Aquagarden 2500.qxd

16/12/10

09:30

Page 1

Produced exclusively by

GUIDE TO
Established over 40 years ago, Blagdon are
committed to producing a comprehensive
range of high quality, easy to use, pond
equipment. An ongoing programme of
research and development ensures
excellent performance and value for all
their customers. This product excellence is
demonstrated by Blagdon’s award winning
range of water gardening equipment. As
a result Blagdon’s reputation for quality is
unrivalled amongst experienced pond
gardeners and retailers alike.

Blagdon - The Pond Masters
The name you can rely on
www.aquagarden-range.co.uk
Interpet, Vincent lane
Dorking, Surrey, RH4 3YX
Leaflet Code: AG PUMPS 2-a

Aquagarden
for Fountains, Filters
and Waterfalls
2500
THE POND MASTERS
GUIDE TO

Aquagarden 2500.qxd

16/12/10

09:30

Page 3

GUIDE TO

Aquagarden pond for
Fountains, Filters and
Waterfalls 2500
Congratulations on buying an Aquagarden Pond pump
fountains filters and waterfalls Fountain and Water
Feature Pump. Aquagarden pumps are high quality
pumps manufactured with advanced technology, to run
pond fountains filters and waterfalls.
The powerful motors are easy to maintain having a
single moving part impeller system featuring highly
wear-resistant ceramic shaft design.

IMPORTANT
Please attach proof of purchase to this manual
and file in a safe place.
1

Aquagarden 2500.qxd

16/12/10

09:30

Page 5

CONTENTS

GETTING TO KNOW YOUR AQUAGARDEN PUMP

Getting to know your Aquagarden pump

3

Parts descriptions / spares codes - with exploded diagram

4

Technical specifications

5

Pump performance / flow chart

5

Installation

6

Electrical installation

6

Installing pump in pond

7

Maintenance and cleaning

9

Cleaning
Step by step guides

9
9-10

Routine maintenance

9

Monthly maintenance

10

Annual maintenance

10

Winter storage

10

Troubleshooting

11

Troubleshooting and maximise performance

11

Faults - problem procedure

12

Returning faulty pumps

12

Consumer advice contact details

12

Guarantee

13

2

3

Aquagarden 2500.qxd

16/12/10

09:30

Page 7

GETTING TO KNOW YOUR AQUAGARDEN PUMP

GETTING TO KNOW YOUR AQUAGARDEN PUMP

6

POND PUMP
2500

Pump performance / flow chart
5

9

7

8

12

14

17 18

19

15
1

4

20

10

16
21

23

13
11

POND PUMP

very small pond 2500

Lift

Flow rates lph

2.0 metres

240 lph

1.5 metres

800 lph

1.0 metres

1200 lph

0.5 metres

1640 lph

0.0 metres

2200 lph

Flow is given as optimum rate

2
22

Technical Specification
& Performance

24

POND PUMP

3
For spares for your Aquagarden product select compatible Blagdon spare part numbers
No. Part Description

1
2
3
4
5
6
7
8
9
10
11
12

4

Pre-filter cage front
Pre-filter cage back
Pre-filter cage insert base
Foam pre-filter
Double daisy jet
Daisy jet
Bell jet
Foam jet
20 cm extension
Fountain T piece
T connector
Fountain flow control

Blagdon Code

1040495
1040501

1040518

1040525
1040532

No. Part Description

13
14
15
16
17
18
19
20
21
22
23
24

T connector O ring
Outlet cap
3/4" hose tail
1/2" hose tail
1/2" outlet hose tail
3/4" outlet hose tail
1" flow control valve
Intake cage
Impeller cover
Impeller cover O ring
Impeller complete
Motor

Parts 1-3, 5-8, 10-18 and 20-22 are supplied as one package.

Blagdon Code

1040532

very small pond 2500

Cable Fitted

10 metres

Voltage

230V

Hertz

50Hz

Watts

48

Safety Rating

IP68

Maximum Depth

2.2 metres

Maximum Lift

2.2 metres / 7’2”

1040563
1040549
1040556
N/A

5

Aquagarden 2500.qxd

16/12/10

09:30

Page 9

INSTALLATION
Electrical installation
The power supply must meet the specifications on the product.
The pump is intended to be used with either a weather-proof
cable connector or permanently connected to the fixed wiring
in the main system other than by means of a plug and socket.

INSTALLATION
For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond pump (i.e. local building regulations).

The cores in the supply cable are coloured in accordance with the following
code: Brown = Live, Blue = Neutral, Green/Yellow = Earth.

These pumps must not be used in swimming pools, or areas where people are
in contact with the water.

The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.

Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled. Consult a qualified electrician if in
any doubt about wiring this product to the main supply.

Do not use the supply cable to lift the pump as this may cause damage.

IMPORTANT: Please note all electrical work on garden lighting and
power installations must comply with part P of the building regulations.
Failure to comply is a criminal offence. If the installation of this product
is not carried out by a competent electrician who is registered under the
Part P self-certification scheme then you must notify the local building
control department before work begins. For further information and
guidance on this matter and other electrical installations in your home
that might be covered by the relevant legislation, contact your local
authorities building control department.

WARNING - THIS PUMP MUST BE EARTHED
A Residual Current Device (RCD), also know as the Residual
Current Circuit Breaker (RCCB), with a tripping current not
exceeding 30mA must be installed in the supply circuit.
A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the fixed wiring.

Warning - The pond pump is provided with a thermal
cut out that temporarily switches off the pump in case of
overheating and the pump may automatically restart.
Never run the pump out of water as this may cause irreparable damage.

Locating your Aquagarden pump
The Aquagarden pump should be located on a firm and level base in the
pond/water feature in a depth of at least 10cm, but no more than 2m.
It is advisable to keep the pump off the bottom of the pond to avoid silt
entering the pump causing excessive wear and increasing pre-filter cleaning.

Fountain
Make sure there is ample cable from mains supply. Place pump in desired
location. Add Fountain extension pipes so fountain head is above surface of
the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’
diagram below. See "Getting to know your Aquagarden" for parts and
descriptions.
If using the Daisy or Double Daisy Jet, cleaning of the jets will be reduced by
inserting the optional pre-filter foam included.
Tip: Ensure that any fountain, waterfall, filter or feature fitted does not empty
water out of pond/water feature. In windy conditions it may be necessary to shut
off or reduce the height of your fountain display to prevent water loss. Also see
the explanatory diagram on the top face of your Aquagarden pump carton.

6

7

Aquagarden 2500.qxd

16/12/10

09:30

Page 11

INSTALLATION
ADJUSTING FLOW CONTROL
Turn clockwise to increase,
anti-clockwise to
reduce flow.

BELL FOUNTAIN
Adjust bell by
moving head higher
for small bell and
lower for a wider
bell shape.

MAINTENANCE & CLEANING
Warning - Failure to carry out routine maintenance leaving the
pump under reduced or no flow conditions for long periods
(i.e. blocked pre-filter) will result in a shorter pump life and
will invalidate the guarantee.

Aquagarden 2500 is a centrifugal pump with a magnetic impeller
movement driven by a watertight synchronous motor. They require minimum
cleaning, only periodic cleaning of the pre-filter and impeller is necessary.

Routine Maintenance
Tip: Ensure that any fountain or feature fitted does not empty water out of
pond/water feature. The Bell Jet and Foam Jets do not need the foam pre-filter
so require little maintenance when used with the pre-filter cage only.

Carry out routine maintenance when pump flow is visibly reduced.

Water Feature

3. Remove the front of the pre-filter cage by depressing the button and pulling
apart. Wash the cage thoroughly in fresh water. A blocked pre-filter will
reduce pump flow. Follow steps 1 and 2.

Install as for Fountain. Depending on water feature to be supplied, your pond
pump can be used with the 1/2" hose fitting or 3/4" outlet hose fitting which
can be screwed directly into pump body. Hose clips should be used to secure
hose.
Tip: The larger 1" hose will give maximum performance when fitted.

1. Switch off electricity.
2. Remove pump from pond (do not use the cable to lift the pump).

STEP 1: POND PUMP 2500 (ROUTINE)
Firmly pull pre-filter cage from pump
motor.

STEP 2: POND PUMP 2500 (ROUTINE)
Remove pre-filter foam (if fitted), and
wash thoroughly in fresh water. The
pre-filter is for use with Daisy Jets only.
A blocked foam will reduce the pump
flow rate.

DEPRESS
BUTTON

8

9

Aquagarden 2500.qxd

16/12/10

09:30

Page 13

MAINTENANCE & CLEANING

TROUBLESHOOTING

Monthly Maintenance

Problem

Following as for Routine Maintenance (steps 1 and 2) and then
steps 3, 4 and 5.

Low flow from pump
1. Follow routine cleaning procedure if no improvement.

STEP 3: POND PUMP 2500 (MONTHLY)
Remove impeller
cover by turning
anti-clockwise
to release lock.
Then pull firmly
away from
pump motor
and cage.

STEP 4: POND PUMP 2500 (MONTHLY)
Remove impeller
from pump motor.
Wash parts with
fresh water carefully.

