GXGF A_レイ A Brochure
Gxgf-A-Brochure 2017 GXGF-A-brochure_2017 GXGF-A-brochure_2017 balances brochures uploads wp-content andweighing 3:
2017-12-12
: And Mercury Gxgf-A-Brochure GXGF-A-brochure balances brochures uploads wp-content
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Multi-Functional Precision Balances GX-A GF-A Series GF-1003A GF-3002A GX-3002A GX-1003A Discover new ways to ensure accuracy, durability and productivity...! ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aandd.jp Introducing The Next Generation Of Automated Weighing Applications Today, it has become commonplace for materials to be weighed with automated devices. As precision balances are increasingly used in that way not just in production lines/systems but also in laboratories, users now face a range of unexpected problems. Fact 1: Precision balances are designed to measure static loads only. The weight sensor of a precision balance, regardless of its manufacturer, breaks in a short period if it is continuously affected by loads with acceleration (i.e. impact shocks). This typically occurs in factories where materials are placed roughly by machines or thrown by operators onto balances. In addition, impact shocks can easily shift values and cause errors. The difficulty is that even if you know the above, you may not know what degree of impact shock is safe or unsafe for the balance to take necessary preventive measures such as refining the automatic loading mechanism. Solution: Impact Shock Detection (ISD) ♦ ♦ Patented The GX-A/GF-A series visualizes the magnitudes of impact shocks that the weight sensor receives at four levels. It beeps once at Level 3 and twice at Level 4 (both of which should be avoided). SHOCK No impact shock SHOCK SHOCK SHOCK SHOCK Level 1 Level 2 Level 3 Level 4 Cushioning under the weighing pan The two leaf springs that support the weighing pan of the GX-A/GF-A series also mitigate impact shocks significantly. Overload protection The weight sensor is well protected against vertical and transverse static overloading. It won't break due to malfunction of the weighing system's actuator and the resulting excess load. A&D's testing demonstrated that even a human did no damage to the balance by stepping on it. Leaf springs Fact 2: Precision balances are intended to be used in a stable environment. The performance (repeatability as well as display stability) of a precision balance is worsened by external disturbances such as drafts and vibrations, which is often the case in the field. Therefore, it is strongly recommended to evaluate whether the set-up conditions are appropriate. Checking repeatability, however, is cumbersome, especially once the balance is embedded in a system. Further, it is not uncommon that users don't have an adequate test weight. 1 Solution: Auto Precision Assessment (APA) The GX-A/GF-A series is designed with A&D's latest technology, Electronically Controlled Load (ECL). This technology artificially generates a minute load (0.3 to 3% of the weighing capacity) by altering the equilibrium state of the weight sensor. ♦ After making a quick diagnosis of whether there is a critical failure, the balance indicates the standard deviation (i.e. repeatability) calculated from 10 repeated measurement with ECL on the spot. The entire process takes only 1.5 minutes. ♦ Patent pending Standard deviation calculated using ECL Adjustable response characteristics You can trade weighing speed for higher display stability*1 or vice versa by selecting one of three preset response characteristics (FAST, MID or SLOW). *1 This is not to improve repeatability. Fact 3: Internal clocks of precision balances are never in complete sync with those of external devices. This clock time disparity manifests as a problem most noticeably when you measure and record flow rates of pumps, feeders and other devices at short intervals*2 with a balance connected to a PC that performs the calculation. The timing at which the balance receives the command from the PC to send the weight value and its display refresh cycle gradually go out of alignment. In consequence, the PC intermittently produces irregular values (spikes when graphed) even if the actual flow rate is constant. *2 Flow rate is determined from the weight variation that occurs during a given interval. 