Andrew Wireless Innovations Group BCEL-1915BA TFB 1915 BOOSTER AMP User Manual MN004 00

Andrew Wireless Innovations Group TFB 1915 BOOSTER AMP MN004 00

USER GUIDE

OPERATIVE ANDOPERATIVE ANDMAINTENANCEMAINTENANCEHANDBOOKHANDBOOK  Copyright 1998Tekmar Sistemi S.r.l.All Rights Reserved
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.2/15SYSTEM: BRITECELL Class 1 (High Dynamic Range)OPERATING BAND:  Rel.00-980408¨  AMPS 800 + DCS 1800¨  AMPS 800 + PCS 1900¨  GSM 900 + DCS 1800¨  GSM 900 + PCS 1900INDEX1. DECLINE OF RESPONSIBILITY.................................................................................... 32. CONFORMITY DECLARATION ..................................................................................... 43. INSTALLATION CONDITIONS....................................................................................... 54. ASSISTANCE AND WARRANTY CONDITIONS............................................................ 65. WARNING LABELS........................................................................................................ 76. SYSTEM THEORY ......................................................................................................... 87. TECHNICAL DETAILS ................................................................................................... 97.1 OPTICAL CONNECTORS......................................................................................... 97.2 LOCAL INTERFACE.................................................................................................. 97.2.1 6HE SUBRACK TPR912............................................................................................................. 97.2.2 PLUG IN LOCAL INTERFACE MODULE.................................................................................... 97.2.3 STANDALONE LOCAL INTERFACE UNIT............................................................................... 107.2.4 TFL BSI .................................................................................................................................... 117.2.5 CROSSBAND COUPLER TLC2501.......................................................................................... 117.2.6 2-WAYS RF COMBINER TLC 2502/TFL-UDD.......................................................................... 117.2.7 3-WAYS RF COMBINER TLC 2503.......................................................................................... 117.2.8 PAGER DL COMBINER TLC-DB.............................................................................................. 117.3 REMOTE RF OPTICAL TRANSCEIVER................................................................. 117.3.1 PAGER REMOTE PANEL ACTIVE ANTENNA TPA320 ........................................................... 127.3.2 MINIPANEL ANTENNA TPA302............................................................................................... 127.3.3 FLAT PANEL MULTIBAND ANTENNA TPA 3020..................................................................... 127.3.4 DOWNLINK AGC ..................................................................................................................... 127.3.5 UPLINK GAIN SETTING........................................................................................................... 127.3.6 POWER SUPPLY..................................................................................................................... 138. INSTALLATION HINTS ................................................................................................ 148.1 INSTALLATION OF LOCAL INTERFACE ............................................................... 148.2 INSTALLATION OF REMOTE RF OPTICAL TRANSCEIVER ................................ 149. POWER LEVELS.......................................................................................................... 14
