Avaya Canada BTS18000MCPA GSM 18000 MCPA BTS User Manual v160pdg

Avaya Canada Corporation GSM 18000 MCPA BTS v160pdg

Exhibit 8 User Manual

Download: Avaya Canada BTS18000MCPA GSM 18000 MCPA BTS User Manual v160pdg
Mirror Download [FCC.gov]Avaya Canada BTS18000MCPA GSM 18000 MCPA BTS User Manual v160pdg
Document ID489907
Application IDqhPYjkKQ7BYut8gPBXT8AA==
Document DescriptionExhibit 8 User Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize49.63kB (620379 bits)
Date Submitted2004-11-19 00:00:00
Date Available2004-11-18 00:00:00
Creation Date2004-10-04 18:06:05
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2004-11-09 11:56:23
Document Titlev160pdg
Document CreatorPScript5.dll Version 5.2
Document Author: frederic.blin

< 142 > : BTS18000 Reference Manual
Wireless Service Provider Solutions
BTS18000 Reference Manual
Document number: PE/DCL/DD/0160
411--9001--160
Document status: Preliminary
Document issue:
15.01/EN
Product release:
GSM/BSS V15.0.1
Date:
October 2004
Welcome screen
Table of contents
List of figures
List of tables
Copyright © 2002--2004 Nortel Networks, All Rights Reserved
Originated in France
NORTEL NETWORKS CONFIDENTIAL:
The information contained in this document is the property of Nortel Networks. Except as specifically authorized in
writing by Nortel Networks, the holder of this document shall keep the information contained herein confidential and
shall protect same in whole or in part from disclosure and dissemination to third parties and use for evaluation,
operation and maintenance purposes only.
You may not reproduce, represent, or download through any means, the information contained herein in any way or in
any form without prior written consent of Nortel Networks.
The following are trademarks of Nortel Networks: *NORTEL NETWORKS, the NORTEL NETWORKS corporate logo,
the NORTEL Globemark, UNIFIED NETWORKS, S8000, S12000, BTS18000. GSM is a trademark of France Telecom.
Windows is a U.S. registered trademark of Microsoft Corp.
All other brand and product names are trademarks or registered trademarks of their respective holders.
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
Publication History
iii
PUBLICATION HISTORY
System release: GSM/BSS V15.0.1
September 2004
Issue 15.01/EN Preliminary
Creation for feature 25808 - BTS18000 introduction ready.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
iv
Table of contents
User’s help screen
Welcome screen
Nortel Networks Confidential
About this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0-- 1
Applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--1
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--1
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--1
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--1
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--2
Vocabulary conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--2
Regulatory information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0--3
BTS18000 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-- 1
1.1
Key market trends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--1
1.1.1
Operating expenses savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--1
1.1.2
Advent of new technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--1
1.1.3
Investment protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--2
1.1.4
Network coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--2
Nortel Networks BTS portfolio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--3
1.2.1
Nortel Networks BTS18000 solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--3
1.2.2
BTS18000 positioning in Nortel Networks BTS portfolio . . . . . . . . . . . . .
1--4
BTS18000 offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--6
1.3.1
BTS18000 versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--6
1.3.2
BTS18000 possible uses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--6
BTS18000 functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-- 1
2.1
GSM--UMTS dual technology proposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2--1
2.2
GSM features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2--1
2.3
GSM functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2--3
BTS18000 hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-- 1
3.1
Description of the cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--1
3.1.1
BTS18000 outdoor cabinet layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--1
3.1.2
BTS18000 indoor cabinet layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--2
3.1.3
Power supply (outdoor cabinet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--4
3.1.4
Cooling system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--4
3.1.5
Physical characteristics and environmental requirements . . . . . . . . . . .
3--5
Description of the modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--7
1.2
1.3
3.2
3.2.1
PE/DCL/DD/0160
411--9001--160
Interface Back Plane (IBP), Digital Back Plane (DBP) and Radio InterCOnnect board
(RICO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--7
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
Table of contents
3.2.2
Radio Module (RM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--7
3.2.3
High Power Radio Module (HPRM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--11
3.2.4
Interface Control Module (ICM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--11
3.2.5
Interface Module (IFM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--19
3.2.6
Spare Module (SPM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--19
3.2.7
Alarms and Bridge Module (ABM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--19
3.2.8
Dual Duplexer Module (DDM) and Transmit Filter (TXF) . . . . . . . . . . . .
3--23
MCPA BTS18000 configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-- 1
8.1
MCPA BTS18000 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--1
8.2
MCPA BTS18000 hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--1
8.2.1
8--1
Description of the MCPA BTS18000 outdoor cabinet . . . . . . . . . . . . . . .
Copyright E 2002--2004 Nortel Networks
Copyright BTS18000
E 2002--2004
Nortel Networks
Reference
Manual
Front page of manual
User’s help screen
Nortel Networks Confidential
8.2.2
8.3
Welcome screen
Table of contents
vi
Description of the MCPA BTS18000 specific modules . . . . . . . . . . . . . .
8--3
MCPA cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--6
8.3.1
MCPA rack overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--6
8.3.2
DLNA module overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--7
8.3.3
DLNA RF features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--8
8.3.4
VSWR meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--8
8.3.5
MCPA cabinet alarm monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8--9
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
viii
List of figures
User’s help screen
Welcome screen
Nortel Networks Confidential
Figure 1--1
BTS18000 positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1--4
Figure 3--1
BTS18000 outdoor equipped cabinet with door opened (front view) . . . . . . .
3--2
Figure 3--2
BTS18000 indoor equipped cabinet with door opened (front view) . . . . . . . . .
3--3
Figure 3--3
RM front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--8
Figure 3--4
BTS18000 corporate LEDs for RM, ICM and ABM . . . . . . . . . . . . . . . . . . . . . .
3--9
Figure 3--5
ICM front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--12
Figure 3--6
ICM Abis switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--15
Figure 3--7
ICM SW10 switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--17
Figure 3--8
ICM SW11 switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--18
Figure 3--9
ABM front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--21
Figure 3--10
DDM front panel (with H2 coupling option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--23
Figure 3--11
DDM LEDs and switches details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--24
Figure 3--12
TXF front panel (with H2 coupling option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3--26
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
List of figures
ix
Figure 8-- 1
MCPA BTS18000 outdoor equipped cabinet with door opened (front view) .
8-- 2
Figure 8-- 2
MRM front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-- 4
Figure 8-- 3
BTS18000 corporate LEDs for MRM, ICM and ABM . . . . . . . . . . . . . . . . . . . .
8-- 4
Figure 8-- 4
MCPA BTS18000 / MCPA cabinet digital links overview (configuration with three MCPA
racks) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-- 10
Figure 8-- 5
MCPA BTS18000 / MCPA cabinet digital links overview (configuration with six MCPA racks)
8-- 11
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
About this document
0--1
ABOUT THIS DOCUMENT
This document describes the new BTS18000 Base Transceiver Station (BTS),
which is a component of the Base Station Subsystem (BSS).
Applicability
This document applies to the V15.0.1 BSS system release.
Audience
This document is intended for operation and maintenance personnel, and for any
user who needs information relating to the BTS18000.
Prerequisites
It is recommended that the readers also become familiar with the following
documents:
< 000 > : BSS Product Documentation Overview
< 001 > : BSS Overview
< 007 > : BSS Operating Principles
< 039 > : BSS Maintenance Principles
< 124 > : BSS Parameter Dictionary
< 125 > : Observation Counter Dictionary
< 128 > : OMC--R User Manual -- Volume 1 of 3: Object and Fault menus
< 129 > : OMC--R User Manual - Volume 2 of 3: Configuration, Performance, and
Maintenance menus
< 130 > : OMC--R User Manual - Volume 3 of 3: Security, Administration,
SMS--CB, and Help menus
< 138 > : GSM BSS Engineering Rules
< 161 > : Fault Number Description: BTS18000
< 162 > : BTS18000 Maintenance Manual
Related Documents
The NTPs listed in the above paragraph are quoted in the document.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
0--2
User’s help screen
About this document
Welcome screen
Nortel Networks Confidential
How this document is organized
Chapter 1 presents the new BTS18000 product and situates it in the Nortel Networks
BTS portfolio.
Chapter 2 describes the BTS18000 functionality.
Chapter 3 describes:
the layout and content of the BTS18000 cabinets.
the functions of the BTS18000 boards and modules, as well as their front panels.
Chapter 4 describes the BTS18000 software.
Chapter 5 examines:
the BTS18000 functional architecture,
the BTS18000 hardware architecture.
Chapter 6 describes the GSM--UMTS dual mode configurations.
Chapter 7 describes the MCPA BTS18000 configurations.
Chapter 8 indicates that the dimensioning rules are now contained in NTP < 138 >
GSM BSS Engineering Rules.
Vocabulary conventions
The glossary is included in the NTP < 000 >.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
About this document
0--3
Regulatory information
This part which provides the regulatory information concerning the BTS is split into
the following items:
European regulatory requirement compliance,
North American regulatory requirement compliance,
Compliances for other regions/countries,
Operation conditions,
Cable specifications,
Product labeling.
