AnyDATA AGT100D CDMA Position reporting device User Manual Modem Connection Setup Manual

AnyDATA Corporation CDMA Position reporting device Modem Connection Setup Manual

User Manual

                             Asset Tag  Users  Manual  (AGT-100D)  CDMA ASSET TAG Users Manual  July, 2006AGT-100D – v 1.3            AnyDATA  AnyTime AnyPlace Any Wireless Data Solutions™ All Rights Reserved.                                                          1/16
                             Asset Tag  Users  Manual  (AGT-100D)   AnyDATA CDMA AGT-100D Copyright © 2005 AnyDATA Corp. All Rights Reserved.  Any part of this document may not be distributed, communicated, reproduced or transmitted in any form or by any means, electronic or mechanical or otherwise, for any purpose, without the permission of AnyDATA Corp.  This document can be subjected to revision without further notice.   Contact Address   Headquarter AnyData Corporation 18902 Bardeen Ave, lrvine,  CA 92612-1522 U.S.A. http://www.anydata.net e-mail: info@anydata.com Rep:1-949-833-0011 Fax: 1-949-833-0022  AnyData(China) 489 Song Tao Road, Sector B, 1st Fl. Pudong ZhanJiang Hi- Tech Park, Shanghai, 201203,  P.R.China http://www.anydata.net.cn e-mail: info@anydata.net.cn Rep:+86-21-5080-4828 Fax:+86-21-5080-3828  AnyData.Net Inc.(Korea) DaeGo Bldg, 8th., 1591-10 Kwanyang-dong, Dongan_gu, Anyang City, Kyunggi-do Korea. http://www.anydata.co.kr e-mail: infodata@anydata.net Rep:+82-31-380-7100 Fax:+82-31-476-6021        All Rights Reserved.                                                          2/16
                             Asset Tag  Users  Manual  (AGT-100D)   Contents Contents ................................................................................................................................ 3 Figures .................................................................................................................................. 4 Tables .................................................................................................................................... 4 1 Introduction .................................................................................................................... 5 1.1 Purpose .......................................................................................................................5 1.2 Technical Detail.....................................................................................................5 1.3 Revision History.....................................................................................................5 2 Physical Contents .......................................................................................................... 6 3 Description: Asset Tag ................................................................................................ 8 4 Charging the Asset Tag .............................................................................................. 10 4.1 RS-232C Cable w/ Power Adaptor connecter..................................................10 4.2 Wall Charger...........................................................................................................10 5 Powering On/Off the Asset Tag ................................................................................ 12 5.1 Powering On.............................................................................................................12 5.2 Powering Off...........................................................................................................12 5.3 Resetting the AGT-100D ......................................................................................12 6 Checking the Asset Tag Status ................................................................................ 14 6.1 CDMA Status (Red LED) ........................................................................................14 6.2 Battery Status (BLUE LED) ................................................................................14 6.3 External Power Status (Red LED) ....................................................................14 7 GEO Fence On/Off (Optional) .................................................................................... 15 7.1 Set Geo Fence On...................................................................................................15 7.2 Set Geo Fence Off.................................................................................................15 8 Alert Message (Optional) .......................................................................................... 16  All Rights Reserved.                                                          3/16
