Original instructions
DYNAMIC SERIES
Part D: ARX receiving unit
INDEX
Description ............................................................................................................. 2
1.1 Safety functions of the ARX receiving unit ........................................................ 3
Technical data ........................................................................................................ 3
Technical data sheet .............................................................................................. 3
Plates ...................................................................................................................... 4
Light signals ........................................................................................................... 4
5.1 POWER LED (green) ........................................................................................ 4
5.2 ALARM LED (red) ............................................................................................. 5
5.3 STATUS LED (blue) .......................................................................................... 5
5.4 SETUP LED (yellow) ......................................................................................... 5
Values of proportional outputs ............................................................................. 6
6.1 Calibrating maximum and minimum values of proportional outputs ................... 7
6.2 Calibrating values related to the rest position of proportional outputs (offset) .... 8
6.3 Inversion of movement direction of the joystick's axis ....................................... 8
6.4 Restoring factory settings ................................................................................. 9
Malfunction signalled by the receiving unit ....................................................... 10
AUTEC
LIARXE00-00
2
Description
Description
Vor Inbetriebnahme die Gebrauchsanleitung lesen.
Sicherheitsnormen beachten.
Die Speisespannung muss ausgeschaltet
werden, falls der Empfänger geöffnet wird.
Kein Hochdruckreiniger verwenden.
POWER SUPPLY...................................12-24V
300mA
........................................................max 8-30V
400mA
RADIO MODULE..............................................FSARTBEU2
FREQUENCY RANGE......................................863-870MHz
RF OUTPUT POWER.....................................<25mW ERP
PROTECTION DEGREE...............................................IP65
Avant de faire la mise en marche, lire le manuel de
l’utilisateur. Respecter le consignes de sécurité.
Couper l’alimentation avant d’ouvrir le boîtier.
Ne pas utiliser nettoyeurs à jet d'eau sous pression.
Antes de encenderlo leer el manual.
Atenerse a las normas de seguridad.
Desconectar la alimentación antes de abrir.
Nunca usar hidrolimpiadoras de alta presión.
PU8159-00
Before switching on please read the user manual.
Adhere to safety rules.
Disconnect power source before opening.
Do not use high pressure water cleaners.
TAXXXX-00 A0TARG01P0XXX
Prima dell'accensione leggere il manuale d’uso.
Attenersi alle norme di sicurezza.
Togliere l’alimentazione in caso di apertura.
Non utilizzare idropulitrici ad alta pressione.
TEACH
SERIAL N.
XXXXXX
MANIF. DATE XXXX
LEDs
plug
antenna
DTK connector (for memory board)
mounting holes
IDK (for address key)
TEACH pushbutton
fuse F1
connector for cable control
DIP switches
LIARXE00-00
AUTEC - Dynamic Series
Technical data
The receiving unit communicates with the machine thruough the output and the corresponding
wiring.
1.1
Safety functions of the ARX receiving unit
The SO1 and SO2 outputs may be either STOP (stop function) or SAFETY outputs (UMFS
function), according to the configuration of the receiving unit (see technical data sheet).
If thet are configured as STOP outputs the UMFS safety function is not available.
If they are configured as SAFETY outputs both the UMFS and stop safety functions are
available.
Technical data
Power supply ......................................................................................................... 8-30V
Antenna ............................................................................................................... dedicated
Rated current of the SO1 and SO2 outputs ...................................................... 2A (30V )
Rated current of digital outputs ......................................................................... 2A (30V )
Rated current of analogue outputs (PWM) ........................................................ 2A (30V )
Rated current of analogue outputs (voltage) ................................................ 10mA (28V )
Protection of outputs (fuse F1) ........................................................ 10A (32V , autofuse)
Housing material ........................................................................................... PA6 (20% fg)
Protection degree ........................................................................................ IP66 (NEMA 4)
Dimensions ................................................................. 202x123x83mm (7.95x4.84x3.23In)
Weight ............................................................................................................ 1.2kg (2.7Lb)
Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit configuration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be filled in, checked and signed by the installer, who is
responsible for a correct wiring.
A copy of the technical data sheet must always be kept together with this manual (always
keep a copy of this data sheet for administrative purposes).
The wiring of the receiving unit outputs must always reflect the wiring
indicated in the technical data sheet.
AUTEC - Dynamic Series
LIARXE00-00
4
Plates
Plates
The receiving unit has the following plates:
Plate
Position
Content
radio remote control
identification plate
On the cover of the
receiving unit
Radio remote control serial number
(S/N), bar code and manufacturing year.
technical data plate
On the cover of the
receiving unit
MODEL, TYPE and main receiving unit
technical data, marking and possible
radio remote control marks.
Light signals
The receiving unit ARX has four LEDs:
-- POWER is green
-- ALARM is red
-- STATUS is blue
-- SETUP is yellow
5.1
POWER LED (green)
The POWER LED indicates the status of the receiving unit and of the radio link.
The POWER LED...
…is off
The receiving unit is switched off.
...is on
The receiving unit is powered and there is no radio link.
