Andante Medical Devices SMARTSTEP0106 Bluetooth Transmitter User Manual 1

Andante Medical Devices Ltd. Bluetooth Transmitter 1

Contents

User Manual 1

 SmartStep™ Clinic User’s Manual        Andante Medical Devices Ltd © Andante Medical Devices Ltd http://www.andante.co.il
Legal Notice  2  |  SmartStep™ Version 2.1.1 Revision A2  Legal Notice This manual contains information that is proprietary to Andante Medical Devices Ltd. (“Andante”). No part of this publication may be reproduced in any form without prior written approval by Andante. Right,  title  and  interest,  all  information, copyrights,  patents,  know-how,  trade  secrets  and  other intellectual property or other proprietary rights relating to this manual and to the SmartStep™ System (“the Product”), and any software components contained therein, are proprietary products of Andante protected under international copyright and patent law and shall be and remain solely with Andante. SmartStep™ is a trademark of Andante. No right, license, or interest to such trademark is granted hereunder. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the Product. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the Product, based on or derived in any way from the Product.  All brand and product names mentioned in this manual are trademarks and/or registered trademarks of their respective holders.
    About this Document  SmartStep™ Version 2.1.1 Revision A2  |  3  About this Document This document describes the SmartStep™ insole, Control Unit, and software, used for the assessment and training of walking pathologies. The document is intended for therapists treating patients with walking pathologies. Chapters and Contents  1 Introduction  SmartStep™ functions and usage.  Pg. 18  2  System Description   SmartStep™ kit contents and system components.  Pg. 19 3 Installation  How to install the SmartStep™ software.  Pg. 24 4 Preparing a Session  How to prepare patient, hardware components and SmartStep™ software for a session. Pg. 48 5  Starting a Session  How to begin a session, connect to the Bluetooth USB adapter, and perform calibration. Pg. 53 6 Online Work  How to define an online session.  Pg. 62 7 Offline Work  How to define an offline session and download data to the computer.   Pg. 68 8 Tracking the Rehabilitation Progress How to open saved sessions, understand and compare session statistics, and manipulate session charts. Pg. 73 9  Turning the Control Unit Off How to turn the Control Unit off.  Pg. 89 10 Maintenance and Administration How to create users, change passwords, recharge batteries, change insoles, and keep SmartStep™ clean. Pg. 90 11 Troubleshooting  How to deal with various operating problems.  Pg. 93  Style Conventions  Convention Used for Verdana  Regular text. Arial Bold  Names of menus, commands, buttons, and other elements of the user interface. Arial Italics  Special terms, the first time they appear. Monospace  Text entered by a user, values of parameters, and usage examples.  Notes, which offer an additional explanation or a hint on how to overcome a common problem.
About this Document  4  |  SmartStep™ Version 2.1.1 Revision A2  Warnings, which indicate potentially damaging user operations and explain how to avoid them.