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.3/151. DECLINE OF RESPONSIBILITYThis handbook provides all necessary information about the device, namely:• installation• usage and possible problem solving• maintenanceTekmar Sistemi advises the accurate reading of this handbook and the respect of theoperating instructions given here below, in order to get all necessary information for acorrect installation, usage and maintenance of the device.Tekmar Sistemi declines all responsibilities with respect to any possible damage  due toan inappropriate usage of this handbook, or to a non-compliance of the rules set up in thishandbook.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.4/152. CONFORMITY DECLARATIONTekmar Sistemi S.r.l.  DECLARES :that the device related to this usage and maintenance handbook comply with the CEmark requirements, according to the Low Tension Rules 73/23/CEE  and Electro-magneticcompatibility Rules 89/392/CEE , and particularly with the following laws and rules :EN RulesIEC RulesTekmar Sistemi will carefully retain the technical file related to the device design, togetherwith this usage and maintenance handbook, for a minimum time span of 10 years.Signature : Legal Representative of Tekmar Sistemi S.r.l.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.5/153. INSTALLATION CONDITIONSEnvironmental Conditions :Temperature : 5-40°CChemical materials : Do not install in corrosive atmosphere or environments, in anyenvironment  with explosive materials or with inflammablesubstances ;Installation site features:The installation of the rack has to be carried out by proper and competent staff. Besides,the system is supposed to be used for indoor installation.The rack has to be positioned in indoor environments, dry and suitable for this purpose,i.e.:• no explosion risks is present ;• the environment is not classified as a high-risk one in case of fire;• powders in suspension are not to be found in great concentration;• the environment is not subject to any traffic which could cause crash damages;• the site is properly located with respect to the ergonomic positioning of the workingenvironments ;• the system is placed in a private room, protected against any possible violation .Connection to the electrical networkThe connection to the electrical network has to be carried out following all necessaryprecautions , and namely :• it must be properly made according to the due diligence rules (ex. : CEI rules, IECrules, etc.) ;• in accordance with the rules for the safety against direct or indirect contacts;• in accordance with the rules for the safety against the overcurrent (short circuit,overloading);• in accordance with the rules for the safety against the overtensions;• the connection is to be carried out by proper and competent staff
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.6/15 4. ASSISTANCE AND WARRANTY CONDITIONSTekmar Sistemi S.r.l. grants an assistance service for all its products, either under or out ofwarranty .The warranty period for each product is mentioned on the Supply Contract. In case no specifictime period is mentioned, the warranty is supposed to be valid for a time span of 12 monthsafter the date of the Delivery Note.The product is to be considered under warranty (according to the Italian D.P.R. 24/05/1988 n.224) only on occurrence of the following conditions :a)  The warranty period is not expired;b)  The defect is imputable to the product .The warranty expires if :• The product shows violations and/or modifications effected by the customer;• The fault is due to improper use, maintenance or installation.The Assistance Service at Tekmar Sistemi evaluates if the product can be repaired or if it isnecessary to replace the unit.In case the product is out of warranty, the customer is supposed to be charged with therepair/replacement cost, according to the quotation issued by the manufacturer.  Theintervention takes place only after the customer has acknowledged the quotation andauthorised the repair.Before returning the goods, the customer is supposed to give prior notice to Tekmar Sistemi,which will provide the necessary authorisation.In order to obtain a fast and proper assistance, the customer should attach to the lot anaccompanying letter, including the following information:Ref. : Invoice No.Ref. : Delivery NoteProduct References : N° of pieces,  Model,  Serial NumberDefect report  Tekmar Assistance Service issues a check report which is included in the packingtogether with the product being returned.If any Corrective Action is proposed by the Quality Assurance, the customer is informedabout it via fax.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.7/155. WARNING LABELS                            Meaning: Attention -  Flat polished connector.                            Meaning: Attention - Angle polished connector.                            Meaning: Attention -  possible invisible laser radiation from this aperture -flat polished connectors.                            