Aube Technologies Ti040 Users Manual 400 040 001 Industrial Indoor/Outdoor Timer

TI040 to the manual ac2e7ae5-4a96-457e-8918-66d6e8b10bab

2015-02-06

: Aube-Technologies Aube-Technologies-Ti040-Users-Manual-500560 aube-technologies-ti040-users-manual-500560 aube-technologies pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadAube-Technologies Aube-Technologies-Ti040-Users-Manual- 400-040-001 TI040 Industrial Indoor/Outdoor Timer  Aube-technologies-ti040-users-manual
Open PDF In BrowserView PDF
400-040-001-A ENG.fm Page 1 Monday, January 15, 2007 8:36 AM

TI040
Installation and User Guide
Industrial Indoor / Outdoor Timer

n

1.

Applications

Load type

Maximum load

Examples

30 A

•
•
•

incandescent lights
halogen lights
block heater

Inductive
load

10 A

•
•
•
•

fluorescent lights
compact fluorescent lights (CFL)
sodium lamps
electronic ballasts

Motor

1.5 hp @ 120 VAC
2.0 hp @ 240 VAC

•
•

pool filter pumps
fans

Resistive
load

o

p

3.

Power-On
Mode display

On/Off display

• Briefly press the
button to turn the
load On or Off.
• Press the button for
3 seconds to switch
between Automatic
mode and Manual
mode.

2.

Installation

Program number

At power-on, 0:00 will flash. Otherwise, press reset using a paper
clip. If the display is blank, verify the power supply.

q

4.

Setting the Clock

NOTE: The switch displays the time in 24-hour format by default or
following a reset.

Line voltage
selector
switch

n

To change to 12-hour format (or vice versa), proceed as follows:
a) Press the MODE button to ensure the MAN or AUTO indicator is displayed.
b) Press the MIN and HOUR buttons simultaneously and briefly
(0:00 display = 24-hour, 12:00 display = 12-hour).

o
Single-pole switch
(for 3-way installation)

Power supply
(120/208/
240 VAC)

Motor

p
q
Lighting

n
o

Cut power at the circuit breaker to avoid electric shock.
Perform the connections as shown on the wiring diagram.

NOTE: For a 3-way installation, connect a standard single-pole
switch to the 3-way terminals of the timer as shown on the wiring
diagram.

p
q

Select the proper operating voltage.
Apply power at the circuit breaker.

Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.
Set the day by using the DAY button.
Press the MODE button to return to normal operation.

r

5.

Selecting the Operating Mode

The programmable switch has 2 operating modes: manual (MAN)
and automatic (AUTO). To switch mode, press the MODE button for 3
seconds.
Manual Mode
In Manual mode, the timer operates like a regular switch. Briefly
press the MODE button to activate or deactivate the load. (If you
have connected a remote switch to the timer for a 3-way installation,
the switch can also be used to activate or deactivate the load.) The
mode indicator (MAN) and the state (ON or OFF) are displayed.
Automatic Mode
In Automatic mode, the timer follows the programmed schedule (see
section 6). The mode indicator (AUTO), the state (ON or OFF) and
the current program number are displayed.
To temporarily override the programmed schedule, press the MODE
button or use the 3-way installation switch (if connected). The new

TI040

400-040-001-A

15/1/07

1/2

400-040-001-A ENG.fm Page 2 Monday, January 15, 2007 8:36 AM

state indicator will flash to show that this state is temporary. The
override remains in effect until you press the MODE button (or use
the remote switch) or until the beginning of the next program.

s

Programming

6.

You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).

o

p

q

r
s

Press the PGM button to display a program and its On or Off
time. For example, when you first press PGM, program number
1 (P1) and its On time (ON) will appear. - : - - will appear instead
of the time if the program is not set (inactive).
Press the DAY button to select the day to which you want to
apply the program.
NOTE: If you want to apply the same program to each day of the
week, press DAY until all the days are displayed. (This still
counts as 1 program, not 7.)
Press the HOUR and MIN buttons to set the ON time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that PM appears on the screen when an
afternoon time is displayed.
After you have programmed the ON time, press the PGM button
to display the OFF time (time when you want the lights to turn
off).
Repeat steps 3 through 5 to program the OFF time.
NOTE: If you have used only one program to set the ON time for
all 7 days, the OFF time of that program will automatically apply
to all 7 days.

t

To set another program, repeat steps 2 through 6. Programs that
are not set will remain inactive.

u

Press the MODE button to return to normal operation.

Clearing a Program
Press the PGM button until the desired program is selected. Hold the
PGM button for 3 seconds. - : - - appears when the program is
erased.

t

Technical Specifications

Supply: 120/208/240 VAC, 50 / 60 Hz
Maximum load: See section 1
3-way input: Requires a dry contact
Operating temperature range: -40 °C to 50 °C (-40 °F to 122 °F)
Enclosure type: 3R
Certifications: CSA & UL
Power outage: The programs are protected by a rechargeable
battery. The screen is blank during the power outage.

7.

;

8.

Warranty

AUBE warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, AUBE shall repair or
replace it (at AUBE's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
(ii) contact AUBE. AUBE will make the determination whether the
product should be returned, or whether a replacement product
can be sent to you.
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by AUBE that the defect or malfunction was caused by damage which occurred while the product
was in the possession of a consumer.
AUBE's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces, states or regions do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from one province, state or region to another.



9.

Customer Assistance

If you have any questions on the product installation or operation,
contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: aube.service@honeywell.com
For more information on our products, go to
www.aubetech.com

TI040

400-040-001-A

TROUBLESHOOTING

15/1/07

2/2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Assemble, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:07:22 11:01:37-05:00
Create Date                     : 2007:01:15 09:00:51-05:00
Metadata Date                   : 2009:07:22 11:01:37-05:00
Format                          : application/pdf
Title                           : 400-040-001 TI040 Industrial Indoor/Outdoor timer
Creator                         : Aube Technologies
Description                     : Installation and User Guide
Document ID                     : uuid:9e0e2b4d-243b-4f75-be03-a9ed06888b94
Instance ID                     : uuid:408a9662-503d-4c89-9afb-60aac3e82e24
Page Count                      : 2
Subject                         : Installation and User Guide
Author                          : Aube Technologies
EXIF Metadata provided by EXIF.tools

Navigation menu