… blinks
LIARXE00-00
Meaning
The receiving unit is powered and radio link has been
built.
AUTEC - Dynamic Series
Plates
5.2
ALARM LED (red)
The ALARM LED warns about anomalies in the receiving unit.
The ALARM LED...
…is off
The receiving unit works correctly.
... blinks once
Error on the STOP outputs.
... blinks twice
Error on the SAFETY outputs.
... blinks three times
... is on
5.3
Meaning
Error on the outputs corresponding to direction
commands.
Configuration erroron the SO1 and SO2 outputs.
STATUS LED (blue)
The STATUS LED warns about anomalies on the outputs or on the power supply and indicates
the reception of data from the transmitting unit.
The STATUS LED...
…is off
... blinks slowly
... blinks fast
... is on
5.4
Meaning
No radio link.
Over-voltage on power supply.
The receiving unit receives data from the transmitting unit.
Over-current in one of the PWM analogue outputs.
SETUP LED (yellow)
The SETUP LED shows the status of the data memory and of the address key, depending
on the receiving unit's working status.
The SETUP LED...
…is off
Meaning
The receiving unit works correctly.
... blinks once
Error on the address key.
... blinks twice
Error on the memory board.
AUTEC - Dynamic Series
LIARXE00-00
6
Values of proportional outputs
The SETUP LED...
... blinks quickly three times
The receiving unit is saving data set with the REMOTE
SETUP procedure (see chapter 6).
... blinks four times
Inversion of movement direction of the joystick's axis is
being performed within the REMOTE SETUP procedure
(see paragraph 6.3).
... blinks fast
Within the REMOTE SETUP procedure:
- two or more analogue commands are being activated
simultaneously or
- factory settings are being restored (see paragraph 6.4)
... is on
Meaning
Calibration of maximum and minimum values of
proportional outputs is being performed within the
REMOTE SETUP procedure (see paragraph 6.1).
Values of proportional outputs
Proportional outputs in the ARX receiving unit are factory set: values are given in the technical
data sheet.
The REMOTE SETUP procedure is used to modify:
-- maximum and minimum values of proportional outputs (see paragraph 6.1)
-- rest position values related to the proportional outputs (offset) (see paragraph 6.2)
-- movement direction of the joystick's axis (see paragraph 6.3)
The REMOTE SETUP procedure can only be performed by skilled and
properly trained personnel.
During the REMOTE SETUP procedure, pay particular attention to the machine
behaviour, as it moves as a response to acting on the actuators.
LIARXE00-00
AUTEC - Dynamic Series
Values of proportional outputs
The REMOTE SETUP procedure is used to modify one proportional output at a
time. The procedure will not be performed if the actuators corresponding to the
other proportional outputs are not in the rest position.
If necessary, it is possible to restore factory settings at any time (see paragraph 6.4).
6.1
Calibrating maximum and minimum values of proportional outputs
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until the SETUP
LED illuminates.
3. Set the desired values as follows:
-- To set the maximum value, move the joystick to the maximum range of the semi-axis
to be calibrated. Maintain the position and use the TEACH selector on the transmitting
unit to set the desired value.
-- To set the minimum value, move the joystick slightly out of the rest position of the
semi-axis to be calibrated. Maintain the position and use the TEACH selector on the
transmitting unit to set the desired value.
-- After calibrating one joystick, press the STOP pushbutton to save calibrations.
Calibrations are saved in the data memory on the DTK connector.
4. To set other values, unlock the STOP pushbutton, press the START pushbutton and
repeat actions described in the previous point.
5. To leave the procedure, press the TEACH pushbutton on the receiving unit and do not
release it until the SETUP LED switches off.
If the proportional outputs are activated by actuators that are not joysticks (i.e.
potentiometer, switch), calibrate maximum and minimum values according to the
above mentioned procedure.
If a speed selector is present on the transmitting unit, minimum and maximum
values have to be calibrated for each of the selector positions.
If inputs are used in the receiving unit to select different speeds, calibration must
be performed for any possible configuration of the inputs.
AUTEC - Dynamic Series
LIARXE00-00
8
Values of proportional outputs
6.2
Calibrating values related to the rest position of proportional outputs
(offset)
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until the SETUP
LED illuminates.
3. Enable and release the TEACH + command of the corresponding switch on the transmitting
unit and press and release the START pushbutton within one second.
4. Repeat actions described in the previous point until the SETUP LED on the receiving
unit starts blinking three times.
5. Set the desired values as follows:
-- Move the joystick out of the rest position of the axis to be calibrated. Maintain the
position and use the TEACH selector on the transmitting unit to set the desired value.
-- After calibrating one joystick, press the STOP pushbutton to save calibrations.
Calibrations are saved in the data memory on the DTK connector.
6. To set other values, unlock the STOP pushbutton, press the START pushbutton and
repeat actions described in the previous point.
7. To leave the procedure, press the TEACH pushbutton on the receiving unit and do not
release it until the SETUP LED switches off.
If the proportional outputs are activated by actuators that are not joysticks (i.e.
potentiometer, switch), calibrate values related to the rest position according to
the above mentioned procedure.
