Angelcare Canada AC423R 900MHz Superheterodyne Receiver (Parent Unit) User Manual

Angelcare Monitors Inc. 900MHz Superheterodyne Receiver (Parent Unit)

User Manual

OWNER’S MANUALSOUND MONITORModel AC423XX XXXX XXXX XXDE XXXX XXEN 2FOR YOUR PEACE OF MINDSOUND MONITORModel AC423XXXXXXXXXXXXDEXXXXXXEN2
TABLE OF CONTENTWarnings ..................................................................................................... 3AC423 SETUP REQUIREMENTS........................................................7STEP 1 - Charge Parent Unit  ............................................................. 8STEP 2 - Setup Nursery Unit.............................................................. 9STEP 3 - Turn on your Monitor ........................................................10STEP 4 - Test and get to know your Monitor ............................. 11STEP 5 - Activate and deactivate additional functions ........14Troubleshooting ......................................................................................16Warranty  ...................................................................................................18Technical specifications ......................................................................19DEUTSCH.................................................................................................XXXX ...............................................................................................................XXOWNER’S MANUAL KEEP YOUR OWNER’S MANUAL FOR FUTURE REFERENCE.PLEASE READ THE WARNINGS AND INSTRUCTIONS CAREFULLY BEFORE  ASSEMBLING & USING THE PRODUCT.FAILURE TO FOLLOW THE WARNINGS AND THE INSTRUCTIONS COULD RESULT  IN SERIOUS INJURY OR DEATH OR DAMAGES TO THE PRODUCT. WARNINGAdult assembly required.Keep small parts away from children when assembling.We, at Angelcare®, stand behind all of our products.If you are not completely satisfied or have any questions,United States and Canada: please contact us at: anglecare@cdecinc.caOther countries: please contact your local Distributor.2
1. THIS PRODUCT CANNOT REPLACE RE-SPONSIBLE ADULT SUPERVISION. This product is designed to aid in the monitoring of your child. When using the monitor, you must still provide the supervision necessary for the continued safety of your child. Moni-toring of premature babies, or those consid-ered to be at risk, should always be carried out under the supervision of a health pro-fessional. This monitor is not intended to be used as a medical monitor.2.  STRANGULATION HAZARD. Children have STRANGLED in cords. Keep the Adapter cords out of the reach of children.  DO NOT put the Nursery Unit inside a crib or play yard. Because of the seri-ous strangulation risk to infants and toddlers, parents and caregivers should never place the Nursery Unit within 3 feet (1 meter) of a crib. NEVER use extension cords with AC Adapters. ONLY use the AC Adapters provided.3. When an AC Adapter is plugged into an electrical outlet, DO NOT touch the exposed end.4.  ALWAYS be sure that both the transmit-ter and receiver are working properly and are within range of each other. Test monitor be-fore first use, periodically and when changing location of the Nursery Unit.5. ALWAYS be sure to immediately check on baby whenever an alarm sounds. 6. DO NOT use monitor near water (such as bath tub, sink, etc.). CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENDO NOT EXPOSE TO RAIN OR MOISTURE7.  Keep monitor AWAY from heat sources (such as stoves, radiators, etc.). 8. ALWAYS place both the Nursery Unit and Parent Unit on a flat surface in an upright position and allow for proper ventilation. DO NOT place on sofas, cushions, beds, etc. which may block ventilation.9. This monitor uses public airwaves to trans-mit signals. The Parent Unit may pick up sig-nals or interference from other nursery moni-tors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use. If you experience in-terference, change the channel on both units.10. This product is NOT a toy. DO NOT allow children to play with it. 11.  This product contains small parts. Adult assembly required. Exercise care when un-packing and assembling the product and keep small parts away from children.12. Use and store the monitor at a tempera-ture between 50°F (10°C) and 104°F (40°C). BATTERY WARNING13. Use ONLY AAA RECHARGEABLE batter-ies for the Parent Unit. DO NOT mix old and new batteries. DO NOT mix alkaline, standard or rechargeable batteries. Insert batteries with correct polarity. DO NOT short-circuit supply terminals. ONLY use the recommend-ed batteries or equivalent (volts and size) and the correct adapter. Remove batteries when product is stored for long periods of time or when batteries are exhausted. Dispose ex-hausted batteries properly. DO NOT recharge non-rechargeable batteries. Rechargeable batteries are ONLY to be charged under adult supervision. Keep all batteries away from chil-dren. WARNING3E N
