Aube Technologies Th140 28 Users Manual 400 140 000 C (TH140 28) ENG

TH140-28 to the manual ec434d5f-8b90-482d-829d-3fd95dccbbb6

2015-02-06

: Aube-Technologies Aube-Technologies-Th140-28-Users-Manual-500643 aube-technologies-th140-28-users-manual-500643 aube-technologies pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

TH140-28 400-140-000-C 2008-01-15 1/4
1.1 Guidelines
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
Installation should be carried out by an electrician.
For a new installation, choose a location about 5 ft. (1.5 m) above
the floor.
The thermostat must be installed facing the heating system and on
an inside wall.
Avoid locations where there are air drafts (top of staircase, air out-
let), dead air spots (behind a door), direct sunlight or concealed
chimneys or stove pipes.
nLoosen the captive screw holding the faceplate to the mounting
plate.
oPull the lower part of the faceplate to remove it from the mount-
ing plate.
pLoosen the screw (captive) holding the wire cover and remove
the wire cover.
qPull wires through the hole in the mounting plate and secure the
mounting plate to the wall (or onto an electrical box for line volt-
age wiring) using the enclosed wall anchors and screws.
rWire the thermostat to the heating system (see section 1.2) and,
if necessary, connect the remote input (see section 1.3).
sOnce wiring is complete, re-install the wire cover.
tUse the switches located at the back of the faceplate to config-
ure your thermostat (see section 1.4) according to your applica-
tion.
uInstall the batteries (see section 1.5).
vMount the faceplate on the mounting plate and tighten the screw.
1.2 Thermostat Wiring
LOW VOLTAGE < 30 V: no polarity
LINE VOLTAGE 120 to 240 VAC
Must be installed onto a certified electrical box.
For a 2-wire connection: no polarity
For a 3-wire connection: observe the polarity
nInstallation
1.
NORTH AMERICA
EUROPE
Connection to a
circulator through
a 24 V relay
Connection to the
thermostat terminals
of a furnace
120/240 V
Relay
24 V transformer
Relay
Furnace
Connection to a
circulator (pump)
of a water heating
system
2 A maximum load
120/240 V
Power supply
Load
Provided wires
Direct wiring to
the circulator
Connection to the
thermostat terminals
of a furnace
240 V
Furnace
Relay
Wiring to a
power-operated
mixing control valve
240 V
TH140-28
Installation and User Guide
Electronic Programmable Thermostat
400-140-000-C (TH140-28) ENG.fm Page 1 Tuesday, January 15, 2008 1:46 PM
TH140-28 400-140-000-C 2008-01-15 2/4
1.3 Remote Input Wiring
The TH140 is equipped with a remote input which allows connection
of a telephone controller (optional Aube CT240), a home automation
system or any other remote control system. When a signal is
received through this input, the TH140 will automatically switch from
normal operating mode to Vacation mode, or vice versa when the sig-
nal is removed.
1.3.1 Connection to the CT240
Connect CT240 terminals A and C to TH140
terminals X and C. You must respect the
polarity.
For details on operating the telephone control-
ler, refer to the instruction manual.
1.3.2 Connection to a home automation system
Connect the TH140 to the home auto-
mation system as displayed in the wir-
ing diagram.
1.4 Configure the Thermostat
The switches are located on the back of the faceplate. Default set-
tings are highlighted.
1.4.1 Proportional Adaptive Mode (switch #5)
This mode analyzes previous cycles to define the the next duty cycle.
This control mode guarantees optimal temperature control based on
the system’s capacity. To extend the life of the system, a minimum
On/Off time of 10% of the cycle has been implemented. For example
with a 15-minute cycle, the system would not start or stop for less
than 1.5 minutes.
Ideal for:
Radiant or convection electrical heating system
Circulator control in a hot water system
Electrical hot-air furnace
Conventional gas or fuel hot-air furnace
Not recommended for:
Gas or fuel furnace or boiler with a wall chimney having a 30-sec-
ond or higher combustion gas purging cycle. To figure out the gas
purging cycle of your system, count the time between the heating
command sent by the thermostat and the moment when the
burner actually goes on.
Multi-zone systems, where several thermostats command a single
heating unit.
Note: In these last two cases, conventional mode with anticipation is
recommended.
Heating Cycle Selection (switches #1 and #2)
Select the cycle using switches #1 and #2. Short cycles help
eliminate temperature variations, thus increasing user comfort. Since
shorter cycles can lead to premature system wear, it is important to
select the temperature control cycles appropriate to your heating
system. In general, the bigger your heating unit is, the longer the
cycles should be.
