Avaya Canada NTHV45AA Wireless Link Maintenance Tool User Manual APPENDIX B HANDHELD OPERATION

Avaya Canada Corporation Wireless Link Maintenance Tool APPENDIX B HANDHELD OPERATION

Operations Manual

  APPENDIX B – HANDHELD OPERATION  1.  Press <enter> to start handheld.  2.  Handheld displays “enter address”  3.  Enter address and press <enter>.  4.  If ODU responds, asterisk goes on and message “link available” displays.  5.  If ODU does not respond, message “no response. <enter> again.” Asterisk is off. The <enter> button can be pressed again without going back to entering the address. This allows the user to move around until a good link is established.  6.  If link is available, pressing <menu> gets the “status” menu. Up/down arrows allow scrolling from “status” to “control”, etc.  7.  Pressing <enter> will bring up the first data item within the sub-menus. Up/down arrows allow item scrolling.  8.  At each sub-menu item, pressing <enter> will interrogate ODU for a new data item update. If data was not successfully received, the asterisk will extinguish. Asterisk will go on if data is received. Asterisk should be constant.  9.  Data will not be automatically updated. New data is received only after each press of the <enter> button. This includes RSSI and BER.
     APPENDIX C – HANDHELD TRANSMISSION DATA FORMAT   MENU COMMANDTx Freq S1 S2 S3 S4 31 07 CSRx Freq S1 S2 S3 S4 32 07 CSTx Power S1S2S3S43307CSFAW S1S2S3S43407CSCapacity S1 S2 S3 S4 35 07 CSCable Length S1 S2 S3 S4 36 07 CSLine Code S1 S2 S3 S4 37 07 CSTrib on/off S1S2S3S43807CSMute on/off S1S2S3S43D07CSStatus Local loopback S1 S2 S3 S4 40 07 CSRF Loopback S1 S2 S3 S4 41 07 CSRemote Loopback S1 S2 S3 S4 42 07 CSTx Freq Range S1 S2 S3 S4 4A 07 CSRx Freq Range S1 S2 S3 S4 4B 07 CSRSSI S1 S2 S3 S4 4E 07 CSTemperature S1S2S3S44F07CSBlock Error Count S1 S2 S3 S4 50 07 CSSummary Alarms S1 S2 S3 S4 51 07 CSTx Freq S1 S2 S3 S4 00 0B VD VD VD VD CSRx Freq S1 S2 S3 S4 01 0B VD VD VD VD CSPower S1S2S3S40208VDCSLocalFAW S1S2S3S40308VDCSControl Capacity S1 S2 S3 S4 04 08 VD CSCable Length S1 S2 S3 S4 05 08 VD CSLine Code S1 S2 S3 S4 06 08 VD CSTributary on/off S1 S2 S3 S4 07 08 VD CSFar Far Line Code S1 S2 S3 S4 21 08 VD CSControl Far Trib on/off S1 S2 S3 S4 22 08 VD CSLink Freqs S1S2S3S42C08VDCSLink Link Tx Power S1 S2 S3 S4 2D 08 VD CSControlLink FAW S1S2S3S42E08VDCSLink Capacity S1 S2 S3 S4 2F 08 VD CSPEC S1 S2 S3 S4 44 07 CSProd. Rel. Ver. S1 S2 S3 S4 47 07 CSInventorySerial No. S1S2S3S44807CSDSP SW Ver. S1 S2 S3 S4 4D 07 CSODU SW Ver. S1 S2 S3 S4 4C 07 CSSet Mute S1 S2 S3 S4 08 07 CSTest Set Local Loopbk S1 S2 S3 S4 10 07 CSSet RF Loopback S1 S2 S3 S4 11 07 CSSet Rem Loopbk S1 S2 S3 S4 12 07 CSPower OffHandheld ContrastSoftware Ver. No TransmissionDATANo TransmissionNo Transmission