European regulatory requirement compliance
As a radio product, the Nortel Networks BTS18000 falls under the requirement of
the RTTE (Radio and Telecom Terminal Equipment) European directive
1999/5/EEC. The RTTE directive covers essential requirements in the field of:
protection of the Health and Safety of the user and any other person, including the
objectives with respect to safety requirements contained in the Low Voltage
directive (73/23/EEC).
the protection requirements with respect to EMC contained in Directive
89/336/EEC.
The equipment generates, uses, and can radiate radio frequency energy. If not
installed and used in accordance with the instruction manual, the equipment may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference.
The EMC requirements have been selected to ensure an adequate level of
compatibility for apparatus at residential, commercial, and light industrial
environments. The levels however, do not cover extreme cases which may occur
in any location but with a low probability of occurrence. In particular, it may not
cover those cases where a potential source of interference which is producing
individually repeated transient phenomena, or continuous phenomena, is
permanently present, for example a radar or broadcast site in the near vicinity. In
such a case it may be necessary to either limit the source of interference, or use
special protection applied, to the interfered part, or both.
Note: For operation or maintenance inside Nortel Networks systems, the
antistatic wrist shall always be used to maintain the integrity of the
product.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
0--4
User’s help screen
About this document
Welcome screen
Nortel Networks Confidential
effective use of the Radio spectrum allocated to terrestrial/space radio
communication and orbital resources so as to avoid harmful interference. The
routes and standards used to demonstrate compliance with there essential
requirements are outlined in the following paragraphs.
- BTS EMC
Compliance with the essential requirements of EMC has been demonstrated using
EN301489--1 & - 23 standard.
- BTS radio compliance
Compliance with the essential requirements of effective use of the radio spectrum
has been demonstrated using EN301908--1 & - 3 standard.
-- BTS safety
Compliance with the essential requirements of Safety has been demonstrated using
EN 60950 Standard.
-- BTS health protection
Compliance with the essential requirement of health requirement has been
demonstrated using EN50385.
North American regulatory requirements compliance
The Nortel Networks BTS18000 has been qualified according to North American
market requirements for the Outdoor and MCPA versions.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
reorient or relocate the receiving antenna.
increase the separation between the equipment and receiver.
connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
consult the dealer or an experienced radio/TV technician for help.
-- BTS safety
Nortel Networks BTS18000 complies with UL60950 and CAN/CSA C22.2 No.
60950--00 Safety Standards. The CSA mark is applied on the BTS and demonstrates
compliance with both US and Canadian Standards.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
About this document
0--5
-- BTS EMC and radio compliance
Nortel Networks BTS18000 complies with 47CFR Part 15 class B and 47 CFR Part
24 for EMC and radio emission limits according to US regulatory requirements as
indicated on the regulatory label.
- BTS interconnection compliance
The Nortel Networks BTS18000 complies with 47 CFR Part 68 of the FCC rules
and the requirements adopted by the ACTA.
On the top right of this equipment is a label that contains, among other information,
a product identifier in the following format: US : AB6XDNANBTS18000
If requested, the following information must be provided to the telephone company:
FCC Registered Number: AB6.
Facility Interface Code (FIC): 04DU9.BN, 04DU9.DN, 04DU9.1KN, and
04DU9.1SN.
Service Order Code (SOC): 6.0F.
A FCC part 68 and ACTA compliant cable is provided with the BTS equipment,
with no connector at network interface side. The BTS equipment operates with a
1.544 Mbps digital channel. See Installation Instructions for details.
If the BTS18000 equipment causes harm to the phone network, the telephone
company will notify you in advance that temporary discontinuance of service may
be required. But if advance notice is not practical, the telephone company will notify
the customer as soon as possible. Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.
The telephone company may make changes to its facilities, equipment, operations
or procedures that could affect the operation of the equipment. If this happens the
telephone company will provide advance notice so you can make the necessary
modifications to maintain uninterrupted services.
If trouble is experienced with BTS18000 equipment, for repair or warranty
information, please contact:
Toy--Brent Lorance Nortel Networks
2370D Performance Dr.
Richardson, TX 75082
Phone: 972--685--2270
Fax: 972--684--7601
If the equipment is causing harm to the telephone network, the telephone company
may request that you disconnect the equipment until the problem is resolved.
All repairs should be handled by authorized Nortel Networks Service Personnel.
-- BTS18000 data equipment
The following table shows which jacks are associated with which modes of
operation.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
0--6
User’s help screen
About this document
Welcome screen
Nortel Networks Confidential
Operation mode
USOC Jack
Programmable & Test
RJ45S
- BTS18000 systems
Facility Interface Codes (FIC), Services Order Codes (SOC), USOC Jack Codes,
and Ringer Equivalence Number (REN) are shown in the table below for each port
where applicable.
Port
FIC
SOC
USOC Jack
REN
ICM T1 board
04DU9.BN
6.0F
N/A
N/A
ICM T1 board
04DU9.DN
6.0F
N/A
N/A
ICM T1 board
04DU9.1KN
6.0F
N/A
N/A
ICM T1 board
04DU9.1SN
6.0F
N/A
N/A
- BTS18000 RF health protection
Compliance with the North American requirements is demonstrated through
calculation according to FCC OET bulletin 65.
Compliances for other regions/countries
For countries outside Europe and the Americas, the requirements of European
countries usually apply.
It is not possible to list all the applicable approvals/compliances as they will be
dependent on the markets and products considered.
Note: Please contact your local Nortel Networks representative for more
information.
Operational conditions
The aforementioned standards compliance of the products are based on the
following operating conditions (called normal operation):
doors shall be closed and (or) covers shall be in place.
external cables shall be of the same type as specified by Nortel Networks.
no modification of any mechanical or electrical characteristics of the product
shall be made.
Any change or modification made to the product without written approval from
Nortel Networks releases Nortel Networks from subsequent responsibility
regarding the standards compliance.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
About this document
0--7
Cable specifications
The compliance to the aforementioned standards has been verified using cables as
specified by Nortel Networks. The continuing compliance of the product relies
upon use of the correct cabling scheme as well as use of identical type cables as
specified by Nortel Networks. Refer to the installation guides for details on cable
specifications.
Product labeling
The label may be located inside or outside the product, provided that the operation
and/or maintenance personnel have the information when working on the product.
- BTS labeling for American Countries
To indicate compliance with the CSA and UL Safety requirements, the Nortel
Networks BTS18000 bears the following mark in a conspicuous location.
On the regulatory label, compliance to 47 CFR Part 15, 24 and 68 is stated along
with:
FCC ID, FCC Registration Number.
Manufacturers name.
Equipment designation.
Nominal voltage operating range and maximum rated current.
-- BTS labeling for European Countries
To indicate compliance with the European RTTE Directive, the Nortel Networks
BTS18000 bears the following information in a conspicuous location:
Manufacturers name.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
0--8
User’s help screen
About this document
Welcome screen
Nortel Networks Confidential
Equipment designation.
Nominal voltage operating range and maximum rated current.
- Labeling for other regions / countries
Labeling for other regions and countries is performed as appropriate and required
by the local regulatory framework.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 overview
1--1
BTS18000 OVERVIEW
1.1
Key market trends
1.1.1
Operating expenses savings
Most of the operators in Europe and Asia are going to install UMTS equipment on
their networks, including UMTS radio cabinets. In most of the cases, these radio
equipments will be co--located with existing GSM sites.
Moreover, as GSM capacity increases in urban areas (voice and data traffic),
operators will need to install new radio transmitters and will be forced to limit the
number of additional radio cabinets required to carry the increasing traffic, in order
to contain the ”floor investments” at an acceptable level.
This results in a need for a Base Transceiver Station (BTS) solution with a high
number of transceivers per square meter, thus a cabinet which can house more TRXs
in the same footprint than S8000 and S12000 cabinets. This results as well in the
need for reduced power consumption, operational effectiveness, antenna tower
loading.
1.1.2
Advent of new technologies
The existing GSM European operators are almost all planning the deployment of
a 3G networks based on UMTS technology. Some of them have even started in 2001
but the massive deployment is just about to start.
In Asia, the scenario is almost the same and the Asian operators are also preparing
for 3G (CDMA 2000 or UMTS).
In the Americas, the path to 3G for GSM operators is likely to stop off at
GPRS/EDGE in a first stage with limited infrastructure investment before investing
massively in 3G technology.
The challenge for these operators is to increase the capacity and complete the
coverage of their GSM network while they are starting their investments in 3G
infrastructure. This results into two major difficulties for the operators:
Radio sites congestion.
Most of the urban sites are highly constrained by BTS footprint and will hardly
accommodate for both 3G and increased capacity GSM/GPRS base stations.
Therefore, dense and compact GSM and UMTS product solutions are required to
answer to this constraint.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
1--2
User’s help screen
BTS18000 overview
Welcome screen
Nortel Networks Confidential
Financing and cash flow.
Investing in a new technology (3G), while break in GSM has not been reached,
will require very cost--effective product solutions. GSM radio sites will be
reused. Some solutions, as dual mode UMTS/GSM base stations and/or
infrastructure sharing between 3G operators, will allow cost--effectively
launching UMTS services, before smoothly migrating the subscriber base from
GSM to UMTS.