Annual Maintenance
Dismantle pump and examine all parts for wear or damage, replacing any
parts that show obvious wear and/or damage. (See getting to know your pump
for parts/description and replacement parts codes.) Particular care should be
taken to examine the cable entry point and the cable; if there is any sign of
damage the pump should be discarded.

Winter Storage
The pump can be run in the pond during the winter but care should be taken
to ensure that it is fully immersed and cannot freeze solid. If the pump is not
used during the winter, follow annual maintenance procedure and store frostfree in the house or garage until spring.

2. Follow monthly cleaning procedure.
3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed
or kinked.
4. Keep the height that water is to be pumped from the water surface (called
Head) to a minimum. The higher the head the lower the flow rate and the
more wear on the pump.
5. Use the largest diameter, smoothest bore pond hose over the shortest
distance and keep hose fittings to a minimum. This removes frictional loss
of flow and so increases pump flow rates.

Poor Fountain performance
• Reduced height.
• Jets blocked.
Use foam insert with Daisy Jets
for lower maintenance.

DAISY
To clean, remove
head and rinse.
Use optional foam
pre-filter with Daisy
Jet heads.

No flow from pump
1. Check power supply is on.
2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION).
3. Follow low flow procedure as above.
If none of the above works contact Interpet (Blagdon) Consumer Advice
Department (See Faults problem procedure Page 12).

10

11

Aquagarden 2500.qxd

16/12/10

09:30

Page 15

IMPORTANT
FAULTS - PROBLEMS PROCEDURE
Before returning your Aquagarden pump to your dealer or contacting our
Consumer Advice Department, please carry out the following steps.
This will solve most problems quickly and easily.
1. Ensure electrical procedure has been followed fully. Check fuse and any
cable connectors/switch boxes.
NOTE: If the pump has overheated the thermal overload will temporarily
switch off the pump.
2. (a) Follow routine maintenance and check pump. (b) Follow monthly
maintenance and check pump. (c) Follow troubleshooting guide.
(d) Follow annual maintenance guide.
3. Return pump to point of purchase for inspection and advice (You may
need proof of purchase).

Consumer Advice contact details
Interpet (Blagdon) Consumer Advice Department
Vincent Lane, Dorking, Surrey RH4 3YX
Telephone: 0845 226 7437
(Monday to Friday 10am to 4pm except Bank Holidays - Times may vary)
Fax: 01306 876712
E-mail: customercare@interpet.co.uk

12

GUARANTEE
This product is guaranteed against defects in material and workmanship for
2 years from the date of purchase, under normal usage. The guarantee
DOES NOT APPLY in case of improper use, negligence, lack of maintenance
or accidental damage either to the pump or to the impeller or impeller shaft.
If the pump fails due to a manufacturing fault within this period it will be
either repaired or replaced free of charge. Liability is limited to replacement
of the faulty product only, no other costs will be reimbursed.
This guarantee is not transferable and does not affect your statutory rights.
This guarantee does not confer any rights other than those expressly set out
above. Excludes the sponge pre-filter, which should be replaced every six
months and the impeller, which may require replacing annually. If any parts
need replacing, spares are available from your retailer.

Environment friendly disposal
You can help protect the environment.
Please remember to respect the local regulations: hand in the non-working
electrical equipments to an appropriate waste disposal centre.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : Gavin Sadler
Title                           : Aquagarden 2500.qxd
Creator Tool                    : Adobe Illustrator CS3
Create Date                     : 2010:12:16 09:30:42Z
Modify Date                     : 2014:02:26 12:55:13Z
Metadata Date                   : 2014:02:26 12:55:13Z
Thumbnail Width                 : 256
Thumbnail Height                : 228
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 9112 bytes, use -b option to extract)
Document ID                     : uuid:8D1D7D4679FCDF1182EB9EBFD640BEA7
Instance ID                     : uuid:fb354d5b-583f-184c-93e4-c58e71ae3903
Derived From                    : 
N Pages                         : 1
Has Visible Transparency        : False
Has Visible Overprint           : False
Max Page Size W                 : 200.000002
Max Page Size H                 : 50.000000
Max Page Size Unit              : Millimeters
Plate Names                     : Black
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : PANTONE 349 CVC
Swatch Colorant Type            : SPOT
Swatch Colorant Tint            : 100.000000
Swatch Colorant Mode            : CMYK
Swatch Colorant Cyan            : 100.000000
Swatch Colorant Magenta         : 0.000000
Swatch Colorant Yellow          : 83.137253
Swatch Colorant Black           : 47.058823
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Page Count                      : 8
Author                          : Gavin Sadler
EXIF Metadata provided by EXIF.tools

Navigation menu