Andrew Wireless System NCM843 Repeater for Cellular Networks User Manual Additional information on SM2009

Andrew Wireless System Repeater for Cellular Networks Additional information on SM2009

User Manual

Download: Andrew Wireless System NCM843 Repeater for Cellular Networks User Manual Additional information on SM2009
Mirror Download [FCC.gov]Andrew Wireless System NCM843 Repeater for Cellular Networks User Manual Additional information on SM2009
Document ID1271485
Application ID2YVXBYI1n+3WlDEhw29H2Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize168.06kB (2100775 bits)
Date Submitted2010-04-23 00:00:00
Date Available2010-04-23 00:00:00
Creation Date2010-02-05 09:22:58
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2010-02-05 09:29:49
Document TitleAdditional information on SM2009
Document CreatorAcrobat PDFMaker 8.1 für Word
Document Author: Raissa Panlilio

Repeaters
Node M and Node C
Network Elements
User's Manual
M0121A4A
User’s Manual for Node M and Node C
Network Elements
© Copyright 2010 CommScope, Inc.
All rights reserved.
Andrew Solutions is a trademark of CommScope, Inc.
All information contained in this manual has been revised thoroughly. Yet Andrew
Solutions accepts no liability for any omissions or faults.
Andrew Solutions reserves the right to change all hard- and software characteristics
without notice.
Names of products mentioned herein are used for identification purposes only and
may be trademarks and / or registered trademarks of their respective companies.
No parts of this publication may be reproduced, stored in a retrieval system,
transmitted in any form or by any means, electronical, mechanical photocopying,
recording or otherwise, without prior written permission of the publisher.
Andrew Wireless Systems GmbH, 05-February -2010
Page 2
M0121A4A.doc
TABLE OF CONTENTS
1. GENERAL
1.1.
USED ABBREVIATIONS
1.2.
HEALTH AND SAFETY WARNINGS
1.3.
ABOUT ANDREW SOLUTIONS
11
1.4.
INTERNATIONAL CONTACT ADDRESSES FOR WIG CUSTOMER SUPPORT
12
2. INTRODUCTION
15
2.1.
PURPOSE
15
2.2.
THE NODE M AND NODE C (NODE M/C) NETWORK ELEMENT
15
2.3.
QUICK START CHECKLIST
16
3. CONNECTION SETUP
19
3.1.
19
SETTING UP A LOCAL / LAN CONNECTION FROM LAPTOP / PC
3.2.
SETTING UP NODE M/C REPEATER TO RUN AS A LAN ELEMENT
3.2.1.
Prerequisites
3.2.2.
Procedure
20
20
20
3.3.
21
SETTING UP A REMOTE CONNECTION
4. INSTALLATION
23
4.1.
MECHANICAL INSTALLATION
4.1.1.
General
4.1.2.
Wall Mounting Procedure
4.1.3.
Pole Mounting Procedure
23
23
24
26
4.2.
ELECTRICAL INSTALLATION
4.2.1.
General
4.2.2.
Grounding
4.2.3.
Power Connection
4.2.4.
Connection of the Antenna Cables
4.2.5.
Opening the Cabinet - Mains Power Switch
29
29
30
31
33
34
Page 3
User’s Manual for Node M and Node C
Network Elements
5. FUNCTIONAL DESCRIPTION
37
5.1.
37
DIGITAL ARCHITECTURE
5.2.
FEATURES
5.2.1.
Filters Node M
5.2.2.
Filters Node C
5.2.3.
Digital ICE (Digital Interference Cancellation Equipment)
5.2.4.
VSWR (Voltage Standing Wave Ratio)
5.2.5.
RSSI (Receive Signal Strength Indication)
5.2.6.
Alarm Forwarding
5.2.7.
Downlink Final Amplifier
5.2.8.
Power Supply Unit
5.2.9.
Modems
5.2.10.
Digital Channel Module (DCM)
5.2.11.
External Alarm Controller - EAC-Board
5.2.12.
Battery Pack - Battery On/Off
5.2.13.
UL and DL Duplexer
39
39
39
40
40
41
41
42
44
45
48
49
55
57
6. MAINTENANCE AND REPLACEMENT
59
7. ILLUSTRATIONS
59
7.1.
CABINET DRAWING
59
7.2.
LAYOUT OF THE NODE M/C 843
60
8. INDEX
Page 4
61
M0121A4A.doc
FIGURES AND TABLES
figure 3-1 Ethernet connector RJ45
figure 3-2 Pin connection
figure 3-3 Cable gland position
figure 4-1 Positions of drilling holes
figure 4-2 Wall mounting procedure
figure 4-3 Pole mounted units
figure 4-4 Back-to-back pole mounting
figure 4-5 Grounding bolt
figure 4-6 Power supply plug
figure 4-7 Mains connector of a Node M, exemplary
figure 4-8 Mains connector and antenna connections of a Node C, exemplary
figure 4-9 Front view of antenna connections from Node C, exemplary
figure 4-10 Front and top cover screws
figure 4-11 Position of mains power switch
figure 5-1 Configuration of a network element
figure 5-2 RF path of a Node C 843, exemplary
figure 5-3 Node M/C x37 MCPA DL final amplifier
figure 5-4 Node M 2143 and Node M 1943 MCPA DL final amplifier
figure 5-5 Node M/C 843 DL final amplifier
figure 5-6 Power supply, Node M/C x37
figure 5-7 Power supply, Node M/C x43
figure 5-8 Modem MC35
figure 5-9 Redwing modem (CDMA)
figure 5-10 Modem AnyDATA iPORT EMIII Dual / EM IV Dual
figure 5-11 Modem Raven XT
figure 5-12 Modem MTCBA-C-N9
figure 5-13 Cable from modem to donor duplexer
figure 5-14 Cable from modem to external modem antenna port; Node M
figure 5-15 Digital channel module, DL part
figure 5-16 Digital channel module, UL part
figure 5-17 EAC-board, installed
figure 5-18 Function of LEDs on the EAC-board
figure 5-19 Pin assignment
19
20
20
24
25
26
27
30
31
31
31
33
34
35
37
38
42
42
43
44
44
45
45
46
46
46
47
47
48
48
49
51
52
Page 5
User’s Manual for Node M and Node C
Network Elements
figure 5-20 External alarm clamps, installed
figure 5-21 Configuration of external alarm clamps
figure 5-22 External cable glands
figure 5-23 Summary alarm relay
figure 5-24 Relay contacts, alarm condition
figure 5-25 Battery pack, exemplary
figure 5-26 Battery pack installed and its connection to DCM
figure 5-27 Position of the battery disconnect button on the EAC-board
figure 5-28 Duplexer, UL IN
figure 5-29 Duplexer, DL IN
figure 5-30 Duplexers installed
figure 5-31 Duplexers installed, ceramic duplexer DL IN
figure 7-1 Cabinet of a Node M, respective Node C, exemplary
figure 7-2 Layout of the Node M/C 843, exemplary
52
53
53
54
54
55
55
56
57
57
57
58
59
60
table 1-1 List of international contact addresses....................................................... 13
table 4-1 Required length of thread-bolts ................................................................. 26
table 4-2 Components of pole mounting kit .............................................................. 27
table 4-3 Pin assignment of mains connector ........................................................... 32
table 5-1 Pin assignment of relay contacts ............................................................... 54
Page 6
M0121A4A.doc
1 General
1. GENERAL
1.1. USED ABBREVIATIONS
A/D
AGC
ALC
ARFCN
BCCH
BTS
CDMA
D/A
DAS
DCM
DHCP
D-ICE
DL
DSP
EAC
EDGE
ESD
ETS
ETSI
FCC
FRU
GPRS
GSM
HID
HSN
I2C Bus
ICE
ID No
LAN
LED
LMT
LNA
LO
MAIO
MCPA
Ncm
NSB
OFDM
OMC
PA
PAMR
PPP
PSTN
RF
Analogue to Digital Converter
Automatic Gain Control
Automatic Level Control
Absolute Radio Frequency Channel Number
Broadcast Control Channel
Base Transceiver Station
Code Division Multiple Access