This results in a need for a BTS solution supporting both GSM and UMTS.
1.1.3
Investment protection
Most of the GSM operators are facing the challenges to increase the capacity and
coverage of their existing networks as traffic is growing, and in the same time start
to invest in new UMTS network elements and buy expensive licenses. As a
consequence, the protection of the operators’ existing investments while they invest
in new network components is becoming more and more important to preserve their
business profitability.
This results in a need for a BTS solution which should offer the maximum of
compatibility with the existing S8000 and S12000 BTSs installed on the field (e.g.
possibility to expand existing sites).
1.1.4
Network coverage
GSM coverage is not everywhere today and the GSM operators will complete the
coverage of their network in the coming years, mainly in not very dense and rural
areas.
This results in the need for a very cost--effective, low capacity solution, offering
high coverage capabilities in order to limit the investment and balance the business
case of the operator for the low revenue generating areas.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
1.2
Welcome screen
BTS18000 overview
1--3
Nortel Networks BTS portfolio
Combined with Nortel Networks’ experience gained through manufacturing and
delivering more than 540,000 DRX and 100,000 BTS to more than 54 countries and
100 operators throughout the world, the DRX--based family of BTS products
provides the operator with the key ingredients required to minimize both:
the initial and ongoing infrastructure investment,
the ongoing operating expenses.
The Nortel Networks family of BTS products offers the flexibility of high
performance and dense packaging needed to provide the operator with optimum
network solutions.
This BTS portfolio benefits from Nortel Networks’ vast experience in spectrum
management and network engineering.
1.2.1
Nortel Networks BTS18000 solution
The new BTS18000 is the Nortel Networks solution for all needs previously
described in section 1.1.
Nortel Networks new dual technology BTS18000:
leverages the latest capabilities that our UMTS and GSM/GPRS/EDGE
portfolios have to offer,
provides a flexible deployment platform for the rollout of UMTS services to
meet customer demand.
All this provides operators with a mean to control timing and costs for new UMTS
deployments.
The BTS18000’s flexibility also allows operating in a GSM--only mode that offers,
in a single cabinet, omni--directional O16 or tri--sectorial S666 capacities and is
scalable to a three cabinet site supporting a tri--sectorial S16.16.16 capacity.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
1--4
User’s help screen
BTS18000 overview
1.2.2
Welcome screen
Nortel Networks Confidential
BTS18000 positioning in Nortel Networks BTS portfolio
Although a particular attention is paid on the high capacity configurations, the
BTS18000 is intended to cover almost all environments, from small towns (S111
type of configurations) up to indoor coverage (S16.16.16 and MCPA
configurations).
Small Towns
Highways
Rural
Suburban
Urban
Dense Urban
Indoor
e-Cell
S8000 (S111- S888)
S12000 (S111-S12
12 12)
–
BTS 18000 (S111-S18 18 18)
Figure 1--1
BTS18000 positioning
In addition, the BTS18000 provides 3G evolution and GSM/EDGE Radio Access
Network (GERAN) readiness to Nortel Networks GSM macro base station
portfolio.
The Nortel Networks BTS portfolio includes the products listed below.
1.2.2.1
BTS18000
This new family of BTS is based on a new highly integrated Radio Module (RM)
that provides the equivalent of three GSM/GPRS/EDGE transceiver channels
including power amplifier function. This represents further integration of the
successful single module DRX approach for the receiver, transmitter and frame
processor, used in Nortel Networks legacy S8000 and S12000 BTSs.
The BTS18000 is an ideal site solution for operators:
that have well established GSM networks evolving to EDGE, with a need for
high density BTS in urban deployments,
that are planning new hybrid GSM/UMTS networks enabling more advanced
data services traffic.
These hybrid networks offer the ultimate balance of GSM and UMTS without
any compromises. The inherent flexibility of the new BTS is the catalyst to
accelerate today’s investment decision needed to secure the operator’s success
today and tomorrow.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 overview
1--5
The BTS18000, which represents unprecedented capacity and flexibility, can
provide up to 54 TRX, with 18 TRX per sector, using only three cabinets.
1.2.2.2
S8000 BTS
The S8000 is a high performance BTS designed for macro--cellular voice and data
applications, that has a high modularity and expansion capability providing site
configurations ranging from 1 TRX to 8 TRX per sector in a tri--sectorial site, or
up to 16 TRX in an omni--directional configuration.
Because of its superior RF performance (high receiver sensitivity, interference
cancellation) and unique frequency re--use features, the S8000 BTS is an excellent
product that delivers wide coverage and optimizes spectrum efficiency. The S8000
BTS indoor version is designed for protected sites, while the outdoor version is a
fully integrated BTS site with AC power supply and extended temperature range.
1.2.2.3
S12000 BTS
The S12000 BTS is a twelve--transceivers, high--capacity solution designed to meet
the increasing traffic demand on macro cellular voice and future data applications.
The S12000 BTS can provide up to 36 TRX at a single site with 12 TRX per sector
using only three cabinets.
The S12000 BTS inherits the superior RF performances, unique features and main
modules of the S8000 BTS market--proven technology.
The modular design of S12000 BTS and the possibility to choose between multiple
RF--combining options allows the operator to deploy the S12000 solution in a
number of different scenarios such as a high--capacity solution in cities or
alternatively enabling to provide wide--coverage with a minimum number of sites
in rural areas. The S12000 BTS indoor version is designed for protected sites, while
the outdoor version is a fully integrated BTS site with AC power supply and
extended temperature range.
1.2.2.4
e--cell BTS
The e--cell BTS is the micro--BTS from Nortel Networks with a very light and
compact design. It is quick and easy to install. The e--cell unit includes two
transceivers and can be easily extendible to a synchronized four--transceiver BTS.
It is EDGE--ready and provides an ideal solution for indoor deployment as part of
a micro cellular underlay, or for in--building coverage.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
User’s help screen
BTS18000 overview
1--6
Welcome screen
Nortel Networks Confidential
1.3
BTS18000 offer
1.3.1
BTS18000 versions
The BTS18000 is proposed in standard into two main versions:
BTS18000 indoor,
BTS18000 outdoor.
In addition to the two standard indoor and outdoor versions, the BTS18000 is
proposed in two variants:
Combo GSM/UMTS dual mode variant, proposed in indoor and outdoor
version,
MCPA variant, with increased number of TRXs per cabinet used in conjunction
with MCPA cabinet, proposed in outdoor version.
1.3.2
BTS18000 possible uses
The BTS18000, which is meant for various operating environments:
complements the S8000 or S12000 BTSs in Nortel Networks portfolio for
greenfield site deployments.
provides continuity to the S8000 and S12000 BTSs by its ability to be operated in
a synchronized co--location mode, to increase the capacity of existing S8000 or
S12000 sites.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 functionality
2--1
BTS18000 FUNCTIONALITY
2.1
GSM--UMTS dual technology proposal
The BTS18000 is designed to integrate, within the same cabinet, both
GSM/GPRS/EDGE and UMTS technologies.
This configuration is available on all GSM frequency variants (850, 900, 1800, and
1900 MHz) and on both 1900 and 2100 MHz frequency variants for UMTS. The
maximum one--cabinet configuration is GSM S333 + UMTS STSR--2.
This configuration can support up to two additional GSM extension cabinets of 18
TRX. The maximum three--cabinet configuration is GSM S15.15.15 + UMTS
STSR--2.
2.2
GSM features
The BTS18000 offers a set of features enhancing the Quality of Service and the
spectrum efficiency of the network such as:
Full support of GPRS data services.
Full support of EDGE 8PSK modulation.
Guaranteed --110 dBm dynamic single--branch receive sensitivity (GMSK
modulation) at the BTS antenna, without any tower--mounted Low Noise
Amplifier (LNA).
Improved receiver diversity gain using a Nortel Networks specific algorithm,
providing 5 dB or more diversity gain in most situations, when spatial diversity
and de--correlated antennas are used.
High output power with a 30W or 45W standard Power Amplifier (PA), and an
optional 60W High Power Amplifier.
The BTS18000 cabinet can also be used as a very high density BTS in
conjunction with an optional cabinet housing Multi Carrier Power Amplifiers
(MCPA) and TX/RX antenna combiners.
The MCPA feature allows high radio capacities using fewer RF feeders
(8--Carriers per feeder at 43 dBm) and antennas:
• without the coverage penalties of hybrid combiner solutions,
• without the frequency hopping limitations of cavity combiner solutions.
The MCPA feature leads to a S16.16.16 configuration in two BTS cabinets and
one MCPA cabinet. The BTS18000 cabinet then contains up to 27 TRX without
power amplification. This BTS configuration is ideal for urban deployment with
severe space limitations and high capacity demands without compromising radio
coverage.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
2--2
User’s help screen
BTS18000 functionality
Welcome screen
Nortel Networks Confidential
Dual--band GSM configurations with single--BCCH, built in a single or in
multiple BTS18000 cabinets.
Enhanced voice quality due to an innovative algorithm of interference
cancellation significantly reducing the end--user’s perception of errors generated
in the radio transmission.
Full RF power control range (static and dynamic).