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec Balance 0 1 2 3 4 5 1 1 sec PC 2 3 4 5 1 2 sec 2 3 4 5 1 3 sec 2 3 4 5 1 4 sec 2 3 4 5 1 2 5 sec 3 4 5 6 6 sec Time disparity of two different internal clocks (when the balance display refresh rate is 5 times/sec, the interval is 1 sec, and the balance's internal clock goes slightly ahead of the PC's) Solution: Flow Rate Display (FRD) The GX-A/GF-A series can calculate and display/output the mass flow rate (the unit of measure can be selected from g/s, g/m or g/h), or the volume flow rate (mL/s, mL/m or mL/h) by entering the density of the material. Up to 10 densities can be saved to the device. Both the display refresh rate and interval (set between 1 second and 1 hour) are regulated by the same internal clock of the balance, making measurements free from the aforementioned problem. 0.45 g/s Conventional method FRD 0.4 g/s 0.35 g/s Flow rate measurement using FRD as opposed to the conventional method 2 Flow rate comparator The indication allows you to monitor whether the flow rate is kept within the designated limits. Tare memory The tare value can be saved in non-volatile memory so that the remaining amount of the material in the container can be displayed again*3, even if power is disrupted for any reason during loss-in-weight measurement. *3 When this function is activated, the power-on re-zero/tare is turned off. On top of the above, the GX-A/GF-A series has many advanced and practical features and is perfect for manual weighing applications. RS-232C and USB interfaces as standard For the USB interface, you can toggle between the Quick USB mode (plug-and-play with weighing data output to a PC only) and the Virtual COM mode (for bi-directional communication*4) with internal settings. A USB cable is provided as standard. Security slot An off-the-shelf (such as Kensington) anti-theft lock can be used to prevent the balance from being lost. driver downloaded from the A&D website needs * 4 toA bespecial installed on the PC (except those with Windows 10). Reverse backlit LCD display The contrast of black and white provides excellent visibility even in poorly-lit areas and also prevents eye fatigue. Large, easy-to-see spirit level with LED illumination The illumination blinks for 5 seconds after the display is turned on to indicate that the balance level needs to be checked. 3 Leveling feet with thumbwheel The leveling feet can be adjusted up or down smoothly using large thumbwheels. Data management, documentation and compliance Minimum weight calculation based on the APA From the standard deviation obtained using ECL described earlier, the GX-A/GF-A series also calculates and indicates the minimum weight at the installation location*5 in accordance with the United States Pharmacopeia (USP) standard. effects of the ambient environmental conditions on repeatability is taken *5 The into account, unlike the values shown in catalogs as "ideal" or "typical". Minimum weight alert To ensure that the measured sample quantity meets the minimum weight requirement, the GX-A/GF-A series can display an alert until the sample quantity reaches the value entered as the minimum weight.* 6 is also possible to directly use the minimum *6 Itweight determined by ECL. Blinking minimum weight alert User access control (UAC) and key lock for data integrity Use of the balance can be password-protected for authorized individuals (up to 11 including one administrator)—the administrator can perform all operations including calibration while other users can make measurements only. Moreover, upon receiving a command to disable its keys, the balance becomes operable only by sending commands from an external device such as a PC. Automatic self calibration (for the GX-A series) The GX-A series can be set to calibrate itself automatically using its internal weight either (1) in response to change in ambient temperature (approx. 