include CIR and CT. RTCP RTP Control Protocol. A protocol that monitors the QoS of an RTP connection and conveys information about the on-going session. RTP Real Time Protocol. An Internet protocol for transmitting real-time data such as audio and video. RTP itself does not guarantee real-time delivery of data, but it does provide mechanisms for the sending and receiving applications to support streaming data. Typically, RTP runs on top of the UDP protocol, although the specification is general enough to support other transport protocols. Rx Receive 288 BreezeMAX Modular Base Station System Manual Glossary SIP Session Initiation Protocol. An application-layer control IETF protocol that can establish, modify, and terminate multimedia sessions such as Internet telephony calls (VoIP). SIP can also invite participants to already existing sessions, such as multicast conferences. Media can be added to (and removed from) an existing session. SIP transparently supports name mapping and redirection services, which supports personal mobility - users can maintain a single externally visible identifier regardless of their network location. SLA Service Level Agreement. A contract between a service provider and the end user, which stipulates and commits the service provider to a required level of service. An SLA relates to issues such as specified level of service, support options, enforcement or penalty provisions for services not provided, a guaranteed level of system performance as relates to downtime or uptime, a specified level of customer support and what software or hardware will be provided and for what fee. SME Small and Medium-sized Enterprises. SMEs are small-scale entrepreneurial private enterprises: they are usually defined as having less than 250 employees, but most have far fewer. SNAP Sub Network Access Protocol SNMP Simple Network Management Protocol. A network management protocol that provides a means to monitor and control network devices, and to manage configurations, statistics collection, performance, and security. SNMP works by sending messages, called protocol data units (PDUs), to different parts of a network. SNMP-compliant devices, called agents, store data about themselves in Management Information Bases (MIBs) and return this data to the SNMP requesters. SNR Signal to Noise Ratio. The ratio of the amplitude of a desired analog or digital data signal to the amplitude of noise in a transmission channel at a specific point in time. SNR is typically expressed logarithmically in decibels (dB). SNR measures the quality of a transmission channel or a signal over a network channel. The greater the ratio, the easier it is to identify and subsequently isolate and eliminate the effects of noise. SNR also is abbreviated as S/N. BreezeMAX Modular Base Station System Manual 289 Glossary SOHO Small Office Home Office. A term that refers to the small or home office environment and the business culture that surrounds it. Typically it refers to an office or business with ten or fewer computers and/or employees. SRC Source SU Subscriber Unit TCP Transmission Control Protocol. Connection-oriented transport layer protocol that provides reliable full-duplex data transmission. TCP is the part of the TCP/IP suite of protocols that is responsible for forming data connections between nodes that are reliable, as opposed to IP, which is connectionless and unreliable. TCP/IP Transmission Control Protocol/Internet Protocol. A set of protocols developed by the U.S. Department of Defense to allow communication between dissimilar networks and systems over long distances. TCP/IP is the de facto standard for data transmission over networks, including the Internet. TDD Time Division Duplex is a duplexing technique dividing a radio channel in time to allow downlink