1.4.2 Conventional mode with anticipation (switch #5)
This mode is compatible with all heating systems.
Programmable Span Selection (switches #1 and #2)
Select the span using switches #1 and #2. The default temperature
span is 0.5°C (0.9°F). For example, if the temperature setpoint is
20°C (68°F), the heating system will turn on at 19.5°C (67.1°F) and
turn off at 20.5°C (68.9°F).
Switch Description UP DOWN
1 & 2 Cycles (proportional) 15 min (see 1.4.1)
Span (conventional) 0.5°C (0.9°F) (see 1.4.2)
3 Clock display 12H 24H
4Temperature display 1
1. If you change from °C to °F (or vice versa), you will need to reprogram
your Comfort, Economy and Vacation settings.
°F °C
5 Temperature control mode Proportional
(see 1.4.1)
Conventional
(see 1.4.2)
6Pump protection 2
2. For hot water installations, it is recommended to enable this option to acti-
vate the pump for one minute every 24 hours to prevent pump seizure.
Deactivate Activate
Home automation system
Cycles EUROPE AMERICA Position
5 minutes Not recommended for
furnaces
Not recommended for
central units
10 minutes Gas or electric
wall furnace
Radiant or convection
electric heating
15 minutes
Fuel or gas floor
furnace, forced air
heating
Central heating
20 minutes Commercial unit
Span Hot Water Heating Forced Air Heating Position
0,3°C
(0,5°F)
Not recommended for
furnaces
Not recommended for
central units
0,4°C
(0,7°F)
Gas or electric
wall furnace
Radiant or convection
electric heating 1
1. 240 volt heating with relay (baseboard, convector, radiant ceiling, etc.)
0,5°C
(0,9°F)
Fuel or gas floor
furnace Central heating
0,6°C
(1,1°F) Commercial unit
400-140-000-C (TH140-28) ENG.fm Page 2 Tuesday, January 15, 2008 1:46 PM
TH140-28 400-140-000-C 2008-01-15 3/4
1.5 Install the Batteries
When you first install the batteries, the unit runs a
sequence of tests and a complete reset to zero. The
screen should display 0:00 MO and the ambient tem-
perature. The current setpoint is 20°C.
The ambient temperature could be higher if you are holding
the TH140 in your hands. It will return to normal about one
hour after installation.
1.5.1 Replacing the batteries
The TH140 will display an icon indicating that
the batteries must be replaced. This icon will be
displayed for 60 days; after this delay, the
TH140 will shut down the heating unit.
The time and programming are saved for
15 seconds when replacing the batteries.
Note: You may program the thermostat while holding it in your hands
or when it is mounted on the mounting plate.
2.1 Set the Time and Day
nSet the time, using the Hour and Minute buttons.
oSet the day, using the Day button.
2.2 Configure the Setpoints
2.2.1 Comfort and Economy
These setpoints are associated to the schedule’s programs and are
pre-programmed as follows:
2.2.2 Vacation
This pre-programmed setpoint is used when the Vacation mode is
activated.
2.2.3 To Modify a Setpoint
nSet the temperature using .
oPress and hold one of the setpoint
buttons ( or or ) until the
icon is displayed on the screen
(approx. 3 seconds).
2.3 View the Current Setpoint
To view the current setpoint, quickly press
once one of the arrow buttons .
The screen displays the setpoint; the arrow
indicates a setpoint.
The TH140 offers three operating modes:
3.1 Automatic
This mode executes the schedule. To activate:
Press Manual/Auto until is displayed. The program
setpoint icon is displayed.
3.1.1 Temporary Bypass
When in Automatic mode, you can temporarily bypass the
current program setpoint until the beginning of the next program. To
bypass:
Set the desired temperature OR quickly press or to
use a pre-defined setpoint.
3.2 Manual
This mode allows you to maintain a constant temperature.
To activate this mode:
Press Manual/Auto until is displayed.
Set temperature OR quickly press or to use
a pre-defined setpoint.
3.3 Vacation
Maintains a specific temperature when away for a pro-
longed absence (e.g. vacation).
From the TH140, quickly press to activate.
Can also be activated remotely (CT240, home automa-
tion system or any other system) if the remote input is
connected to one of these systems.
Note: When the Vacation mode is activated remotely, it can only be
deactivated remotely.
Note: For details on how to activate the Vacation mode using a tele-
phone, refer to the CT240 Instruction Manual.
The TH140 allows four setting changes for each day of the week.
There are no pre-set programs. Your heating system switches betw-
wen the Comfort setpoint and the Economy setpoint according to the
times you would have set.
For example, enter each day the time at which you wake up
(PROG 1), the time you leave for work (PROG 2), the time you return
home (PROG 3) and the time you go to bed (PROG 4):
Note: For temperature increases (PROG 1 and 3), allow at least
15 minutes per 1°C (2°F). For example, if you have lowered