10 ˚C) to prevent error due to sensitivity drift, (2) at a set interval time, or (3) at predetermined (up to three) times of the day. Internal calibration can also be performed any time with one key press. GLP/GMP/GCP/ISO compliant output For documentation requirements, the GX-A/GF-A series can output its manufacturer, model, serial number, ID number, date + time, space for signature for calibration report, calibration test report, and title & end blocks for a series of weighing results. Universal Flexi Coms (UFC) UFC lets you edit serial data output/printout format. With this function, label printing is also made possible by connecting the balance to a commercially-available printer*7, and enabling arbitrary character strings output. that can program printing content from the strings sent through RS-232C. *7 Printers Please note that a cross cable is required depending on the printer. Gross/Net/Tare output On receiving a command or with key operation, the GX-A/GF-A series outputs the gross, net, and tare values to an external device such as a printer, PC or PLC. Statistical calculation function (SCF) The GX-A/GF-A series can display and output statistical calculation data including number of data, sum, maximum, minimum, range (maximum-minimum), average, standard deviation, and coefficient of variation to facilitate the analysis of measurements. 4 Options | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2nd RS-232C interface*8 Comparator relay output/buzzer/external key input interface*8 GXA-03 GXA-04 Enables signaling check weighing results (5 steps) by buzzer and/or external comparator (traffic) lights. It also has two jacks for separately-sold foot switches. Analog output interface*8 GXA-06 0-1 V, or 0.2-1 V for conversion to 4-20 mA. Ethernet interface*8 Built-in rechargeable battery (factory-installed/dealer option) *8 FXi-08 GXA-09 10 hours of charging for 14 hours of operation (the remaining battery level will be indicated on the display). The balance can be used while recharging the battery. Large glass breeze break Animal weighing pan (for models of 320 g capacity or higher) GXA-10 GXA-12 Use together with the animal weighing (average & hold) mode. Density determination kit (for the 1 mg models only) GXA-13 Makes weighing the sample in air and in water quicker, easier and more precise. The GX-A/GF-A series can then perform a density calculation automatically. Large glass breeze break with built-in fanless ionizer (static eliminator) GXA-17 The fanless ionizer can neutralize even extremely fine powders without disturbance. GXA-10 Large glass breeze break External key input interface with the The glass panes disappear into the back when opening 8 AX-SW137-PRINT foot switch* the door, requiring no extra space at the rear of the GXA-23-REZERO External key input interface with the balance. Easily attachable/detachable. AX-SW137-REZERO foot switch*8 External key input interface with the AX-T-314A-S plug*8 GXA-23-PLUG USB host interface (factory-installed/dealer option) *8 GXA-24 GXA-23-PRINT Accepts an off-the-shelf USB flash drive to save weighing results in CSV format. GXA-25 External fanless ionizer (static eliminator) *8 Power is supplied from the balance. Activated for a set duration with an IR sensor. GXA-26 External IR switch*8 For touchless operation of print or re-zero (tare). one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, *8 Only GXA-24, GXA-25 or GXA-26 can be installed. Accessories | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | AD-1641 AD-1682 AD-1683 AD-1684A AD-1687 AD-1688 AD-1689 AD-1691 AD-8127 AD-8526 AD-8920A AD-8922A AX-GXA-31 AX-SW137-PRINT AX-SW137-REZERO AX-USB-9P Air flow logger Rechargeable battery unit Static eliminator*9 Electrostatic field meter Weighing environment logger Weighing data logger Tweezers for calibration weight Weighing environment analyzer Compact printer Serial/Ethernet converter Remote display Remote controller Main unit cover (5 pcs) Foot switch for print Foot switch for re-zero Serial/USB converter *9 Power needs to be supplied from an AC adapter. 5 AD-8127 AX-SW137-PRINT AX-SW137-REZERO AD-8529PC/PR-W Bluetooth converters Enable wireless communication between a balance/scale and a PC/printer using low-energy Bluetooth*10 (line-of-sight distance approx. 10 m when there is no radio wave interference). AD-8529PC-W for communication with a PC USB connector Approx. 