Avaya Canada NTHV45AA Wireless Link Maintenance Tool User Manual APPENDIX B HANDHELD OPERATION

Avaya Canada Corporation Wireless Link Maintenance Tool APPENDIX B HANDHELD OPERATION

Operations Manual

Download: Avaya Canada NTHV45AA Wireless Link Maintenance Tool User Manual APPENDIX B          HANDHELD OPERATION
Mirror Download [FCC.gov]Avaya Canada NTHV45AA Wireless Link Maintenance Tool User Manual APPENDIX B          HANDHELD OPERATION
Document ID132633
Application ID5wu4AjLct0dzorebznl1bA==
Document DescriptionOperations Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize1.58kB (19772 bits)
Date Submitted2001-01-15 00:00:00
Date Available2001-01-15 00:00:00
Creation Date2001-01-12 07:24:24
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2001-01-12 07:24:36
Document TitleAPPENDIX B – HANDHELD OPERATION
Document CreatorMicrosoft Word 9.0
Document Author: Denis Lalonde

APPENDIX B – HANDHELD OPERATION
1. Press  to start handheld.
2. Handheld displays “enter address”
3. Enter address and press .
4. If ODU responds, asterisk goes on and message “link available” displays.
5. If ODU does not respond, message “no response.  again.” Asterisk is off. The 
button can be pressed again without going back to entering the address. This allows the user
to move around until a good link is established.
6. If link is available, pressing  gets the “status” menu. Up/down arrows allow scrolling
from “status” to “control”, etc.
7. Pressing  will bring up the first data item within the sub-menus. Up/down arrows allow
item scrolling.
8. At each sub-menu item, pressing  will interrogate ODU for a new data item update. If
data was not successfully received, the asterisk will extinguish. Asterisk will go on if data is
received. Asterisk should be constant.
9. Data will not be automatically updated. New data is received only after each press of the
 button. This includes RSSI and BER.
APPENDIX C – HANDHELD TRANSMISSION DATA FORMAT
MENU
COMMAND
Tx Freq
Rx Freq
Tx Power
FAW
Capacity
Cable Length
Line Code
Trib on/off
Mute on/off
Local loopback
RF Loopback
Remote Loopback
Tx Freq Range
Rx Freq Range
RSSI
Temperature
Block Error Count
Summary Alarms
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
31
32
33
34
35
36
37
38
3D
40
41
42
4A
4B
4E
4F
50
51
DATA
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
Local
Control
Tx Freq
Rx Freq
Power
FAW
Capacity
Cable Length
Line Code
Tributary on/off
S1
S1
S1
S1
S1
S1
S1
S1
S2
S2
S2
S2
S2
S2
S2
S2
S3
S3
S3
S3
S3
S3
S3
S3
S4
S4
S4
S4
S4
S4
S4
S4
00
01
02
03
04
05
06
07
0B
0B
08
08
08
08
08
08
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
CS
CS
CS
CS
CS
CS
Far
Control
Far Line Code
Far Trib on/off
S1
S1
S2
S2
S3
S3
S4
S4
21
22
08
08
VD
VD
CS
CS
Link
Control
Link Freqs
Link Tx Power
Link FAW
Link Capacity
S1
S1
S1
S1
S2
S2
S2
S2
S3
S3
S3
S3
S4
S4
S4
S4
2C
2D
2E
2F
08
08
08
08
VD
VD
VD
VD
CS
CS
CS
CS
PEC
Prod. Rel. Ver.
Inventory Serial No.
DSP SW Ver.
ODU SW Ver.
S1
S1
S1
S1
S1
S2
S2
S2
S2
S2
S3
S3
S3
S3
S3
S4
S4
S4
S4
S4
44
47
48
4D
4C
07
07
07
07
07
CS
CS
CS
CS
CS
Set
Set
Set
Set
S1
S1
S1
S1
S2
S2
S2
S2
S3
S3
S3
S3
S4
S4
S4
S4
08
10
11
12
07
07
07
07
CS
CS
CS
CS
Status
Test
Mute