IMPORTANT SAFETY INSTRUCTIONS14.1 Read these instructions - All the safety instructions should be read before the prod-uct is operated.14.2 Keep these instructions. The safety and operating instructions should be retained for future reference.14.3 Heed all warnings – All warnings on the product and in the operating instructions should be adhered to.14.4 Follow all instructions – All operating and use instructions should be followed.14.5 Water and moisture - DO NOT use this apparatus near water. For example, near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet environment or near a swim-ming pool and the like. Care should be taken so that objects DO NOT fall onto units and that liquids are not spilled into unit through its openings.14.6 Cleaning - Disconnect all units before cleaning. DO NOT immerse in water any part of the Nursery Unit, Parent Unit. Clean only with dry cloth. DO NOT spray with cleaning products or solvents.14.7 Ventilation - DO NOT block any ventila-tion openings. Allow for proper ventilation when units are in use. DO NOT cover the Nursery Unit or Parent Unit with any object such as a blanket. DO NOT place it in a draw-er or in any location which would muffle the sound or interfere with the normal flow of air.14.8 Heat sources - DO NOT install near any heat sources such as radiators, heat registers, stoves, TVs or other apparatus (including am-plifiers) that produce heat. Heat can damage the case or electrical parts.14.9 Power cord protection - Protect the Adapter’s power cord from being walked on or pinched by furniture or other items – Pow-er supply cords should be routed so that they are not likely to be walked on or pinched by items upon or against them, paying particular attention to cords and plugs, convenience re-ceptacle, and the point where they exit from the product.14.10 Accessories - Only use attachments/ac-cessories specified by the manufacturer. DO NOT place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult and serious damage to the product. Use ONLY with a cart, stand, tripod, bracket or table recommended by the manufacturer or sold with the product. Any mounting of the product should follow the manufacturer’s instructions.14.11 Unplug this appliance during lightning storms or when not used for long periods of time.14.12 Servicing - DO NOT attempt to service this product yourself as opening or removing covers (except battery doors) may expose you to dangerous voltage or other hazards.14.13 Replacement parts - When replacement parts are required, be sure the replacement parts specified by the manufacturer have the same characteristic as the original part. Unauthorized substitution may result in fire, electric shock or other hazards.14.14 Usage - This baby monitor is intended as an aid. It is NOT a substitute for responsible and proper adult supervision and should not be used as such. Use this appliance ONLY for its intended use as described in this manual.14.15 Power Sources - Operate this product only from the type of power source indicated on the type plate of the adaptor.  If you are unsure of the type of power supply to your home, consult your dealer or local power company.14.16 Overloading - DO NOT overload wall outlets, extension cords or integral conve-nience receptacles as this can result in a risk of fire or electric shock.14.17 Object and Liquid Entry - NEVER push objects of any kind into this product through casing slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. NEVER spill liquid of any kind on the product.14.18 Antenna - The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.9”) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.14.19 Power Lines - An outside antenna sys-tem should NOT be located in the vicinity of overhead power lines or other electric light or power circuit, or where it can fall into such power lines or circuits as contact with them may be fatal.4
