400-140-000-C (TH140-28) ENG.fm Page 1 Tuesday, January 15, 2008 1:46 PM TH140-28 Installation and User Guide Electronic Programmable Thermostat n Installation 1. 1.2 Thermostat Wiring 1.1 Guidelines TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. NORTH AMERICA LOW VOLTAGE < 30 V: no polarity Installation should be carried out by an electrician. 120/240 V • For a new installation, choose a location about 5 ft. (1.5 m) above the floor. • The thermostat must be installed facing the heating system and on an inside wall. Connection to a circulator through a 24 V relay Relay • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes. 24 V transformer Relay Connection to the thermostat terminals of a furnace Furnace LINE VOLTAGE 120 to 240 VAC Must be installed onto a certified electrical box. Power supply 2 A maximum load 120/240 V n o Loosen the captive screw holding the faceplate to the mounting plate. Pull the lower part of the faceplate to remove it from the mounting plate. p Loosen the screw (captive) holding the wire cover and remove the wire cover. q Pull wires through the hole in the mounting plate and secure the mounting plate to the wall (or onto an electrical box for line voltage wiring) using the enclosed wall anchors and screws. r Wire the thermostat to the heating system (see section 1.2) and, if necessary, connect the remote input (see section 1.3). s t Once wiring is complete, re-install the wire cover. u v Connection to a circulator (pump) of a water heating system Load Provided wires EUROPE For a 2-wire connection: no polarity 240 V Relay Connection to the thermostat terminals of a furnace Use the switches located at the back of the faceplate to configure your thermostat (see section 1.4) according to your application. Install the batteries (see section 1.5). Direct wiring to the circulator Furnace For a 3-wire connection: observe the polarity Mount the faceplate on the mounting plate and tighten the screw. 240 V TH140-28 400-140-000-C Wiring to a power-operated mixing control valve 2008-01-15 1/4 400-140-000-C (TH140-28) ENG.fm Page 2 Tuesday, January 15, 2008 1:46 PM 1.3 Remote Input Wiring Heating Cycle Selection (switches #1 and #2) The TH140 is equipped with a remote input which allows connection of a telephone controller (optional Aube CT240), a home automation system or any other remote control system. When a signal is received through this input, the TH140 will automatically switch from normal operating mode to Vacation mode, or vice versa when the signal is removed. Select the cycle using switches #1 and #2. Short cycles help eliminate temperature variations, thus increasing user comfort. Since shorter cycles can lead to premature system wear, it is important to select the temperature control cycles appropriate to your heating system. In general, the bigger your heating unit is, the longer the cycles should be. 1.3.1 Connection to the CT240 Connect CT240 terminals A and C to TH140 terminals X and C. You must respect the polarity. For details on operating the telephone controller, refer to the instruction manual. Cycles EUROPE AMERICA 5 minutes Not recommended for furnaces Not recommended for central units 10 minutes Gas or electric wall furnace Radiant or convection electric heating 15 minutes Fuel or gas floor furnace, forced air heating Central heating 1.3.2 Connection to a home automation system Connect the TH140 to the home automation system as displayed in the wiring diagram. Home automation system 20 minutes Position Commercial unit 1.4 Configure the Thermostat The switches are located on the back of the faceplate. Default settings are highlighted. 1.4.2 Conventional mode with anticipation (switch #5) This mode is compatible with all heating systems. Programmable Span Selection (switches #1 and #2) Switch 1&2 Description UP DOWN Cycles (proportional) 15 min (see 1.4.1) Span (conventional) 0.5°C (0.9°F) (see 1.4.2) 3 Clock display 12H 24H 4 Temperature display 1 °F °C 5 Temperature control mode Proportional (see 1.4.1) Conventional (see 1.4.2) 6 Pump protection 2 Deactivate Activate Select the span using switches #1 and #2. The default temperature span is 0.5°C (0.9°F). For example, if the temperature setpoint is 20°C (68°F), the heating system will turn on at 19.5°C (67.1°F) and turn off at 20.5°C (68.9°F). Span 0,3°C (0,5°F) Hot Water Heating 0,4°C (0,7°F) Gas or electric wall furnace 1.4.1 Proportional Adaptive Mode (switch #5) 0,5°C (0,9°F) Fuel or gas floor furnace 0,6°C (1,1°F) 1. Position Not recommended for Not recommended for furnaces central units 1. If you change from °C to °F (or vice versa), you will need to reprogram your Comfort, Economy and Vacation settings. 