Spectrum efficiency optimization with the support of the undisputed Nortel
Networks capacity features that provide high quality voice and data services to a
dense subscriber population, in a limited spectrum and at competitive cost.
These solutions include Fractional Frequency Reuse, Automated Cell Tiering
and Adaptive Multi Rate (AMR) support.
Best--in--class radio performance thanks to high sensitivity receivers, unique
interference cancellation and improved spatial diversity algorithms along with
high output power, providing optimum coverage and link quality for both data
and voice services.
High integration of advanced technology.
This in turn contributes to a significant reduction in required floor space, size and
equipment operating costs. This concept is adapted to stringent environmental
constraints and is leading to the best economic trade--off between initial and final
capacity.
In addition, the BTS18000 supports asymmetrical radio configurations such as
S963.
Compatibility with the S8000 and S12000 BTSs:
• through existing site synchronized co--location,
• through the possibility to re--use existing site equipment (such as an
S8000/S12000 outdoor plinth).
Industry leading transmission solution including high signaling concentration on
the Abis interface and drop--and--insert capability.
As an example, a single timeslot is only required for carrying the signaling of a
S333 BTS.
GSM/GPRS/EDGE and UMTS dual technology capabilities for operator
evolution to 3G data services.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
2.3
Welcome screen
BTS18000 functionality
2--3
GSM functions
The BTS18000 provides:
the radio interface with the mobile handsets,
the associated signal processing and the transmission interface with the Base
Station Controller (BSC).
The BTS18000 ensures the following main functions:
RF functions:
• Antenna coupling and duplexing,
• Power amplification,
• Reception, including RF 2--way receive diversity,
• Gaussian Minimum Shift Keying (GMSK) modulation/demodulation,
• 8--Phase Shift Keying (8--PSK) EDGE modulation/demodulation,
• Synthesized frequency hopping in all hybrid coupling types.
Radio channel management:
• BTS and mobile handset power control,
• Discontinuous Transmission and Voice Activity Detection (DTX/VAD), on
both uplink and downlink paths,
• Radio channel filling,
• Call setup and release,
• Mobile timing advance processing,
• Support of Enhanced Full--Rate (EFR), Full--Rate (FR), AMR Full--Rate and
AMR Half--Rate speech coding,
Signal processing:
• Channel encoding and decoding,
• Encryption (A5/2 and A5/1),
• Equalization,
• Cancellation of interference,
• Processing of radio measurements, including handover algorithms,
Interface with the BSC:
• Communication with the BSC,
• Concentration of signaling on the Abis interface (a single PCM timeslot can
concentrate signaling for up to nine transceivers),
• Multiplexing of four traffic channels on one PCM slot (each TRX needs two
PCM slots for traffic),
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
2--4
User’s help screen
BTS18000 functionality
Welcome screen
Nortel Networks Confidential
• Dynamic Abis for EDGE traffic,
• Optional optical OC--3/STM--1 connectivity.
Switching:
• Connection between the PCM links and the traffic/signaling channels,
• Management of drop--and--insert connections,
• Management of the TRX and PCM link redundancy.
Operation and Maintenance:
• High level of availability through optional duplication of switching,
synchronization and control unit (working in active/stand--by mode) and
optional N+1 redundancy for rectifiers and RM,
• Monitoring of internal and external alarms, through internal bus and alarm
loops,
• Remote configuration management from the BSC (site, sector, Abis, TRX),
• Remote software downloading.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--1
BTS18000 HARDWARE
3.1
Description of the cabinets
This section presents the BTS18000 cabinet layout for both outdoor and indoor
versions.
For the outdoor version as well as for the indoor version, the BTS18000 cabinet
includes two shelves (see Figure 5--3 of Chapter 5 for a functional view of these two
shelves). Each shelf contains:
one combiner rack,
one digital rack.
3.1.1
BTS18000 outdoor cabinet layout
The BTS18000 outdoor BTS can be housed in one or several cabinets depending
on the required capacity:
Only one cabinet is required (base cabinet), if the GSM capacity does not exceed:
• 18 TRX, in GSM--only mode,
• 9 TRX, in GSM--UMTS dual mode.
Up to two additional extension cabinets can be added. Each extension cabinet can
support up to 18 TRX.
The BTS18000 outdoor cabinet includes the following elements:
outdoor enclosure including AC Distribution Unit (ADU),
AC/DC power supply: Univity Compact Power System (UCPS),
Environmental Control Unit (ECU),
User Rack space and its associated User ICO,
back--planes and ICO: Interface Back--Plane (IBP), Digital Back--plane (DBP),
Radio InterCOnnect board (RICO),
up to two Interface Modules (IFM),
one Interface Control Module (ICM) or two ICMs (in an active/passive
configuration, also called configuration with redundancy),
up to two SPare Modules (SPM),
up to two Alarm and Bridge Modules (ABM),
up to six Radio Modules (RM),
up to six Dual Duplexer Modules (DDM) with Voltage Standing Wave Ratio
(VSWR) meter.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
User’s help screen
BTS18000 hardware
3--2
Welcome screen
Nortel Networks Confidential
Figure 3--1 presents the BTS18000 outdoor cabinet layout and situates the modules
in a fully equipped cabinet.
Figure 3--1
BTS18000 outdoor equipped cabinet with door opened (front view)
Note: The DDM modules are physically grouped into the two combiner racks.
Each digital rack consists of the association of IFM, ICM, ABM, SPM and
RM modules.
Note: IFM, ICM and SPM modules are not required in a BTS18000 extension
cabinet.
3.1.2
BTS18000 indoor cabinet layout
The BTS18000 indoor cabinet includes the following elements:
indoor enclosure,
DC breaker panel,
BTS18000 Integrated Cooling System (SICS),
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--3
back--planes and ICO: Interface Back--Plane (IBP), Digital Back--plane (DBP),
Radio InterCOnnect board (RICO),
up to two Interface Modules (IFM),
one Interface Control Module (ICM) or two ICMs (in an active/passive
configuration),
up to two SPare Modules (SPM),
up to two Alarm and Bridge Modules (ABM),
up to six Radio Modules (RM),
up to six Dual Duplexer Modules (DDM) with VSWR meter.
Figure 3--2 presents the BTS18000 indoor cabinet layout and situates the modules
in a fully equipped cabinet.
Figure 3--2
BTS18000 indoor equipped cabinet with door opened (front view)
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--4
User’s help screen
BTS18000 hardware
3.1.3
Welcome screen
Nortel Networks Confidential
Power supply (outdoor cabinet)
The outdoor cabinet provides an AC input. The AC Distribution Unit (ADU)
performs AC protection, filtering and distribution.
The UCPS power supply system delivers - 48V DC voltage from the AC input.
The UCPS includes:
the rectifiers,
the DC Distribution Unit (DDU),
the Cabinet Control Unit (CCU).
3.1.4
Cooling system
3.1.4.1
BTS18000 outdoor cabinet
The outdoor cabinet design integrates the Environmental Control Unit (ECU). This
unit is installed at the top of the cabinet.
3.1.4.2
BTS18000 indoor cabinet
The indoor cabinet design integrates the BTS18000 Indoor Cooling System (SICS).
This system is installed at the bottom of the cabinet, and accessed through an access
lift off panel.
An electronic monitoring unit controls the cooling functions of the SICS.
This unit:
senses the internal cabinet air temperature and the external ambient air
temperature,
then selects the level of environmental control required to maintain full
operational performance of the electronic equipment installed within the indoor
cabinet.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3.1.5
Physical characteristics and environmental requirements
3.1.5.1
BTS18000 outdoor cabinet
3--5
As shown in Table 3--1, the weights and dimensions of the BTS18000 outdoor
cabled cabinet allows for installations using generally available installation tools
and methods. Key construction features are:
Cabled cabinet design integrating all mechanical sub--racks and mechanical
support systems required for the installation, transport and operation of the GSM
wireless equipment.
Centralized single Environmental Control Unit (ECU), supplying standardized
cooling performance regardless of BTS configuration.
AC Distribution Unit (ADU).
Standardized AC/DC distribution system, allowing BTS minimum to maximum
configuration expansion: Univity Compact Power System (UCPS).
Standardized Radio InterCOnnection module (RICO), allowing minimum to
maximum BTS configuration expansion.
Standardized digital back--plane assembly, allowing minimum to maximum
BTS configuration expansion.
Outdoor cabinet
Height
mm
Width
mm
Depth
mm
Weight
Kg
BTS18000 pre--cabled cabinet
1500
1350
735
180
BTS18000 fully equipped cabinet
1500
1350
735
450
Table 3--1
BTS18000 outdoor dimensions and weights
The BTS18000 outdoor cabinet is designed to support an external temperature
range of --40_C to +50_C with an absolute humidity between 1 g/m3 and 36 g/m3.
The BTS18000 enclosure is designed for an outdoor environment.
Combo GSM--UMTS and MCPA variants of BTS18000 outdoor cabinet support the
same environmental conditions.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--6
User’s help screen
Welcome screen
BTS18000 hardware
3.1.5.2
Nortel Networks Confidential
BTS18000 indoor cabinet
As shown in the Table 3--2, the weight and dimensions of the BTS18000 indoor
cabled cabinet allows for installations using generally available installation tools
and methods. Key construction features are:
Cabled cabinet design integrating all mechanical sub--racks and mechanical
support systems required for the installation, transport and operation of the GSM
wireless equipment.
