Andersen CB000106458 Intrusion Detector-400-DH Sensor User Manual
Andersen Corporation Intrusion Detector-400-DH Sensor Users Manual
Andersen >
Users Manual
VeriLock® Security Sensor Application VeriLock® Security Sensor Application for Andersen® A-Series Double-Hung Windows for Andersen® A-Series Double-Hung Windows Thank you for choosing Andersen. / Gracias por elegir Andersen. For questions call 1-888-888-7020. For more information and/or guides visit andersenwindows.com. Please leave this guide with building owner. Si tiene alguna pregunta llame al 1-888-888-7020. Para obtener más información y/o guías, visite andersenwindows.com. Deje esta guía con el dueño de la construcción. ▶▶ Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Lea completamente la guía antes de comenzar la instalación. Lea y respete todas las advertencias y precauciones durante la instalación de la unidad. ▶▶ Check with your local building code official to identify and confirm compliance with local building code requirements. Consulte los códigos locales de construcción para identificar y confirmar que se cumplan los requisitos del código de construcción. Tools Needed / Herramientas Necesarias ∙∙ Safety Glasses / Lentes de seguridad ∙∙ Phillips Screwdriver /Destornillador Phillips Parts (1) (4) (4) (1) (1) (1) (8) (1) Included / Partes Incluidas VeriLock Sensor / VeriLock Sensor VeriLock Active Cover / VeriLock Active Cover Lock Magnet / Lock Magnet Keeper Magnet / Keeper Magnet CR-2025 Battery / CR-2025 Battery #8 x 1" Screw Tornillo No. 8 x 1" Battery Cap / Battery Cap #8 x 1" Screw (color matched) / #8 x 1" Screw (color matched) Cleaning Wipe / Cleaning Wipe Additional Parts Required for Units with Two Locks Additional Parts Required for Units with Two Locks (4) VeriLock Dummy Cover / VeriLock Dummy Cover #8 x 1" Screw (8) #8 x 1" Screw (color matched) / Tornillo No. 8 x 1" #8 x 1" Screw (color matched) VeriLock® Dummy Cover VeriLock® Dummy Cover Keeper Magnet Keeper Magnet Lock Magnet Lock Magnet VeriLock® Active Cover VeriLock® Active Cover Battery Cap Battery Cap VeriLock Sensor VeriLock Sensor CR-2025 Battery CR-2025 Battery Use caution when working at elevated heights and around unit openings. Follow manufacturers’ instructions for ladders and/or scaffolding. Failure to do so may result in injury or death. Sea cauteloso al trabajar en lugares elevados y cerca de las aberturas de la unidad. Siga las instrucciones del fabricante para el uso de escaleras y/o andamios. Si no lo hiciera, podrían producirse lesiones o la muerte. NOTE: VeriLock dummy cover is installed on the left lock of units with two locks, as viewed from the interior. NOTE: VeriLock dummy cover is installed on the left lock of units with two locks, as viewed from the interior. Follow manufacturers’ instructions for hand or power tools. Always wear safety glasses. Failure to do so may result in injury and/or product damage. Siga las instrucciones del fabricante para el uso de herramientas eléctricas o manuales. Utilice siempre gafas de seguridad. Si no lo hiciera, podrían producirse lesiones y/o daños al producto. “Andersen” and all other marks where denoted are trademarks of Andersen Corporation and its subsidiary. © 2016 Andersen Corporation. All rights reserved. “Andersen” y todas las demás marcas que aparezcan son marcas registradas de Andersen Corporation y su subsidiaria © 2016 Andersen Corporation. Todos los derechos reservados. 9 1 4 2 1 9 5 BA - 0 1 Revised 03/09/16 Batteries carry the risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212 degrees F (100 degrees C) or incinerate. Dispose of used batteries promptly and properly. Keep away from children. Les piles représentent un risque d’incendie, d’explosion et de brûlures. Ne pas recharger, démonter, chauffer à une température excédant 100 degrés C (212 degrés F) ou incinérer. Éliminer les piles rapidement et de manière appropriée. Garder à l’écart des enfants. Magnetic field can be harmful to implanted medical device wearers. Keep magnets away from devices. Magnetic field can be harmful to implanted medical device wearers. Keep magnets away from devices. Batteries are small parts and, if swallowed, could pose a choking hazard to young children. Magnets are small parts and, if swallowed, could pose a choking hazard to young children. Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asfixia para niños pequeños. Las baterías son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asfixia para niños pequeños. (top view) (top view) Interior Interior (bottom view) (bottom view) Battery Cap Battery Cap Indicator Light Indicator Light VeriLock Sensor VeriLock Sensor CR-2025 Battery CR-2025 Battery Insert battery into VeriLock sensor (+) facing out. Indicator light will illuminate for one (1) second when battery is installed correctly. Insert battery into VeriLock sensor (+) facing out. Indicator light will illuminate for one (1) second when battery is installed correctly. Interior Position battery cap over battery with edges tightly sealed. Make sure all cap edges are sealed around the battery ring. Position battery cap over battery with edges tightly sealed. Make sure all cap edges are sealed around the battery ring. VeriLock® Active Cover VeriLock® Active Cover Adhesive Liner Adhesive Liner VeriLock Assembly VeriLock Assembly VeriLock Sensor VeriLock Sensor Select preferred color VeriLock active cover. Remove adhesive liner from sensor and press sensor firmly into backside of VeriLock active cover as shown. Select preferred color VeriLock active cover. Remove adhesive liner from sensor and press sensor firmly into backside of VeriLock active cover as shown. 