BTR manual
NTP#: 411-1333-920
Draft 01.01 June 2000
BTR 28-07 GHz MMIC
Quick Reference Guide
Product Overview
The BTR 28-07 GHz MMIC (NTVG14CA) outdoor transceiver is a state-of-the-
art broadband microwave transceiver designed to operate at various frequency
bands downstream. It is a combined broadband transmitter and receiver deployed
in Nortel Networks Reunion point-to-multipoint system. It is compatible with
Reunion’s Release 1.2 and 1.3 equipment.
Figure 1: BTR 28-07M Block Diagram
Rx IF Output
Tx IF Input
Transceiver
Lightening
Radio
Protector
Lightening
Protector
Rx RF Input
(Test Point ‘B’)
(Test Point ‘A’)
Tx RF Output
Test Por t
Rx IF Output
Test Por t
Lightening
Protector
BTR 28-07M Transceiver
Tx IF/DC Input
411-1333-920 Draft 01.01 June 2000
2
BTR 28-07 MMIC Specification
Table 1: BTR 28-07M Technical Specifications
TX IF Input RF Output
Frequency Range 28-07M 500-650 MHz 29.10-29.25 GHz
Output Level (P1 dB) ≥27 dBm, -40° to +55° C
Output Level (IP3) > +35 dBm
Input Impedance 50 Ohms
Input/Output Connector N-Type Female WR-28
Input/Output VSWR 1.925:1, maximum 2.32:1, max (or 8 dB)
Gain (not including antenna) 32±.6 dB, minimum
Gain Variation ±5.0 dB over all conditions
Gain Flatness ±1.9 dB, maximum
LO leakage -30 dBm
Frequency Stability <±4 ppm, (-40° to +55° C) and aging
Tx Noise Power -115 dBm/Hz, maximum
Tx IF Test Port Coupling -16± 1 dB
Antenna BTR
Frequency 27.5-31.3 GHz
Frequency Band 2731
Bore-sight Gain (Azimuth) 15.75±1.25 dBi, 90° Horn
18.90±1.25 dBi, 45°
23.8±1.3 dBi, 15°
Wave-guide Interface WR-28 size non-standard hole pattern
Size (Length x Height x Width) 10" x 9" x 2" (90°)
Polarity single pole (H/H & V/V polarization)
Sectorized Angle Available 15°, 45°, and 90°
BTR 28-07 GHz MMIC Quick Reference Guide
3
RX RF Input IF Output
Frequency Range 28-07M 28.20-28.35 GHz 250-400 MHz
Input/Output Connector WR-28 non-standard hole
pattern N-Type Female
Input IP3 level -10 dBm, minimum
Output Impedance 50 Ohms
Input/Output VSWR 2.32:1, max (or 8.0 dB) 1.925:1 (10 dB)
Gain (not including antenna) 28.0 ± 0.6 dB
Gain Variation ±5.0 dB over all conditions
Gain Flatness ±1.9 dB over bandwidth
Gain Stability ±2.5 dB over temp.
Frequency Stability <±4 ppm, over all conditions
LO Leakage -35 dBm, maximum
Noise Figure ≤ 7.2 dB, maximum
Rx IF Test Port Coupling -14 ±1 dB
Power Requirements BTR
Input Voltage -48 VDC
Input Current <2 Amp
Input Power 50 Watts, maximum
Environmental BTR
Humidity 100% condensing
Altitude 10,000 feet
Operating Temperature -40° to +55°C
Storage Temperature Range -45° to +70°C
Mechanical BTR
Size (Length x Height x Width) 19.2" x 10.3" x 6.7" (49 x 26 x 17 cm)
Weight without brackets 35 lbs. (16KG)
Information is subject to change without notice.
Nortel reserves the right to make changes in
design or components as progress in engineering
and manufacturing may warrant.
© 2000 Northern Telecom Ltd.
Converted Frequency Formula
Use the following formula to calculate the converted frequency:
TX: ƒRF OUT (GHz) = 28.60 (GHz) + ƒIF INPUT (MHz)
RX: ƒIF OUTPUT (MHz) = 28.60 (GHz) - ƒRF INPUT (GHz)
Note: The antenna has an option of a hydrophobic coating that can help to
reduce ice build-up effect.
Note: Vent holes are covered with a GoretexTM patch.
Note: The transceiver mounts to a vertical pole of 2.5” to 4.5” outside diame-
ter. It has a range of motion of 90° over and -60° under horizon. The bases of
the antenna mount can rotate ±180°.
Note: The module connector is N-Type female. The receive IF input/output
cables present a male N-Type connector. The Tx IF and the Rx IF test ports
are SMA-Type female. The Telemetry port: 6 pin female military-style con-
nector.
Technical Assistance Contact Information
In case additional technical assistance is required, or the transceiver unit is
damaged upon receipt, contact Nortel Networks.
Nortel Networks Broadband Wireless Access (BWA) provides 24-hour customer
service and technical support to ensure your service operation is trouble-free.
If you have questions or need technical support, contact Nortel Networks
Broadband Wireless Access at the following telephone numbers:
• In the USA and Canada, call 972-BWA-ETAS/972-292-3827