operation during part of the frame period and uplink operation in the remainder of the frame period. TDM Time Division Multiplexing. Technique in which information from multiple channels can be allocated bandwidth on a single link based on pre-assigned time slots. Bandwidth is allocated to each channel regardless of whether the station has data to transmit. TFTP Trivial File Transfer Protocol. Simplified version of FTP that allows files to be transferred from one computer to another over a network, usually without the use of client authentication. TTL Time To Live Tx Transmit A unit for measuring the height in rack cabinets. 1U = 1.75 inches. UDP User Datagram Protocol. Connectionless transport layer protocol in the TCP/IP protocol stack. UDP is a simple protocol that exchanges datagrams without acknowledgments or guaranteed delivery, requiring that error processing and retransmission be handled by other protocols. UDP is defined in RFC 768. UL Up Link 290 BreezeMAX Modular Base Station System Manual Glossary UTC Coordinated Universal Time. The reference for the official time used by all countries in the world, and it is independent from the time zones. The modern implementation of Greenwich Mean Time. VLAN Virtual Local Area Network. A group of devices on one or more LANs that are configured with the same VLAN ID so that they can communicate as if they were attached to the same wire, when in fact they are located on a number of different LAN segments. Used also to create separation between different user groups. VLSI Very Large Scale Integration. The process of placing thousands (or hundreds of thousands) of electronic components on a single chip. VoIP Voice over Internet Protocol. Provides an advanced digital communications network that bypasses the traditional public switched telephone system and uses the Internet to transmit voice communication. VoIP enables people to use the Internet as the transmission medium for telephone calls by sending voice data in packets using IP rather than by traditional circuit switched transmissions of the PSTN. VPL Virtual Private Link. A virtual connection between two points on the network, such as a base station and a service provider or corporate network. Identified by the VPL ID, with functionality that is similar to VLAN ID (VLAN on the backbone network). VPN Virtual Private Network. A private network of computers that's at least partially connected by public lines. A good example would be a private office LAN that allows users to log in remotely over the Internet (an open, public system). VPNs use encryption and secure protocols like PPTP to ensure that data transmissions are not intercepted by unauthorized parties. WAN Wide Area Network. A computer network that spans a relatively large geographical area. Wide area networks can be made up of interconnected smaller networks spread throughout a building, a state, or the entire globe. WCS Wireless Communications Services. The variety of services available using frequencies in the 2.3 GHz band for general fixed wireless use. BreezeMAX Modular Base Station System Manual 291 WEEE Waste Electronic and Electrical Equipment. The purpose of Directive 2002/96/EC on waste electrical and electronic equipment (WEEE) is, as a first priority, the prevention of waste electrical and electronic equipment (WEEE), and in addition, the reuse, recycling and other forms of recovery of such wastes so as to reduce the disposal of waste. It also seeks to improve the environmental performance of all operators involved in the life cycle of electrical and electronic equipment, e.g. producers, distributors and consumers and in particular those operators directly involved in the treatment of waste electrical and electronic equipment. WIMAX The name commonly given to the IEEE 802.16 