Andrew Base Station Subsystems Group AA190045 RRH 2x45W 1900MHz AA190045 RF151032 User Manual
Andrew Corporation, Base Station Subsystems Group RRH 2x45W 1900MHz AA190045 RF151032
Contents
- 1. Installation Manual
- 2. Users Manual
Installation Manual
Installation Instructions Mounting Kits For Wide Panel Antennas BSAMNT Series: Mounting systems for cylindrical pipe installations (60-115mm pipe diameter) for heavy duty applications ITEM NO. 10 11 12 13 14 DESCRIPTION PIPECLAMP BRACKET, NO FLANGE PIPECLAMP BRACKET, SHORT FLANGES NOTCHED BRACKET BRACKET SCR,HCS,HEX,M8X25,STL,GALV WSHR,LK,SPLT,M8,STL,GALV TWO HOLE PLATE, 8mm X 1.25 PITCH NUT,HEX,M10,STL,GALV WSHR,LK,SPLT,M10,STL,GALV SCR,HCS,HEX,M10X40,STL,GALV NUT,HEX,M12,STL,GALV WSHR,FLT,M12,13X28X2.5,STL,GALV WSHR,LK,SPLT,M12,STL,GALV BOLT,CARRIAGE,M12 X 200,STL,GALV Bulletin 639825-1 • Revision B • March 2013 Page 1 of 2 Andrew Institute offers installation training. QTY U/M 12 EA EA EA EA EA EA EA EA EA EA EA EA EA EA Part Lists two hole plate M8 bolt • Bracket edges parallel to each other. (fully collapsed position) Pre-assembly of Downtilt Brackets MAXIMUM TORQUE M8 15N.m (11ft.lbs) M10 37N.m (27ft.lbs) M12 58N.m (43ft.lbs) M10 bolt M10 bolt 10 10 M12 bolt 14 12 13 11 CRITICAL: For initial installation to pipe, downtilt brackets must be configured in pre-assembly position (fully collapsed). ATTENTION: Insert M12 bolts and M12 flat washers into bracket with tabs prior to attaching bracket to antenna. Top / Middle Mount Installations BSAMNT Mounting Kit CommScope Bulletin 639825-1 • Revision B • March 2013 Page 2 of 2 (Continued from page 1) MAXIMUM TORQUE M10 37N.m (27ft.lbs) M12 58N.m (43ft.lbs) M12 bolt 14 12 13 11 10 M10 bolt ATTENTION: Insert M12 bolts and M12 flat washers into bracket with tabs prior to attaching bracket to antenna. Bottom Mount Installation • Loosen pivot bolts . (do not remove) M10 pivot bolt (loosen only) M10 pivot bolt (loosen only) • Remove adjuster bolts. M8 adjuster bolt perimeter location (remove to adjust tilt) • Adjust antenna angle. (use inclinometer) M10 pivot bolt (loosen only) • Reinstall adjuster bolts. • Retighten all bolts. use inclinometer to adjust antenna angle M8 pivot bolt center location (loosen only) M10 pivot bolt (loosen only) DETAIL A MAXIMUM TORQUE 15N.m (11ft.lbs) M8 37N.m (27ft.lbs) M10 M12 58N.m (43ft.lbs) Adjusting Antenna Tilt SAFETY NOTICE The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment. CommScope disclaims any liability or responsibility for the results of improper or unsafe installation practices. It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page. CommScope Customer Support Center North America: +1-800-255-1479, Option 1 International: +1-779-435-6500, Option 1 Email: BSASupport@CommScope.com Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you. Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder. Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves. www.commscope.com/andrew Visit our Web site at www.commscope.com or contact your local sales representative for more information. © 2012 CommScope, Inc. All rights reserved. Andrew is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew products or services. RF Safety Warning: Although the final configurations are determined at time of licensing, it is important that the antenna selection and installation do not exceed equipment authorization and adequate separation distance is maintained. One of investigated configurations is that RRH 2x45 MHz has an output EIRP of 5.2kW and a minimum RF safety separation distance of 6.4 meters with max gain 17.5 dBi.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2013:07:17 19:14:00-04:00 Creator : CIDEON Conversion Engine Modify Date : 2013:07:17 20:08:39-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2013:07:17 20:08:39-04:00 Creator Tool : CIDEON Conversion Engine Format : application/pdf Title : untitled Document ID : uuid:3f106c12-2c37-4e3c-876d-3af548f3bc6f Instance ID : uuid:02a0b006-0480-4cf2-b145-f41f8d3f094d Producer : 1.0.0.15 Page Count : 3EXIF Metadata provided by EXIF.tools