Centralized single low acoustic noise BTS18000 Indoor Cooling System (SICS),
supplying standardized cooling performance regardless of BTS configuration.
Standardized DC distribution system, allowing BTS minimum to maximum
configuration expansion.
Standardized Radio InterCOnnection module (RICO), allowing minimum to
maximum BTS configuration expansion.
Standardized digital back--plane assembly, allowing minimum to maximum
BTS configuration expansion.
Indoor cabinet
Height
mm
Width
mm
Depth
mm
Weight
Kg
BTS18000 fully equipped cabinet
1750
600
600
300
Table 3--2
BTS18000 indoor dimensions and weight
The BTS18000 indoor cabinet is designed to support an external temperature range
of --5_C to +45_C with an absolute humidity between 1 g/m3 and 29 g/m3.
The BTS18000 enclosure is designed for a standard indoor environment.
Combo GSM--UMTS variant of BTS18000 indoor cabinet supports the same
environmental conditions.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2
Welcome screen
BTS18000 hardware
3--7
Description of the modules
This section:
lists the modules,
introduces their function,
illustrates their front panel (including LEDs),
gives the LEDs behavior for ICM, RM and ABM,
indicates the required configuration of the ICM, DDM and TXF switches for
BTS18000 commissioning.
3.2.1
Interface Back Plane (IBP), Digital Back Plane (DBP) and Radio
InterCOnnect board (RICO)
3.2.1.1
Interface Back Plane (IBP) and Digital Back Plane (DBP)
The IBP and the DBP provide the electrical interfaces that support DC power
distribution and communication between all digital and radio modules.
All modules and some cables carrying external signals are plugged into connectors
mounted on the backplanes printed--circuit board.
IBP and DBP are common to indoor and outdoor cabinets, and are field replaceable.
3.2.1.2
Radio InterCOnnect board (RICO)
The RICO provides the electrical interfaces that support DC power distribution and
communication between all radio coupling modules and ABM, using front panel
cables.
3.2.2
Radio Module (RM)
3.2.2.1
Function
The RM is a complete GSM/GPRS/EDGE transmitter/receiver. The RM is in charge
of all processing related to the GSM TDMAs. It is designed to support three TDMA
(GSM or EDGE). It is logically equivalent to three TRXs.
The RM may operate:
on a one--sector basis (three carriers per sector, O3 mode),
on a three--sector basis (one carrier per sector, S111 mode).
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--8
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
The RM includes the following elements:
a Power Supply Unit (PSU) delivering, from the 24/48V main power supply, the
secondary supplies (27V, 3.3V, 5.7V) to the other blocks of the RM,
the RF RX board (RM RX), three dual narrowband receiver chains (main and
diversity),
the RF TX board (RM TX), three low level transmit drivers,
the RF PA board (RM PA), three Power Amplifier (PA) lines up,
the Logic Radio Module (LRM), the digital control board.
3.2.2.2
Front panel
Figure 3--3
PE/DCL/DD/0160
411--9001--160
Preliminary
RM front panel
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.2.3
Welcome screen
BTS18000 hardware
3--9
BTS18000 corporate LEDs behavior
As shown on Figure 3--4, an upper triangle--shaped red LED and a lower
rectangle--shaped green LED are used to indicate the status for the RM, as well as
for the ICM and ABM modules. See Table 3--3 for detailed status information.
Figure 3--4
Green LED
BTS18000 corporate LEDs for RM, ICM and ABM
Red LED
switched off switched off
Module status
ICM
RM
ABM
un--powered or not inserted
(default hardware value)
used
used
used
starting, BISTs in progress
used
used
used
switched off
module OK (should not be
removed)
used
used
used
blinking
switched off
switched off
blinking
blinking
or
switched off
blinking
blinking
Table 3--3
module is possibly partially
faulty
alarm status: module NOK,
must be removed and
replaced
module is being indicated
wait for ICM connection
internal downloading
ICM
TRX(s)
installation
in fault
problem
not
used
used
RM is
in fault
used
not used
not
used
not
used
used on
passive
ICM
used
used
used on
passive
ICM
not
used
used
BTS18000 corporate LEDs behavior (RM, ICM, ABM)
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
User’s help screen
Welcome screen
BTS18000 hardware
3--10
3.2.2.4
Nortel Networks Confidential
Ethernet LEDs behavior
The TX (green) and LI (amber) Ethernet LEDs are on the Ethernet connector. See
Table 3--3 for color explanations.
LED
Name
Color
Meaning
LI
Ethernet link, switched on when connection is established
TX
TX Ethernet, switched on during data transfer
Table 3--4
3.2.2.5
RM Ethernet LEDs behavior
TRX LEDs behavior
Table 3--5 describes the TRX LEDs behavior.
LED
Name
Color
Meaning
TRX
0--1--2
Amber
-- flashes during SPU cluster download
-- blinks until BSC connection, including Abis downloading
-- switched off when TRX is operational
Table 3--5
3.2.2.6
RM TRX 0--1--2 LEDs behavior
LEDs behavior at RM starting up
Table 3--6 describes the LEDs behavior at RM starting up.
RM
power
up
RM
start
up
RM
BISTs
RM
soft
start
triangle
corporate
rectangle
corporate
TRX
0--1--2
amber
amber
Table 3--6
PE/DCL/DD/0160
411--9001--160
Preliminary
RM soft
init
(1/2)
SPU
load &
start
RM soft Connection
Nominal
init
to BCF/Abis
operation
(2/2)
downloading
blinking
blinking
blinking
amber
blinking
amber blinking
LEDs behavior at RM starting up
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.3
Welcome screen
BTS18000 hardware
3--11
High Power Radio Module (HPRM)
The HPRM is a variant of the RM with only a two--TDMA capacity. This variant
shares with the RM the following elements:
the PSU,
the LRM,
the RM TX,
the RM RX.
The BTS18000 with HPRM is only available in GSM900 frequency band.
The HPRM can operate on:
one--sector basis (two carriers per sector, O2 mode),
two--sector basis (one carrier per sector, S11 mode).
Maximum configurations for BTS18000 mono--cabinet with HPRM are S444, O12
and S66.
3.2.4
Interface Control Module (ICM)
3.2.4.1
Function
The ICM is only used in the BTS18000 base cabinet. It is not present in the extension
cabinets. It is designed to manage the whole BTS18000 site in simplex
configuration.
The ICM in simplex mode covers the functions related to a complete site including:
support of drop--and--insert facilities for the PCM links with the BSC,
reference clock for the air interface, synchronized on the Abis PCM interface, a
synchronizing BTS or a GPS antenna,
GSM_TIME calculations with possible network synchronization,
switching of PCM slots,
conversion of electrical signals, from external to internal PCM data formats,
concentration of the data flow of the BTS,
configuration and supervision of all the modules.
The ICM is composed of a single board with connections on the IBP and on the front
panel.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--12
User’s help screen
BTS18000 hardware
3.2.4.2
Nortel Networks Confidential
Front panel
Figure 3--5
3.2.4.3
Welcome screen
ICM front panel
LEDs behavior
For detailed information on the BTS18000 corporate LEDs behavior, refer to
Section 3.2.2.3. Table 3--7 gives detailed information on ICM LEDs behavior. All
the LEDs are OFF when the ICM is un--powered. All the LEDs are amber during
BISTs.
LED name
PCMx
(x = 0 to 7)
Color
8 PCM status LEDs (one per PCM):
-- Green: the PCM is OK
-- Red: the PCM is in fault
-- Amber: the PCM is in test
1 GPS or external synchro status LED:
-- OFF: no external synchronization
-- Green: GPS synchronization
-- Red: bad external synchronization signal
-- Amber: master BTS synchronization
(GPS)
SYN
(synchro)
Four LEDs for synchronizing source: one out of the 8 PCMs
or external synchronization (in that case the 4 LEDs are ON)
-- see Table 3--8 --
(holdover)
One LED for synchro locked status:
-- ON on active ICM: un--locked or holdover indication
-- ON on passive ICM: un--locked indication
-- OFF: synchro is locked on external source
ACT
(activity)
ABIS
Table 3--7
PE/DCL/DD/0160
411--9001--160
Meaning
Preliminary
One LED for ICM Passive or Active Status:
-- Green: the ICM is active
-- OFF: the ICM is passive
-- Red on both ICMs: the simplex or duplex configuration
cannot be determined, both ICMs are in faulty passive state
Level--2 status with BSC:
-- ON: level--2 is OK
-- Blinking: downloading in progress
-- OFF: no Level--2 with the BSC
ICM LEDs behavior
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--13
The behavior of the four LEDs for synchronization source is described in Table 3--8.