Digital to Analogue Converter
Distributed Antenna System
Digital Channel Module
Dynamic Host Configuration Protocol
Digital Interference Cancellation Equipment
Downlink
Digital Signal Processor
External Alarm Controller
Enhanced Data Rates for GSM Evolution
Electrostatic Discharge
European Telecommunication Standard
European Telecommunication Standards Institute
Federal Communications Commission
Field Replaceable Unit
General Packet Radio Service
Global System for Mobile Communication
Hardware Inventory Data
Hopping Sequence Number
Inter Integrated Circuit Bus (Philips)
Interference Cancellation Equipment
Identification Number
Local Area Network
Light Emitting Diode
Local Maintenance Terminal
Low Noise Amplifier
Local Oscillator
Mobile Allocation Index Offset
Multi Carrier Power Amplifier
Newton centimeter
Network Supervision Box
Orthogonal Frequency Division Multiplex
Operation and Maintenance Centre
Power Amplifier
Public Access Mobile Radio
Point-to-Point Protocol
Public Switched Telephone Network
Radio Frequency
Page 7
User’s Manual for Node M and Node C
Network Elements
RLP
RSCP
RSSI
RTC
RX
SCPA
SDA
SMS
SNMP
TS
UE
UL
UMTS
UPS
UTC
UTRA
VCO
VSWR
WCDMA
Page 8
Radio Link Protocol
Received Signal Code Power
Receive Signal Strength Indication
Real Time Clock
Receiver
Single Carrier Power Amplifier
Serial Data
Short Message Service
Simple Network Management Protocol
Transmitter
User Equipment
Uplink
Universal Mobile Telecommunication System
Uninterruptible Power Supply
Universal Time Coordinate
UMTS terrestrial radio access
Voltage Controlled Oscillator
Voltage Standing Wave Ratio
Wide-band Code Division Multiple Access
M0121A4A.doc
1 General
1.2. HEALTH AND SAFETY WARNINGS
1. Only suitably qualified people are allowed to work on this unit and only after
becoming familiar with all safety notices, installation, operation and maintenance
procedures contained in this manual.
2. Read and obey all the warning labels attached to the unit. Make sure that the
warning labels are kept in a legible condition and replace any missing or
damaged labels.
3. Obey all general and regional installation and safety regulations relating to work
on high voltage installations, as well as regulations covering correct use of tools
and personal protective equipment.
4. Keep operating instructions within easy reach and make them available to all
users.
5. It is the responsibility of the network provider to implement prevention measures
to avoid health hazards which may be associated to radiation from the antenna(s)
connected to the unit.
6. IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements,
the following antenna installation and device operating configurations must be
satisfied: A separation distance of at least 400 cm must be maintained between
the antenna of this device and all persons. RF exposure compliance may need to
be addressed at the time of licensing, as required by the responsible FCC
Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Maximum
permissible antenna gain is 17 dBi.
7. Make sure, access is restricted to qualified personnel.
8. Only licence holders for the respective frequency range are allowed to operate
this unit.
9. Use this equipment only for the purpose specified by the manufacturer. Do not
carry out any modifications or fit any spare parts which are not sold or
recommended by the manufacturer. This could cause fires, electric shock or other
injuries.
10. Due to power dissipation, the network element may reach a very high
temperature. Do not operate this equipment on or close to flammable materials.
11. Before opening the unit, disconnect mains.
12. ESD precautions must be observed! Before commencing maintenance work, use
the available grounding system to connect ESD protection measures.
Page 9
User’s Manual for Node M and Node C
Network Elements
13. This unit complies with European standard EN60950.
14. Make sure the network element settings are according to the intended use (see
also product information of manufacturer) and regulatory requirements are met.
15. Although the network element is internally protected against overvoltage, it is
strongly recommended to earth the antenna cables close to the network
element’s antenna connectors for protection against atmospheric discharge.
Page 10
M0121A4A.doc
1 General
1.3. ABOUT ANDREW SOLUTIONS
Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading
manufacturer of coverage equipment for mobile radio networks, specializing in low
cost, high performance, RF and optical repeaters. Our optical distributed networks
and RF repeater systems provide coverage for every application: outdoor use, indoor
installations, tunnels, subways and many more.
Andrew Wireless Systems GmbH belongs to the Wireless Innovations Group (WIG).
Being a part of Andrew Solutions, WIG has unparalleled experience in providing RF
coverage and capacity solution for wireless networks in both indoor and outdoor
environment.
Andrew Solutions, a CommScope Company, is the foremost supplier of one-stop,
end-to-end radio frequency (RF) solutions. Our products are complete solutions for
wireless infrastructure from top-of-the-tower base station antennas to cable systems
and cabinets, RF site solutions, signal distribution, and network optimization.
Andrew Solutions has global engineering and manufacturing facilities. In addition, it
maintains field engineering offices throughout the world.
We operate a quality management system in compliance with the requirements of
ISO 9001. All equipment is manufactured using highly reliable material. In order to
ensure constant first-rate quality of the products, comprehensive quality monitoring is
conducted at all fabrication stages. Finished products leave the factory only after a
thorough final acceptance test, accompanied by a test certificate guaranteeing
optimal operation.
The declaration of conformity for the product is available upon request from the local
sales offices or from Andrew Solutions directly.
To make the utmost from this unit, we recommend you carefully read the instructions
in this manual and commission the unit only according to these instructions.
For technical assistance and support, contact the local office or Andrew Solutions
directly at one of the following addresses listed in the next chapter.
Page 11
User’s Manual for Node M and Node C
Network Elements
1.4. INTERNATIONAL
SUPPORT
CONTACT
ADDRESSES
FOR
WIG
CUSTOMER
Wireless Innovations Group (WIG)
Americas:
Canada
United States
Andrew Solutions Canada
Andrew Solutions,
Andrew LLC, A CommScope Company
Mail
620 North Greenfield Parkway
Garner, NC 27529
U.S.A.
Mail
620 North Greenfield Parkway
Garner, NC 27529
U.S.A.
