Andrew Wireless Innovations Group RPT-MR741 GSM channel selective repeater User Manual updatex41

Andrew Wireless Innovations Group GSM channel selective repeater updatex41

Contents

Antenna mounting information

Download: Andrew Wireless Innovations Group RPT-MR741 GSM channel selective repeater User Manual updatex41
Mirror Download [FCC.gov]Andrew Wireless Innovations Group RPT-MR741 GSM channel selective repeater User Manual updatex41
Document ID123026
Application IDz6BiyRgLazGzi9+oJlWxMw==
Document DescriptionAntenna mounting information
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize6.34kB (79259 bits)
Date Submitted2000-10-27 00:00:00
Date Available2000-11-02 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.02 for Windows
Document Lastmod0000-00-00 00:00:00
Document Titleupdatex41.PDF
Document CreatorMicrosoft Word
Document Author: Unknown

User’s manual for channel selective repeater MRx41
User’s manual for
channel selective repeater
MRx41
Manual updatex41.doc
Id.-No. 148092
Page 1
24-OCT-00
User’s manual for channel selective repeater MRx41
HEALTH AND SAFETY WARNINGS
Installer
Warning: Any over the air radiated use of this product is intended to be used
with either Roof Top (Building-mount) or Pole Mounted (Nonbuilding-mount) fixed Antennas.
Antenna installation must conform within the following guidelines to
meet FCC RF exposure limits, otherwise a environmental evaluation
is required if:
Broadband PCS (subpart E): Non-building-mounted antennas:
height above ground level to lowest point of antenna < 10m Radio
(Part 24) and total power of all channels > 2000 W ERP (3280 W
EIRP).
Building-mounted antennas: Total power of all channels > 2000 W
ERP (1640 W EIRP).
For any clarification, please refer to FCC rules, 47 CFR ch. I, part 1.1307
F Note:
F Note:
F Note:
F Note:
The electrical installation has to be performed in accordance with
the safety regulations of the local authorities. Due to safety reasons
the electrical installation must be performed by qualified personnel.
The cover of this unit should not be opened while power is applied.
Subsequent installation, commissioning and maintenance activities
that require the unit to be powered with the cover open shall only be
carried out by suitably qualified personnel.
The grounding of the Unit has to be performed by all means. A
grounding bolt is provided at the cabinet in order to connect the
earth bonding cable.
The Unit is heavy-weight. Make sure that a suitable mounting
surface is used. Only adequate manpower is allowed to handle the
system.
ESD precautions have to be observed! Before maintenance work use
the available grounding system to connect ESD protection
measures.
Manual updatex41.doc
Id.-No. 148092
Page 10
24-Oct-00
User’s manual for channel selective repeater MRx41
1 INTRODUCTION
1.1 Intended purpose
Cellular telephone systems transmit signals in two directions between base stations and
mobile telephones within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, a repeater is used to
extend transmission range. In the downlink path the repeater picks up the signal from a
donor antenna of an existing cell, amplifies and re-transmits it into the desired dark spot.
In the uplink direction the repeater receives signals from mobile stations present in its
coverage area and re-transmits them to the corresponding base station.
The over the air radiated use of this repeater is intended to be used with either Roof Top
or Pole Mounted Antennas. To provide coverage in a indoor application one must mount
the antennas on or outside the building structure that is occupied. This must be done in
a matter that conforms to the FCC RF exposure ( See health and Saftey section of this
manual).
1.2 About the MRx41
The repeater MRx41 is a channel selective amplifier, which bi-directionally amplifies
signals between multiple mobiles and a single base station in the GSM900, GSM1800,
and PCS1900 mobile telephone system. It can provide highly selective amplification of
upto 8 channels, thus enabling radio coverage in regions where satisfactory quality of
communication is disabled. The basic unit is capable of 2 channels.
The MRx41 can be set-up locally or remotely. A PCMCIA slot for modem operation is an
available option. The repeater has a large number of functions that can be monitored
and changed by the operators via a terminal emulation program or the MIKOM OMC
software platform. An easy to understand and simple to learn communication language
is available to help the operator query status reports from the repeater or to change
settings
F Note:
It is not possible to combine PCS 1900 MRx41 units / modules with
other MRx41 units / modules.
Manual updatex41.doc
Id.-No. 148092
Page 13
24-Oct-00

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 3
Creator                         : Microsoft Word
Create Date                     : Friday, October 27, 2000 11:14:36 AM
Title                           : updatex41.PDF
Author                          : Unknown
Producer                        : Acrobat PDFWriter 3.02 for Windows
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BCR-RPT-MR741

Navigation menu