SYNCHRO SOURCE
PCM 0
PCM 1
switched off
switched off switched off
PCM 2
switched off switched off
PCM 3
switched off switched off switched off
switched off switched off
switched off
PCM 4
switched off
switched off
PCM 5
switched off
switched off
PCM 6
switched off
PCM 7
switched off switched off switched off
external source
(GPS, master BTS)
holdover
Table 3--8
3.2.4.4
switched off switched off switched off switched off
ICM SYN LEDs behavior
LEDs behavior at active ICM starting up
The LEDs behavior, when the active ICM starts up, is as follows:
When the BTS18000 is turned on, H (holdover) and ACT (active) LEDs
switch ON.
After the Built--in Self Test (BIST) sequence, the ICM searches for
synchronizing with the PCM0 link.
When the clock source is found, H LED switches OFF and synchro source
LEDs (SYN) switch ON (see Table 3--8).
Table 3--9 describes the LEDs behavior at active ICM starting up.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--14
User’s help screen
BTS18000 hardware
Nortel Networks Confidential
ICM boot
sequence
ICM BISTs
Abis
connection
ICM
downloading
Nominal
operation
triangle
corporate
rectangle
corporate
ACT
SYN
Abis
PCMx
Table 3--9
3.2.4.5
Welcome screen
blinking
LEDs behavior at active ICM starting up
LEDs behavior at passive ICM starting up
The passive ICM can be differentiated from the active one thanks to the ACT LED
switched off. The behavior of the SYN and PCM LEDs is the same as for the active
ICM.
Table 3--10 describes the LEDs behavior at passive ICM starting up.
ICM boot
sequence
ICM BISTs
Active ICM
connection
Passive ICM
downloading
triangle
corporate
Y or
switched off
Y blinking
rectangle
corporate
J blinking
J blinking
ACT
SYN
Abis
PCMx
Table 3--10
PE/DCL/DD/0160
411--9001--160
Preliminary
Nominal
operation
LEDs behavior at passive ICM starting up
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.4.6
Welcome screen
BTS18000 hardware
3--15
Configuration of the ICM switches for commissioning
SW0--SW7 switches: one per Abis line
Figure 3--6
ICM Abis switch
The E1 or T1 mode selection is performed thanks to switch SW10 (see Table 3--13).
Refer to Table 3--11 and Table 3--12 for detailed information on E1/T1
configurations of the ICM Abis switches.
MF1
OFF
OFF
ON
ON
LB2
OFF
OFF
OFF
OFF
ON
ON
ON
ON
MF0
OFF
ON
OFF
ON
Frame Format
12--frame multi--frame (Super--Frame)
Extended Super--frame (ESF) with CRC6 check/generation
Extended Super--frame (ESF) without CRC6 check/generation
Not used
LB1
OFF
OFF
ON
ON
OFF
OFF
ON
ON
LB0
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Line Build--Out
length = 000..133ft (0.6dB
length = 133..266ft (1.2dB
length = 266..399ft (1.8dB
length = 399..533ft (2.4dB
length = 533..655ft (3.0dB
--7.5dB (DS1)
--15.0dB (DS1)
--22.5dB (DS1)
B8ZS
OFF
ON
Table 3--11
------
DSX--1) / 0.0dB (DS1)
DSX--1)
DSX--1)
DSX--1)
DSX--1)
Line code
AMI coding
B8ZS coding
ICM Abis switch -- T1 configuration
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--16
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
FDL (Facility Data--Link) and RSV are not used. Their default value is OFF.
MF1
MF0
Frame Format
OFF
OFF
Single frame
OFF
ON
Multi--frame with CRC4 decoding
ON
OFF
Multi--frame without any CRC4 decoding
ON
ON
Automatic multi--frame with CRC4 decoding
LB2
OFF
LB1
OFF
LB0
OFF
Line Build--Out is NOT used
Default value
B8ZS
Line code
OFF
HDB3 coding
ON
AMI coding (provision)
Table 3--12
ICM Abis switch -- E1 configuration
FDL (Facility Data--Link) and RSV are not used. Their default value is OFF.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--17
SW10 switch
Figure 3--7
E1/T1
ICM SW10 switch
RSV0
Frame Format
OFF
OFF
E1 mode (120 ohms)
OFF
ON
E1 mode with 75 ohms adapter
ON
--
T1 mode (100 ohms)
TEI(3)
TEI(2)
TEI(1)
TEI(0)
Site TEI coding
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
Table 3--13
ICM SW10 switch configuration
An ICM board cannot start if its TEI value is out of the range given in Table 3--13.
Factory setting is TEI equal to zero. RSV(0--2) are unused (default value is OFF).
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--18
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
SW11 switch
Figure 3--8
ISE
ICM SW11 switch
ICM for New--SEB mode
OFF
ICM in nominal mode
ON
ICM in New--SEB mode if confirmation bit is set in FPGA
BOOT/TOOLS
Processor booting mode
OFF
Require emulator probe connected
ON
Booting in Flash memory (nominal mode)
Table 3--14
ICM SW11 switch configuration
RSV(3--8) are unused (default value is OFF). Passive and active ICM must have the
same switches configuration. Otherwise, both ICM are in the ”passive partially
faulty” state: the corporate green LED is ON and the red one is blinking.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.5
Welcome screen
BTS18000 hardware
3--19
Interface Module (IFM)
The IFM is only used in the BTS18000 base cabinet. It is not present in the extension
cabinets. Its main function is to provide connectivity and secondary protection on
the PCM links.
It provides the following access for the ICM:
E1 (120 ohms) or T1 (100 ohms) connectivity on the Abis link with secondary
protection and filters (four PCM per IFM),
connectivity for an external synchronization source (synchronizing BTS or GPS
antenna),
connectivity for Abis extension and redundant ICM options.
The IFM is a passive board.
3.2.6
Spare Module (SPM)
The SPM is reserved for future use in the BTS18000 base cabinet only. It is not
present in the extension cabinets. The SPM is designed to add extra features to the
ICM without replacing the ICM hardware.
3.2.7
Alarms and Bridge Module (ABM)
One ABM is used in each BTS18000 digital rack. Therefore, a BTS18000 cabinet
contains two ABMs (even and odd).
The ABM is composed of a single board with connections on the DBP and on the
front panel.
3.2.7.1
Alarm collector function
The ABM alarm collector function performs the following operations under the
ICM control:
Detection of cabinet alarms:
• door status,
• outdoor cabinet User Rack and ADU.
Presence detection of the digital rack, combiner rack and other cabinet modules:
• digital rack modules: IFM, ICM, SPM and the three RMs,
• RF combiners: DDM, TX filter (TXF), DDM (H2) and TXF (H2),
• cabinet modules: indoor SICS, outdoor ECU and UCPS.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--20
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
Inventory of the digital rack, combiner rack and other cabinet modules:
• IFM, ICM, SPM and the three RMs, via the I2C bus,
• DDM, TXF, DDM (H2) and TXF (H2), via the pseudo I2C over RS422,
• indoor SICS and outdoor ECU,
• UCPS modules, through a dedicated protocol over RS422.
Alarm polling of the radio coupling modules, through the pseudo I2C bus over
RS422:
• Low Noise Amplifier (LNA) over--current detection in the DDMs,
• VSWR alarms and associated setting of thresholds in the DDMs and TX filters
with the VSWR option.
Alarm polling of the cooling system modules, through the pseudo I2C bus over
RS422:
• indoor SICS blowers, filter, power and control board status,
• outdoor ECU blowers, filter, damper, heater, power and control board status.
Alarm polling of the outdoor cabinet UCPS:
• AC monitoring,
• DC monitoring,
• breakers status,
• battery status.
Software management of the outdoor cabinet UCPS, through a dedicated
protocol over RS422:
• updating of the UCPS software release,
• setting up of certain parameters inside the UCPS in order to fit its
configuration to the BTS18000 cabinet and battery type,
• controlling the UCPS.
Optional external alarm detection (up to eight customer alarms per ABM).
Remote control drive (up to two remote controls per ABM).
3.2.7.2
Bridge function
The ABM assures bridge functions between several interfaces:
On one side, it manages interface with ICM (one front panel D link or two in case
of ICM redundancy),
On the other side, the bridge manages one internal E link for ABM alarm function
and three E links to the RM modules.
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.7.3
Welcome screen
BTS18000 hardware
3--21
Front panel
ETH
RI
DALI
Rst
UART
Figure 3--9
ABM front panel
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--22
User’s help screen
Welcome screen
BTS18000 hardware
3.2.7.4
Nortel Networks Confidential
ABM LEDs behavior
For detailed information on the BTS18000 corporate LEDs behavior, refer to
section 3.2.2.3.
Table 3--15 describes the ABM LEDs behavior.
LED
Name
Color
Meaning
2 LEDs for D activity
ON: when the connection to active ICM through the D
link related to the LED is correctly established
Only one of the 2 D LEDs can be ON
UART
Table 3--15
3.2.7.5
ON: UART activity (reserved for future use)
ABM LEDs behavior
LEDs behavior at ABM starting up
Table 3--16 describes the LEDs behavior at ABM starting up.
ABM boot ABM
sequence BIST
Active ICM
connection
ABM
downloading
Nominal
operation
triangle
corporate
Y or
switched off
Y blinking
rectangle
corporate
J blinking
J blinking
Table 3--16
LEDs behavior at ABM starting up
Note: External alarms do not impact the ABM corporate LEDs management
(these LEDs only indicate ABM board alarms).