Phone
+1-905-878-3457 (Office)
+1 416-721-5058 (Mobile)
Phone
+1-888-297-6433
Fax
+1-905-878-3297
Fax
+1-919-329-8950
E-mail
Peter.Masih@andrew.com
WIsupport.us@andrew.com
E-mail
WIsupport.us@andrew.com
Brazil & South America
Mexico, Central America &
Caribbean region
Andrew Solutions,
A CommScope Company
Andrew Solutions Mexico
Mail
Av. Com. Camilo Julio 1256
Predio B
Zonal Industrial CP 597
Sorocaba SP 18086-000
Brazil
Mail
Monte Elbruz 124-402A
Col. Palmas Polanco 11560
Mexico, D.F.
Mexico
Phone
+ 55-15-9104-7722
Phone
+ 52-55-1346-1900 (Office)
+52-1-55-5419-5260 (Mobile)
Fax
+ 55-15-2102-4001
Fax
+52-55-1346-1901
E-mail
WIsupport@andrew.com
E-mail
WIsupport@andrew.com
APAC Countries:
China
Andrew Solutions Hong Kong
Australia
Andrew Corporation (Australia)
LLC Pty Ltd.
Mail
Room 915
Chevalier Commercial Centre
8 Wang Hoi Rd
Kowloon Bay SAR
Hong Kong
Mail
Unit 1
153 Barry Road
Campbellfield
VIC 3061
Australia
Phone
+852-310-661-00
Phone
+613-9300-7969
Fax
+852-2751-7800
Fax
+613-9357-9110
E-mail
WISupport.china@andrew.com
E-mail
WIsupport.australia@andrew.com
Page 12
M0121A4A.doc
1 General
Europe:
United Kingdom
France
Andrew Solutions UK Ltd
Andrew Solutions France
Mail
Unit 15, Ilex House
Mulberry Business Park
Fishponds Road
Wokingham Berkshire
RG41 2GY
England
Mail
28, Rue Fresnel
Z.A Pariwest
BP 182
78313 Coignières Cedex
France
Phone
+44-1189-366-792
Phone
+33 1 30 05 45 50
Fax
+44-1189-366-773
Fax
+33 1 34 61 13 74
E-mail
WIsupport.uk@andrew.com
E-mail
WIsupport@andrew.com
Germany
Czech Republic
Andrew Wireless Systems GmbH
Andrew Solutions Czech Republic
C-Com, spol. s r.o
Mail
Industriering 10
86675 Buchdorf
Germany
Mail
U Moruší 888
53006 Pardubice
Czech Republic
Phone
+49-9099-69-0
Phone
+420-464-6280-80
Fax
+49-9099-69-930
Fax
+420-464-6280-94
E-mail
WIsupport@andrew.com
E-mail
WIsupport@andrew.com
Austria
Switzerland
Andrew Wireless Systems (Austria)
GmbH
Andrew Wireless Systems AG
Mail
Weglgasse 10
Wien-Schwechat 2320
Austria
Mail
Tiergartenweg 1
CH-4710 Balsthal
Switzerland
Phone
+43-1706-39-99-10
Phone
+41-62-386-1260
Fax
+43-1706-39-99-9
Fax
+41-62-386-1261
E-mail
WIsupport.austria@andrew.com
E-mail
support.ch@andrew.com
Italy
Spain & Portugal
Andrew Wireless Systems S.r.l., Faenza,
Italy
Andrew Solutions España S.A.
Mail
Via de Crescenzi 40
Faenza 48018
Italy
Mail
C/ Salvatierra, 5 - 3a pt.
28034 Madrid
Spain
Phone
+39-0546-697111
Phone
+34-91-745-20 40
Fax
+39-0546-682768
Fax
+34-91-564-29 85
E-mail
WIsupport.italia@andrew.com
E-mail
WIsupport.iberia@andrew.com
table 1-1 List of international contact addresses
Page 13
User’s Manual for Node M and Node C
Network Elements
For your notes:
Page 14
M0121A4A.doc
2 Introduction
2. INTRODUCTION
2.1.
PURPOSE
Wireless communication systems provide a two-way information transfer (voice and
data) between a base station and multiple mobiles within a given area.
Environmental variables such as physical structures both man-made (buildings) and
natural (mountains) attenuate signals in the transmission path, which reduce the
transport signal’s strength. This attenuation leads to a reduction in quality and data
rate and eventually prohibits the system’s use entirely. The Node M and Node C are
specifically designed to extend coverage, enhance quality, and increase air-interface
capacity.
In the downlink (DL), the Node M and Node C picks up signals coming from the base
station, filters them, amplifies them, and retransmits them to the mobile. In the uplink
(UL), it picks up signals from the mobile, filters them, amplifies them, and retransmits
them to the base station. The Node M and Node C constantly monitors the quality of
the signals passing through it, while simultaneously electronically decreasing
isolation requirements.
2.2.
THE NODE M AND NODE C (NODE M/C) NETWORK ELEMENT
Node M and Node C are primary network elements, capable of enhancing up to 20
MHz of continuous spectrum. Their primary function is to increase the signal strength
between multiple mobiles and a base station in areas where basic voice or highspeed data transmission is not available. They may be used for basic coverage,
signal reinforcement, and cell shaping, which can increase a network’s coverage
area, data rate, and capacity.
The Node M is a dedicated UMTS device, but the Node C operates with CDMA
technology. However, several enhancers operating at different frequencies and
technologies may share the same hardware (cables and antennas) via a crossband
coupler.
The Node M or Node C may be set-up locally or remotely. A circuit switch or packet
data modem may be connected to an integrated controller. This provides the network
management system with on-demand, alarm generated, or heartbeat monitoring via
the always-connected packet features. The Node M and Node C have features and
functions that may be monitored and changed by the operators via a web-based
browser remotely or locally, or via the SNMP based OMC software platform. The
graphical interfaces of Node M and Node C provide a setup menu including a setup
wizard which allows both setup and monitoring capability without any equipment
required apart from a laptop or PC.
The Node M and Node C network elements are self-diagnosing, self-adaptive, and
virtually maintenance-free.
In the following, the expression Node M/C stands for Node M and Node C.
Page 15
User’s Manual for Node M and Node C
Network Elements
2.3.
QUICK START CHECKLIST
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
Setting up the Node M/C is quick and easy. The following step-by-step
procedure provides a quick overview for a correct setup and optimization.
a. Required Equipment
Node M or Node C
donor antenna
coverage antenna(s) or DAS
coaxial feeder cable
connectors (RF, mains)
laptop (Win XP or Win 2000) with connection and mains cable
standard Ethernet cable (CAT5) (see chapter 3 Connection Setup)
b. Required Information
Make sure to have the following information at hand:
important on-site conditions (e.g. BTS location, mains supply, etc.)
channels to be enhanced/ amplified
pilot power to total power ratio
data of mandatory fields of Connectivity and Upload page see user's
manual for Node software.
c. Procedure
1. Install the donor (linear polarized recommended) and coverage antennas.
2. Install the feeder cable from the Node M/C to the antennas.
3. Install the Node M/C (see chapter 4.1 Mechanical Installation)
) Note:
Take care to ground the unit correctly as instructed in chapter 4.2.2
Grounding.