standard. Specifications for fixed broadband wireless metropolitan access networks (MANs) that use a point-to-multipoint architecture. WIMAX supports very high bit rates in both uploading to and downloading from a base station up to a distance of 30 miles. Index Actual Tx Power, Numerics 1 POTS Advanced VoIP G.711 Pre-Configured Profile, 148 Add Accounting Server, 120 117 1 POTS Advanced VoIP G.729 Pre-Configured Profile, Authorized Manager, 138 238 New SU, 198 1 POTS Basic VoIP G.711 Pre-Configured Profile, 238 ODU, 148 1 POTS Basic VoIP G.729 Pre-Configured Profile, 237 Radio Cluster, 144 802.1p Marking Mode, 220 Add New SU, 198 238 Authentication Server, Add Server Access Unit Indoor Module, Access VLAN, Accounting, 51 214 Address, Accounting 120 Add Server, 120 Delete Selected Server, Channel, 121 150 Service, 214 Subscriber, 211 120 120 Server Status, 120 Show All, 120 Show Selected Server, 121 Statistics, 121 UDP Port, 120 Accounting Parameters, 119 Trap Configuration, 111 Administrator Password, 127 Advanced Service Mode, 202 Air Ventilation Unit, 59 Alarms and Traps, 110 Altitude, 109 Antenna Selection, 180 Associated ODU, 165 Associated Radio Cluster, 148 ATPC Enable/Disable, 103 ATPC Parameters, 102 Action 183 Active Alarms 110 Active Rule Type, 232 153 AU Active Voice Calls, Bandwidth, Activity Status 163 Base Station ID Parameters, Accounting, 120 Authentication, 117 Actual Maximum Cell Radius (km), 233 ODU, 120 Select Server, Show, 166 Interface Filtering, Operation Status, SU SW File, 185 Admin Status Activity Status, IP Address, 120 117 Authentication, Configuration Menu, 163 162 161 Configured Action, 152 Configured SU Operation, 153 Index Configured SU SW File Name, 153 Configured SU SW Version, 153 Configured SW File Name, 152 Configured SW Version, 152 Default SW File (Adv-Si), 155 Default SW File (Std), 154 IDU Type, 153 MAC Parameters, 161 Maximum Number of Voice Calls, 169 Menu, 152 Multirate Parameters, 167 Operation Mode, 153 Performance Monitoring, 170 Phy Parameters, 163 Replacing, 61 Reset Unit, 158 Select, 156 Set Factory Defaults, 159 Show Summary, 152 SU SW File, 161 SW Download Status, 152 SW File, 160 SW Files in NPU, 154 SW Versions Control, 159 Unit Control, 158 Voice Parameters, 169 AU IDU Type, 153 AU Minimum Allocation, 169 AU Slot # 156 Show, 156 AU Wireless Port Counters, 51 56 Inserting, 55 LEDs, 52 IP Address, 118 117 Operation Status, 117 Select Server, 118 Server Status, 118 Show All, 117 Show Selected Server, 118 Statistics, 118 UDP Port, 118 Authentication Parameters, 117 Authorized Managers Add, 138 IP Address, 138 Parameters, 137 Read Community, 138 Select, 138 Send Traps, 138 Show All, 138 Write Community, AVU, 138 59 LEDs, 59 Replacing, 59 Back Panel Port Counters, 170 Backup File BS License File, 130 171 130 Filtering, 130 Full, 130 Profiles, 130 Traps, 130 130 Upload/Download, 131 Bandwidth AU-ODU AU, Connectors, 39 Installation, 32 LEDs, 39 163 SU (Phy Standard FDD Parameters), 186 SU (Radio Parameters, Advanced Si), 193 Base Station Authentication 294 Delete Selected Server, Profiles and Services, Ejecting, Activity Status, 117 Creating, Menu, AU-IDU, Add Server, Chassis, 117 42 Chassis Slot Assignment, 98 BreezeMAX Modular Base Station System Manual Index Configuration Menu, Installation, Associated Radio Cluster, 98 41 Power Cable for High-Power (58A) PIU, Power Cable for regular (35A) PIU, Power Requirements, Show, 48 47 43 97 Base Station ID AU, 162 SU (MAC Standard FDD Parameters), 186 Base Station ID Mask SU (MAC Standard FDD Parameters), Base Station Licenses, Basic Parameters, BE, 186 Clear All Configured SU SW Files SU, 123 198 Clear All Configured SU SW Files for this AU, 74 Clear Best AU Table, 227 BER Test, 167 Downlink (Tx) Frequency, 165 Frequency Band, 167 Select, 165 Tx