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
3.2.8
Welcome screen
BTS18000 hardware
3--23
Dual Duplexer Module (DDM) and Transmit Filter (TXF)
The operator can use different types of couplers to couple the PAs to the antennas
and to combine the RX and TX paths:
duplexers,
transmit filters,
hybrid combiners.
These couplers can be found in the following BTS18000 modules:
DDM or DDM with optional H2 coupling, both including an optional VSWR
meter,
TXF or TXF with optional H2 coupling, both including an optional VSWR
meter.
3.2.8.1
Dual Duplexer Module (DDM)
The DDM allows to share TX and RX signals on a same antenna. The DDM is aimed
at providing:
TX filtering (noise suppression),
RX filtering (noise suppression),
TX to RX isolation,
front end low noise amplification for the receive chain.
Front panel
Figure 3--10
DDM front panel (with H2 coupling option)
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--24
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
DDM LEDs description
Figure 3--11
DDM LEDs and switches details
DDM LEDs behavior
Three LEDs are located on the DDM font panel in order to monitor DDM internal
alarm:
one LED is dedicated to LNAs high/low consumption alarm,
two LEDs are dedicated to VSWR meter:
• one for antenna 1 port,
• one for antenna 2 port.
Table 3--17 describes the DDM LEDs behavior.
LED Name
Color
LNA
ON when LNA is enabled
VSWR1
Red: Port 1 VSWR alarm level 3
Amber: Port 1 VSWR alarm level 2
OFF: no alarm or level 1
VSWR2
Red: Port 2 VSWR alarm level 3
Amber: Port 2 VSWR alarm level 2
OFF: no alarm or level 1
Table 3--17
PE/DCL/DD/0160
411--9001--160
Preliminary
Meaning
DDM LEDs behavior
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--25
Configuration of the DDM switches for commissioning
Two four--position rotate switches are located on the DDM front panel (see
Figure 3--11).
These switches must be positioned on site:
The hybrid configuration switch is used to inform the system about the use of the
two 2--way hybrid (by--passed or not).
Table 3--18 gives the switch position meaning.
Hybrid configuration switch
Switch position
DDM with two hybrids
DDM with hybrid 1 connected
DDM with hybrid 2 connected
DDM without hybrid
Table 3--18
DDM switches configuration
The VSWR switch allows modifying, on site, the VSWR meter thresholds on
both antenna ports. The three first positions (positions 0, 1 and 2) are used to
offset VSWR thresholds of respectively 0, 2 or 4 dB.
The fourth position (test position) checks that the three LEDs operate correctly.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--26
User’s help screen
BTS18000 hardware
3.2.8.2
Welcome screen
Nortel Networks Confidential
Transmit Filter (TXF)
The TXF is used, as a complement of the DDM, each time extra transmit capacity
is required without need of receive capacity. It allows direct connection from the
RM PA output to the antenna.
The TXF only filters the signal transmitted from the PA to the antenna and does not
provide the reception path.
Front panel
Figure 3--12
TXF front panel (with H2 coupling option)
TXF LEDs behavior
Two LEDs are located on the TXF font panel in order to monitor TXF alarm:
one LED is dedicated to DC power status,
one LED is dedicated to VSWR meter.
Table 3--19 describes the TXF LEDs behavior.
LED Name
Color
Power
ON when TX filter is powered on
VSWR
Red: VSWR alarm level 3
Amber: VSWR alarm level 2
OFF: no alarm or level 1
Table 3--19
PE/DCL/DD/0160
411--9001--160
Preliminary
Meaning
TXF LEDs behavior
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
BTS18000 hardware
3--27
Configuration of the TXF switches for commissioning
Two switches are located on the TXF front panel (see Figure 3--12). These switches
must be positioned on site:
The hybrid configuration two--position switch is used to inform the system about
the use of the hybrid (by--passed or not).
Table 3--20 gives the switch position meaning.
Hybrid configuration switch
Switch position
TXF with hybrid
TXF without hybrid
Table 3--20
TXF switches configuration
The VSWR four--position switch allows modifying, on site, the VSWR meter
thresholds on both antenna ports. The three first positions (positions 0, 1 and 2)
are used to offset VSWR thresholds of respectively 0, 2 or 4 dB.
The fourth position (test position) checks that the two LEDs operate correctly.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
3--28
User’s help screen
BTS18000 hardware
Welcome screen
Nortel Networks Confidential
PAGE INTENTIONALLY LEFT BLANK
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
MCPA BTS18000 configurations
8--1
MCPA BTS18000 CONFIGURATIONS
8.1
MCPA BTS18000 overview
The Nortel Networks solution for a high capacity, high output power GSM BTS site
is composed of:
up to two dedicated BTS18000 cabinets, named MCPA BTS18000 cabinets.
This MCPA version of BTS18000 cabinet is an adaptation of standard outdoor
version with a capacity of up to 27 TRXs per cabinet. This adaptation is
factory--performed.
one ancillary MCPA cabinet.
8.2
MCPA BTS18000 hardware
8.2.1
Description of the MCPA BTS18000 outdoor cabinet
The MCPA BTS18000 cabinet is the BTS18000 outdoor cabinet equipped to drive
a MCPA cabinet. It includes the following elements:
modified outdoor enclosure,
AC/DC power supply: Univity Compact Power System (UCPS),
Environmental Control Unit (ECU),
User Rack space and its associated User ICO,
back--planes and ICO: Interface Back--Plane (IBP), Digital Back--plane (DBP),
Radio InterCOnnect board (RICO),
up to two Interface Modules (IFM),
one Interface Control Module (ICM) or two ICMs (in an active/passive
configuration),
up to two SPare Modules (SPM),
up to three Alarm and Bridge Modules (ABM), including:
• the standard even and odd ABMs,
• a new ABM called neutral,
up to nine MCPA Radio Modules (MRM),
up to three low power 3:1 TX combiners,
up to three double 1:3 RX splitters.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
8--2
User’s help screen
MCPA BTS18000 configurations
Welcome screen
Nortel Networks Confidential
Figure 8--1 presents the MCPA BTS18000 outdoor cabinet layout and situates the
modules in a fully equipped cabinet.
Figure 8--1
PE/DCL/DD/0160
411--9001--160
MCPA BTS18000 outdoor equipped cabinet with door opened (front view)
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Welcome screen
MCPA BTS18000 configurations
8.2.2
Description of the MCPA BTS18000 specific modules
8.2.2.1
MCPA Radio Module (MRM)
8--3
The MRM is a depopulated version of the RM, only used in O3 mode. The MRM
shares with the RM the following components:
LRM,
RM TX,
RM RX,
PSU.
In MRM, the three PA boards are replaced by a unique board called TX booster. The
TX booster main functions are:
Amplification.
The TX booster provides extra amplification to the RM TX output (one per TX
chain).
Power regulation.
The TX booster provides an output power detector on each RF chain, in order to
maintain constant the output power of each chain, with the same Automatic
Level Control (ALC) loops as the standard RM.
RF combining.
The TX booster incorporates a transmit RF combiner 3:1, in order to deliver
multi--carrier signals on a unique TX output. The MRM output power is 4dBm
+/--0.5dB per carrier.
Compared to the RM, power/digital and RF RX interfaces remain unchanged.
Figure 8--2 presents the MRM front panel.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
8--4
User’s help screen
MCPA BTS18000 configurations
Figure 8--2
Welcome screen
Nortel Networks Confidential
MRM front panel
As shown on Figure 8--3, an upper triangle--shaped red LED and a lower
rectangle--shaped green LED are used to indicate the status for the MRM, as well
as for the ICM and ABM modules. See Table 8--1 for detailed status information.
Figure 8--3
PE/DCL/DD/0160
411--9001--160
Preliminary
BTS18000 corporate LEDs for MRM, ICM and ABM
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
Green LED
MCPA BTS18000 configurations
Red LED
switched off switched off
8--5
Module status
ICM
MRM
ABM
un--powered or not inserted
(default hardware value)
used
used
used
starting, BISTs in progress
used
used
used
switched off
module OK (should not be
removed)
used
used
used
blinking
switched off
switched off
blinking
blinking
or
switched off
blinking
blinking
Table 8--1
8.2.2.2
Welcome screen
module is possibly partially
faulty
ICM
TRX(s)
installation
in fault
problem
not
used
used
MRM is
in fault
used
not used
not
used
not
used
used on
passive
ICM
used
used
used on
passive
ICM
not
used
used
alarm status: module NOK,
must be removed and
replaced
module is being indicated
wait for ICM connection
internal downloading
BTS18000 corporate LEDs behavior (MRM, ICM, ABM)
3:1 TX combiner
The 3:1 TX combiner allows to combine up to nine transmit signals from the three
MRM TX outputs to one MCPA input. This combiner is a passive module.
The RF interfaces are:
for the TX output port, one QN 50 ohms connector,
for the TX inputs ports, three QN 50 ohms connectors.
8.2.2.3
Double 1:3 RX splitter
The double 1:3 splitter allows to split two receive signals (main and diversity) from
the MCPA cabinet Duplexer Low Noise Amplifier (DLNA). This splitter can feed
three MRMs RX inputs. This splitter is a passive module.
