THE POND MASTERS
GUIDE TO
GUIDE TO
Aquagarden
for Fountains, Filters
and Waterfalls
2500
Established over 40 years ago, Blagdon are
committed to producing a comprehensive
range of high quality, easy to use, pond
equipment. An ongoing programme of
research and development ensures
excellent performance and value for all
their customers. This product excellence is
demonstrated by Blagdon’s award winning
range of water gardening equipment. As
a result Blagdon’s reputation for quality is
unrivalled amongst experienced pond
gardeners and retailers alike.
Blagdon - The Pond Masters
The name you can rely on
www.aquagarden-range.co.uk
Interpet, Vincent lane
Dorking, Surrey, RH4 3YX
Leaflet Code: AG PUMPS 2-a
Produced exclusively by
Aquagarden 2500.qxd 16/12/10 09:30 Page 1
Congratulations on buying an Aquagarden Pond pump
fountains filters and waterfalls Fountain and Water
Feature Pump. Aquagarden pumps are high quality
pumps manufactured with advanced technology, to run
pond fountains filters and waterfalls.
The powerful motors are easy to maintain having a
single moving part impeller system featuring highly
wear-resistant ceramic shaft design.
IMPORTANT
Please attach proof of purchase to this manual
and file in a safe place.
GUIDE TO
1
Aquagarden pond for
Fountains, Filters and
Waterfalls 2500
Aquagarden 2500.qxd 16/12/10 09:30 Page 3
GETTING TO KNOW YOUR AQUAGARDEN PUMP
2 3
Getting to know your Aquagarden pump
Parts descriptions / spares codes - with exploded diagram
Technical specifications
Pump performance / flow chart
Installation
Electrical installation
Installing pump in pond
Maintenance and cleaning
Cleaning
Step by step guides
Routine maintenance
Monthly maintenance
Annual maintenance
Winter storage
Troubleshooting
Troubleshooting and maximise performance
Faults - problem procedure
Returning faulty pumps
Consumer advice contact details
Guarantee
3
4
5
5
6
6
7
9
9
9-10
9
10
10
10
11
11
12
12
12
13
CONTENTS
Aquagarden 2500.qxd 16/12/10 09:30 Page 5
GETTING TO KNOW YOUR AQUAGARDEN PUMP
POND PUMP
2500
1
Pump performance / flow chart
Technical Specification
& Performance
GETTING TO KNOW YOUR AQUAGARDEN PUMP
POND PUMP very small pond 2500
Lift Flow rates lph
2.0 metres 240 lph
1.5 metres 800 lph
1.0 metres 1200 lph
0.5 metres 1640 lph
0.0 metres 2200 lph
Flow is given as optimum rate
4 5
POND PUMP very small pond 2500
Cable Fitted 10 metres
Voltage 230V
Hertz 50Hz
Watts 48
Safety Rating IP68
Maximum Depth 2.2 metres
Maximum Lift 2.2 metres / 7’2”
Parts 1-3, 5-8, 10-18 and 20-22 are supplied as one package.
17 18 19
420
21
22
5
3
16
15
10
14
9 7 8
24
6
2
13
12
11
23
No. Part Description Blagdon Code
1 Pre-filter cage front
2 Pre-filter cage back 1040495
3 Pre-filter cage insert base
4 Foam pre-filter 1040501
5 Double daisy jet
6 Daisy jet
7 Bell jet 1040518
8 Foam jet
9 20 cm extension 1040525
10 Fountain T piece
11 T connector 1040532
12 Fountain flow control
No. Part Description Blagdon Code
13 T connector O ring
14 Outlet cap
15 3/4" hose tail
16 1/2" hose tail 1040532
17 1/2" outlet hose tail
18 3/4" outlet hose tail
19 1" flow control valve 1040563
20 Intake cage
21 Impeller cover 1040549
22 Impeller cover O ring
23 Impeller complete 1040556
24 Motor N/A
For spares for your Aquagarden product select compatible Blagdon spare part numbers
Aquagarden 2500.qxd 16/12/10 09:30 Page 7
Electrical installation
The power supply must meet the specifications on the product.