14.20 STRANGULATION HAZ-ARD. Children have STRANGLED in cords. Keep the Adapter cords out of the reach of children. Because of the serious strangulation risk to infants and toddlers, parents and caregivers should NEVER place the Nursery Unit within 3 feet (1 meter) of a crib. NEVER use extension cords with AC Adapters.  ONLY use the AC Adapters pro-vided.14.21 Interference - This monitor uses public airwaves to transmit signals. The Parent Unit may pick up signals or interference from oth-er nursery monitors in your area. Your moni-tor may even be picked up by other house-holds. To protect your privacy, make sure both units are turned OFF when not in use. If you experience interference, change the channel on both units.IMPORTANT SAFETY INSTRUCTIONS  RELATED TO USE OF BATTERIES15.1 Use ONLY the type and size of batter-ies specified in the owner’s manual. There is a risk of explosion if batteries are replaced with an incorrect type.15.2 Use ONLY AAA rechargeable batter-ies and/or the AC Adapters provided for the Parent Unit. You must use only rechargeable batteries in the Parent Unit. DO NOT use al-kaline batteries or you will severely damage the unit.15.3 Charge the batteries for 15 hours prior to first use. Be sure to have the monitor in the OFF position during this period. ONLY use the AC Adapters included with your monitor.15.4 DO NOT use these adapters with any other equipments.15.5 When unplugging the AC Adapter from the Nursery Unit, be sure it is switched to the OFF position. If it isn’t, the unit will revert to battery mode if batteries are installed.15.6 DO NOT use rechargeable batteries in the Nursery Unit. Use alkaline batteries ONLY.15.7 DO NOT dispose batteries in fire. They may explode. Check with local regulations for possible special disposal instructions.15.8 Exercise care in handling batteries in or-der not to short out the batteries with con-ducting materials such as rings, bracelets and keys. Overcharging, short circuiting, reverse charging, mutilation, or incineration of batter-ies must be avoided to prevent one or more of the following occurrences: release of toxic materials, release of hydrogen and/or oxygen gas, rise in surface temperature.15.9 DO NOT attempt to recharge batteries provided with or identified for use with this product that are not intended to be charged. The batteries may leak corrosive electrolyte or explode.15.10 DO NOT attempt to rejuvenate the bat-teries provided with or identified for use with this product by heating them. Sudden release of battery electrolyte may occur, causing burns or irritation to eyes or skin.5E N
15.11 If and when necessary, the batteries must be replaced with identical new ones or equivalent (volts and size). If a battery to be replaced is connected with other batteries in series, replace the other batteries at the same time as well. DO NOT mix old and new bat -teries.15.12  Reverse polarity installation of the bat -teries in the end product must be avoided. Reverse insertion of batteries can cause charging, and that may result in leakage or explosion.15.13  Remove batteries from this product if you store the product over 30 days because the batteries could leak and damage the product.15.14  Discard ‘dead’ batteries as soon as pos -sible since ‘dead’ batteries are more likely to leak in a product. If a battery has leaked or vented, it should be replaced immediately us -ing protective gloves.15.15  DO NOT store this product, or the bat -teries provided with or identied for use with this product, in high-temperature areas.   WARNING (North America Only)16.1 Modications not authorized by the man -ufacturer may void users authority to operate this device.16.2  NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm -ful interference in a residential installation. This equipment generates, uses and can ra -diate radio frequency energy and, if not in -stalled and used in accordance with the in -structions, may cause harmful interference to radio communications. 16.3  However, there is no guarantee that in -terference will not occur in a particular instal -lation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encour -aged to try to correct the interference by one or more of the following measures:t  Reorient or relocate the receiving   antenna.t  Increase the separation between     the equipment and receiver.t  Connect the equipment into an     outlet on a circuit dierent from that    to which the receiver is connected.t  Consult the dealer or an experienced     radio/TV technician for help.16.4  This device complies with part 15 of the FCC Rules. Operation is subject to the follow -ing two conditions:(1)  This device may not cause harmful inter -ference, and(2)  This device must accept any interference received, including interference that may cause undesired operation. FCC AND IC REGULATIONSRF radiation exposure statementThe Nursery Unit complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. Caution: To maintain the compliance with the FCC’s RF exposure guideline, install the Nursery Unit at least 20cm from nearby baby and persons. Industry CanadaThis product meets the applicable Industry Canada technical specications.This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to thefollowing two conditions: (1) this device may not cause interference, and (2) this device must acceptinterference that may cause undesired operation of the device.CAN ICES-3 (B)/NMB-3(B)6