                             Asset Tag  Users  Manual  (AGT-100D)   Figures  Figure 2.1: Package Contents ..........................................................................................6 Figure 2.2: External Interface ......................................................................................7 Figure 2.3: LEDs ...................................................................................................................7 Figure 4.1: RS-232C Cable w/ Power Adaptor............................................................10 Figure 4.2: Asset Tag w/ External Power ..................................................................11 Figure 5.1: Reset Button.................................................................................................13  Tables  Table 1.1: Revision History ............................................................................................5 Table 6.1: CDMA Status (Red LED) ................................................................................14 Table 6.2: Battery Status (Blue LED) ........................................................................14        ! Warning:  Exposure to Radio Frequency Radiation The radiated output power of this device is below the FCC radio frequency exposure limits.  Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized.  In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, the gain of the external antenna must not exceed 1dBi. This device is compliant with the parameters of Specific Absorption Rate (SAR) government regulations. This device contains AnyDATA DTG2000-DUAL V2.0 module whose FCC ID is P4M-DTG2000V2 and IC Certificate number is 4594A-DTG2KV2. All Rights Reserved.                                                          4/16
                             Asset Tag  Users  Manual  (AGT-100D)   1 INTRODUCTION 1.1 PURPOSE This manual discusses the purpose and usage of the Asset Tag (AGT-100D). 1.2 TECHNICAL DETAIL Please refer to  Technical Manual.pdf for a more detailed description of the AGT-100D  1.3 REVISION HISTORY The revision history for this manual is shown in Table 1.1.   Table 1.1: Revision History Version Date  Description v 01  Feb 2006  Initial Release – applicable AGT-100D v 03  Mar 2006  Minor Editing Done V 1.0  Apr 2006  Minor Editing Done V 1.1  Jul 2006  Added Alert Feature V 1.2  Jul 2006  FCC Warning Statement Included V 1.3  Jul 2006  Added description on how to start alert feature All Rights Reserved.                                                          5/16
                             Asset Tag  Users  Manual  (AGT-100D)   2 PHYSICAL CONTENTS  Figure 2.1: Package Contents The box should contain: One AGT-100D Asset Tag One ATG-100D Belt Clip One RS-232C Cable w/ Power Adaptor connecter One Power Adaptor One Wall Charger One Application/Manual CD If any of items on Figure 1.1 are missing, please contact AnyDATA. All Rights Reserved.                                                          6/16
                             Asset Tag  Users  Manual  (AGT-100D)   Power     GEO Fence Set / CDMA Status External Battery Custom RS-232C Figure 2.2: External Interface      GEO Fence /  CDMA Status Led Power Led Figure 2.3: LEDs  All Rights Reserved.                                                          7/16
                             Asset Tag  Users  Manual  (AGT-100D)   3 DESCRIPTION: ASSET TAG  The Asset Tag is a CDMA position reporting device that will let you keep track of your most important assets. By using the following features, the device can be used to track packages, people, and even pets.    Continuous Tracking – This application will allow you to keep a close watch on your important asset. The device will connected to a web-based application and provide you up to date information on its current position.    Interval Tracking – This application will allow you to keep a watch on your important asset. By setting a specific interval, the device can be set to report to a web-based application to provide you information on the location of your asset.    Geo Fence – A Geo Fence is an invisible perimeter set to a specified origin by specifying the latitude and longitude. When activated, the AGT-100D will check its current position on a specified interval time period, changeable through the server. If the position returned is outside of the Geo Fence radius, the AGT-100D will alert the server with the Crossed Geo Fence Index and the current position of the device. If the AGT-100D crosses back into the Geo Fence, it will send one more alert with the current position of the device.  Currently, the AGT-100D is capable of supporting up to 3 different Geo Fences. All 3 Geo Fences can be active at one time. Each Geo Fence can be configured using a server designed to interact with the AGT-100D  The AGT-100D can also be configured to allow the user to set a Geo Fence using the SET button on the device (this feature will be determined by All Rights Reserved.                                                          8/16