10 m D-Sub connector AD-8529PR-W for communication with a printer contact your local A&D representative to find out whether the AD-8529PC/PR-W *10 isPlease certified for compliance with Bluetooth communication laws in your country. Dimensions (mm/inches) D-Sub connector 317/12.48 40/1.58 160/6.3 144/5.67 124/4.88 212/8.35 160/6.3 144/5.67 124/4.88 74.5/2.93 77/3.03 GF-123A / GF-203A / GF-303A / GF-403A / GF-603A / GF-1003A / GF-1603A 210/8.27 GX-203A / GX-303A / GX-403A / GX-603A / GX-1003A / GX-1603A 190/7.48 175/6.7 128/5.04 90/3.54 93/3.66 128/5.04 94.7/3.73 181/7.13 217/8.54 224/8.82 317/12.48 GX-2002A / GX-3002A / GX-4002A / GX-6002A / GX-10002A 210/8.27 212/8.35 GF-1202A / GF-2002A / GF-3002A / GF-4002A / GF-6002A / GF-10002A 40/1.58 165/6.5 190/7.48 93/3.66 165/6.5 181/7.13 94.7/3.73 217/8.54 224/8.82 6 Specifications Models Weighing capacity Minimum weighing value Repeatability (standard deviation) GX-203A GX-303A GX-403A GX-603A GX-1003A GX-1603A GF-123A GF-203A GF-303A GF-403A GF-603A GF-1003A GF-1603A 120 g 220 g 320 g 420 g 0.001 g 620 g 1100 g 1620 g 0.002 g (for 1600 g) 0.001 g (for 1000 g) 0.001 g Linearity Stabilization time (when set to FAST under a good environment) ±0.002 g ±0.003 g Approx. 1.5 sec (approx. 0.8 sec for 5 g) Approx. 1 sec (approx. 0.8 sec for 5 g) Sensitivity drift Accuracy immediately after internal calibration (for the GX-A series) i ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF) ±0.010 g (for 1000 g) ±0.010 g Operating environment Display refresh rate Units of measure ii 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation) 5 times/sec, 10 times/sec or 20 times/sec g (gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (specific gravity), and a user-programmable unit. Counting mode Minimum unit mass Number of samples Percent mode Minimum 100% reference mass Minimum 100% display Communication interface Applicable calibration weight value 0.001 g 5, 10, 25, 50 or 100 pieces 0.100 g 0.01%, 0.1% or 1% (depends on the reference mass stored) RS-232C and USB 50 g 50 g 50 g 50 g 50 g 100 g 100 g 100 g 100 g 100 g (100 g interval) (100 g interval) (100 g interval) 200 g 200 g 300 g 400 g 600 g 1000 g 50 g 100 g Weighing pan size External dimensions Net weight Power supply / consumption 50 g 100 g (100 g interval) 1600 g 128 × 128 mm 212(W) × 317(D) × 93(H) mm Approx. 5 kg AC adapter / approx. 30 VA GX-2002A GX-3002A GX-4002A GX-6002A GX-10002A GX-6001A GX-10001A GF-1202A GF-2002A GF-3002A GF-4002A GF-6002A GF-10002A GF-6001A GF-10001A Models Weighing capacity Minimum weighing value Repeatability (standard deviation) 1200 g 2200 g 4200 g 3200 g 6200 g 10200 g 0.1 g 0.02 g (for 10000 g) 0.01 g (for 5000 g) 0.01 g Linearity Stabilization time (when set to FAST under a good environment) ±0.02 g 0.1 g ±0.03 g ±0.1 g Approx. 1.5 sec Approx. 1 sec (approx. 0.8 sec for 50 g) (approx. 0.8 sec for 500 g) Approx. 1 sec (approx. 0.8 sec for 50 g) Sensitivity drift Accuracy immediately after internal calibration (for the GX-A series) i 10200 g 6200 g 0.01 g ±2 ppm/°C (10 to 30 °C/50 to 86 °F, when automatic self-calibration is OFF) ±0.10 g Operating environment Display refresh rate Units of measure ii ±0.15 g ±0.15 g (for 5000 g) ±0.5 g (for 5000 g) 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation) 5 times/sec, 10 times/sec or 20 times/sec g (gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (specific gravity), and a user-programmable unit. Counting mode Minimum unit mass Number of samples Percent mode Minimum 100% reference mass Minimum 100% display Communication interface Applicable calibration weight value 0.01 g 5, 10, 25, 50 or 100 pieces 500 g 1000 g 500 g 1000 g 2000 g 0.1 g 1.00 g 10.0 g 0.01%, 0.1% or 1% (depends on the reference mass stored) RS-232C and USB 500 g 500 g 500 g 500 g 500 g 500 g 1000 g 1000 g 1000 g 1000 g 1000 g 1000 g (1000 g interval) (1000 g interval) (1000 g interval) (1000 g interval) (1000 g interval) 2000 g 3000 g 4000 g 6000 g 10000 g 6000 g 10000 g Weighing pan size External dimensions Net weight Power supply / consumption 165 × 165 mm 212(W) × 317(D) × 93(H) mm Approx. 5 kg AC adapter / approx. 30 VA i Under stable environment (no rapid temperature/humidity change, vibration, draft, magnetism, static, etc). The mass of the internal weight may vary with age. ii One additional unit from tael (Singapore/HK jewelry/Taiwan/China), tola or Newton can be added upon request. 