Meaning: attention - possible invisible laser radiation from this aperture -angle polished connectors.Meaning: attention - possible invisible laser radiation, max. power 30mW,wavelength 1300nm, laser product class III b.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.8/156. SYSTEM THEORYBRITECELL is an RF distribution/concentration system, based on electrical to optical conversion,and fibre transmission.It is mainly intended for cellular indoor coverage, because of its intrinsic high dynamic range, andRF performances.The DUAL BAND system provides coverage for two bands :one in the 800-1000 MHz range theother in the 1700-2000 MHz1.A local interface (composed of 6 plug in local interface modules or of 1 standalone local interfaceunit) provides RF connection with BTS and conversion to optical in both UL and DL paths; eachLocal interface has a single RF connector per path, while four optical connectors per path areprovided to interface the fibre cables driving the remote units.The local interface modules can be combined in groups of two or three through one or more RFcombiners, according to the specific coverage and indoor cells design.The local interface contains the required auxiliary circuitry, including AC mains power supply.The remote transceivers provide air-interface to coverage area; each of them includes a high-efficiency surface antenna, RF to optical interface in both UL and DL paths, RF LNA and PA,control and auxiliary functions, and AC mains power supply.An auxiliary RF port is available, to additionally connect a passive antenna for better coverageshaping. The RF combiner is taken as part of the antenna feeder; the related loss is 3.8dB perarm. The system can be provide with a customised feature (TFAad1H-c/2), which allows anadditional Pager transmit in Down link at 280 ± 5 MHz; it is suited to carry Flex or Pocsag signals.                                                       1 please refer to the specification sheets
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.9/157. TECHNICAL DETAILS7.1  OPTICAL CONNECTORSThe system uses FC/APC optical connectors; DO NOT ATTEMPT TO INSERT OTHERCONNECTORS, OTHERWISE SEVERE DAMAGE MAY OCCUR.The FC/APC connector is a high precision optical alignment device; it must be handled with care,to avoid scratches and other mechanical/optical damages that will impair or reduce the system’sperformance.Do not touch the connector’s tip, and clean it with proper tissues before inserting them into thesleeve. Do not leave connectors open. In case of better cleaning need, use only pure ethylalcohol.Sleeves can be cleaned by injecting pure gas under pressure.7.2  LOCAL INTERFACERefer to Table 1-2.Two types of local interfaces are provided: a local interface  composed of a 6 HE Subrack(TPR912), 6 plug in local interface modules and one or more RF combiner, depending on thesystem configuration or a standalone local interface.The plug in interface modules must be handled with care and only by expert people payingspecial attention to the optical fibre cables. In case you need to remove a local interface, youshould remove first the right adjacent module (whatever it is) or cover panel.Local interfaces cannot be placed close to each other; one 7te module is always required.IMPORTANT: prior to remove or insert any module make sure that power supply is off.7.2.1  6HE SUBRACK TPR912It can carry up to 6 Plug in local interfaces and the ancillary parts required by the systemconfiguration. The TPR912 includes the AC mains power supply, the required auxiliary circuitryand alarms.Alarm: a 9 pins sub D connector (male) on rear panel is used. See table 1 for functions andpinout. All alarms are relay-contacts, where the relays are excited when NOT ALARMED.If a local interface is not used, its related female connector on the backplane has to be closed bya replacing male connector, which is provided together with the rack.7.2.2  PLUG IN LOCAL INTERFACE MODULERefer to table 1.The downlink laser transmitter is internally connected to an optical splitter, which provides fouroutputs.The RF input port (SMA-female) must be connected to the BTS TX path, at the appropriate level(see specifications), eventually through the appropriate combiners configuration.