the temperature by 3°C (6°F) while you sleep and you wake up
at 7 a.m., change the setting at 6:15 a.m.
oBasic Configuration
2.
Comfort 20°C (68°F) Programs 1 and 3
Economy 18°C (64°F) Programs 2 and 4
Vacation 10°C (50°F)
pSelect the Operating Mode
3.
qProgram Your Schedule
4.
Programs Associated Setpoint Time
PROG 1 (Comfort) Wake-up
PROG 2 (Economy) Leave
PROG 3 (Comfort) Return
PROG 4 (Economy) Sleep
400-140-000-C (TH140-28) ENG.fm Page 3 Tuesday, January 15, 2008 1:46 PM
TH140-28 400-140-000-C 2008-01-15 4/4
4.1 Set or Modify the Programs
After 60 seconds of inactivity, the thermostat will automatically exit
programming mode.
It is sometimes faster to program the same schedule for the entire
week and then modify the exception days.
nPress Program. The screen displays MO and PROG 1.
oPress Day to select the day (hold for 3 seconds to select all days
of the week).
pPress Hour and Minute to set the start time.
To clear an entry, press Clear, the time zone displays --:-- when
the program is inactive.
qPress Program to select the program number (2, 3 or 4).
rRepeat steps 3 and 4 for remaining programs.
sPress Manual/Auto to exit.
4.1.1 Programming Example
Comfort (programs 1 and 3):
Monday to Friday between 6:00 a.m. and 8:30 a.m. and
between 4:00 p.m. and 11:00 p.m.
Saturday and Sunday between 6:00 a.m. and 11:00 p.m.
Economy (programs 2 and 4):
Monday to Friday between 8:30 a.m. and 4:00 p.m. and
between 11:00 p.m. and 6:00 a.m.
Saturday and Sunday between 11:00 p.m. and 6:00 a.m.
To program this schedule:
nPress Program. The screen displays MO and PROG 1.
oPress and hold Day for 3 seconds to select all days of the week
(MOTUWETHFRSASU).
pSet the time (6:00) for the first program (PROG 1) using the
Hour and Minute buttons.
qPress Program to select PROG 2. Set the time (8:30) using the
Hour and Minute buttons.
rPress Program to select PROG 3. Set the time (4:00 p.m.) using
the Hour and Minute buttons.
sPress Program to select PROG 4. Set the time (11:00 p.m.)
using the Hour and Minute buttons.
tPress Manual/Auto to exit.
To erase programs 2 and 3 for Saturday and Sunday:
nPress Program to access programming mode.
oPress Program until PROG 2 is selected.
pPress Day to select SAturday (SA).
qPress Clear to erase the time (--:--).
rPress Day to select SUnday (SU).
sPress Clear to erase the time (--:--).
tRepeat steps 2 to 5 for PROG 3.
uPress Manual/Auto to exit.
Power supply: 2 AA or LR6 alkaline batteries 1.5 V
Max. resistive load: 5 A @ 240 VAC / 5 A @ 30 VDC
Max. inductive load: 2 A @ 240 VAC / 2 A @ 30 VDC (P.F. = 0.4)
Remote input: 12 VDC, ± 10%, 2.5 mA
Certifications: CE, c UL us
Control device: Electronic
Automatic action: Type 1 B
Number of programs: 4 programs / day, total of 28 programs
Storage temperature: -20°C to 50°C (-4°F to 122°F)
Operating temperature: 0°C to 50°C (32°F to 122°F), 95% R.H.
Temperature setting range: 5°C to 30°C (40°F to 85°F)
Temperature display resolution: 0.1 degree
Temperature reading accuracy: ± 0.5°C (± 0.9°F)
Software: Class A
Protection class: II
Protection degree: IP 40
The terminals are designed to handle a cross-section of wire measur-
ing up to 2.5 mm2 (14 AWG).
Aube warrants this product, excluding battery (if applicable), to be free from defects in the
workmanship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty period the
product is determined to be defective or malfunctions, Aube shall repair or replace it (at
Aube's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or
(ii) contact Aube. Aube will make the determination whether the product should be
returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Aube that the defect or malfunction was caused by damage which
occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms stated
above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS
OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and
states do not allow the exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some
provinces and states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from province or state to another.
For more information on our products, visit us at
www.aubetech.com
PROG MON TUE WED THU FRI SAT SUN
1 6:00 6:00 6:00 6:00 6:00 6:00 6:00
2 8:30 8:30 8:30 8:30 8:30 --:-- --:--
3PM 4:00 PM 4:00 PM 4:00 PM 4:00 PM 4:00 --:-- --:--
4PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00
rTechnical Specifications
5.
;Warranty
6.
Technical Assistance
7.
705 Montrichard
Saint-Jean-sur-Richelieu
Québec, Canada J2X 5K8
Tel. : (450) 358-4600
1-800-831-AUBE
Fax : (450) 358-4650
aube.service@honeywell.com
10 rue Ampère
95500 Gonesse
France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19
advaube@comintes.com
400-140-000-C (TH140-28) ENG.fm Page 4 Tuesday, January 15, 2008 1:46 PM

Navigation menu