    Table of Contents  SmartStep™ Version 2.1.1 Revision A2  |  5  Table of Contents LEGAL NOTICE...........................................................................................2 ABOUT THIS DOCUMENT............................................................................3 TABLE OF CONTENTS .................................................................................5 INTENDED USE..........................................................................................8     TECHNICAL SPECIFICATION ……………………………………………………………... 9 WARNINGS, PRECAUTIONS AND LIMITATIONS........................................11 LIMITATIONS .......................................................................................... 11 WARNING AND PRECAUTIONS ....................................................................... 12 CLASSIFICATION.....................................................................................15 REGULATORY COMPLIANCE .....................................................................16 CARE AND MAINTENANCE........................................................................17 1 INTRODUCTION.................................................................................18 1.1 OBJECTIVE ASSESSMENT ..................................................................... 18 1.2 TRAINING ...................................................................................... 18 1.3 REHABILITATION TRACKING.................................................................. 18 1.4 USING SMARTSTEP™ IN ONLINE AND OFFLINE MODE.................................... 18 2 SYSTEM DESCRIPTION.......................................................................19 2.1 SMARTSTEP™ KIT CONTENTS ............................................................... 19 2.2 SMARTSTEP™ COMPONENTS ................................................................ 20 2.2.1 Insole................................................................................ 20 2.2.2 Control Unit........................................................................ 21 2.2.3 SmartStep™ Software.......................................................... 23 2.2.4 Manual Pump...................................................................... 23 3 INSTALLATION ..................................................................................24 3.1 SYSTEM REQUIREMENTS...................................................................... 24 3.2 SMARTSTEP SOFTWARE INSTALLATION..................................................... 24 3.3 BLUETOOTH USB ADAPTER DRIVER INSTALLATION....................................... 28 3.4 CONFIGURE SMARTSTEP™ FOR BLUETOOTH USAGE ...................................... 46 4 PREPARING A SESSION ........................ERROR! BOOKMARK NOT DEFINED. 4.1 CHECK AIR PRESSURE - INFLATE THE INSOLE IF NECESSARY.ERROR! BOOKMARK NOT
Table of Contents  6  |  SmartStep™ Version 2.1.1 Revision A2 DEFINED. 4.2 REMOVE THE PATIENT’S SHOE .......................ERROR! BOOKMARK NOT DEFINED. 4.3 INSERT THE INFLATED INSOLE INTO THE SHOE.....ERROR! BOOKMARK NOT DEFINED. 4.4 PUT THE PATIENT’S SHOE BACK ON..................ERROR! BOOKMARK NOT DEFINED. 4.5 ATTACH THE CONTROL UNIT TO THE ANKLE........ERROR! BOOKMARK NOT DEFINED. 4.6 CONNECT THE INSOLE TO THE CONTROL UNIT.....ERROR! BOOKMARK NOT DEFINED. 4.7 INSERTING THE BLUETOOTH USB ADAPTER .......ERROR! BOOKMARK NOT DEFINED. 4.8 TURN ON THE CONTROL UNIT .......................ERROR! BOOKMARK NOT DEFINED. 4.9 LAUNCHING THE SMARTSTEP™ SOFTWARE ........ERROR! BOOKMARK NOT DEFINED. 5 STARTING A SESSION........................... ERROR! BOOKMARK NOT DEFINED. 5.1 PATIENT FILE ..........................................ERROR! BOOKMARK NOT DEFINED. 5.1.1 Creating a New Patient File.......... Error! Bookmark not defined. 5.1.2 Opening an Existing Patient File ... Error! Bookmark not defined. 5.2 STARTING A SESSION ................................ERROR! BOOKMARK NOT DEFINED. 5.3 CONNECTING TO THE BLUETOOTH USB ADAPTER.ERROR! BOOKMARK NOT DEFINED. 5.4 PERFORMING CALIBRATION ..........................ERROR! BOOKMARK NOT DEFINED. 6 ONLINE WORK...................................... ERROR! BOOKMARK NOT DEFINED. 6.1 DEFINING WORKOUT PLAN AND OPERATION MODEERROR! BOOKMARK NOT DEFINED. 6.2 PERFORMING THE WORKOUT.........................ERROR! BOOKMARK NOT DEFINED. 7 OFFLINE WORK..................................... ERROR! BOOKMARK NOT DEFINED. 7.1 DEFINING WORKOUT PLAN AND OPERATION MODEERROR! BOOKMARK NOT DEFINED. 7.2 PERFORMING THE WORKOUT.........................ERROR! BOOKMARK NOT DEFINED. 7.3 DOWNLOADING DATA TO THE COMPUTER ..........ERROR! BOOKMARK NOT DEFINED. 8 TRACKING THE REHABILITATION PROGRESS...... ERROR! BOOKMARK NOT DEFINED. 8.1 OPENING PREVIOUSLY RECORDED SESSIONS......ERROR! BOOKMARK NOT DEFINED. 8.2 UNDERSTANDING SESSION RESULTS ...............ERROR! BOOKMARK NOT DEFINED. 8.2.1 Switching Between Absolute and Relative WeightError! Bookmark not defined. 8.2.2 Charts ...................................... Error! Bookmark not defined. 8.2.3 Statistics................................... Error! Bookmark not defined. 8.2.4 Viewing Stance/Swing Composition for Specific Steps..........Error! Bookmark not defined. 8.2.5 Comments ................................ Error! Bookmark not defined. 8.3 MANIPULATING SESSION CHARTS...................ERROR! BOOKMARK NOT DEFINED.