Power, 166 Uplink (Rx) Frequency, 167 Chassis, 42 Slot Assignment, 98 CIR, 229 Clear All Configured AU SW Files, 155 192 Clock Parameters, 106 171 Best BST/AU Parameters, Committed Information Rate, 190 Best BST/AU Support, 192 Best BST/AU Table, 191 Best Effort (BE) Qos Profile, 227 Committed Time, 228 Configuration AU, Bridge Aging Time 161 Base Station Parameters, 98 NPU, NPU, 138 SU, 190 132 SU, 184 Bridging Parameters (SU), Broadcast Relaying, 229 Configured Action 189 AU, 224 Bronze LAN-to-LAN Pre-Configured Profile, 237 Bronze Teleworking Pre-Configured Profile, 237 BST/AU ID, 192 BST/AU ID Mask, 192 Burst Error Rate Counters 152 SU, 173 Configured SU Action AU, 153 Configured SU SW File Name AU, 153 Configured SU SW Version AU, 171 SU, 197 AU, 153 Configured SW File Name AU, Calculated Local Date and Time, 109 Cell ID, 104 CG, 227 Chain Number, 107 Chain Parameters, 107 Change Password, 127 Channel Admin Status, 166 Associated ODU, 165 BreezeMAX Modular Base Station System Manual 152 SU, 173 Configured SW Version AU, 152 SU, 173 Configured Tx Power, 146 Connectors AU-ODU, 39 GPS Adapter, 68 NPU, 54 295 161 Index ODU Power Feeder, AU, 64 Continuous Grant (CG) QoS Profile, 154 SU, 176 227 Counters Defining Local Service Profiles, AU Ports, Defining Local Services, 170 Back Panel Port, 235 236 Delete 170 Burst Error Rate (AU), Accounting Server, 171 Burst Error Rate (SU), 197 Data Port, 140 Management Port, 141 Service, 214 SU Ethernet Port, 196 SU Port, 196 Wireless Port (AU), 171 Wireless Port (SU), 197 Country, 185 CPEs License Bank, 122 Create Backup, 130 CT, 228 121 AU SW File (in NPU), 155 Authentication Server, 118 ODU, 148 SU, 198 SU SW File, 177 Dest Subnet, 134 Dest Subnet Mask, 134 Device Location, 99 Device Name, 99 Discrete Frequencies, 194 DL-UL Ratio, 105 Downlink (Tx) Frequency (Channel), 165 Downlink Basic Rate (AU), Downlink QoS Profiles, Downlink Upper Priority Limits, Data Port Auto Negotiation Option, Description, 136 IP Address, 135 Management VLAN, 136 135 136 Subnet Mask, 135 Data Port Counters, 140 Days, 110 DC Power Cable 65 Default Action 210 Default PPPoE Service Profile, 210 Default SW File (Adv-Si) 155 SU, 176 Default SW File (Std) 296 AU-IDU, 56 56 PIU (with HOT SWAP), 233 Default L2/Voice Service Profile, AU, NPU, 139 Interface Filtering, 136 Eject ODU Power Feeder, Debug Stream, 201 138 DSCP Marking Mode, 220 Duplex Mode, 104 Duplex Parameters, 104 Duplicate Sessions, 203 Duplicate SU Name, 174 DRAP TTL Retries, Management Traffic Enable/Disable, Parameters, 226 DRAP 136 Gateway, Speed, 169 226 56 PIU (without HOT SWAP), PSU, 56 56 Enable/Disable Limit on Number of Supported Devices (SU), 190 End Downlink (Rx) Frequency, Ethernet Port (SU), 195 188 Ethernet Port Auto Negotiation BreezeMAX Modular Base Station System Manual Index SU, GPS Adapter 189 Ethernet Port Speed and Duplex SU, Connectors, 68 Installation, 67 LEDs, 69 GPS Info, 109 GPS Protocol, 108 GPS Supported, 108 Grace Licenses, 123 189 Ethertype (L2 Filtering Rule), 230 External 16MHz Clock, 107 External 1PPS Clock, 106 File Loading Procedure, 261 Filtering Rules Menu, Hold Over Passed Timeout, 229 210 First Name, HOT SWAP, Forwarding Rule Hybrid VLAN Mode, Broadcast Relaying, Definition, Menu, 213 224 200 222 Multicast QoS Profile, Name, 108 44 IDU Type, 173 IF Cables, 33 224 223 Insert Service Type, 223 Unicast Relaying, 223 Unknown Forwarding Policy, AU-IDU, 224 Forwarding Rule Class, 224 Forwarding Rule Name, 223 Frequency Bands File, 150 Frequency Bands Groups, 150 Frequency Scanning Parameters, From Network Filtering, From Wireless Filtering, 55 PIU (with HOT SWAP), 55 PIU (without HOT SWAP), 56 PSU, 56 Inserting NPU, 193 232 232 55 Installation, 31 AU-ODU, 32 Base Station, 41 GPS Adapter, 67 ODU Power Feeder, 63 Installer Password Gateway