Aram Huvis APMPRO APM-PRO User Manual APM pro manual 1130

Aram Huvis Co.,LTD. APM-PRO APM pro manual 1130

User manual

User Manual
ContentH/W PartsSystem SettingsApplication345678910111214151617181921232426WarrantyComponentsTroubleshooting & FAQDate & TimeWi-Fi Application SettingsCRM - FullCRM - SimpleHydrationSebumPoreMelaninAcneWrinkleHemoglobinResultSend Result -EmailSend Result - MirroringDevice FunctionsDevice Settings
ComponentsComponents3Main unit with skin lens (APM PRO)ChargerSkin tone sensor(ST model only)Cleaning cloth ManualUSB cableSebum paper 2 box Air blowerLens cap 2eaCradle
4APM PRO lensIndicate LEDLens module change buttonUSB slot (DC 5V 3A)On/off buttonX1 LensFlashFlash buttonVolume up & down buttonDevice Functions H/W Parts
To turn on & off the powerPress and hold “power” button.Then “Indicate LED” will be twinkled and turned on white.12Device SettingsB. H/W Parts 5Charger can be used for Amercian type & European type. The default is European type. 21Push the plug up.1Then 220V European type is disassembledand you can see the 110V-220VAmerican type inside of the charger.23Choose the one you want to use and connect USB cable in adaptor.
 6Date & TimeSystem Settings Touch “Date & time”.Touch “Set date”. Please check the settingis correctly applied.Press      button.2Change the date andtouch “OK” button.Touch       button.2 34 5 61
System Settings 7Wi-FiTouch “Wi-Fi”. Turn on toggle switch.Touch       button.Wi-Fi list will be appeared.Among the lists, select the Wi-Fi connection you could use.Wait until the device is connected to with Wi-Fi.1 2 34 5 6
2Touch "SETTINGS".22Language, version, email setting is available.1Press      button.8ApplicationApplication Settings1 23
Touch "START DIAGNOSIS".1If you are new customer, touch “NEW CUSTOMER”.3Input the information as below.- Full Name, phone number, email address.- Gender and age group.Touch "FULL DIAGNOSIS".After registering all information, touch “SAVE” button.Check the diagnosis menu and touch "OK".CRM -  FullApplication91 2 34 5 6
Touch “SIMPLE DIAGNOSIS” button.1Select the “GENDER” and “AGE” group. 2“START DIAGNOSIS” 10CRM - SimpleApplication1 23
Check the result.21Application11Hydration1 2Touch the  “SCAN” button. After beep sound, place the sensor on the skin. And hold it for 3~4 seconds until vibration and sound.
Put the sebum paper(pink area)  onto the U-zone of your face for seconds.Put the sebum paper (pink area) onto the T-zone of your face for seconds.Touch     to take picture the pink area only.Touch              to activate camera.Touch        to activate camera. Touch     to take picture the pink area only.12ApplicationSebum1 24 536
Touch “SCAN” to measure.Check the result.Touch the “SKIN TYPE” button.8SebumApplication136 78
Touch        to activate camera. Place the lens onto your skin and touch       button.    Touch “SCAN ”  to analyze. Check the result. 14PoreApplication13 42
Touch        to activate camera.Touch “SCAN”   to analyze. Check the result.Place the lens onto your skin and touch       button.    Application15Melanin13 42
Touch “SCAN”   to analyze. Check the result.Touch        to activate camera. Place the lens onto your skin and touch       button.    16ApplicationAcne13 42
Touch “SCAN ”   to analyze. Check the result.Move the white box and touch “SAVE” button.                       Touch        to activate camera. Place the lens onto your skin and touch       button.    WrinkleApplication174 51 32
Touch “SCAN ”   to analyze. Check the result.Touch        to activate camera. Place the lens onto your skin and touch       button.     18 HemoglobinApplication13 42
Available to check the diagnosis result.Product recommendation.Touch “ELASTICITY” or “HYDRATION”. Touch “Diagnosis”.Application19Result1 23 4
    means the worst status in your diagnosis result.    - Main concern.Touch each parameter you wantto check “skin image’ & ”product”Touch ”Pore” or “Melanin” or etc you want to check .Available to check the diagnosis result.Available to check “product image”.1 220ApplicationResult3 4 5
After select the mail account, please Input the ID only and password. Then touch “OK”.Select the mail account to register on the list.In SETTINGS page, touch “7.Email setting”.Touch “Mail account”Send Result - EmailApplication211 23 4
Press    button. Touch     button. Touch “Wireless & networks”Check the square box.In “Send result” page, touch “Email”. 22Send Result - EmailApplication34 5 6“Receiver”s email address will be appeared with your CRM information. Otherwise, input the email address.21
Touch "SETTINGS".Press    button.It is able to connect to “Android Viewer” & “iOS  Viewer” system  when AP  success is shown up on the screen.With your mobile device, capture QR code. Then program will be installed.In your mobile device go to Wi-Fisetting. Then find "ARAMHUVIS" code and connect it.Mirroring system is started.Application23Send Result - Mirroring34215 6