6.3
Inversion of movement direction of the joystick's axis
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until the SETUP
LED illuminates.
3. Enable and release the TEACH + command of the corresponding switch on the transmitting
unit and press and release the START pushbutton within one second.
4. Repeat actions described in the previous point until the SETUP LED on the receiving
unit starts blinking four times.
5. Set the desired values as follows:
-- Move the joystick out of the rest position of the axis to be calibrated. Maintain this
position and activate once the TEACH + command related to the corresponding switch
on the transmitting unit.
-- After calibrating one joystick, press the STOP pushbutton to save calibrations. All
calibrations are saved in the memory board.
6. To invert other directions, unlock the STOP pushbutton, press the START pushbutton
and repeat actions described in the previous point.
7. To leave the procedure, press the TEACH pushbutton on the receiving unit and do not
release it until the SETUP LED switches off.
LIARXE00-00
AUTEC - Dynamic Series
Values of proportional outputs
6.4
Restoring factory settings
This procedure is used to restore factory settings for the proportional outputs.
1. Ensure that the transmitting unit is switched off.
2. Power on the receiving unit.
3. Press the TEACH pushbutton in the receiving unit and do not release it until the SETUP
LED illuminates.
4. Press the TEACH pushbutton three times and do not release it at last pressure; the SETUP
LED blinks fast: this indicates that factory settings are being restored.
5. Release the TEACH pushbutton when the SETUP LED is steadily illuminated again. If
the TEACH pushbutton is released before the SETUP LED is steadily illuminated, factory
settings of proportional outputs will not be restored.
6. To leave the procedure, press the TEACH pushbutton on the receiving unit and do not
release it until the SETUP LED switches off.
AUTEC - Dynamic Series
LIARXE00-00
10
Malfunction signalled by the receiving unit
Malfunction signalled by the receiving unit
Use the light signals on the receiving unit to identify the radio remote control malfunction.
If the problem persists after the suggested solution has been carried out, contact the support
service of the machine manufacturer.
Signals
Possible reason
Solutions
The POWER LED is off.
The receiving unit is
switched off.
Disconnect the power supply and restore
it after 5 minutes to make sure that a
restorable thermal fuse integrated in the
receiving unit has not been activated.
Correctly plug in the connecting plug
and power on the receiving unit.
The POWER LED is on.
No radio link.
Bring the transmitting unit close to the
receiving unit.
The ALARM LED blinks
once.
Error on the STOP
outputs.
Make sure that fuse F1 is intact.
Correctly plug in the connecting plug.
Make sure that the STOP outputs are
wired correctly.
The ALARM LED blinks
twice.
Error on the SAFETY
outputs.
Make sure that fuse F1 is intact.
Correctly plug in the connecting plug.
Make sure that the SAFETY outputs are
wired correctly.
The ALARM LED blinks
three times.
Error on the outputs
corresponding to direction
commands.
Contact the support service of the
machine manufacturer.
Make sure that the outputs of direction
commands are wired correctly.
The ALARM LED is on.
Configuration erroron the
SO1 and SO2 outputs.
Make sure that the DIP switches are set
as on the technical data sheet.
If this signal persists, contact the support
service of the machine manufacturer.
LIARXE00-00
AUTEC - Dynamic Series
Malfunction signalled by the receiving unit
Signals
Possible reason
11
Solutions
The STATUS LED blinks
slowly.
Over-voltage on power
supply.
Make sure that the receiving unit power
supply is within the voltage limits
provided in the technical data.
The STATUS LED blinks
fast and irregularly.
The receiving unit loses
some data sent by the
transmitting unit.
Bring the transmitting unit close to the
receiving unit.
If this signal persists, contact the support
service of the machine manufacturer.
The STATUS LED is on.
Over-current in one of the
PWM analogue outputs.
Contact the support service of the
machine manufacturer.
The SETUP LED blinks
once.
Error on the address key.
Contact the support service of the
machine manufacturer.
The SETUP LED blinks
twice.
Error on the memory
board.
Contact the support service of the
machine manufacturer.
The SETUP LED blinks
quickly.
Two or more analogue
commands are being
activated simultaneously
within the REMOTE
SETUP procedure.
Check actuators on the transmitting
unit and activate one single analogue
command.
AUTEC - Dynamic Series
LIARXE00-00


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2013:10:03 09:02:45+02:00
Metadata Date                   : 2013:10:03 09:02:49+02:00
Modify Date                     : 2013:10:03 09:02:49+02:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:d867e173-4e5b-4904-9621-64c41bd3b0f1
Original Document ID            : xmp.did:3E97F9BFF011E111AF74C00038EEA0BF
Document ID                     : xmp.id:728453C6F92BE31197F4EBBE6D886F23
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:718453C6F92BE31197F4EBBE6D886F23
Derived From Document ID        : xmp.did:718453C6F92BE31197F4EBBE6D886F23
Derived From Original Document ID: xmp.did:3E97F9BFF011E111AF74C00038EEA0BF
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:10:03 09:02:45+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 12
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OQA-ARXNG022

Navigation menu