PRODUCT SPeCifiCaTiOnmoved simultaneously from a cluster of base stations to a remote location over the same fiber.The ION optical distribution system is a cost-effective coverage solution for dense urban areas, tunnels, subway, airports, convention centers, high-rise buildings and other locations where physical structures increase path loss. It has been specifically designed to reduce zoning problems and to pro-vide homogeneous coverage. The compact, mechanical design is specifi-cally architected to mount inside of poles or along side structures in such a way that it has a minimal visual impact.The ION-M17EHP/19P is available in a multi-band configuration support-ing 1900 MHz and 1700/2100 MHz in parallel and with extension option 700 MHz additionally. It has been specifically tested and optimized for GSM, CDMA2000, WCDMA, and LTE signals. Furthermore it is pro-visioned for future modulation schemes and frequency bands.The ION is easily set-up and super-vised via a graphical user interface (GUI). Remote units can be commis-sioned through the use of built-in test equipment. An auto-levelling func-tion compensates for the optical link PRODUCT SPECIFICATIONION® is the unified platform for all conceivable optical distribution scenarios.The ION optical distribution system leads the industry in flexibility while minimizing the overall deployment cost.loss making installation easy and quick. The entire system as well as complete network of systems can be managed remotely most efficiently by Commscope`s A.I.M.O.S, which includes alarm monitoring, task auto-mation, inventory management and many more features. Should a sophis-ticated interface not be re-quired, the master unit can be directly connected to the alarm interface of a base station via relay alarming.• Multi-band, multi-operator support• Reduced visual impact form factor• Efficient, high power amplifier• Single fiber for multiple bands  and multiple remotes• Comprehensive operations and management system for configura- tion and alarming• OMC with SNMP according to X.733 standard• With reference to 3GPP TS25.143/  TS25.106/ TS36.143/   TS36.106 and 3GPP2C.S0051-0• Easy installation and commissioningCommScope’s ION-M17EHP/19P is a multi-band multi-operator remote unit. It is used in conjunction with a master unit in the ION optical distribu-tion system. This system transports mul-tiple frequency bands simultaneously (1900 MHz and 1700/2100 MHz), providing a cost-effective solution for distributing capacity from one or more base stations. By supporting the entire AWS-3 spectrum, faster and more reli-able wireless service is ensured and network quality can be improved.The ION-M17EHP/19P transports sig-nals on the RF layer in a very inexpen-sive manner. This means that multiple operators and multiple technologies are ION-M17EHP/19PMulti-band, Multi-operator Remote Optical SystemSupport of AWS-3 SpectrumION® Series
SPECIFICATIONSElectricalMains power, Vac   ................nominal..............100 to 240   ................operating .............85 to 264Vdc mails power not possible.Power consumption, W   ................max. temp., fully loaded.....770   ................room temp., idle .........400Optical LinkConnectors..................................E2000/APC 8° Optical return loss, dB ......................45 min.Fiber type,mm ..............................Single mode E9/125 Optical link budget, dB .....................0 to 10Input power  @ OTRx master side, dBm   ................1900 MHz ............+2.5 composite   ................1700/2100 MHz.........+5.5 composite   ................700 MHz .............+3 compositeMinimum BTS Input power, dBm..............   ................1900 MHz ............-19.5   ................1700/2100 MHz.........-16.5   ................700 MHz .............-19 Additional DL gain (22 dB) available in case of low power BTSRF InterfaceMaster Unit Number of connectors   ................1900 MHz ............4   ................1700/2100 MHz.........4   ................700 MHz .............4System optimized for BTS power, dBm   ..................................33   ..................................43Antenna Port of Remote Unit Connector  ................ . . . . . . . . . . . . . . . . . N FemaleOutput power............. . . . . . . . . . . . . . . . . . See band specification Return loss, dB ............ . . . . . . . . . . . . . . . . . 15 typical1700/2100 MHz (AWS)Frequency range, MHz   ................Uplink ..............1710 to 1780   ................Downlink .............2110 to 2180RF output power per carrier *, dBmNumber of Carriers  1  2   4   8CDMA   45.5 42.5 39.5 36.5UMTS   45.5 42.5 39.5 36.5 LTE   45.5 42.5**** 39.5 36.5Spurious emission ........ . . . . . . . . . . . . . . . . . <-13 dBm / 1 MHzDL output tolerance over frequency, dB  ........±1DL output tolerance over temperature, dB .......