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.10/15The uplink optical receivers RF outputs are combined to a single RF port (SMA-female) to beconnected to the BTS RX path, eventually through the appropriate combiners configuration; thisconnection might include an appropriate attenuator, not to desensitise or overload the BTSreceivers because of the noise floor and signals amplitude.The local signalling (front panel) includes a green LED  (PWR ON), plus status and/or alarmLEDs as follows:Laser transmitter A green LED lights when laser is biased (=).Each of two red LEDS lights when the corresponding laser's powerdecrease under limits and/or bias is not present (  ).A yellow LED lights when laser has shut-down command (OFF).Optical receivers A red LED lights if the input optical power is lower than -12dBm ( ).No adjustments are required at Local Interface Module.7.2.3  STANDALONE LOCAL INTERFACE UNITRefer to table 2.The downlink laser transmitter is internally connected to an optical splitter, which provides fouroutputs.The RF input port (SMA-female) must be connected to the BTS TX path, at the appropriate level(see specifications).The uplink optical receivers RF outputs are combined to a single RF port (SMA-female) to beconnected to the BTS RX path; this connection must include an appropriate attenuator, not todesensitise or overload the BTS receivers because of the noise floor and signals amplitude.The local signalling (front panel) includes a green LED  (PWR ON), plus status and/or alarmLEDs as follows:Laser transmitter A green LED lights when laser is biased (=)Each of two red LEDS lights when the corresponding laser's powerdecrease under limits and/or bias is not present ( ).A yellow LED lights when laser has shut-down command (OFF).Optical receivers A red LED lights if the input optical power is lower than -12dBm ( ).Alarm/controls : a 15 pins sub D connector (Female) on rear panel is used. See table 2 forfunctions and pinout. All alarm pins are O/C , low resistance to GND when NOT ALARMED.No adjustments are required at Local Interface.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.11/157.2.4 TFL BSIThe Base Station Interface module TFL-BSI provides the required level optimization between theBase Station Transmitters and the BriteCell system.It includes two independently variable attenuators in uplink and downlink.7.2.5 CROSSBAND COUPLER TLC2501The TLC2501 Crossband Coupler allows coupling uplink and downlink signals of services in thelower cellular band (800-1000 MHz) and in the upper cellular band (1700-2000 MHz).7.2.6  2-WAYS RF COMBINER TLC 2502/TFL-UDDThese devices are based on hybrid two ways couplers, plus resistive attenuators. They provideRF power splitting or combing for DL and UL paths.The Downlink RF input must be connected to the TX path at the appropriate level. The two RFoutputs must be connected to the RF inputs - SMA female of the local interface.The Uplink RF output must be connected to the BTS RX path.The two RF inputs must be connected to the RF output of the local interface.7.2.7  3-WAYS RF COMBINER TLC 2503These devices are based on hybrid three ways couplers, plus resistive attenuators. They providesRF power splitting or combing for DL and UL paths.The Downlink RF input must be connected to the TX path at the appropriate level. The three RFoutputs must be connected to the RF input - SMA female of the local interface.The Uplink RF output must be connected to the BTS RX path.The three RF inputs must be connected to the RF output of the local interface7.2.8  PAGER DL COMBINER TLC-DBThis device is a Dual -band  coupler for POCSAG pager injection at local interface. It combines a280 MHz POCSAG pager carrier on the downlink path at the appropriate level. It can be used inconjunction with TFA2xx1H-x/2 and TPA320, to provide indoor extended coverage of POCSAG.7.3  REMOTE RF OPTICAL TRANSCEIVERRefer to Table 3.This compact unit contains all the required functions. A stainless steel casing protects thehardware.Two RF ports and two optical connectors are placed on one side of the case.When inserting the optical connectors, take care that handling is smooth enough not to damagethe fibre; remove dust cap only immediately before making connections.A 50Ω termination must be present in the unused RF ports.An additional SMB-plug connector carries Pager signals and DC to the auxiliary active radiatorsTPA320, through the 3m connecting cable (only TFAad1H-c/2).The TFA ad1H -c(see datasheet "Ordering information - Part number") version is not providedwith the internal antenna. 2 RF-ports are supplied in order to connect 2 external antennas.