Aquagarden 2500 Pond Pump
2017-05-31
: Aquarium Aquagarden-Pond-Pump-2500 Aquagarden-Pond-Pump-2500 s
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Aquagarden 2500.qxd 16/12/10 09:30 Page 1 Produced exclusively by GUIDE TO Established over 40 years ago, Blagdon are committed to producing a comprehensive range of high quality, easy to use, pond equipment. An ongoing programme of research and development ensures excellent performance and value for all their customers. This product excellence is demonstrated by Blagdon’s award winning range of water gardening equipment. As a result Blagdon’s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike. Blagdon - The Pond Masters The name you can rely on www.aquagarden-range.co.uk Interpet, Vincent lane Dorking, Surrey, RH4 3YX Leaflet Code: AG PUMPS 2-a Aquagarden for Fountains, Filters and Waterfalls 2500 THE POND MASTERS GUIDE TO Aquagarden 2500.qxd 16/12/10 09:30 Page 3 GUIDE TO Aquagarden pond for Fountains, Filters and Waterfalls 2500 Congratulations on buying an Aquagarden Pond pump fountains filters and waterfalls Fountain and Water Feature Pump. Aquagarden pumps are high quality pumps manufactured with advanced technology, to run pond fountains filters and waterfalls. The powerful motors are easy to maintain having a single moving part impeller system featuring highly wear-resistant ceramic shaft design. IMPORTANT Please attach proof of purchase to this manual and file in a safe place. 1 Aquagarden 2500.qxd 16/12/10 09:30 Page 5 CONTENTS GETTING TO KNOW YOUR AQUAGARDEN PUMP Getting to know your Aquagarden pump 3 Parts descriptions / spares codes - with exploded diagram 4 Technical specifications 5 Pump performance / flow chart 5 Installation 6 Electrical installation 6 Installing pump in pond 7 Maintenance and cleaning 9 Cleaning Step by step guides 9 9-10 Routine maintenance 9 Monthly maintenance 10 Annual maintenance 10 Winter storage 10 Troubleshooting 11 Troubleshooting and maximise performance 11 Faults - problem procedure 12 Returning faulty pumps 12 Consumer advice contact details 12 Guarantee 13 2 3 Aquagarden 2500.qxd 16/12/10 09:30 Page 7 GETTING TO KNOW YOUR AQUAGARDEN PUMP GETTING TO KNOW YOUR AQUAGARDEN PUMP 6 POND PUMP 2500 Pump performance / flow chart 5 9 7 8 12 14 17 18 19 15 1 4 20 10 16 21 23 13 11 POND PUMP very small pond 2500 Lift Flow rates lph 2.0 metres 240 lph 1.5 metres 800 lph 1.0 metres 1200 lph 0.5 metres 1640 lph 0.0 metres 2200 lph Flow is given as optimum rate 2 22 Technical Specification & Performance 24 POND PUMP 3 For spares for your Aquagarden product select compatible Blagdon spare part numbers No. Part Description 1 2 3 4 5 6 7 8 9 10 11 12 4 Pre-filter cage front Pre-filter cage back Pre-filter cage insert base Foam pre-filter Double daisy jet Daisy jet Bell jet Foam jet 20 cm extension Fountain T piece T connector Fountain flow control Blagdon Code 1040495 1040501 1040518 1040525 1040532 No. Part Description 13 14 15 16 17 18 19 20 21 22 23 24 T connector O ring Outlet cap 3/4" hose tail 1/2" hose tail 1/2" outlet hose tail 3/4" outlet hose tail 1" flow control valve Intake cage Impeller cover Impeller cover O ring Impeller complete Motor Parts 1-3, 5-8, 10-18 and 20-22 are supplied as one package. Blagdon Code 1040532 very small pond 2500 Cable Fitted 10 metres Voltage 230V Hertz 50Hz Watts 48 Safety Rating IP68 Maximum Depth 2.2 metres Maximum Lift 2.2 metres / 7’2” 1040563 1040549 1040556 N/A 5 Aquagarden 2500.qxd 16/12/10 09:30 Page 9 INSTALLATION Electrical installation The power supply must meet the specifications on the product. The pump is intended to be used with either a weather-proof cable connector or permanently connected to the fixed wiring in the main system other than by means of a plug and socket. INSTALLATION For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump (i.e. local building regulations). The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral, Green/Yellow = Earth. These pumps must not be used in swimming pools, or areas where people are in contact with the water. The electric cable is permanently connected and sealed in the motor body. If the supply cable is damaged the pump must not be used. Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the main supply. Do not use the supply cable to lift the pump as this may cause damage. IMPORTANT: Please note all electrical work on garden lighting and power installations must comply with part P of the building regulations. Failure to comply is a criminal offence. If the installation of this product is not carried out by a competent electrician who is registered under the Part P self-certification scheme then you must notify the local building control department before work begins. For further information and guidance on this matter and other electrical installations in your home that might be covered by the relevant legislation, contact your local authorities building control department. WARNING - THIS PUMP MUST BE EARTHED A Residual Current Device (RCD), also know as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring. Warning - The pond pump is provided with a thermal cut out that temporarily switches off the pump in case of overheating and the pump may automatically restart. Never run the pump out of water as this may cause irreparable damage. Locating your Aquagarden pump The Aquagarden pump should be located on a firm and level base in the pond/water feature in a depth of at least 10cm, but no more than 2m. It is advisable to keep the pump off the bottom of the pond to avoid silt entering the pump causing excessive wear and increasing pre-filter cleaning. Fountain Make sure there is ample cable from mains supply. Place pump in desired location. Add Fountain extension pipes so fountain head is above surface of the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below. See "Getting to know your Aquagarden" for parts and descriptions. If using the Daisy or Double Daisy Jet, cleaning of the jets will be reduced by inserting the optional pre-filter foam included. Tip: Ensure that any fountain, waterfall, filter or feature fitted does not empty water out of pond/water feature. In windy conditions it may be necessary to shut off or reduce the height of your fountain display to prevent water loss. Also see the explanatory diagram on the top face of your Aquagarden pump carton. 6 7 Aquagarden 2500.qxd 16/12/10 09:30 Page 11 INSTALLATION ADJUSTING FLOW CONTROL Turn clockwise to increase, anti-clockwise to reduce flow. BELL FOUNTAIN Adjust bell by moving head higher for small bell and lower for a wider bell shape. MAINTENANCE & CLEANING Warning - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods (i.e. blocked pre-filter) will result in a shorter pump life and will invalidate the guarantee. Aquagarden 2500 is a centrifugal pump with a magnetic impeller movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the pre-filter and impeller is necessary. Routine Maintenance Tip: Ensure that any fountain or feature fitted does not empty water out of pond/water feature. The Bell Jet and Foam Jets do not need the foam pre-filter so require little maintenance when used with the pre-filter cage only. Carry out routine maintenance when pump flow is visibly reduced. Water Feature 3. Remove the front of the pre-filter cage by depressing the button and pulling apart. Wash the cage thoroughly in fresh water. A blocked pre-filter will reduce pump flow. Follow steps 1 and 2. Install as for Fountain. Depending on water feature to be supplied, your pond pump can be used with the 1/2" hose fitting or 3/4" outlet hose fitting which can be screwed directly into pump body. Hose clips should be used to secure hose. Tip: The larger 1" hose will give maximum performance when fitted. 1. Switch off electricity. 2. Remove pump from pond (do not use the cable to lift the pump). STEP 1: POND PUMP 2500 (ROUTINE) Firmly pull pre-filter cage from pump motor. STEP 2: POND PUMP 2500 (ROUTINE) Remove pre-filter foam (if fitted), and wash thoroughly in fresh water. The pre-filter is for use with Daisy Jets only. A blocked foam will reduce the pump flow rate. DEPRESS BUTTON 8 9 Aquagarden 2500.qxd 16/12/10 09:30 Page 13 MAINTENANCE & CLEANING TROUBLESHOOTING Monthly Maintenance Problem Following as for Routine Maintenance (steps 1 and 2) and then steps 3, 4 and 5. Low flow from pump 1. Follow routine cleaning procedure if no improvement. STEP 3: POND PUMP 2500 (MONTHLY) Remove impeller cover by turning anti-clockwise to release lock. Then pull firmly away from pump motor and cage. STEP 4: POND PUMP 2500 (MONTHLY) Remove impeller from pump motor. Wash parts with fresh water carefully. Annual Maintenance Dismantle pump and examine all parts for wear or damage, replacing any parts that show obvious wear and/or damage. (See getting to know your pump for parts/description and replacement parts codes.) Particular care should be taken to examine the cable entry point and the cable; if there is any sign of damage the pump should be discarded. Winter Storage The pump can be run in the pond during the winter but care should be taken to ensure that it is fully immersed and cannot freeze solid. If the pump is not used during the winter, follow annual maintenance procedure and store frostfree in the house or garage until spring. 2. Follow monthly cleaning procedure. 3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed or kinked. 4. Keep the height that water is to be pumped from the water surface (called Head) to a minimum. The higher the head the lower the flow rate and the more wear on the pump. 5. Use the largest diameter, smoothest bore pond hose over the shortest distance and keep hose fittings to a minimum. This removes frictional loss of flow and so increases pump flow rates. Poor Fountain performance • Reduced height. • Jets blocked. Use foam insert with Daisy Jets for lower maintenance. DAISY To clean, remove head and rinse. Use optional foam pre-filter with Daisy Jet heads. No flow from pump 1. Check power supply is on. 2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION). 3. Follow low flow procedure as above. If none of the above works contact Interpet (Blagdon) Consumer Advice Department (See Faults problem procedure Page 12). 10 11 Aquagarden 2500.qxd 16/12/10 09:30 Page 15 IMPORTANT FAULTS - PROBLEMS PROCEDURE Before returning your Aquagarden pump to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedure has been followed fully. Check fuse and any cable connectors/switch boxes. NOTE: If the pump has overheated the thermal overload will temporarily switch off the pump. 2. (a) Follow routine maintenance and check pump. (b) Follow monthly maintenance and check pump. (c) Follow troubleshooting guide. (d) Follow annual maintenance guide. 3. Return pump to point of purchase for inspection and advice (You may need proof of purchase). Consumer Advice contact details Interpet (Blagdon) Consumer Advice Department Vincent Lane, Dorking, Surrey RH4 3YX Telephone: 0845 226 7437 (Monday to Friday 10am to 4pm except Bank Holidays - Times may vary) Fax: 01306 876712 E-mail: customercare@interpet.co.uk 12 GUARANTEE This product is guaranteed against defects in material and workmanship for 2 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage either to the pump or to the impeller or impeller shaft. If the pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only, no other costs will be reimbursed. This guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. Excludes the sponge pre-filter, which should be replaced every six months and the impeller, which may require replacing annually. If any parts need replacing, spares are available from your retailer. Environment friendly disposal You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal centre.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Gavin Sadler Title : Aquagarden 2500.qxd Creator Tool : Adobe Illustrator CS3 Create Date : 2010:12:16 09:30:42Z Modify Date : 2014:02:26 12:55:13Z Metadata Date : 2014:02:26 12:55:13Z Thumbnail Width : 256 Thumbnail Height : 228 Thumbnail Format : JPEG Thumbnail Image : (Binary data 9112 bytes, use -b option to extract) Document ID : uuid:8D1D7D4679FCDF1182EB9EBFD640BEA7 Instance ID : uuid:fb354d5b-583f-184c-93e4-c58e71ae3903 Derived From : N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 200.000002 Max Page Size H : 50.000000 Max Page Size Unit : Millimeters Plate Names : Black Swatch Group Name : Default Swatch Group Swatch Group Type : 0 Swatch Colorant Swatch Name : PANTONE 349 CVC Swatch Colorant Type : SPOT Swatch Colorant Tint : 100.000000 Swatch Colorant Mode : CMYK Swatch Colorant Cyan : 100.000000 Swatch Colorant Magenta : 0.000000 Swatch Colorant Yellow : 83.137253 Swatch Colorant Black : 47.058823 Producer : Acrobat Distiller 8.1.0 (Macintosh) Page Count : 8 Author : Gavin SadlerEXIF Metadata provided by EXIF.tools