    Table of Contents  SmartStep™ Version 2.1.1 Revision A2  |  7  8.3.1 Zooming In and Out ...................Error! Bookmark not defined. 8.3.2 Measuring Time .........................Error! Bookmark not defined. 8.3.3 Measuring  Weight......................Error! Bookmark not defined. 8.3.4 Erasing Session Segments...........Error! Bookmark not defined. 8.4 COMPARISON STATISTICS............................ERROR! BOOKMARK NOT DEFINED. 8.5 SESSION DELETION...................................ERROR! BOOKMARK NOT DEFINED. 9 TURNING THE CONTROL UNIT OFF........ERROR! BOOKMARK NOT DEFINED. 10 MAINTENANCE AND ADMINISTRATION.ERROR! BOOKMARK NOT DEFINED. 10.1 CREATING USERS AND CHANGING PASSWORDS...ERROR! BOOKMARK NOT DEFINED. 10.2 RECHARGING BATTERIES.............................ERROR! BOOKMARK NOT DEFINED. 11 TROUBLESHOOTING..............................ERROR! BOOKMARK NOT DEFINED. PARTS AND ACCESSORIES ..........................ERROR! BOOKMARK NOT DEFINED.
Table of Contents  8  |  SmartStep™ Version 2.1.1 Revision A2 Intended Use  SmartStep™ is intended to measure the weight applied to the plantar surface of the affected limb during rehabilitation. The device alerts the patient and/or therapist with a beeping sound when the weight exceeds a pre-determined maximum level. SmartStep™ produces objective examination, training and monitoring of gait outcomes, using accurate analysis as well as audio and visual feedback.
    Table of Contents  SmartStep™ Version 2.1.1 Revision A2  |  9  Technical Specifications Control Unit  General  Dimensions  110 x 68 x 48 mm    Weight 215 g    Operating Time  Approx. 5 Hours (Full battery, max load)    Charging Time  Approx. 10 Hours (Empty battery)  Battery Operating Voltage  3.6 VDC    Type Ni-MH Rechargeable battery    Capacity 700 mAh    Power Consumption  0.5 W  Indicators Mode of Operation  7 Segment    Charging Green LED    Low Battery  Orange LED  Memory Capacity 128 KB    Type   Rewritable    Max record time  Approx. 10 Minutes    No. of Logged files  1  Connectors Input Type  RJ-11    Input Uses  Charging   Communication Type Wireless    Protocol  Bluetooth ver. 1.1 certified    Transmission frequency  2.4 GHz    Output Power  0 dBm (Class 2)    Maximum distance  10 m / 30 ft  Environmental Conditions Operating Temperature  10 ºC to 40 ºC    Storage Temperature  -5 ºC to 50 ºC    Operating Humidity  30% - 75%
Table of Contents  10  |  SmartStep™ Version 2.1.1 Revision A2  Charger General  Manufacturer GlobTek Inc.    Model GT-A81051-0509UW2    Dimensions  54.0 x 40.0 x 29.5 mm    Weight 90 g    Input Voltage  90 Vac to 264 Vac    Output Voltage  9 VDC    Max. Output Power 5 W    Standard  UL 60950, CUL, CLASS II FCC Part 15 CLASS B  Sensors General  Type Silicon Pressure Sensor    Compensation  Temperature Compensated Over –40° to +125°C  Operating Characteristics Pressure Range  0 – 250 kPa    Supply Voltage  5 VDC    Supply Current  7 mA    Sensitivity 18 mV/kPa
    Table of Contents  SmartStep™ Version 2.1.1 Revision A2  |  11    Warnings, Precautions and Limitations  Please read, understand, and follow the precautionary and operating instructions:  Limitations  SmartStep™ is a biofeedback device and does not prevent injury. Therefore if the patient feels any pain or discomfort while using the device he should stop using the device immediately and consult a physician.  Andante Medical Devices Ltd is NOT responsible for any damages that occur as a result of the misuse of this device.  Physician or therapist must check very high arches in their patients. In cases of a high arch, system accuracy will be reduced.   SmartStep™ should only be used in accordance with the exercise options provided in the software and should not be used while running, jumping, etc.  Weight limits should be set by qualified personal and not by the patient.  A patient with hearing loss, particularly in the higher frequencies should not use this device as he may not be able to hear the audio feedback tone.   SmartStep™ is designed for use with sports shoes only. Do not use with other types of shoes.  Patients must wear socks during sessions. SmartStep™ should not be used by barefoot patients.  SmartStep™ should not be used in cases of: o Non-weight bearing prescription. o Activity limitations due to medical disorder, medication, or emotional conditions. o Vascular insufficiencies or infection.  o Severe cognitive disabilities.
