Apc Smart Ups 2200 Xl Users Manual SU IM 990 4651A 002 MN01 EN
3000 XL to the manual 151e060a-2364-4740-a5dd-b37d45626319
2015-02-03
: Apc Apc-Smart-Ups-2200-Xl-Users-Manual-470884 apc-smart-ups-2200-xl-users-manual-470884 apc pdf
Open the PDF directly: View PDF .
Page Count: 10
Download | |
Open PDF In Browser | View PDF |
Installation Guide Smart-UPS™ X 2000/2200/3000 XL Tower/Rack-Mount 4U Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed. The following safety messages may appear throughout this manual to warn of potential hazards. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage. Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety Guide supplied with this unit before installing the UPS. • Adhere to all local and national electrical codes. • This UPS is intended for indoor use only. • Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. • Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. • The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life. • Connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords. • The batteries are heavy. Remove the batteries prior to installing the UPS in a rack. • Always install external battery packs (XLBPs) at the bottom of the rack. The UPS must be installed above the XLBPs. • The UPS display interface will recognize as many as 10 external battery packs connected to the UPS. However there is no limit to the number of XLBPs that can be used with the UPS. • Refer to Specifications in the Operation manual for UPS and battery weight. Inventory Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged. Included with all models 1 pair rail cleats 8 pan head screws 1 pair tower stabilizer brackets Use 8 flat head screws to secure tower stabilizer brackets to the UPS 1 pair rack-mount brackets Use 8 flat head screws to secure rack-mount brackets to the UPS Use 4 ornamental screws to secure rack-mount brackets to the rails Install a cage nut in the rack to secure the top hole of each rack-mount bracket in a four post rack (1) Documentation CD (1) PowerChute software CD Rack-mount support brackets and hardware 1 pair support brackets Two post racks 10 screws Included with models that have factory installed Network Management Cards Four post racks 6 screws 6 washers Included with High Voltage (HV) models 2 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U Product Overview Front panel features 1 Online LED 2 Power ON/OFF button 3 On Battery LED 4 Site Wiring Fault LED 5 Replace Battery LED 6 LCD display screen APC by Schneider Electric 7 UP/DOWN arrow keys 8 ENTER key 9 ESC key su0343a Rear panel features 1 SmartSlot 7 Controllable Outlet Group 3 2 Chassis ground screw 8 External battery pack connector 3 UPS utility power input 9 EPO connector 4 Circuit Breaker reset : Serial port 5 Controllable Outlet Group 1 ; USB port 6 Controllable Outlet Group 2 2000 VA, 120 Vac Low Voltage 3000 VA, 120 Vac Low Voltage GROUP 2 GROUP 1 GROUP 3 su0756a su0757a Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U 3 2200/3000 VA, 230 Vac High Voltage 3000 VA, 208 Vac High Voltage GROUP 1 GROUP 1 GROUP 2 GROUP 3 GROUP 2 GROUP 3 su0754a su0755a Remove Battery CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL • • • • The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. The UPS + the battery weighs 41 kg (90.4 lb). The battery weighs 23.8 kg (52.4 lb). Remove the battery before installing the unit in a rack. Use the battery handle to lift and slide the battery out of the UPS. Failure to follow these instructions can result in equipment damage and minor or moderate injury 4 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U su0760a 3 su0759a 2 su0758a 1 Tower Configuration 2 su0761a 1 s u07 4 su0774a 3 63a s u07 6 4a su0762a 5 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U 5 Rack-Mount Configuration CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL • • • • The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. The UPS + the battery weighs 41 kg (90.4 lb). The battery weighs 23.8 kg (52.4 lb). Remove the battery before installing the unit in a rack. Use the battery handle to lift and slide the battery out of the UPS. Failure to follow these instructions can result in equipment damage and minor or moderate injury Tower to rack-mount conversion 1 2 s u07 s u 07 64b 4 5 su0761b su0583b 3 63b 6 su0766a s u0 7 6 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U 69a CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL • When installing equipment in a rack, always install external battery packs at the bottom of the rack. • The UPS should always be installed above the external battery packs in rack or stack configurations. Failure to follow these instructions can result in equipment damage and minor or moderate injury Two post rack installation 1 2 3 s u07 70a 68a su0776a s u07 5 6 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U su0772a su0771a su0773a 4 7 Four post rack installation Use an APC by Schneider Electric four post rail kit. To order the rail kit go to the APC by Schneider Electric Web site apc.com. 1 2 3 su0777a 78a su07 4 5 su07 79a su 07 6 80a 7 81a su0782a su07 UPS Configuration Connect Emergency Power Off feature For instructions on how to connect the Emergency Power Off (EPO) switch, refer to the Operation and Maintenance manual on the Documentation CD (supplied). Configure controllable outlet groups The outlets on the UPS are configured into groups. To utilize the controlled outlet features, use the Advanced menus on the display interface and navigate to: Main Menu > Control > Outlet1 Control. 8 Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U Electrical connections CAUTION RISK OF EQUIPMENT DAMAGE • Adhere to all local and national electrical codes. • Wiring should be performed by qualified electrician. • Always connect the UPS to a grounded outlet. Failure to follow these instructions can result in equipment damage U PS su0788a vice i c De n e o tr D e v ic E le c ronic t c le E Smart-UPS X 2000/2200/3000 VA XL Tower/Rack-Mount 4U 9 Select models are ENERGY STAR® qualified. For more information go to www.apc.com/site/recycle/index.cfm/energy-efficiency/energy-star/ © 2013 APC by Schneider Electric. APC, the APC logo, Smart-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners. EN 990-4651A-002 03/2013
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : scoleman Title : SU IM 990-4651A-002 MN01 EN.fm Create Date : 2013:03:28 14:25:40Z Creator Tool : FrameMaker 8.0 Modify Date : 2013:04:02 13:19:51Z Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:f9dd3f51-4416-4bc6-807c-4f93293b73cb Instance ID : uuid:63f21ff7-3ac3-4156-a517-e735c4bf3b82 Page Count : 10 Author : scolemanEXIF Metadata provided by EXIF.tools