Amerec Steambath Generator Ak10 Users Manual X
W/K60 K60_OM
AK10 to the manual 5b43705c-463f-4a84-b8f7-49d2d29dae93
2015-02-05
: Amerec Amerec-Steambath-Generator-Ak10-Users-Manual-507622 amerec-steambath-generator-ak10-users-manual-507622 amerec pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
AK Series w/K60 Control Owners Manual WARNING Electric Shock Hazard - High voltage exists within this equipment. There are no user serviceable parts in this equipment. All installation and service to this equipment should be performed by qualified licensed personnel. Do not exceed 30 minutes in a steambath. Excessive exposure can be harmful to your health. Excessive exposure can produce a rapid pulse, light-headedness, weakness or fainting. If you become uncomfortable or experience any of the above conditions exit the steambath immediately. AMEREC STEAMBATH GENERATORS (MODELS: AK5, AK7, AK10 w/K60 CONTROL) Steambaths can put stress on the body. Therefore a steambath should be used only under a doctor's direction if you: Are pregnant Have a heart condition Have high blood pressure Have circulatory problems Are under the influence of alcohol Are under the influence of drugs Have diabetes Are under the care of a physician Are in generally poor health FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE WARNINGS TO THE RIGHT AND ALL INSTRUCTIONS BEFORE USING YOUR STEAMBATH. POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS. Children should only use the steambath under close adult supervision. Scald Hazard: Do Not Touch the steam head or trim during operation as they are HOT. Stay at least 12 inches away from the hot steam escaping from the steam head. Be careful when entering a steambath. Escaping steam from an overheated steam room may cause injury. SAVE THIS MANUAL Thank you for purchasing your new AMEREC steam generator. If we can be of any assistance do not hesitate to call our Service Department at 1-800-331-0349. 4209-24 12-09-02 AK Series w/K60 Control Owners Manual page 2 SECTION 1A: STEAM GENERATOR OVERVIEW The standard K60 model steam generator control features an adjustable 60 minute time and temperature control with digital display. The actual room temperature and time remaining are alternately displayed every 5 seconds. The primary control can be mounted either inside or outside the steam room and an optional secondary control is available to mount in an alternate location. The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees. Once the set temperature is reached the ''soft steam'' feature automatically engages cutting steam production back to a single element to provide softer billowing steam during more of the steam bath. If the steam room temperature drops more than 5 degrees both elements will automatically engage. SECTION 1B: STEAM GENERATOR OVERVIEW - CELSIUS AND 24 HOUR OPTIONS As an option your K60 control can be ordered with a Celsius and/or 24 hour timer in place of the Fahrenheit and 60 minute standard. The Celsius option's adjustable temperature range is between 38 degrees and 52 degrees Celsius, with an initial default of 49 degrees. The 24 hour timer option is adjustable in 1 hour increments from 1 to 24 hours. Other features of the K60 control should operate as described in section 2 below with the above noted exceptions. SECTION 2: OPERATION OF YOUR K60 CONTROL 1. Be sure the power circuit and water supply to the generator are on. 2. Press the ON/OFF button on the control until the temperature is displayed. 3. The generator should produce steam in 5 to 10 minutes and will turn off automatically in 60 minutes or less depending on the set time. The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds. 4. To change the time setting press and hold the TIME button on the control. Continuing to hold the button will cause the time to increase in 5 minute increments from the prior setting. At 60 minutes the time setting will scroll backwards to 5 minutes. To shut down the generator press the ON/OFF button. from the prior setting to 125 degrees Fahrenheit. At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the lowest setting, 100 degrees Fahrenheit. 6. The TIME and TEMP set points are remembered by the K60 for your next bath unless power to the steam generator is lost. 5. To change the preset temperature setting press and hold the TEMP button on the control. While continuing to hold the button, the temperature display will increase in 1 degree increments SECTION 3: TAKING A STEAMBATH 1. Wait for the steam room to reach a comfortable temperature. 4. Relax and enjoy the warm steam releasing tense muscles and refreshing the entire body. 2. Remove clothing and jewelry. 