Table of Contents  12  |  SmartStep™ Version 2.1.1 Revision A2 Warning and Precautions Control Unit    Never try to connect any other device and/or cable to the Charging connector of the Control Unit (e.g. telephone device or cables).   The plastic cover used to seal the Charging  connector should never be removed while the unit is on the patient’s leg. The cover should only be removed when charging the unit.     When charging the Control Unit, the unit and its strap must be removed from the patient’s leg.    This equipment has been approved for mobile applications where the equipment should be used at distances greater than 20cm from the human body (with the exception of hands, wrists, feet and ankles). Operation at distances less than 20cm is strictly prohibited.  Protect the Control Unit from any contact with water, such as dampness from sinks, bathtubs and shower stalls, or wet weather such as rain or snow. Do not use water or any other liquids to clean the Control Unit.  Shock or impact may damage the Control Unit.  The Control Unit should be operated, transported, and stored within a temperature range of 10-40°C, (50-86°F) and a relative humidity of 30-75%.  Do not open the Control Unit case. Only an Andante Medical Devices technician is authorized to disassemble the device. Important Charging Information    Only use the charger provided with your SmartStep™ system. Do not substitute with any other charger. Use of another charger could cause batteries to explode and possible serious injury.
    Table of Contents  SmartStep™ Version 2.1.1 Revision A2  |  13    Charging must be done outside the patient environment and should be obtain in the medical used room.                              Do not operate the charger with a damaged cord or plug. If damaged, have the charger replaced immediately by a qualified service technician. Following this rule will reduce the risk of electric shock, fire, or serious personal injury.  Do not disassemble the charger. Only an Andante Medical Devices technician is authorized to take the device a part.  Do not use the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way. Consult an Andante service technician to replace the charger. Following this rule will reduce the risk of electric shock, fire, or serious personal injury.  When the charger is not in use, disconnect it from the power source. Do not leave the battery connected to charger for longer than a week, since overcharging may shorten its lifespan. If left unused, a fully charged battery will discharge itself over time. Important Battery Information    There is a risk of explosion if battery is replaced by an incorrect type.   For disposal and replacement of a used battery, consult an authorized Andante service technician.   The Control Unit is powered by a rechargeable NiMH battery. Note that a new NiMH battery’s full performance is achieved only after two or three complete charge and discharge cycles.  The battery can be charged and discharged hundreds of times but it will eventually wear out. When the operating time is noticeably shorter than normal, it is time to replace the battery.  Do not try to remove the battery. Contact qualified service personnel to change the battery when needed. Computer     The computer should be at least 1.5m away from the patient.