The pump is intended to be used with either a weather-proof
cable connector or permanently connected to the fixed wiring
in the main system other than by means of a plug and socket.
The cores in the supply cable are coloured in accordance with the following
code: Brown = Live, Blue = Neutral, Green/Yellow = Earth.
The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.
Do not use the supply cable to lift the pump as this may cause damage.
WARNING - THIS PUMP MUST BE EARTHED
A Residual Current Device (RCD), also know as the Residual
Current Circuit Breaker (RCCB), with a tripping current not
exceeding 30mA must be installed in the supply circuit.
A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the fixed wiring.
INSTALLATION INSTALLATION
For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond pump (i.e. local building regulations).
These pumps must not be used in swimming pools, or areas where people are
in contact with the water.
Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled. Consult a qualified electrician if in
any doubt about wiring this product to the main supply.
Warning - The pond pump is provided with a thermal
cut out that temporarily switches off the pump in case of
overheating and the pump may automatically restart.
6
IMPORTANT: Please note all electrical work on garden lighting and
power installations must comply with part P of the building regulations.
Failure to comply is a criminal offence. If the installation of this product
is not carried out by a competent electrician who is registered under the
Part P self-certification scheme then you must notify the local building
control department before work begins. For further information and
guidance on this matter and other electrical installations in your home
that might be covered by the relevant legislation, contact your local
authorities building control department.
Locating your Aquagarden pump
The Aquagarden pump should be located on a firm and level base in the
pond/water feature in a depth of at least 10cm, but no more than 2m.
It is advisable to keep the pump off the bottom of the pond to avoid silt
entering the pump causing excessive wear and increasing pre-filter cleaning.
Fountain
Make sure there is ample cable from mains supply. Place pump in desired
location. Add Fountain extension pipes so fountain head is above surface of
the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’
diagram below. See "Getting to know your Aquagarden" for parts and
descriptions.
If using the Daisy or Double Daisy Jet, cleaning of the jets will be reduced by
inserting the optional pre-filter foam included.
Tip: Ensure that any fountain, waterfall, filter or feature fitted does not empty
water out of pond/water feature. In windy conditions it may be necessary to shut
off or reduce the height of your fountain display to prevent water loss. Also see
the explanatory diagram on the top face of your Aquagarden pump carton.
7
Never run the pump out of water as this may cause irreparable damage.
Aquagarden 2500.qxd 16/12/10 09:30 Page 9
Warning - Failure to carry out routine maintenance leaving the
pump under reduced or no flow conditions for long periods
(i.e. blocked pre-filter) will result in a shorter pump life and
will invalidate the guarantee.
Aquagarden 2500 is a centrifugal pump with a magnetic impeller
movement driven by a watertight synchronous motor. They require minimum
cleaning, only periodic cleaning of the pre-filter and impeller is necessary.
Routine Maintenance
Carry out routine maintenance when pump flow is visibly reduced.
1. Switch off electricity.
2. Remove pump from pond (do not use the cable to lift the pump).
3. Remove the front of the pre-filter cage by depressing the button and pulling
apart. Wash the cage thoroughly in fresh water. A blocked pre-filter will
reduce pump flow. Follow steps 1 and 2.
MAINTENANCE & CLEANING
STEP 1: POND PUMP 2500 (ROUTINE)
Firmly pull pre-filter cage from pump
motor.
STEP 2: POND PUMP 2500 (ROUTINE)
Remove pre-filter foam (if fitted), and
wash thoroughly in fresh water. The
pre-filter is for use with Daisy Jets only.
A blocked foam will reduce the pump
flow rate.
8 9
Tip: Ensure that any fountain or feature fitted does not empty water out of
pond/water feature. The Bell Jet and Foam Jets do not need the foam pre-filter
so require little maintenance when used with the pre-filter cage only.
Water Feature
Install as for Fountain. Depending on water feature to be supplied, your pond
pump can be used with the 1/2" hose fitting or 3/4" outlet hose fitting which
can be screwed directly into pump body. Hose clips should be used to secure
hose.
Tip: The larger 1" hose will give maximum performance when fitted.
INSTALLATION
BELL FOUNTAIN
Adjust bell by
moving head higher
for small bell and
lower for a wider
bell shape.