2. For hot water installations, it is recommended to enable this option to activate the pump for one minute every 24 hours to prevent pump seizure. This mode analyzes previous cycles to define the the next duty cycle. This control mode guarantees optimal temperature control based on the system’s capacity. To extend the life of the system, a minimum On/Off time of 10% of the cycle has been implemented. For example with a 15-minute cycle, the system would not start or stop for less than 1.5 minutes. Forced Air Heating Radiant or convection electric heating 1 Central heating Commercial unit 240 volt heating with relay (baseboard, convector, radiant ceiling, etc.) Ideal for: • Radiant or convection electrical heating system • Circulator control in a hot water system • Electrical hot-air furnace • Conventional gas or fuel hot-air furnace Not recommended for: • Gas or fuel furnace or boiler with a wall chimney having a 30-second or higher combustion gas purging cycle. To figure out the gas purging cycle of your system, count the time between the heating command sent by the thermostat and the moment when the burner actually goes on. • Multi-zone systems, where several thermostats command a single heating unit. Note: In these last two cases, conventional mode with anticipation is recommended. TH140-28 400-140-000-C 2008-01-15 2/4 400-140-000-C (TH140-28) ENG.fm Page 3 Tuesday, January 15, 2008 1:46 PM 1.5 Install the Batteries p When you first install the batteries, the unit runs a sequence of tests and a complete reset to zero. The screen should display 0:00 MO and the ambient temperature. The current setpoint is 20°C. 3.1 Automatic This mode executes the schedule. To activate: • Press Manual/Auto until setpoint icon is displayed. 1.5.1 Replacing the batteries When in Automatic mode, you can temporarily bypass the current program setpoint until the beginning of the next program. To bypass: The time and programming are saved for 15 seconds when replacing the batteries. • Set the desired temperature use a pre-defined setpoint. 2. Note: You may program the thermostat while holding it in your hands or when it is mounted on the mounting plate. Set the day, using the Day button. 3.3 Vacation or to use Maintains a specific temperature when away for a prolonged absence (e.g. vacation). 2.2.1 Comfort and Economy These setpoints are associated to the schedule’s programs and are pre-programmed as follows: Comfort 20°C (68°F) Programs 1 and 3 Economy 18°C (64°F) Programs 2 and 4 2.2.2 Vacation This pre-programmed setpoint is used when the Vacation mode is activated. 10°C (50°F) 2.2.3 To Modify a Setpoint Set the temperature using to is displayed. • Set temperature OR quickly press a pre-defined setpoint. Vacation or This mode allows you to maintain a constant temperature. To activate this mode: Set the time, using the Hour and Minute buttons. 2.2 Configure the Setpoints n o OR quickly press 3.2 Manual • Press Manual/Auto until 2.1 Set the Time and Day n o is displayed. The program 3.1.1 Temporary Bypass The TH140 will display an icon indicating that the batteries must be replaced. This icon will be displayed for 60 days; after this delay, the TH140 will shut down the heating unit. o 3. The TH140 offers three operating modes: The ambient temperature could be higher if you are holding the TH140 in your hands. It will return to normal about one hour after installation. Basic Configuration Select the Operating Mode . Press and hold one of the setpoint buttons ( or or ) until the icon is displayed on the screen (approx. 3 seconds). 2.3 View the Current Setpoint To view the current setpoint, quickly press once one of the arrow buttons . The screen displays the setpoint; the arrow indicates a setpoint. • From the TH140, quickly press to activate. • Can also be activated remotely (CT240, home automation system or any other system) if the remote input is connected to one of these systems. Note: When the Vacation mode is activated remotely, it can only be deactivated remotely. Note: For details on how to activate the Vacation mode using a telephone, refer to the CT240 Instruction Manual. q Program Your Schedule 4. The TH140 allows four setting changes for each day of the week. There are no pre-set programs. Your heating system switches betwwen the Comfort setpoint and the Economy setpoint according to the times you would have