Table of Contents  14  |  SmartStep™ Version 2.1.1 Revision A2   The therapist must not touch the computer and the patient simultaneously   Insole    The insole must fit the shoe size. Shoes that are too tight may result in inaccurate readings. Please note that shoe sizes vary according to manufacturers.  It is advised to change the insole once every three months. If insole use extends beyond three months, system accuracy may be affected. You will find a replacement parts order form at the end of this document.   Due to risk of transferable infections, it is highly recommended not to transfer this insole to other users.    General     The SmartStep™ system is to be used under the supervision of a physician or licensed health care provider such as a physiotherapist in rehabilitation units or clinics.                             The system is intended for indoor operation only.  Use of SmartStep™ outside the optimal range of operation (15-80 Kg) may lead to reduced accuracy of about 10%.  Always ensure that shoelaces are tightly tied and do not become tangled up with the pneumatic tubes or other components.  An improperly fitted shoe could result in distorted readings or injury.  Only use SmartStep™ on solid surfaces. Avoid rugged, uneven terrain or steep inclines.  Do not operate SmartStep™ on slick or wet surfaces.  Environments with excessive dirt, humidity, dust or debris may damage SmartStep™.   US Federal Law restricts this device to sale by or on the order of a physician.
   Classification  SmartStep™ Version 2.1.1 Revision A2  |  15  Classification  Type of protection against electric shock –  When the unit is at normal operation:  Internally powered equipment.  When the unit is at charging: Class ll.   Degree of protection against electric shock – Type BF applied part.   Classification according to the degree of protection against ingress of water – Ordinary.  Sterilization or disinfection – Not required.  Equipment not suitable for use in presence of flammable mixture with air, or with oxygen, or with nitrous oxide.  Mode of operation – Continuous operation.
Regulatory Compliance  16  |  SmartStep™ Version 2.1.1 Revision A2 Regulatory Compliance  The SmartStep system was tested and found to be in compliance with the following standards:  Safety  IEC 60601-1  IEC 60601-1-1  EMC (Electromagnetic Compatibility)  IEC 60601-1-2  ETSI EN 301 489-1 V1.5.1 (2004-09)  EN 55011 : 2003  FCC Part 15.247  FCC Statements: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment  The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  FCC ID: TWMSMARTSTEP0106
  Care and Maintenance  SmartStep™ Version 2.1.1 Revision A2  |  17  Care and Maintenance  Keep Control Unit and accessories out of reach of small children.  Keep Control Unit and accessories dry. Precipitation, humidity, and liquids contain minerals that will corrode electronic circuits.  Do not use or store Control Unit or accessories in dusty or dirty areas.   Do not store Control Unit or accessories in hot areas. High temperatures can shorten the lifespan of electronic devices, damage batteries, and warp or melt certain plastics.  Don’t store Control Unit or accessories in cold areas. When the Control Unit warms up (to its normal temperature), moisture can form inside the Control Unit, which may damage electronic circuit boards.  Don’t drop, knock, or shake the Control Unit. Rough handling can break internal circuit boards.  Don’t use harsh chemicals, cleaning solvents, or strong detergents to clean parts or accessories. Wipe with a soft cloth slightly dampened in a mild soap and water solution.
