Aprilaire Humidifier 600M Users Manual 10008975A AA 600
600M to the manual 403ad891-df51-4e4b-b505-8771f9244667
2015-02-03
: Aprilaire Aprilaire-Humidifier-600M-Users-Manual-467254 aprilaire-humidifier-600m-users-manual-467254 aprilaire pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION ATTENTION INSTALLER: This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock. This product must be installed in compliance with all local, state and federal codes. Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices. MODEL 600 SERIES HUMIDIFIER WARNING CAUTION 1. ELECTRICAL SHOCK HAZARD. Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock. SPECIFICATIONS RISK OF PROPERTY AND EQUIPMENT DAMAGE. HUMIDIFIER DIMENSIONS 1. Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home. 5. Do not connect Model 600 or 600M transformer to blower motor wiring. Premature component failure may result. 2. Do not install humidifier or bypass connection on the furnace jacket. 6. When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control. 2. SHARP EDGES HAZARD. Sharp edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork. 3. Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier. 3. RISK OF SCALDING. Water temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line. 4. Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home. DIGITAL HUMIDIFIER CONTROL ADHC TERMINAL STRIP C INPUTS A B ODT W OUTPUTS G H H Gf NORTH, EAST OR WEST SIDE OF HOME 3 gph ELECTRICAL DATA 24 VAC-60 Hz, 0.5 AMP INSTALLATION OPTIONS S SUPPLY R C C G G Y Y W W THERMOSTAT RETURN 110 VAC CONNECT DRAIN CONNECT TO LINE HERE HOT WATER SUPPLY FURNACE 90-1510 MANUAL CONTROL WATER FEED RATE YELLOW WIRES R Model 600M 10”W x 12 3 ⁄ 4”H Upflow OUTDOOR TEMPERATURE SENSOR FOR AUTOMATIC MODE ABOVE EXPECTED SNOW LINE PLENUM OPENING The Model 600 and 600M Aprilaire can be installed on either the supply or return plenum of a forced air handling system and is easily reversible for installation with right hand or left hand bypass duct connections. The humidifier dimensions S and serviceability must be considered when selecting the best location for the humidifier. Here are 2 examples of many types of installations. Model 600 R 6” diameter 8. Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums. (SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS) POWER BYPASS DUCT OPENING 7. Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction. RECOMMENDED WIRING DIAGRAMS Width (including solenoid valve): 15 3⁄ 8” Height (including drain spud): 15 3⁄ 4” Depth: 10 1 ⁄ 4” CONTINUOUSLY POWERED 24 VAC TRANSFORMER PROVIDED WITH HUMIDIFIER Horizontal IMPORTANT USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE. • DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT. R RETURN 24 VAC FURNACE ACCESSORY TERMINALS OR TRANSFORMER (10VA MINIMUM) SHUT-OFF (SADDLE VALVE) SUPPLY WATER SUPPLY COMMON 90-1079 MODEL 50 CURRENT SENSING RELAY (IF REQUIRED) HI LO IMPORTANT FURNACE BLOWER MOTOR YELLOW 24V SOLENOID VALVE WIRES WHEN MODEL 50 CURRENT SENSING RELAY IS USED: • WIRE MODEL 50 CURRENT SENSING RELAY INTO 24 VAC HUMIDIFIER CONTROL CIRCUIT ONLY! DO NOT INSTALL IN TRANSFORMER PRIMARY CIRCUIT. NOTE 90-1207 When installing the Aprilaire humidifier with the Aprilaire Digital Humidifier Control or on a heat pump system, use hot water. The heated water supplements the reduced supply air temperature as added heat for evaporation. CONNECT DRAIN LINE HERE RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357 – TOP – READ REVERSE SIDE FIRST! READ REVERSE SIDE FIRST! READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION Figure 1 FURNISHED ITEMS Figure 2 Figure 3 Built-in bypass damper 24 VAC Transformer Digital Humidifier Control (Model 600 only) Manual Humidifier Control (Model 600M only) Humidifier Control Installation Instructions Saddle valve Humidifier Installation Template ITEMS NOT FURNISHED Mounting screws (sheet metal screws) Water supply line ( 1⁄ 4” copper) Drain line ( 1⁄ 2” I.D. hose) Low voltage wire Bypass ductwork Model 50 Current Sensing Relay (if required) 1. Press top & bottom tabs to remove cover (1). Pull feed tube (3) out of distribution tray (4). Remove Water Panel® Evaporator assembly. See Figure 1. 2. Humidifier is supplied with bypass duct connection on left. For right side bypass, swap location of drain spud (9) and cap (10). Twist to remove spud and cap. 3. Position template on supply or return plenum. Make sure template is level. Allow clearance for drain line and for servicing. Trace template outline. Cut 10” wide x 12-3/4” high opening. Avoid injury from sharp edges. 