9142195 4 Interior Interior Phillips Screwdriver Destornillador Phillips Lock Cerrojo Unlock and open bottom sash. Desbloquee y abra la hoja inferior. Interior NOTE: VeriLock sensor is installed on the right lock of units with two locks, as viewed from the interior. NOTE: VeriLock sensor is installed on the right lock of units with two locks, as viewed from the interior. Remove screws from lock and dispose of properly. Do not remove or lift lock after unscrewing. Retire los tornillos del cerrojo y deséchelos adecuadamente. Do not remove lock after unscrewing. Lock Cerrojo #8 x 1" Screw #8 x 1" Screw VeriLock Assembly VeriLock Assembly Position VeriLock assembly around lock as shown. Fasten using #8 x 1" color matched screws provided. Do not over tighten screws. Position VeriLock assembly around lock as shown. Fasten using #8 x 1" color matched screws provided. Do not over tighten screws. Interior Lock Handle Lock Handle Position magnet as shown with arrow pointing up. Position magnet as shown with arrow pointing up. Lock Magnet Lock Magnet Adhesive Liner Adhesive Liner Clean area on lock handle to receive lock magnet with cleaning wipe provided. Remove adhesive liner press magnet firmly on lock handle with arrow pointing up as shown. Clean area on lock handle to receive lock magnet with cleaning wipe provided. Remove adhesive liner press magnet firmly on lock handle with arrow pointing up as shown. 9142195 For Units with Two Locks Only / For Units with Two Locks Only VeriLock Dummy Cover VeriLock Dummy Cover Interior Remove screws from left lock and dispose of properly. Do not remove lock. Position VeriLock dummy cover around left lock and fasten using #8 x 1" color matched screws provided. Do not over tighten screws. Remove screws from left lock and dispose of properly. Do not remove lock. Position VeriLock dummy cover around left lock and fasten using #8 x 1" color matched screws provided. Do not over tighten screws. Interior >100º NOTE: Set window on a support object at an angle greater than 100 degrees. NOTE: Set window on a support object at an angle greater than 100 degrees. Retract tilt latches by pushing lock handle(s) outward. Tilt bottom sash in and support. Retract tilt latches by pushing lock handle(s) outward. Tilt bottom sash in and support. 10 Interior Keeper Keeper Keeper Magnet Keeper Magnet NOTE: Magnet is installed on the right keeper of units with two locks, as viewed from the interior. NOTE: Magnet is installed on the right keeper of units with two locks, as viewed from the interior. Adhesive Liner Adhesive Liner Clean area on keeper to receive magnet with cleaning wipe provided. Remove adhesive liner and position keeper magnet as shown. Press firmly in place. Clean area on keeper to receive magnet with cleaning wipe provided. Remove adhesive liner and position keeper magnet as shown. Press firmly in place. 9142195 11 Interior Retract tilt latches by pushing lock handle(s) outward and tilt sash up. Close and lock sash. Retract tilt latches by pushing lock handle(s) outward and tilt sash up. Close and lock sash. Verify VeriLock Sensor Function / Verify VeriLock Sensor Function 12 Interior Locked Locked Unlocked Unlocked 1. 2. 3. 4. Raise lower sash from closed position. Indicator light will illuminate for one (1) second. Close lower sash so the lock aligns with the keeper. Indicator light will illuminate for one (1) second. Lock window. Indicator light will illuminate for one (1) second. Unlock window. Indicator light will illuminate for one (1) second. 1. 2. 3. 4. Raise lower sash from closed position. Indicator light will illuminate for one (1) second. Close lower sash so the lock aligns with the keeper. Indicator light will illuminate for one (1) second. Lock window. Indicator light will illuminate for one (1) second. Unlock window. Indicator light will illuminate for one (1) second. Verify VeriLock sensor function. If indicator light does not respond as described, verify sensor application and magnet placement. Verify VeriLock sensor function. If indicator light does not respond as described, verify sensor application and magnet placement. ▶▶ Procedure is complete. Procedure is complete. Refer to monitoring system of your choice for sensor enrollment. Refer to monitoring system of your choice for sensor enrollment. For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide. For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide. 9142195 Regulatory Statements / Regulatory Statements Federal Communications Commission (FCC) Part 15 Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation. Industry Canada (IC) RSS Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de I'appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by Andersen may void the user's authority to operate the equipment. 9142195
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:4cfacc6c-8378-964a-b07a-52668e57b5de Original Document ID : adobe:docid:indd:d0717119-dfee-11de-8e34-9beae8c19d6b Document ID : xmp.id:1ac7c962-8bb9-4a38-b24e-6b475c957544 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:f14687b9-86d3-4608-9847-4f5bf94e9d93 Derived From Document ID : xmp.did:c3d094e6-ec0d-42bf-9d93-f1b3f25e9b35 Derived From Original Document ID: adobe:docid:indd:d0717119-dfee-11de-8e34-9beae8c19d6b Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2016:03:09 15:47:11-06:00 Create Date : 2016:03:09 15:47:11-06:00 Modify Date : 2016:03:09 15:48:19-06:00 Metadata Date : 2016:03:09 15:48:19-06:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Slug Family : Helvetica Slug Version : 001.004 Slug Outline File Size : 30185 Slug Kerning Checksum : 55007 Slug Foundry : Adobe Systems Slug Font Kind : PostScript Slug Checksum : 3285313313 Slug Post Script Name : Helvetica-Condensed Slug Font Sense 12 Checksum : 3285313313 Page Layout : SinglePage Page Mode : UseThumbs Page Count : 6 Creator : Adobe InDesign CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools