Ascensia Diabetes Care US CGMM01 CGMM01 User Manual

Bayer HealthCare Diabetes Care CGMM01

User Manual

CGM Quick Reference Guide   Power/back buttonFront buttonsUSB plugHome screenTest strip port USB capCGM System: Monitor FeaturesCGM System: Monitor Charging Charge your monitor every day.1.  Remove the protective cap from the      USB plug on the monitor.2.  Insert the monitor's USB plug into       the wall adapter.3.  Plug the wall adapter into an outlet.              - The orange light on the test strip         port will blink while it is charging.         - The light will turn off after it has         a full charge.CGM System: Pairing the Monitor and Transmitter1.  Press and hold the power/back button      for 2 seconds to turn on the monitor.2.  Lift to remove the fully charged       transmitter from its charging unit.3.  Wait for the monitor to find the      transmitter (it may take as long as      one minute).5.  Wait for the monitor to connect to      the transmitter.4.  Use the UP and DOWN buttons to      find the number on the monitor      screen that matches the number on      the top of the charged transmitter,      and press OK.12Warnings: This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
  CGM Quick Reference Guide    2707511:32 AM 1:32 PM mg/dL118    34CGM System:  Wearing a Sensor Use the monitor screens to help guide you.1.  Remove the sensor guide from its      sterile packaging and insert the       transmitter into its slot in the       sensor guide.2.  Turn the sensor assembly over and      remove the adhesive liner before       putting the sensor assembly on      your skin.3.  Insert the sensor (a CLICK sound      means the sensor was inserted).      Once you have inserted a new sensor, you must wait 1 hour for the sensor to stabilize before you can calibrate it.CGM System:  Calibrating a Sensor In order for the monitor to properly display your glucose levels, it must be calibrated with fingertip testing at least every 12 hours.1.   Choose to calibrate now or later.       - If you are ready to calibrate,         press YES and insert a test trip.2.   After performing a prick of the tip of        your finger, touch the tip of the test       strip to the drop of blood and hold it        there until the monitor beeps and        shows "Accepted"3.   Read your fingertip test result.       - If you want to use this result to          calibrate your monitor, press YES.         If you do not wish to use it to calibrate,         press NO.4.  Your continuous glucose reading will      appear on the Home screen within 5       minutes of calibrating.Warnings: This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible  for compliance could void the user's authority to operate this equipment.

Navigation menu