12 9 3 6 GX-A GF-A Impact Shock Detection Flow Rate Display Electronically Controlled Load Quick USB USB Interface User Access Control Clock & Calendar ON Comparator Function Auto Power ON Universal Flexi Coms Optional USB Host Interface ...Clearly a Better Value 3-23-14 Higashi-lkebukuro, Toshima-ku,Tokyo 170-0013 JAPAN Telephone:[81](3) 5391-6132 Fax:[81](3) 5391-1566 http://www.aandd.jp 1756 Automation Parkway, San Jose, CA 95131 U.S.A. Telephone:[1](408) 263-5333 Fax:[1](408) 263-0119 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone:[61](8) 8301-8100 Fax:[61](8) 8352-7409 Unit 24/26 Blacklands Way Abingdon Business Park, Abingdon, Oxon OX14 1DY UNITED KINGDOM Telephone:[44](1235) 550420 Fax:[44](1235) 550485Hamburger Straße 30 D-22926 Ahrensburg GERMANY Telephone:[49](0) 4102 459230 Fax:[49](0) 4102 459231 Vereyskaya str.17, Moscow, 121357 RUSSIA Telephone: [7] (495) 937-33-44 Fax: [7] (495) 937-55-66 A&D Instruments India Private Limited 509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, INDIA Telephone: [91](124) 471-5555 Fax: [91](124) 471-5599 817, Manhattan Bldg., 33, Gukjegeumyung-ro 6-gil, Yeongdeungpo-gu, Seoul, 07331, KOREA Telephone:[82](2) 780-4101 Fax:[82](2) 782-4280 * GXGF-A-ADCC-01-PR1-17c01GP
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2017:11:28 19:26:42+09:00 Creator : Adobe Illustrator CS6 (Macintosh) Modify Date : 2017:11:29 19:43:35+09:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Title : GXGF-A_レイ Metadata Date : 2017:11:29 19:43:35+09:00 Creator Tool : Adobe Illustrator CS6 (Macintosh) Thumbnail Width : 256 Thumbnail Height : 56 Thumbnail Format : JPEG Thumbnail Image : (Binary data 7652 bytes, use -b option to extract) Instance ID : uuid:2e4ae040-5a2d-964e-84e4-76d6df13d506 Document ID : xmp.did:0980117407206811822AAE7385E1FD8C Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : uuid:7d6a93bf-1a33-b04c-8444-323208a7550d Derived From Document ID : xmp.did:0580117407206811822A9FF602E0A126 Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : default History Action : saved, saved History Instance ID : xmp.iid:0580117407206811822A9FF602E0A126, xmp.iid:0980117407206811822AAE7385E1FD8C History When : 2017:10:18 17:37:57+09:00, 2017:11:28 19:26:36+09:00 History Software Agent : Adobe Illustrator CS6 (Macintosh), Adobe Illustrator CS6 (Macintosh) History Changed : /, / Startup Profile : Print Has Visible Overprint : False Has Visible Transparency : True N Pages : 1 Max Page Size W : 210.001652 Max Page Size H : 296.999959 Max Page Size Unit : Millimeters Font Name : AvantGarde-Demi, HelveticaNeue-Roman, StoneInformal, StoneInformal-Italic, StoneInformal-Semibold, StoneInformal-Bold, Times-Roman, Times-Bold, TimesNewRomanPSMT, HiraginoSans-W3 Font Family : ITC Avant Garde Gothic, Helvetica Neue, ITC Stone Informal, ITC Stone Informal, ITC Stone Informal, ITC Stone Informal, Times, Times, Times New Roman, ヒラギノ角ゴシック Font Face : Demi, 55 Roman, Medium, Italic, Semibold, Bold, Regular, Bold, Regular, W3 Font Type : Type 1, Type 1, Type 1, Type 1, Type 1, Type 1, TrueType, TrueType, Open Type, Open Type Font Version : 001.007, 001.102, 001.000, 001.000, 001.000, 001.000, 10.0d1e3, 10.0d1e3, Version 5.05, 11.0d7e4 Font Composite : False, False, False, False, False, False, False, False, False, False Font File Name : AvantGarDem; ITC Avant Garde Gothic 1, HelveNeuRom; Helvetica Neue, StoneInf; ITC Stone Informal, StoneInfIta; ITC Stone Informal, StoneInfSem; ITC Stone Informal, StoneInfBol; ITC Stone Informal, Times.dfont, Times.dfont, Times New Roman.ttf, ヒラギノ角ゴシック W3.ttc Plate Names : Cyan, Magenta, Yellow, Black Swatch Group Name : 初期設定のスウォッチグループ Swatch Group Type : 0 Swatch Colorant Swatch Name : C=0 M=50 Y=100 K=0, C=50 M=0 Y=100 K=0, HV, GX, GF-1, GF-A, GX-A, GXF-A, 新規カラースウォッチ 3, C=40 M=25 Y=0 K=0, 深海ブルー (グローバル), GX-A_2 Swatch Colorant Mode : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK Swatch Colorant Type : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS Swatch Colorant Cyan : 0.000000, 50.000000, 100.000000, 80.000000, 80.000000, 65.000000, 70.000000, 100.000000, 0.000000, 40.000000, 100.000000, 80.000000 Swatch Colorant Magenta : 50.000000, 0.000000, 80.000000, 30.000002, 30.000002, 40.000000, 50.000000, 80.000000, 100.000000, 25.000000, 100.000000, 57.142902 Swatch Colorant Yellow : 100.000000, 100.000000, 20.000000, 0.000000, 80.000000, 55.000000, 20.000000, 30.000002, 50.000000, 0.000000, 0.000000, 22.857100 Swatch Colorant Black : 0.000000, 0.000000, 0.000000, 20.000000, 0.000000, 0.000000, 0.000000, 0.000000, 30.000002, 0.000000, 0.000000, 0.000000 Swatch Colorant Tint : 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000 Producer : Adobe PDF library 10.01 Page Count : 8EXIF Metadata provided by EXIF.tools