Local Loopbk
RF Loopback
Rem Loopbk
Power Off
Handheld Contrast
Software Ver.
No Transmission
No Transmission
No Transmission
VD
VD
VD
VD
CS
CS
Notes: S1 through S4 vary according to binary value of serial number entered at handheld.
VD indicates data that varies according to data entered at handheld keypad.
CS indicates checksum value.
All Byte values in hex
Each byte includes one start bit, 8 data bits, one parity bit, one stop bit.
APPENDIX D – ODU TRANSMISSION DATA FORMAT
COMMAND RECEIVED
Get Tx Frequency
Get Rx Frequency
Get Tx Power
Get FAW
Get Capacity
Get Cable Length
Get Line Code
Get Tributary on/off
Get Mute on/off
Get Local Loopback
Get RF loopback
Get Rem loopback
Get Tx Freq Range
Get Rx Freq Range
Get RSSI
Get Temperature
Get Block error count
Get Summary alarms
Set Far End Line code
Set Far End Trib on/off
Set link freqs
Set link Tx power
Set link FAW
Set link capacity
Get PEC
Get Prod Rel Ver
Get Serial No.
Get Tx freq range
Get Rx Freq range
Get ODU SW ver.
Get DSP SW Ver
Set Tx Freq
Set Rx Freq
Set Tx Power
Set FAW
Set Capacity
Set Cable length
Set Line code
Set Tributary on/off
set mute on/off
Set local loopback
Set RF Loopback
Set Remote loopback
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
31
32
33
34
35
36
37
38
3D
40
41
42
4A
4B
4E
4F
50
51
21
22
2C
2D
2E
2F
44
47
48
4A
4B
4C
4D
00
01
02
03
04
05
06
07
0C
10
11
12
10
10
0A
0A
0A
0C
0A
0A
0A
0A
0A
0A
18
18
0A
0A
0C
10
08
08
0F
08
08
08
20
20
20
18
18
0C
0A
0B
0B
08
08
08
09
08
08
08
08
08
08
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
FS
FS
FS
VD
FS
FS
FS
FS
FS
FS
VD
CS
FS
FS
VD
VD
CS
CS
VD
CS
CS
CS
VD
VD
VD
VD
VD
VD
FS
VD
VD
CS
CS
CS
VD
CS
CS
CS
CS
CS
CS
S1 – S4 contains the ODU address
VD = variable data
FS = field separator byte
FS
FS
DATA
VD VD VD VD CS
VD VD VD VD CS
VD
CS
VD
VD
VD VD VD FS
VD VD VD FS
VD
FS
CS
VD VD VD VD CS
VD
VD
VD VD VD CS
VD
VD
VD
VD
VD
VD
CS
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
CS
VD
VD
VD
VD
VD
FS
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
FS
VD
VD
VD
CS
CS
CS
VD
CS
CS
CS
CS
CS
CS
VD
VD
CS
CS
VD
VD
VD
VD
VD
VD
VD
VD
FS
VD
VD
VD
CS
CS
CS
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
FS
FS
VD
VD
VD
VD
VD
VD
VD
VD VD VD VD VD VD VD CS
VD VD VD VD VD VD VD CS
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
FS
FS
FS
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD VD VD VD VD VD VD VD CS
VD VD VD VD VD VD VD VD CS
VD VD VD VD VD VD VD VD CS
CS
CS
CS = packet checksum
All Byte values in hex.
Each byte includes one start bit, 8 data bits, one parity bit, one stop bit.
Data is transmitted only after receiving a request from handheld.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Producer                        : Acrobat Distiller 4.05 for Windows
Creator                         : Microsoft Word 9.0
Modify Date                     : 2001:01:12 07:24:36-07:00
Author                          : Denis Lalonde
Title                           : APPENDIX B – HANDHELD OPERATION
Create Date                     : 2001:01:12 07:24:24
Page Count                      : 4
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools
FCC ID Filing: AB6NTHV45AA

Navigation menu