Introduction Objective Assessment  18  |  SmartStep™ Version 2.1.1 Revision A2 1 Introduction SmartStep™ was developed to assist clinicians to accurately assess, treat, and track the rehabilitation of patients who are undergoing gait training, following orthopedic or neurological impairment. 1.1 Objective Assessment SmartStep™ improves the objective assessment of different aspects of gait outcomes, by accurately measuring the ground reaction force exerted by the patient during different kinds of exercises. 1.2 Training SmartStep™ provide precise feedback in both visual and audio modes. This procedure enhances the learning process and improves movement control (weight and timing) and helps to normalize gait patterns. 1.3 Rehabilitation Tracking The SmartStep™ system records the assessment and training sessions. Historical data is collected and saved in each session for future examination. The system allows you to: 1.  Easily retrieve past sessions. 2. Analyze past sessions. 3.  Compare patient sessions in order to track rehabilitation. 1.4  Using SmartStep™ in Online and Offline Mode In assessment as well as training, the SmartStep System can be used in online or offline mode.  In online mode, SmartStep™ communicates with your computer to provide real-time visual feedback. Audio feedback is also possible. During an online session, it is recommended to work in the vicinity of the computer (in a 7m radius).   In offline mode, SmartStep™ provide real-time audio feedback. It is possible to  records session data, and downloaded it to the computer for later analysis.
System Description SmartStep™ Kit Contents SmartStep™ Version 2.1.1 Revision A2  |  19  2  System Description  2.1 SmartStep™ Kit Contents  The SmartStep™ Kit The SmartStep™ kit contains the following items: 1. 3 insoles in:   European sizes 37/8, 41/2 and 43/4      or US sizes 6/7, 8.5/10 and 10.5/11.5.  2. Control Unit with strap (which includes a plastic cover for the Charging connector).  3. Manual pump. 4. Battery charger for the Control Unit  5. SmartStep software CD. 6. Bluetooth USB adapter.  7. Bluetooth USB adaptor driver installation CD.  8. Quick User’s guide. If any of the above items are missing, or appear damaged, please contact your supplier.
System Description SmartStep™ Components  20  |  SmartStep™ Version 2.1.1 Revision A2  2.2 SmartStep™ Components SmartStep™ consists of four main components: An insole, Control Unit, software and a manual pump. The following sections explain each of these components in more detail. 2.2.1 Insole  Insole The SmartStep™ insole is placed inside the patient’s shoe, and is used to measure the force exerted by the patient on the foot, during an assessment or a training session.  The insole contains two inflatable compartments – the forefoot and the hind foot. Each compartment is connected, via a tube, to a pressure sensor. When a patient exerts force on the leg, increased air is driven out of the air pockets and is detected by the pressure sensors and converted into uneven weight in Kg/lb. SmartStep™ sessions are performed on a single foot at a time. The insole is suitable for both left and right feet. It is supplied in a range of sizes (see details in 2.1 above).
System Description Control Unit SmartStep™ Version 2.1.1 Revision A2  |  21  2.2.2 Control Unit   The Control Unit  The SmartStep™ Control Unit serves three purposes:  Data relay to a computer via wireless (Bluetooth) communication. The computer must have the SmartStep™ software installed (see  3.2). Connecting the Control Unit to a computer allows you to view a graph of the gait pattern, as the patient performs an online workout.   Feedback generation when the patient reaches and exceeds the desired weight range. Audio feedback is optional; it can be turned on and off by toggling the Control Unit’s operation mode.  Optional data collection in an offline mode that can be turned on or off by toggling the Control Unit’s operating mode. The collected data can be downloaded to a computer and view session statistics and graphs.
System Description Control Unit  22  |  SmartStep™ Version 2.1.1 Revision A2  Control Unit Modes of Operation  Operation mode Name Description 0 On  Control Unit is on. 1 Online Assessment Online assessment mode (when no weight thresholds are determined) with graphic visual feedback of patient performance.  1. Offline Assessment and Data collection Offline assessment mode (when no weight thresholds are determined). Data is collected. Later it is possible to save it in the patient’s file. 2 Online/Offline Training Online/Offline training mode (when weight thresholds are determined). Audio feedback is available in the form of beeps to alert patient and/or therapist to weight exerted by the patient. In Online mode graphic visual feedback is available as well.  2. Offline Training and Data collection Offline training mode (when weight thresholds are determined). Data is collected. Later it is possible to save it in the patient’s file. Audio feedback is available in the form of beeps to alert the patient and/or therapist to weight exerted by the patient. 4 Download Completed Data collected offline has successfully been downloaded to the computer. After a pause, mode reverts to 1 or 2 (without the dot, depending on the mode before the download process). 4. Download in Progress Data collected offline is being downloaded to the computer. When download is complete, the mode reverts to 4 (without the dot). E  Air Pressure Error  Incorrect initial air pressure. C Wireless Error Wireless connection was lost. S Sensor Problem Sensor error detected. P  Low Air Pressure  Air pressure is lost in insole compartments (hind and/or fore). H Maximum Values  Exceeded   System exceeded maximum values.      L Low Battery The unit is turned off automatically.
