AK Series w/K60 Control Owners Manual
WARNING
Electric Shock Hazard - High voltage exists
within this equipment. There are no user
serviceable parts in this equipment. All
installation and service to this equipment
should be performed by qualified licensed
personnel.

Do not exceed 30 minutes in a steambath.
Excessive exposure can be harmful to your
health. Excessive exposure can produce a
rapid pulse, light-headedness, weakness
or fainting. If you become uncomfortable
or experience any of the above conditions
exit the steambath immediately.

AMEREC STEAMBATH GENERATORS
(MODELS: AK5, AK7, AK10 w/K60 CONTROL)

Steambaths can put stress on the body.
Therefore a steambath should be used
only under a doctor's direction if you:
Are pregnant
Have a heart condition
Have high blood pressure
Have circulatory problems
Are under the influence of alcohol
Are under the influence of drugs
Have diabetes
Are under the care of a physician
Are in generally poor health

FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE
WARNINGS TO THE RIGHT AND ALL INSTRUCTIONS BEFORE USING
YOUR STEAMBATH.
POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE STEAMBATH
FOR SAFETY WARNINGS.

Children should only use the steambath
under close adult supervision.
Scald Hazard: Do Not Touch the steam
head or trim during operation as they are
HOT. Stay at least 12 inches away from the
hot steam escaping from the steam head.

Be careful when entering a steambath.
Escaping steam from an overheated steam
room may cause injury.

SAVE THIS MANUAL
Thank you for purchasing your new AMEREC steam generator. If we can be of any assistance
do not hesitate to call our Service Department at 1-800-331-0349.

4209-24 12-09-02

AK Series w/K60 Control Owners Manual

page 2

SECTION 1A: STEAM GENERATOR OVERVIEW
The standard K60 model steam generator control
features an adjustable 60 minute time and temperature control with digital display. The actual
room temperature and time remaining are alternately displayed every 5 seconds. The primary
control can be mounted either inside or outside

the steam room and an optional secondary
control is available to mount in an alternate
location. The temperature can be adjusted in a
range between 100 degrees and 125 degrees
Fahrenheit with an initial default of 120 degrees.
Once the set temperature is reached the ''soft

steam'' feature automatically engages cutting
steam production back to a single element to
provide softer billowing steam during more of
the steam bath. If the steam room temperature
drops more than 5 degrees both elements will
automatically engage.

SECTION 1B: STEAM GENERATOR OVERVIEW - CELSIUS AND 24 HOUR OPTIONS
As an option your K60 control can be ordered
with a Celsius and/or 24 hour timer in place of the
Fahrenheit and 60 minute standard. The Celsius
option's adjustable temperature range is between 38 degrees and 52 degrees Celsius, with

an initial default of 49 degrees. The 24 hour timer
option is adjustable in 1 hour increments from 1
to 24 hours. Other features of the K60 control
should operate as described in section 2 below
with the above noted exceptions.

SECTION 2: OPERATION OF YOUR K60 CONTROL
1. Be sure the power circuit and water supply to
the generator are on.
2. Press the ON/OFF button on the control until
the temperature is displayed.
3. The generator should produce steam in 5 to 10
minutes and will turn off automatically in 60
minutes or less depending on the set time. The
control will alternately display time remaining
and the actual temperature at the sensor in your
steam room every 5 seconds.

4. To change the time setting press and hold the
TIME button on the control. Continuing to hold
the button will cause the time to increase in 5
minute increments from the prior setting. At 60
minutes the time setting will scroll backwards to
5 minutes. To shut down the generator press the
ON/OFF button.

from the prior setting to 125 degrees Fahrenheit.
At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the
lowest setting, 100 degrees Fahrenheit.
6. The TIME and TEMP set points are remembered by the K60 for your next bath unless power
to the steam generator is lost.

5. To change the preset temperature setting
press and hold the TEMP button on the control.
While continuing to hold the button, the temperature display will increase in 1 degree increments

SECTION 3: TAKING A STEAMBATH
1. Wait for the steam room to reach a comfortable temperature.

4. Relax and enjoy the warm steam releasing
tense muscles and refreshing the entire body.

2. Remove clothing and jewelry.

5. If your steam room has a shower a pleasant
experience can be achieved by taking a warm
shower with the steam.

3. Enter the steam room and close the door to
prevent steam from escaping.

SECTION
MAINTENANCE
OF YOUR
STEAMAK
GENERATOR
SECTION4: 4:
MAINTENANCE
OF AK
YOUR
STEAM
The steam generator, steam head, fittings and
plumbing connections should be inspected regularly for water leaks and damage. The AK steam
generator is equipped with a manual drain valve
for flushing sediments from the generator tank.
This procedure should be scheduled monthly or
more often depending on local water conditions
and steam bath usage.