                             Asset Tag  Users  Manual  (AGT-100D)  the company supporting the device). When the user is allowed to set a Geo Fence, the server will only have permission to configure the Interval and/or Radius of the user-defined Geo Fence. Only the user can turn the Geo Fence ON and OFF.  All Rights Reserved.                                                          9/16
                             Asset Tag  Users  Manual  (AGT-100D)   4 CHARGING THE ASSET TAG 4.1 RS-232C CABLE W/ POWER ADAPTOR CONNECTER 1. Connect the power adaptor to the RS-232C Cable (See Figure 4.1).  2. Connect the RS-232C Cable to the bottom of the Asset Tag (See ).  Figure 4.2Figure 4.23. Plug power adapter to an outlet (The RS-232C cable does not need to be plugged in the computer for the Asset Tag to charge). 4. The Red LED should turn to indicate the Asset Tag is charging.  4.2 WALL CHARGER 1. Connect the wall charger to bottom of the Asset Tag (See ).  2. Plug charger to an outlet. 3. The Red LED should turn on to indicate the Asset Tag is charging.   Figure 4.1: RS-232C Cable w/ Power Adaptor  All Rights Reserved.                                                          10/16
                             Asset Tag  Users  Manual  (AGT-100D)   Figure 4.2: Asset Tag w/ External Power All Rights Reserved.                                                          11/16
                             Asset Tag  Users  Manual  (AGT-100D)   5 POWERING ON/OFF THE ASSET TAG  5.1 POWERING ON Press the PWR button to power up the Asset Tag. The Red LED will blink once indicating the Asset Tag is powering up. 5.2 POWERING OFF Press and hold the PWR button for approx. 2 seconds to power down the Asset Tag. Both the Red LED and Blue LED will turn off during the power down procedure. Both LEDs will turn off when the Asset Tag has powered down. 5.3 RESETTING THE AGT-100D In case the AGT-100D does not respond or appears to be locked up, the unit may be forced to do a reset. On the back of the unit, there is a small hole with the reset button inside. To reset, do the following: 1. Using a small pin, insert it into the hole (See Figure 5.1). 2. Press until a soft click it felt, hold for approximately 2 seconds. 3. The Red LED should turn on and then turn off when the phone is done powering on. All Rights Reserved.                                                          12/16
                             Asset Tag  Users  Manual  (AGT-100D)   Reset Hole Figure 5.1: Reset Button All Rights Reserved.                                                          13/16
                             Asset Tag  Users  Manual  (AGT-100D)   6 CHECKING THE ASSET TAG STATUS    To check the current status of the Asset Tag, press the SET button while the device is turned on. Both LEDs will blink showing the current status of the Asset Tag. Table 6.1 below describes the CDMA status, and Table 6.2 describes the Battery Status. 6.1 CDMA STATUS (RED LED) Table 6.1: CDMA Status (Red LED) # of blink  Description 1 Idle 2 In use 3  No service / Offline  6.2 BATTERY STATUS (BLUE LED) Table 6.2: Battery Status (Blue LED) # of blink  Description 1 Nearly empty 2 0 bar 3 1 bar 4 2 bar 5 3 bar 6 4 bar  6.3 EXTERNAL POWER STATUS (RED LED) Red LED will always be ON while the Asset Tag is on external power. Blue LED will turn ON when fully charged.  All Rights Reserved.                                                          14/16
                             Asset Tag  Users  Manual  (AGT-100D)   7 GEO FENCE ON/OFF (OPTIONAL) GEO Fence #1 may be turned on and off by pressing and holding the set button on the device.  NOTE: This feature will be enabled/disabled by the application provider. 7.1 SET GEO FENCE ON  Press and hold the SET button for approx 3 seconds. The GEO Fence LED will blink continuously while it sets the origin. If the origin is set, the LED will stay ON, if it fails, the led will turn OFF. 7.2  SET GEO FENCE OFF Press and hold the SET button for approx 3 seconds. The GEO Fence LED will stay turned OFF when the GEO Fence is off.  NOTE: The Radius and Interval will be set to the current setting. If no Radius or Interval has been set, they well be set to the default values. Radius = 100M, Interval = 5 Minutes. The Origin will be set to the current location of the device. Please note the Origin can take up to 10 minutes to set depending in the environment the device is currently in.  All Rights Reserved.                                                          15/16
                             Asset Tag  Users  Manual  (AGT-100D)   8 ALERT MESSAGE (OPTIONAL)  This feature will send an alert message with the current position to the application provider. To send the Alert Message, press the “Set” button 2 consecutive times (within 3 seconds). The device will then attempt to obtain the current position and report it to the application provider. When received, the application will do the appropriate processing.    NOTE: This feature will be enabled/disabled by the application provider.  All Rights Reserved.                                                          16/16