System Description SmartStep™ Software SmartStep™ Version 2.1.1 Revision A2  |  23   2.2.3 SmartStep™ Software The desktop software is used to perform the following functions:  Monitor gait parameters.  Display visual feedback.  Show results and statistics from Online/Offline sessions.  Track rehabilitation progress.   2.2.4 Manual Pump  The Manual Pump The manual pump is designed to inflate the two compartments with air. The manual pump is not connected directly to the insole. The inflation is done via the Control Unit.
Installation System Requirements  24  |  SmartStep™ Version 2.1.1 Revision A2 3 Installation 3.1 System Requirements  Microsoft Windows® XP Professional or Home Edition.  128 MB of RAM minimum, 256 MB or greater recommended.   Up to 20 MB of available hard-disk space.   3.2  SmartStep Software Installation 1. Insert the SmartStep Installation disk into the CD-ROM drive.  2. Open the CD-ROM root folder and double click on the SmartStep icon.
Installation SmartStep Software Installation SmartStep™ Version 2.1.1 Revision A2  |  25    3. Click Next.      4. It is recommended to use the default destination folder. Click Next.
Installation SmartStep Software Installation  26  |  SmartStep™ Version 2.1.1 Revision A2  5. It is recommended to check the Create a desktop icon check-box. Click Next.     6. Click Install.
Installation SmartStep Software Installation SmartStep™ Version 2.1.1 Revision A2  |  27   7. Click Finish.      SmartStep installation is now complete. The next step is the Bluetooth USB Adapter installation.
Installation Bluetooth USB Adapter Driver Installation  28  |  SmartStep™ Version 2.1.1 Revision A2 3.3  Bluetooth USB Adapter Driver Installation        To avoid software installation problems, please do NOT insert the Bluetooth USB Adapter until the installation displays a message to do so (step8).    1. Insert the USB Adapter installation disk into the CD-ROM drive. The Setup program should launch automatically. Click the Install Software button.    2. Click the Next button.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  29   3. Choose the I accept… option, and click the Next button.       4. In this screen it is possible to change the destination folder by clicking the Change… button. It is recommended to use the default destination folder. Click Next.
Installation Bluetooth USB Adapter Driver Installation  30  |  SmartStep™ Version 2.1.1 Revision A2    5. Click Install. The installation might take several minutes.      6. If the dialog below opens, click Cancel.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  31     7. If the dialog below opens, click on the Continue Anyway button.      8. A message box indicating that No Bluetooth device was detected should popup. Please insert the Bluetooth USB adapter and click OK.
Installation Bluetooth USB Adapter Driver Installation  32  |  SmartStep™ Version 2.1.1 Revision A2   9. Click Finish.      10. Click Exit.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  33    11. Double click on the My Bluetooth Places icon on the desktop. It is also possible to double click the Bluetooth icon that is located in the notification area of the taskbar, or to right click it and select Start Using Bluetooth.            12. Click Next.
Installation Bluetooth USB Adapter Driver Installation  34  |  SmartStep™ Version 2.1.1 Revision A2  13. Click Next.     14. Click Next.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  35   15. Leave the default settings. Click Next.    16. Click Skip.