90-1067 90-1068 4. Place humidifier base (2) in 7. Control installation opening and secure with 6 screws in openings provided. and wiring. Disconnect electrical power to furnace before wiring control. In order for humidifier to operate, furnace must be on and RH must be below set-point of control. Wiring diagrams illustrate recommended method of detecting furnace operation. 5. Select location for 6” collar on opposite plenum to minimize length and number of elbows in bypass duct. Install 6” bypass duct components. Attach duct to humidifier collar using 2 screws in openings provided. 6. Insert Water Panel Evaporator assembly into base. Make sure bottom of scale control insert (6) is in drain spud. Snap top of evaporator assembly into base. Insert feed tube into distribution tray. See Figure 2. Rotate nameplate (11) if necessary, so it is right side up. Place point bypass damper handle (8) to “WINTER” (open) for heating season and “SUMMER” for cooling season. MANUAL HUMIDIFIER CONTROL, MODEL 600M: Manual Control can be mounted in return duct or on wall in living space. Knob and cover must be removed to mount control. See wiring diagram for 24V control connections. PARTS LIST 1. Front Cover 2. Base 3. Feed Tube 4. Water Distribution Tray 5. Water Panel Evaporator 6. Scale Control Insert 7. Integral Damper 8. Damper Handle 2 9. Drain Spud 10. Hole Plug 11. Nameplate 12. Solenoid Valve 12 10 4 5 1 8 9 6 TEMPLATE MUST BE LEVEL • For wall-mount, select location that will not be affected by drafts or heat sources. Remove and discard foam gasket and secure control to wall over wire access opening using screws & anchors provided. DIGITAL HUMIDIFIER CONTROL, MODEL 600: • Select location for control on return duct at least 6” upstream of bypass duct connection or humidifier. Drill 3/4” hole for sensor. Knob and cover must be removed to mount control. Place control on duct with RH sensor extending into duct opening. Make sure gasket is in place around sensor cage. Secure control to duct using 2 screws in openings provided. • See wiring diagrams on template and control instructions for 24 V control connections. 3 7 90-1250 • For return duct mounting, position template at least 6” upstream of bypass duct connection or humidifier. Avoid injury from sharp edges when cutting opening. Make sure foam gasket is in place and secure control to duct using 2 screws in holes provided. 11 90-1069 8. Humidifier will function with cold, hot, softened or unsoftened water. Hot water (140°F max) is strongly recommended to provide maximum evaporative capacity. Saddle valve provided may be used to tap into water supply. See installation instructions on saddle valve package. Saddle valve is designed to be fully opened or closed. Do not use to regulate flow. 9. Run 1/4” copper tubing from saddle valve to solenoid valve. DOUBLE-WRENCH TO PREVENT LEAKING. See Figure 3. 10. INSTALL DRAIN IN ACCORDANCE WITH LOCAL CODES. Run 1/2” I.D. hose from drain spud to floor drain. Make sure drain has constant downward slope and is not kinked. Do not over-tighten hose clamp onto drain spud. Do not use solvent adhesive on drain spud. 11. Check humidifier operation. Open saddle valve and turn control to highest setting. Turn on furnace. Allow humidifier to run until water flows from drain. Make sure all electrical connections are secure and all plumbing connections are water-tight. Set control to proper setting. NOTE: BEFORE LEAVING THE JOB SITE, MAKE SURE: 1. Saddle valve is fully open. 2. All plumbing connections are watertight. 3. Humidifier functions properly. 4. Bypass damper is in proper position. IMPORTANT! Be sure owner’s manual containing instructions for operation and warranty information is given to owner in order to avoid unnecessary calls. Warranty is void unless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product. 10008975 B2205117A 4.10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 X Press Private : %%DocumentCustomColors: (PANTONE 2955 U).%%DocumentProcessColors: Cyan Magenta Yellow Black.%%QRKLabCustomColor: .354 .48 .412 (PANTONE 2955 U).%%RGBCustomColor: .153 .267 .397 (PANTONE 2955 U).%%EndComments Creator : QuarkXPress(R) 7.31 Create Date : 2010:04:27 09:26:32 Producer : QuarkXPress(R) 7.31 Modify Date : 2010:04:27 09:26:32 Title : 10008975A AA 600 TemplateEXIF Metadata provided by EXIF.tools