IMPORTANTPlace the crib near a supporting wall and far from air currents. Install the Nursery Unit on a flat, stable surface facing the crib at a distance of at least 1 meter (3 feet).WHAT YOU WILL NEED (NOT INCLUDED):Rechargeable Parent Unit 2 AC AdaptersNursery Unit 3 AAA rechargeable  batteries for Parent Unit4 AAA Alkaline  Batteries for Nursery Unit SOUND MONITORModel AC423BABY’S ROOM:IMPORTANTSETUP REQUIREMENTS4X3XINCLUDED:Miniature Phillips Screwdriver2XKeep  at least  1 m (3 ft) apart7E N
STEP 1 - CHARGE PARENT UNIT (12 HOURS)2 31)  Remove the battery cover and insert the Rechargeable Batteries (included).2)  Connect the AC Adapter to the Parent  Unit and into an electrical outlet.3)  Charge the unit for 12 continuous hours (prior to first use). NOTE:To optimize your battery performance please refer to Battery Guidelines in the Trouble Shooting section p.16.12IMPORTANTNever use regular alkaline batteries in the Parent Unit; they may explode. PARENT UNIT:Front View Rear ViewEGHICDA) LCD Screen B) Power ON/OFF C) Channel ButtonD) Mute ButtonE) Sound Volume  Up/DownF) SpeakerG) Belt ClipH) Battery CoverI)  AC Adapter OutletFBA18
STEP 2 - SETUP NURSERY UNIT21)  Remove the battery cover and insert 4 AAA Alkaline Batteries (not included).2)  Place the Nursery Unit at a minimum  of 1m (3ft) away from the crib.3)  Connect the AC Adapter to the Nursery  Unit and plug into an electrical outlet. NOTE:The batteries maintain power  supply in case of power outage. NURSERY UNIT:Front View Rear ViewAIKA) SpeakerB) Low Battery Indicator C) Power ON IndicatorD) MicrophoneE) Out-of-Range Switch  ON/OFFF) Power ON/OFF G) Night Light Button /  Channel SelectionH) SpeakerI)  AC Adapter Outlet J)  Volume Sensitivity DialK) Battery Cover3BCDJHE FG1  1 m  (3 ft) 9E N
1)  Press the Channel button  to enter the channel mode.2)  Press and hold the Nusery Unit back button until the Night Light flashes.3)  Press and release the Nusery Unit back button to change the channel your monitor transmits on (C1 to C8).4)  Press and hold the Nusery Unit back button until the Night Light stops flashing to confirm your channel selection and quit to normal mode. NOTE :   If the transmission is not clear, or if you hear    interference sounds, you should change   the channel.STEP 3 - TURN ON YOUR MONITOR1)  Press the Parent Unit ON/OFF button  for 2 seconds.2)  Slide ON the Nursery Unit Power  ON/OFF button.NOTE:The screen of the Parent Unit will show  the channel of transmission (C1 to C8).  Then temperature reading will replace  the channel display.If there is no temperature display, turn OFF and then ON the Nusery Unit again. The channel display will then turn to temperature reading  in one minute.CHANNEL SELECTION1 21234TO SELECT THE CHANNEL:If there is a lost connection  between the 2 units  (refer to troubleshooting p.16):•  The Out-of-range icon    (if activated) will blink    on the screen and the Parent    Unit will beep.The Antenna icon  will blink.The Antenna icon  will blink with present  of the channel  number display10
Nursery Unit:   Appears when the Nusery Unit battery is lowOut-of-Range:  Indicates the loss of connection between the Parent Unit and Nursery Unit.Parent Unit:  Appears only when the Parent  Unit is in channel selection mode.Sound: Indicates sound activation. Flashing when speaker is muted.Temperature Display:  Indicates room temperatureIMPORTANT ICONSChargingChannel Display:  Indicates selected channelVolume/ Microphone Sensitivity Level:  Indicates speaker volume  and sound level.Battery Level icon: Indicates battery level   Empty   1/2 Full   FullTO TEST SOUND:Ask someone to speak into the Nursery Unit or place the unit near a radio to ensure  that sound is being picked up. IF YOU HEAR NO SOUND:•  Check that both units are switched on.•  Check that both units are plugged into  functioning electrical outlets.•  Check the batteries in both units  (replace or recharge them as necessary per unit).•  Bring the Parent Unit closer  to Nursery Unit.IMPORTANTTo avoid feedback (whistling),  keep both units at least 3 meters apart (10 feet).4.1 - SOUND STEP 4 - TEST AND GET TO KNOW YOUR MONITORADJUST THE SOUND LEVEL   PUT IN TEMPORARY MUTE MODE Raise volumeLower volumePress the Mute button once  to mute the sound (see step 5.3). 11E N