4. Connect power and the antenna feeder cables to the Node M/C.
5. Open the Node M/C as described in chapter 4.2.5 Opening the Cabinet Mains Power Switch.
6. Setup the connection computer (see chapter 3 Connection Setup and software
manual).
Page 16
M0121A4A.doc
2 Introduction
7. Login to the unit and follow the installation wizard option for easy installation.
a.
Optimize the donor antenna performance (see software manual).
b.
To select the channels for enhancement, choose between the
“Measurement Assisted Channel Assignment” or “Unassisted
Channel Assignment” from the Setup Wizard page (see software
manual).
c.
Enter the pilot power to total power ratio of the donor Base Station.
d.
Enter the desired output power in the downlink.
e.
Enter the relative uplink gain and click the “Program” button.
f.
Select the “Connectivity and Upload” button, to setup the modem (if
applicable) and to enter data in the other user fields (see software
manual).
g.
Select the “Technician Setup” button (see software manual), to
change additional system settings, e.g. ICE, H.R. Filter, Diversity;
the “Technician Setup” is also accessible from the home page.
8. The Node M/C setup is complete.
9. Open the “Save Configuration to Laptop” menu for record keeping purposes.
10. Unplug the computer, close the Node M/C and tighten all screws.
) Note:
To do a power cycle, disconnect the battery backup by pushing the
battery disconnect button on the EAC-board; see chapter
5.2.12 Battery Pack - Battery On/Off.
Page 17
User’s Manual for Node M and Node C
Network Elements
For your notes:
Page 18
M0121A4A.doc
3 Connection Setup
3. CONNECTION SETUP
3.1.
SETTING UP A LOCAL / LAN CONNECTION FROM LAPTOP / PC
figure 3-1 Ethernet connector RJ45
Ethernet connector - LEDs
After the connection is made properly, the red and green LEDs near the Node C
network connector will flash.
No
Colour Explanation
LED illuminates when a packet is transmitted by the DCM2 DL
Yellow
module.
Green LED illuminates when a packet is received by the DCM2 DL module.
A standard CAT5 Ethernet cable is supplied to set up a local connection. Open the
Node and plug the cable in the Ethernet connector RJ45 of the EAC-board.
To setup a LAN connection follow the description in the next chapter. A cable is not
provided.
Page 19
User’s Manual for Node M and Node C
Network Elements
3.2.
SETTING UP NODE M/C REPEATER TO RUN AS A LAN ELEMENT
3.2.1. Prerequisites
Use the Local Area Network (LAN) mode to activate DHCP clients or to assign a
static IP address to the Node M/C.
) Note:
Before it is possible to configure the LAN settings alarm connectors
7 and 8 must be connected in order to activate External Alarm 1,
figure 3-2 Pin connection.
A local connection via laptop or PC cannot be setup as long as alarm connectors 7
and 8 are connected.
) Note:
In the software, LAN Information settings will be activated, if the
main connectivity is set to LAN. Please refer to the software
manual.
For the connection of the Node to the LAN network please use the same type /
category of Ethernet cable as for the connection of the computer to the LAN network.
3.2.2. Procedure
1. Switch off repeater and connect Pin 7 and Pin 8 of the External Alarm connector.
Pin
10
12
14
16
n.c.
GROUND
GROUND
GROUND
PSTN_1_EXTERNAL
PSTN_2_EXTERNAL
GROUND
GROUND
Pin
11
13
15
16
n.c.
EXT_ALARM_3
EXT_ALARM_2
EXT_ALARM_1
PSTN_1_INTERNAL
PSTN_2_INTERNAL
SUMMARY ALARM, LED GREEN
SUMMARY ALARM, LED RED
15
figure 3-2 Pin connection
2. Switch on repeater
3. Put an Ethernet CAT5 cable
(recommended cable diameter is
4 - 6 mm) through one of the PG7
cable glands into the Node.
figure 3-3 Cable gland position
Page 20
M0121A4A.doc
3 Connection Setup
4. Crimp the RJ45 connector and connect it to the RJ45 jack of the EAC board. This
is the same connector as for a local connection. See figure 3-1 Ethernet
connector RJ45 on page 19).
5. Fasten the cable glands properly to ensure waterproofness.
6. Configure Main connectivity on the Connectivity page to be LAN so that the
LAN section on the Connectivity page will be activated (for details see software
manual, chapter LAN Information).
7. To enable the DHCP client, set the DHCP check mark. To enter a static IP,
DHCP must be disabled and the IP entry fields will become activated, indicated
by white colour.
Entry fields to set static IP
(white = active; grey = deactivated)
For further details on IP address setting see software manual.
8. Press the Submit button.
9. Connect the Node via the CAT5 cable from Step 3 to the (customer) LAN
network and the Node will get a LAN IP. For more information on LAN IP see
software manual.
3.3.
SETTING UP A REMOTE CONNECTION
Use the manual 'Network and Dial-Up Connections - Setup' to establish a remote
connection.
Using the remote connection, the operator can monitor and control the Node M using
the Web browser interface remotely.
In addition, the remote connection may be used for:
An OMC-type software platform (see separate manual)
SMS alarm forwarding
Page 21
User’s Manual for Node M and Node C
Network Elements
For your notes:
Page 22
M0121A4A.doc
4 Installation
4. INSTALLATION
4.1.
MECHANICAL INSTALLATION
4.1.1. General
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
1. Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the
manufacturer are not met.
2. It is recommended only to use the mounting hardware delivered by the
manufacturer. If different mounting hardware is used, the specifications
for stationary use of the unit must not be exceeded.
) Note:
Exceeding the specified load limits may cause the loss of warranty.
3. The unit is considerably heavy. Make sure that a suitable mounting
surface is used. Ensure there is adequate manpower to handle the
weight of the system.
4. Due to power dissipation, the unit may reach a very high temperature.
Ensure sufficient airflow for ventilation.
Above and below the units a minimum distance of 300 mm to ceiling,
floor, etc. has to be kept. This distance must also be observed between
two units if they are mounted one above the other.
5. When connecting and mounting the cables (RF, mains, ...) ensure no
water can penetrate into the unit through these cables.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the unit.
) Note:
Node M and Node C are delivered with a pre-mounted front cover.
This cover is of vital importance for the correct forced airflow and
for passive cooling. Thus, do not operate the unit without cover.
Page 23
User’s Manual for Node M and Node C
Network Elements
4.1.2. Wall Mounting Procedure
Check the wall mounting kit and the wall to determine their suitability.
Mark the position of the drilling holes - four per unit - for the Node according to
figure 4-1. Please observe that the figure always shows a pair of drill holes for
each position. Only drill one of each pair.
figure 4-1 Positions of drilling holes
) Note:
Page 24
Ensure that there is free access to the electrical connections as well
as to the cabinet. The approved bending radius of the connected
cables must not be exceeded.
M0121A4A.doc
4 Installation
Drill four holes (four per unit) at the marked positions and insert dowels*.
The dowels are not part of the delivery (and thus not illustrated in the figure) since the suitable
type depends on the on-site conditions (the material of wall). Therefore, use dowels that are
appropriate for the mounting surface.