ADJUSTING FLOW CONTROL
Turn clockwise to increase,
anti-clockwise to
reduce flow.
DEPRESS
BUTTON
Aquagarden 2500.qxd 16/12/10 09:30 Page 11
STEP 3: POND PUMP 2500 (MONTHLY)
Remove impeller
cover by turning
anti-clockwise
to release lock.
Then pull firmly
away from
pump motor
and cage.
DAISY
To clean, remove
head and rinse.
Use optional foam
pre-filter with Daisy
Jet heads.
10 11
Problem
Low flow from pump
1. Follow routine cleaning procedure if no improvement.
2. Follow monthly cleaning procedure.
3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed
or kinked.
4. Keep the height that water is to be pumped from the water surface (called
Head) to a minimum. The higher the head the lower the flow rate and the
more wear on the pump.
5. Use the largest diameter, smoothest bore pond hose over the shortest
distance and keep hose fittings to a minimum. This removes frictional loss
of flow and so increases pump flow rates.
Poor Fountain performance
Reduced height.
Jets blocked.
Use foam insert with Daisy Jets
for lower maintenance.
No flow from pump
1. Check power supply is on.
2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION).
3. Follow low flow procedure as above.
If none of the above works contact Interpet (Blagdon) Consumer Advice
Department (See Faults problem procedure Page 12).
TROUBLESHOOTINGMAINTENANCE & CLEANING
Monthly Maintenance
Following as for Routine Maintenance (steps 1 and 2) and then
steps 3, 4 and 5.
Annual Maintenance
Dismantle pump and examine all parts for wear or damage, replacing any
parts that show obvious wear and/or damage. (See getting to know your pump
for parts/description and replacement parts codes.) Particular care should be
taken to examine the cable entry point and the cable; if there is any sign of
damage the pump should be discarded.
Winter Storage
The pump can be run in the pond during the winter but care should be taken
to ensure that it is fully immersed and cannot freeze solid. If the pump is not
used during the winter, follow annual maintenance procedure and store frost-
free in the house or garage until spring.
Remove impeller
from pump motor.
Wash parts with
fresh water carefully.
STEP 4: POND PUMP 2500 (MONTHLY)
Aquagarden 2500.qxd 16/12/10 09:30 Page 13
12
FAULTS - PROBLEMS PROCEDURE
Before returning your Aquagarden pump to your dealer or contacting our
Consumer Advice Department, please carry out the following steps.
This will solve most problems quickly and easily.
1. Ensure electrical procedure has been followed fully. Check fuse and any
cable connectors/switch boxes.
NOTE: If the pump has overheated the thermal overload will temporarily
switch off the pump.
2. (a) Follow routine maintenance and check pump. (b) Follow monthly
maintenance and check pump. (c) Follow troubleshooting guide.
(d) Follow annual maintenance guide.
3. Return pump to point of purchase for inspection and advice (You may
need proof of purchase).
Consumer Advice contact details
Interpet (Blagdon) Consumer Advice Department
Vincent Lane, Dorking, Surrey RH4 3YX
Telephone: 0845 226 7437
(Monday to Friday 10am to 4pm except Bank Holidays - Times may vary)
Fax: 01306 876712
E-mail: customercare@interpet.co.uk
IMPORTANT
This product is guaranteed against defects in material and workmanship for
2 years from the date of purchase, under normal usage. The guarantee
DOES NOT APPLY in case of improper use, negligence, lack of maintenance
or accidental damage either to the pump or to the impeller or impeller shaft.
If the pump fails due to a manufacturing fault within this period it will be
either repaired or replaced free of charge. Liability is limited to replacement
of the faulty product only, no other costs will be reimbursed.
This guarantee is not transferable and does not affect your statutory rights.
This guarantee does not confer any rights other than those expressly set out
above. Excludes the sponge pre-filter, which should be replaced every six
months and the impeller, which may require replacing annually. If any parts
need replacing, spares are available from your retailer.
GUARANTEE
Environment friendly disposal
You can help protect the environment.
Please remember to respect the local regulations: hand in the non-working
electrical equipments to an appropriate waste disposal centre.