You can adjust the Nursery Unit  sensitivity dial to change your microphone from less sensitive to very sensitive.  This sensitivity dial is located on the back of the Nursery Unit.TO ADJUST THE MICROPHONE SENSITIVITY LEVEL: 4.2 - BATTERIES 4.3 - MICROPHONE SENSITIVITY LEVEL HOW TO CHECK THE BATTERIES:Unplug the AC Adapters from both units.• If the Nursery Unit Power Indicator   does not show or if the Low Battery    Indicator does show, replace   the batteries.HOW TO CHARGE THE BATTERIES  IN THE PARENT UNIT: Plug the AC into the Parent Unit and  a working electrical outlet. Your Parent Unit can function with the batteries  at 1/2 capacity but it is recommended that they are fully charged before unplugging from the AC Adaptor and power outlet  for maximum use.PARENT UNIT BATTERY ALARM•  Alarm activates when batteries need to be recharged.•  Parent Unit will emit a beep sound every 15 seconds. •  Battery Alarm icon will show on screen.The Power Indicator  on the Nursery Unit The Low Battery Indicator on the Nursery Unit empty 1/2 full full•  If the Parent Unit screen does not    light up or it switches off, recharge   the batteries.12
Temperature Unit: Celsius Out of Range: OFFSpeaker Volume Level: 3 Microphone Sensitivity Level: MiddleNight Light: OFFDEFAULT SETTINGS YOU ARE NOW READY  TO USE YOUR MONITORThe Angelcare® monitor can be used with the pre-program factory settings  or you can also customize your settings to your preference.IMPORTANT•  Test your monitor before first use.•  Test your monitor regularly to ensure it is functioning correctly. 13E N
5.1 - OUT-OF-RANGE Your monitor has an Out-of-Range function that advises you when the Parent Unit cannot receive the signal from the Nursery Unit. Out-of-Range situations can be caused by distance or by physical interferences.RANGE: Up to 250 meters / 820 ft (open field)TO ACTIVATE THIS FUNCTION:OUT-OF-RANGE ALARM•  Alarm activates when your two units are not communicating.•  The Parent Unit will emit a double beep every 8 seconds.•  Out of Range Icon will flash on the screen.IMPORTANTIf the Parent Unit is OFF after out of range function being set ON, it is needed to reset and reactivate the function to ON again. To reset it, make sure the Parent Unit is ON again and slide the Nursery Unit switch to OFF and then slide the switch to ON again  as to reactivate the Out of range function.STEP 5 – ACTIVATE AND DEACTIVATE ADDITIONAL FUNCTIONS The Angelcare® monitor can be used with the pre-program factory settings  or you can also customize your settings to your preference.TO STOP THE OUT-OF-RANGE ALARM:Press 2 seconds  to turn the Parent  Unit OFF ORTurn the Nursery Unit ONSlide the Out-of-Range button on the Nursery Unit  to turn it ON or OFF. The Out-of-Range Indicator  will blinks on the Parent Unit.The Out-of range Icon will also flash when channel is being changed or the unit is reconnectingONOFF14
Press the Night Light button  on the back of the Nursery Unit  to turn it ON or OFF. 5.2 - NIGHT LIGHT5.3 - TEMPORARY MUTEAllows you to put your monitor  in temporary Mute mode.TO ACTIVATE MUTE: Press the Mute button.TO DEACTIVATE MUTE: Press the Mute button again  to hear sounds.NOTE:The Sound Icon will blink on the Parent Unit whilst the Temporary MUTE  is activated.After 2 minutes the sound function  will be automatically reactivated.When the Nusery Unit power source is the adapter, the night light is illuminated from all edge sides of the Nusery Unit body.When it is used with battery only, the night light is illuminated only from top edge of the Nusery Unit.If you press too long on the  Sound/OFF button it will shut  down the Parent Unit.15E N
TROUBLESHOOTINGTAKING CARE OF YOUR RECHARGEABLE BATTERIES•  Ensure that you fully charge your batteries for 15hrs before their first use. •  To maintain maximum battery life it is recommended that you fully discharge    your batteries periodically. Battery performance can be diminished by leaving    the batteries constantly charging. If your parent unit is not in use, please turn it off. •  Inadequate battery power can impair the performance of your monitor. If you are not   happy with the performance of your Parent Unit/Monitor please replace the rechargeable    batteries (4 x NiMH Rechargeable Batteries). •  It is advisable to change the batteries every 6 months.NO SOUND IS BEING TRANSMITTED•  Change to the following as some text regarding MUTE is duplicated:•  Ensure that both units are switched ON.•  Check that the sound has not been turned down on the Parent Unit. Increase the volume    level on the Parent Unit, refer to step 4.1.•  Check on the Parent Unit screen to see if the monitor is in temporary MUTE mode    instead of ON mode. Deactivate the temporary MUTE function, refer to step 5.3. •  If there is no power to any unit check/replace the batteries, recharge the Parent Unit    & check the AC Adaptors are working.  Change electrical outlets if required.•  Bring the Parent Unit and Nursery Unit closer together.NURSERY UNIT POWER ON INDICATOR (GREEN LIGHT) DOES NOT LIGHT UP•   Switch OFF and back ON the Nusery Unit.•   Check connections or change to another electrical outlet.WEAK RECEPTION•   Bring units closer together.•   Change the position of one or both units.•   Place units on a flat surface away from baby’s reach.•   Replace the batteries or recharge Parent Unit.STATIC, DISTORTION, INTERFERENCES  (FROM OTHER MONITORS, WIRELESS PHONES, WALKIE-TALKIES, ETC...)• Rotate Parent Unit or move it away from source of interference.• Try a different channel, refer to step 3.16