Use a cap nut or locknut to screw the four M8 screws into the dowels.
Use a hex wrench, opening 17 (old standard) or 16 (new standard), to loosen the
M10 hexagon head screws (four per unit) by which the mounting brackets are
fastened to the cabinet sides.
Mount the mounting brackets to the screws, and fasten them using the M8
washers, locking rings, and hex nuts that are part of the wall mounting kit.
Hang the cabinets into the brackets and fasten them with the M10 hexagon head
screws *.
figure 4-2 Wall mounting procedure
If other screws than the ones delivered by the supplier are used for fastening, these must have
a diameter of at least 8 mm and an appropriate length (depending on the dowels). Additionally,
make sure they are adequate for supporting a maximum weight of 50 kg per unit.
Page 25
User’s Manual for Node M and Node C
Network Elements
4.1.3. Pole Mounting Procedure
The following figure illustrates the pole mounting option back-to-back.
V1498A0
figure 4-3 Pole mounted units
Before starting the mounting procedure, check the pole diameter of the pole to which
the units will be installed.
Then, cut the thread-bolts (see table 4-2 Components of pole mounting kit, pos. 5) to
the required length according to the following table:
Pole-diameter (mm)
Length of thread-bolt (mm)
100 110 120 130 140 150 160 170 180 190 200
216 226 236 246 256 266 276 286 296 306 316
table 4-1 Required length of thread-bolts
Page 26
M0121A4A.doc
4 Installation
The pole mounting kit 'back-to-back' consists of the following parts in different
quantities:
No
Part
Pole mounting brace
Washer DIN 9021 – 8.4
Nut M8 DIN 934
Spring ring DIN 127 – A8
Thread-bolt M8
Washer M8 DIN 125
table 4-2 Components of pole mounting kit
The numbers in the above table refer to the numbering of the components in the
following figure.
figure 4-4 Back-to-back pole mounting
Dismount the mounting brackets from the cabinets of the units by loosening the
hexagon head screws M10x20 by which the mounting brackets are screwed to the
housing (four per unit).
Do not unscrew those screws, only loosen them by approx. three turns and take off
the brackets.
Fasten the mounting brackets to the pole using the corresponding mounting kit as
illustrated above.
Page 27
User’s Manual for Node M and Node C
Network Elements
For your notes:
Page 28
M0121A4A.doc
4 Installation
4.2.
ELECTRICAL INSTALLATION
4.2.1. General
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
1. This unit contains dangerous voltages. Loss of life, severe personal
injury or property damage can be the result if the instructions contained
in this manual are not followed.
2. It is compulsory to ground the unit before connecting power supply. A
grounding bolt is provided on the cabinet to connect the ground bonding
cable.
3. Although the unit is internally protected against overvoltage, it is
strongly recommended to earth the antenna cables close to the unit’s
antenna connectors for protection against atmospheric discharge. In
areas with strong lightning it is strongly recommended to insert
additional lightning protection.
4. Hard wired installation of mains supply for the unit requires an easily
accessible separation device in the mains circuit.
5. Make sure that an appropriate circuit breaker and an overcurrent limiting
device are connected between mains and the unit.
6. For unstable electric networks which frequently generate spikes, it is
advised to use a voltage limiting device.
7. A connection of mains supply to a power socket requires the power
socket to be nearby the unit.
8. The mains cable must be used exclusively for the repeater. Do not use
this cable for the power supply of other devices.
9. Incorrectly wired connections can destroy electrical and electronic
components.
10. To avoid corrosion at the connectors caused by electrochemical
processes, the material of the cable connectors must not cause a higher
potential difference than 0.6V (see electrochemical contact series).
11. It is sufficient to tighten the 7/16 or N antenna connector hand-screwed.
Any use of a tool (e.g. pair of pliers) might cause damage to the
connector and thus lead to malfunctioning of the unit.
12. The unit complies with the surge requirement according to EN 61000-4-5
(fine protection), however, it is recommended to install an additional
medium (via local supply connection) and/or coarse protection (external
surge protection) depending on the individual application in order to
avoid damage caused by overcurrent.
13. Observe the labels on the front panels before connecting any cables.
Page 29
User’s Manual for Node M and Node C
Network Elements
4.2.2. Grounding
Grounding must be carried out. Connect an earth-bonding cable to the grounding
connection provided at the outside of the remote unit. Do not use the grounding
connection to connect external devices.
figure 4-5 Grounding bolt
After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the figure above. Then, fasten all parts again with the hex
nut.
The PE cables must have a minimum cross section of 10mm2.
Page 30
M0121A4A.doc
4 Installation
4.2.3. Power Connection
Before connecting electrical power to the units, the system must be grounded as
described in the previous chapter. Mains power must be connected at the mains
connector. The power supply plug is included with the Node M/C.
The correct wiring of the power supply plug is as follows:
Mains
figure 4-6 Power supply
plug
figure 4-7 Mains connector of a Node M, exemplary
Mains
Coverage antenna
(to mobile)
Donor antenna
(to base station)
figure 4-8 Mains connector and antenna connections of a Node C, exemplary
Page 31
User’s Manual for Node M and Node C
Network Elements
PIN
Mains AC
Connection
Colour
Phase
brown
Neutral
blue
not connected
PE
green / yellow
Mains DC
Connection
Colour
not connected
-Vdc*
black
+Vdc*
red
PE
green / yellow
table 4-3 Pin assignment of mains connector
A minimum cross section of 1.5 mm2 is required for the power supply
connection. Each wire must observe the applicable national regulations
regarding loop impedance, voltage drop, and methods of installation. Make
sure to connect the correct voltage to the unit.
) Note:
Do not connect or disconnect the power cord at the mains
connector while power is on. Turn off mains** power before
connecting the power cord at the units, then, engage mains again.
* Black is always the negative potential while red is the positive one.
** Mains power must be interrupted with an external AC or DC breaker. For the AC or DC breaker,
observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50/60 Hz AC service is
needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service
or 16 Amps for 240-Volt service.
Option: 48 Vdc (36-72 Vdc). The external DC breaker should be 20 Amps.
Page 32
M0121A4A.doc
4 Installation
4.2.4. Connection of the Antenna Cables
The Node M/C’s antenna connectors are 7/16 female (optionally equipped with an N
female adapter). All connectors are located at the bottom of the cabinet. An operator
should refer to the documentation of the cable connector manufacturer for best
mating procedures. Furthermore, the bending radius of the antenna cables should be
maintained at all times.
There are several issues to be considered when selecting the cable and antenna
types.
Highly directional antennas with good front-back-ratios (40 dB is typical) are
recommended because they improve isolation and cell site selectivity.
Smaller diameter cables are less expensive and easier to install but have
worse performance.
Tighten the 7/16 or N connectors ONLY by hand. The use of pliers may cause
damage to the connector and impair the performance of the Node M/C.
Diversity
Mobile
Coverage antenna
(to mobile)
BTS
Donor antenna
(to base station)
figure 4-9 Front view of antenna connections from Node C, exemplary
Page 33
User’s Manual for Node M and Node C
Network Elements
4.2.5. Opening the Cabinet - Mains Power Switch
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings and
observe the following step-by-step procedure.