5. If your steam room has a shower a pleasant experience can be achieved by taking a warm shower with the steam. 3. Enter the steam room and close the door to prevent steam from escaping. SECTION MAINTENANCE OF YOUR STEAMAK GENERATOR SECTION4: 4: MAINTENANCE OF AK YOUR STEAM The steam generator, steam head, fittings and plumbing connections should be inspected regularly for water leaks and damage. The AK steam generator is equipped with a manual drain valve for flushing sediments from the generator tank. This procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage. 4209-24 12-09-02 6. After a steambath a warm shower will give you a feeling of relaxation and is conducive to a good night’s rest. A cold shower will refresh you and is a good way to start a busy day or prepare you for an evening out. GENERATOR Flushing Procedures: 4. The unit will drain without heating the water. 1. The generator should be cool. 5. Allow the water to run for a full 10 minutes. 2. Press the control ON. 6. Push the control OFF. When the water stops flowing out the drain, close the manual drain valve. 3. Open the manual drain valve. AK Series w/K60 Control Owners Manual page 3 SECTION 5: TROUBLE SHOOTING GUIDE The troubleshooting guide is meant as a general aid only. There are no user serviceable parts in the generator. All repairs should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call: AMEREC's Service Department at 1-800-331-0349. SYMPTOMS Control won't turn "ON". (Control lig ht off). PROBABLE CAUSES Improper power supplied (no power). or Control im properly connected. or Control cable is faulty. or Contol is faulty. ACTION TO BE TAKEN 1. a. Make sure circuit breaker is "ON". b. Using a voltmeter, check the voltage across the two fuses on the "PCA" printed cir cuit assembly. Voltage should be 208V / 240V. c. Check fuses, if the fuse(s) are blo wn, replace with Buss# MDL 15/100 or equivalent fuse. If the fuse blows again - call AMEREC's Service Department. 2. Check control(s) installed per Section 6-5 in the AK INSTALLATION AND SERVICE INSTRUCTIONS. 3. Replace control cable - call AMEREC's Service Department. 4. Replace the control - Call AMEREC's Service Department. Control "OFF". Unit still makes steam. Generator is faulty. 1. Turn off the circuit breaker. 2. Call AMEREC's Service Department. Water runs out of steam head. Generator is faulty. 1. Turn off the circuit breaker. 2. Turn off the water. 3. Call AMEREC's Service Department. Steam room too hot or cold . Temperature adjustment needs setting. 1. See Section 3, "Temperature Adju stment". 2. Call AMEREC's Service Department. Control "ON". K60 Control displays "E001". Temperature sensor not connected. 1. Check that the sensor cable is connected to J4 on the PCA printed circuit assembly. 2. Check the cable connection to the temperature sensor. 3. Replace sensor and/or cable - call AMEREC's Service Department. Control "ON". K60 Control displays "E002". Temperature sensor. or cable shorted. 1. Check sensor cable for damage from nail/staple puncture. 2. Check sensor cable ends for frayed/exposed wire strands. 3. Replace sensor and/or cable - call AMEREC's Service Department. Control "ON". K60 Control displays ">>>º". Control won't turn "OFF". (Control light on). Control "ON". (Control light on) Unit won't steam. Steambath temperature over 132 º. or Sensor/cable is faulty. Control is faulty. Unit has not filled completely. or Generator is faulty. 1. If bath is too hot, shut off circuit breaker and call AMEREC's Service Department. 2. Treat as "E002" fault above. 1. Replace the control - call AMEREC's Service Department. 1. Wait at least 10 minutes after turning on the control. 2. Call AMEREC's Service Department. Note: Time/Temp properly. displayed on K60. Unable to adjust Time or Temp setting with K60. Sudden increases in rate water sputters out of steam head. 4209-24 12/09/02 Control is faulty. or Generator is faulty. Foaming contamin ants in the water supply. 1. Replace control - call AMEREC's Service Department. 2. Replace PCA - call AMEREC's Service Department. 1. Flush tank 3 times. See Section 4. AK Series w/K60 Control Owners Manual page 4 3 21 33 34 39 44 35 36 15 23 29 28 11 9 16 12 1 43 7 4 13 2 24 17 18 5 22 6 20 8 19 14 P.O. Box 2258, Woodinville WA 98072 425-951-1120 Fax: 425-951-1130 email address: amerec @ amerec .com 4209-24 12-09-02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Creator : X:\DTP\01 Create Date : 2003:05:07 10:49:53 Title : X:\DTP\01-Amerec\4209-24.PDF Author : lmaninger Producer : Acrobat PDFWriter 4.05 for WindowsEXIF Metadata provided by EXIF.tools