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.12/15Two LEDs give local status information (LD1 red, LD2 green) as follows:LD2 lights when power supply is on.LD1 lights as resume alarm in case of no optical power at downlink input and/or in case of failure.The uplink laser is switched on only if downlink optical power is present. In case of any failure, thelaser is switched off.By this, the unit gives information on its operating status at local interface.7.3.1 PAGER REMOTE PANEL ACTIVE ANTENNA TPA320This device contains a power amplifier and a panel active antenna. It provides amplification andradiation of pager carrier at 280 MHz.The RF input (SMB-M) must be connected to the Paging RF port through a SMB-F/SMB-F cable.The power supply is provided through RF cable.7.3.2  MINIPANEL ANTENNA TPA302This antenna has been designed for radiation of pager carrier at 280 MHz. It is provided with a1-meter long N-female connectorised cable.7.3.3 FLAT PANEL MULTIBAND ANTENNA TPA 3020This antenna has been intended to include on a compact single element all the needed radiatorsof a multiple BriteCell system; it allows to minimise visual impact and installation effort.It carries on a single, compact radome the high gain radiators for GSM, DCS, PCS, VHF Paging.7.3.4  DOWNLINK AGCThe AGC function is provided in the downlink path, to maintain a constant link gain versus opticalloss, within the expected range (0 to 3dB).7.3.5  UPLINK GAIN SETTINGThe unit includes an RF attenuator, which has been provided to give flexibility toward coveragedesign. In case of closer mobiles forecast, the attenuator can reduce the uplink gain by 5 or 10dB. Refer as follows for S1 attenuator settings (bits 1,2,3,4):Bit 4 must be always on.Bit 1   2   3   4——————————————————————-Full gain: 0   0   1   15dB reduction: 0   1   0   110dB reduction: 1   0   0   1
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.13/157.3.6  POWER SUPPLYPower supply is connected via a factory-provided AC cable; the unit complies with ECsafety rules.Power supply is always on after the cable is connected to mains.Suited mains voltage is 84 to 264Vac, 50 or 60 Hz for TFA a51H-c (see datasheet "Orderinginformation - Part number").For TFA a11H-c version needs a 15÷28V AC/DC low voltage.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.14/158.  INSTALLATION HINTS8.1  INSTALLATION OF LOCAL INTERFACEInstallation of Local Interface is as per standard rules related to fixed base equipment.IMPORTANT: prior to remove or insert any module make sure that power supply is off8.2  INSTALLATION OF REMOTE RF OPTICAL TRANSCEIVERInstallation of Remote RF optical Transceivers must be carried effect taking care that the units areat least 2.5 m above the walking floor; while choosing their position, please remember thatmobiles should not come too close to the antenna.The unit is intended to be installed on walls, flat or orthogonal; an additional bracket is included toprovide this last possibility.The installation must provide the correct UP positioning, and cables must be laid so thataccidental damage is prevented.9. POWER LEVELSThe following table shows BriteCell downlink maximum input and output power as a function ofthe number of carriers being used.
Rel 00 08/04/98                         BriteCell Dual Band Operative and maintenance HandbookTekmar Sistemi S.r.l. keeps the right of any change or improvement without prior notice.  Pag.15/15NUMBEROFCARRIERSMaximumPOUT TFA/carrier (dBm)MaximumPIN TFL/carrier (dBm)Total Input Power(dBm)210,00 3,00 6,0137,67 0,67 5,4446,67 -0,33 5,6955,80 -1,20 5,7965,23 -1,77 6,0174,70 -2,30 6,1584,27 -2,73 6,3093,90 -3,10 6,4410 3,57 -3,43 6,5711 3,27 -3,73 6,6812 3,00 -4,00 6,7913 2,73 -4,27 6,8714 2,53 -4,47 6,9915 2,30 -4,70 7,0616 2,10 -4,90 7,1417 1,93 -5,07 7,2418 1,77 -5,23 7,3219 1,60 -5,40 7,3920 1,43 -5,57 7,44
TPR912ALARMSINTERFACE CONNECTOR(SUB D 9 pins male)PIN 1 NCPIN 2 COMMON RESUME ALARMS TXPIN 3 NCPIN 4 COMMON RESUME ALARMS RXPIN 5 NCPIN 6 CLOSED RESUME ALARMS TX OKPIN 7 OPEN RESUME ALARMS TX OKPIN 8 CLOSED RESUME ALARMS RX OKPIN 9 OPEN RESUME ALARMS RX OKTHE SUB D 9 PINS FEMALE IS NOT USEDTABLE1 TPR 912PLUG IN LOCAL INTERFACE MODULE
FRONT PANEL TFL X14HALARMS / CONTROLSINTERFACE CONNECTOR(SUB D 15 pins female)PIN  1GNDPIN 2TX RESUME ALARMPIN 3LASER SHUT-DOWNPIN 4RX RESUME ALARMPIN 5NCPIN 6RX 1 ALARMPIN 7RX 2 ALARMPIN 8RX 3 ALARMPIN 9TEMPERATURE ALARMPIN 10 POWER FAULT ALARMPIN 11 VAGC  RX1PIN 12 VAGC  RX2PIN 13 VAGC  RX3PIN 14 VAGC  RX4PIN 15 RX 4 ALARMTABLE 2 STANDALONE UNITLOCAL INTERFACE
TABLE 3 TFA ALL DUALBAND VERSIONSREMOTE RF OPTICAL TRANSCEIVER 2 RF-PORTS

Navigation menu