24Troubleshooting & FAQI cannot turn on the device.Connect and charge the device (or the battery) using the adaptor provided the supplier.(The battery charging indicator will be shown on the system main page.)1I cannot  power on the device even the battery is still full.The battery might be dislocated on the device. Please separate the battery from the device and put it on, and then power on again.2The battery is not charging very well.Separate the battery from the device and put it on again.Check the connection among a device, a battery and a charger.A battery cannot be charged if there is an alien substance on the charging port. In this case, please use the device aer cleaning the charging port of the device or check whether the sticker is attached on charging port.3The using time of the battery is dierent from the manual.The battery using time  will be shorten if you put the charged battery in a low or high temperature.The battery using time varies in service type, using environment, using period of the battery.The battery is consumed without using the  device, and the battery using time will be shorten if you use additional functions of the device.4The device turns on but the diagnosis doesn’t work.Check the smart card is correctly inserted (SD card slot on the button of the device.)5There are dust on the device.Clean the dust by using a smooth fabric. Do not use bemzene, alcohol, and a synthetic detergent.6The screen is frozen and the keys not working when using the device.Separate the battery from the device and put it on again.If the device is still not working please contact to the customer servise center.7A “force close” message appears on the screen.The repetition of commands can trigger a bug. Sometimes there may be a brief delay before the command is completed. Do not repeat/multiply the tasks as the device will no longer be able to follow them.8I cannot connect to Wi-Fi.Check the connection status on setting page.Try to connect to another Wi-Fi.Bluetooth : check the pairing status and try to re-pair the device with host device.9
Troubleshooting & FAQ25The touchscreen doesn’t react to my finger commands.Before using for the first time remove the protective plastic film.10I cannot connect to Blue-tooth.Make sure to use the Bluetooth hosting devices that have Bluetooth certified with the logo. You may need an external Bluetooth dongle for those devices that do not have Bluetooth feature. bring the device to closer with the Bluetooth hosting device.Try to re-pair the device with host device.The password of pairing is “0”(number).* Blue-tooth function is not allowed to use in IOS device without APPLE’S oicial permission.11The screen was turned o.Press the on/o button to turn on the screen.The device has a power save function that turn the screen o aer 1minute.For the setting, please refer to Page 8.12I can see the black screen only during measurement.Check the LED light inside lens on the  head part when you try to measurement.If you cannot see the light, please contact the customer service via email or phone call.13The image is not clear.Tap the screen while capturing focus.14I cannot update the diagnsis application.Check the network connection. The update process can be done aer connecting to Wi-Fi.15
 26WarrantyThe product undergoes strict quality management and inspection process before production and introduction to market.1In case of functional or operational defect occurs under normal condition of use within 10 days aer purchase, we will repair it for free or replace in new product.2When this product goes out under the normal use, we will repair it free of charge under warranty. 3Please keep the warranty card when you ask for repair service.4Customer needs to pay repair charge aer warranty runs out.5For this product, warranty period is 14 months from the Invoice date.6Cost Within warranty : Sending delivery(Buyer), repair cost and returning delivery(Aram)         - If the product is broken by user's fault, repair cost could be charged.         Aer warranty : Sending delivery and repair cost(Buyer), returning delivery(Aram)7How to send :        - As sending a present from person to person by EMS or FEDEX.         (Do not write the company name)               - Total value should be under US $ 99.(Write non-commercial value)8
Service request formDate of purchaseContact personAddress :Tel :Product name, serial No : Problems : Company /               / PRODUCTION DIVISION & FACTORY (SHIPPING ADDRESS) :#909 Byucksan Technopia, 560, Dunchon-daero, Jungwon-gu, Seongnam-si, Gyeonggi-do, 13230 Rep. KoreaTel: 070-4687-1712  /  Fax: 031-732-6330  /  Email: support@aramhuvis.comhttp://www.aramhuvis.com 27Warranty
FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   FCC Interference Statement   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver.   • Connect the equipment into an outlet on a circuit different from which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.   FCC Caution   Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Radiation Exposure Statement   IEEE 802.11b or 802.11g operation of this product in the USA is firmware-limited to channels 1 through 11.   If the device is going to be operated in the 5.15 - 5.25 frequency range, then it is restricted to indoor environment only. This device meets all other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
 HEAD OFFICEJung-Ja Dong-Rm401-402, Seoul National University Hospital’s Health Care Innovation Park, 172, Dolma-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13605 Rep. KoreaPRODUCTION DIVISION & FACTORY#909 Byucksan Technopia, 560, Dunchon-daero, Jungwon-gu, Seongnam-si, Gyeonggi-do, 13230 Rep. KoreaTel: 070-4687-1712  /  Fax: 031-732-6330  /  Email: info@aramhuvis.comhttp://www.aramhuvis.com

Navigation menu