NPU, Data Port, SU, 136 Management Port, Interface Filtering 133 General Service Parameters Active Rule Type, Default L2/Voice Service Profile, Default PPPoE Service Profile, Menu, Show, 210 210 232 Admin Status, 233 Default Action, 233 From Network Filtering, 209 Service Mode, 127 189 210 209 210 Update, Gold LAN-to-LAN Pre-Configured Profile, 237 Gold Teleworking Pre-Configured Profile, 237 BreezeMAX Modular Base Station System Manual 232 From Wireless Filtering, 232 L2 Filtering Rules List, 232 L3/L4 Filtering Rules List, 232 Menu, 232 Interface Type, 180 297 Index Internet Access L2 Pre-Configured Profile, 237 Internet Access PPPoE Pre-Configured Profile, 237 NPU, IP Address PIU, Accounting Server, 120 Authentication Server, 117 Authorized Managers, 138 Data Port, 135 L3/L4 Filtering Rule, 231 Management Port, 133 IP Address Direction (L3/L4 Filtering Rule), 231 IP Address Mask (L3/L4 Filtering Rule), 231 54 ODU Power Feeder, 65 47 50 Longitude, 109 Loop, 173 PSU, MAC (Standard FDD) Parameters SU, 185 MAC Address (L2 Filtering Rule), MAC Address Control Number, 230 178 MAC Address Direction (L2 Filtering Rule), Keep Alive Timeout, 116 230 MAC Address Mask (L2 Filtering Rule), 230 MAC Addresses Deny List, 235 MAC Parameters L2 Filtering Rules Ethertype, 230 MAC Address, 230 MAC Address Direction, 230 MAC Address Mask, 230 Menu, 229 Rule Name, 230 L2 Filtering Rules List, 232 L2 Service, 200 L3/L4 Filtering Rules IP Address, 231 IP Address Direction, 231 IP Address Mask, 231 Menu, 230 Port, 231 Port Direction, 232 Protocol, 231 Rule Name, 231 L3/L4 Filtering Rules List, 232 Last Name, 211 Latitude, 109 LEDs AU-IDU, 52 AU-ODU, 39 AVU, 59 GPS Adapter, 69 298 AU, 161 Management Port Dest Subnet, 134 Dest Subnet Mask, 134 Gateway, 133 IP Address, 133 Management Traffic Enable/Disable, 134 Parameters, 133 Subnet Mask, 133 Management Port Counters, 141 Management Traffic Enable/Disable Data Port, 136 Management Port, 134 Management VLAN (Data Port), 136 Marking Mode 802.1p, 220 DSCP, 220 Transparent, 219 Max Tx Power, 148 Maximum Cell Radius, 162 Maximum Information Rate, 229 Maximum Number of Retries, 116 Maximum Number of Supported Devices SU, 190 Maximum Number of Voice Calls AU, 169 BreezeMAX Modular Base Station System Manual Index Service Profile, Number Of Received Satellites, 222 Minimum Number of Sub-Channels, Minimum Severity, MIR, 169 110 229 ODU Monitor Via Telnet, Add, 91 Via the MON Port, Monitor Password, 148 Delete, 148 ID, 148 Menu, 146 Parameters, 148 Select, 147 Show, 147 Show Summary, 146 Tx Power, 149 Update, 148 164 Multi Channel Parameters, 163 Multicast QoS Profile, 224 Multirate Algorithm, 167 Multirate and ATPC Parameters (SU), Multirate Enable/Disable (AU), 187 168 Multirate Parameters 167 ODU Power Feeder Connectors, 64 63 Installation, Navigation Processor SW Version, LEDs, 109 65 Operation Mode, 53 Non Real Time (NRT) QoS Profile, NPU, 148 Configured ODU Frequency Band, Multi Channel Network Processing Unit, 150 Associated Radio Cluster, 132 127 Show Summary, 148 Admin Status, 90 Monitor Inactivity Timeout, AU, 109 SU, 227 53 BreezeMAX Modular Base Station System Manual 178 Operation Status Bridge Aging Time, 138 Configuration Menu, 132 Connectors, 54 Ejecting, 56 Inserting, 55 LEDs, 54 Menu, 125 Performance Monitoring, 139 Replacing, 60 Reset Unit, 128 Run from Shadow, 130 Set as Main, 130 Set Factory Defaults, 128 Show, 125 SW Versions Control, 128 Unit Control, 127 NRT, 227 Number of Gateways, 173 153 Accounting, 120 Authentication Server, Service, Operator ID, 117 214 104 Optimal Uplink RSSI, 103 Organization Name, 185 Packet Size, 229 Password Defaults (NPU), NPU, 128 127 Performance Service, 214 Performance Monitoring AU, 170 NPU, 139 SU, 196 299 Index Permanent, Profiles 202 Permanent SU