Do not operate the Node M/C without terminating the antenna connectors.
The antenna connectors may be terminated by connecting them to their
respective antennas or to a dummy load.
Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.
When opening the Node M/C do not damage the warranty labels on the
internal devices. The warranty is void if the seals are broken.
First remove the front cover
plate by loosening the four front
cover screws. The M5 socket
head cap screws are circlemarked in the figure to the left.
Do not remove those screws.
When they are loosened, the
front cover plate can be taken
off.
To open the housing, unscrew
the nine M5 socket head cap
screws (captive) of the top
cover.
figure 4-10 Front and top cover screws
) Note:
Page 34
Do not forget to reinstall the front cover afterwards to ensure safe
operation!
M0121A4A.doc
4 Installation
) Note:
Before closing the unit, make sure that the mains power switch
inside is set to ON.
figure 4-11 Position of mains power switch
Page 35
User’s Manual for Node M and Node C
Network Elements
For your notes:
Page 36
M0121A4A.doc
5 Functional Description
5. FUNCTIONAL DESCRIPTION
5.1.
DIGITAL ARCHITECTURE
The following figure shows the RF block diagram of the Node M/C.
figure 5-1 Configuration of a network element
The Node M/C is designed to amplify signals between multiple mobiles and a base
station in a UMTS/CDMA system. The unit consists of a filter and amplifier chain in
the downlink and one or two filters and amplifier chains in the uplink (primary and
diversity). The uplink and downlink paths are connected via a duplexer on both ends
of each path.
Page 37
User’s Manual for Node M and Node C
Network Elements
In the primary uplink path, a signal originating from the mobile is separated from the
downlink signal via the primary UL IN duplexer. It is then amplified by an integrated
low noise amplifier (LNA) and forwarded to the uplink digital channel module (DCM).
The DCM down-converts the signal to base-band, digitally filters it, amplifies it and
then up-converts it. In addition the interference cancellation technology is
implemented in the DCM. Finally, the signal is sent to the final amplifier (included in
DCM) and combined with the downlink input signal in the DL IN duplexer. The
optional diversity uplink path (via a second filter) is identical except signals enter via
the diversity UL IN duplexer and are combined in the DCM with the primary path.
In the downlink path, a signal originating from the base station is separated from the
uplink signal in the DL IN duplexer. It is then amplified by an integrated low noise
amplifier (LNA) and forwarded to the downlink digital channel module (DCM). The
DCM down-converts the signal to base-band, digitally filters it amplifies it and then
up-converts it. In addition the interference cancellation technology is implemented in
the DCM. Finally, the signal is sent to the final amplifier and combined with the uplink
input signal in the primary UL IN duplexer. The downlink DCM is also responsible for
communication and control of the entire unit.
Using a Node C 843 as an example, the following figure illustrates the positions of
the RF components inside the Node M/C.
Digital channel
module DL
Digital channel
module UL
Downlink final amplifier
Downlink final amplifier
Power supply unit
Coverage
duplexer
Donor
duplexer
figure 5-2 RF path of a Node C 843, exemplary
Page 38
M0121A4A.doc
5 Functional Description
5.2.
FEATURES
5.2.1. Filters Node M
Filters are set automatically according to the channels set in “Setup Wizard” or
“Technician Setup”. For further information about these menus refer to the user's
manual for Node software.
UMTS - Possible filters are:
One
UMTS
channel
MHz
One
UMTS
channel
5.2.2. Filters Node C
Filters are set automatically according to the channels set in “Setup Wizard” or
“Technician Setup”. For further information about these menus refer to the user's
manual for Node software.
CDMA - Possible filters are:
1.23
one CDMA
channel
16 x
1.23
MHz
sixteen adjacent
CDMA channels
Page 39
User’s Manual for Node M and Node C
Network Elements
5.2.3. Digital ICE (Digital Interference Cancellation Equipment)
Digital ICE has been developed to enhance antenna isolation. This feature enables
the Node M/C to provide coverage in areas where effectivity is decreased due to
physical site limitations which cause insufficient antenna isolation.
Antenna isolation is the RF loss measured between the donor antenna and the
coverage antenna. If the gain of the network element exceeds the path loss,
feedback in form of oscillation occurs. The isolation is usually dominated by the direct
path loss from one antenna to the other, but reflections can contribute to or even
affect antenna isolation. Digital ICE cancels the signal from the primary feedback
path, thus allowing the gain of the network element to be increased.
The required delay resulting from the on-site conditions is measured by the DCM and
set accordingly.
For software setting commands please refer to the online help screens.
The Digital ICE function can be enabled or disabled in the “Technician Setup” page.
Isolation and gain margin* can be checked in the “Status and Reports” menu
accessible via the home page of the web interface (see software manual).
* gain margin = antenna isolation minus Node M/C gain
5.2.4. VSWR (Voltage Standing Wave Ratio)
This feature enables the provider to query the status of the antenna system (antenna
and cable). The voltage standing wave ratio of the DL output antenna port is
measured.
If the VSWR falls below the value set in the Alarming Management of the software,
an alarm is released. The alarm can be forwarded to the OMC where the faults and
irregularities can be acknowledged and eliminated promptly.
The current VSWR value can be checked in the “Status and Reports” menu
accessible via the home page of the web interface.
Page 40
M0121A4A.doc
5 Functional Description
5.2.5. RSSI (Receive Signal Strength Indication)
The RSSI provides controlling and monitoring of the receive level of a base station
(DL RSSI) or user equipment (UL RSSI) to a Node M/C. It measures the level of the
input signal by detecting the RF and converting the analogue level into a digital
value. The data are processed and evaluated by software. An alarm will be released
if the measured signal level exceeds the alarm level set by the provider via software.
) Note:
If the Node M/C is equipped with a diversity path, both values will be
combined before the RSSI evaluation. Thus, only one UL value is
reported.
The current RSSI values can be checked in the “Status and Reports” menu
accessible via the home page of the web interface.
5.2.6. Alarm Forwarding
Alarms can be forwarded to a defined phone number or to the OMC if the Node M/C
is equipped with a modem or a mobile station. This enables the provider to control
and to query the status of the network via pocket switched or circuit switched
connection. Faults and irregularities can be recognized and eliminated.
With an optional modem the Node M/C also provides an SMS feature, by which the
unit is able to send out alarm messages as SMS. For further details please contact
your supplier.
Page 41
User’s Manual for Node M and Node C
Network Elements
5.2.7. Downlink Final Amplifier
For the Node M/C x37 an MCPA (multi carrier power amplifier) is used.
This is an error-correcting feed-forward amplifier. It has a high output power while
maintaining superior intermodulation and linearity performance.
figure 5-3 Node M/C x37 MCPA DL final amplifier
For the Node M/C x43 an MCPA (multi carrier power amplifier) with more output
power is used. This is an error-correcting feed-forward amplifier. It has a high output
power while maintaining superior intermodulation and linearity performance.
figure 5-4 Node M 2143 and Node M 1943 MCPA DL final amplifier
Page 42
M0121A4A.doc
5 Functional Description
figure 5-5 Node M/C 843 DL final amplifier
Page 43
User’s Manual for Node M and Node C
Network Elements
5.2.8. Power Supply Unit
The power supply unit is mounted in the door of the Node.