±0.5**UL Input ICP3, dBm   ................ICP3 optimized ..........-12 min.   ................Noise figure optimized ......-18 min.UL Noise figure, dB   ................ICP3 optimized ..........8   ..................................11 max.   ................Noise figure optimized ......4.5   ..................................6 max.1900 MHzFrequency range, MHz   ................Uplink ..............1850 to 1915   ................Downlink ............1930 to 1995RF output power per carrier *, dBmNumber of Carriers  1  2   4   8GSM   42.5 39.5 36.5 33.5 CDMA   42.5 39.5 36.5 33.5UMTS   42.5 39.5 36.5 33.5 LTE   42.5 39.5**** 36.5 33.5Spurious emission......... . . . . . . . . . . . . . . . . . <-13 dBm / 1 MHzDL output tolerance over frequency, dB ........±1DL output tolerance over temperature, dB .......±0.5**UL Input ICP3, dBm   ................ICP3 optimized..........-12 min.   ................Noise figure optimized......-18 min.UL Noise figure, dB   ................ICP3 optimized ..........8   ..................................11 max.   ................Noise figure optimized ......4.5   ..................................6 max.System Supervision and ControlCommands .................................RF on/off     ..........................................External control portsAlarms   ..................................Summary     ..................................Power supply   ..................................Optical UL and DL failure   ..................................TemperatureSupervision .................................Output power on a per-   ..........................................channel and per-   ..........................................band basis (optional)Mechanical***Height, width, depth mm (in) ................831 x 156  x 147   ..........................................(32.7 x 6.1 x 5.8)Weight, kg (Ib) ........... . . . . . . . . . . . . . . . . . 20 (44)EnvironmentalOperating temperature range...............-33° C to +50° CIngress protection ......RF part .............IP67   ................Fan part .............IP55Minimum SW Requirements for Basic SupportION-M SW V7.0.1Ordering InformationION-M17EHP/19P .........................7714210 Depending on the selected options and the configuration the ordering material number contains an identifying suffix.Extension Unit OptionsION-M7P EU ...............................7601170 Other Extension Units possible on request*   PAR 7.5 dB @ 0.1 % **   With active cooling ***   Spacing required 40 mm (1.58 in) around unit **** 2 dB reduction of Pout @ carrier bandwidth < 5 MHz  All figures are typical values unless otherwise stated.ION-M17EHP/19P - Product Specification
SPECIFICATIONSION-M17EHP/19P Remote Unit Cabinet DrawingION-M17EHP/19P - Product Specification700 MHz Extension Unit ION-M7P EUFrequency range, MHz  ................Uplink ..............698 to 716   ..........................................776 to 787    ................Downlink ............728 to 757RF output power per carrier *, dBmNumber of Carriers  1  2   4   8 LTE   43 40*** 37 34Spurious emission......... . . . . . . . . . . . . . . . . . <-13 dBm / 1 MHzDL output tolerance over frequency, dB ........±1DL output tolerance over temperature, dB .......±0.5**UL Input ICP3, dBm   ................ICP3 optimized..........-11 min.   ................Noise figure optimized......-18 min.UL Noise figure, dB   ................ICP3 optimized..........7   ..................................10 max.   ................Noise figure optimized  .....4.5   ..................................6 max.*   Applicable to single modulation mode only **   With active cooling ***  2 dB reduction of Pout @ carrier bandwidth < 5 MHzAll figures are typical values unless otherwise stated.UL-AmpDuplexerUnitPowerAmplifierNConnectorfrom /toMobile StationControllerRS485DPX700 MHz2ExtensionInterfaceION-M7P Extension Unit
SPECIFICATIONSwww.commscope.comVisit our Web site or contact your local Commscope representative for more information. © 2015 Commscope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of Commscope, Inc.  This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Commscope products or services.CommScope reserves the right to change all hardware and software characteristics without notice.ION-M17EHP/19P Remote Unit Design PrincipleDesign Principle ION SystemION-M17EHP/19P - Product SpecificationBulletin PA-109873-EN.GB (11/15)WARNING:  This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS.  You MUST have an FCC LICENSE or express consent of an FCC LICENSE to operate this device.  Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $ 100,000 for each continuing violation.Gain DL Gain ULICP3  optimizedNF  optimizedICP3  optimizedNF  optimized700 MHz 40 dB 40 dB 40 dB 47 dBPCS1900 40 dB 40 dB 39 dB 46 dBAWS1700/2100 40 dB 40 dB 40 dB 47 dB