Pre-configured, Definition, Protocol (L3/L4 Filtering Rule), 202 Phy (Standard FDD) Parameters SU, PSU, AU, 231 48 Ejecting, 186 56 Inserting, 56 LEDs, 50 Phy Parameters PIU, 237 163 44 LEDs, 47 Replacing, 61 QoS Profile PIU (with HOT SWAP) Best Effort (BE) Service Type, Ejecting, 56 Inserting, 55 CIR, Continuous Grant (CG) Service Type, PIU (without HOT SWAP) 228 Menu, 226 MIR, 229 Name, 228 56 Inserting, 56 Port (L3/L4 Filtering Rule), 231 Port Direction (L3/L4 Filtering Rule), 232 Non Real Time (NRT) Service Type, Ports Counters Power Cable for High-Power (58A) PIU, Power Cable for regular (35A) PIU, QoS Type, 48 47 Power Interface Unit, 44 Power Requirements, 43 Power Supply Unit, 48 PPPoE Service, 200 Pre-configured Profiles, 237 Preferred BST/AU ID, 192 Preferred BST/AU ID Mask, 192 Downlink QoS Profiles, 226 Menu, 224 Name, 225 225 226 Uplink Upper Priority Limits, Priority Classifier Name, 225 219 Priority Marking Value, 221 Priority Type, 225 Priority Marking Mode, 226 Sample Interval, 229 QoS Profile Class, 229 QoS Profile Name, 228 QoS Type, 228 Quick Service Mode, 202 quickynikinyoky, 203 Add, 226 Downlink Upper Priority Limits, Uplink QoS Profiles, Real Time (RT) Service Type, Radio Cluster 199 Priority Type, 229 228 Priority Classifier 300 227 Packet Size, 170 Definition, 227 CT, Ejecting, AU, 227 229 225 144 144 Location, 144 Menu, 143 Name, 144 Parameters, 144 ID, Sector Beam Width, 145 Sector Heading, 145 Select, 144 Show Summary, 143 Radio Parameters (Advanced Si), 192 RADIUS General Parameters, 115 BreezeMAX Modular Base Station System Manual Index RADIUS Parameters, Accounting, 113 Read Community (Authorized Manager), Real Time (RT) Qos Profile, 138 Service 226 Registration Parameters SU, 120 Authentication, 118 Access VLAN, 214 Admin Status, 214 Best Effort, 227 Continuous Grant, 227 Definition, 199 General Parameters, 209 185 Replace AU, 61 59 NPU, 60 PIU, 61 AVU, Generic VoIP (non DRAP-based), Reset Unit Hybrid VLAN Mode, 213 L2, AU, 158 NPU, 128 SU, 181 Retry Interval, 116 RT, 226 200 Menu, 211 Name, 212 Non Real Time, 227 214 Performance, 214 PPPoE, 200 Real Time, 226 SU MAC Address, 212 Types, 200 Operation Status, Run from Shadow AU, 160 NPU, 130 SU, 183 VLAN Classification Mode, Sample Interval, VLAN List, 229 Scanning Intermediate Steps, Scanning Main Step, Sector Heading, Sector ID, 195 Service Mode, 195 199 Maximum Number of Voice Calls, 222 Menu, 216 Name, 217 156 138 Priority Marking Mode, 165 ODU, 147 Radio Cluster, 144 Priority Marking Value, Service Type, VPL ID, 177 217 217 218 Service Profile Class, 222, 226 Service Profile Name, 217 Select by Name 177 Service Profiles Select Server Defining Local Service Profiles, Accounting, 120 Authentication, 118 Send Traps (Authorized Manager), 219 221 VLAN Transparency Mode, Select by MAC Address SU, 210 Definition, 162 Channel, SU, 173 Service Profile 145 Authorized Managers, 213 212 Service Fault Status, Select AU, 202 235 Service Type 138 Server Status BreezeMAX Modular Base Station System Manual L2, 200 PPPoE, 200 301 Index Voice, SU, 201 Services 172 SUs by AU, Defining Local Services, 175 Show Traps Log, 110 Voice (DRAP-based), Signal Processor SW Version, Session Timeout, 236 201 109 Silver LAN-to-LAN Pre-Configured Profile, 203 237 Silver Teleworking Pre-Configured Profile, 237 Smart Card Status, 180 Software Upgrade, 259 Set as Main AU, 160 130 SU, 183 NPU, Speed Set Factory Defaults Data Port, 136 AU, Start Downlink (Rx) Frequency, NPU, Statistics 159 128 SU, 182 Set Rates, 188 Accounting, 121 Authentication, 118 Severity Stop Tx After Hold Over Timeout, Trap Configuration, Shared Secret, Add New SU, 115 Address, Accounting Server, AU Slot #, Show All Accounting Servers, 120 Authentication Servers, 117 Authorized Managers, 138 Show MAC Addresses Behind SU, Show Summary 152 