The RF interfaces are:
for the RX input ports, two QMA 50 ohms connectors,
for the RX outputs ports, six QMA 50 ohms connectors.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
User’s help screen
MCPA BTS18000 configurations
8--6
8.3
Welcome screen
Nortel Networks Confidential
MCPA cabinet
The MCPA cabinet includes up to:
three 2--way MCPA racks,
six DLNAs with VSWR.
The MCPA cabinet is responsible for:
amplifying the transmit composite signals coming from the MCPA BTS18000
cabinet, in the GSM1900 transmit band (1930--1990 MHz).
supplying the MCPA BTS18000 cabinet with the receive composite signals, in
the GSM1900 receive band (1850--1910 MHz).
assuring antenna RF combining:
• dual antenna connection for transmit and receive main and diversity,
• three--sector operation.
In addition, the MCPA cabinet is independent from the MCPA BTS18000 cabinet
in terms of power supply and cooling system.
8.3.1
MCPA rack overview
The association of two MCPA basic modules constitutes a 2--way rack. Each MCPA
rack is always dedicated to only one sector.
All the carriers need to be combined to constitute a composite multi--carrier signal
that feed one MCPA rack input. The MCPA amplifies this composite signal.
Duplexer coupling is used for the antenna access. The duplexer manages:
one transmit path, that can be feed only by one MCPA rack output,
up to two receive paths.
A LNA is integrated close to the duplexer, in order to amplify reception chains to
the MRM.
The MCPA rack main features are:
frequency of operation: 1930--1990 MHz,
instantaneous bandwidth of operation: 20 MHz,
nominal gain: 51.5 dB,
gain variations (all conditions): +/-- 0.7 dB,
maximum composite output power: 218W (2 ways).
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
8.3.2
Welcome screen
MCPA BTS18000 configurations
8--7
DLNA module overview
The DLNA is design as a Field Replaceable Unit (FRU). The DLNA provides:
duplexed antenna connection for the whole system in transmit and receive
GSM1900 band (TX 1930--1990 MHz, RX 1850--1910 MHz),
transmit filtering and receive filtering,
proper isolation between RX and TX frequency band,
front end low noise amplification for the receive path.
The DLNA provides one RX path with two outputs. It also provides one transmit
input. One DLNA is used for main receive path and another one is used for diversity
receive path.
All MCPA BTS18000 configurations require six DLNAs. Each DLNA is connected
to one I2C bus. The DLNAs are supervised by the even and odd ABMs of the MCPA
BTS18000 base cabinet. Even if present, the MCPA BTS18000 extension cabinet
does not manage any DLNA.
The DLNAs are powered by the MCPA cabinet energy system.
8.3.2.1
RF interfaces
The RF interfaces are:
one RF antenna connector (50 Ohms 1850--1990 MHz),
one TX input (50 Ohms 1930--1990 MHz),
two RX outputs (50 Ohms 1850--1910 MHz).
8.3.2.2
Digital interface
The DLNA interfaces, for the digital part, with the ABM module of the MCPA
BTS18000 cabinet. The DLNA provides the ABM (even or odd) with the following
information:
module presence detection,
inventory data,
VSWR alarms level 1, 2 and 3,
LNA high/low current consumption alarm.
The connection is performed through the RICO interconnect board, via I2C bus.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
8--8
User’s help screen
Welcome screen
MCPA BTS18000 configurations
8.3.3
Nortel Networks Confidential
DLNA RF features
The DLNA main RF features are:
frequency of operation: TX 1930--1990MHz, RX 1850--1910MHz,
transmit loss: 0.7 dB typ. 1.2 dB maximum,
receive path gain: 44 dB,
receive path gain variations: +/-- 1 dB all conditions,
receive path noise figure: 2 dB typ. 2.5 dB maximum,
receive path input compression point: - 16 dBm minimum,
receive path input IP3: - 8 dBm minimum,
isolation transmit/receive: greater than 105 dB.
8.3.4
VSWR meter
The DLNA is equipped with a VSWR meter in order to control matching of the
antenna path. This VSWR meter is used to supervise the connection between DLNA
antenna connector and antenna.
The VSWR meter measures the voltage standing wave ratio and compares it to three
pre--defined thresholds. These thresholds correspond to three levels of alarm that
are reported to the MCPA BTS18000 cabinet through the I2C interface (see
Table 8--2).
I2C
address
Priority
8.0dB ± 2.25dB 10.0dB ± 2.5dB
111
critical
11.5dB ± 3.0dB 13.5dB ± 3.5dB
011
minor
12.0dB ± 3.0dB 14.0dB ± 3.5dB 16.0dB ± 4.0dB
001
minor
Alarm
0dB
level 3
6.0dB ± 2.0dB
level 2
9.5dB ± 2.5dB
level 1
Table 8--2
PE/DCL/DD/0160
411--9001--160
Preliminary
2dB
4dB
DLNA alarms levels and priority
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
8.3.5
Welcome screen
MCPA BTS18000 configurations
8--9
MCPA cabinet alarm monitoring
The MCPA BTS18000 is in charge of MCPA cabinet alarm monitoring. Each
MCPA BTS18000 cabinet contains up to three ABMs:
even ABM,
odd ABM,
neutral ABM.
8.3.5.1
MCPA cabinet alarms
Those alarms are recovered by the neutral ABM of the MCPA BTS18000 base
cabinet, through DALI links.
8.3.5.2
MCPA alarms
Those alarms are recovered:
by the neutral ABM of the MCPA BTS18000 base cabinet, through DALI links,
for up to three MCPA racks,
by the neutral ABM of the MCPA BTS18000 extension cabinet, through DALI
links, for the three additional MCPA racks.
8.3.5.3
DLNA alarms
Those alarms, including VSWR alarms (level 1, 2 and 3), are recovered:
by the even ABM of the MCPA BTS18000 base cabinet, through I2C links, for
DLNA main,
by the odd ABM of the MCPA BTS18000 base cabinet, through I2C links, for
DLNA diversity.
Figure 8--4 and Figure 8--5 illustrate the digital alarms/inventory connections
between the MCPA BTS18000 and the MCPA cabinet.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
8--10
User’s help screen
Welcome screen
MCPA BTS18000 configurations
Nortel Networks Confidential
26
BTS18000 main cabinet
26
ABM neutral
ABM “even”
26
Cabinet
alarms
DLNA 0
main
MCPA 0
RICO board
ABM “odd”
DLNA 1
diversity
DLNA 2
main
MCPA 2
DLNA 3
diversity
DLNA 4
main
MCPA 4
I2C link DLNA diversity
I2C link DLNA main
DALI link MCPA/cabinet
Figure 8--4
PE/DCL/DD/0160
411--9001--160
Preliminary
MCPA cabinet
DLNA 5
diversity
MCPA BTS18000 / MCPA cabinet digital links overview
(configuration with three MCPA racks)
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks
Front page of manual
User’s help screen
Nortel Networks Confidential
MCPA BTS18000 configurations
ABM neutral
BTS18000 ext cabinet
Welcome screen
8--11
26
26
BTS18000 main cabinet
26
ABM neutral
ABM “even”
26
Cabinet
alarms
DLNA 0
main
MCPA 0
RICO board
ABM “odd”
DLNA 1
diversity
MCPA 1
DLNA 2
main
MCPA 2
DLNA 3
diversity
MCPA 3
DLNA 4
main
MCPA 4
I2C link DLNA diversity
I2C link DLNA main
DALI link MCPA/cabinet
DALI link MCPA
DLNA 5
diversity
MCPA 5
MCPA cabinet
Figure 8--5
MCPA BTS18000 / MCPA cabinet digital links overview
(configuration with six MCPA racks)
Note: In addition, as in standard configurations, the even ABM of each cabinet is
in charge of cooling and power system and common alarms of MCPA
BTS18000 cabinet.
The RICO board of each MCPA BTS18000 cabinet is powered (3.3V) by
the neutral ABM of each cabinet.
Copyright E 2002--2004 Nortel Networks
BTS18000 Reference Manual
Front page of manual
8--12
User’s help screen
MCPA BTS18000 configurations
Welcome screen
Nortel Networks Confidential
PAGE INTENTIONALLY LEFT BLANK
PE/DCL/DD/0160
411--9001--160
Preliminary
15.01/EN October 2004 Copyright E 2002--2004 Nortel Networks

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2004:11:09 11:56:23+01:00
Create Date                     : 2004:10:04 18:06:05+02:00
Page Count                      : 66
Has XFA                         : No
About                           : uuid:b9293b1e-06b2-4542-942d-dc522a02f7a5
Producer                        : Acrobat Distiller 6.0 (Windows)
Mod Date                        : 2004:11:09 11:56:23+01:00
Creation Date                   : 2004:10:04 18:06:05+02:00
Author                          : frederic.blin
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2004:11:09 11:56:23+01:00
Document ID                     : uuid:ddeae267-a3da-4629-8f53-a0052a40307d
Format                          : application/pdf
Title                           : v160pdg
Creator                         : frederic.blin
EXIF Metadata provided by EXIF.tools
FCC ID Filing: AB6BTS18000MCPA

Navigation menu