This device transforms mains power into a predefined DC voltage. When performing
maintenance, ensure that all circuits are voltage-free and that the Node M/C is
disconnected from mains.
figure 5-6 Power supply, Node M/C x37
figure 5-7 Power supply, Node M/C x43
Page 44
M0121A4A.doc
5 Functional Description
5.2.9. Modems
The modem is used to establish a remote connection to the Node M/C. The
connection may be used to change the parameters of the unit, check and clear
alarms or collect measurement and quality statistics.
Furthermore, the modem is at the Node M/Cs request to alert the operator when
there is an alarm. The modem may be over-the-air (wireless) or public switched
telephone network (PSTN). It is possible to install the wireless modem or the PSTN
modem on site.
Modem communication settings may only be changed locally. Should a different
modem be used, the operator should ensure that the settings are changed prior to
leaving the site.
Wireless modems allows remote control and maintenance of the Node.
Parameters may be changed; alarm and measurement statistics may be
acknowledged and collected in the OMC.
5.2.9.1. Illustrations of Modems
) Note:
The modems MC55, MC56, MC75
and HC25T are similar to modem
MC35.
figure 5-8 Modem MC35
) Note:
The modem Raven C3211 is similar to
modem Redwing.
figure 5-9 Redwing modem (CDMA)
Page 45
User’s Manual for Node M and Node C
Network Elements
figure 5-10 Modem AnyDATA iPORT
EMIII Dual / EM IV Dual
figure 5-11 Modem Raven XT
Page 46
figure 5-12 Modem MTCBA-C-N9
M0121A4A.doc
5 Functional Description
5.2.9.2. Modem Output
The modem output is connected to the 20 dB modem coupler port of the DL IN
duplexer or to the N-female connector near to the BTS port to connect an external
antenna.
figure 5-13 Cable from modem to donor
duplexer
figure 5-14 Cable from modem to
external modem antenna port;
Node M
Page 47
User’s Manual for Node M and Node C
Network Elements
5.2.10. Digital Channel Module (DCM)
The task of the digital channel module (DCM) is to filter and amplify any signals
passing through it. In addition it takes measurements of the input and output signals
and decodes the air interface to ensure proper setup and operation.
Finally it performs the interference cancellation algorithms, which eliminate the
normal problems associated with isolation, and has an integrated controller (in the DL
part) for the entire Node M/C, which maintains a web server for local and remote
communication. This process is accomplished by both analogue and digital means.
In case the diversity option is equipped, the module receives signals from both the
primary duplexer and diversity filter. Both signals are combined digitally and filtered
before being amplified in the uplink amplifier.
The DCM consists of an DL and UL part.
figure 5-15 Digital channel module,
DL part
No
11
figure 5-16 Digital channel module,
UL part
Explanation
Vdc and remote (RS232) for modem
Debug-connector
Fan connector (Node x43)
Vdc DL digital channel module
Battery backup connector
EAC-board connector
Internal DCM - DCM interface connection
Only one modem can be used at the same time.
Page 48
M0121A4A.doc
5 Functional Description
5.2.11. External Alarm Controller - EAC-Board
5.2.11.1.
Connectors on the EAC-Board - Description
The EAC circuit board is used for general purpose housekeeping functions of the
Node.
The EAC circuit board is the main connection point for the user. It has the external
alarm clamps, the connectors for local or modem connection, as well as a summary
alarm relay. The following figure shows an installed EAC-board.
DCM-A
10
DCM-B
11
DCM-C
figure 5-17 EAC-board, installed
Page 49
User’s Manual for Node M and Node C
Network Elements
Connectors on the EAC-board
No
1, 2
21
41
71
81
10
11
Explanation
USB connector for modem
Ethernet connector RJ45 for local and LAN web access
Internal DCM (DL) - DCM (UL) interface connection
Internal PSTN connector
Internal I2C (not used)
Battery disconnect button
External alarms, summary alarm LED & PSTN, see chapter 5.2.11.3
External Alarms
Summary alarm terminal; for pin assignment see chapter 5.2.11.4 Summary
Alarm
Internal PSU and I2C connection
Internal I2C (used for electronic door label memory board)
Door switch connector
Only these connectors are for general customer use. All others designated above are for
informative purposes, and required, only, e.g. for an upgrade or replacement of parts.
Only one modem can be used at the same time.
Connectors on the DCM DL module
See chapter 5.2.10 Digital Channel Module (DCM).
No
DCM-A
DCM-B
DCM-C
Page 50
Explanation
Fan connector (Node x43)
Vdc DL digital channel
module
Battery backup connector
M0121A4A.doc
5 Functional Description
5.2.11.2.
LEDs - Description
Seven LEDs are included on the EAC-board. They are controlled via the I2C bus.
figure 5-18 Function of LEDs on the EAC-board
Colours and illumination functions
No Colour Explanation
Yellow Ethernet connector LEDs, see chapter 3.1 Setting up a Local / LAN
Green Connection from Laptop / PC
DL PWR - illuminates when the DL Power is "Good" and the DL is
Green
NOT in battery backup.
UL PWR - illuminates when the software on the UL sets a bit in the
Green
FPGA indicating power is "good".
USER1 - illuminates when software activates. The LED is controlled
Blue
by software through the I2C bus.
ALARM - illuminates when a software defined alarm condition exists.
Red
This LED is controlled via the I2C bus.
BBU ACTIVE - when illuminated the DL-DCM is in battery backup
Yellow
mode.
Page 51
User’s Manual for Node M and Node C
Network Elements
5.2.11.3.
External Alarms
The external alarms are used to monitor the status of one or more external devices
via the Node M/C. A UPS or entry alarm is among the items that might be connected
to the contact relay and monitored via the Node M/C. The cage clamp connectors are
located on the EAC-board.
Observe that the cross-sectional area of the wires to be connected must be in the
range from 0.5 - 1.0 mm2. Do not use wire-end sleeves (wire cable ends).
n.c.
GROUND
n.c.
EXT_ALARM_3
GROUND
EXT_ALARM_2
GROUND
EXT_ALARM_1
10
PSTN_1_EXTERNAL
PSTN_1_INTERNAL
12
PSTN_2_EXTERNAL
11
PSTN_2_INTERNAL
14
GROUND
13
SUMMARY ALARM, LED GREEN
16
GROUND
15
SUMMARY ALARM, LED RED
16
15
figure 5-19 Pin assignment
figure 5-20 External alarm clamps, installed
External Alarms 1 to 3
Input voltage range
Recommended input line
Nominal sink current to ground
Active level
Connectors
Page 52
5 Vdc
Potential free
15 mA
High or low set via software
Cage clamps
M0121A4A.doc
5 Functional Description
figure 5-21 Configuration of external alarm clamps
All external alarms are defaulted to high (5 VDC) without connection. This setting
may be changed on the external alarm page to active high or active low. The severity
levels of the external alarms may be set via the web page. More information about
the external alarm settings is available in the web page and online-help.