Multi Channel, 164 146 302 185 Bandwidth (Radio Parameters, Advanced Si), 118 Base Station Licenses, 123 Base Station Parameters, 97 CPEs License Bank Status, 122 Files in NPU, 154 General Service Parameters, 209 Grace Licenses, 123 NPU Parameters, 125 ODU, 147 SU #, 177 Temporary Grace Licenses, 123 Show Active Alarms, 110 Radio Cluster, 198 Bandwidth (Phy Standard FDD Parameters), 186 121 156 Authentication Server, ODU, 108 SU 112 Show AU, 195 143 198 193 Base Station ID Parameters), (MAC Standard FDD 186 Base Station ID Mask (MAC Standard FDD Parameters), 186 Bridge Aging Time, 190 Bridging Parameters, 189 Clear All Configured SU SW Files, 198 Configuration Menu, 184 Configured Operation, 173 Configured SW File Name, 173 Configured SW Version, 173 Country, 185 Default SW File (Adv-Si), 176 Default SW File (Std), 176 Delete, 198 Delete SW File, 177 Duplicate SU Name, 174 Ethernet Port, 188 Ethernet Port Auto Negotiation, 189 Ethernet Port Speed and Duplex, 189 IDU Type, 173 BreezeMAX Modular Base Station System Manual Index Installer Password, Loop, Admin Status, 189 173 MAC (Standard FDD) Parameters, Menu, 185 172 Multirate and ATPC Parameters, Number of Gateways, 187 173 Operation Mode, 178 185 Performance Monitoring, 196 Organization Name, Phy (Standard FDD) Parameters, Registration Parameters, Reset Unit, 186 185 211 Definition, 199 Description, 211 First Name, 210 Last Name, 211 Menu, 210 Name, 210 Subscriber Name, 210 SUID, 173 Suppression Interval, 112 SW Download Status AU, 181 Select by MAC Address, 152 SU, 173 177 Select by Name, SW File 177 Service Fault Status, 173 Set Factory Defaults, 182 Set Rates, 188 Show Summary, 172 Status, 181 SW Download Status, 173 SW Files in NPU, 175 SW Versions Control, 182 Unit Control, 181 AU, SU, 160 183 SW Files in NPU AU, 154 SU, 175 SW Versions Control AU, 159 NPU, 128 SU, 182 Uplink (Tx) Frequency (Phy Standard FDD Parameters), User Name, 187 185 Voice/Networking Gateways, Temporary, 188 SU # Temporary Grace Licenses, 123 Temporary SU Menu, 177 Show, 177 Definition, SU Ethernet Port Counters, 202 Termination Action, 203 196 SU MAC Address Service, SU Status, 108 219 Trap Configuration, 111 Admin Status, 111 Severity, 112 196 181 SU SW File Suppression Interval, 161 112 Traps SU Wireless Port Counters, 197 Subnet Mask Data Port, Time Zone Offset From UTC, Transparent Marking Mode, 212 SU Ports Counters, AU, 202 Display Filter, Log, 135 Management Port, 110 110 Traps Display Filter 133 Subscriber BreezeMAX Modular Base Station System Manual Days, 110 Minimum Severity, 110 303 Index Tx Power (ODU), Uplink QoS Profiles, 149 226 Uplink Upper Priority Limits, User Name, UDP Port 185 Accounting Server, 120 Authentication, 118 Unicast Relaying, 223 VLAN Classification Mode, VLAN List, Unit Control 213 212 VLAN Transparency Mode, 217 Voice Parameters (AU), 169 Voice Service, 201 AU, 158 NPU, 127 SU, 181 Voice/Networking Gateways (SU), Unknown Forwarding Policy, 188 237 VoIP 2V Pre-Configured Profile, 237 VPL ID, 218 VoIP 1V Pre-Configured Profile, 224 Update General Service Parameters, ODU, 225 210 148 Uplink (Tx) Frequency SU (Phy Standard FDD Parameters), Uplink Basic Rate (AU), 304 187 Write Community (Authorized Manager), 138 168 BreezeMAX Modular Base Station System Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res Page Mode : UseOutlines XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 6.0 Modify Date : 2008:02:11 07:18:51-08:00 Create Date : 2008:02:04 08:52:34Z Metadata Date : 2008:02:11 07:18:51-08:00 Format : application/pdf Title : BreezeMAX TDD BST System Manual.book Creator : Alvarion Ltd. Document ID : uuid:095ad279-a640-4ecb-ace5-bb3fdce517f5 Instance ID : uuid:a67e9d7c-d8b4-11dc-83a6-00145128619e Page Count : 334 Author : Alvarion Ltd.EXIF Metadata provided by EXIF.tools