Andrew Base Station Subsystems Group AA190045 RRH 2x45W 1900MHz AA190045 RF151032 User Manual

Andrew Corporation, Base Station Subsystems Group RRH 2x45W 1900MHz AA190045 RF151032

Contents

Installation Manual

Download: Andrew Base Station Subsystems Group AA190045 RRH 2x45W 1900MHz AA190045 RF151032 User Manual
Mirror Download [FCC.gov]Andrew Base Station Subsystems Group AA190045 RRH 2x45W 1900MHz AA190045 RF151032 User Manual
Document ID2019620
Application IDcuz8rPXRuNcOHOfFEaLk7g==
Document DescriptionInstallation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize35.13kB (439069 bits)
Date Submitted2013-07-18 00:00:00
Date Available2013-07-18 00:00:00
Creation Date2013-07-17 19:14:00
Producing Software1.0.0.15
Document Lastmod2013-07-17 20:08:39
Document Titleuntitled
Document CreatorCIDEON Conversion Engine

Installation Instructions
Mounting Kits For Wide Panel Antennas
BSAMNT Series: Mounting systems for cylindrical pipe
installations (60-115mm pipe diameter) for heavy duty applications
ITEM NO.
10
11
12
13
14
DESCRIPTION
PIPECLAMP BRACKET, NO FLANGE
PIPECLAMP BRACKET, SHORT FLANGES
NOTCHED BRACKET
BRACKET
SCR,HCS,HEX,M8X25,STL,GALV
WSHR,LK,SPLT,M8,STL,GALV
TWO HOLE PLATE, 8mm X 1.25 PITCH
NUT,HEX,M10,STL,GALV
WSHR,LK,SPLT,M10,STL,GALV
SCR,HCS,HEX,M10X40,STL,GALV
NUT,HEX,M12,STL,GALV
WSHR,FLT,M12,13X28X2.5,STL,GALV
WSHR,LK,SPLT,M12,STL,GALV
BOLT,CARRIAGE,M12 X 200,STL,GALV
Bulletin 639825-1 • Revision B • March 2013
Page 1 of 2
Andrew Institute offers installation training.
QTY
U/M
12
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
Part Lists
two hole plate
M8 bolt
• Bracket edges parallel to each other.
(fully collapsed position)
Pre-assembly of Downtilt Brackets
MAXIMUM TORQUE
M8
15N.m (11ft.lbs)
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
M10 bolt
M10 bolt
10
10
M12 bolt
14
12
13
11
CRITICAL: For initial installation
to pipe, downtilt brackets must
be configured in pre-assembly
position (fully collapsed).
ATTENTION: Insert M12 bolts and M12
flat washers into bracket with tabs
prior to attaching bracket to antenna.
Top / Middle Mount Installations
BSAMNT Mounting Kit
CommScope
Bulletin 639825-1 • Revision B • March 2013 Page 2 of 2
(Continued from page 1)
MAXIMUM TORQUE
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
M12 bolt
14
12
13
11
10
M10 bolt
ATTENTION: Insert M12 bolts and M12
flat washers into bracket with tabs
prior to attaching bracket to antenna.
Bottom Mount Installation
• Loosen pivot bolts . (do
not remove)
M10 pivot bolt
(loosen only)
M10 pivot bolt
(loosen only)
• Remove adjuster bolts.
M8 adjuster bolt
perimeter location
(remove to adjust tilt)
• Adjust antenna angle.
(use inclinometer)
M10 pivot bolt
(loosen only)
• Reinstall adjuster bolts.
• Retighten all bolts.
use inclinometer to
adjust antenna angle
M8 pivot bolt
center location
(loosen only)
M10 pivot bolt
(loosen only)
DETAIL A
MAXIMUM TORQUE
15N.m (11ft.lbs)
M8
37N.m (27ft.lbs)
M10
M12
58N.m (43ft.lbs)
Adjusting Antenna Tilt
SAFETY NOTICE
The installation, maintenance, or removal of an antenna
requires qualified, experienced personnel. CommScope
installation instructions are written for such installation
personnel. Antenna systems should be inspected once a
year by qualified personnel to verify proper installation,
maintenance, and condition of equipment.
CommScope disclaims any liability or responsibility for the
results of improper or unsafe installation practices.
It is recommended that transmit power be turned off
when the field installation is performed. Follow all
applicable safety precautions as shown on this page.
CommScope
Customer Support Center
North America: +1-800-255-1479, Option 1
International: +1-779-435-6500, Option 1
Email:
BSASupport@CommScope.com
Do not install near power lines.
Power lines, telephone lines,
and guy wires look the same.
Assume any wire or line can
electrocute you.
Do not install on a wet or windy
day or when lightning or thunder
is in the area. Do not use metal
ladder.
Wear shoes with rubber soles and
heels. Wear protective clothing
including a long-sleeved shirt and
rubber gloves.
www.commscope.com/andrew
Visit our Web site at www.commscope.com or contact your local sales representative for more information.
© 2012 CommScope, Inc. All rights reserved.
Andrew is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or trademarks,
respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement
any specifications or warranties relating to Andrew products or services.
RF Safety Warning:
Although the final configurations are determined at time of licensing, it is important that the antenna
selection and installation do not exceed equipment authorization and adequate separation distance is
maintained. One of investigated configurations is that RRH 2x45 MHz has an output EIRP of 5.2kW and a
minimum RF safety separation distance of 6.4 meters with max gain 17.5 dBi.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2013:07:17 19:14:00-04:00
Creator                         : CIDEON Conversion Engine
Modify Date                     : 2013:07:17 20:08:39-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2013:07:17 20:08:39-04:00
Creator Tool                    : CIDEON Conversion Engine
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:3f106c12-2c37-4e3c-876d-3af548f3bc6f
Instance ID                     : uuid:02a0b006-0480-4cf2-b145-f41f8d3f094d
Producer                        : 1.0.0.15
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S8L-AA190045

Navigation menu