set. For example, enter each day the time at which you wake up (PROG 1), the time you leave for work (PROG 2), the time you return home (PROG 3) and the time you go to bed (PROG 4): Programs Associated Setpoint Time PROG 1 (Comfort) Wake-up PROG 2 (Economy) Leave PROG 3 (Comfort) Return PROG 4 (Economy) Sleep Note: For temperature increases (PROG 1 and 3), allow at least 15 minutes per 1°C (2°F). For example, if you have lowered the temperature by 3°C (6°F) while you sleep and you wake up at 7 a.m., change the setting at 6:15 a.m. TH140-28 400-140-000-C 2008-01-15 3/4 400-140-000-C (TH140-28) ENG.fm Page 4 Tuesday, January 15, 2008 1:46 PM 4.1 Set or Modify the Programs • After 60 seconds of inactivity, the thermostat will automatically exit programming mode. • It is sometimes faster to program the same schedule for the entire week and then modify the exception days. n o Press Program. The screen displays MO and PROG 1. Press Day to select the day (hold for 3 seconds to select all days of the week). p Press Hour and Minute to set the start time. To clear an entry, press Clear, the time zone displays --:-- when the program is inactive. q r s Press Program to select the program number (2, 3 or 4). Repeat steps 3 and 4 for remaining programs. Press Manual/Auto to exit. 4.1.1 Programming Example Comfort (programs 1 and 3): • Monday to Friday between 6:00 a.m. and 8:30 a.m. and between 4:00 p.m. and 11:00 p.m. • Saturday and Sunday between 6:00 a.m. and 11:00 p.m. Economy (programs 2 and 4): • Monday to Friday between 8:30 a.m. and 4:00 p.m. and between 11:00 p.m. and 6:00 a.m. • Saturday and Sunday between 11:00 p.m. and 6:00 a.m. PROG MON TUE WED THU FRI SAT SUN 1 6:00 6:00 6:00 6:00 6:00 6:00 6:00 2 8:30 8:30 8:30 8:30 8:30 --:-- --:-- 3 PM 4 PM 4:00 11:00 PM PM 4:00 11:00 PM PM 4:00 11:00 PM PM 4:00 11:00 PM PM 4:00 11:00 --:-PM 11:00 --:-PM 11:00 To program this schedule: n o Press Program. The screen displays MO and PROG 1. p Set the time (6:00) for the first program (PROG 1) using the Hour and Minute buttons. q Press Program to select PROG 2. Set the time (8:30) using the Hour and Minute buttons. r Press Program to select PROG 3. Set the time (4:00 p.m.) using the Hour and Minute buttons. s Press Program to select PROG 4. Set the time (11:00 p.m.) using the Hour and Minute buttons. t Press Manual/Auto to exit. Press and hold Day for 3 seconds to select all days of the week (MOTUWETHFRSASU). 5. Power supply: 2 AA or LR6 alkaline batteries 1.5 V Max. resistive load: 5 A @ 240 VAC / 5 A @ 30 VDC Max. inductive load: 2 A @ 240 VAC / 2 A @ 30 VDC (P.F. = 0.4) Remote input: 12 VDC, ± 10%, 2.5 mA Certifications: CE, c UL us Control device: Electronic Automatic action: Type 1 B Number of programs: 4 programs / day, total of 28 programs Storage temperature: -20°C to 50°C (-4°F to 122°F) Operating temperature: 0°C to 50°C (32°F to 122°F), 95% R.H. Temperature setting range: 5°C to 30°C (40°F to 85°F) Temperature display resolution: 0.1 degree Temperature reading accuracy: ± 0.5°C (± 0.9°F) Software: Class A Protection class: II Protection degree: IP 40 The terminals are designed to handle a cross-section of wire measuring up to 2.5 mm2 (14 AWG). ; Warranty 6. Aube warrants this product, excluding battery (if applicable), to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from province or state to another. Technical Assistance 7. 705 Montrichard Saint-Jean-sur-Richelieu Québec, Canada J2X 5K8 10 rue Ampère 95500 Gonesse France Press Program to access programming mode. Tel. : (450) 358-4600 33 (0) 1 34 07 99 00 Press Program until PROG 2 is selected. 1-800-831-AUBE 33 (0) 1 34 07 99 19 Press Day to select SAturday (SA). Fax : (450) 358-4650 advaube@comintes.com To erase programs 2 and 3 for Saturday and Sunday: n o p q r s t u r Technical Specifications Press Clear to erase the time (--:--). Press Day to select SUnday (SU). Press Clear to erase the time (--:--). aube.service@honeywell.com For more information on our products, visit us at www.aubetech.com Repeat steps 2 to 5 for PROG 3. Press Manual/Auto to exit. TH140-28 400-140-000-C 2008-01-15 4/4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:01:15 13:55:41-05:00 Create Date : 2008:01:15 13:51:07-05:00 Metadata Date : 2008:01:15 13:55:41-05:00 Format : application/pdf Title : 400-140-000-C (TH140-28) ENG.fm Creator : e283638 Document ID : uuid:79c4d2f4-102d-4699-8664-7630624af740 Instance ID : uuid:6c916c4d-bcf7-466b-a6d5-1ad1c34d2996 Page Count : 4 Author : e283638EXIF Metadata provided by EXIF.tools