Installation Bluetooth USB Adapter Driver Installation  36  |  SmartStep™ Version 2.1.1 Revision A2  17. Click Finish.      18. Double click the My Bluetooth Places icon on the desktop.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  37  19. Turn the Control Unit on.        In the Bluetooth Tasks menu, click the View Devices in Range option.      20. The list should contain only devices that were already connected to the computer. In the Bluetooth Tasks menu click the Search for Devices in Range option.
Installation Bluetooth USB Adapter Driver Installation  38  |  SmartStep™ Version 2.1.1 Revision A2  21. Right-click the icon marked with the circle (the icon with the question mark on) . Choose the Properties option.    22. Make sure that the device address matches the address on the back of the Control Unit. The 4 characters marked in the screenshot are the Bluetooth Pin Code. Close the window by clicking OK.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  39    23. Right click the icon marked with the circle (the icon with the question mark on). Choose the Pair Device option.      24. Enter the four letter Bluetooth Pin Code (marked in the screenshot in step 22). Use capital letters only. Click OK.
Installation Bluetooth USB Adapter Driver Installation  40  |  SmartStep™ Version 2.1.1 Revision A2  25. Double click the icon marked with a circle (the icon with the question mark on).       26. Right click the icon below and choose the Create Shortcut option.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  41   27. Click the OK button.      28. Choose the My Bluetooth Places option, in the Other Places menu.     29. Right-click the marked icon, and Rename it for later easy recognition.
Installation Bluetooth USB Adapter Driver Installation  42  |  SmartStep™ Version 2.1.1 Revision A2    30. Right-click the marked icon again, and choose the Properties option.  31. Uncheck the Secure Connection checkbox. Click OK.      32. In the Taskbar notification area right-click the marked icon. Choose the Advanced Configuration option.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  43     33. Select the Client Applications tab. Select the Bluetooth Serial Port list item and click the Properties… button.      34. Uncheck the Secure Connection checkbox. Click OK.
Installation Bluetooth USB Adapter Driver Installation  44  |  SmartStep™ Version 2.1.1 Revision A2  35. Choose the Local Services tab. Select the Bluetooth Serial Port list item and click the Properties… button.      36. Uncheck the Secure Connection and the Startup Automatically checkboxes. Click OK.
Installation Bluetooth USB Adapter Driver Installation SmartStep™ Version 2.1.1 Revision A2  |  45  37. Double-click the My Bluetooth Places icon on the desktop.    38. Double-click the icon you named in step 29.     39. The location of the serial port number that is required by the SmartStep program is marked in the screenshot. Click OK.    40. The icon should change to the icon shown below, the control unit beeps twice to indicate that the connection with the device has taken place .
Installation SmartStep™ Antenna Installation Instructions  46  |  SmartStep™ Version 2.1.1 Revision A2  The Bluetooth icon that is located in the notification area of the taskbar can be one of the following colors:  White - The adapter is connected and enabled. Red - The adapter is not connected to the USB port. Bluetooth support is disabled. Green - Bluetooth communication was established.        3.4  SmartStep™ Antenna Installation Instructions • No antenna installation is needed. • Antenna is internal and assembly on the PCB (Printed Circuit Board)  3.5  Configure SmartStep™ for Bluetooth Usage   Make sure that the Bluetooth USB adapter is placed at a location free from signal obstruction. Concrete walls, metal substances, paints with metal composites, etc. may cause signal obstruction and disable the Bluetooth function.      1. Start the SmartStep™ software, by double-clicking on the desktop shortcut icon   Or by clicking on the SmartStep shortcut in the Start->Program Files->SmartStep program group.
Installation Configure SmartStep™ for Bluetooth Usage SmartStep™ Version 2.1.1 Revision A2  |  47    2. The Login dialog box opens.     3. Select your User Name from the drop-down menu and type your Password in the edit box.  4. Click the OK button to log in. 5. In the Select Patient window, go to the System menu and select System Configuration.     6. In the Configuration window select the correct Bluetooth port number and click OK. See step 39 of the Bluetooth USB adapter Installation section.

Navigation menu