FEEDBACK (LOUD NOISES EMITTED FROM THE PARENT UNIT)•  Move units farther apart (at least 3 meters/10 feet apart).•  Decrease volume on Parent Unit.THE PARENT UNIT SCREEN IS BLACK (PARENT UNIT IS OFF)•  Turn the Parent Unit back ON by pushing and holding the power button.•  Replace the batteries or recharge Parent Unit.If you experience a problem that is not noted in this manual,  please do not return the product to the store. If you are not completely satisfied or have any questions:United States and Canada: please contact us at: angelcare@cdecinc.caOther countries: please contact your local Distributor.We may have a simple solution to your problem.17E N
LIMITED WARRANTYAngelcare® warrants to the original owner of this product that Angelcare® rechargeable, sound monitor (model AC423) is free from any material and workmanship defects, for a period of one (1) year (rechargeable batteries not included) from the date of the original purchase. If this monitoring system fails to function properly when used as directed under normal conditions within the one year period, Angelcare® will either repair or replace the product, at our discretion, free of charge. Please contact your distributor.The product must be accompanied by a proof of purchase, either a bill of sale or other proof that the monitoring system is within the warranty period. Angelcare® will bear the cost of repairing or replacing the product and shipping it back to you.This warranty does not apply to a product which has been damaged as a result of improper maintenance, an accident, improper voltage supply or any other form of misuse. The warranty is also void if the owner repairs or modifies the product in any  way. Angelcare® is not liable for any incidental or consequential damages with regard  to this product. The warranty also excludes any liability other than what is stated above. No other warranty is given.LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,  SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING  FROM THE USE OF THIS PRODUCT.IMPORTANT! This Angelcare® monitor is a personal care product. Please do not return this product  to the store. If you have questions or need help, please call your distributor before returning this product.18
TECHNICAL SPECIFICATIONSRange:   up to  820 ft. (250m)Number of Channels:   USA/C anada: 8 channels.  Europe: 8 channels.Power Supply:   4 AAA alkaline batteries (not included)   or 100-240V AC/7.5V DC adapter   for Nursery Unit.3 AAA rechargeable batteries and   100-240V AC/7.5V DC adapter   for the Parent Unit.Caution:  To reduce the risk of electric shock, do not expose this product to rain   or moisture.Danger of explosion if batteries are incorrectly replaced. The included Batteries are 3 AAA NIMH rechargeable batteries, manufactured by GPI INTERNATIONAL LIMITED (GN60AAAHC, 1.2V 600mAh) or by HIGHPOWER TECHNOLOGY CO., LTD (HFR-44AAAJ600, 1.2V 600mAh). They may only be replaced by 3 AAA NIMH rechargeable batteries.E rP COMPLIANCESOUTH AFRICA-BRAZIL-ECUADOR-EUROPEAN UNIONUse only Angelcare ® Brand power supply-model number T07505V001 GERMANYUse only Angelcare ® Brand power supply-model number T07505F002 AUSTRALIAUse only Angelcare ® brand power supply-model number T07505S002 NORTH AMERICAUse only Angelcare ® brand power supply-model number T07505U002 UK-MALTA-ASIA-CYPRUSUse only Angelcare ® brand power supply-model number T07505B001PROTECT THE ENVIRONMENTThis electronic equipment contains reusable material and must not be disposed   with domestic waste. Please take it to a collecting point for electric and electronic equipment (ask your local authorities for details).Batteries:t  DO NOT mix old and new batteries.t  DO NOT mix alkaline standard     (carbon-zinc), or rechargable     (NI-CD, NIMH, etc) batteries.Transmission:  Transmission from the Nursery Unit to the Parent Unit is made on the 864 MHz frequency in Europe/Asia/Africa and on the 927 MHz frequency for North America/Ecuador/Oceania.This Device complies with the requirements set out in the R&TTE 1999/05/EC Directive.19E N
IM423-INT-101813

Navigation menu