Make sure that external alarms which are not required are set to active low or disable
them; otherwise the status will always show an alarm.
The names for each external alarm are user-definable on the external alarm page;
renaming them to indicate the use of these alarms is recommendable.
There are two external cable glands (PG7) at
the bottom of the Node. They may be used to
connect the external devices. Please note that
connecting the external devices by a wrong
type of cable may result in a loss of the waterproofness. The recommended cable diameter is
4 - 6 mm.
figure 5-22 External cable glands
Page 53
User’s Manual for Node M and Node C
Network Elements
5.2.11.4.
Summary Alarm
The summary alarm is a DC potential-free contact relay.
Observe that the cross-sectional area of the wires to be connected must be in the
range from 0.14 - 1.5 mm2.
Pin No:
figure 5-23 Summary alarm relay
The following table indicates the three-connector pin out.
Pin No
Contact
Maximum Resistive Load
Open in alarm condition
Max 1 A @ 50 Vdc
Common
Max 2 A @ 30 Vdc
Closed in alarm condition
Max 1 A @ 230 Vac
table 5-1 Pin assignment of relay contacts
B0185AHA
Pin 3
Pin 2
Pin 1
figure 5-24 Relay contacts, alarm condition
Page 54
M0121A4A.doc
5 Functional Description
5.2.12. Battery Pack - Battery On/Off
In case power fails, a battery backup system for controller and modem has been
implemented. This provides enough power for the controller that is integrated into the
DCM and the modem to operate for a limited period of time (battery backup time).
Within this time, the Node M/C will initiate a call to the OMC and alert the operator
that power has been lost. All other functions will cease to work in case of power
failure.
The battery pack is protected from deep discharge. When performing preventive
maintenance, make sure that all circuits are voltage free by disconnecting the battery
cable from the DCM. In case of a power cycle, it is sufficient to press the “Battery
disconnect button” on the EAC-board to interrupt the voltage supply. After mains is
connected again, the battery will be charged and the battery backup function will be
available again.
figure 5-25 Battery pack, exemplary
figure 5-26 Battery pack installed and its
connection to DCM
Page 55
User’s Manual for Node M and Node C
Network Elements
Battery On/Off
A pushbutton on the EAC-board is implemented to disconnect the battery pack from
the controller. This forces a hard reset of the system.
Once disconnected, the power to the controller will not be restored until the +28V
supply is again operational.
Battery
disconnect
button
figure 5-27 Position of the battery disconnect button
on the EAC-board
Page 56
M0121A4A.doc
5 Functional Description
5.2.13. UL and DL Duplexer
The duplexer is used to isolate the uplink from the downlink, i.e. to separate the
transmitting path from the receiving path. The pass band of the duplexer is the full
band (UMTS/CDMA). This allows the same Node M/C to be used regardless of its
operator’s frequency plan.
The UL and DL duplexers have multiple outputs, including the primary and extension
path, plus forward and reverse probes used for auto setup, VSWR, and RSSI
functions.
figure 5-28 Duplexer, UL IN
figure 5-29 Duplexer, DL IN
LNA
LNA
figure 5-30 Duplexers installed
Page 57
User’s Manual for Node M and Node C
Network Elements
Ceramic
duplexer
DL IN
figure 5-31 Duplexers installed, ceramic duplexer DL IN
Page 58
M0121A4A.doc
6 Maintenance and Replacement
6. MAINTENANCE AND REPLACEMENT
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
) Note:
Node M and Node C do not require any preventative maintenance
measures.
) Note:
In case of a defect replace the entire repeater. When sending back
the unit, use an appropriate packaging. We strongly recommend
using the original packaging!
7. ILLUSTRATIONS
7.1.
CABINET DRAWING
The cabinet measures of the Nodes described in this manual are nearly identical.
The following figure of a cabinet drawing exemplifies the proportions of Node M and
Node C.
figure 7-1 Cabinet of a Node M, respective Node C, exemplary
Page 59
User’s Manual for Node M and Node C
Network Elements
7.2.
LAYOUT OF THE NODE M/C 843
The following figure is exemplifying the layout of a Node M/C 843.
figure 7-2 Layout of the Node M/C 843, exemplary
Page 60
M0121A4A.doc
8 Index
8. INDEX
Abbreviations
AC Breaker - Mains Power
Address of Andrew Wireless Systems GmbH
Alarm Forwarding
Alarm LEDs - Description
Alarms (External)
Amplifier (Feed-Forward)
Andrew Solutions
32
13
41
51
52
42
11
Battery - On/Off
Battery Disconnect Button
Battery Pack
34
59
39
19
33
31
49
12
12
DCM
Declaration of Conformity
Design
Digital Channel Module
Digital ICE
Diversity
Duplexer
48
11
37
48
40
33, 48
57
29
23
LAN Connection
Layout of Node M/C 843
LNA
Local Connection
Low Noise Amplifier
56
56
55
Cabinet - Opening
Cabinet Drawing - Node M/C
CDMA - Standard Feature
Connection from Laptop or PC
Connections
Antenna
Power
Connectors on EAC-Board
Contact Addresses
Customer Support Addresses
Installation
Electrical
Mechanical
Look Up
Mains Power
AC Breaker
Switch
Maintenance
Modem
General
GSM
MC35
MC55/56
MC75
MTCBA-C-N9 (CDMA)
Raven C3211
Raven XT
Redwing (CDMA)
Mounting
Brackets
General
Hexagon Head Screws M10
Pole
Wall
49
19
49
52
53
Feed-Forward Amplifier
Filters Node C - Standard Feature
Filters Node M - Standard Feature
42
39
39
27
23
25, 27
26
24
44
Relay Contacts
Remote Connection
Replacement
RF Block Diagram
RF Path
RSSI
54
21
59
37
38
41
SMS Alarm Forwarding
Summary Alarm - Pin Assignment
41
54
30
UMTS - Standard Feature
Health and Safety Warnings
45
45
45
45
45
46
45
46
45
Grounding
32
35
59
Power Supply Unit
EAC-Board
Ethernet Connector
External Alarm Controller
External Alarms
External Cable Glands
20
60
57
19
LNA
39
VSWR
40
Page 61


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Tagged PDF                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2010:02:05 09:22:58+01:00
Creator Tool                    : Acrobat PDFMaker 8.1 für Word
Modify Date                     : 2010:02:05 09:29:49+01:00
Metadata Date                   : 2010:02:05 09:29:49+01:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Format                          : application/pdf
Creator                         : Raissa Panlilio
Title                           : Additional information on SM2009
Document ID                     : uuid:deaa8d22-1c5c-45d4-a258-60272bf1c4cf
Instance ID                     : uuid:c855d695-76df-4ed1-881e-1f7d0c505d7a
Company                         : Mikom GmbH
Source Modified                 : D:20100205082127
Page Count                      : 62
Page Layout                     : OneColumn
Author                          : Raissa Panlilio
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XS5-NCM843

Navigation menu