    Notes:  S1 through S4 vary according to binary value of serial number entered at handheld.   VD indicates data that varies according to data entered at handheld keypad.   CS indicates checksum value.   All Byte values in hex   Each byte includes one start bit, 8 data bits, one parity bit, one stop bit.       APPENDIX D – ODU TRANSMISSION DATA FORMAT    S1 – S4 contains the ODU address VD = variable data FS = field separator byte COMMAND RECEIVEDGet Tx Frequency S1 S2 S3 S4 31 10 VD VD VD VD FS VD VD VD VD CSGet Rx Frequency S1 S2 S3 S4 32 10 VD VD VD VD FS VD VD VD VD CSGet Tx Power S1S2S3S4 33 0A VD FS VD CSGet FAW S1S2S3S4 34 0A VD FS VD CSGet Capacity S1 S2 S3 S4 35 0A VD FS VD CSGet Cable Length S1 S2 S3 S4 36 0C VD VD FS VD VD CSGet Line Code S1 S2 S3 S4 37 0A VD FS VD CSGet Tributary on/off S1 S2 S3 S4 38 0A VD FS VD CSGet Mute on/off S1 S2 S3 S4 3D 0A VD FS VD CSGet Local Loopback S1 S2 S3 S4 40 0A VD FS VD CSGet RF loopback S1 S2 S3 S4 41 0A VD FS VD CSGet Rem loopback S1 S2 S3 S4 42 0A VD FS VD CSGet Tx Freq Range S1S2S3S44A18 VDVDVD VD VD VDVDVDFS VD VDVDVDVDVDVDVDCSGet Rx Freq Range S1 S2 S3 S4 4B 18 VD CS VD VD VD VD VD VD FS VD VD VD VD VD VD VD VD CSGet RSSI S1 S2 S3 S4 4E 0A VD FS VD CSGet Temperature S1 S2 S3 S4 4F 0A VD FS VD CS    Get Block error count S1 S2 S3 S4 50 0C VD VD FS VD VD CSGet Summary alarms S1 S2 S3 S4 51 10 VD VD VD VD FS VD VD VD VD CSSet Far End Line code S1 S2 S3 S4 21 08 VD CSSet Far End Trib on/off S1 S2 S3 S4 22 08 VD CSSet link freqs S1S2S3S42C 0F VD VD VD VD VD VD VDVD CSSet link Tx power S1 S2 S3 S4 2D 08 VD CSSet link FAW S1S2S3S42E 08 VD CSSet link capacity S1 S2 S3 S4 2F 08 VD CSGet PEC S1 S2 S3 S4 44 20 VD VD VD VD VD VD VD VD VD VD VD VD FS VD VD VD VD VD VD VD VD VD VD VD VD CSGet Prod Rel Ver S1S2S3S447 20 VDVDVD VD VD VDVDVDVDVD VDVDFSVDVDVDVDVDVDVDVDVDVDVDVDCSGet Serial No. S1S2S3S448 20 VDVDVD VD VD VDVDVDVDVD VDVDFSVDVDVDVDVDVDVDVDVDVDVDVDCSGet Tx freq range S1S2S3S44A 18 VDVDVD VD VD VDVDVDFS VD VDVDVDVDVDVDVDCSGet Rx Freq range S1 S2 S3 S4 4B 18 VD VD VD VD VD VD VD VD FS VD VD VD VD VD VD VD VD CSGet ODU SW ver. S1 S2 S3 S4 4C 0C VD VD FS VD VD CSGet DSP SW Ver S1 S2 S3 S4 4D 0A VD FS VD CSSet Tx Freq S1 S2 S3 S4 00 0B VD VD VD VD CSSet Rx Freq S1 S2 S3 S4 01 0B VD VD VD VD CSSet Tx Power S1 S2 S3 S4 02 08 VD CSSet FAW S1S2S3S4 03 08 VD CSSet Capacity S1 S2 S3 S4 04 08 VD CSSet Cable length S1 S2 S3 S4 05 09 VD VD CSSet Line code S1 S2 S3 S4 06 08 VD CSSet Tributary on/off S1 S2 S3 S4 07 08 VD CSset mute on/off S1 S2 S3 S4 0C 08 VD CSSet local loopback S1 S2 S3 S4 10 08 VD CSSet RF Loopback S1 S2 S3 S4 11 08 VD CSSet Remote loopback S1 S2 S3 S4 12 08 VD CSDATA
  CS = packet checksum All Byte values in hex. Each byte includes one start bit, 8 data bits, one parity bit, one stop bit. Data is transmitted only after receiving a request from handheld.