4209-24 12-09-02

6. After a steambath a warm shower will give you
a feeling of relaxation and is conducive to a good
night’s rest. A cold shower will refresh you and
is a good way to start a busy day or prepare you
for an evening out.

GENERATOR

Flushing Procedures:

4. The unit will drain without heating the water.

1. The generator should be cool.

5. Allow the water to run for a full 10 minutes.

2. Press the control ON.

6. Push the control OFF. When the water stops
flowing out the drain, close the manual drain
valve.

3. Open the manual drain valve.

AK Series w/K60 Control Owners Manual

page 3

SECTION 5: TROUBLE SHOOTING GUIDE
The troubleshooting guide is meant as a general aid only. There are no user serviceable parts in the generator. All repairs should be performed by a qualified service
person. For additional assistance or the factory authorized service person nearest you call: AMEREC's Service Department at 1-800-331-0349.
SYMPTOMS
Control won't turn "ON".
(Control lig ht off).

PROBABLE CAUSES
Improper power supplied (no power).
or
Control im properly connected.
or
Control cable is faulty.
or
Contol is faulty.

ACTION TO BE TAKEN
1. a. Make sure circuit breaker is "ON".
b. Using a voltmeter, check the voltage across the two fuses on the "PCA"
printed cir cuit assembly. Voltage should be 208V / 240V.
c. Check fuses, if the fuse(s) are blo wn, replace with Buss#
MDL 15/100 or equivalent fuse. If the fuse blows again - call AMEREC's
Service Department.
2. Check control(s) installed per Section 6-5 in the AK INSTALLATION AND
SERVICE INSTRUCTIONS.
3. Replace control cable - call AMEREC's Service Department.
4. Replace the control - Call AMEREC's Service Department.

Control "OFF".
Unit still makes steam.

Generator is faulty.

1. Turn off the circuit breaker.
2. Call AMEREC's Service Department.

Water runs out of steam head.

Generator is faulty.

1. Turn off the circuit breaker.
2. Turn off the water.
3. Call AMEREC's Service Department.

Steam room too hot or cold .

Temperature adjustment needs setting.

1. See Section 3, "Temperature Adju stment".
2. Call AMEREC's Service Department.

Control "ON".
K60 Control displays "E001".

Temperature sensor not connected.

1. Check that the sensor cable is connected to J4 on the PCA printed circuit
assembly.
2. Check the cable connection to the temperature sensor.
3. Replace sensor and/or cable - call AMEREC's Service Department.

Control "ON".
K60 Control displays "E002".

Temperature sensor.
or
cable shorted.

1. Check sensor cable for damage from nail/staple puncture.
2. Check sensor cable ends for frayed/exposed wire strands.
3. Replace sensor and/or cable - call AMEREC's Service Department.

Control "ON".
K60 Control displays ">>>º".
Control won't turn "OFF".
(Control light on).
Control "ON". (Control light on)
Unit won't steam.

Steambath temperature over 132 º.
or
Sensor/cable is faulty.
Control is faulty.

Unit has not filled completely.
or
Generator is faulty.

1. If bath is too hot, shut off circuit breaker and call AMEREC's Service Department.
2. Treat as "E002" fault above.
1. Replace the control - call AMEREC's Service Department.

1. Wait at least 10 minutes after turning on the control.
2. Call AMEREC's Service Department.

Note: Time/Temp properly.
displayed on K60.
Unable to adjust Time or Temp
setting with K60.
Sudden increases in rate water
sputters out of steam head.

4209-24 12/09/02

Control is faulty.
or
Generator is faulty.
Foaming contamin ants in the water
supply.

1. Replace control - call AMEREC's Service Department.
2. Replace PCA - call AMEREC's Service Department.
1. Flush tank 3 times. See Section 4.

AK Series w/K60 Control Owners Manual

page 4

3

21

33
34
39

44

35

36
15

23

29

28
11

9

16
12

1

43
7

4

13

2
24
17
18
5
22
6
20
8
19

14

P.O. Box 2258, Woodinville WA 98072
425-951-1120 Fax: 425-951-1130
email address: amerec @ amerec .com
4209-24 12-09-02



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 4
Creator                         : X:\DTP\01
Create Date                     : 2003:05:07 10:49:53
Title                           : X:\DTP\01-Amerec\4209-24.PDF
Author                          : lmaninger
Producer                        : Acrobat PDFWriter 4.05 for Windows
EXIF Metadata provided by EXIF.tools

Navigation menu